1
|
Walter A, Hoegen-Saßmannshausen P, Stanic G, Rodrigues JP, Adeberg S, Jäkel O, Frank M, Giske K. Segmentation of 71 Anatomical Structures Necessary for the Evaluation of Guideline-Conforming Clinical Target Volumes in Head and Neck Cancers. Cancers (Basel) 2024; 16:415. [PMID: 38254904 DOI: 10.3390/cancers16020415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 12/28/2023] [Accepted: 01/08/2024] [Indexed: 01/24/2024] Open
Abstract
The delineation of the clinical target volumes (CTVs) for radiation therapy is time-consuming, requires intensive training and shows high inter-observer variability. Supervised deep-learning methods depend heavily on consistent training data; thus, State-of-the-Art research focuses on making CTV labels more homogeneous and strictly bounding them to current standards. International consensus expert guidelines standardize CTV delineation by conditioning the extension of the clinical target volume on the surrounding anatomical structures. Training strategies that directly follow the construction rules given in the expert guidelines or the possibility of quantifying the conformance of manually drawn contours to the guidelines are still missing. Seventy-one anatomical structures that are relevant to CTV delineation in head- and neck-cancer patients, according to the expert guidelines, were segmented on 104 computed tomography scans, to assess the possibility of automating their segmentation by State-of-the-Art deep learning methods. All 71 anatomical structures were subdivided into three subsets of non-overlapping structures, and a 3D nnU-Net model with five-fold cross-validation was trained for each subset, to automatically segment the structures on planning computed tomography scans. We report the DICE, Hausdorff distance and surface DICE for 71 + 5 anatomical structures, for most of which no previous segmentation accuracies have been reported. For those structures for which prediction values have been reported, our segmentation accuracy matched or exceeded the reported values. The predictions from our models were always better than those predicted by the TotalSegmentator. The sDICE with 2 mm margin was larger than 80% for almost all the structures. Individual structures with decreased segmentation accuracy are analyzed and discussed with respect to their impact on the CTV delineation following the expert guidelines. No deviation is expected to affect the rule-based automation of the CTV delineation.
Collapse
Affiliation(s)
- Alexandra Walter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
- Karlsruhe Institute of Technology (KIT), Scientific Computing Center, Zirkel 2, 76131 Karlsruhe, Germany
| | - Philipp Hoegen-Saßmannshausen
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
- Department of Radiation Oncology, Heidelberg University Hospital, 69120 Heidelberg, Germany
- Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
- National Center for Tumor Diseases (NCT), NCT Heidelberg, 69120 Heidelberg, Germany
| | - Goran Stanic
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, 69120 Heidelberg, Germany
| | - Joao Pedro Rodrigues
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
| | - Sebastian Adeberg
- Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, 35043 Marburg, Germany
- Marburg Ion-Beam Therapy Center (MIT), 35043 Marburg, Germany
- Universitäres Centrum für Tumorerkrankungen (UCT), 35033 Marburg, Germany
| | - Oliver Jäkel
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
- Heidelberg Ion-Beam Therapy Center (HIT), 69120 Heidelberg, Germany
| | - Martin Frank
- Karlsruhe Institute of Technology (KIT), Scientific Computing Center, Zirkel 2, 76131 Karlsruhe, Germany
| | - Kristina Giske
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO), 69120 Heidelberg, Germany
| |
Collapse
|
2
|
Mardor I, Dickel T, Amanbayev D, Ayet San Andrés S, Beck S, Benyamin D, Bergmann J, Constantin P, Cléroux Cuillerier A, Geissel H, Gröff L, Hornung C, Kripko-Koncz G, Mollaebrahimi A, Miskun I, Plaß WR, Pomp S, Rotaru A, Scheidenberger C, Stanic G, Will C. Determining spontaneous fission properties by direct mass measurements with the FRS Ion Catcher. EPJ Web Conf 2020. [DOI: 10.1051/epjconf/202023902004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
We present a direct method to measure fission product yield distributions (FPY) and isomeric yield ratios (IYR) for spontaneous fission (SF) fragments. These physical properties are of utmost importance to the understanding of basic nuclear physics, the astrophysical rapid neutron capture process ('r process') of nucleosynthesis, neutron star composition, and nuclear reactor safety. With this method, fission fragments are produced by spontaneous fission from a source that is mounted in a cryogenic stopping cell (CSC), thermalized and stopped within it, and then extracted and transported to a multiple-reflection time-of-flight mass-spectrometer (MR-TOF-MS). We will implement the method at the FRS Ion Catcher (FRS-IC) at GSI (Germany), whose MR-TOF-MS relative mass accuracy (~ 10-7) and resolving power (~ 600,000 FWHM) are sufficient to separate all isobars and numerous isomers in the fission fragment realm. The system's essential element independence and its fast simultaneous mass measurement provide a new direct way to measure isotopic FPY distributions, which is complementary to existing methods. It will enable nuclide FPY measurements in the high fission peak, which is hardly accessible by current techniques. The extraction time of the CSC, tens of milliseconds, enables a direct measurement of independent fission yields, and a first study of the temporal dependence of FPY distributions in this duration range. The ability to resolve isomers will further enable direct extraction of numerous IYRs while performing the FPY measurements. The method has been recently demonstrated at the FRS-ICr for SF with a 37 kBq 252Cf fission source, where about 70 different fission fragments have been identified and counted. In the near future, it will be used for systematic studies of SF with a higher-activity 252Cf source and a 248Cm source. The method can be implemented also for neutron induced fission at appropriate facilities.
Collapse
|
3
|
Abstract
Although substantial evidence indicates that the progression of pathological changes of the neuronal cytoskeleton is crucial in determining the severity of dementia in Alzheimer's disease (AD), the exact causes and evolution of these changes, the initial site at which they begin, and the neuronal susceptibility levels for their development are poorly understood. The current clinical criteria for diagnosis of AD are focused mostly on cognitive deficits produced by dysfunction of hippocampal and high-order neocortical areas, whereas noncognitive, behavioural and psychological symptoms of dementia such as disturbances in mood, emotion, appetite, and wake-sleep cycle, confusion, agitation and depression have been less considered. The early occurrence of these symptoms suggests brainstem involvement, and more specifically of the serotonergic nuclei. In spite of the fact that the Braak and Braak staging system and National Institutes of Aging - Reagan Institute (NIA-RI) criteria do not include their evaluation, several recent reports drew attention to the possibility of selective and early involvement of raphe nuclei, particularly the dorsal raphe nucleus (DRN), in the pathogenesis of AD. Based on these findings of differential susceptibility and anatomical connectivity, a novel pathogenetic scheme of AD progression was proposed. Although the precise mechanisms of neurofibrillary degeneration still await elucidation, we speculated that cumulative oxidative damage may be the main cause of DRN alterations, as the age is the main risk factor for sporadic AD. Within such a framework, beta-amyloid production is considered only as one of the factors (although a significant one in familial cases) that promotes molecular series of events underlying AD-related neuropathological changes.
Collapse
Affiliation(s)
- G Simic
- Department of Neuroscience, Croatian Institute for Brain Research, Medical School Zagreb, Croatia.
| | | | | | | | | | | |
Collapse
|