1
|
Choi SY, Kim JH, Eun HW, Ryu H. Factors affecting the ability of abdominal ultrasonography to detect focal pancreatic lesions identified using endoscopic ultrasonography. Ultrasonography 2020; 39:247-256. [PMID: 32311871 PMCID: PMC7315294 DOI: 10.14366/usg.19078] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 02/09/2020] [Indexed: 12/18/2022] Open
Abstract
Purpose This study was conducted to determine which factors influence the ability of abdominal ultrasonography (US) to detect focal pancreatic lesions identified using endoscopic ultrasonography (EUS). Methods In this study, 338 consecutive patients with focal pancreatic lesions (cyst, n=253; adenocarcinoma, n=54; pancreatic neuroendocrine tumor, n=24; solid pseudopapillary neoplasm, n=4; intrapancreatic accessory spleen, n=1; metastasis, n=1; and lymphoma, n=1) detected by EUS who underwent US were enrolled. We reviewed their radiologic reports and assessed the presence or absence of a focal lesion, the multiplicity of the lesions, and their size and location on US. We evaluated how these parameters differed depending on whether the lesion was solid or cystic. Univariate and multivariate logistic regression analysis were performed. Results The overall detection rate of focal pancreatic lesions by US was 61.5% (208 of 338). Using US, the detection rate of cystic lesions was 58.5% (148 of 253), while that of solid lesions was 70.6% (60 of 85). In the univariate analysis, location in the neck or body, solid characteristics, and a relatively large size (15.50±10.08 mm vs. 23.09±12.93 mm) were associated with a significantly higher detection rate (P<0.001, P=0.047, and P<0.001, respectively). In the multivariate analysis, location in the neck or body (odds ratio [OR], 3.238; 95% confidence interval [CI], 1.926 to 5.443; P<0.001) and size (OR, 1.070; 95% CI, 1.044 to 1.096; P<0.001) were proven to be significant predictors of detectability (P<0.001). Conclusion US is useful for detecting focal pancreatic lesions, especially when they are located in the neck or body and are relatively large.
Collapse
Affiliation(s)
- Seo-Youn Choi
- Department of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon, Korea
| | - Jung Hoon Kim
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul, Korea
| | - Hyo Won Eun
- Department of Radiology, Samsung Medical Center, Seoul, Korea
| | - Hwaseong Ryu
- Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
2
|
Choi SY, Kim JH, Yu MH, Eun HW, Lee HK, Han JK. Diagnostic performance and imaging features for predicting the malignant potential of intraductal papillary mucinous neoplasm of the pancreas: a comparison of EUS, contrast-enhanced CT and MRI. Abdom Radiol (NY) 2017; 42:1449-1458. [PMID: 28144718 DOI: 10.1007/s00261-017-1053-3] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To compare diagnostic performance for prediction of malignant potential in IPMNs between EUS, contrast-enhanced CT and MRI. MATERIALS AND METHODS 76 patients with IPMN (benign = 37, malignant = 39) underwent EUS, contrast-enhanced CT, and MRI. EUS was analyzed based on formal reports and contrast-enhanced CT and MRI were retrospectively analyzed by two radiologists according to the consensus guidelines 2012. Diagnostic performance and imaging features of malignant IPMNs were analyzed using ROC analysis and multivariate analyses. RESULTS Diagnostic performance of contrast-enhanced CT (AUC = 0.792 in R1, 0.830 in R2), MRI (AUC = 0.742 in R1, 0.776 in R2), and EUS (AUC = 0.733) for predicting malignant IPMNs were comparable without significant difference (p > 0.05). In multivariable analysis, enhancing solid component in contrast-enhanced CT and MRI and mural nodule in EUS (OR 1.8 in CT, 1.36 in MRI, 1.47 in EUS), MPD diameter ≥ 10 mm (OR 1.3 in CT, 1.4 in MRI, 1.66 in EUS), MPD diameter of 5-9 mm (OR 1.23 in CT, 1.31 in MRI), and thickened septa or wall (OR 1.3 in CT and MRI) were significant variables (p < 0.05). Interobserver agreement of thickened cyst septa or wall (k = 0.579-0.617) and abrupt caliber change of MPD (k = 0.689-0.788) was lower than other variables (k > 0.80). CONCLUSION Diagnostic performance of contrast-enhanced CT, MRI, and EUS for predicting malignant IPMNs was comparable with each modalities without significant difference.
Collapse
Affiliation(s)
- Seo-Youn Choi
- Department of Radiology, Soonchunhyang University Bucheon Hospital, 170 Jomaru-ro, Wonmi-gu, Bucheon, 420-767, Republic of Korea
| | - Jung Hoon Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehang-no, Chongno-gu, Seoul, 110-744, Republic of Korea.
| | - Mi Hye Yu
- Department of Radiology, Konkuk University Hospital, Konkuk University School of Medicine, Seoul, Republic of Korea
| | - Hyo Won Eun
- Department of Radiology, Samsung Medical Center, 50 Ilwon-Dong, Kangnam-Ku, Seoul, 135-710, Republic of Korea
| | - Hae Kyung Lee
- Department of Radiology, Soonchunhyang University Bucheon Hospital, 170 Jomaru-ro, Wonmi-gu, Bucheon, 420-767, Republic of Korea
| | - Joon Koo Han
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehang-no, Chongno-gu, Seoul, 110-744, Republic of Korea
| |
Collapse
|
3
|
Kim JH, Eun HW, Kim YJ, Han JK, Choi BI. Staging accuracy of MR for pancreatic neuroendocrine tumor and imaging findings according to the tumor grade. ACTA ACUST UNITED AC 2014; 38:1106-14. [PMID: 23728305 DOI: 10.1007/s00261-013-0011-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE To investigate staging accuracy of MR for pancreatic neuroendocrine neoplasms (PNETs) and imaging findings according to the tumor grade. MATERIALS AND METHODS Our study consisted of 39 patients with PNET G1 (n = 24), PNET G2 (n = 12), and pancreatic neuroendocrine carcinoma (PNEC) (n = 3). All underwent preoperative MRI. Two radiologists retrospectively reviewed MR findings including tumor margin, SI on T2WI, enhancement patterns, degenerative change, duct dilation, and ADC value. They also assessed T-stage, N-stage, and tumor size. Statistical analyses were performed using Chi square tests, ROC analysis, and Fisher's exact test. RESULTS Specific findings for PNEC or PNET G2 were ill-defined borders (P = 0.001) and hypo-SI on venous- and delayed-phase (P = 0.016). ADC value showed significant difference between PNET G1 and G2 (P = 0.007). The Az of ADC value for differentiating PNET G1 from G2 was 0.743. Sensitivity and specificity were 70% and 86%. Accuracy for T-staging was 77% (n = 30) and 85% (n = 33), and for N-staging was 92% (n = 36) and 87% (n = 34) with moderate agreement. T-stage showed significant difference according to tumor grade (P < 0.001), although there was no significant difference in tumor size or N-stage. CONCLUSION Ill-defined borders and hypo-SI on venous- and delayed-phase imaging are common findings of higher grade PNET, and ADC value is helpful for differentiating PNET G1 from G2. MR is useful for preoperative evaluation of T-, N-stage. Tumor size of PNET and T-stage showed significant difference according to tumor grade.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehang-no, Chongno-gu, Seoul, 110-744, Republic of Korea,
| | | | | | | | | |
Collapse
|
4
|
Kim JH, Eun HW, Hong SS, Kim YJ, Han JK, Choi BI. Gastric cancer detection using MDCT compared with 2D axial CT: diagnostic accuracy of three different reconstruction techniques. ACTA ACUST UNITED AC 2013; 37:541-8. [PMID: 22080389 DOI: 10.1007/s00261-011-9823-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To assess the diagnostic accuracy of different reconstruction techniques using MDCT for gastric cancer detection compared with 2D axial CT. MATERIALS AND METHODS During 7 months, we performed CT examinations of 104 consecutive patients with gastric cancer and of a control group composed of 35 patients without gastric disease. All gastric cancer was pathologically proven by endoscopy and surgery. Among 104 patients with gastric cancer, 63 patients had early gastric cancer (EGC). Two radiologists retrospectively and independently interpreted the axial CT and three different reconstruction techniques including multiplanar reformation (MPR), transparent imaging (TI), and virtual gastroscopy (VG), using a commercially available, 3D workstation. They graded the presence or absence of gastric cancer in each image sets using a five-point scale and, if present, they assessed its location. Diagnostic accuracy was compared using the area under the receiver operating characteristic curve (Az) for both gastric cancer and only EGC. Sensitivity and specificity were also calculated for each image technique. The k statistics were used to determine inter-observer agreement. RESULTS The diagnostic accuracy for overall gastric cancer detection for each of the image sets was as follows: 2D axial CT (Az = 0.858); MPR (Az = 0.879); TI (Az = 0.873); and VG (Az = 0.928). VG had significantly better performance than 2D axial CT (p = 0.016). The sensitivity and specificity were as follows: 76.7% and 82.9% in axial CT; 79.6% and 85.7% in MPR; 91.3% and 80% in TI; and 95.1% and 74.3% in VG. In EGC, the diagnostic performance for its detection was as follows: axial CT (Az = 0.777); MPR (Az = 0.811); TI (Az = 0.825); and VG (Az = 0.896). VG had significantly better performance than both 2D axial CT (P = 0.006) and MRP (P = 0.038). The sensitivity and specificity were as follows: 62.9% and 82.9% in axial CT; 67.7% and 85.7% in MPR; 85.5% and 80% in TI; and 91.9% and 74.3% in VG. The inter-observer agreement showed substantial agreement (κ = 0.67-0.75). CONCLUSION Among the different reconstruction techniques, VG accurately detects gastric cancer and is especially useful for EGC compared with 2D axial CT.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, Seoul National University College of Medicine, Chongno-gu, Korea.
| | | | | | | | | | | |
Collapse
|
5
|
Eun HW, Kim JH, Hong SS, Kim YJ. Malignant versus benign hepatic masses in patients with recurrent pyogenic cholangitis: MR differential diagnosis. Abdom Radiol (NY) 2012; 37:767-74. [PMID: 22179742 DOI: 10.1007/s00261-011-9833-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess MR findings and diagnostic performance for differentiating malignant from benign hepatic masses in recurrent pyogenic cholangitis (RPC). MATERIALS AND METHODS During a recent 6-year period, we performed MRI in 352 patients with RPC. Among them, 58 had confirmed hepatic masses; cholangiocarcinoma (n = 15), abscess (n = 37), inflammatory pseudotumor (n = 3), biloma (n = 3). Two radiologists assessed MR findings including enhancement patterns, intratumoral appearance, peritumoral changes, mass location, and multiplicity. They also graded the malignancy using common MR findings. The receiver operating characteristic analysis and Chi-square test were used. The κ statistics was used to determine interobserver agreement. RESULTS The common findings for cholangiocarcinoma were thin and lobulated enhancement at the periphery (n = 8, 53%, P < 0.05); ill-defined enhancement (n = 7, 47%, P < 0.05); slightly high signal on T2 (n = 13, 87%, P < 0.05); mass located in the same lobe of atrophy (n = 11, 73%, P < 0.05) and portal vein thrombosis (n = 15, 100%, P < 0.05). The common findings for benign mass were target-like enhancement (n = 36, 84%, P < 0.05); cluster appearance (n = 15, 35%, P < 0.05); central, fluid-like space (n = 29, 67%, P < 0.05); peritumoral regional high signal on T2 (n = 32, 74%, P < 0.05); multiplicity(n = 21, 49%, P < 0.05). Interobserver agreement was excellent (κ = 0.81-1.000). Area under the curve (Az) for differentiating malignant masses was 0.989, sensitivity was 95.3%, and specificity was 95.3%. There was good interobserver agreement (κ = 0.74). CONCLUSION MR imaging is very useful for differential diagnosis of malignant vs. benign hepatic masses in patients with RPC.
Collapse
Affiliation(s)
- Hyo Won Eun
- Health Promotion Center, Asan Medical Center, University of Ulsan, 388-1 Poongnap-dong, Songpa-gu, Seoul, 138-736, Korea.
| | | | | | | |
Collapse
|
6
|
Eun HW, Kim JH, Hong SS, Kim YJ. Assessment of acute cholangitis by MR imaging. Eur J Radiol 2012; 81:2476-80. [DOI: 10.1016/j.ejrad.2011.10.020] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 10/18/2011] [Accepted: 10/19/2011] [Indexed: 12/07/2022]
|
7
|
Kim JH, Eun HW, Park HJ, Hong SS, Kim YJ. Diagnostic performance of MRI and EUS in the differentiation of benign from malignant pancreatic cyst and cyst communication with the main duct. Eur J Radiol 2012; 81:2927-35. [PMID: 22227264 DOI: 10.1016/j.ejrad.2011.12.019] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2011] [Revised: 12/03/2011] [Accepted: 12/05/2011] [Indexed: 12/13/2022]
Abstract
PURPOSE To assess the diagnostic ability of MRI and EUS for differentiating benign from malignant pancreatic cyst focusing on cyst communication with pancreatic duct. MATERIALS AND METHODS During 44 months, we performed MRI on 65 pancreatic cysts. Among them, 36 patients had confirmed cyst communication with duct by ERCP or surgery and 39 patients underwent EUS. Fifty-one had proven by surgery or aspiration. Among them, 36 had confirmed malignant cysts. Two radiologists independently graded cyst communication with duct and the likelihood of malignancy. When the readers' interpretations differed, third opinion was obtained. They also measured the size of cyst and main duct. The diagnostic performance was analyzed using the ROC curve. The Mann-Whitney U test and κ statistics were used to determine interobserver agreement. RESULTS The Az of MRI and EUS for determining diagnostic performance regarding the cyst communication with duct, were 0.931 and 0.930, without statistically difference (p=0.6). Interobserver agreement was excellent (κ=0.81) on MRI and substantial (κ=0.69) on EUS. The Az of MRI and EUS for assessing diagnostic performance to differentiate malignant from benign cyst, was 0.902 and 0.923, without statistically difference (p=0.587). Interobserver agreement was excellent (κ=0.81) on MRI and moderate (κ=0.47) on EUS. The mean cyst size (3.98 cm+2.74: 3.17 cm+1.26, p=0.327) and the duct size (5.20 mm+3.22: 4.39 mm+4.12, p=0.227) showed no statistically difference between malignant and benign cysts. CONCLUSION MRI and EUS can accurately assess pancreatic cyst communication with duct and are very useful for obtaining a differential diagnosis of malignant cyst versus benign pancreatic cyst.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, and Soonchunhyang University Hospital, 101 Daehang-no, Chongno-gu, Seoul 110-744, Republic of Korea.
| | | | | | | | | |
Collapse
|
8
|
Kim JH, Hong SS, Eun HW, Han JK, Choi BI. Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: comparison with conventional breath-hold 2D MRCP. Eur J Radiol 2011; 81:e513-8. [PMID: 21700409 DOI: 10.1016/j.ejrad.2011.06.004] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2011] [Accepted: 06/01/2011] [Indexed: 01/10/2023]
Abstract
PURPOSE To assess the clinical usefulness of free-breathing 3D MRCP in non-cooperative patients compared conventional breath-hold 2D MRCP. MATERIALS AND METHODS We performed FB navigator-triggered 3D MRCP using prospective acquisition correction and BH 2D MRCP in 48 consecutive, non-cooperative patients among 772 patients. Thirteen patients had malignant obstruction. Two radiologists independently graded the likelihood of a malignant obstruction, the overall image quality, and the visibility of ten, individual anatomic segments of both the biliary and pancreatic duct in each sequence. The area under the ROC curve and the repeated measures analyses of variance with multiple comparisons were used for the comparison. The κ statistics were used for interobserver agreement. RESULT The diagnostic performance for detecting malignancy was significantly higher on FB MRCP (A(z)=0.962) than on either BH SS-RARE (A(z)=0.820, P<0.0185) or MS-HASTE MRCP (A(z)=0.816, P<0.0067). Interobserver agreement was excellent for FB MRCP (κ=0.889) and fair for both BH SS-RARE (κ=0.578) and MS-HASTE MRCP (κ=0.49). FB MRCP had a significantly higher technical quality than BH MRCP (P<0.001). FB MRCP was seen to have statistically better visibility of peripheral IHD, right main IHD, CHD, cystic duct, and CBD than BH MRCP (P<0.001). FB MRCP and BH SS-RARE MRCP had statistically better visibility of both the left main IHD and pancreatic duct than did BH MS-HASTE MRCP (P<0.001). CONCLUSION FB 3D MRCP is useful for non-cooperative patients in whom conventional BH 2D methods cannot be used successfully.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehang-no, Chongno-gu, Seoul 110-744, Republic of Korea.
| | | | | | | | | |
Collapse
|
9
|
Kim JH, Hong SS, Kim YJ, Kim JK, Eun HW. Intraductal papillary mucinous neoplasm of the pancreas: differentiate from chronic pancreatits by MR imaging. Eur J Radiol 2011; 81:671-6. [PMID: 21324627 DOI: 10.1016/j.ejrad.2011.01.066] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2010] [Revised: 01/13/2011] [Accepted: 01/17/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE To evaluate the differentiating factors for intraductal papillary mucinous neoplasm of the pancreas and chronic pancreatitis as determined by MR imaging. MATERIALS AND METHODS During a three-year period, we performed MR imaging on 33, consecutive patients with IPMN and on 41 patients with chronic pancreatitis. All IPMNs were confirmed by surgery. Two radiologists retrospectively analyzed the ductal change, the cyst shape, CBD dilatation, lymphadenopathy, and parenchymal change. The sensitivity and specificity were calculated for each MRI findings using the Chi square test. Statistically significant MR findings were further analyzed using multivariate logistic regression analysis. The diagnostic performance was evaluated according to the area under the receiver operating characteristic curve (A(z)) using specific MRI findings. Simple κ statistics were used to evaluate the inter-observer reliability. RESULTS Statistically specific findings for IPMN compared with those for chronic pancreatitis, were duct dilatation without stricture (specificity=95.1%, sensitivity=75.8%, p<0.0001), bulging ampulla (specificity=97.6%, sensitivity=30.3%, p<0.0001), nodule in a duct (specificity=100%, sensitivity=15.2%, p<0.0004), grape-like cyst shape (specificity=97.6%, sensitivity=78.8%, p<0.0001), and nodule in a cyst (specificity=100%, sensitivity=24.2%, p<0.0001). Statistically specific findings for chronic pancreatitis compared with those for IPMN, were duct dilatation with strictures (specificity=93.9%, sensitivity=95.1%, p<0.0001), the presence of a stone (specificity=97.0%, sensitivity=56.1%, p<0.0001), and a unilocular cyst shape (specificity=93.9%, sensitivity=34.1%, p<0.0004). Duct dilatation without stricture and a grape-like cyst shape were independently associated with the IPMN. Duct dilatation with strictures was independently associated with the chronic pancreatitis. Interobserver agreement was good to excellent for each finding (κ=0.762-1.000). CONCLUSION Highly specific findings for IPMN include duct dilatation without stricture, bulging ampulla, nodule in a duct, grape-like cyst shape, and nodule in a cyst. MRI is very useful for differentiating IPMN from chronic pancreatitis using these specific findings.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehang-no, Chongno-gu, Seoul 110-744, Republic of Korea.
| | | | | | | | | |
Collapse
|
10
|
Kim SH, Lee JM, Park HS, Eun HW, Han JK, Choi BI. Accuracy of MRI for predicting the circumferential resection margin, mesorectal fascia invasion, and tumor response to neoadjuvant chemoradiotherapy for locally advanced rectal cancer. J Magn Reson Imaging 2009; 29:1093-101. [PMID: 19388124 DOI: 10.1002/jmri.21742] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To evaluate the diagnostic accuracy of MRI for predicting the circumferential resection margin (CRM), mesorectal fascia (MRF) invasion, and the tumor response to neoadjuvant chemoradiotherapy (CRT) for locally advanced rectal cancer. MATERIALS AND METHODS Sixty-five consecutive patients with locally advanced rectal cancer (> or =T3 or lymph node-positive) who underwent neoadjuvant CRT and subsequent surgery were enrolled in this retrospective study. Two blinded radiologists independently reviewed both the pre- and post-CRT rectal MR images and measured the post-CRT CRM; they recorded their confidence level with respect to the MRF invasion and tumor response using a 5-point scale. The diagnostic accuracy of each reviewer was calculated using receiver operating characteristic curve (ROC) analysis. RESULTS The measured CRM was not significantly different from the reference standard (mean difference, -1.4 mm; 95% limits of agreement, -8.3-5.4 mm; interclass correlation coefficient, 0.82). The diagnostic accuracy (A(z)) for determining MRF invasion was 0.890 for reviewer 1 (95% confidence interval [CI], 0.788-0.954) and 0.829 for reviewer 2 (95% CI, 0.715-0.911). The A(z) for predicting complete or near-complete regression was 0.791 for reviewer 1 (95% CI, 0.672-0.882) and 0.735 for reviewer 2 (95% CI, 0.611-0.837). CONCLUSION MRI provides accurate information regarding the CRM of locally advanced rectal cancer after neoadjuvant CRT; it also shows relatively high accuracy for predicting MRF invasion and moderate accuracy for assessing tumor response.
Collapse
Affiliation(s)
- Seung Ho Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
11
|
Affiliation(s)
- Joon Koo Han
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
| | | | | |
Collapse
|
12
|
Affiliation(s)
- Joon Koo Han
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.
| | | | | |
Collapse
|
13
|
Kim SH, Lee JM, Shin CI, Kim HC, Lee JG, Kim JH, Choi JY, Eun HW, Han JK, Lee JY, Choi BI. Effects of Spatial Resolution and Tube Current on Computer-aided Detection of Polyps on CT Colonographic Images: Phantom Study. Radiology 2008; 248:492-503. [DOI: 10.1148/radiol.2482071025] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
14
|
Kim SH, Choi BI, Lee JY, Kim SJ, So YH, Eun HW, Lee JM, Han JK. Diagnostic accuracy of multi-/single-detector row CT and contrast-enhanced MRI in the detection of hepatocellular carcinomas meeting the milan criteria before liver transplantation. Intervirology 2008; 51 Suppl 1:52-60. [PMID: 18544949 DOI: 10.1159/000122598] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Liver transplantation has been considered to be the only causal treatment for liver cirrhosis patients with hepatocellular carcinoma (HCC) due to its theoretical advantage of eliminating both the tumor and liver disease. However, because of the shortage of donor organs, it is strongly recommended that liver transplantations should be performed on cirrhotic patients with HCCs only when the patients meet the predetermined criteria in terms of number and extent of HCCs. Imaging is thus decisive in the patient inclusion or exclusion from transplantation lists. The imaging techniques used are CT, MRI and ultrasonography. The latter has been proven to be ineffective for HCC surveillance in transplant recipients because of its heavy operator dependence and unreliable detection of small and intermediately sized HCCs. The purpose of this article, then, is to systematically review the diagnostic performances of single-/multidetector row CT, dynamic gadolinium-enhanced MRI, superparamagnetic iron oxide (SPIO)-enhanced MRI and double-contrast MRI using both gadolinium and SPIO for the detection of HCCs with special emphasis on liver transplantation.
Collapse
Affiliation(s)
- Se Hyung Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University Hospital, Seoul, Republic of Korea
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Kim JH, Eun HW, Choi JH, Hong SS, Kang W, Auh YH. Diagnostic performance of virtual gastroscopy using MDCT in early gastric cancer compared with 2D axial CT: focusing on interobserver variation. AJR Am J Roentgenol 2007; 189:299-305. [PMID: 17646454 DOI: 10.2214/ajr.07.2201] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE The objective of our study was to assess the diagnostic performance of virtual gastroscopy using MDCT for the detection of early gastric cancer (EGC) compared with 2D axial CT, focusing on interobserver reliability. MATERIALS AND METHODS During an 11-month period, we performed CT examinations of 94 consecutive patients with EGC and a control group composed of 68 patients without EGC. Three radiologists retrospectively interpreted the 2D axial CT and virtual gastroscopy images. Diagnostic performances were compared within each observer using the area under the receiver operating characteristic curve (A(z)). Sensitivity and specificity were also calculated for each individual observer. The simple kappa statistic was used to evaluate interobserver reliability in the detection of EGC. RESULTS The diagnostic performance for overall lesion detection in patients with EGC was significantly higher with virtual gastroscopy (A(z) = 0.829-0.885) than with 2D axial CT (A(z) = 0.734-0.793) (p < 0.001). The sensitivity and specificity of virtual gastroscopy for EGC were 78.7-84.0% and 83.8-91.2%, respectively. The sensitivity and specificity of 2D axial CT for EGC were 62.8-69.2% and 83.8-92.7%, respectively. Virtual gastroscopy showed a higher sensitivity for EGC than 2D axial CT (p < 0.001). The interobserver reliabilities showed moderate to substantial agreement (kappa = 0.40-0.74 for 2D axial CT, kappa = 0.57-0.71 for virtual gastroscopy). CONCLUSION Virtual gastroscopy showed excellent results with a good interobserver reliability for the detection of EGC compared with 2D axial CT.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, Soonchunhyang University Hospital, 657 Hannam-Dong, Youngsan-Ku, Seoul 140-743, Korea.
| | | | | | | | | | | |
Collapse
|
16
|
Kim SH, Lee JM, Eun HW, Lee MW, Han JK, Lee JY, Choi BI. Two- versus Three-dimensional Colon Evaluation with Recently Developed Virtual Dissection Software for CT Colonography. Radiology 2007; 244:852-64. [PMID: 17709833 DOI: 10.1148/radiol.2443060934] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This retrospective study was institutional review board approved; the requirement for informed patient consent was waived. The purpose of this study was to retrospectively compare a two-dimensional (2D) data interpretation technique with a three-dimensional (3D) colon dissection technique in terms of interpretation time and sensitivity for colonic polyp detection, with colonoscopy as the reference standard. Ninety-six patients (56 men, 40 women; mean age, 54.8 years) underwent colonoscopy and multidetector computed tomographic (CT) colonography on the same day. Two radiologists independently analyzed the data on a per-polyp and per-patient basis. The sensitivity of both approaches was compared by using the McNemar test. The time required to interpret CT colonographic data with each technique was also assessed. Compared with the conventional 2D colonic polyp detection method, primary 3D interpretation with use of virtual dissection software for CT colonography revealed comparable per-polyp (77% and 69% for two readers) and per-patient (77% and 73% for two readers) sensitivities and comparable per-patient specificity (99% and 89% for two readers) for the detection of polyps 6 mm in diameter or larger and involved a shorter interpretation time.
Collapse
Affiliation(s)
- Se Hyung Kim
- Department of Radiology and Institute of Radiation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 28 Yongon-dong, Chongno-gu, Seoul 110-744, Korea
| | | | | | | | | | | | | |
Collapse
|
17
|
Kim JH, Kim TK, Eun HW, Byun JY, Lee MG, Ha HK, Auh YH. CT Findings of Cholangiocarcinoma Associated with Recurrent Pyogenic Cholangitis. AJR Am J Roentgenol 2006; 187:1571-7. [PMID: 17114552 DOI: 10.2214/ajr.05.0486] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of our study was to determine the characteristic CT findings of cholangiocarcinoma associated with recurrent pyogenic cholangitis. CONCLUSION CT findings of cholangiocarcinoma associated with recurrent pyogenic cholangitis are important in order to improve early diagnosis and proper treatment. Cholangiocarcinoma associated with recurrent pyogenic cholangitis is predominantly located in the atrophic hepatic lobes and in the hepatic lobes of biliary calculi and is associated with the narrowing or obliteration of the portal vein.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, Soonchunhyang University Hospital, 657 Hannam-Dong, Youngsan-Ku, Seoul, South Korea 140-743.
| | | | | | | | | | | | | |
Collapse
|
18
|
Kim JH, Eun HW, Goo DE, Shim CS, Auh YH. Imaging of various gastric lesions with 2D MPR and CT gastrography performed with multidetector CT. Radiographics 2006; 26:1101-16; discussion 1117-8. [PMID: 16844934 DOI: 10.1148/rg.264055089] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Recent advances in computed tomographic (CT) technology, three-dimensional imaging software, and cheaper data storage capacity have made faster, simpler, and more accurate gastric imaging available. Two-dimensional multiplanar reformation and CT gastrography including virtual gastroscopy and transparency rendering allow multiplanar cross-sectional imaging, gastroscopic viewing, and upper gastrointestinal series imaging in the same data acquisition. Multi-detector row CT allows noninvasive assessment of the gastric wall and the perigastric extent of disease. It is also helpful in detection and evaluation of gastric malignancies and a variety of inflammatory conditions that affect the stomach. Conventional gastroscopy provides the most useful information about the exact location of the lesion and also allows performance of biopsy. Endoscopic ultrasonography (US) provides the most useful information about horizontal extension of the tumor, the depth of mural invasion, and perigastric lymphadenopathy. However, endoscopic US has not been able to replace CT for tumor staging because of its limitations in demonstrating distant lymphadenopathy or metastatic deposits.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, Soonchunhyang University Hospital, 657 Hannam-Dong, Youngsan-Ku, Seoul 140-743, Korea.
| | | | | | | | | |
Collapse
|
19
|
Chung KW, Kim SB, Park KD, Choi KG, Lee JH, Eun HW, Suh JS, Hwang JH, Kim WK, Seo BC, Kim SH, Son IH, Kim SM, Sunwoo IN, Choi BO. Early onset severe and late-onset mild Charcot-Marie-Tooth disease with mitofusin 2 (MFN2) mutations. Brain 2006; 129:2103-18. [PMID: 16835246 DOI: 10.1093/brain/awl174] [Citation(s) in RCA: 192] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Mutations in the mitofusin 2 (MFN2) gene, which encodes a mitochondrial GTPase mitofusin protein, have recently been reported to cause both Charcot-Marie-Tooth 2A (CMT2A) and hereditary motor and sensory neuropathy VI (HMSN VI). It is well known that HMSN VI is an axonal CMT neuropathy with optic atrophy. However, the differences between CMT2A and HMSN VI with MFN2 mutations remained to be clarified. Therefore, we studied the phenotypic characteristics of CMT patients with MFN2 mutations. Mutations in MFN2 were screened in 62 unrelated axonal CMT neuropathy families. We calculated CMT neuropathy scores (CMTNSs) and functional disability scales (FDSs) to quantify disease severity. Twenty-one patients with the MFN2 mutations were studied by brain MRI. Ten pathogenic mutations were identified in 26 patients from 15 families (24.2%). Six of these mutations had not been reported, and de novo mutations were observed in five families (33.3%). The electrophysiological patterns of affected individuals with the MFN2 mutations were typical of axonal CMT; however, the clinical and electrophysiological characteristics were markedly different in early (<10 years) and late disease-onset (> or =10 years) groups. All patients with an early onset had severe CMTNS (> or =21) and FDS (6 or 7), whereas most patients with late onset had mild CMTNS (< or =10) and FDS (< or =3). We identified two HMSN VI families with the R364W mutation in the early onset group; however, two other families with the same mutation did not have optic atrophy. In addition, two early onset families with R94W mutations, previously reported for HMSN VI, did not have visual impairment. Interestingly, eight patients had periventricular and subcortical hyperintense lesions by brain MRI. In the late-onset group, three patients had sensorineural hearing loss and two had bilateral extensor plantar responses. We found that MFN2 mutations are the major cause of axonal CMT neuropathy, and that they are associated with variable CNS involvements. Phenotypes were significantly different in the early and late disease-onset groups. Our findings suggest that HMSN VI might be a variant of the early onset severe CMT2A phenotype.
Collapse
Affiliation(s)
- K W Chung
- Department of Neurology and Ewha Medical Research Center, Ewha Woman's University, College of Medicine, Dongdaemun Hospital, 70 Jongno 6-ga, Jongno-gu, 110-783, Seoul, Korea E-mail:
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Kim SH, Choi BI, Han JK, Lee JM, Eun HW, Lee JY, Lee KH, Han CJ, Choi YH, Shin KS. CT colonography in a Korean population with a high residue diet: Comparison between wet and dry preparations. Clin Radiol 2006; 61:483-94. [PMID: 16713419 DOI: 10.1016/j.crad.2006.01.012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2005] [Revised: 01/03/2006] [Accepted: 01/05/2006] [Indexed: 11/22/2022]
Abstract
AIM To compare wet and dry preparation methods for computed tomography colonography (CTC) in terms of preparation quality, interpretation time, and diagnostic performance for polyp detection in a population with a high residue diet. MATERIALS AND METHODS Eighty-six patients were divided into two groups. Group 1 (n=24) received a wet preparation of 4l polyethylene glycol (PEG) solution, and group 2 (n=62) received a dry preparation of phosphor-soda. Abnormal findings, including polyps, and the time required to interpret the CTC images in both groups were documented by a radiologist. CTC findings were compared to those of colonoscopy as a reference standard. Two radiologists evaluated the quality of CTC with regard to residual fluid, faeces, and colonic distension using a four-point scale in consensus. Statistical differences for residual fluid, faeces, distensibility on CTC, and interpretation time between the two groups were analysed. The diagnostic performance of CTC in both groups was also compared. RESULTS One-hundred and ninety polyps in 70 patients were identified using colonoscopy. Regarding the quality of images produced the wet preparation was significantly better than the dry preparation (p<0.05). The average interpretation time was significantly shorter for the wet group (11.7 min) than the dry group (16.4 min) (p<0.05). For per-patient analysis, the positive predictive value (PPV) was significantly better for the wet (100%) than the dry group (79.6%; p=0.025). Sensitivities and PPV for >or=10 mm polyps were comparable between two groups (p>0.05). CONCLUSION In a population with a high-residue diet, CTC with wet preparation can be interpreted in a time-efficient manner and is comparable with CTC with dry preparation.
Collapse
Affiliation(s)
- S H Kim
- Department of Radiology, Seoul National University Hospital, Seoul, South Korea
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Yi A, Kim JK, Park SH, Kim KW, Kim HS, Kim JH, Eun HW, Cho KS. Contrast-Enhanced Sonography for Prostate Cancer Detection in Patients with Indeterminate Clinical Findings. AJR Am J Roentgenol 2006; 186:1431-5. [PMID: 16632741 DOI: 10.2214/ajr.04.1959] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of our study was to evaluate the usefulness of contrast-enhanced sonography for prostate cancer detection in patients with an indeterminate prostate-specific antigen (PSA) level (4-10 ng/mL) and negative findings on digital rectal examination. SUBJECTS AND METHODS Forty-eight patients underwent gray-scale, color Doppler, and contrast-enhanced sonography examinations and then sonographically guided biopsy. Contrast-enhanced sonography was performed using Levovist at a mechanical index of 1.1-1.4. The performances of the three methods for cancer detection were compared according to biopsy site and patient. RESULTS Sensitivity by biopsy site was greater on contrast-enhanced sonography (68%) than on gray-scale (39%) and color Doppler (41%) sonography (p > or = 0.05), whereas the specificity and overall accuracy by biopsy site (82% and 77% for gray-scale sonography, 84% and 79% for color Doppler sonography, and 83% and 81% for contrast-enhanced sonography, respectively) were not different for the three methods (p > 0.05). The concordance score for sonography and biopsy results by patient was not different for gray-scale (6.4 +/- 1.8), color Doppler (6.3 +/- 0.6), and contrast-enhanced sonography (6.5 +/- 0.7) (p = 0.281). CONCLUSION Contrast-enhanced sonography could improve only the sensitivity for cancer detection in analysis by biopsy site but did not improve the overall performance of sonography in patients with an indeterminate PSA level and negative digital rectal examination.
Collapse
Affiliation(s)
- Ahn Yi
- Department of Radiology, Asan Medical Center, University of Ulsan, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, Korea
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Abstract
Gastric cancer is one of the most common cancers and one of the most frequent causes of cancer-related deaths worldwide. Early detection and accurate preoperative staging of early gastric cancer (ECG) offers the best prognosis and is essential for planning optimal therapy such as endoscopic mucosal resection or gastric resection. Recent advances in computed tomographic technology and three-dimensional imaging software have enabled more accurate gastric imaging. Virtual gastroscopy (VG) is helpful in the detection and evaluation of EGC in the same way as gastroscopy. VG has a wider field of view than conventional gastroscopy, the angle of the virtual cancer can be adjusted omnidirectionally, and it has no blind point because retrospective reconstruction is available. Thus, VG is a promising method for evaluating gastric lesions despite its limitations. This report describes the clinical usefulness of VG with multidetector row computed tomography for EGC and axial computed tomography.
Collapse
Affiliation(s)
- J H Kim
- Department of Radiology, Soon Chun Hyang University Hospital, 657, Hannam-Dong, Yongsan-Ku, Seoul 140-743, Korea.
| | | | | | | |
Collapse
|
23
|
Kim JH, Eun HW, Lee HJ, Goo DE, Choi DL. Clinical use of renal perfusion imaging by means of harmonic sonography with a microbubble contrast agent in patients after renal transplantation: preliminary study. J Ultrasound Med 2005; 24:755-62. [PMID: 15914679 DOI: 10.7863/jum.2005.24.6.755] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
OBJECTIVE The purpose of this research was to determine the feasibility of renal perfusion imaging by means of harmonic sonography with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation compared with technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) scans. METHODS During a 10-month period, 100 patients with renal transplantation that included normal perfusion (n=68) and delayed perfusion including chronic rejection (n=19), acute rejection (n=9), arterial stenosis (n=2), and urinary stricture (n=2) underwent sonographic renal perfusion imaging and (99m)Tc-DTPA scans. Sonographic images were obtained every 3 seconds for a total of 3 minutes after administration of a bolus injection of 4 g of the microbubble contrast agent at a concentration of 300 mg/mL. Sonographic renal perfusion images were converted into a renal perfusion curve, and the calculated time at the peak of the curve (T(peak)) was compared with that of the (99m)Tc-DTPA scan. RESULTS The T(peak) with the (99m)Tc-DTPA scan was 14.9 seconds in the normal group and 33 seconds in the delayed perfusion group. The T(peak) on sonographic renal perfusion images was 25 seconds in the normal group and 44.8 seconds in the delayed perfusion group. Sonographic renal perfusion images showed good correlation with the (99m)Tc-DTPA scan (r=0.74; P=.0001). The cutoff value of the T(peak) on sonographic renal perfusion images was 35 seconds (sensitivity=85%; specificity=90%). CONCLUSIONS The renal perfusion images obtained by means of harmonic sonography with a microbubble contrast agent constitute an effective sonographic technique for the evaluation of renal perfusion abnormalities after renal transplantation compared with a (99m)Tc-DTPA scan.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, Soonchunhyang University Hospital, 657 Hannam-Dong, Youngsan-Ku, Seoul 140-743, Korea.
| | | | | | | | | |
Collapse
|
24
|
Kim JH, Ha HK, Kim JK, Eun HW, Park KB, Kim BS, Kim TK, Kim JC, Auh YH. Usefulness of known computed tomography and clinical criteria for diagnosing strangulation in small-bowel obstruction: analysis of true and false interpretation groups in computed tomography. World J Surg 2003; 28:63-8. [PMID: 14648046 DOI: 10.1007/s00268-003-6899-6] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Computed tomography (CT) criteria have proven useful, but not sufficient, for diagnosis of bowel strangulation. The purpose of the present study was to evaluate the use of clinical criteria in the interpretation of CT scans as a means of improving the diagnostic accuracy of CT, especially in patients whose CT scans are equivocal for distinguishing simple obstruction from strangulated obstruction. We analyzed the CT scans of 136 patients with simple (n=70) or strangulated (n=66) small-bowel obstruction. Three radiologists interpreted the CT scans independently for the presence of intestinal strangulation. According to their interpretation, 136 patients were divided into two groups, i.e., a false and a true interpretation group. The diagnostic value of known CT and four clinical criteria (tenderness, tachycardia, fever, and leukocytosis) were compared in the two groups. The diagnostic accuracy of CT criteria for distinguishing simple obstructions from strangulated small-bowel obstructions ranged between 73% and 80%. Of the 136 patients, 31 belonged to the false group and 105 to the true group. The CT criteria that were highly specific in both groups included severe mesenteric haziness, serrated beak, and poor bowel wall enhancement. Among the clinical criteria, both tachycardia and leukocytosis were highly specific in both groups. The number of positive clinical criteria was helpful in making a diagnosis; none or one clinical criterion indicated a simple obstruction, whereas three or four criteria indicated a strangulated obstruction; when this result was applied retrospectively to the false group, the CT diagnostic accuracy improved in 19 of the 31 patients. The use of clinical criteria when CT findings are equivocal, may overcome the inherent limitations of CT for diagnosing strangulated small-bowel obstruction.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Poongnap-Dong, Songpa-Ku, 138-040 Seoul, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Abstract
PURPOSE Coded harmonic angio (CHA) US is a recently developed technique that can depict the effects of contrast agents. The purpose of this study was to determine the role of this technique in depicting the enhancement patterns of various renal perfusion abnormalities compared with dynamic CT. MATERIAL AND METHODS During a 6-month period, various renal lesions including renal cell carcinoma (n=12), transitional cell carcinoma (n=5), acute pyelonephritis (n=5), and renal trauma (n=2) were evaluated with CHA US using a microbubble contrast agent. US images were obtained before contrast administration and with a bolus injection of 4 g of microbubble contrast agent (300 mg/ml) every 10 s for 1 min and every minute for 5 min. The contrast enhancement patterns of various renal masses were compared with dynamic CT. RESULTS Of 12 renal cell carcinomas, 9 (75%) showed heterogeneous enhancement and the remaining 3 (25%) showed homogeneous enhancement. Enhancement of more than adjacent renal parenchyma was seen 16-252 s after injection. The duration of enhancement was 13-208 s (mean, 80 s). All transitional cell carcinomas showed peripheral enhancement. Enhancement was seen 22-270 s after injection. The duration of enhancement was 191-238 s (mean, 291 s). Five patients with acute pyelonephritis and 2 with renal trauma showed focal perfusion defects not shown on the pre-contrast examinations. CONCLUSION CHA US with microbubble contrast agent is an effective US technique for the evaluation of both tumor vascularity and renal perfusion abnormality.
Collapse
Affiliation(s)
- J H Kim
- Department of Radiology, Soonchunhyang University Hospital, Seoul, Korea.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Abstract
PURPOSE Coded harmonic angio (CHA) US is a recently developed technique that can depict the effects of contrast agents. The purpose of this study was to determine the role of this technique in depicting the enhancement patterns of various renal perfusion abnormalities compared with dynamic CT. MATERIAL AND METHODS During a 6-month period, various renal lesions including renal cell carcinoma (n=12), transitional cell carcinoma (n=5), acute pyelonephritis (n=5), and renal trauma (n=2) were evaluated with CHA US using a microbubble contrast agent. US images were obtained before contrast administration and with a bolus injection of 4 g of microbubble contrast agent (300 mg/ml) every 10 s for 1 min and every minute for 5 min. The contrast enhancement patterns of various renal masses were compared with dynamic CT. RESULTS Of 12 renal cell carcinomas, 9 (75%) showed heterogeneous enhancement and the remaining 3 (25%) showed homogeneous enhancement. Enhancement of more than adjacent renal parenchyma was seen 16-252 s after injection. The duration of enhancement was 13-208 s (mean, 80 s). All transitional cell carcinomas showed peripheral enhancement. Enhancement was seen 22-270 s after injection. The duration of enhancement was 191-238 s (mean, 291 s). Five patients with acute pyelonephritis and 2 with renal trauma showed focal perfusion defects not shown on the pre-contrast examinations. CONCLUSION CHA US with microbubble contrast agent is an effective US technique for the evaluation of both tumor vascularity and renal perfusion abnormality.
Collapse
Affiliation(s)
- J H Kim
- Department of Radiology, Soonchunhyang University Hospital, Seoul, Korea.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Kim JH, Kim TK, Eun HW, Kim BS, Lee MG, Kim PN, Ha HK. Preoperative evaluation of gallbladder carcinoma: efficacy of combined use of MR imaging, MR cholangiography, and contrast-enhanced dual-phase three-dimensional MR angiography. J Magn Reson Imaging 2002; 16:676-84. [PMID: 12451581 DOI: 10.1002/jmri.10212] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To determine the efficacy of the combined use of magnetic resonance (MR) imaging, MR cholangiography (MRC), and MR angiography (MRA) in the preoperative evaluation of gallbladder carcinoma. MATERIALS AND METHODS During a 20-month period, 41 patients with proven gallbladder carcinomas were referred for MR examination, including MR imaging, MRC, and gadolinium-enhanced dual-phase MRA to determine the operability of their gallbladder carcinoma. Eighteen patients who underwent surgery within six days of the MR examination were included in this study. All MR images were analyzed in order to assess bile duct invasion, vascular invasion, hepatic invasion or metastasis, lymph node metastasis, and invasion into adjacent organs. RESULTS Surgical and histopathologic findings revealed hepatic invasion in nine patients, bile duct invasion in nine, vascular invasion in three, and lymph node metastasis in 10. The sensitivity and specificity of MR examination were, respectively, 100% and 89% for bile duct invasion, 100% and 87% for vascular invasion, 67% and 89% for hepatic invasion, and 56% and 89% for lymph node metastasis. CONCLUSION The "all-in-one" MR protocol, including MR imaging, MRC, and MRA, can be an effective diagnostic method in the preoperative work-up for gallbladder carcinoma.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Diagnostic Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|
28
|
Kim BS, Ha HK, Lee IJ, Kim JH, Eun HW, Bae IY, Kim AY, Kim TK, Kim MH, Lee SK, Kang W. Accuracy of CT in local staging of gallbladder carcinoma. Acta Radiol 2002; 43:71-6. [PMID: 11972466 DOI: 10.1080/028418502127347475] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
PURPOSE To evaluate the accuracy of CT for staging gallbladder cancers, especially the T-factor of the TNM staging system. MATERIAL AND METHODS CT investigations of 100 patients with surgically proven gallbladder cancers were retrospectively analyzed. Dynamic helical CT was performed in 16 patients and conventional CT in the remaining 84. On CT, three radiologists attempted tumor staging for these patients; the majority opinion was used for final decision. According to CT protocols (dynamic helical CT vs. conventional CT) and each tumor type (thickened wall/intraluminal mass/massive), the accuracy of CT staging was compared. The CT staging was correlated with the surgico-pathologic results. RESULTS The overall accuracy of CT for staging gallbladder cancers was 71%; it was 79% for T1 and T2 tumors, 46% for T3 tumors, and 73% for T4 tumors. For all three readers, the poorest accuracy was obtained in T3 tumors. No statistically significant difference was noted in the accuracy between the groups undergoing conventional CT and dynamic helical CT. A statistically significant difference was noted in the accuracy for staging thickened wall and intraluminal mass types of tumors (p<0.05); the highest accuracy was obtained in the intraluminal mass type (89%) and the massive type (83%), while it was 54% in the thickened wall type. CONCLUSION The accuracy of tumor staging with CT in patients with gallbladder cancer depends on the morphological type of tumor. The poorest result is obtained in the thickened wall type.
Collapse
Affiliation(s)
- B S Kim
- Department of Diagnostic Radiology, University of Ulsan, Asan Medical Center, 388-1 Poongnap-dong, Songpa-ku, Seoul 138-736, Korea
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Kim JH, Kim TK, Kim BS, Eun HW, Kim PN, Lee MG, Ha HK. Enhancement of hepatic hemangiomas with levovist on coded harmonic angiographic ultrasonography. J Ultrasound Med 2002; 21:141-148. [PMID: 11833870 DOI: 10.7863/jum.2002.21.2.141] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To evaluate the pattern of contrast enhancement with Levovist on coded harmonic angiographic ultrasonography of hepatic hemangiomas. METHODS Twenty hemangiomas were evaluated with coded harmonic angiographic ultrasonography and a microbubble contrast agent. Verification of the diagnosis of a hemangioma was made by means of dynamic computed tomography (n = 8), dynamic magnetic resonance imaging (n = 1), radionuclide scanning (n = 6), or follow-up ultrasonography (n = 5). Ultrasonographic images were obtained before contrast agent administration and with a bolus injection of 2.5 g of a microbubble contrast agent (300 mg/mL Levovist; Schering AG, Berlin, Germany) every 10 to 15 seconds for 5 minutes. The contrast enhancement patterns of the 20 hemangiomas were assessed. RESULTS The tumor diameters as measured on ultrasonography were 7 to 97 mm (mean, 26.7 mm). Of the 20 hemangiomas, peripheral globular enhancement with progressive centripetal fill-in was shown in 15 (75%), rimlike enhancement with progressive centripetal fill-in was shown in 2 (10%), and homogeneous enhancement was shown in 1 (5%). In the remaining 2 lesions (10%), the enhancement patterns could not be seen, because they were not found on coded harmonic angiographic ultrasonography. CONCLUSIONS Coded harmonic angiographic ultrasonography with a microbubble contrast agent can depict the typical enhancement pattern in most hepatic hemangiomas.
Collapse
Affiliation(s)
- Jung Hoon Kim
- Department of Diagnostic Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|