1
|
Adleberg J, Benitez CL, Primiano N, Patel A, Mogel D, Kalra R, Adhia A, Berns M, Chin C, Tanghe S, Yi P, Zech J, Kohli A, Martin-Carreras T, Corcuera-Solano I, Huang M, Ngeow J. Fully Automated Measurement of the Insall-Salvati Ratio with Artificial Intelligence. J Imaging Inform Med 2024; 37:601-610. [PMID: 38343226 PMCID: PMC11031523 DOI: 10.1007/s10278-023-00955-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/17/2023] [Accepted: 09/19/2023] [Indexed: 04/20/2024]
Abstract
Patella alta (PA) and patella baja (PB) affect 1-2% of the world population, but are often underreported, leading to potential complications like osteoarthritis. The Insall-Salvati ratio (ISR) is commonly used to diagnose patellar height abnormalities. Artificial intelligence (AI) keypoint models show promising accuracy in measuring and detecting these abnormalities.An AI keypoint model is developed and validated to study the Insall-Salvati ratio on a random population sample of lateral knee radiographs. A keypoint model was trained and internally validated with 689 lateral knee radiographs from five sites in a multi-hospital urban healthcare system after IRB approval. A total of 116 lateral knee radiographs from a sixth site were used for external validation. Distance error (mm), Pearson correlation, and Bland-Altman plots were used to evaluate model performance. On a random sample of 2647 different lateral knee radiographs, mean and standard deviation were used to calculate the normal distribution of ISR. A keypoint detection model had mean distance error of 2.57 ± 2.44 mm on internal validation data and 2.73 ± 2.86 mm on external validation data. Pearson correlation between labeled and predicted Insall-Salvati ratios was 0.82 [95% CI 0.76-0.86] on internal validation and 0.75 [0.66-0.82] on external validation. For the population sample of 2647 patients, there was mean ISR of 1.11 ± 0.21. Patellar height abnormalities were underreported in radiology reports from the population sample. AI keypoint models consistently measure ISR on knee radiographs. Future models can enable radiologists to study musculoskeletal measurements on larger population samples and enhance our understanding of normal and abnormal ranges.
Collapse
Affiliation(s)
- J Adleberg
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
| | - C L Benitez
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - N Primiano
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - A Patel
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - D Mogel
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - R Kalra
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - A Adhia
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - M Berns
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - C Chin
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - S Tanghe
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - P Yi
- University of Maryland, Baltimore, MD, USA
| | - J Zech
- Columbia University Medical Center, New York, NY, USA
| | - A Kohli
- UT Southwestern, Dallas, TX, USA
| | | | - I Corcuera-Solano
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - M Huang
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - J Ngeow
- Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| |
Collapse
|
2
|
Corcuera-Solano I, Doshi A, Pawha PS, Gui D, Gaddipati A, Tanenbaum L. Quiet PROPELLER MRI techniques match the quality of conventional PROPELLER brain imaging techniques. AJNR Am J Neuroradiol 2015; 36:1124-7. [PMID: 25678482 DOI: 10.3174/ajnr.a4235] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Accepted: 12/05/2014] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Switching of magnetic field gradients is the primary source of acoustic noise in MR imaging. Sound pressure levels can run as high as 120 dB, capable of producing physical discomfort and at least temporary hearing loss, mandating hearing protection. New technology has made quieter techniques feasible, which range from as low as 80 dB to nearly silent. The purpose of this study was to evaluate the image quality of new commercially available quiet T2 and quiet FLAIR fast spin-echo PROPELLER acquisitions in comparison with equivalent conventional PROPELLER techniques in current day-to-day practice in imaging of the brain. MATERIALS AND METHODS Thirty-four consecutive patients were prospectively scanned with quiet T2 and quiet T2 FLAIR PROPELLER, in addition to spatial resolution-matched conventional T2 and T2 FLAIR PROPELLER imaging sequences on a clinical 1.5T MR imaging scanner. Measurement of sound pressure levels and qualitative evaluation of relative image quality was performed. RESULTS Quiet T2 and quiet T2 FLAIR were comparable in image quality with conventional acquisitions, with sound levels of approximately 75 dB, a reduction in average sound pressure levels of up to 28.5 dB, with no significant trade-offs aside from longer scan times. CONCLUSIONS Quiet FSE provides equivalent image quality at comfortable sound pressure levels at the cost of slightly longer scan times. The significant reduction in potentially injurious noise is particularly important in vulnerable populations such as children, the elderly, and the debilitated. Quiet techniques should be considered in these special situations for routine use in clinical practice.
Collapse
Affiliation(s)
- I Corcuera-Solano
- From the Neuroradiology Section, Department of Radiology (I.C.-S., A.D., P.S.P., L.T.), Icahn School of Medicine at Mount Sinai Hospital, Radiology, New York, New York
| | - A Doshi
- From the Neuroradiology Section, Department of Radiology (I.C.-S., A.D., P.S.P., L.T.), Icahn School of Medicine at Mount Sinai Hospital, Radiology, New York, New York
| | - P S Pawha
- From the Neuroradiology Section, Department of Radiology (I.C.-S., A.D., P.S.P., L.T.), Icahn School of Medicine at Mount Sinai Hospital, Radiology, New York, New York
| | - D Gui
- GE Healthcare (D.G., A.G.), Milwaukee, Wisconsin
| | - A Gaddipati
- GE Healthcare (D.G., A.G.), Milwaukee, Wisconsin
| | - L Tanenbaum
- From the Neuroradiology Section, Department of Radiology (I.C.-S., A.D., P.S.P., L.T.), Icahn School of Medicine at Mount Sinai Hospital, Radiology, New York, New York
| |
Collapse
|
3
|
Corcuera-Solano I, McLellan AM, Doshi AH, Pawha PS, Tanenbaum LN. Whole-brain adaptive 70-kVp perfusion imaging with variable and extended sampling improves quality and consistency while reducing dose. AJNR Am J Neuroradiol 2014; 35:2045-51. [PMID: 25034777 DOI: 10.3174/ajnr.a4043] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Despite common use of CTP to assess cerebral hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim was to evaluate the efficacy of an adaptive 70-kVp (peak) whole-brain CTP protocol with variable sampling intervals and extended duration against an established fixed-sampling, limited-period protocol at 80 kVp. MATERIALS AND METHODS A retrospective analysis of 37 patients with stroke scanned with conventional (n = 17) and variant-protocol (n = 20) whole-brain CTP was performed. We compared radiation dose, parametric map quality, and consistency of full-contrast circulation capture between a modified 70-kVp protocol, with 20 whole-brain passes at variable sampling intervals over an extended sampling period, and a conventional 80-kVp CTP examination with 24 passes at fixed-sampling intervals and a more limited scanning window. Mann-Whitney U test analysis was used to compare both protocols. RESULTS The 70-kVp CTP scan provided superior image quality at a 45% lower CT dose index volume and 13% lower dose-length product/effective dose compared with the conventional 80-kVp scan. With respect to the consistency of contrast-passage capture, 95% of the adaptive, extended protocol continued through the venous return to baseline, compared with only 47% by using the conventional limited-length protocol. Rapid sampling during the critical arterial arrival and washout period was accomplished in nearly 95% with both the variable and fixed-sampling-interval protocols. CONCLUSIONS Seventy-kilovolt (peak) CTP with variable and extended sampling produces improved image quality at lower radiation doses with greater consistency of full contrast passage capture.
Collapse
Affiliation(s)
- I Corcuera-Solano
- From the Department of Neuroradiology, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, New York
| | - A M McLellan
- From the Department of Neuroradiology, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, New York
| | - A H Doshi
- From the Department of Neuroradiology, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, New York
| | - P S Pawha
- From the Department of Neuroradiology, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, New York
| | - L N Tanenbaum
- From the Department of Neuroradiology, Mount Sinai Medical Center, One Gustave L. Levy Place, New York, New York.
| |
Collapse
|
4
|
Corcuera-Solano I, Doshi AH, Noor A, Tanenbaum LN. Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance. AJNR Am J Neuroradiol 2014; 35:1281-7. [PMID: 24557704 DOI: 10.3174/ajnr.a3861] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Patients in the neurosurgical intensive care unit undergo multiple head CT scans, resulting in high cumulative radiation exposures. Our aim was to assess the acceptability of a dedicated, special-purpose sinogram-affirmed iterative reconstruction-based ultra-low-dose CT protocol for neurosurgical intensive care unit surveillance head CT examinations, comparing image quality with studies performed with our standard-of-care sinogram-affirmed iterative reconstruction low-dose CT and legacy filtered back-projection standard-dose CT protocols. MATERIAL AND METHODS A retrospective analysis was performed of 54 head CT examinations: ultra-low-dose CT (n = 22), low-dose CT (n = 12), and standard-dose CT (n = 20) in 22 patients in the neurosurgical intensive care unit. Standard-dose CT was reconstructed by using filtered back-projection on a Somatom Sensation 64 scanner. Ultra-low-dose CT and ultra-low-dose CT examinations were performed on a Siemens AS+128 scanner with commercially available sinogram-affirmed iterative reconstruction. Qualitative and quantitative parameters, including image quality and dose, were evaluated. RESULTS Sinogram-affirmed iterative reconstruction ultra-low-dose CT represented a 68% lower dose index volume compared with filtered back-projection standard-dose CT techniques in the same patients while maintaining similar quality and SNR levels. Sinogram-affirmed iterative reconstruction low-dose CT offered higher image quality than filtered back-projection standard-dose CT (P < .05) with no differences in SNR at a 24% lower dose index volume. Compared with low-dose CT, ultra-low-dose CT had significantly lower SNR (P = .001) but demonstrated clinically satisfactory measures of image quality. CONCLUSIONS In this cohort of patients in the neurosurgical intensive care unit, dedicated ultra-low-dose CT for surveillance head CT imaging led to a significant dose reduction while maintaining adequate image quality.
Collapse
Affiliation(s)
- I Corcuera-Solano
- From the Department of Neuroradiology, The Mount Sinai Medical Center, New York, New York
| | - A H Doshi
- From the Department of Neuroradiology, The Mount Sinai Medical Center, New York, New York
| | - A Noor
- From the Department of Neuroradiology, The Mount Sinai Medical Center, New York, New York
| | - L N Tanenbaum
- From the Department of Neuroradiology, The Mount Sinai Medical Center, New York, New York.
| |
Collapse
|
5
|
Ng SA, Corcuera-Solano I, Gurudutt VV, Som PM. A rare case of Reidel thyroiditis with associated vocal cord paralysis: CT and MR imaging features. AJNR Am J Neuroradiol 2011; 32:E201-2. [PMID: 21454406 PMCID: PMC7964396 DOI: 10.3174/ajnr.a2406] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2010] [Accepted: 09/19/2010] [Indexed: 11/07/2022]
Abstract
Reidel thyroiditis is extremely rare and not only involves the thyroid gland but usually extends to neighboring structures in the neck. A rare complication of this disease is entrapment of the recurrent laryngeal nerve causing a vocal cord paralysis. In fact, to our knowledge, this is likely the only benign thyroid disease to cause such a paralysis. We present a case of a 57-year-old woman with Reidel thyroiditis and a recurrent laryngeal nerve paralysis. The CT and MR imaging features are presented as well as a brief review of this disease.
Collapse
Affiliation(s)
- S A Ng
- Department of Radiology, MountSinai School of Medicine of New York University, New York, NY, USA
| | | | | | | |
Collapse
|