Heggie JCP, Barnes P, Cartwright L, Diffey J, Tse J, Herley J, McLean ID, Thomson FJ, Grewal RK, Collins LT. Position paper: recommendations for a digital mammography quality assurance program V4.0. Australas Phys Eng Sci Med 2017; 40:491-543. [PMID: 28914430 DOI: 10.1007/s13246-017-0583-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Indexed: 12/21/2022]
Abstract
In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed quality control (QC) tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Version 2.0 represented the first of these updates and key changes related to image quality evaluation, ghost image evaluation and interpretation of signal to noise ratio measurements. In Version 3.0 some significant changes, made in light of further experience gained in testing digital mammography equipment were introduced. In Version 4.0, further changes have been made, most notably digital breast tomosynthesis (DBT) testing and QC have been addressed. Some additional testing for conventional projection imaging has been added in order that sites may have the capability to undertake dose surveys to confirm compliance with diagnostic reference levels (DRLs) that may be established at the National or State level. A key recommendation is that dosimetry calculations are now to be undertaken using the methodology of Dance et al. Some minor changes to existing facility QC tests have been made to ensure the suggested procedures align with those most recently adopted by the Royal Australian and New Zealand College of Radiologists and BreastScreen Australia. Future updates of this document may be provided as deemed necessary in electronic format on the ACPSEM's website ( https://www.acpsem.org.au/whatacpsemdoes/standards-position-papers and see also http://www.ranzcr.edu.au/quality-a-safety/radiology/practice-quality-activities/mqap ).
Collapse
Affiliation(s)
| | - P Barnes
- I-Med Radiology Network, Head office Melbourne, Melbourne, Australia
| | - L Cartwright
- Medical Physics Department, Westmead Hospital, Westmead, Australia
| | - J Diffey
- Hunter New England Imaging, John Hunter Hospital, New Lambton Heights, Australia
| | - J Tse
- Medical Physics and Radiation Engineering, Canberra Hospital, Canberra, Australia
| | - J Herley
- Radiation Protection Services Pty Ltd, Brisbane, Australia
| | - I D McLean
- Medical Physics and Radiation Engineering, Canberra Hospital, Canberra, Australia
| | - F J Thomson
- Radiological Physics Consultants Ltd, Warrington, New Zealand
| | - R K Grewal
- Medical Physics Department, Westmead Hospital, Westmead, Australia
| | - L T Collins
- Medical Physics Department, Westmead Hospital, Westmead, Australia
| |
Collapse
|
2
|
Nelson VK, Holloway L, McLean ID. The application of thermoluminescence dosimetry in X-ray energy discrimination. Australas Phys Eng Sci Med 2015; 38:543-9. [PMID: 26330215 DOI: 10.1007/s13246-015-0374-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Accepted: 08/25/2015] [Indexed: 11/26/2022]
Abstract
Clinical dosimetry requires an understanding of radiation energy to accurately determine the delivered dose. For many situations this is known, however there are also many situations where the radiation energy is not well known, thus limiting dosimetric accuracy. This is the case in personnel dosimetry where thermo luminescent (TL) dosimetry is the method of choice. Traditionally beam energy characteristics in personnel dosimetry are determined through discrimination with the use of various filters fitted within a radiation monitor. The presence of scattered and characteristic radiation produced by these metallic filters, however, can compromise the results. In this study the TL response of five materials TLD100, TLD100H, TLD200, TLD400 and TLD500, was measured at various X-ray energies. The TL sensitivity ratio for various combinations of materials as a function of X-ray energy was calculated. The results indicate that in personal dosimetry a combination of three or more TL detector system has a better accuracy of estimation of effective radiation energy of an X-ray beam than some of the current method of employed for energy estimation and has the potential to improve the accuracy in dose determination in a variety of practical situations. The development of this method also has application in other fields including quality assurance of the orthovoltage therapy machines, dosimetry intercomparisons of kilovoltage X-ray beams, and measurement of the dose to critical organs outside a treatment field of a megavoltage therapy beam.
Collapse
Affiliation(s)
- V K Nelson
- Liverpool and Macarthur Cancer Therapy Centres, Therry Road, Campbelltown, NSW, 2560, Australia.
| | - L Holloway
- Liverpool and Macarthur Cancer Therapy Centres, Therry Road, Campbelltown, NSW, 2560, Australia
- Institute of Medical Physics, Sydney University, Sydney, NSW, 2000, Australia
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, 2560, Australia
| | - I D McLean
- Medical Physics Department, Canberra Hospital, Garran, ACT, 2605, Australia
| |
Collapse
|
3
|
McLean ID. Suspension criteria for dual energy X ray absorptiometry. Radiat Prot Dosimetry 2013; 153:227-229. [PMID: 23169815 DOI: 10.1093/rpd/ncs298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The use of dual-energy X-ray absorptiometry (DXA) units primarily for the assessment of fracture risk and in the diagnosis of osteoporosis is ubiquitous in Europe and ever-expanding in its implementation worldwide. DXA is known for its reported low radiation dose and precision in the determination of bone mineral density. However, the use of simple suspension criteria, as proposed in the new EC report RP-162, will identify units that are unfit for useful and safe diagnosis. Such suspension levels, however, are not a substitute for regular maintenance, quality control testing and optimisation of clinical outcomes.
Collapse
Affiliation(s)
- I D McLean
- Medical Physics and Radiation Engineering, Canberra Hospital, Garran, ACT 2605, Australia
| |
Collapse
|
4
|
Faulkner K, Järvinen H, Butler P, McLean ID, Pentecost M, Rickard M, Abdullah B. A clinical audit programme for diagnostic radiology: the approach adopted by the International Atomic Energy Agency. Radiat Prot Dosimetry 2010; 139:418-21. [PMID: 20159920 DOI: 10.1093/rpd/ncq002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The International Atomic Energy Agency (IAEA) has a mandate to assist member states in areas of human health and particularly in the use of radiation for diagnosis and treatment. Clinical audit is seen as an essential tool to assist in assuring the quality of radiation medicine, particularly in the instance of multidisciplinary audit of diagnostic radiology. Consequently, an external clinical audit programme has been developed by the IAEA to examine the structure and processes existent at a clinical site, with the basic objectives of: (1) improvement in the quality of patient care; (2) promotion of the effective use of resources; (3) enhancement of the provision and organisation of clinical services; (4) further professional education and training. These objectives apply in four general areas of service delivery, namely quality management and infrastructure, patient procedures, technical procedures and education, training and research. In the IAEA approach, the audit process is initiated by a request from the centre seeking the audit. A three-member team, comprising a radiologist, medical physicist and radiographer, subsequently undertakes a 5-d audit visit to the clinical site to perform the audit and write the formal audit report. Preparation for the audit visit is crucial and involves the local clinical centre completing a form, which provides the audit team with information on the clinical centre. While all main aspects of clinical structure and process are examined, particular attention is paid to radiation-related activities as described in the relevant documents such as the IAEA Basic Safety Standards, the Code of Practice for Dosimetry in Diagnostic Radiology and related equipment and quality assurance documentation. It should be stressed, however, that the clinical audit does not have any regulatory function. The main purpose of the IAEA approach to clinical audit is one of promoting quality improvement and learning. This paper describes the background to the clinical audit programme and the IAEA clinical audit protocol.
Collapse
Affiliation(s)
- K Faulkner
- Quality Assurance Reference Centre, Unit 9, Kingfisher Way, Wallsend, Tyne and Wear NE28 9ND, UK.
| | | | | | | | | | | | | |
Collapse
|
5
|
McLean ID, Heggie JCP, Herley J, Thomson FJ, Grewal RK. Interim recommendations for a digital mammography quality assurance program. Australas Phys Eng Sci Med 2007; 30:65-100. [PMID: 17682397 DOI: 10.1007/bf03178412] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed Quality Control tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Accordingly, updates of this document will be provided as deemed necessary in electronic format on the ACPSEM's website (see http://www.acpsem.org.au/au/subgroup/radiology/RadiologySG_index.html).
Collapse
Affiliation(s)
- I D McLean
- Medical Physics Department, Westmead Hospital, Wentworthville, Australia.
| | | | | | | | | |
Collapse
|
6
|
Grewal RK, McLean ID. Comparative evaluation of an II based and a flat panel based cardiovascular fluoroscopy system within a clinical environment. Australas Phys Eng Sci Med 2005; 28:151-8. [PMID: 16250468 DOI: 10.1007/bf03178708] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The image quality and dose parameters from a 2004 Siemens Axiom Artis dBC cardiac biplane with flat panel detector were evaluated and compared to similar parameters evaluated for a 1977 Toshiba DPF 2000A biplane cardiac unit with a conventional image intensifier. Image quality assessment was performed with the Westmead test object; using solid water as a patient equivalent absorber. The patient dose comparison of the two systems is based on dose area product meter readings for 1512 patient cases recorded over 6 months following installation of the Siemens flat panel digital unit. The image quality results indicate that: (a) high contrast resolution was better with the digital flat panel unit, (b) low contrast resolution is similar between systems, and (c) the threshold contrast of the flat panel system is the same or inferior to that of the image intensifier system. Input dose to the surface of the flat panel detector showed a strong dependence on field size, similar to the behaviour of image intensifier system. For the most common clinical procedure--Left Heart Study via Judkins--the average total dose area product reading was 64.0 Gy-cm2 against 67.7 Gy-cm2 for the digital and conventional units respectively (p = 0.27) indicating no significant difference in dose performance between the two x-ray machines.
Collapse
Affiliation(s)
- R K Grewal
- Medical Physics Department, Westmead Hospital, Westmead, Australia.
| | | |
Collapse
|
7
|
Craig AR, Heggie JC, McLean ID, Coakley KS, Nicoll JJ. Recommendations for a mammography quality assurance program. Australas Phys Eng Sci Med 2001; 24:107-31. [PMID: 11764394 DOI: 10.1007/bf03178354] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
In 1989 the ACPSEM published a position paper entitled "A Quality Assurance Programme for Mass Screening in Mammography". This paper described test parameters and performance specifications for the equipment related aspects of a mammography quality assurance program. Advice on test equipment selection was also provided. In the intervening period of time there have been considerable advances in mammography technology creating a need to review a number of the paper's recommendations. There have also been considerable developments in the mammography quality assurance (QA) field, not the least of which includes the American College of Radiology Mammography Accreditation Program (ACR-MAP) and the similarly structured Royal Australian and New Zealand College of Radiologists' Mammography Accreditation Program (RANZCR-MAP). In light of these developments it was decided by the Radiology Interest Group to review the ACPSEM position on those aspects of mammography QA that fall within the medical physicist's area of expertise. This document represents the outcome of those deliberations.
Collapse
Affiliation(s)
- A R Craig
- Biomedical Technology Services, Royal Brisbane Hospital, Herston, QLD.
| | | | | | | | | |
Collapse
|
8
|
Abstract
Osteochondritis dissecans of the patellofemoral joint is an uncommon condition that may be the cause of anterior knee pain or crepitus. We present the clinical features of 37 patients with osteochondritis dissecans lesions of the patellofemoral joint (24 on the patella, 13 on the trochlear groove), including two patients with medial trochlear groove lesions, which have not, to our knowledge, been previously reported. The osteochondral lesions involved the convex articular surfaces. The median age of patients when first examined was 15 years, and 54% of patients had open epiphyses. These lesions were more common in male patients than in female patients (four-to-one ratio). Osteochondritis dissecans of the patellofemoral joint can be overlooked unless quality radiographs are viewed with care and, at arthroscopy, both the patella and trochlear groove are assessed. Treatment depends on the symptoms, site, and nature of the lesion and the patient's age. Nonoperative management includes patellar taping and vastus medialis obliquus muscle exercises. Operative intervention is indicated for patients with mechanical symptoms and includes arthroscopy, consisting of chondroplasty and removal of loose bodies, and lateral retinacular release. In this study treatment generally improved the symptoms, but patients with articular cartilage loss had persistent patellofemoral crepitus and discomfort.
Collapse
Affiliation(s)
- T A Peters
- Prahran Sports Medicine Centre, Victoria, Australia
| | | |
Collapse
|
9
|
Ng GY, Oakes BW, Deacon OW, McLean ID, Eyre DR. Long-term study of the biochemistry and biomechanics of anterior cruciate ligament-patellar tendon autografts in goats. J Orthop Res 1996; 14:851-6. [PMID: 8982125 DOI: 10.1002/jor.1100140602] [Citation(s) in RCA: 53] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This study examined the change in type-III collagen concentration and hydroxypyridinium crosslink density of anterior cruciate ligament-patellar tendon autografts and their correlations with Young's modulus of the anterior cruciate autografts and anterior cruciate controls for as long as 3 years after surgery. Fifteen adult female goats (two control and 13 experimental) were tested. Each experimental animal received an anterior cruciate ligament-patellar tendon autograft to the right knee. These animals were tested at 0 (n = 2), 6 (n = 2), 12 (n = 2), and 24 (n = 1) weeks and 1 (n = 3) and 3 (n = 3) years after surgery. After mechanical testing, the anterior cruciate autograft and control tissues were analysed for type-III collagen concentration and hydroxypyridinium crosslink density. The results of sodium dodecyl sulfate gel electrophoresis showed a trend of initial increase in the percentage of type-III collagen in the anterior cruciate ligament autografts and a subsequent decrease after 24 weeks following surgery. There was a nonsignificant (p > 0.05) negative correlation between type-III collagen concentration and Young's modulus. The hydroxypyridinium crosslink density was highest at 1 year after surgery. There was a significant (p < 0.05) positive correlation between hydroxypyridinium crosslink density and Young's modulus in the anterior cruciate autografts and controls. This suggests that hydroxypyridinium crosslink density has a good linear relationship with the material strength of the anterior cruciate ligament autograft and hence could be used as an objective guide for rehabilitation with anterior cruciate autografts.
Collapse
Affiliation(s)
- G Y Ng
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hung Hom, Kowloon
| | | | | | | | | |
Collapse
|
10
|
Ng GY, Oakes BW, McLean ID, Deacon OW, Lampard D. The long-term biomechanical and viscoelastic performance of repairing anterior cruciate ligament after hemitransection injury in a goat model. Am J Sports Med 1996; 24:109-17. [PMID: 8638743 DOI: 10.1177/036354659602400120] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
To test the healing of the partially torn anterior cruciate ligament, we transected the posterolateral bundle in 11 adult female goats and tested the ligaments at 12, 24, and 52 weeks and 3 years after surgery. As early as 12 weeks after surgery translucent fibrous tissue covered the wound. The differences in anteroposterior laxity between right and left knees measured at 45 degrees and 90 degrees of flexion were not significantly different at each period. Results of Instron testing of the posterolateral bundle revealed the normalized changes in load-relaxation and Young's modulus were not significantly different at each period, but the ultimate tensile strength and stiffness at 3 years were significantly higher than at 12 weeks (P < 0.05) Failure started at the repair site for the 12-week group, but at 24 and 52 weeks the failure occurred throughout the ligament. At 3 years, the specimens failed with bony avulsion, indicating the repaired tissue was not the weakest link of the bone-ligament-bone complex. This study shows that under favorable conditions, partial anterior cruciate ligament injuries are capable of repair. What is more important, the high ultimate tensile strength and stiffness of the 3-year repaired tissue indicate full structural repair of such an artificial transection injury may be possible.
Collapse
Affiliation(s)
- G Y Ng
- Department of Rehabilitation Sciences, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong
| | | | | | | | | |
Collapse
|
11
|
Ng GY, Oakes BW, Deacon OW, McLean ID, Lampard D. Biomechanics of patellar tendon autograft for reconstruction of the anterior cruciate ligament in the goat: three-year study. J Orthop Res 1995; 13:602-8. [PMID: 7674076 DOI: 10.1002/jor.1100130416] [Citation(s) in RCA: 71] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This study examined the biomechanics of anterior cruciate ligament-patellar tendon autografts for as long as 3 years after surgery. Twenty-seven adult female goats were tested; four served as controls and the others received an autograft to the right knee with each left knee serving as an additional control. The animals with grafts were tested at 0 week (n = 4), 6 weeks (n = 4), 12 weeks (n = 4), 24 weeks (n = 3), 1 year (n = 5), and 3 years (n = 3) after surgery. The anteroposterior laxity of the knee joint, load-relaxation, and structural and material properties of the graft were tested. The anteroposterior laxity was significantly greater than that of the controls for all groups except at 3 years. Load-relaxation was greater than that of the control anterior cruciate ligaments, but in the 1 and 3-year grafts load-relaxation was less than that of the patellar tendons with 5 minutes of sustained loading. Between 12 and 52 weeks, the stiffness and modulus of the grafts increased 3-fold, but the improvement was slow afterward. At 3 years, the strength and stiffness of the grafts were 44 and 49% those of the control ligaments, respectively; the modulus was 37 and 46% that of the control anterior cruciate ligaments and patellar tendons, respectively. The persistent inferior mechanical performance at 3 years suggests that anterior cruciate ligament grafts may never attain normal strength.
Collapse
Affiliation(s)
- G Y Ng
- Department of Anatomy, Faculty of Medicine, Monash University, Clayton, Victoria, Australia
| | | | | | | | | |
Collapse
|
12
|
McLean ID, Collins LT. Some DSA testing methods and an evaluation of eight available units. Australas Radiol 1989; 33:259-65. [PMID: 2604636 DOI: 10.1111/j.1440-1673.1989.tb03286.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Eight DSA units in the Sydney region were evaluated by a set of simple performance tests. Low contrast resolution and iodine sensitivity tests exhibited the most variation between the six fully tested units. A range of performance levels was measured. Four of the eight units required adjustment by the manufacturers' service engineer after testing. The evaluation of those units considered satisfactory by both the manufacturers and the operators indicated that the fully interfaced, integral units gave better results than the earlier 'add on' units.
Collapse
|
13
|
McLean ID. kVp definitions and their impact on practical kVp measurement in diagnostic radiology. Australas Phys Eng Sci Med 1987; 10:107-9. [PMID: 3662971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
14
|
McLean ID. Swimmers' injuries. Aust Fam Physician 1984; 13:499-502. [PMID: 6148925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Swimming is an excellent sport for people of all age groups but can produce overuse injuries. Early diagnosis is essential before the resistant stage is reached: a swimmer with shoulder pain cannot 'swim it out'. Swimmers have different tolerances to high levels of activity but injuries can be reduced if attention is paid to technique, preliminary warm up and stretching exercises. Training errors and faulty technique cause problems but psychological stress in the teenage group should not be overlooked.
Collapse
|