Romero-Zayas I, Campos Añón F, Santos Virosta M, Cordón del Pozo J, Santos Montero C, Niñerola Baizán A, Fuster D. Implementación del análisis modal de fallos y efectos en una Unidad de Radiofarmacia Hospitalaria. Rev Esp Med Nucl Imagen Mol 2022. [DOI: 10.1016/j.remn.2021.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
2
|
Romero-Zayas I, Campos Añón F, Santos Virosta M, Cordón Del Pozo J, Santos Montero C, Niñerola Baizán A, Fuster D. Implementation of the failure modes and effects analysis in a Hospital Radiopharmacy Unit. Rev Esp Med Nucl Imagen Mol 2022; 41:300-310. [PMID: 35668016 DOI: 10.1016/j.remnie.2022.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 12/02/2021] [Accepted: 12/11/2021] [Indexed: 11/26/2022]
Abstract
AIM The aim of this study is the implementation in a Hospital Radiopharmacy Unit of a risk analysis methodology in order to proactively identify possible failure modes and prioritize corrective measures. MATERIALS AND METHODS By means of the failure modes and effects analysis (FMEA), the possible failure modes of each of the stages of the processes of prescription, preparation, and administration of radiopharmaceuticals for diagnostic and therapy were identified. From the variables of severity, probability and detectability, the risk was quantified using the Risk Priority Number (RPN) for each failure mode, sub-process, and type of radiopharmaceutical. Improvement measures were established and the reduction in the RPN value was calculated. RESULTS A total of 96 failure modes were identified (58 for diagnostic radiopharmaceuticals and 38 for therapy). Biunivocal identification of the patient with the radiopharmaceutical is the failure mode with the highest RPN (60) and the radiolabeling cell sub-process the one that has the highest risk (RPN 286). As a result of the improvement measures, the overall RPN was reduced by 22% for diagnostic radiopharmaceuticals and 20% for therapy. This reduction would be 46% and 31% respectively if radiopharmacy software and a barcode technology in the administration were implemented. CONCLUSIONS The application of the FMEA methodology as a risk analysis tool allows to identify the critical points of the processes related to radiopharmaceuticals and prioritize measures to reduce the risk.
Collapse
Affiliation(s)
- I Romero-Zayas
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain.
| | - F Campos Añón
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain
| | - M Santos Virosta
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain
| | - J Cordón Del Pozo
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain
| | - C Santos Montero
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain
| | - A Niñerola Baizán
- Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona, Spain
| | - D Fuster
- Servicio de Medicina Nuclear, Hospital Clínic, Barcelona, Spain
| |
Collapse
|
3
|
Vollmer I, Sánchez-Izquierdo N, Martínez D, Sánchez-Lorente D, Casanueva-Eliceiry S, Boada M, Guirao Á, Romero-Zayas I, Vidal-Sicart S, Paredes P. Role of a portable gamma-camera with optical view for margins assessment of pulmonary nodules resected by radioguided surgery. Eur J Nucl Med Mol Imaging 2021; 49:361-370. [PMID: 34185137 DOI: 10.1007/s00259-021-05466-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 06/16/2021] [Indexed: 11/25/2022]
Abstract
PURPOSE Radioguided occult lesion localization (ROLL) of pulmonary nodules is an alternative to hook-wire. Both required of a histological margin assessment. The activity emerging from the radiotracer allows to obtain an intraoperative scintigraphic image of the surgical specimen by a portable gamma-camera (PGC) fitted with an optical view, which provides information about the localization of the nodule in relation to the margins. The aim of this study was to evaluate the intraoperative use of a PGC for margin assessment of pulmonary nodules. METHODS ROLL technique was used in 38 nodules (36 pulmonary, 1 chest wall, and 1 pleural nodules). A PGC intraoperative image of the surgical specimen was obtained in 32. Scintigraphic results were compared to the histological assessment. Other factors, such as nodule size, distance from the pleural surface, or distance covered by the needle, were considered as possible factors for non-centered lesions. RESULTS PGC images showed that the lesion was in contact with the margins in 8/32 cases and centered in 24. In all cases in which the lesion was considered as centered by the PGC, the margins were free of involvement (NPV 100%), although the PPV is low. CONCLUSIONS The use of a PGC for margin assessment after pulmonary nodule resection is feasible and provides a high NPV in our series. In addition, the short intraoperative time required for its use makes the PGC a useful tool for providing supplementary information to histopathologic results. Further studies from different surgical teams are required for an external validation.
Collapse
Affiliation(s)
- Ivan Vollmer
- Radiology Department, Hospital Clínic Barcelona, Barcelona, Spain
- Faculty of Medicine, University of Barcelona (UB), Barcelona, Spain
| | | | - Daniel Martínez
- Faculty of Medicine, University of Barcelona (UB), Barcelona, Spain
- Pathology Department, Hospital Clínic Barcelona, Barcelona, Spain
| | - David Sánchez-Lorente
- Faculty of Medicine, University of Barcelona (UB), Barcelona, Spain
- Thoracic Surgery Department, Hospital Clínic Barcelona, Barcelona, Spain
| | | | - Marc Boada
- Thoracic Surgery Department, Hospital Clínic Barcelona, Barcelona, Spain
| | - Ángela Guirao
- Thoracic Surgery Department, Hospital Clínic Barcelona, Barcelona, Spain
| | | | - Sergi Vidal-Sicart
- Nuclear Medicine Department, Hospital Clínic Barcelona, Barcelona, Spain
- Institut D'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Villarroel 170, 08036, Barcelona, Spain
| | - Pilar Paredes
- Faculty of Medicine, University of Barcelona (UB), Barcelona, Spain.
- Nuclear Medicine Department, Hospital Clínic Barcelona, Barcelona, Spain.
- Institut D'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Villarroel 170, 08036, Barcelona, Spain.
| |
Collapse
|
4
|
Reynés-Llompart G, Gámez-Cenzano C, Romero-Zayas I, Rodríguez-Bel L, Vercher-Conejero JL, Martí-Climent JM. Performance Characteristics of the Whole-Body Discovery IQ PET/CT System. J Nucl Med 2017; 58:1155-1161. [PMID: 28302761 DOI: 10.2967/jnumed.116.185561] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Accepted: 02/27/2017] [Indexed: 12/22/2022] Open
Abstract
The aim of this study was to assess the physical performance of a new PET/CT system, the Discovery IQ with 5-ring detector blocks. Methods: Performance was measured using the National Electrical Manufacturers Association NU2-2012 methodology. Image quality was extended by accounting for different acquisition parameters (lesion-to-background ratios [8:1, 4:1, and 2:1] and acquisition times) and reconstruction algorithms (VUE-point HD [VPHD], VPHD with point-spread-function modeling [VPHD-S], and Q.Clear). Tomographic reconstruction was also assessed using a Jaszczak phantom. Additionally, 30 patient lesions were analyzed to account for differences in lesion volume and SUV quantification between reconstruction algorithms. Results: Spatial resolution ranged from 4.2 mm at 1 cm to 8.5 mm at 20 cm. Sensitivity measured at the center and at 10 cm was 22.8 and 20.4 kps/kBq, respectively. The noise-equivalent counting rate peak was 124 kcps at 9.1 kBq/cm3 The scatter fraction was 36.2%. The accuracy of correction for count losses and randoms was 3.9%. In the image quality test, contrast recovery for VPHD, VPHD-S, and Q.Clear ranged from 18%, 18%, and 13%, respectively (hot contrast; 10-mm sphere diameter; ratio, 2:1), to 68%, 67%, and 81%, respectively (cold contrast; 37-mm sphere diameter; ratio, 8:1). Background variability ranged from 3.4%, 3.0%, and 2.1%, respectively (ratio, 2:1), to 5.5%, 4.8%, and 3.7%, respectively (ratio, 8:1). On Q.Clear reconstruction, the decrease in the penalty term (β) increased the contrast recovery coefficients and background variability. With the Jaszczak phantom, image quality increased overall when a reconstruction algorithm modeling the point-spread function was used, and use of Q.Clear increased the signal-to-noise ratio. Lesions analyzed using VPHD-S and Q.Clear had an SUVmean of 6.5 ± 3 and 7 ± 3, respectively (P < 0.01), and an SUVmax of 11 ± 4.8 and 12 ± 4, respectively (P < 0.01). No significant difference in mean lesion volume was found between algorithms. Conclusion: Among the various Discovery bismuth germanium oxide-based PET/CT scanners, the IQ with 5-ring detector blocks has the highest overall performance, with improved sensitivity and counting rate performance. Q.Clear reconstruction improves the PET image quality, with higher recovery coefficients and lower background variability.
Collapse
Affiliation(s)
- Gabriel Reynés-Llompart
- PET Unit, Nuclear Medicine Department, IDI, Hospital Universitari de Bellvitge, IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain; and
| | - Cristina Gámez-Cenzano
- PET Unit, Nuclear Medicine Department, IDI, Hospital Universitari de Bellvitge, IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain; and
| | - Inmaculada Romero-Zayas
- PET Unit, Nuclear Medicine Department, IDI, Hospital Universitari de Bellvitge, IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain; and
| | - Laura Rodríguez-Bel
- PET Unit, Nuclear Medicine Department, IDI, Hospital Universitari de Bellvitge, IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain; and
| | - José L Vercher-Conejero
- PET Unit, Nuclear Medicine Department, IDI, Hospital Universitari de Bellvitge, IDIBELL, L'Hospitalet de Llobregat, Barcelona, Spain; and
| | | |
Collapse
|
5
|
Roca M, Muñiz-Diaz E, Mora J, Romero-Zayas I, Ramón O, Roig I, Pujol-Moix N. The scintigraphic index spleen/liver at 30 minutes predicts the success of splenectomy in persistent and chronic primary immune thrombocytopenia. Am J Hematol 2011; 86:909-13. [PMID: 21948335 DOI: 10.1002/ajh.22147] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2011] [Revised: 07/08/2011] [Accepted: 07/13/2011] [Indexed: 11/09/2022]
Abstract
UNLABELLED Splenectomy is considered the second-line of treatment in patients with chronic primary immune thrombocytopenia (ITP) in whom glucocorticoids have failed. Some patients do not respond to splenectomy or they have postoperative complications. Based on our previous experience using kinetic and scintigraphic parameters, we did a retrospective study with the aim of comparing all these parameters as a means of predicting the success of splenectomy in persistent and chronic primary ITP. Forty-one consecutive patients with chronic primary ITP refractory to prednisone, who had been splenectomized, were included in the study. The response to splenectomy was assessed by evaluating bleeding and platelet counts before and at different times after surgery. A complete platelet kinetic study was performed before the splenectomy using autologous (111) In-labeled platelets. The scintigraphic parameters measured included different indices between spleen/heart, liver/hearth, and spleen/liver. Thirty-six patients gave a complete response after splenectomy and five patients did not respond. A statistically significant difference between both groups was found with initial platelet recovery and with some scintigraphic indices which also showed a variable prediction value for the success of splenectomy. Among these indices, the spleen/liver at 30 minutes demonstrated a predictive value with a 100% of sensitivity and a 100% of specificity. CONCLUSION some platelet kinetic parameters and scintigraphic indices, in particular the spleen/liver at 30 minutes, were useful to predict the outcome of splenectomy in persistent and chronic primary ITP and, therefore, they should be taken into account when deciding whether or not to perform a splenectomy.
Collapse
Affiliation(s)
- Manel Roca
- Department of Nuclear Medicine, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Spain
| | | | | | | | | | | | | |
Collapse
|