Gajdátsy G, Benedek F, Kokavecz J, Szabó G, Kornis J. Improved fiber optic device for in situ determination of electrolyte stratification in lead-acid batteries.
Rev Sci Instrum 2009;
80:125108. [PMID:
20059171 DOI:
10.1063/1.3272201]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A three-channel, highly sensitive, fiber optic device is presented to measure acid concentration in lead-acid batteries during their operation. The refractive index and thereby the concentration of sulfuric acid is measured by a bent, silica glass fiber tip, stripped off its cladding. Sensor heads of the device are small enough to be inserted at different positions in the cell of an ordinary, flooded lead-acid battery. Measuring the concentration of the electrolyte at different depths of the battery cell, acid stratification can be accurately determined. During the test of the instrument, about 0.3 Hz temporal and 0.05 wt % concentration resolutions were achieved while the temperature drift was found to be -0.25 wt %/degrees C.
Collapse