1
|
Gerlach S, Pinto M, Kurichiyanil N, Grau C, Hérault J, Hillbrand M, Poulsen PR, Safai S, Schippers JM, Schwarz M, Søndergaard CS, Tommasino F, Verroi E, Vidal M, Yohannes I, Schreiber J, Parodi K. Corrigendum: Beam characterization and feasibility study for a small animal irradiation platform at clinical proton therapy facilities (2020 Phys. Med. Biol.65 245045). Phys Med Biol 2021; 66. [PMID: 34037545 DOI: 10.1088/1361-6560/abf00e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 03/18/2021] [Indexed: 11/11/2022]
Affiliation(s)
- S Gerlach
- Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748 Garching, Germany
| | - M Pinto
- Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748 Garching, Germany
| | - N Kurichiyanil
- Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748 Garching, Germany
| | - C Grau
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.,Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - J Hérault
- Centre Antoine Lacassagne, Nice, France.,Fédération Claude Lalanne-Université Côte d'Azur, Nice, France
| | - M Hillbrand
- Rinecker Proton Therapy Center, München, Germany
| | - P R Poulsen
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.,Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - S Safai
- Paul Scherrer Institute, Villigen, Switzerland
| | | | - M Schwarz
- Trento Institute for Fundamental Physics and Applications, National Institute for Nuclear Physics, Povo, Italy.,Protontherapy Department, Azienda Provinciale per i Servizi Sanitari, Trento, Italy
| | - C S Søndergaard
- Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - F Tommasino
- Trento Institute for Fundamental Physics and Applications, National Institute for Nuclear Physics, Povo, Italy.,Department of Physics, University of Trento, Povo, Italy
| | - E Verroi
- Trento Institute for Fundamental Physics and Applications, National Institute for Nuclear Physics, Povo, Italy
| | - M Vidal
- Centre Antoine Lacassagne, Nice, France.,Fédération Claude Lalanne-Université Côte d'Azur, Nice, France
| | - I Yohannes
- Rinecker Proton Therapy Center, München, Germany
| | - J Schreiber
- Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748 Garching, Germany
| | - K Parodi
- Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748 Garching, Germany
| |
Collapse
|
2
|
Nesteruk KP, Bolsi A, Lomax AJ, Meer D, van de Water S, Schippers JM. A static beam delivery device for fast scanning proton arc-therapy. Phys Med Biol 2021; 66:055018. [PMID: 33498040 DOI: 10.1088/1361-6560/abe02b] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called 'arcs'). This technique can potentially yield a better dose conformity around the tumor and a very low dose in the surrounding healthy tissue. Currently, proton-arc therapy is performed by rotating a proton gantry around the patient, adapting the normally used dose-delivery method to the arc-specific motion of the gantry. Here we present first results from a feasibility study of the conceptual design of a new static fast beam delivery device/system for proton-arc therapy, which could be used instead of a gantry. In this novel concept, the incident angle of proton beams can be set rapidly by only changing field strengths of small magnets. This device eliminates the motion of the heavy gantry and related hardware. Therefore, a reduction of the total treatment time is expected. In the feasibility study presented here, we concentrate on the concept of the beam transport. Based on several simple, but realistic assumptions and approximations, proton tracking calculations were performed in a 3D magnetic field map, to calculate the beam transport in this device and to investigate and address several beam-optics challenges. We propose and simulate corresponding solutions and discuss their outcomes. To enable the implementation of some usually applied techniques in proton therapy, such as pencil beam scanning, energy modulation and beam shaping, we present and discuss our proposals. Here we present the concept of a new idea to perform fast proton arc-scanning and we report on first results of a feasibility study. Based on these results, we propose several options and next steps in the design.
Collapse
Affiliation(s)
- K P Nesteruk
- Paul Scherrer Institute, Villigen PSI, Switzerland
| | - A Bolsi
- Paul Scherrer Institute, Villigen PSI, Switzerland
| | - A J Lomax
- Paul Scherrer Institute, Villigen PSI, Switzerland.,Department of Physics, ETH Zurich, Switzerland
| | - D Meer
- Paul Scherrer Institute, Villigen PSI, Switzerland
| | | | | |
Collapse
|
3
|
Gerlach S, Pinto M, Kurichiyanil N, Grau C, Hérault J, Hillbrand M, Poulsen PR, Safai S, Schippers JM, Schwarz M, Søndergaard CS, Tommasino F, Verroi E, Vidal M, Yohannes I, Schreiber J, Parodi K. Beam characterization and feasibility study for a small animal irradiation platform at clinical proton therapy facilities. Phys Med Biol 2020; 65:245045. [DOI: 10.1088/1361-6560/abc832] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
4
|
Rizzoglio V, Adelmann A, Gerbershagen A, Meer D, Nesteruk KP, Schippers JM. Uncertainty quantification analysis and optimization for proton therapy beam lines. Phys Med 2020; 75:11-18. [PMID: 32473518 DOI: 10.1016/j.ejmp.2020.05.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 03/02/2020] [Accepted: 05/17/2020] [Indexed: 10/24/2022] Open
Abstract
Since many years proton therapy is an effective treatment solution against deep-seated tumors. A precise quantification of sources of uncertainty in each proton therapy aspect (e.g. accelerator, beam lines, patient positioning, treatment planning) is of profound importance to increase the accuracy of the dose delivered to the patient. Together with Monte Carlo techniques, a new research field called Uncertainty Quantification (UQ) has been recently introduced to verify the robustness of the treatment planning. In this work we present the first application of UQ as a method to identify typical errors in the transport lines of a cyclotron-based proton therapy facility and analyze their impact on the properties of the therapeutic beams. We also demonstrate the potential of UQ methods in developing optimized beam optics solutions for high-dimensional problems. Sensitivity analysis and surrogate models offer a fast way to exclude unimportant parameters frcomplex optimization problems such as the design of a superconducting gantry performed at Paul Scherrer Institute in Switzerland.
Collapse
Affiliation(s)
- V Rizzoglio
- Paul Scherrer Institut, 5232 Villigen, Switzerland; CERN, 1211 Geneva, Switzerland.
| | - A Adelmann
- Paul Scherrer Institut, 5232 Villigen, Switzerland.
| | - A Gerbershagen
- Paul Scherrer Institut, 5232 Villigen, Switzerland; CERN, 1211 Geneva, Switzerland
| | - D Meer
- Paul Scherrer Institut, 5232 Villigen, Switzerland
| | - K P Nesteruk
- Paul Scherrer Institut, 5232 Villigen, Switzerland
| | | |
Collapse
|
5
|
Nesteruk KP, Calzolaio C, Meer D, Rizzoglio V, Seidel M, Schippers JM. Large energy acceptance gantry for proton therapy utilizing superconducting technology. ACTA ACUST UNITED AC 2019; 64:175007. [DOI: 10.1088/1361-6560/ab2f5f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Abstract
An overview is given of different techniques of dose delivery applied in currently operating and planned particle therapy systems. Their advantages and disadvantages will be compared and consequences of the methods for the rest of the instrumentation will be discussed. The interrelationship between beam delivery at the patient and the accelerator system is shown by means of several concrete examples. Apart from a description of several subsystems in a particle therapy facility, design rules for optimizing the reliability of an accelerator and beam delivery system will be discussed, as well as some remarks concerning how to deal with future developments.
Collapse
|
7
|
Mumot M, Algranati C, Hartmann M, Schippers JM, Hug E, Lomax AJ. Proton range verification using a range probe: definition of concept and initial analysis. Phys Med Biol 2010; 55:4771-82. [DOI: 10.1088/0031-9155/55/16/010] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
8
|
van Goethem MJ, van der Meer R, Reist HW, Schippers JM. Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following a beam line. Phys Med Biol 2009; 54:5831-46. [DOI: 10.1088/0031-9155/54/19/011] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
9
|
Seravalli E, de Boer MR, Geurink F, Huizenga J, Kreuger R, Schippers JM, van Eijk CWE. 2D dosimetry in a proton beam with a scintillating GEM detector. Phys Med Biol 2009; 54:3755-71. [DOI: 10.1088/0031-9155/54/12/010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
10
|
Seravalli E, de Boer MR, Geurink F, Huizenga J, Kreuger R, Schippers JM, van Eijk CWE. Characterization of a scintillating GEM detector with low energy x-rays. Phys Med Biol 2008; 53:6195-209. [DOI: 10.1088/0031-9155/53/21/020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
11
|
van Luijk P, Schippers JM. We need to bridge the gap between current practice in mathematical modeling and new insights obtained from radiobiology: comment on Zhou et al. [Med. Phys. 34, 2807-2815 (2007)]. Med Phys 2008; 35:2558-9; author reply 2560. [PMID: 18649489 DOI: 10.1118/1.2912365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
12
|
Seravalli E, de Boer M, Geurink F, Huizenga J, Kreuger R, Schippers JM, van Eijk CWE, Voss B. A scintillating gas detector for 2D dose measurements in clinical carbon beams. Phys Med Biol 2008; 53:4651-65. [DOI: 10.1088/0031-9155/53/17/013] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
13
|
Schippers JM, Duppich J, Goitein G, Jermann M, Lomax A, Pedroni E, Reist H, Timmermann B, Verweij J. The use of protons in cancer therapy at PSI and related instrumentation. ACTA ACUST UNITED AC 2006. [DOI: 10.1088/1742-6596/41/1/005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Abstract
Predictions of the normal-tissue complication probability (NTCP) for the ranking of treatment plans are based on fits of dose-volume models to clinical and/or experimental data. In the literature several different fit methods are used. In this work frequently used methods and techniques to fit NTCP models to dose response data for establishing dose-volume effects, are discussed. The techniques are tested for their usability with dose-volume data and NTCP models. Different methods to estimate the confidence intervals of the model parameters are part of this study. From a critical-volume (CV) model with biologically realistic parameters a primary dataset was generated, serving as the reference for this study and describable by the NTCP model. The CV model was fitted to this dataset. From the resulting parameters and the CV model, 1000 secondary datasets were generated by Monte Carlo simulation. All secondary datasets were fitted to obtain 1000 parameter sets of the CV model. Thus the 'real' spread in fit results due to statistical spreading in the data is obtained and has been compared with estimates of the confidence intervals obtained by different methods applied to the primary dataset. The confidence limits of the parameters of one dataset were estimated using the methods, employing the covariance matrix, the jackknife method and directly from the likelihood landscape. These results were compared with the spread of the parameters, obtained from the secondary parameter sets. For the estimation of confidence intervals on NTCP predictions, three methods were tested. Firstly, propagation of errors using the covariance matrix was used. Secondly, the meaning of the width of a bundle of curves that resulted from parameters that were within the one standard deviation region in the likelihood space was investigated. Thirdly, many parameter sets and their likelihood were used to create a likelihood-weighted probability distribution of the NTCP. It is concluded that for the type of dose response data used here, only a full likelihood analysis will produce reliable results. The often-used approximations, such as the usage of the covariance matrix, produce inconsistent confidence limits on both the parameter sets and the resulting NTCP values.
Collapse
Affiliation(s)
- P van Luijk
- Kernfysisch Versneller Instituut, Groningen, The Netherlands
| | | | | | | |
Collapse
|
15
|
van Luijk P, Bijl HP, Coppes RP, van der Kogel AJ, Konings AW, Pikkemaat JA, Schippers JM. Techniques for precision irradiation of the lateral half of the rat cervical spinal cord using 150 MeV protons [corrected]. Phys Med Biol 2001; 46:2857-71. [PMID: 11720351 DOI: 10.1088/0031-9155/46/11/307] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Techniques for high precision irradiation experiments with protons, to investigate the volume dependence of the tolerance dose of the rat cervical spinal cord are described. In the present study, 50% of the lateral cross section of the spinal cord was irradiated. The diameter of the cross section of this part of the rat spinal cord is at maximum 3.5 mm. Therefore, a dedicated procedure was developed to comply with the needs for a very high positioning accuracy and high spatial resolution dosimetry. By using 150 MeV protons a steep dose gradient (20-80% = 1 mm) in the centre of the spinal cord was achieved. This yields a good dose contrast between the left and right halves of the cord. A home-made digital x-ray imager with a pixel resolution of 0.18 mm/pixel was used for position verification of the spinal cord. A positioning accuracy of 0.09 mm was obtained by using information of multiple pixels. The average position stability during the irradiation was found to be 0.08 mm (1 SD) without significant systematic deviations. Profiles of the dose distribution were measured with a 2D dosimetry system consisting of a scintillating screen and a CCD camera. Dose volume histograms of the whole spinal cord as well as separately of the white and grey matters were calculated using MRI imaging of the cross section of the rat cervical spinal cord. From the irradiation of 20 animals a dose-response curve has been established. MRI showed radiation-induced damage at the high dose side of the spinal cord. Analysis of the preliminary dose-response data shows a significant dose-volume effect. With the described procedure and equipment it is possible to perform high precision irradiations on selected parts of the spinal cord.
Collapse
Affiliation(s)
- P van Luijk
- Kernfysisch Versneller Instituut, Groningen, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
16
|
Abstract
Monte Carlo simulations have been performed to determine the influence of collimator-scattered protons from a 150 MeV proton beam on the dose distribution behind a collimator. Slit-shaped collimators with apertures between 2 and 20 mm have been simulated. The Monte Carlo code GEANT 3.21 has been validated against one-dimensional dose measurements with a scintillating screen, observed by a CCD camera. In order to account for the effects of the spatial response of the CCD/scintillator system, the line-spread function was determined by comparison with measurements made with a diamond detector. The line-spread function of the CCD/scintillator system is described by a Gaussian distribution with a standard deviation of 0.22 mm. The Monte Carlo simulations show that protons that hit the collimator on the entrance face and leave it through the wall of the aperture make the largest scatter contribution. Scatter on air is the major contribution to the extent of the penumbra. From the energy spectra it is derived that protons with a relative biological effectiveness greater than 1 cause at most 1% more damage in tissue than what would be expected from the physical dose.
Collapse
Affiliation(s)
- P van Luijk
- Kernfysisch Versneller Instituut, Groningen, The Netherlands.
| | | | | | | |
Collapse
|
17
|
Boon SN, van Luijk P, Böhringer T, Coray A, Lomax A, Pedroni E, Schaffner B, Schippers JM. Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniques. Med Phys 2000; 27:2198-208. [PMID: 11099186 DOI: 10.1118/1.1289372] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A two-dimensionally position sensitive dosimetry system has been tested for different dosimetric applications in a radiation therapy facility with a scanning proton beam. The system consists of a scintillating (fluorescent) screen, mounted at the beam-exit side of a phantom and it is observed by a charge coupled device (CCD) camera. The observed light distribution at the screen is equivalent to the two-dimensional (2D)-dose distribution at the screen position. It has been found that the dosimetric properties of the system, measured in a scanning proton beam, are equal to those measured in a proton beam broadened by a scattering system. Measurements of the transversal dose distribution of a single pencil beam are consistent with dose measurements as well as with dose calculations in clinically relevant fields made with multiple pencil beams. Measurements of inhomogeneous dose distributions have shown to be of sufficient accuracy to be suitable for the verification of dose calculation algorithms. The good sensitivity and sub-mm spatial resolution of the system allows for the detection of deviations of a few percent in dose from the expected (intended or calculated) dose distribution. Its dosimetric properties and the immediate availability of the data make this device a useful tool in the quality control of scanning proton beams.
Collapse
Affiliation(s)
- S N Boon
- Kernfysisch Versneller Instituut, Groningen, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Barkhof J, Schut G, Flanz JB, Goitein M, Schippers JM. Verification of the alignment of a therapeutic radiation beam relative to its patient positioner. Med Phys 1999; 26:2429-37. [PMID: 10587228 DOI: 10.1118/1.598761] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
An easily-used system has been developed for routine measurements of the alignment of beams used for radiation therapy. The position of a beam of circular cross section is measured with respect to a steel sphere fixed to the patient positioning table and which should coincide with the isocenter. Since measurements can be done at all gantry angles (if one is available) and with all possible orientations of the patient table, the system is particularly suited for rapid and accurate measurements of gantry and/or couch isocentricity. Because it directly measures beam-to-positioner offset, the system provides an inclusive alignment verification of the total treatment system. The system has been developed for use with proton beams, but it could equally be used for alignment checks of an x-ray beam from a linear accelerator or other source. The measuring instrument consists of a scintillation screen viewed by a CCD camera, mounted on the gantry downstream of the sphere. The steel sphere is not large enough to stop protons of all energies of interest; however, it will always modify the energy and direction of protons which intersect it, creating a region of lower intensity (a "shadow") in the light spot created by the proton beam hitting the screen. The position of the shadow with respect to the light spot is a measure of the alignment of the system. An image-analysis algorithm has been developed for an automatic determination of the position of the shadow with respect to the light spot. The specifications and theoretical analysis of the system have been derived from Monte Carlo simulations, which are validated by measurements. We have demonstrated that the device detects beam misalignments with an accuracy (1 s.d.) of 0.05 mm, which is in agreement with the expected performance. This accuracy is more than sufficient to detect the maximum allowed misalignment of +/-0.5 mm.
Collapse
Affiliation(s)
- J Barkhof
- Kernfysisch Versneller Instituut, Groningen, The Netherlands
| | | | | | | | | |
Collapse
|
19
|
Boon SN, van Luijk P, Schippers JM, Meertens H, Denis JM, Vynckier S, Medin J, Grusell E. Fast 2D phantom dosimetry for scanning proton beams. Med Phys 1998; 25:464-75. [PMID: 9571612 DOI: 10.1118/1.598221] [Citation(s) in RCA: 95] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.
Collapse
Affiliation(s)
- S N Boon
- Kernfysisch Versneller Instituut, Groningen, The Netherlands.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Schippers JM, Blasi N, Emery GT, Harakeh MN, Waroquier M. Core polarization and quenching in stretched spin states: Case study of the 9- Ex=3.522 MeV state in 116Sn. Phys Rev C Nucl Phys 1987; 36:1796-1806. [PMID: 9954285 DOI: 10.1103/physrevc.36.1796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|