1
|
Liu X, Domier CW, Dannenberg J, Zhu Y, Sirigiri JR, Ren Y, Stratton B, Luhmann NC. The National Spherical Torus Experiment-Upgrade poloidal high-k scattering system pitch angle design modifications. Rev Sci Instrum 2022; 93:103509. [PMID: 36319363 DOI: 10.1063/5.0099912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Accepted: 08/23/2022] [Indexed: 06/16/2023]
Abstract
A 693 GHz, eight-channel, poloidal high-k (k refers to wavenumber) collective scattering system is under development for the National Spherical Torus Experiment-Upgrade device. It will replace the previous 280 GHz, five-channel, tangential scattering system to study high-k electron density fluctuations, thereby providing a measurement of the kθ-spectrum of both electron temperature gradient and ion temperature gradient modes. A tool is under development to calculate the wavenumber that exists in the presence of strong magnetic pitch angles. We use this tool to motivate a new receiver optical design for significantly improved performance, details of which are presented herein.
Collapse
Affiliation(s)
- X Liu
- University of California at Davis, 1 Shields Ave., Davis, California 95616, USA
| | - C W Domier
- University of California at Davis, 1 Shields Ave., Davis, California 95616, USA
| | - J Dannenberg
- University of California at Davis, 1 Shields Ave., Davis, California 95616, USA
| | - Y Zhu
- University of California at Davis, 1 Shields Ave., Davis, California 95616, USA
| | - J R Sirigiri
- Bridge 12 Technologies, Inc., 37 Loring Drive, Framingham, Massachusetts 01702, USA
| | - Y Ren
- Princeton Plasma Physics Laboratory, 100 Stellarator Rd., Princeton, New Jersey 08540, USA
| | - B Stratton
- Princeton Plasma Physics Laboratory, 100 Stellarator Rd., Princeton, New Jersey 08540, USA
| | - N C Luhmann
- University of California at Davis, 1 Shields Ave., Davis, California 95616, USA
| |
Collapse
|
2
|
Scott FJ, Sesti EL, Choi EJ, Laut AJ, Sirigiri JR, Barnes AB. Magic angle spinning NMR with metallized rotors as cylindrical microwave resonators. Magn Reson Chem 2018; 56:831-835. [PMID: 29672916 DOI: 10.1002/mrc.4744] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 03/22/2018] [Accepted: 04/11/2018] [Indexed: 05/05/2023]
Abstract
We introduce a novel design for millimeter wave electromagnetic structures within magic angle spinning (MAS) rotors. In this demonstration, a copper coating is vacuum deposited onto the outside surface of a sapphire rotor at a thickness of 50 nm. This thickness is sufficient to reflect 197-GHz microwaves, yet not too thick as to interfere with radiofrequency fields at 300 MHz or prevent sample spinning due to eddy currents. Electromagnetic simulations of an idealized rotor geometry show a microwave quality factor of 148. MAS experiments with sample rotation frequencies of ωr /2π = 5.4 kHz demonstrate that the drag force due to eddy currents within the copper does not prevent sample spinning. Spectra of sodium acetate show resolved 13 C J-couplings of 60 Hz and no appreciable broadening between coated and uncoated sapphire rotors, demonstrating that the copper coating does not prevent shimming and high-resolution nuclear magnetic resonance spectroscopy. Additionally, 13 C Rabi nutation curves of ω1 /2π = 103 kHz for both coated and uncoated rotors indicate no detrimental impact of the copper coating on radio frequency coupling of the nuclear spins to the sample coil. We present this metal coated rotor as a first step towards an MAS resonator. MAS resonators are expected to have a significant impact on developments in electron decoupling, pulsed dynamic nuclear polarization (DNP), room temperature DNP, DNP with low-power microwave sources, and electron paramagnetic resonance detection.
Collapse
Affiliation(s)
- Faith J Scott
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO, 63130, USA
| | - Erika L Sesti
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO, 63130, USA
| | - Eric J Choi
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO, 63130, USA
| | - Alexander J Laut
- Bridge 12 Technologies, Inc., 37 Loring Drive, Framingham, MA, 01702, USA
| | | | - Alexander B Barnes
- Department of Chemistry, Washington University in St. Louis, One Brookings Drive, St. Louis, MO, 63130, USA
| |
Collapse
|
3
|
Abstract
We present an alternate simplified concept to irradiate a nuclear magnetic resonance sample with terahertz (THz) radiation for dynamic nuclear polarization (DNP) experiments using the TE(01) circular waveguide mode for transmission of the THz power and the illumination of the DNP sample by either the TE(01) or TE(11) mode. Using finite element method and 3D electromagnetic simulations we demonstrate that the average value of the transverse magnetic field induced by the THz radiation and responsible for the DNP effect using the TE(11) or the TE(01) mode are comparable to that generated by the HE(11) mode and a corrugated waveguide. The choice of the TE(11)/TE(01) mode allows the use of a smooth-walled, oversized waveguide that is easier to fabricate and less expensive than a corrugated waveguide required for transmission of the HE(11) mode. Also, the choice of the TE(01) mode can lead to a simplification of gyrotron oscillators that operate in the TE(0n) mode, by employing an on-axis rippled-wall mode converter to convert the TE(0n) mode into the TE(01) mode either inside or outside of the gyrotron tube. These novel concepts will lead to a significant simplification of the gyrotron, the transmission line and the THz coupler, which are the three main components of a DNP system.
Collapse
Affiliation(s)
- Thorsten Maly
- Bridge12 Technologies, Inc., Framingham, MA 01702, USA, URL: http://www.bridge12.com
| | | |
Collapse
|
4
|
Kim HJ, Nanni EA, Shapiro MA, Sirigiri JR, Woskov PP, Temkin RJ. Amplification of picosecond pulses in a 140-GHz gyrotron-traveling wave tube. Phys Rev Lett 2010; 105:135101. [PMID: 21230783 PMCID: PMC3079330 DOI: 10.1103/physrevlett.105.135101] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Indexed: 05/05/2023]
Abstract
An experimental study of picosecond pulse amplification in a gyrotron-traveling wave tube (gyro-TWT) has been carried out. The gyro-TWT operates with 30 dB of small signal gain near 140 GHz in the HE₀₆ mode of a confocal waveguide. Picosecond pulses show broadening and transit time delay due to two distinct effects: the frequency dependence of the group velocity near cutoff and gain narrowing by the finite gain bandwidth of 1.2 GHz. Experimental results taken over a wide range of parameters show good agreement with a theoretical model in the small signal gain regime. These results show that in order to limit the pulse broadening effect in gyrotron amplifiers, it is crucial to both choose an operating frequency at least several percent above the cutoff of the waveguide circuit and operate at the center of the gain spectrum with sufficient gain bandwidth.
Collapse
Affiliation(s)
- H J Kim
- Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | | | | | | | | | | |
Collapse
|
5
|
Barnes AB, Corzilius B, Mak-Jurkauskas ML, Andreas LB, Bajaj VS, Matsuki Y, Belenky ML, Lugtenburg J, Sirigiri JR, Temkin RJ, Herzfeld J, Griffin RG. Resolution and polarization distribution in cryogenic DNP/MAS experiments. Phys Chem Chem Phys 2010; 12:5861-7. [PMID: 20454732 PMCID: PMC4085575 DOI: 10.1039/c003763j] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This contribution addresses four potential misconceptions associated with high-resolution dynamic nuclear polarization/magic angle spinning (DNP/MAS) experiments. First, spectral resolution is not generally compromised at the cryogenic temperatures at which DNP experiments are performed. As we demonstrate at a modest field of 9 T (380 MHz (1)H), 1 ppm linewidths are observed in DNP/MAS spectra of a membrane protein in its native lipid bilayer, and <0.4 ppm linewidths are reported in a crystalline peptide at 85 K. Second, we address the concerns about paramagnetic broadening in DNP/MAS spectra of proteins by demonstrating that the exogenous radical polarizing agents utilized for DNP are distributed in the sample in such a manner as to avoid paramagnetic broadening and thus maintain full spectral resolution. Third, the enhanced polarization is not localized around the polarizing agent, but rather is effectively and uniformly dispersed throughout the sample, even in the case of membrane proteins. Fourth, the distribution of polarization from the electron spins mediated via spin diffusion between (1)H-(1)H strongly dipolar coupled spins is so rapid that shorter magnetization recovery periods between signal averaging transients can be utilized in DNP/MAS experiments than in typical experiments performed at ambient temperature.
Collapse
Affiliation(s)
- Alexander B. Barnes
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Björn Corzilius
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Melody L. Mak-Jurkauskas
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Loren B. Andreas
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Vikram S. Bajaj
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Yoh Matsuki
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Marina L. Belenky
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | | | - Jagadishwar R. Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Richard J. Temkin
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Judith Herzfeld
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Robert G. Griffin
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
6
|
Torrezan AC, Han ST, Mastovsky I, Shapiro MA, Sirigiri JR, Temkin RJ, Griffin RG, Barnes AB. Continuous-Wave Operation of a Frequency-Tunable 460-GHz Second-Harmonic Gyrotron for Enhanced Nuclear Magnetic Resonance. IEEE Trans Electron Devices 2010; 38:1150-1159. [PMID: 23761938 PMCID: PMC3677787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The design, operation, and characterization of a continuous-wave (CW) tunable second-harmonic 460-GHz gyrotron are reported. The gyrotron is intended to be used as a submillimeter-wave source for 700-MHz nuclear magnetic resonance experiments with sensitivity enhanced by dynamic nuclear polarization. The gyrotron operates in the whispering-gallery mode TE11,2 and has generated 16 W of output power with a 13-kV 100-mA electron beam. The start oscillation current measured over a range of magnetic field values is in good agreement with theoretical start currents obtained from linear theory for successive high-order axial modes TE11,2,q. The minimum start current is 27 mA. Power and frequency tuning measurements as a function of the electron cyclotron frequency have also been carried out. A smooth frequency tuning range of 1 GHz was obtained for the operating second-harmonic mode either by magnetic field tuning or beam voltage tuning. Long-term CW operation was evaluated during an uninterrupted period of 48 h, where the gyrotron output power and frequency were kept stable to within ±0.7% and ±6 ppm, respectively, by a computerized control system. Proper operation of an internal quasi-optical mode converter implemented to transform the operating whispering-gallery mode to a Gaussian-like beam was also verified. Based on the images of the gyrotron output beam taken with a pyroelectric camera, the Gaussian-like mode content of the output beam was computed to be 92% with an ellipticity of 12%.
Collapse
Affiliation(s)
- Antonio C Torrezan
- Department of Electrical Engineering and Computer Science and the Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA ( )
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Torrezan AC, Han ST, Mastovsky I, Shapiro MA, Sirigiri JR, Temkin RJ, Barnes AB, Griffin RG. Continuous-Wave Operation of a Frequency-Tunable 460-GHz Second-Harmonic Gyrotron for Enhanced Nuclear Magnetic Resonance. IEEE Trans Plasma Sci IEEE Nucl Plasma Sci Soc 2010; 38:1150-1160. [PMID: 21243088 PMCID: PMC3021140 DOI: 10.1109/tps.2010.2046617] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The design, operation, and characterization of a continuous-wave (CW) tunable second-harmonic 460-GHz gyrotron are reported. The gyrotron is intended to be used as a submillimeter-wave source for 700-MHz nuclear magnetic resonance experiments with sensitivity enhanced by dynamic nuclear polarization. The gyrotron operates in the whispering-gallery mode TE(11,2) and has generated 16 W of output power with a 13-kV 100-mA electron beam. The start oscillation current measured over a range of magnetic field values is in good agreement with theoretical start currents obtained from linear theory for successive high-order axial modes TE(11,2,q). The minimum start current is 27 mA. Power and frequency tuning measurements as a function of the electron cyclotron frequency have also been carried out. A smooth frequency tuning range of 1 GHz was obtained for the operating second-harmonic mode either by magnetic field tuning or beam voltage tuning. Long-term CW operation was evaluated during an uninterrupted period of 48 h, where the gyrotron output power and frequency were kept stable to within ±0.7% and ±6 ppm, respectively, by a computerized control system. Proper operation of an internal quasi-optical mode converter implemented to transform the operating whispering-gallery mode to a Gaussian-like beam was also verified. Based on the images of the gyrotron output beam taken with a pyroelectric camera, the Gaussian-like mode content of the output beam was computed to be 92% with an ellipticity of 12%.
Collapse
Affiliation(s)
- Antonio C. Torrezan
- Department of Electrical Engineering and Computer Science and the Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Seong-Tae Han
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA. He is now with the Korea Electrotechnology Research Institute, Ansan 426-170, Korea
| | - Ivan Mastovsky
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Michael A. Shapiro
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Jagadishwar R. Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Richard J. Temkin
- Department of Physics and the Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Alexander B. Barnes
- Department of Chemistry and the Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Robert G. Griffin
- Department of Chemistry and the Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| |
Collapse
|
8
|
Barnes AB, Mak-Jurkauskas ML, Matsuki Y, Bajaj VS, van der Wel PCA, DeRocher R, Bryant J, Sirigiri JR, Temkin RJ, Lugtenburg J, Herzfeld J, Griffin RG. Cryogenic sample exchange NMR probe for magic angle spinning dynamic nuclear polarization. J Magn Reson 2009; 198:261-70. [PMID: 19356957 PMCID: PMC2957365 DOI: 10.1016/j.jmr.2009.03.003] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2009] [Accepted: 03/11/2009] [Indexed: 05/05/2023]
Abstract
We describe a cryogenic sample exchange system that dramatically improves the efficiency of magic angle spinning (MAS) dynamic nuclear polarization (DNP) experiments by reducing the time required to change samples and by improving long-term instrument stability. Changing samples in conventional cryogenic MAS DNP/NMR experiments involves warming the probe to room temperature, detaching all cryogenic, RF, and microwave connections, removing the probe from the magnet, replacing the sample, and reversing all the previous steps, with the entire cycle requiring a few hours. The sample exchange system described here-which relies on an eject pipe attached to the front of the MAS stator and a vacuum jacketed dewar with a bellowed hole-circumvents these procedures. To demonstrate the excellent sensitivity, resolution, and stability achieved with this quadruple resonance sample exchange probe, we have performed high precision distance measurements on the active site of the membrane protein bacteriorhodopsin. We also include a spectrum of the tripeptide N-f-MLF-OH at 100K which shows 30 Hz linewidths.
Collapse
Affiliation(s)
- Alexander B. Barnes
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Melody L. Mak-Jurkauskas
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Yoh Matsuki
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Vikram S. Bajaj
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Patrick C. A. van der Wel
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ronald DeRocher
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jeffrey Bryant
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jagadishwar R. Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Richard J. Temkin
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Johan Lugtenburg
- Department of Chemistry, Rijksuniversiteit te Leiden, NL-2300 R A Leiden, The Netherlands
| | - Judith Herzfeld
- Department of Chemistry, Brandeis University, Waltham, MA 02454, USA
| | - Robert G. Griffin
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Corresponding author. Fax: 1-617-253-5405, E-mail address:
| |
Collapse
|
9
|
Abstract
The theory, design, and experimental results of a wideband 140-GHz 1-kW pulsed gyro-traveling-wave amplifier (gyro-TWA) are presented. The gyro-TWA operates in the HE(06) mode of an overmoded quasi-optical waveguide using a gyrating electron beam. The electromagnetic theory, interaction theory, design processes, and experimental procedures are described in detail. At 37.7 kV and a 2.7-A beam current, the experiment has produced over 820 W of peak power with a -3-dB bandwidth of 0.8 GHz and a linear gain of 34 dB at 34.7 kV. In addition, the amplifier produced a -3-dB bandwidth of over 1.5 GHz (1.1%) with a peak power of 570 W from a 38.5-kV 2.5-A electron beam. The electron beam is estimated to have a pitch factor of 0.55-0.6, a radius of 1.9 mm, and a calculated perpendicular momentum spread of approximately 9%. The gyro-amplifier was nominally operated at a pulselength of 2 μs but was tested to amplify pulses as short as 4 ns with no noticeable pulse broadening. Internal reflections in the amplifier were identified using these short pulses by time-domain reflectometry. The demonstrated performance of this amplifier shows that it can be applied to dynamic nuclear polarization and electron paramagnetic resonance spectroscopy.
Collapse
Affiliation(s)
- Colin D Joye
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | | | | | | |
Collapse
|
10
|
Han ST, Comfoltey EN, Shapiro MA, Sirigiri JR, Tax DS, Temkin RJ, Woskov PP, Rasmussen DA. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications. Int J Infrared Millimeter Waves 2008; 29:1011-1018. [PMID: 19081774 DOI: 10.1007/s10762-008-9404-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.
Collapse
Affiliation(s)
- S T Han
- Plasma Science and Fusion Center, MIT, Cambridge, MA 02139-4294, USA; Korea Electrotechnology Research Institute, Changwon, Kyungnam 641-120, Republic of Korea
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Barnes AB, Paëpe GD, van der Wel PCA, Hu KN, Joo CG, Bajaj VS, Mak-Jurkauskas ML, Sirigiri JR, Herzfeld J, Temkin RJ, Griffin RG. High-Field Dynamic Nuclear Polarization for Solid and Solution Biological NMR. Appl Magn Reson 2008; 34:237-263. [PMID: 19194532 PMCID: PMC2634864 DOI: 10.1007/s00723-008-0129-1] [Citation(s) in RCA: 222] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Dynamic nuclear polarization (DNP) results in a substantial nuclear polarization enhancement through a transfer of the magnetization from electrons to nuclei. Recent years have seen considerable progress in the development of DNP experiments directed towards enhancing sensitivity in biological nuclear magnetic resonance (NMR). This review covers the applications, hardware, polarizing agents, and theoretical descriptions that were developed at the Francis Bitter Magnet Laboratory at Massachusetts Institute of Technology for high-field DNP experiments. In frozen dielectrics, the enhanced nuclear polarization developed in the vicinity of the polarizing agent can be efficiently dispersed to the bulk of the sample via (1)H spin diffusion. This strategy has been proven effective in polarizing biologically interesting systems, such as nanocrystalline peptides and membrane proteins, without leading to paramagnetic broadening of the NMR signals. Gyrotrons have been used as a source of high-power (5-10 W) microwaves up to 460 GHz as required for the DNP experiments. Other hardware has also been developed allowing in situ microwave irradiation integrated with cryogenic magic-angle-spinning solid-state NMR. Advances in the quantum mechanical treatment are successful in describing the mechanism by which new biradical polarizing agents yield larger enhancements at higher magnetic fields. Finally, pulsed methods and solution experiments should play a prominent role in the future of DNP.
Collapse
Affiliation(s)
- A B Barnes
- Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Maly T, Debelouchina GT, Bajaj VS, Hu KN, Joo CG, Mak–Jurkauskas ML, Sirigiri JR, van der Wel PCA, Herzfeld J, Temkin RJ, Griffin RG. Dynamic nuclear polarization at high magnetic fields. J Chem Phys 2008; 128:052211. [PMID: 18266416 PMCID: PMC2770872 DOI: 10.1063/1.2833582] [Citation(s) in RCA: 534] [Impact Index Per Article: 33.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Dynamic nuclear polarization (DNP) is a method that permits NMR signal intensities of solids and liquids to be enhanced significantly, and is therefore potentially an important tool in structural and mechanistic studies of biologically relevant molecules. During a DNP experiment, the large polarization of an exogeneous or endogeneous unpaired electron is transferred to the nuclei of interest (I) by microwave (microw) irradiation of the sample. The maximum theoretical enhancement achievable is given by the gyromagnetic ratios (gamma(e)gamma(l)), being approximately 660 for protons. In the early 1950s, the DNP phenomenon was demonstrated experimentally, and intensively investigated in the following four decades, primarily at low magnetic fields. This review focuses on recent developments in the field of DNP with a special emphasis on work done at high magnetic fields (> or =5 T), the regime where contemporary NMR experiments are performed. After a brief historical survey, we present a review of the classical continuous wave (cw) DNP mechanisms-the Overhauser effect, the solid effect, the cross effect, and thermal mixing. A special section is devoted to the theory of coherent polarization transfer mechanisms, since they are potentially more efficient at high fields than classical polarization schemes. The implementation of DNP at high magnetic fields has required the development and improvement of new and existing instrumentation. Therefore, we also review some recent developments in microw and probe technology, followed by an overview of DNP applications in biological solids and liquids. Finally, we outline some possible areas for future developments.
Collapse
Affiliation(s)
- Thorsten Maly
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Galia T. Debelouchina
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Vikram S. Bajaj
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Kan-Nian Hu
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Chan-Gyu Joo
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | | | - Jagadishwar R. Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Patrick C. A. van der Wel
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Judith Herzfeld
- Department of Chemistry, Brandels University, Waltham, Massachusetts 02454, USA
| | - Richard J. Temkin
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Robert G. Griffin
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
13
|
Hidaka Y, Choi EM, Mastovsky I, Shapiro MA, Sirigiri JR, Temkin RJ. Observation of large arrays of plasma filaments in air breakdown by 1.5-MW 110-GHz gyrotron pulses. Phys Rev Lett 2008; 100:035003. [PMID: 18232990 DOI: 10.1103/physrevlett.100.035003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2007] [Indexed: 05/25/2023]
Abstract
We report the observation of two-dimensional plasma filamentary arrays with more than 100 elements generated during breakdown of air at atmospheric pressure by a focused Gaussian beam from a 1.5-MW, 110-GHz gyrotron operating in 3-micros pulses. Each element is a plasma filament elongated in the electric field direction and regularly spaced about one-quarter wavelength apart in the plane perpendicular to the electric field. The development of the array is explained as a result of diffraction of the beam around the filaments, leading to the sequential generation of high intensity spots, at which new filaments are created, about a quarter wavelength upstream from each existing filament. Electromagnetic wave simulations corroborate this explanation and show very good correlation to the observed pattern of filaments.
Collapse
Affiliation(s)
- Yoshiteru Hidaka
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, 167 Albany Street, Cambridge, MA 02139, USA
| | | | | | | | | | | |
Collapse
|
14
|
Bajaj VS, Hornstein MK, Kreischer KE, Sirigiri JR, Woskov PP, Mak-Jurkauskas ML, Herzfeld J, Temkin RJ, Griffin RG. 250GHz CW gyrotron oscillator for dynamic nuclear polarization in biological solid state NMR. J Magn Reson 2007; 189:251-79. [PMID: 17942352 PMCID: PMC2695453 DOI: 10.1016/j.jmr.2007.09.013] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2007] [Revised: 09/03/2007] [Accepted: 09/13/2007] [Indexed: 05/05/2023]
Abstract
In this paper, we describe a 250 GHz gyrotron oscillator, a critical component of an integrated system for magic angle spinning (MAS) dynamic nuclear polarization (DNP) experiments at 9T, corresponding to 380 MHz (1)H frequency. The 250 GHz gyrotron is the first gyro-device designed with the goal of seamless integration with an NMR spectrometer for routine DNP enhanced NMR spectroscopy and has operated under computer control for periods of up to 21 days with a 100% duty cycle. Following a brief historical review of the field, we present studies of the membrane protein bacteriorhodopsin (bR) using DNP enhanced multidimensional NMR. These results include assignment of active site resonances in [U-(13)C, (15)N]-bR and demonstrate the utility of DNP for studies of membrane proteins. Next, we review the theory of gyro-devices from quantum mechanical and classical viewpoints and discuss the unique considerations that apply to gyrotron oscillators designed for DNP experiments. We then characterize the operation of the 250 GHz gyrotron in detail, including its long-term stability and controllability. We have measured the spectral purity of the gyrotron emission using both homodyne and heterodyne techniques. Radiation intensity patterns from the corrugated waveguide that delivers power to the NMR probe were measured using two new techniques to confirm pure mode content: a thermometric approach based on the temperature-dependent color of liquid crystalline media applied to a substrate and imaging with a pyroelectric camera. We next present a detailed study of the mode excitation characteristics of the gyrotron. Exploration of the operating characteristics of several fundamental modes reveals broadband continuous frequency tuning of up to 1.8 GHz as a function of the magnetic field alone, a feature that may be exploited in future tunable gyrotron designs. Oscillation of the 250 GHz gyrotron at the second harmonic of cyclotron resonance begins at extremely low beam currents (as low 12 mA) at frequencies between 320 and 365 GHz, suggesting an efficient route for the generation of even higher frequency radiation. The low starting currents were attributed to an elevated cavity Q, which is confirmed by cavity thermal load measurements. We conclude with an appendix containing a detailed description of the control system that safely automates all aspects of the gyrotron operation.
Collapse
Affiliation(s)
- Vikram S. Bajaj
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139
| | - Melissa K. Hornstein
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Kenneth E. Kreischer
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Jagadishwar R. Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Paul P. Woskov
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | | | - Judith Herzfeld
- Department of Chemistry, Brandeis University, Waltham, MA, 02454
| | - Richard J. Temkin
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA
| | - Robert G. Griffin
- Department of Chemistry and Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA, 02139
| |
Collapse
|
15
|
Han ST, Griffin RG, Hu KN, Joo CG, Joye CD, Sirigiri JR, Temkin RJ, Torrezan AC, Woskov PP. Spectral Characteristics of a 140-GHz Long-Pulsed Gyrotron. IEEE Trans Plasma Sci IEEE Nucl Plasma Sci Soc 2007; 35:559-564. [PMID: 19081779 PMCID: PMC2600513 DOI: 10.1109/tps.2007.896931] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Gyrotrons operating in the millimeter and submillimeter wavelength ranges are the promising sources for applications that are requiring good spectral characteristics and a wide range of output power. We report the precise measurement results of gyrotron spectra. Experiments were conducted using a 140-GHz long-pulse gyrotron that is developed for the dynamic nuclear polarization/nuclear-magnetic-resonance spectroscopy at the Massachusetts Institute of Technology. Transient downshift of the frequency by 12 MHz with a time constant of 3 s was observed. After reaching equilibrium, the frequency was maintained within 1 ppm for over 20 s. The coefficient of the frequency change with cavity temperature was -2.0 MHz/K, which shows that fine tuning of the gyrotron frequency is plausible by cavity-temperature control. Frequency pulling by the beam current was observed, but it was shown to be masked by the downward shift of the gyrotron frequency with temperature. The linewidth was measured to be much less than 1 MHz at 60 dB relative to the carrier power [in decibels relative to carrier (dBc)] and 4.3 MHz at 75 dBc, which is the largest dynamic range to date for the measurement of gyrotron linewidth to our knowledge.
Collapse
Affiliation(s)
- Seong-Tae Han
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139-4294 USA
| | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Shapiro MA, Shvets G, Sirigiri JR, Temkin RJ. Spatial dispersion in metamaterials with negative dielectric permittivity and its effect on surface waves. Opt Lett 2006; 31:2051-3. [PMID: 16770429 DOI: 10.1364/ol.31.002051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The effect of spatial dispersion on the electromagnetic properties of a metamaterial consisting of a three-dimensional mesh of crossing metallic wires is reported. The effective dielectric permittivity tensor epsilon(ij)(omega, k) of the wire mesh is calculated in the limit of small wavenumbers. The procedure for extracting the spatial dispersion from the omega versus k dependence for electromagnetic waves propagating in the bulk of the metamaterial is developed. These propagating modes are identified as similar to the longitudinal (plasmon) and transverse (photon) waves in a plasma. Spatial dispersion is found to have the most dramatic effect on the surface waves that exist at the wire mesh-vacuum interface.
Collapse
Affiliation(s)
- M A Shapiro
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
| | | | | | | |
Collapse
|
17
|
Joye CD, Griffin RG, Hornstein MK, Hu KN, Kreischer KE, Rosay M, Shapiro MA, Sirigiri JR, Temkin RJ, Woskov PP. Operational Characteristics of a 14-W 140-GHz Gyrotron for Dynamic Nuclear Polarization. IEEE Trans Plasma Sci IEEE Nucl Plasma Sci Soc 2006; 34:518-523. [PMID: 17431442 PMCID: PMC1851936 DOI: 10.1109/tps.2006.875776] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The operating characteristics of a 140-GHz 14-W long pulse gyrotron are presented. The device is being used in dynamic nuclear polarization enhanced nuclear magnetic resonance (DNP/NMR) spectroscopy experiments. The gyrotron yields 14 W peak power at 139.65 GHz from the TE(0,3) operating mode using a 12.3-kV 25-mA electron beam. Additionally, up to 12 W peak has been observed in the TE(2,3) mode at 136.90 GHz. A series of mode converters transform the TE(0,3) operating mode to the TE(1,1) mode. Experimental results are compared with nonlinear simulations and show reasonable agreement. The millimeter-wave output beam was imaged in a single shot using a pyroelectric camera. The mode patterns matched reasonably well to theory for both the TE(0,1) mode and the TE(1,1) mode. Repeatable mode patterns were obtained at intervals ranging from 0.8 s apart to 11 min apart at the output of the final mode converter.
Collapse
Affiliation(s)
- Colin D Joye
- Student Member, IEEE, The Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 USA (e-mail: )
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Han ST, Griffin RG, Hu KN, Joo CG, Joye CD, Mastovsky I, Shapiro MA, Sirigiri JR, Temkin RJ, Torrezan AC, Woskov PP. Continuous-wave Submillimeter-wave Gyrotrons. Proc SPIE Int Soc Opt Eng 2006; 6373:63730C. [PMID: 17404605 PMCID: PMC1847421 DOI: 10.1117/12.686436] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Recently, dynamic nuclear polarization enhanced nuclear magnetic resonance (DNP/NMR) has emerged as a powerful technique to obtain significant enhancements in spin spectra from biological samples. For DNP in modern NMR systems, a high power continuous-wave source in the submillimeter wavelength range is necessary. Gyrotrons can deliver tens of watts of CW power at submillimeter wavelengths and are well suited for use in DNP/NMR spectrometers. To date, 140 GHz and 250 GHz gyrotrons are being employed in DNP spectrometer experiments at 200 MHz and 380 MHz at MIT. A 460 GHz gyrotron, which has operated with 8 W of CW output power, will soon be installed in a 700 MHz NMR spectrometer. High power radiation with good spectral and spatial resolution from these gyrotrons should provide NMR spectrometers with high signal enhancement through DNP. Also, these tubes operating at submillimeter wavelengths should have important applications in research in physics, chemistry, biology, materials science and medicine.
Collapse
Affiliation(s)
- Seong-Tae Han
- Plasma Science and Fusion Center, MIT, Cambridge, MA, USA 02139-4294
| | | | - Kan-Nian Hu
- Francis Bitter Magnet Laboratory, MIT, Cambridge, MA 02139-4294
| | - Chan-Gyu Joo
- Francis Bitter Magnet Laboratory, MIT, Cambridge, MA 02139-4294
| | - Colin D. Joye
- Plasma Science and Fusion Center, MIT, Cambridge, MA, USA 02139-4294
| | - Ivan Mastovsky
- Plasma Science and Fusion Center, MIT, Cambridge, MA, USA 02139-4294
| | | | | | - Richard J. Temkin
- Plasma Science and Fusion Center, MIT, Cambridge, MA, USA 02139-4294
| | | | - Paul P. Woskov
- Plasma Science and Fusion Center, MIT, Cambridge, MA, USA 02139-4294
| |
Collapse
|
19
|
Korbly SE, Kesar AS, Sirigiri JR, Temkin RJ. Observation of frequency-locked coherent terahertz Smith-Purcell radiation. Phys Rev Lett 2005; 94:054803. [PMID: 15783652 DOI: 10.1103/physrevlett.94.054803] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2004] [Indexed: 05/24/2023]
Abstract
We report the observation of enhanced coherent Smith-Purcell radiation (SPR) at terahertz (THz) frequencies from a train of picosecond bunches of 15 MeV electrons passing above a grating. SPR is more intense than other sources, such as transition radiation, by a factor of Ng, the number of grating periods. For electron bunches that are short compared with the radiation wavelength, coherent emission occurs, enhanced by a factor of Ne, the number of electrons in the bunch. The electron beam consists of a train of Nb bunches, giving an energy density spectrum restricted to harmonics of the 17 GHz bunch train frequency, with an increased energy density at these frequencies by a factor of Nb. We report the first observation of SPR displaying all three of these enhancements, NgNeNb. This powerful SPR THz radiation can be detected with a high signal to noise ratio by a heterodyne receiver.
Collapse
Affiliation(s)
- S E Korbly
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, 167 Albany Street, Cambridge, Massachusetts 02139, USA
| | | | | | | |
Collapse
|
20
|
Sirigiri JR, Shapiro MA, Temkin RJ. High-power 140-GHz quasioptical gyrotron traveling-wave amplifier. Phys Rev Lett 2003; 90:258302. [PMID: 12857176 DOI: 10.1103/physrevlett.90.258302] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2003] [Indexed: 05/24/2023]
Abstract
We present the design and experimental results of a novel quasioptical gyrotron traveling-wave tube (gyro-TWT) amplifier at 140 GHz. The gyro-TWT produced up to 30 kW of peak power in 2 micros pulsed operation at 6 Hz achieving a peak gain of 29 dB, a peak efficiency of 12%, and a bandwidth of 2.3 GHz. The device was operated in a very higher-order mode of an open quasioptical interaction structure, namely, a confocal waveguide. The diffraction loss from the open sidewalls of the confocal waveguide was used to suppress mode competition in this highly overmoded circuit resulting in a stable single-mode operation. The experiment achieved record high power levels at 140 GHz for a gyro-TWT. These experiments demonstrate the effectiveness of using overmoded quasioptical waveguide interaction structures for generating high power in the millimeter and submillimeter wave bands with a gyro-TWT.
Collapse
Affiliation(s)
- J R Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, 167 Albany Street, Cambridge, Massachusetts 02139, USA
| | | | | |
Collapse
|
21
|
Sirigiri JR, Kreischer KE, Machuzak J, Mastovsky I, Shapiro MA, Temkin RJ. Photonic-band-gap resonator gyrotron. Phys Rev Lett 2001; 86:5628-5631. [PMID: 11415318 DOI: 10.1103/physrevlett.86.5628] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2001] [Indexed: 05/23/2023]
Abstract
We report the design and experimental demonstration of a gyrotron oscillator using a photonic-band-gap (PBG) structure to eliminate mode competition in a highly overmoded resonator. The PBG cavity supports a TE(041)-like mode at 140 GHz and is designed to have no competing modes over a minimum frequency range delta omega/omega of 30% about the design mode. Experimental operation of a PBG gyrotron at 68 kV and 5 A produced 25 kW of peak power in the design mode. No other modes were observed over the full predicted operating range about the design mode. PBG cavities show great promise for applications in vacuum electron devices in the millimeter- and submillimeter-wave bands.
Collapse
Affiliation(s)
- J R Sirigiri
- Plasma Science and Fusion Center, Massachusetts Institute of Technology, 167 Albany Street, Cambridge, Massachusetts 02139, USA.
| | | | | | | | | | | |
Collapse
|