1
|
Qin H, Fietze I, Mazzotti DR, Steenbergen N, Kraemer JF, Glos M, Wessel N, Song L, Penzel T, Zhang X. Obstructive sleep apnea heterogeneity and autonomic function: a role for heart rate variability in therapy selection and efficacy monitoring. J Sleep Res 2024; 33:e14020. [PMID: 37709966 DOI: 10.1111/jsr.14020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 07/23/2023] [Accepted: 08/03/2023] [Indexed: 09/16/2023]
Abstract
Obstructive sleep apnea is a highly prevalent sleep-related breathing disorder, resulting in a disturbed breathing pattern, changes in blood gases, abnormal autonomic regulation, metabolic fluctuation, poor neurocognitive performance, and increased cardiovascular risk. With broad inter-individual differences recognised in risk factors, clinical symptoms, gene expression, physiological characteristics, and health outcomes, various obstructive sleep apnea subtypes have been identified. Therapeutic efficacy and its impact on outcomes, particularly for cardiovascular consequences, may also vary depending on these features in obstructive sleep apnea. A number of interventions such as positive airway pressure therapies, oral appliance, surgical treatment, and pharmaceutical options are available in clinical practice. Selecting an effective obstructive sleep apnea treatment and therapy is a challenging medical decision due to obstructive sleep apnea heterogeneity and numerous treatment modalities. Thus, an objective marker for clinical evaluation is warranted to estimate the treatment response in patients with obstructive sleep apnea. Currently, while the Apnea-Hypopnea Index is used for severity assessment of obstructive sleep apnea and still considered a major guide to diagnosis and managements of obstructive sleep apnea, the Apnea-Hypopnea Index is not a robust marker of symptoms, function, or outcome improvement. Abnormal cardiac autonomic modulation can provide additional insight to better understand obstructive sleep apnea phenotyping. Heart rate variability is a reliable neurocardiac tool to assess altered autonomic function and can also provide cardiovascular information in obstructive sleep apnea. Beyond the Apnea-Hypopnea Index, this review aims to discuss the role of heart rate variability as an indicator and predictor of therapeutic efficacy to different modalities in order to optimise tailored treatment for obstructive sleep apnea.
Collapse
Affiliation(s)
- Hua Qin
- Department of Otolaryngology, Head and Neck Surgery, State Key Laboratory of Respiratory Disease, The Key Laboratory of Advanced Interdisciplinary Studies Center, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Ingo Fietze
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
- The Fourth People's Hospital of Guangyuan, Guangyuan, China
| | - Diego R Mazzotti
- Division of Medical Informatics, Department of Internal Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
- Division of Pulmonary Critical Care and Sleep Medicine, Department of Internal Medicine, University of Kansas Medical Center, Kansas City, Kansas, USA
| | | | - Jan F Kraemer
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
- Information Processing and Analytics Group, School of Library and Information Science, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Martin Glos
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Niels Wessel
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
- Department of Medicine, Medical School Berlin, Berlin, Germany
| | - Lijun Song
- Department of Otolaryngology, Head and Neck Surgery, State Key Laboratory of Respiratory Disease, The Key Laboratory of Advanced Interdisciplinary Studies Center, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| | - Thomas Penzel
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Xiaowen Zhang
- Department of Otolaryngology, Head and Neck Surgery, State Key Laboratory of Respiratory Disease, The Key Laboratory of Advanced Interdisciplinary Studies Center, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China
| |
Collapse
|
2
|
Wang Y, Huang Y, Xia M, Salanitro M, Kraemer JF, Toncar T, Fietze I, Schöbel C, Penzel T. Effect of phrenic nerve stimulation on patients with central sleep apnea: A meta-analysis. Sleep Med Rev 2023; 70:101819. [PMID: 37467524 DOI: 10.1016/j.smrv.2023.101819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 07/08/2023] [Accepted: 07/10/2023] [Indexed: 07/21/2023]
Abstract
Patients with central sleep apnea (CSA) have a lower quality of life and higher morbidity and mortality. Phrenic nerve stimulation (PNS) is a novel treatment for CSA that has been shown to be safe. However, the effects of PNS on sleep changes are still under debate. This meta-analysis was performed to evaluate the efficacy of PNS in patients with CSA. PubMed, Scopus, EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL) and Web of Science databases were searched for relevant studies published. We performed random-effects meta-analyses of the changes in apnea-hypopnea index (AHI), central apnea index (CAI), Arousal Index, percent of sleep with O2 saturation <90% (T90), Epworth Sleepiness Scale (ESS) and sleep efficiency. Ten studies with a total of 580 subjects were analyzed. Overall meta-analysis showed AHI [SMD: -2.24, 95% confidence interval (CI): was -3.11 to -1.36(p<0.00001)], CAI [SMD: -2.32, 95% CI: -3.17 to -1.47 (p<0.00001)] and Arousal Index (p = 0.0002, SMD (95% CI) -1.79 (-2.74 to -0.85)) significantly reduced after PNS. No significant changes were observed in T90, ESS and sleep efficiency (p > 0.05). Meta-analysis of observational studies demonstrated AHI, CAI and Arousal Index had a decreasing trend between before and after PNS (all, p<0.05). However, ESS and T90 did not change significantly after PNS (p > 0.05). Meta-analysis of RCTs showed that CSA patients had trends of a lower AHI (I2 = 0%), CAI (I2 = 74%), Arousal Index (I2 = 0%), T90 (I2 = 0%) and ESS (I2 = 0%) after PNS (all, p<0.05). The use of PNS appears to be safe and feasible in patients with CSA. However, larger, independent RCTs are required to investigate the efficacy and long-term effect of PNS and more attention should be paid to T90 and ESS.
Collapse
Affiliation(s)
- Youmeng Wang
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany.
| | - Ying Huang
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany
| | - Mengdi Xia
- Department of Nephrology, The Second Clinical Medical Institution of North Sichuan Medical College (Nanchong Central Hospital) and Nanchong Key Laboratory of Basic Science & Clinical Research on Chronic Kidney Disease, Nanchong, 637000, Sichuan Province, China.
| | - Matthew Salanitro
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany
| | - Jan F Kraemer
- Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany
| | - Theresa Toncar
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany
| | - Ingo Fietze
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany
| | - Christoph Schöbel
- Universitätsmedizin Essen, Ruhrlandklinik - Westdeutsches Lungenzentrum, am Universitätsklinikum Essen GmbH, Tüschener Weg 40, 45239, Essen, Germany
| | - Thomas Penzel
- Sleep Medicine Center, Charité-Universitätsmedizin, Charitéplatz 1, 10117, Berlin, Germany
| |
Collapse
|
3
|
Vaquerizo-Villar F, Alvarez D, Kraemer JF, Wessel N, Gutierrez-Tobal GC, Calvo E, Del Campo F, Kheirandish-Gozal L, Gozal D, Penzel T, Hornero R. Automatic Sleep Staging in Children with Sleep Apnea using Photoplethysmography and Convolutional Neural Networks. Annu Int Conf IEEE Eng Med Biol Soc 2021; 2021:216-219. [PMID: 34891275 DOI: 10.1109/embc46164.2021.9629995] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Sleep staging is of paramount importance in children with suspicion of pediatric obstructive sleep apnea (OSA). Complexity, cost, and intrusiveness of overnight polysomnography (PSG), the gold standard, have led to the search for alternative tests. In this sense, the photoplethysmography signal (PPG) carries useful information about the autonomous nervous activity associated to sleep stages and can be easily acquired in pediatric sleep apnea home tests with a pulse oximeter. In this study, we use the PPG signal along with convolutional neural networks (CNN), a deep-learning technique, for the automatic identification of the three main levels of sleep: wake (W), rapid eye movement (REM), and non-REM sleep. A database of 366 PPG recordings from pediatric OSA patients is involved in the study. A CNN architecture was trained using 30-s epochs from the PPG signal for three-stage sleep classification. This model showed a promising diagnostic performance in an independent test set, with 78.2% accuracy and 0.57 Cohen's kappa for W/NREM/REM classification. Furthermore, the percentage of time in wake stage obtained for each subject showed no statistically significant differences with the manually scored from PSG. These results were superior to the only state-of-the-art study focused on the analysis of the PPG signal in the automated detection of sleep stages in children suffering from OSA. This suggests that CNN can be used along with PPG recordings for sleep stages scoring in pediatric home sleep apnea tests.
Collapse
|
4
|
Qin H, Keenan BT, Mazzotti DR, Vaquerizo-Villar F, Kraemer JF, Wessel N, Tufik S, Bittencourt L, Cistulli PA, de Chazal P, Sutherland K, Singh B, Pack AI, Chen NH, Fietze I, Gislason T, Holfinger S, Magalang UJ, Penzel T. Heart rate variability during wakefulness as a marker of obstructive sleep apnea severity. Sleep 2021; 44:6121869. [PMID: 33506267 DOI: 10.1093/sleep/zsab018] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 01/15/2021] [Indexed: 12/18/2022] Open
Abstract
STUDY OBJECTIVES Patients with obstructive sleep apnea (OSA) exhibit heterogeneous heart rate variability (HRV) during wakefulness and sleep. We investigated the influence of OSA severity on HRV parameters during wakefulness in a large international clinical sample. METHODS 1247 subjects (426 without OSA and 821 patients with OSA) were enrolled from the Sleep Apnea Global Interdisciplinary Consortium. HRV parameters were calculated during a 5-minute wakefulness period with spontaneous breathing prior to the sleep study, using time-domain, frequency-domain and nonlinear methods. Differences in HRV were evaluated among groups using analysis of covariance, controlling for relevant covariates. RESULTS Patients with OSA showed significantly lower time-domain variations and less complexity of heartbeats compared to individuals without OSA. Those with severe OSA had remarkably reduced HRV compared to all other groups. Compared to non-OSA patients, those with severe OSA had lower HRV based on SDNN (adjusted mean: 37.4 vs. 46.2 ms; p < 0.0001), RMSSD (21.5 vs. 27.9 ms; p < 0.0001), ShanEn (1.83 vs. 2.01; p < 0.0001), and Forbword (36.7 vs. 33.0; p = 0.0001). While no differences were found in frequency-domain measures overall, among obese patients there was a shift to sympathetic dominance in severe OSA, with a higher LF/HF ratio compared to obese non-OSA patients (4.2 vs. 2.7; p = 0.009). CONCLUSIONS Time-domain and nonlinear HRV measures during wakefulness are associated with OSA severity, with severe patients having remarkably reduced and less complex HRV. Frequency-domain measures show a shift to sympathetic dominance only in obese OSA patients. Thus, HRV during wakefulness could provide additional information about cardiovascular physiology in OSA patients. CLINICAL TRIAL INFORMATION A Prospective Observational Cohort to Study the Genetics of Obstructive Sleep Apnea and Associated Co-Morbidities (German Clinical Trials Register - DKRS, DRKS00003966) https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00003966.
Collapse
Affiliation(s)
- Hua Qin
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Brendan T Keenan
- Division of Sleep Medicine, Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
| | - Diego R Mazzotti
- Division of Medical Informatics, Department of Internal Medicine, University of Kansas Medical Center, Kansas City, KS
| | - Fernando Vaquerizo-Villar
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain
| | - Jan F Kraemer
- Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany
| | - Niels Wessel
- Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany
| | - Sergio Tufik
- Departamento de Psicobiologia, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Lia Bittencourt
- Departamento de Psicobiologia, Universidade Federal de São Paulo, São Paulo, Brazil
| | - Peter A Cistulli
- Charles Perkins Centre, Faculty of Medicine and Health, University of Sydney Sydney, Australia.,Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Philip de Chazal
- Charles Perkins Centre, Faculty of Medicine and Health, University of Sydney Sydney, Australia
| | - Kate Sutherland
- Charles Perkins Centre, Faculty of Medicine and Health, University of Sydney Sydney, Australia.,Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, Sydney, Australia
| | - Bhajan Singh
- West Australian Sleep Disorders Research Institute, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.,School of Human Sciences, University of Western Australia, Crawley, WA, Australia
| | - Allan I Pack
- Division of Sleep Medicine, Department of Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA
| | - Ning-Hung Chen
- Division of Pulmonary, Critical Care Medicine and Sleep Medicine, Chang Gung Memorial Hospital, Taoyuan City, Taiwan
| | - Ingo Fietze
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Thorarinn Gislason
- Department of Sleep Medicine, Landspitali University Hospital, Reykjavik, Iceland.,Medical Faculty, University of Iceland, Reykjavik, Iceland
| | - Steven Holfinger
- Division of Pulmonary, Critical Care, and Sleep Medicine, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Ulysses J Magalang
- Division of Pulmonary, Critical Care, and Sleep Medicine, The Ohio State University Wexner Medical Center, Columbus, OH
| | - Thomas Penzel
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
5
|
Qin H, Steenbergen N, Glos M, Wessel N, Kraemer JF, Vaquerizo-Villar F, Penzel T. The Different Facets of Heart Rate Variability in Obstructive Sleep Apnea. Front Psychiatry 2021; 12:642333. [PMID: 34366907 PMCID: PMC8339263 DOI: 10.3389/fpsyt.2021.642333] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 06/14/2021] [Indexed: 12/15/2022] Open
Abstract
Obstructive sleep apnea (OSA), a heterogeneous and multifactorial sleep related breathing disorder with high prevalence, is a recognized risk factor for cardiovascular morbidity and mortality. Autonomic dysfunction leads to adverse cardiovascular outcomes in diverse pathways. Heart rate is a complex physiological process involving neurovisceral networks and relative regulatory mechanisms such as thermoregulation, renin-angiotensin-aldosterone mechanisms, and metabolic mechanisms. Heart rate variability (HRV) is considered as a reliable and non-invasive measure of autonomic modulation response and adaptation to endogenous and exogenous stimuli. HRV measures may add a new dimension to help understand the interplay between cardiac and nervous system involvement in OSA. The aim of this review is to introduce the various applications of HRV in different aspects of OSA to examine the impaired neuro-cardiac modulation. More specifically, the topics covered include: HRV time windows, sleep staging, arousal, sleepiness, hypoxia, mental illness, and mortality and morbidity. All of these aspects show pathways in the clinical implementation of HRV to screen, diagnose, classify, and predict patients as a reasonable and more convenient alternative to current measures.
Collapse
Affiliation(s)
- Hua Qin
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | | | - Martin Glos
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Niels Wessel
- Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany
| | - Jan F Kraemer
- Department of Physics, Humboldt Universität zu Berlin, Berlin, Germany
| | - Fernando Vaquerizo-Villar
- Biomedical Engineering Group, Universidad de Valladolid, Valladolid, Spain.,Centro de Investigación Biomédica en Red-Bioingeniería, Biomateriales y Nanomedicina, Valladolid, Spain
| | - Thomas Penzel
- Interdisciplinary Center of Sleep Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Saratov State University, Russian Federation, Saratov, Russia
| |
Collapse
|
6
|
Wessel N, Berg K, Kraemer JF, Gapelyuk A, Rietsch K, Hauser T, Kurths J, Wenzel D, Klein N, Kolb C, Belke R, Schirdewan A, Kääb S. Cardiac Autonomic Dysfunction and Incidence of de novo Atrial Fibrillation: Heart Rate Variability vs. Heart Rate Complexity. Front Physiol 2020; 11:596844. [PMID: 33363477 PMCID: PMC7752808 DOI: 10.3389/fphys.2020.596844] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 11/13/2020] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The REACT DX registry evaluates standard therapies to episodes of long-lasting atrial tachyarrhythmias and assesses the quality of sensing and stability of the lead and the implantable cardioverter-defibrillator (ICD) (BIOTRONIK Lumax VR-T DX and successors) over at least a 1-year follow-up period. OBJECTIVE To study the association between the risk of de novo device-detected atrial fibrillation (AF), the autonomic perturbations before the onset of paroxysmal AF and a 7-days heart rate variability (7dHRV) 1 month after ICD implantation. METHODS The registry consists of 234 patients implanted with an ICD, including 10 with de novo long-lasting atrial tachyarrhythmias with no prior history of AF. The patients were matched via the propensity-score methodology as well as for properties directly influencing the ECGs recorded using GE CardioMem CM 3000. Heart rate variability (HRV) analysis was performed using standard parameters from time- and frequency-domains, and from non-linear dynamics. RESULTS No linear HRV was associated with an increased risk of AF (p = n.s.). The only significant approach was derived from symbolic dynamics with the parameter "forbidden words" which distinguished both groups on all 7 days of measurements (p < 0.05), thereby quantifying the heart rate complexity (HRC) as drastically lower in the de novo AF group. CONCLUSION Cardiac autonomic dysfunction denoted by low HRC may be associated with higher AF incidence. For patients with mild to moderate heart failure, standard HRV parameters are not appropriate to quantify cardiac autonomic perturbations before the onset of AF. Further studies are needed to determine the individual risk for AF that would enable interventions to restore autonomic balance in the general population.
Collapse
Affiliation(s)
- Niels Wessel
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Karsten Berg
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jan F. Kraemer
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Andrej Gapelyuk
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | | | | | - Jürgen Kurths
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
- Potsdam Institute for Climate Impact Research, Potsdam, Germany
- Centre for Analysis of Complex Systems, Sechenov First Moscow State Medical University, Moscow, Russia
| | - Dave Wenzel
- Clinic for Cardiology and Angiology, University Hospital Magdeburg, Magdeburg, Germany
| | | | - Christof Kolb
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany
| | | | | | - Stefan Kääb
- Medical Center of Ludwig-Maximilians-University of Munich, Munich, Germany
| |
Collapse
|
7
|
Wessel N, Gapelyuk A, Weiß J, Schmidt M, Kraemer JF, Berg K, Malberg H, Stepan H, Kurths J. Instantaneous Cardiac Baroreflex Sensitivity: xBRS Method Quantifies Heart Rate Blood Pressure Variability Ratio at Rest and During Slow Breathing. Front Neurosci 2020; 14:547433. [PMID: 33071732 PMCID: PMC7543095 DOI: 10.3389/fnins.2020.547433] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Accepted: 09/04/2020] [Indexed: 11/13/2022] Open
Abstract
Spontaneous baroreflex sensitivity (BRS) is a widely used tool for the quantification of the cardiovascular regulation. Numerous groups use the xBRS method, which calculates the cross-correlation between the systolic beat-to-beat blood pressure and the R-R interval (resampled at 1 Hz) in a 10 s sliding window, with 0-5 s delays for the interval. The delay with the highest correlation is selected and, if significant, the quotient of the standard deviations of the R-R intervals and the systolic blood pressures is recorded as the corresponding xBRS value. In this paper we test the hypothesis that the xBRS method quantifies the causal interactions of spontaneous BRS from non-invasive measurements at rest. We use the term spontaneous BRS in the sense of the sensitivity curve is calculated from non-interventional, i.e., spontaneous, baroreceptor activity. This study includes retrospective analysis of 1828 measurements containing ECG as well as continues blood pressure under resting conditions. Our results show a high correlation between the heart rate - systolic blood pressure variability (HRV/BPV) quotient and the xBRS (r = 0.94, p < 0.001). For a deeper understanding we conducted two surrogate analyses by substituting the systolic blood pressure by its reversed time series. These showed that the xBRS method was not able to quantify causal relationships between the two signals. It was not possible to distinguish between random and baroreflex controlled sequences. It appears xBRS rather determines the HRV/BPV quotient. We conclude that the xBRS method has a potentially large bias in characterizing the capacity of the arterial baroreflex under resting conditions. During slow breathing, estimates for xBRS are significantly increased, which clearly shows that measurements at rest only involve limited baroreflex activity, but does neither challenge, nor show the full range of the arterial baroreflex regulatory capacity. We show that xBRS is exclusively dominated by the heart rate to systolic blood pressure ratio (r = 0.965, p < 0.001). Further investigations should focus on additional autonomous testing procedures such as slow breathing or orthostatic testing to provide a basis for a non-invasive evaluation of baroreflex sensitivity.
Collapse
Affiliation(s)
- Niels Wessel
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Andrej Gapelyuk
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jonas Weiß
- Institute of Biomedical Engineering, Technische Universität Dresden, Dresden, Germany
| | - Martin Schmidt
- Institute of Biomedical Engineering, Technische Universität Dresden, Dresden, Germany
| | - Jan F Kraemer
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Karsten Berg
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Hagen Malberg
- Institute of Biomedical Engineering, Technische Universität Dresden, Dresden, Germany
| | - Holger Stepan
- Division of Obstetrics, Universitätsklinikum Leipzig, Leipzig, Germany
| | - Jürgen Kurths
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany.,Potsdam Institute for Climate Impact Research, Potsdam, Germany.,Department of Human and Animal Physiology, Saratov State University, Saratov, Russia
| |
Collapse
|
8
|
Wessel N, Gapelyuk A, Kraemer JF, Berg K, Kurths J. Spontaneous baroreflex sensitivity: sequence method at rest does not quantify causal interactions but rather determines the heart rate to blood pressure variability ratio. Physiol Meas 2020; 41:03LT01. [PMID: 32160607 DOI: 10.1088/1361-6579/ab7edc] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- N Wessel
- Humboldt-Universität zu Berlin, Berlin, Germany
| | | | | | | | | |
Collapse
|
9
|
Thiesse L, Rudzik F, Kraemer JF, Spiegel K, Leproult R, Wessel N, Pieren R, Héritier H, Eze IC, Foraster M, Garbazza C, Vienneau D, Brink M, Wunderli JM, Probst-Hensch N, Röösli M, Cajochen C. Transportation noise impairs cardiovascular function without altering sleep: The importance of autonomic arousals. Environ Res 2020; 182:109086. [PMID: 32069756 DOI: 10.1016/j.envres.2019.109086] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2019] [Revised: 12/22/2019] [Accepted: 12/23/2019] [Indexed: 05/15/2023]
Abstract
AIMS Chronic exposure to nocturnal transportation noise has been linked to cardiovascular disorders with sleep impairment as the main mediator. Here we examined whether nocturnal transportation noise affects the main stress pathways, and whether it relates to changes in the macro and micro structure of sleep. METHODS AND RESULTS Twenty-six young healthy participants (12 women, 24.6 ± 0.7 years, mean ± SE) spent five consecutive 24-h days and one last morning in the laboratory. The first (baseline) and last (recovery) nights comprised a quiet ambient scenario. In-between, four different noise scenarios (low/medium/high intermittent road or rail scenarios with an identical equivalent continuous sound level of 45 dB) were randomly presented during the 8-h nights. Participants felt more annoyed from the transportation noise scenarios compared to the quiet ambient scenario played back during the baseline and recovery nights (F5,117 = 10.2, p < 0.001). Nocturnal transportation noise did not significantly impact polysomnographically assessed sleep macrostructure, blood pressure, nocturnal catecholamine levels and morning cytokine levels. Evening cortisol levels increased after sleeping with highly intermittent road noise compared to baseline (p = 0.002, noise effect: F4,83 = 4.0, p = 0.005), a result related to increased cumulative duration of autonomic arousals during the noise nights (F5,106 = 3.4, p < 0.001; correlation: rpearson = 0.64, p = 0.006). CONCLUSION Under controlled laboratory conditions, highly intermittent nocturnal road noise exposure at 45 dB increased the cumulative duration of autonomic arousals during sleep and next-day evening cortisol levels. Our results indicate that, without impairing sleep macrostructure, nocturnal transportation noise of 45 dB is a physiological stressor that affects the hypothalamic-pituitary-adrenal axis during the following day in healthy young good sleepers.
Collapse
Affiliation(s)
- Laurie Thiesse
- Centre for Chronobiology, Psychiatric Hospital of the University of Basel, Switzerland; Transfaculty Research Platform Molecular and Cognitive Neurosciences, University of Basel, Switzerland
| | - Franziska Rudzik
- Centre for Chronobiology, Psychiatric Hospital of the University of Basel, Switzerland; Transfaculty Research Platform Molecular and Cognitive Neurosciences, University of Basel, Switzerland
| | - Jan F Kraemer
- Department of Physics, Humboldt-Universität ZU Berlin, Germany
| | - Karine Spiegel
- WAKING Team, Lyon Neuroscience Research Center (CRNL) - INSERM U1028, CNRS UMR5292, University Claude Bernard Lyon 1, Lyon, France
| | - Rachel Leproult
- Université libre de Bruxelles (ULB), Avenue F.D. Roosevelt 50, Bruxelles, Belgium
| | - Niels Wessel
- Department of Physics, Humboldt-Universität ZU Berlin, Germany
| | - Reto Pieren
- Empa - Swiss Federal Laboratories for Materials Science and Technology, Duebendorf, Switzerland
| | - Harris Héritier
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland
| | - Ikenna C Eze
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland
| | - Maria Foraster
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland; ISGlobal, Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Barcelona, Spain; Blanquerna School of Health Science, Universitat Ramon Llull, Barcelona, Spain
| | - Corrado Garbazza
- Centre for Chronobiology, Psychiatric Hospital of the University of Basel, Switzerland; Transfaculty Research Platform Molecular and Cognitive Neurosciences, University of Basel, Switzerland
| | - Danielle Vienneau
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland
| | - Mark Brink
- Swiss Federal Office for the Environment, Bern, Switzerland
| | - Jean Marc Wunderli
- Empa - Swiss Federal Laboratories for Materials Science and Technology, Duebendorf, Switzerland
| | - Nicole Probst-Hensch
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland
| | - Martin Röösli
- Swiss Tropical and Public Health Institute, Basel, Switzerland; University of Basel, Basel, Switzerland
| | - Christian Cajochen
- Centre for Chronobiology, Psychiatric Hospital of the University of Basel, Switzerland; Transfaculty Research Platform Molecular and Cognitive Neurosciences, University of Basel, Switzerland.
| |
Collapse
|
10
|
Lyons MM, Kraemer JF, Dhingra R, Keenan BT, Wessel N, Glos M, Penzel T, Gurubhagavatula I. Screening for Obstructive Sleep Apnea in Commercial Drivers Using EKG-Derived Respiratory Power Index. J Clin Sleep Med 2019; 15:23-32. [PMID: 30621825 DOI: 10.5664/jcsm.7562] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Accepted: 08/17/2018] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Obstructive sleep apnea (OSA) is common in commercial motor vehicle operators (CMVOs); however, polysomnography (PSG), the gold-standard diagnostic test, is expensive and inconvenient for screening. OSA is associated with changes in heart rate and voltage on electrocardiography (EKG). We evaluated the utility of EKG parameters in identifying CMVOs at greater risk for sleepiness-related crashes (apnea-hypopnea index [AHI] ≥ 30 events/h). METHODS In this prospective study of CMVOs, we performed EKGs with concurrent PSG, and calculated the respiratory power index (RPI) on EKG, a surrogate for AHI calculated from PSG. We evaluated the utility of two-stage predictive models using simple clinical measures (age, body mass index [BMI], neck circumference, Epworth Sleepiness Scale score, and the Multi-Variable Apnea Prediction [MVAP] score) in the first stage, followed by RPI in a subset as the second-stage. We assessed area under the receiver operating characteristic curve (AUC), sensitivity, and negative posttest probability (NPTP) for this two-stage approach and for RPI alone. RESULTS The best-performing model used the MVAP, which combines BMI, age, and sex with three OSA symptoms, in the first stage, followed by RPI in the second. The model yielded an estimated (95% confidence interval) AUC of 0.883 (0.767-0.924), sensitivity of 0.917 (0.706-0.962), and NPTP of 0.034 (0.015-0.133). Predictive characteristics were similar using a model with only BMI as the first-stage screen. CONCLUSIONS A two-stage model that combines BMI or the MVAP score in the first stage, with EKG in the second, had robust discriminatory power to identify severe OSA in CMVOs.
Collapse
Affiliation(s)
- M Melani Lyons
- Center for Sleep and Circadian Neurobiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Jan F Kraemer
- Department of Physics, Humboldt-Universitat zu Berlin, Berlin, Germany
| | - Radha Dhingra
- Mahatma Gandhi Medical College and Hospital, Jaipur, India
| | - Brendan T Keenan
- Center for Sleep and Circadian Neurobiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Niels Wessel
- Department of Physics, Humboldt-Universitat zu Berlin, Berlin, Germany
| | - Martin Glos
- The Centre of Sleep Medicine, Department of Cardiology, Charité Universitätsmedizin, Berlin, Berlin, Germany
| | - Thomas Penzel
- The Centre of Sleep Medicine, Department of Cardiology, Charité Universitätsmedizin, Berlin, Berlin, Germany
| | - Indira Gurubhagavatula
- Center for Sleep and Circadian Neurobiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.,Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania.,Sleep Disorders Clinic at the Philadelphia CMC VA Medical Center, Philadelphia, Pennsylvania
| |
Collapse
|
11
|
Järve A, Todiras M, Kny M, Fischer FI, Kraemer JF, Wessel N, Plehm R, Fielitz J, Alenina N, Bader M. Angiotensin-(1-7) Receptor Mas in Hemodynamic and Thermoregulatory Dysfunction After High-Level Spinal Cord Injury in Mice: A Pilot Study. Front Physiol 2019; 9:1930. [PMID: 30687131 PMCID: PMC6336833 DOI: 10.3389/fphys.2018.01930] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 12/21/2018] [Indexed: 01/12/2023] Open
Abstract
Spinal cord injury (SCI) above mid-thoracic levels leads to autonomic dysfunction affecting both the cardiovascular system and thermoregulation. The renin-angiotensin system (RAS) which is a potent regulator of blood pressure, including its novel beneficial arm with the receptor Mas could be an interesting target in post-SCI hemodynamics. To test the hypothesis that hemodynamics, activity and diurnal patterns of those are more affected in the Mas deficient mice post-SCI we used a mouse model of SCI with complete transection of spinal cord at thoracic level 4 (T4-Tx) and performed telemetric monitoring of blood pressure (BP) and heart rate (HR). Our data revealed that hypothermia deteriorated physiological BP and HR control. Preserving normothermia by keeping mice at 30°C prevented severe hypotension and bradycardia post-SCI. Moreover, it facilitated rapid return of diurnal regulation of BP, HR and activity in wild type (WT) mice. In contrast, although Mas deficient mice had comparable reacquisition of diurnal HR rhythm, they showed delayed recovery of diurnal rhythmicity in BP and significantly lower nocturnal activity. Exposing mice with T4-Tx (kept in temperature-controlled cages) to 23°C room temperature for one hour at different time-points post-SCI, demonstrated their inability to maintain core body temperature, Mas deficient mice being significantly more impaired than WT littermates. We conclude that Mas deficient mice were more resistant to acute hypotension, delayed nocturnal recovery, lower activity and more severely impaired thermoregulation. The ambient temperature had significant effect on hemodynamics and, thus it should be taken into account when assessing cardiovascular parameters post-SCI in mice.
Collapse
Affiliation(s)
- Anne Järve
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Partner Site Berlin, German Centre for Cardiovascular Research, Berlin, Germany
| | - Mihail Todiras
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Melanie Kny
- Experimental and Clinical Research Center, Max Delbrück Center for Molecular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Falk I Fischer
- Experimental and Clinical Research Center, Max Delbrück Center for Molecular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Jan F Kraemer
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Niels Wessel
- Department of Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Ralph Plehm
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jens Fielitz
- Experimental and Clinical Research Center, Max Delbrück Center for Molecular Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany.,Partner Site Greifswald, German Centre for Cardiovascular Research, Greifswald, Germany.,Klinik und Poliklinik für Innere Medizin B, Universitätsmedizin Greifswald, Greifswald, Germany
| | - Natalia Alenina
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Partner Site Berlin, German Centre for Cardiovascular Research, Berlin, Germany
| | - Michael Bader
- Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Partner Site Berlin, German Centre for Cardiovascular Research, Berlin, Germany.,Charité - Universitätsmedizin Berlin, Berlin, Germany.,Berlin Institute of Health, Berlin, Germany.,Institute of Biology, University of Lübeck, Lübeck, Germany
| |
Collapse
|
12
|
Granitza P, Kraemer JF, Schoebel C, Penzel T, Kurths J, Wessel N. Is dynamic desaturation better than a static index to quantify the mortality risk in heart failure patients with Cheyne-Stokes respiration? Chaos 2018; 28:106312. [PMID: 30384661 DOI: 10.1063/1.5039601] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 09/23/2018] [Indexed: 06/08/2023]
Abstract
Cheyne-Stokes respiration (CSR) is a periodic, highly dynamic, respiratory pattern and a known comorbidity in congestive heart failure (CHF) patients. It is generally seen as an indicator for a negative prognosis, even if no distinction in degree is known or understood. This paper aims to improve on existing attempts by creating a quantification of the behavior of the dynamic desaturation process of oxygen in the blood. We performed this work on a cohort of 11 subjects with CHF, reduced left ventricular ejection fraction, and CSR. The dynamic desaturation process was evaluated according to changes to peripheral capillary oxygenation S p O 2 resulting from highly nonlinear relationships in the ventilatory system perturbed by periodic breathing. Hypoxaemic burden expressed as a static index T 90 was compared to a novel relative desaturation index R D I , developed in this paper. While T 90 represents a single value calculated using a static cut-off value of 90 % S p O 2 , the R D I is more sensitive to dynamic influences as it uses the specific maximum change in saturation for each CSR episode. The threshold of T 90 = 22 min per night as suggested by Oldenburg et al. could not be confirmed to predict survival, but all central apneas resulting in a relative desaturation of S p O 2 above a cut-off value of 8 % were a 100 % positive predictor of mortality. The R D I proved sufficiently stable in intraindividual measurements across CSR epochs. Across the cohort, it showed a bimodal distribution for the deceased group, indicative of a possible aetiological difference. Hence, it is our conclusion that a dynamic approach to analyse desaturation of oxygen during Cheyne-Stokes respiration is to be strongly favoured over a static approach to analysis.
Collapse
Affiliation(s)
- Philine Granitza
- Department of Physics, Cardiovascular Physics, Humboldt-Universität zu Berlin, 10099 Berlin, Germany
| | - Jan F Kraemer
- Department of Physics, Cardiovascular Physics, Humboldt-Universität zu Berlin, 10099 Berlin, Germany
| | - Christoph Schoebel
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany
| | - Thomas Penzel
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany
| | - Jürgen Kurths
- Department of Physics, Cardiovascular Physics, Humboldt-Universität zu Berlin, 10099 Berlin, Germany
| | - Niels Wessel
- Department of Physics, Cardiovascular Physics, Humboldt-Universität zu Berlin, 10099 Berlin, Germany
| |
Collapse
|
13
|
Wessel N, Sidorenko L, Kraemer JF, Schoebel C, Baumann G. Assessing cardiac autonomic function via heart rate variability analysis requires monitoring respiration. Europace 2017; 18:1280. [PMID: 27496953 DOI: 10.1093/europace/euv460] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- N Wessel
- Humboldt-Universität zu Berlin, Berlin, Germany
| | - L Sidorenko
- Humboldt-Universität zu Berlin, Berlin, Germany
| | - J F Kraemer
- Humboldt-Universität zu Berlin, Berlin, Germany
| | - C Schoebel
- Humboldt-Universität zu Berlin, Berlin, Germany
| | - G Baumann
- Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
14
|
Krause H, Kraemer JF, Penzel T, Kurths J, Wessel N. On the difference of cardiorespiratory synchronisation and coordination. Chaos 2017; 27:093933. [PMID: 28964129 DOI: 10.1063/1.4999352] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Accepted: 05/18/2017] [Indexed: 06/07/2023]
Abstract
Cardiorespiratory phase synchronisation (CRS) is a type of cardiorespiratory coupling that manifests through a prediliction for heart beats to occur at specific points relative to the phase of the respiratory cycle. It has been under investigation for nearly 20 years, and while it seems to be mostly occurring in relaxed states such as deep sleep and anesthesia, no clear clinical implications have been established. Cardiorespiratory coordination (CRC) is a recent development in this field where the relationship between the respiratory onset and heart beat is analysed in the time domain and the possible relationship of each heart beat is considered for both the previous and the next respiratory onset. This ostensibly closely related effect must not only show relevant information content but also do so independent of CRS in order to be relevant for future studies. In this paper, we investigate CRC and its relation to CRS mainly using graphical and statistical methods on two exemplary datasets: measurements from a pregnant woman participating in a preeclampsia study and those from a man suffering from sleep apnea. We show fundamental differences between the results of both approaches and are able to show a formerly unknown dependency between the heart activity and respiratory rate, potentially indicating heartbeat-initiated inspiration. Despite their differences, methods developed for the quantification of CRS can be adapted to CRC. Completing the comparison is an investigation into the relationship between CRC and respiratory sinus arrhythmia. Similar to previous results for CRS, the two effects are found to be orthogonal, meaning that they can be observed independently or in conjunction.
Collapse
Affiliation(s)
- Harald Krause
- AG NLD - Cardiovascular Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jan F Kraemer
- AG NLD - Cardiovascular Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Thomas Penzel
- AG NLD - Cardiovascular Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jürgen Kurths
- AG NLD - Cardiovascular Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| | - Niels Wessel
- AG NLD - Cardiovascular Physics, Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
15
|
|
16
|
Miyabara R, Berg K, Kraemer JF, Baltatu OC, Wessel N, Campos LA. Quantifying Effects of Pharmacological Blockers of Cardiac Autonomous Control Using Variability Parameters. Front Physiol 2017; 8:10. [PMID: 28167918 PMCID: PMC5253391 DOI: 10.3389/fphys.2017.00010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Accepted: 01/06/2017] [Indexed: 01/11/2023] Open
Abstract
Objective: The aim of this study was to identify the most sensitive heart rate and blood pressure variability (HRV and BPV) parameters from a given set of well-known methods for the quantification of cardiovascular autonomic function after several autonomic blockades. Methods: Cardiovascular sympathetic and parasympathetic functions were studied in freely moving rats following peripheral muscarinic (methylatropine), β1-adrenergic (metoprolol), muscarinic + β1-adrenergic, α1-adrenergic (prazosin), and ganglionic (hexamethonium) blockades. Time domain, frequency domain and symbolic dynamics measures for each of HRV and BPV were classified through paired Wilcoxon test for all autonomic drugs separately. In order to select those variables that have a high relevance to, and stable influence on our target measurements (HRV, BPV) we used Fisher's Method to combine the p-value of multiple tests. Results: This analysis led to the following best set of cardiovascular variability parameters: The mean normal beat-to-beat-interval/value (HRV/BPV: meanNN), the coefficient of variation (cvNN = standard deviation over meanNN) and the root mean square differences of successive (RMSSD) of the time domain analysis. In frequency domain analysis the very-low-frequency (VLF) component was selected. From symbolic dynamics Shannon entropy of the word distribution (FWSHANNON) as well as POLVAR3, the non-linear parameter to detect intermittently decreased variability, showed the best ability to discriminate between the different autonomic blockades. Conclusion: Throughout a complex comparative analysis of HRV and BPV measures altered by a set of autonomic drugs, we identified the most sensitive set of informative cardiovascular variability indexes able to pick up the modifications imposed by the autonomic challenges. These indexes may help to increase our understanding of cardiovascular sympathetic and parasympathetic functions in translational studies of experimental diseases.
Collapse
Affiliation(s)
- Renata Miyabara
- Center of Innovation, Technology and Education (CITE), Anhembi Morumbi University - Laureate International UniversitiesSao Jose dos Campos, Brazil; Center of Innovation, Technology and Education (CITE), Camilo Castelo Branco UniversitySao Jose dos Campos, Brazil
| | - Karsten Berg
- Institut für Physik, Humboldt-Universität zu Berlin Berlin, Germany
| | - Jan F Kraemer
- Institut für Physik, Humboldt-Universität zu Berlin Berlin, Germany
| | - Ovidiu C Baltatu
- Center of Innovation, Technology and Education (CITE), Anhembi Morumbi University - Laureate International UniversitiesSao Jose dos Campos, Brazil; Center of Innovation, Technology and Education (CITE), Camilo Castelo Branco UniversitySao Jose dos Campos, Brazil
| | - Niels Wessel
- Institut für Physik, Humboldt-Universität zu Berlin Berlin, Germany
| | - Luciana A Campos
- Center of Innovation, Technology and Education (CITE), Anhembi Morumbi University - Laureate International UniversitiesSao Jose dos Campos, Brazil; Center of Innovation, Technology and Education (CITE), Camilo Castelo Branco UniversitySao Jose dos Campos, Brazil
| |
Collapse
|
17
|
Penzel T, Kantelhardt JW, Bartsch RP, Riedl M, Kraemer JF, Wessel N, Garcia C, Glos M, Fietze I, Schöbel C. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography. Front Physiol 2016; 7:460. [PMID: 27826247 PMCID: PMC5078504 DOI: 10.3389/fphys.2016.00460] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Accepted: 09/23/2016] [Indexed: 11/13/2022] Open
Abstract
The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).
Collapse
Affiliation(s)
- Thomas Penzel
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité - Universitätsmedizin BerlinBerlin, Germany; International Clinical Research Center, St. Anne's University Hospital BrnoBrno, Czech Republic
| | - Jan W Kantelhardt
- Naturwissenschaftliche Fakultät II - Chemie, Physik und Mathematik, Institut für Physik, Martin-Luther Universität Halle-WittenbergHalle, Germany; Kardiovaskuläre Physik, Arbeitsgruppe Nichtlineare Dynamik, Fachbereich Physik, Humboldt-Universität BerlinBerlin, Germany
| | | | - Maik Riedl
- Kardiovaskuläre Physik, Arbeitsgruppe Nichtlineare Dynamik, Fachbereich Physik, Humboldt-Universität Berlin Berlin, Germany
| | - Jan F Kraemer
- Kardiovaskuläre Physik, Arbeitsgruppe Nichtlineare Dynamik, Fachbereich Physik, Humboldt-Universität Berlin Berlin, Germany
| | - Niels Wessel
- Kardiovaskuläre Physik, Arbeitsgruppe Nichtlineare Dynamik, Fachbereich Physik, Humboldt-Universität Berlin Berlin, Germany
| | - Carmen Garcia
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité - Universitätsmedizin Berlin Berlin, Germany
| | - Martin Glos
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité - Universitätsmedizin Berlin Berlin, Germany
| | - Ingo Fietze
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité - Universitätsmedizin Berlin Berlin, Germany
| | - Christoph Schöbel
- Interdisziplinäres Schlafmedizinisches Zentrum, Charité - Universitätsmedizin Berlin Berlin, Germany
| |
Collapse
|
18
|
Sidorenko L, Kraemer JF, Wessel N. Standard heart rate variability spectral analysis: does it purely assess cardiac autonomic function? Europace 2016; 18:1085. [PMID: 27174902 DOI: 10.1093/europace/euw078] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- L Sidorenko
- State University of Medicine and Pharmacy "Nicolae Testemitanu", Chişinău, Republic of Moldova Humboldt-Universität zu Berlin, Berlin, Germany
| | - J F Kraemer
- Humboldt-Universität zu Berlin, Berlin, Germany
| | - N Wessel
- Humboldt-Universität zu Berlin, Berlin, Germany
| |
Collapse
|
19
|
|
20
|
Kraemer JF, Bönke A, Wessel N. Steps towards evaluating cardio-respiratory synchronicity in protective ventilation. J Crit Care 2013. [DOI: 10.1016/j.jcrc.2012.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
Gapelyuk A, Riedl M, Suhrbier A, Kraemer JF, Bretthauer G, Malberg H, Kurths J, Penzel T, Wessel N. Cardiovascular regulation in different sleep stages in the obstructive sleep apnea syndrome. ACTA ACUST UNITED AC 2011; 56:207-13. [DOI: 10.1515/bmt.2011.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|