1
|
Amoretti N, Huwart L. Combination of percutaneous osteosynthesis and vertebroplasty of thoracolumbar split fractures under CT and fluoroscopy guidance: a new technique. Cardiovasc Intervent Radiol 2014; 37:1363-8. [PMID: 24482031 DOI: 10.1007/s00270-014-0849-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Accepted: 12/23/2013] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The purpose of our study was to evaluate the technical feasibility of the combination involving percutaneous screw fixation and vertebroplasty in split fractures of thoracolumbar spine. METHODS Institutional review board approval and informed consent were obtained. Ten consecutive adult patients who had posttraumatic vertebral split fractures (Magerl A2) were prospectively treated by an interventional radiologist under computed tomography and fluoroscopy guidance. Using a bilateral route under local anesthesia, one 4.0-mm cannulated screw was placed on one side to fix the fracture, and on the other side, vertebroplasty was performed. Follow-up ranging from 12 to 24 months was assessed using visual analog scale (VAS) and Oswestry disability index (ODI) RESULTS: Combined procedures were performed on thoracic and lumbar vertebrae, creating both osteosynthesis and cement bridge between the displaced fragment and the rest of the vertebral body. Mean VAS measurements ± standard deviation (SD) decreased from 7.5 ± 1.5 preoperatively to 3.2 ± 1.9 at 1 day, 2.1 ± 1.2 at 1 month, and 1.9 ± 1.4 at the last examination (P < 0.001). Mean ODI scores ± SD decreased from 65.3 ± 16.2, preoperatively, to 16.1 ± 5.0 at the final examination (P < 0.001). CONCLUSIONS This study suggests that type A2 vertebral fractures could be successfully stabilized by the combination of percutaneous osteosynthesis and vertebroplasty.
Collapse
Affiliation(s)
- Nicolas Amoretti
- Department of Radiology, Centre Hospitalo-Universitaire de Nice, Hôpital Archet 2, 151, route Saint-Antoine de Ginestière, 06200, Nice, France
| | | |
Collapse
|
2
|
Amoretti N, Amoretti ME, Hovorka I, Hauger O, Boileau P, Huwart L. Percutaneous facet screw fixation of lumbar spine with CT and fluoroscopic guidance: a feasibility study. Radiology 2013; 268:548-55. [PMID: 23481163 DOI: 10.1148/radiol.13120907] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To assess the feasibility of computed tomography (CT)- and fluoroscopy-guided percutaneous facet screw fixation following anterior lumbar interbody fusion (ALIF) or anterior pseudarthrosis in adults. MATERIALS AND METHODS Institutional review board approval and informed consent were obtained for this study. One hundred seven consecutive adult patients (46 men, 61 women; mean age ± standard deviation: 56.3 years ± 12.9) with ALIF (n = 79) or anterior pseudarthrosis (n = 28) were prospectively treated by means of percutaneous facet screw fixation with CT and fluoroscopic guidance. Two 4.0-mm cannulated screws were placed per level to fix facet joints by using either a translaminar facet or transfacet pedicle pathway. Only local anesthesia was used during these procedures. Procedural time was noted for each patient. Postoperative follow-up ranging from 1 year to 3 years was assessed by using Macnab and radiologic criteria. RESULTS The mean procedure times for a lumbar single-level and a double-level fusion ranged from 15 to 25 minutes and from 40 to 50 minutes, respectively. All the transfacet pedicle (n = 182) and translaminar facet (n = 56) screws were successfully placed in one attempt. Radiographic fusion was observed within the year following posterior fixation in all patients despite one translaminar screw failure. According to the Macnab criteria, the clinical results were classified as excellent in 92 (86%) and good in 15 (14%) of 107 patients at the time of their last follow-up examination. CONCLUSION This feasibility study showed that CT- and fluoroscopy-guided percutaneous facet screw fixation is a rapid, safe, and effective method.
Collapse
Affiliation(s)
- Nicolas Amoretti
- Departments of Radiology, Hôpital Archet 2, Teaching Hospital of Nice, 151 route Saint-Antoine de Ginestière, 06200 Nice, France
| | | | | | | | | | | |
Collapse
|
3
|
Amoretti N, Huwart L, Marcy PY, Foti P, Hauger O, Boileau P. CT- and fluoroscopy-guided percutaneous discectomy for lumbar radiculopathy related to disc herniation: a comparative prospective study comparing lateral to medial herniated discs. Skeletal Radiol 2013; 42:49-53. [PMID: 22644540 DOI: 10.1007/s00256-012-1422-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 01/09/2012] [Accepted: 04/23/2012] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To evaluate and compare two groups of patients with sciatica due to intervertebral disc herniation with no neurologic deficit. The groups consisted of patients with intervertebral disc herniation in a medial location (group 1) and those in a lateral location (group 2). MATERIALS AND METHODS A total of 200 patients were included in the study and were followed for a minimum of 6 months. In our series, we treated 80 postero-lateral herniated discs (40% of cases), 46 postero-medial herniated discs (23%), and 74 foraminal herniated discs (37%). Level L3-L4 was treated in 30 cases (15%), L4-L5 in 98 cases (49%), and L5-S1 in 72 cases (36%). The procedure was performed under dual guidance: fluoroscopic and CT. A helical probe was activated. It penetrates the herniated disc and causes the pulpous material to be mechanically evacuated through the probe. All 200 patients were followed for a minimum of 6 months. RESULTS In group 1, the patients had a mean pain score of 7.9 ± 2.5 VAS units (range 6-10 units) prior to intervention. This was reduced to 3.2 ± 2.1 VAS units (range 0-10 units) at 48 h follow-up and increased to 3.9 ± 1.2 VAS units (range 0-10 VAS units) at 1 month follow-up and further reduced to 2.7 ± 1.2 units (range 0-10 VAS units) at 6 month follow-up. In group 2, the patients had a mean pain score of 8.2 ± 3.2 VAS units (range 6-10 units) prior to intervention. This was reduced to 2.8 ± 1.5 VAS units (range 0-10 units) at 48 h follow-up and decreased to 1.5 ± 0.9 VAS units (range 0-10 units) at 1 month and further reduced to 1.1 ± 0.5 VAS units (range 0-10 units) at 6 months. CONCLUSION Our study showed that results were more satisfactory for the hernia located laterally (postero-lateral, foraminal, and extra-foraminal) as compared to the hernia located posteromedially.
Collapse
Affiliation(s)
- Nicolas Amoretti
- Department of Radiology, Hôpital archet 2, Centre Hospital-Universitaire de Nice, 151, route de saint antoine de Ginestière, 06200, Nice, France.
| | | | | | | | | | | |
Collapse
|
4
|
Amoretti N, Huwart L. Percutaneous screw fixation of a talar fracture under computed tomography and fluoroscopy guidance. J Vasc Interv Radiol 2012. [PMID: 23177119 DOI: 10.1016/j.jvir.2012.09.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
5
|
Amoretti N, Huwart L, Hauger O, Browaeys P, Marcy PY, Nouri Y, Ibba C, Boileau P. Computed tomography- and fluoroscopy-guided percutaneous screw fixation of low-grade isthmic spondylolisthesis in adults: a new technique. Eur Radiol 2012; 22:2841-7. [DOI: 10.1007/s00330-012-2536-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Revised: 04/23/2012] [Accepted: 04/27/2012] [Indexed: 10/28/2022]
|
6
|
Amoretti N, Huwart L, Foti P, Boileau P, Amoretti ME, Pellegrin A, Marcy PY, Hauger O. Symptomatic lumbar facet joint cysts treated by CT-guided intracystic and intra-articular steroid injections. Eur Radiol 2012; 22:2836-40. [DOI: 10.1007/s00330-012-2533-z] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2011] [Revised: 04/23/2012] [Accepted: 04/27/2012] [Indexed: 11/30/2022]
|
7
|
Amoretti N, Huwart L. Percutaneous extraction of cement leakage after vertebroplasty under CT and fluoroscopy guidance: a new technique. Cardiovasc Intervent Radiol 2012; 35:1492-5. [PMID: 22610299 DOI: 10.1007/s00270-012-0414-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Accepted: 04/06/2012] [Indexed: 11/29/2022]
Abstract
PURPOSE We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. METHODS Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t'am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. RESULTS In each patient, all cement fragments were withdrawn within 10 min, without complication. CONCLUSIONS This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.
Collapse
Affiliation(s)
- Nicolas Amoretti
- Department of Radiology, Centre Hospitalo-Universitaire de Nice, Hôpital Archet 2, 151, Route Saint-Antoine de Ginestière, 06200, Nice, France.
| | | |
Collapse
|
8
|
Amoretti N, Hauger O, Poussange N, Browaeys P, Huwart L, Marcy PY, Amoretti ME, Hovorka I, Coco L, Benzaken T, Nouri Y, Bronsard N, Ibba C, Boileau P. Discoscanner : indications, technique, trucs et astuces, interprétation. J Neuroradiol 2012; 39:44-50. [DOI: 10.1016/j.neurad.2011.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2011] [Revised: 05/09/2011] [Accepted: 05/28/2011] [Indexed: 11/16/2022]
|
9
|
Hoeffel C, Mulé S, Huwart L, Frouin F, Jais JP, Helenon O, Correas JM. Renal blood flow quantification in pigs using contrast-enhanced ultrasound: an ex vivo study. Ultraschall Med 2010; 31:363-369. [PMID: 20408121 DOI: 10.1055/s-0029-1245238] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
PURPOSE The aim of the study was to evaluate a new method for the quantification of renal blood flow using contrast-enhanced ultrasound (CEUS) in an ex vivo pig kidney model. MATERIAL AND METHODS After approval by the animal ethics committee, 4 pig kidneys were explanted and perfused with Celsior liquid (Imtix Sangstat, Lyon, France) at different flow rates (30, 50, 70 and 90 ml/min) in an ex vivo phantom. A 50 % diluted solution of SonoVue (Bracco, Milano, Italy) was infused in the artery at 0.5 ml/min. CEUS was performed with an Aplio system (Toshiba, Nasu, Japan) using a broadband linear transducer and pulse subtraction imaging. A total of 152 destruction-reperfusion sequences were acquired and cine loops were digitally stored for further quantification. Three different ROIs were placed upon the anterior, posterior cortex and segmental artery. Signal intensity measurements were performed in linear units and perfusion parameters were automatically extracted using dedicated software. Curve fitting was performed using a monoexponential model in which a time delay parameter was introduced. This fit allowed the assessment of the local blood flow into the region of interest (called "contrast-enhanced blood flow" (CEBF)). The artery mean signal intensity was averaged from the ten frames prior to the destruction phase. The normalized CEBF (nCEBF) was calculated as the ratio between CEBF and the mean arterial signal intensity. The CEBF and nCEBF were compared to the true blood flow indicated by the pump flow rate. RESULTS The CEBF was correlated to the true blood flow only for the posterior cortical ROI (R(2) = 0.45, p = 0.05). The normalization using arterial signals improved CEBF correlation to true blood flow: nCEBF became correlated to the true blood flow when considering all ROIs (R(2)= 0.94, p < 0.0001) and correlation was improved for both anterior and posterior cortical ROIs (R(2)= 0, 93, p = 0.0004; R(2)= 0, 90, p = 0.0005, respectively). However, a significant kidney-dependent effect was observed for the anterior cortical ROI (p = 0.017) but not for the posterior cortical ROI (p = 0.89). CONCLUSION Normalization using arterial signals significantly improved the estimation of blood flow calculated with CEUS.
Collapse
Affiliation(s)
- C Hoeffel
- Radiologie, Hôpital Robert Debré, Reims.
| | | | | | | | | | | | | |
Collapse
|
10
|
Michoux N, Huwart L, Abarca-Quinones J, Dorvillius M, Annet L, Peeters F, Van Beers BE. Transvascular and interstitial transport in rat hepatocellular carcinomas: dynamic contrast-enhanced MRI assessment with low- and high-molecular weight agents. J Magn Reson Imaging 2009; 28:906-14. [PMID: 18821616 DOI: 10.1002/jmri.21524] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
PURPOSE To assess which MRI-derived kinetic parameters reflect decreased transvascular and interstitial transport when low- and high-molecular-weight agents are used in rat hepatocellular carcinomas. MATERIALS AND METHODS Dynamic MRI after injection of a low-molecular-weight contrast agent of 0.56 kDa (Gd-DOTA, gadoterate) and two high-molecular-weight contrast agents of 6.47 kDa (P792, gadomelitol) and 52 kDa (P717, carboxymethyldextran Gd-DOTA) was performed in rats with chemically induced hepatocellular carcinomas. The data were analyzed with the Kety compartmental model, the extended Kety compartmental model in which it is assumed that the tissue voxels contain a vascular component, and the St Lawrence and Lee distributed-parameter model. RESULTS The extravascular extracellular space accessible to the contrast agent v(e) and the extraction fraction E decreased with increasing molecular weight of the contrast agent. In contrast, the volume transfer constant Ktrans did not differ significantly when low- or high-molecular-weight agents were used. CONCLUSION In this animal model the results suggest that the accessible extravascular extracellular space and the extraction fraction are more sensitive indicators of decreased transvascular and interstitial transport with high-molecular-weight agents than the volume transfer constant, which is a lumped representation of blood flow and permeability.
Collapse
Affiliation(s)
- Nicolas Michoux
- Diagnostic Radiology Unit, Université Catholique de Louvain, St-Luc University Hospital, Brussels, Belgium.
| | | | | | | | | | | | | |
Collapse
|
11
|
Huwart L, Sempoux C, Vicaut E, Salameh N, Annet L, Danse E, Peeters F, ter Beek LC, Rahier J, Sinkus R, Horsmans Y, Van Beers BE. Magnetic resonance elastography for the noninvasive staging of liver fibrosis. Gastroenterology 2008; 135:32-40. [PMID: 18471441 DOI: 10.1053/j.gastro.2008.03.076] [Citation(s) in RCA: 510] [Impact Index Per Article: 31.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2007] [Revised: 03/17/2008] [Accepted: 03/27/2008] [Indexed: 12/12/2022]
Abstract
BACKGROUND & AIMS The purpose of our study was to prospectively compare the success rate and diagnostic accuracy of magnetic resonance elastography, ultrasound elastography, and aspartate aminotransferase to platelets ratio index (APRI) measurements for the noninvasive staging of fibrosis in patients with chronic liver disease. METHODS We performed a prospective blind comparison of magnetic resonance elastography, ultrasound elastography, and APRI in a consecutive series of patients who underwent liver biopsy for chronic liver disease in a university-based hospital. Histopathologic staging of liver fibrosis according to the METAVIR scoring system served as the reference. RESULTS A total of 141 patients were assessed. The technical success rate of magnetic resonance elastography was higher than that of ultrasound elastography (133/141 [94%] vs 118/141 [84%]; P = .016). Magnetic and ultrasound elastography, APRI measurements, and histopathologic analysis of liver biopsy specimens were technically successful in 96 patients. The areas under the receiver operating characteristic curves of magnetic resonance elasticity (0.994 for F >or= 2; 0.985 for F >or= 3; 0.998 for F = 4) were larger (P < .05) than those of ultrasound elasticity, APRI, and the combination of ultrasound elasticity and APRI (0.837, 0.709, and 0.849 for F >or= 2; 0.906, 0.816, and 0.936 for F >or= 3; 0.930, 0.820, and 0.944 for F = 4, respectively). CONCLUSIONS Magnetic resonance elastography has a higher technical success rate than ultrasound elastography and a better diagnostic accuracy than ultrasound elastography and APRI for staging liver fibrosis.
Collapse
Affiliation(s)
- Laurent Huwart
- Diagnostic Radiology Unit, Université Catholique de Louvain, St-Luc University Hospital, Brussels, Belgium.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Huwart L, Salameh N, ter Beek L, Vicaut E, Peeters F, Sinkus R, Van Beers BE. MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging. Eur Radiol 2008; 18:2535-41. [PMID: 18504591 DOI: 10.1007/s00330-008-1051-5] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2007] [Revised: 04/07/2008] [Accepted: 04/19/2008] [Indexed: 12/28/2022]
Abstract
The purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR. The data acquisition time was about 20 min using spin-echo, and only 2 min using echo-planar imaging. The hepatic signal-to-noise ratios were similar on both images (22.51 +/- 5.37 for spin-echo versus 21.02 +/- 4.76 for echo-planar, p = 0.33). The elasticity measurements and the fibrosis stages were strongly correlated. The Spearman correlation coefficients were r = 0.91 (p < 0.01) with spin-echo and r = 0.84 (p < 0.01) with echo-planar sequences. These correlation coefficients did not differ significantly (p = 0.17). A strong correlation was also observed between spin-echo and echo-planar elasticity (r = 0.83, p < 0.001), without systematic bias. The results of our study showed that echo-planar imaging substantially decreased the data acquisition time of MR elastography, while maintaining the image quality and diagnostic performance for staging of liver fibrosis. This suggests that echo-planar MR elastography could replace spin-echo MR elastography in clinical practice.
Collapse
Affiliation(s)
- Laurent Huwart
- Diagnostic Radiology Unit, Université Catholique de Louvain, St-Luc University Hospital, Brussels, Belgium
| | | | | | | | | | | | | |
Collapse
|
13
|
Neves F, Huwart L, Jourdan G, Reizine D, Herman P, Vicaut E, Guichard JP. Head and neck paragangliomas: value of contrast-enhanced 3D MR angiography. AJNR Am J Neuroradiol 2008; 29:883-9. [PMID: 18339724 DOI: 10.3174/ajnr.a0948] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE A rapid and accurate MR imaging technique would be beneficial to assess paragangliomas in the head and neck and to distinguish them from other lesions. The purpose of this study was to determine whether the combination of elliptic centric contrast-enhanced MR angiography (CE-MRA) and unenhanced and enhanced spin-echo imaging (conventional MR imaging) is more accurate than conventional MR imaging alone to assess paragangliomas in the head and neck. MATERIALS AND METHODS Three radiologists retrospectively and independently reviewed CE-MRA and conventional MR imaging in 27 patients with suspected paragangliomas. The overall image quality and the probability of paraganglioma were recorded. The results of each technique and their combination were analyzed for sensitivity and specificity. Receiver operating characteristic (ROC) analyses were performed by using histologic analysis, imaging, and/or clinical findings as the reference standard. RESULTS Forty-six lesions were found in 27 patients. In the assessment of paragangliomas, the combination of conventional MR imaging and CE-MRA was significantly superior to conventional MR imaging alone. Sensitivity and specificity respectively were the following: for CE-MRA, 100% and 94%; and for conventional MR imaging, 94% and 41%. The specificity of CE-MRA was significantly higher than that of conventional MR imaging (P = .004). There was good-to-excellent interobserver agreement for the paraganglioma probability with CE-MRA (nonweighted kappa, 0.67-0.77), whereas there was fair-to-good interobserver agreement with conventional MR imaging (nonweighted kappa, 0.50-0.65). CONCLUSION In combination with conventional MR imaging, CE-MRA yields an excellent diagnostic value for the assessment of head and neck paragangliomas; hence, the 2 techniques should be regarded as complementary.
Collapse
Affiliation(s)
- F Neves
- Department of Neuroradiology, Groupe Hospitalier Lariboisière-Fernand-Widal AP-HP, Paris, France
| | | | | | | | | | | | | |
Collapse
|
14
|
Huwart L, Sempoux C, Salameh N, Jamart J, Annet L, Sinkus R, Peeters F, ter Beek LC, Horsmans Y, Van Beers BE. Liver fibrosis: noninvasive assessment with MR elastography versus aspartate aminotransferase-to-platelet ratio index. Radiology 2007; 245:458-66. [PMID: 17940304 DOI: 10.1148/radiol.2452061673] [Citation(s) in RCA: 324] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE To prospectively compare the sensitivity and specificity of magnetic resonance (MR) elastography with those of the routinely available aspartate aminotransferase-to-platelet ratio index (APRI) test for staging hepatic fibrosis in patients who have undergone liver biopsy for suspicion of chronic liver disease, with histopathologic examination as the reference standard. MATERIALS AND METHODS The study was approved by the ethics committee. All patients gave written informed consent. Eighty-eight patients (37 men, 51 women; mean age, 54.0 years +/- 13.1 [standard deviation]) who underwent liver biopsy for suspicion of chronic liver disease underwent MR elastography and APRI testing within 2 days after liver biopsy. At histopathologic examination, the fibrosis stage was assessed according to METAVIR scores (fibrosis scores F0 [no fibrosis] to F4 [cirrhosis]). MR elastography was performed by transmitting mechanical waves within the liver and measuring the small cyclic displacement of the liver spins with a phase-contrast spin-echo sequence. The performances of MR elastography and APRI testing were assessed, and the optimal cutoff values for fibrosis stage were determined with receiver operating characteristic (ROC) curve analysis. RESULTS At MR elastography, areas under the ROC curves (A(z)) for elasticity and viscosity, respectively, were 0.999 and 0.863 at fibrosis scores greater than or equal to F2, 0.997 and 0.962 at scores greater than or equal to F3, and 1.000 and 0.986 at score F4. A(z) values for elasticity at MR were significantly larger than those for the APRI (0.854 at scores > or = F2, P < .001; 0.886 at scores > or = F3, P = .003; and 0.851 at score F4, P = .004). Optimal cutoff values of elasticity were 2.5 kPa for fibrosis scores greater than or equal to F2, 3.1 kPa for scores greater than or equal to F3, and 4.3 kPa for score F4. CONCLUSION Large A(z) values for elasticity (>0.990 for scores > or = F2, > or = F3, and F4) show that MR elastography was accurate in liver fibrosis staging and superior to biochemical testing with APRIs.
Collapse
Affiliation(s)
- Laurent Huwart
- Diagnostic Radiology Unit, Department of Pathology, and Laboratory of Gastroenterology, Université Catholique de Louvain, St-Luc University Hospital, B-1200, Brussels, Belgium.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Huwart L, Michoux N, Van Beers B. Magnetic resonance imaging of angiogenesis in tumors. Clin Imaging 2007. [DOI: 10.1016/j.clinimag.2007.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
16
|
Abstract
Tumor angiogenesis induces the proliferation of immature blood vessels that are both heterogeneous and leaky. These characteristics can be demonstrated by measuring the perfusion parameters with MRI. Perfusion MRI is usually performed with in T1-weighted dynamic imaging after bolus injection of an exogenous contrast agent such as gadolinium chelate. The perfusion parameters are obtained by semi-quantitative or quantitative analysis of the enhancement curves in the tumor and the arterial input. Perfusion can also be assessed without injecting a contrast agent using arterial spin labeling techniques, diffusion MRI, or BOLD (blood oxygen level dependent) MRI. However, these latter methods are limited by a low signal-to-noise ratio and problems with quantification. The main indication for perfusion MRI is the assessment of antiangiogenic and antivascular treatments. New possibilities for demonstrating angiogenic blood vessels are being opened by molecular imaging.
Collapse
Affiliation(s)
- L Huwart
- Unité de Radiodiagnostic, Université Catholique de Louvain, Cliniques Universitaires St-Luc, Bruxelles, Belgique
| | | | | |
Collapse
|
17
|
Huwart L, El Khoury M, Lesavre A, Phan C, Rangheard AS, Bessoud B, Menu Y. Quelle est l’épaisseur de l’appendice normal au scanner multibarrette ? ACTA ACUST UNITED AC 2007; 88:385-9. [PMID: 17457270 DOI: 10.1016/s0221-0363(07)89835-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To determine the wall thickness and external diameter values of the normal appendix on multidetector computed tomography (MDCT). Materials and methods. A senior radiologist with no knowledge of the patient's surgical history prospectively examined the abdominal-pelvic CT scans of 57 consecutive adult patients with no suspicion for appendicitis. Most of the patients (50/57) received an intravenous iodinated contrast material injection, but none had gastrointestinal studies. All slices (1 and 5 mm) and multiplanar reconstructions were analyzed on a treatment console. The external diameter of the appendix, the thickness of the two appendicular walls, and the presence or absence of intraluminal gas were noted. RESULTS The appendix was visualized in 82% of the cases (47/57). The mean external diameter was 6.7 mm+/-1.2 (range, 5.0-11.0 mm). The mean thickness of the two walls was 4.8 mm+/-1.0 (range, 2.6-6.4 mm). Intraluminal air was visualized in 87% of cases (41/47). CONCLUSION Contrary to external diameter, the normal thickness of the appendix's two walls does not go beyond the threshold of 6 mm and therefore seems to be a reliable measurement for identifying a normal appendix using MDCT.
Collapse
Affiliation(s)
- L Huwart
- Service de Radiologie, Hôpital de Bicêtre, 78 Rue du Général Leclerc 94275 Le Kremlin Bicêtre Cedex, France.
| | | | | | | | | | | | | |
Collapse
|
18
|
Huwart L, El Khoury M, Lesavre A, Phan C, Rangheard AS, Bessoud B, Menu Y. [Is appendicolith a reliable sign for acute appendicitis at MDCT?]. ACTA ACUST UNITED AC 2006; 87:383-7. [PMID: 16691166 DOI: 10.1016/s0221-0363(06)74017-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To determine the frequency of detection of appendicoliths on normal appendix at multidetector row computed tomography (MDCT) with multiplanar reconstructions (MPR). MATERIALS AND METHODS A senior radiologist, blinded to patient's surgical history, prospectively and independently reviewed abdominopelvic MDCT scans in 57 consecutive adult patients without symptoms suggesting appendicitis. Most patients had IV iodine injection, but no oral contrast. Thick (5 mm) and thin (1 mm) slices were analyzed on a workstation. MPR were available. Localization of the appendix, overall diameter, intraluminal gas and appendicolith were recorded. RESULTS The appendix was visualized in 47/57 (82%). An appendicolith was found in 13%. Intraluminal gas was identified in 87%. The localization was retrocaecal (47%), mediocaecal (21%) or pelvic (32%). The mean overall diameter of the normal appendix was 6.7 mm +/- 1.2 (SD). CONCLUSION Appendicolith was found in a significant number of normal patients at MDCT and don't represent a specific sign for appendicitis.
Collapse
Affiliation(s)
- L Huwart
- Service de Radiologie, Hôpital de Bicêtre, 78 rue du Général Leclerc 94275 Le Kremlin Bicêtre cedex.
| | | | | | | | | | | | | |
Collapse
|
19
|
Huwart L, Peeters F, Sinkus R, Annet L, Salameh N, ter Beek LC, Horsmans Y, Van Beers BE. Liver fibrosis: non-invasive assessment with MR elastography. NMR Biomed 2006; 19:173-9. [PMID: 16521091 DOI: 10.1002/nbm.1030] [Citation(s) in RCA: 231] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The aim of this study was to assess the feasibility of using non-invasive MR elastography for determining the stage of liver fibrosis. Twenty-five consecutive patients who had liver biopsy for suspicion of chronic liver disease were included in the study. The stage of fibrosis on the biopsies was assessed according to the METAVIR scoring system from F0, no fibrosis, to F4, cirrhosis. MR elastography was performed by transmitting low-frequency (65 Hz) mechanical waves into the liver with a transducer placed at the back of the patients. The MR pulse sequence was a motion-sensitized spin-echo sequence, phase-locked to the mechanical excitation. The phase maps were processed to obtain shear elasticity and shear viscosity maps. The mean hepatic shear elasticity increased with increasing stage of fibrosis. The mean elasticity was 2.24 +/- 0.23 kPa in the 11 patients without substantial fibrosis (F0-F1 grades), 2.56 +/- 0.24 kPa in the four patients with substantial fibrosis (F2-F3) and 4.68 +/- 1.61 kPa in the 10 patients with cirrhosis (F4). The differences between groups were statistically significant (p <or= 0.05). The mean shear viscosity was significantly higher in the patients with cirrhosis (5.19 +/- 1.85 Pa x s) than in the patients without cirrhosis (2.39 +/- 0.86 Pa x s in F0-F1 and 2.27 +/- 0.38 Pa x s in F2-F3 patients). It is concluded that non-invasive MR elastography is a feasible method to assess the stage of liver fibrosis.
Collapse
Affiliation(s)
- Laurent Huwart
- Diagnostic Radiology Unit, Université Catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | | | | | |
Collapse
|