1
|
Toma FR, Moleriu LC, Porojan L. Micro-CT Marginal and Internal Fit Evaluation of CAD/CAM High-Performance Polymer Onlay Restorations. Polymers (Basel) 2023; 15:polym15071715. [PMID: 37050329 PMCID: PMC10096728 DOI: 10.3390/polym15071715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 03/20/2023] [Accepted: 03/27/2023] [Indexed: 04/14/2023] Open
Abstract
(1) Background: The use of high-performance polymers for fixed restorations requires additional studies regarding their adaptability and processing with CAD/CAM technology. This in vitro study aims to assess the marginal and internal fit of PEEK and PEKK materials using microcomputed tomography. (2) Methods: Twenty-four (n = 8) MOD onlays made of PEKK (Pekkton ivory), unmodified PEEK (Juvora medical), and modified PEEK (BioHPP) were investigated. A typodont mandibular left first molar was scanned to achieve 24 resin, 3D printed abutment teeth. The onlays were fabricated with a five-axis milling machine, and after cementation of the specimens, the marginal (MG) and internal gaps (IG) were evaluated at twelve points in the mesio-distal section and thirteen points in the bucco-lingual section using microcomputed tomography. For statistical data analysis, Wilcoxon signed-rank/paired Student t-Test, Mann-Whitney/unpaired Student t-Test, and one-way ANOVA test were applied. (3) Results: Significant differences (p < 0.05; α = 0.05) were reported between the MG and IG for each material for all three polymers and also among two materials in terms of the MG and IG (except Juvora-BioHPP). The highest IG values were recorded in angular areas (axio-gingival line angle) in the mesio-distal section for all the polymers. (4) Conclusions: For all the materials, MG < IG. The type of polymer influenced the adaptability; the lowest marginal and internal gap mean values were recorded for BioHPP. The analyzed polymer used for onlays are clinically acceptable in terms of adaptability.
Collapse
Affiliation(s)
- Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Lavinia Cristina Moleriu
- Department of Functional Science, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, "Victor Babeș" University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| |
Collapse
|
2
|
Porojan L, Toma FR, Bîrdeanu MI, Vasiliu RD, Matichescu A. Topographical and Optical Characteristics of Thermoplastic Dental Appliances Materials Related to Water Sorption. J Funct Biomater 2023; 14:jfb14040190. [PMID: 37103280 PMCID: PMC10146702 DOI: 10.3390/jfb14040190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 03/22/2023] [Accepted: 03/27/2023] [Indexed: 03/31/2023] Open
Abstract
Clear thermoplastic materials have increased in popularity in the dental field due to their various applications, combination of excellent aesthetics, and good biomechanical behavior, but they may be influenced by different environmental conditions. The purpose of the present study was to assess the topographical and optical characteristics of thermoplastic dental appliances materials relative to water sorption. PET-G polyester thermoplastic materials were evaluated in this study. Related to water uptake and desiccation stages, surface roughness was analyzed, and three-dimensional AFM profiles were generated for nano-roughness measurements. Optical CIE L*a*b* coordinates were recorded and parameters like translucency (TP), contrast ratio for the opacity (CR), and opalescence (OP) were derived. Levels of color changes were achieved. Statistical analyses were performed. Water uptake significantly increases the specific weight of the materials, and after desiccation, the mass decreases. Roughness increased after water immersion as well. Regression coefficients indicated a positive correlation between TP and a* and between OP and b*. Studied PET-G materials have a different behavior to water exposure, but for all their specific weight, they increased significantly within the first 12 h. It is accompanied by an increase in the roughness values, even if they continue to be kept below the critical mean surface roughness. On nano-level, 3D images show an increase in inhomogeneity in the network structure of particles. Slight color changes were registered.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
- Correspondence:
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, A. Păunescu Podeanu Str. No. 144, 300569 Timisoara, Romania
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timisoara, Eftimie Murgu Square No. 2, 300041 Timisoara, Romania
| |
Collapse
|
3
|
Toma FR, Porojan SD, Vasiliu RD, Porojan L. The Effect of Polishing, Glazing, and Aging on Optical Characteristics of Multi-Layered Dental Zirconia with Different Degrees of Translucency. J Funct Biomater 2023; 14:jfb14020068. [PMID: 36826868 PMCID: PMC9967825 DOI: 10.3390/jfb14020068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/14/2023] [Accepted: 01/24/2023] [Indexed: 02/01/2023] Open
Abstract
(1) Background: Considering that the appearance of a dental material is an important factor that contributes to the success of prosthetic restorations. The purpose of this study is to investigate the optical properties and color changes among the layers of three commercial zirconias, to compare the aspect of the polished and glazed surfaces before and after aging and to evaluate the effects of hydrothermal degradation on their aesthetics. (2) Methods: Forty-eight plate-shaped samples were sectioned from presintered blocks of each multilayer translucent zirconia with different Yttrium content: Ceramill Zolid fx ML (5 mol%) = CeZ, STML (4 mol%) = STM, IPS e.maxZirCAD CEREC/in Lab MT Multi (4 mol% + 5 mol%) = IPZ. The samples were sintered according to the recommendation of each manufacturer, and half (24) of them were polished and the other half (24) glazed on one of the surfaces. Each type was equally divided into one control and one aging group, and, for each material, this resulted in four groups (n = 12): polished-control, polished-autoclaved glazed-control, and glazed-autoclaved. The artificial aging was carried out with an autoclave and distilled water at 134 °C, 0.2 MPa for 1 h, and for optical parameters (TP, CR, OP) and color change (ΔE*) measurements on a black and white background in a CIE L*a*b* color system, a spectrophotometer was used. The specimens were evaluated in incisal, cervical, and medium areas on polished and glazed samples before and after the aging stage. Statistical analysis was achieved with a two-way ANOVA test, the unpaired t-test, and the paired t-test. (3) Results: Before and after aging, the mean TP values for polished samples were higher than the glazed ones. After aging, the mean TP values increased for all groups (except polished CeZ), and significant differences were reported for polished STM, IPZ. After LTD, the opalescence registered an increase for almost all groups (except polished CeZ, polished and glazed IPZ-medium area), and significant differences were reported for almost all groups (except STM-incisal, IPZ-cervical, medium areas). The levels of color change were between extremely slight to perceivable. (4) Conclusions: Optical properties of the selected multilayer zirconia were influenced by polishing and glazing as surface treatment and affected by artificial aging (CeZ the least); perceivable color changes for polished STM, IPZ were detected.
Collapse
Affiliation(s)
- Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Sorin Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timisoara, Romania
- Correspondence:
| |
Collapse
|
4
|
Porojan L, Toma FR, Bîrdeanu MI, Vasiliu RD, Uțu ID, Matichescu A. Surface Characteristics and Color Stability of Dental PEEK Related to Water Saturation and Thermal Cycling. Polymers (Basel) 2022; 14:polym14112144. [PMID: 35683817 PMCID: PMC9183185 DOI: 10.3390/polym14112144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 05/15/2022] [Accepted: 05/23/2022] [Indexed: 12/10/2022] Open
Abstract
(1) Background: The study was undertaken to evaluate the surface characteristics, microhardness, and color stability of PEEK materials related to water saturation and in vitro aging. (2) Methods: Custom specimens of unmodified and modified PEEK CAD/CAM materials were investigated: BioHPP, a ceramic reinforced PEEK, and Finoframe PEEK and Juvora medical PEEK, 100% PEEK materials. Forty-eight plates were sectioned in rectangular slices. The specimens were immersed in distilled water at 37 °C for a period of 28 days, and then subjected to aging by thermal cycling (10,000 cycles). Surface roughness was measured with a contact profilometer; nanosurface topographic characterization was made by Atomic Force Microscopy; Vickers hardness measurements were performed with a micro-hardness tester; color changes were calculated. All registrations were made before immersion in water and then subsequently once a week for 4 weeks, and after thermocycling. (3) Results: The studied reinforced and unfilled PEEK materials reached water saturation after the first week of immersion, without significant differences between them. The most affected from this point of view was the reinforced PEEK material. Thermocycling induces a significant increase inmicroroughness, without significant differences between the studied materials. In relation to the nanosurface topography and roughness, the reinforced PEEK material was the least modified by aging. The color changes after 4 weeks of water immersion and one year of simulated in vitro aging ranged from extremely slight to slight, for all materials. (4) Conclusions: Water absorption was associated with a decrease in microhardness. Surface characteristics are affected by water immersion and thermocycling. Perceivable or marked color changes of the materials were not detected during the study.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
- Correspondence:
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babeș University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania; (F.R.T.); (R.D.V.)
| | - Ion-Dragoș Uțu
- Department of Materials and Fabrication Engineering, Politehnica University Timişoara, Bulevard MihaiViteazul nr.1, 300222 Timişoara, Romania;
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, Victor Babes University of Medicine and Pharmacy Timișoara, Eftimie Murgu Square No. 2, 300041 Timișoara, Romania;
| |
Collapse
|
5
|
Toma FR, Bîrdeanu MI, Uțu ID, Vasiliu RD, Moleriu LC, Porojan L. Surface Characteristics of High Translucent Multilayered Dental Zirconia Related to Aging. Materials (Basel) 2022; 15:3606. [PMID: 35629636 PMCID: PMC9144863 DOI: 10.3390/ma15103606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 05/13/2022] [Accepted: 05/16/2022] [Indexed: 02/06/2023]
Abstract
(1) Background: The purpose of this study was to evaluate the differences in terms of surface characteristics (roughness, topography, microhardness) among layers for multi-layered high translucent and super-high translucent zirconia and the influence of finishing and aging on surface characteristics and microstructure. (2) Methods: Three types of translucent multilayer zirconia were evaluated: STML (4Y-TZP); IPS e.maxZirCAD CEREC/in Lab MT Multi (4Y-TZP + 5Y-TZP); CeramillZolidfx ML (5Y-TZP). Ninety-six plate-shaped samples (32 for a material), 16 mm × 14 mm × 1 mm size, were cut with a precision disc, polished on both sides with sand papers and sintered respecting the manufacturer’s protocol. Half of the specimens (16) were finished by polishing and the other half by glazing and then equally divided into one control group and one group subject to aging by autoclaving (1 h, 134 °C, 0.2 MPa), resulting in four groups of eight samples, for each zirconia. The specimens were evaluated in three areas: cervical, medium, incisal-of each glazed or polished surface, before and after aging. Tests were performed to determine the surface roughness using a profilometer; the surface topography by an atomic force microscope (AFM) and a scanning electron microscope (SEM). Microhardness was recorded using a microhardness tester. Statistical analyses were performed using two-way ANOVA test, unpaired sample t-Test, paired sample t-Test (α = 0.05) and Pearson’s correlation. (3) Results: Before and after autoclaving, for glazed samples significance (p < 0.05) higher surface roughness, respectively lower microhardness in comparison with the polished group was assessed. No significant differences (p > 0.05) were reported between the three areas, on glazed or polished surfaces of a material. Although, after aging an increase in surface roughness was observed both on glazed and polished samples, statistical differences were found for STML (p < 0.05). No significant differences (p> 0.05) concerning microhardness among the same areas, on glazed and polished surfaces, recorded before and after aging, except CeramillZolidfx ML glazed samples. (4) Conclusions: For tested zirconia materials no significant differences among layers were registered regarding surface characteristics. Surface treatment (glazing or polishing) has a significant impact on surface roughness and microhardness. Both before and after aging, the surface roughness values for the glazed samples were higher than for those polished. The super translucent 4Y-TZP material was more affected by aging compared to the super-high translucent 5Y-TZP material. The combined material revealed similarities for each layer corresponding to the microstructure.
Collapse
Affiliation(s)
- Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Mihaela Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Ion-Dragoș Uțu
- Department of Materials and Fabrication Engineering, Politehnica University Timişoara, Bd. Mihai Viteazu nr.1, 300222 Timisoara, Romania;
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| | - Lavinia Cristina Moleriu
- Department of Functional Science, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania;
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, EftimieMurgu Sq. No. 2, 300041 Timisoara, Romania; (F.R.T.); (R.D.V.)
| |
Collapse
|
6
|
Porojan L, Toma FR, Vasiliu RD, Topală FI, Porojan SD, Matichescu A. Optical Properties and Color Stability of Dental PEEK Related to Artificial Ageing and Staining. Polymers (Basel) 2021; 13:polym13234102. [PMID: 34883606 PMCID: PMC8658820 DOI: 10.3390/polym13234102] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 11/20/2021] [Accepted: 11/21/2021] [Indexed: 12/11/2022] Open
Abstract
Considering that the processes of PEEK discoloration caused by either intrinsic or extrinsic factors require elucidation, the aim of this study was to investigate the long-term effect of the combined action of ageing and immersing solutions on the optical properties and color stability of PEEK material, related to surface processing (polishing or glazing). (2) Methods: This study aims to determine the influence of different ageing and staining protocols on optical properties, color changes, and surface roughness of a reinforced PEEK material (bioHPP, Bredent, Senden, Germany). For ageing, specimens were submitted to 5000 cycles in a 55 °C bath and a 5 °C bath filled with distilled water. For staining, thermal cycling was performed in a hot coffee bath (55 °C) and a bath filled with distilled water (37 °C) and in a cold juice bath (5 °C) and a bath filled with distilled water (37 °C). Translucency (TP) and opalescence (OP) parameters were determined, the total color change value (ΔΕ*) was calculated, specimens’ surface roughness was analyzed, and statistical analyses were performed. (3) Results: The mean TP values of the studied samples were in the interval of 1.25–3.60, which is lower than those reported for natural teeth or other aesthetic restoration materials. The OP values of PEEK were registered in the range of 0.27–0.75, being also lower than those of natural teeth or other aesthetic restoration materials. OP has a very strong positive relationship with TP. The mean registered Ra values for all subgroups were below 0.13 µm. Artificial ageing and staining in hot coffee proved to increase the roughness values. (4) Conclusions: The glazing of PEEK has a favorable effect on surface roughness and opalescence, irrespective of the artificial ageing or staining protocols. Artificial ageing damages the color stability and roughness of PEEK, regardless of surface processing, and decreases the translucency and opalescence of glazed surfaces. Immersion in hot coffee leads to perceivable discolorations.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
| | - Flavia Roxana Toma
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
| | - Roxana Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania; (L.P.); (F.R.T.)
- Correspondence:
| | - Florin-Ionel Topală
- Department of Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Sorin Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), Center for Advanced Technologies in Dental Prosthodontics, Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Anamaria Matichescu
- Department of Preventive, Community Dentistry and Oral Health, Faculty of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy Timișoara, 14A Tudor Vladimirescu Ave., 300173 Timisoara, Romania;
| |
Collapse
|
7
|
Vasiliu RD, Porojan SD, Porojan L. In Vitro Study of Comparative Evaluation of Marginal and Internal Fit between Heat-Pressed and CAD-CAM Monolithic Glass-Ceramic Restorations after Thermal Aging. Materials (Basel) 2020; 13:E4239. [PMID: 32977603 PMCID: PMC7579449 DOI: 10.3390/ma13194239] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 09/16/2020] [Accepted: 09/21/2020] [Indexed: 11/17/2022]
Abstract
The accuracy of newly developed ceramic materials is still being studied. Marginal and internal adaptation are known factors that have an essential impact on the long term success of dental restorations. The aim of this in vitro study was to evaluate the marginal and internal fit of heat-pressed and milled monolithic glass-ceramic restorations based on their ceramic type, processing technique, and in vitro thermocycling. Thirty-two crowns were studied and divided into four groups (n = 8), according to the ceramic material (feldspathic glass-ceramic (F) and zirconia reinforced lithium silicate glass-ceramic (ZLS)) and to their technological obtaining processes (milling (M) and heat-pressing (P)). A typodont preparation was scanned with a D2000 3D scanner to obtain identical 32 resin 3D-printed abutment teeth. Marginal and internal gaps were measured using the silicone replica technique under 40× magnification. The crowns were further cemented and thermally aged for 10,000 cycles After cementation and thermocycling of the samples, marginal and internal gaps were assessed using micro-CT (micro-computed tomography)) analysis. Data were statistically analyzed using statistical tests. Significant differences were found before and after cementation and thermocycling among the tested materials (p < 0.05). Related to technological processing, significant differences were seen in the marginal area between FP and FM (p < 0.05) Significant differences were also found in the axial and occlusal areas between the ZLSP and ZLSM. Thermocycling and cementation did not have a significant effect on the tested materials (p < 0.05). The technological processes influenced the marginal and internal fit of the crowns in favor of the CAD/CAM (computer aided design/computer aided manufacturing)technologies. Thermal aging had little effect on marginal adaptability; it increased the values for all the tested samples in a small way, but the values remained in their clinically acceptable range for all of the crowns.
Collapse
Affiliation(s)
- Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), University of Medicine and Pharmacy “Victor Babes”, Eftimie Murgu Sq. no. 2, 300041 Timisoara, Romania;
| | - Sorin Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), University of Medicine and Pharmacy “Victor Babes”, Eftimie Murgu Sq. no. 2, 300041 Timisoara, Romania;
| | - Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), University of Medicine and Pharmacy “Victor Babes”, Eftimie Murgu Sq. no. 2, 300041 Timisoara, Romania;
| |
Collapse
|
8
|
Porojan L, Vasiliu RD, Porojan SD, Bîrdeanu MI. Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents. Polymers (Basel) 2020; 12:polym12081736. [PMID: 32756439 PMCID: PMC7464035 DOI: 10.3390/polym12081736] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 07/30/2020] [Accepted: 08/01/2020] [Indexed: 01/04/2023] Open
Abstract
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| |
Collapse
|
9
|
Porojan L, Vasiliu RD, Bîrdeanu MI, Porojan SD. Surface Characterization and Optical Properties of Reinforced Dental Glass-Ceramics Related to Artificial Aging. Molecules 2020; 25:molecules25153407. [PMID: 32731378 PMCID: PMC7435760 DOI: 10.3390/molecules25153407] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 07/24/2020] [Accepted: 07/26/2020] [Indexed: 11/16/2022] Open
Abstract
The development of various dental glass-ceramic materials and the evolution of novel processing technologies lead to an essential change in the clinical and technical workflow. The long-term success of a dental restoration treatment is defined by its durability, which is directly influenced by the oral environment. This study's purpose was to evaluate the artificial aging behavior of nanostructured, respective microstructured ceramics related to surface topography, roughness, and optical properties. Six monolithic restoration materials were selected: milled lithium disilicate glass-ceramic (LDS-M) MT (medium translucency), hot-pressed lithium disilicate glass-ceramic (LDS-P) MT and HT (high translucency), milled zirconia-reinforced lithium silicate ceramic (ZLS-M) MT and hot-pressed zirconia-reinforced lithium silicate ceramic (ZLS-P) MT and HT, resulting n = 96 surfaces. All the samples were artificially aged by thermal cycling, and all investigations were made before and after thermal cycling. In terms of optical properties, differences recorded between ZLS and LDS ceramics are not significant. Thermal cycling increases the translucency of ZLS and LDS glass-ceramic materials significantly, with the most harmful effect on the pressed and polished samples. Micro- and nano roughness are significantly influenced by in vitro aging and a negative correlation was recorded. Glazed samples are characterized by significant rougher surfaces for all types of materials. On nanolevel, ZLS materials are significantly smoothed by thermal cycling.
Collapse
Affiliation(s)
- Liliana Porojan
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| | - Roxana-Diana Vasiliu
- Department of Dental Prostheses Technology (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
- Correspondence: ; Tel.: +40-745225523
| | - Mihaela-Ionela Bîrdeanu
- National Institute for Research and Development in Electrochemistry and Condensed Matter, 300569 Timisoara, Romania;
| | - Sorin-Daniel Porojan
- Department of Oral Rehabilitation (Dental Technology), “Victor Babeș” University of Medicine and Pharmacy Timișoara, Romania, Eftimie Murgu Sq. no. 2, 300041 Timișoara, Romania;
| |
Collapse
|
10
|
Porojan L, Birdeanu M, Porojan S. Multidisciplinary Approach on the Corrosion Behavior of Welded Nickel-free and Nickel-containing Stainless Steel Orthodontic Wires. Rev Chim 2019. [DOI: 10.37358/rc.19.7.7359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The oral environment is responsible to the degradation of metal wires, with consequent release of metal ions in the oral cavity during corrosion, and welded joints are known as areas that are particularly susceptible to corrosion. The aim of the study was to achieve the corrosion behavior of welded Ni-free and Ni-containing stainless steel (SS) orthodontic wires. The morphology and the topography of the laser welded samples were investigated by scanning electron microscopy and atomic force microscopy. The electrochemical measurements calculated the values for corrosion potential, corrosion current and corrosion rate, for different pH values. Immersion in acidic solution had minimal effect on the corrosion on the joint regions. Ni-free SS wires proved to have a better corrosion resistance, improved by laser welding. Ni-containing SS wires are positive influenced by laser welding, relative to the corrosion behavior.
Collapse
|
11
|
Szuhanek C, Golban DM, Negru R, Negrutiu ML, Marsavina L, Duma VF, Sinescu C, Porojan L. Flash-Free Orthodontic Adhesive System Compared with the Conventional Direct Bonding Method. Rev Chim 2018. [DOI: 10.37358/rc.18.11.6709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The latest technology in the field of orthodontic materials is represented by the Flash-Free Orthodontic Adhesive System. In the present study this novel technique is compared with the conventional direct bonding method. Ten extracted human premolars were separated into two groups: in the Group 1, APC Flash-Free Adhesive Coated Appliance System (3M Unitek, Monrovia, CA, USA) was bonded, while in the control Group 2, Clarity Advanced braces (3M Unitek, Monrovia, CA, USA) were bonded using XT Adhesive Paste (3M Unitek, Monrovia, CA, USA) applied by the clinician on the bracket base. Bonding times were recorded for each sample. Shear bond strength (SBS) was recorded using Zwick Zoel Z005. After debonding, the adhesive remnant index (ARI) was established for both groups. Group 1 showed a mean bonding time of 21 s, while Group 2 needed about 45 s for each bracket bonding. Both groups had clinically accepted SBS values, but the difference between them was significant (10.97 MPa versus 8.23 MPa). ARI scores were equal to 1 for most samples. In conclusion, reducing the time for bracket placing, APC Flash-Free Coated Appliance System showed a brackets bonding time reduced to half compared to the conventional technique. This aspect, combined with significantly higher SBS values, makes this novel system better than the classical one. For both groups, more than half of the adhesive remained on the bracket base, which facilitates cleaning after debonding.
Collapse
|
12
|
Dan ML, Costea LV, Savencu CE, Porojan L. Influence of pH on the Corrosion Behaviour of Laser-Processed Co-Cr Dental Alloys in Artificial Saliva. ACTA ACUST UNITED AC 2018. [DOI: 10.1088/1757-899x/416/1/012036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Savencu CE, Porojan S, Porojan L. Analysis of Internal and Marginal fit of Metal-ceramic Crowns During Processing, Using Conventional and Digitized Technologies. Rev Chim 2018. [DOI: 10.37358/rc.18.7.6398] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Copings accuracy is an important factor for long-term clinical success of ceramic fused to metal dental restorations. The purpose of the study was to investigate marginal and internal fit of metal-ceramic crowns during processing, using conventional and digitized technologies. Metal copings were produced by Digital light Processing (DLP), invested and casted. Ceramic veneers were overpressed. Internal and marginal fit was measured using silicon replica technique for patterns, casted frameworks and final ceramic fused to metal crowns. Best adaptation was found in resin-pattern group, with small increasing of gap after casting and after ceramic pressing.
Collapse
|
14
|
Porojan L, Birdeanu M, Savencu C, Porojan S. Surface Characteristics and Corrosion Properties of Co-Cr Dental Alloys Processed by Laser-based Methods. Rev Chim 2017. [DOI: 10.37358/rc.17.11.5923] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Technological developments have led to the implementation of novel digitalized manufacturing methods for the production of metallic structures in prosthetic dentistry, less studied to date. The objective of the study was to assess the morphological characteristics and corrosion properties of selective laser sintered (SLS) and selective laser melted (SLM) cobalt�chromium (Co�Cr) dental alloys related to the surface processing and pH variations. For the experimental analyses metallic specimens made of Co-Cr dental alloys were prepared using SLS and SLM, as indicated by the manufacturers. The morphology and the topography of the samples were investigated by scanning electron microscopy and atomic force microscopy. Electrochemical measurements were made and the values for corrosion potential (Ecorr), corrosion current (icorr) and corrosion rate were calculated. The immanent advantages of additive technologies are accompanied by porosities resulted after the deposition of the fine metallic powder, especially for the SLM method. Considering the corrosion current density value a parameter which provides information on the kinetics of the corrosion process, SLS samples showed better performance under pH variations. Surface processing can result in an improvement in the corrosion performance also for extreme pH values. Given that the microstructure and corrosion behavior was significantly different, further differences in the clinical behavior of prosthetic restorations manufactured using SLS and SLM additive techniques are anticipated.
Collapse
|