1
|
Motta LM, Manchado I, Blanco G, Quintana-Montesdeoca MP, Garcés L, Garcés GL. Cross-cultural adaptation and validation of a Spanish version of the self-administered foot evaluation questionnaire (SAFE-Q). J Orthop Sci 2024; 29:627-631. [PMID: 36914484 DOI: 10.1016/j.jos.2023.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/11/2023] [Accepted: 02/14/2023] [Indexed: 03/16/2023]
Abstract
BACKGROUND The self-administered foot evaluation questionnaire is a comprehensive measure for assessing the perception of patients regarding their foot-related problems. However, it is currently only available in English and Japanesse. Therefore, this study aimed to cross-culturally adapt the questionnaire to Spanish and assess its psychometric properties. METHODS The methodology recommended by the International Society for Pharmaco Economics and Outcomes Research for translating and validating patient-reported outcome measures was followed for the Spanish translation. After a pilot study with 10 patients and 10 controls, an observational study was carried out between March and December 2021. The Spanish version of the questionnaire was filled by 100 patients with unilateral foot disorders, and the time spent to complete each questionnaire was recorded. Cronbach's alpha was calculated to analyze the internal consistency of the scale and Pearson's correlation coefficients for the degree of inter-subscale associations. RESULTS The maximum correlation coefficient for the Physical Functioning, Daily Living, and Social Functioning subscales was 0.768. The inter-subscale correlation coefficients were significant (p < 0.001). Additionally, the value of Cronbach's alpha for the whole scale was 0.894 (95% confidence interval, 0.858-0.924). The values of Cronbach's alpha varied between 0.863 and 0.889 when the value of one of the five subscales was suppressed, which can be considered a measure of good internal consistency. CONCLUSION The Spanish version of the questionnaire is valid and reliable. The method followed for its transcultural adaptation ensured its conceptual equivalence with the original questionnaire. Health practitioners can use the self-administered foot evaluation questionnaire as a complementary method to assess the interventions performed for ankle and foot disorders among native Spanish speakers; however, further research is necessary to assess its consistency for use by populations from other Spanish-speaking countries.
Collapse
Affiliation(s)
- Luci M Motta
- Hospital Perpetuo Socorro Calle León y Castillo 407, 35007 Las Palmas Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Ignacio Manchado
- Hospital Perpetuo Socorro Calle León y Castillo 407, 35007 Las Palmas Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Gustavo Blanco
- Hospital Perpetuo Socorro Calle León y Castillo 407, 35007 Las Palmas Spain
| | | | - Laura Garcés
- Terapias Acuáticas Canarias SL, Las Palmas Spain
| | - Gerardo L Garcés
- Hospital Perpetuo Socorro Calle León y Castillo 407, 35007 Las Palmas Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain.
| |
Collapse
|
2
|
Motta LM, Manchado I, Blanco G, Quintana-Montesdeoca MP, Garcés L, Garcés GL. Temporal Changes in Clinical Outcomes after Minimally Invasive Surgery for Hallux Valgus Correction in Women without Postoperative Complications. J Clin Med 2023; 12:4368. [PMID: 37445403 DOI: 10.3390/jcm12134368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 06/20/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023] Open
Abstract
Minimally invasive surgery (MIS) is currently used to correct hallux valgus deformities. Most studies reporting on MIS techniques to correct hallux valgus deformities included patients with postoperative complications. These reported complications, with an average rate of 23%, had significant negative effects on the clinical outcomes in this patient population. In the present study, a cohort of 63 women who underwent MIS hallux valgus correction was assessed preoperatively and at a mean follow-up of 1.0, 4.7, and 6.5 years using the American Orthopaedic Foot and Ankle Society (AOFAS) scale and the Manchester Oxford Foot Questionnaire (MOXFQ). The main criterion for inclusion in this cohort was a lack of complications during the entire follow-up period. The results showed significant improvements in both AOFAS and MOXFQ scores between the preoperative and 1-year follow-up assessments. By contrast, clinically small and nonsignificant changes were observed among postoperative follow-up values. The number of enrolled patients needs to be increased in future studies, with different surgeons and techniques included. Nevertheless, our study findings will inform patients about the outcomes they can expect over the years if no complications occur.
Collapse
Affiliation(s)
- Luci M Motta
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Department of Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35007 Las Palmas, Spain
| | - Ignacio Manchado
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Department of Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35007 Las Palmas, Spain
| | | | | | - Laura Garcés
- Terapias Acuáticas Canarias SL, 35007 Las Palmas, Spain
| | - Gerardo L Garcés
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Department of Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35007 Las Palmas, Spain
| |
Collapse
|
3
|
Manchado I, Motta LM, Blanco G, González J, Garcés GL. Isometric Knee Muscle Strength and Patient-Reported Measures Five Years after Anterior Cruciate Ligament Reconstruction: Comparison of Single versus Dual Autograft Hamstring Tendon Harvesting. J Clin Med 2022; 11:jcm11195682. [PMID: 36233550 PMCID: PMC9572358 DOI: 10.3390/jcm11195682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 09/17/2022] [Accepted: 09/20/2022] [Indexed: 11/23/2022] Open
Abstract
There is some controversy regarding the use of one or two hamstring tendons for anterior cruciate ligament reconstruction (ACLR). In this study, two cohorts of 22 male patients underwent an ACLR with hamstring tendon autografts. One cohort was reconstructed through an all-inside technique with the semitendinosus tendon (ST group) and the other with the semitendinosus and gracilis tendons (ST-G group). Anterior tibial translation (ATT), Lysholm, and IKDC scores were assessed preoperatively and five years postoperation. Additionally, isometric knee muscle strength was manually measured in both groups and in another cohort of 22 uninjured control male subjects five years after the operation. There were no significant differences in ATT and Lysholm scores between the operated groups. The IKDC score was lower in the ST-G group than in the ST group—9.57 (CI 14.89−4.25) (p < 0.001). No significant differences between injured and uninjured knees were detected in hamstring to quadriceps ratio strength and quadriceps limb symmetry index of the two operated groups, but the hamstring limb symmetry index was significantly lower in the ST-G group than in the ST and control groups. This study shows that using an ST-G autograft for ACLR yielded less flexor strength and worse results in some patient-reported outcome measures (PROM) than using an ST autograft five years after the operation. The observed results let us suggest that the use of one autograft hamstring tendon for ACLR is clinically preferable to the use of two hamstring tendons.
Collapse
Affiliation(s)
- Ignacio Manchado
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, Paseo Blas Cabrera Felipe s/n, 35016 Las Palmas, Spain
| | - Luci M. Motta
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, Paseo Blas Cabrera Felipe s/n, 35016 Las Palmas, Spain
| | | | - Jesús González
- Unidad de Investigación, Hospital Dr Negrin, 35007 Las Palmas, Spain
| | - Gerardo L. Garcés
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, Paseo Blas Cabrera Felipe s/n, 35016 Las Palmas, Spain
- Correspondence: ; Tel.: +34-696-471-915
| |
Collapse
|
4
|
Motta LM, Manchado I, Blanco G, García-Flemate F, González J, Garcés GL. Pre- and Post-Operative Relationship between Radiological Measures and Clinical Outcomes in Women with Hallux Valgus. J Clin Med 2022; 11:jcm11133626. [PMID: 35806910 PMCID: PMC9267403 DOI: 10.3390/jcm11133626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 06/14/2022] [Accepted: 06/21/2022] [Indexed: 11/22/2022] Open
Abstract
The surgical correction of a hallux valgus (HV) deformity improves radiological parameters and clinical outcomes. However, it is not known how these improvements are related between themselves. In this retrospective study, 73 women were assessed preoperatively and 60 months after HV surgical correction. Several radiological parameters were measured: the hallux valgus angle (HVA), I−II intermetatarsal angle (IMA) and sesamoid position. The functional outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Hallux Metatarsophalangeal-Interphalangeal (HMI) scale, and patient-reported outcomes (PROMs) were recorded with the Manchester−Oxford Foot Questionnaire (MOXFQ). A pre−post-surgery comparison of radiological and clinical values was performed, the correlation among them was studied and the differences pre−post-surgery in the radiological measurements compared with those for the clinical outcomes were studied. The results show that all the radiological parameters, functional outcomes and PROMs improved significantly from their pre-operative values to the follow-up values. Multivariate regression analysis showed a significant relationship (p < 0.001) between the differential pre−post-surgery AOFAS scoring only with two sesamoid position differential pre−post-surgery measures: position of medial sesamoid (PMS) and translation of the first metatarsal head (TMH). However, no significant association was observed between the pre−post-surgery radiological differences and the pre−post-surgery MOXFQ scoring.
Collapse
Affiliation(s)
- Luci M. Motta
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain; (L.M.M.); (I.M.); (G.B.); (F.G.-F.)
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35016 Las Palmas, Spain
| | - Ignacio Manchado
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain; (L.M.M.); (I.M.); (G.B.); (F.G.-F.)
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35016 Las Palmas, Spain
| | - Gustavo Blanco
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain; (L.M.M.); (I.M.); (G.B.); (F.G.-F.)
| | - Felipe García-Flemate
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain; (L.M.M.); (I.M.); (G.B.); (F.G.-F.)
| | - Jesús González
- Unidad de Investigación, Hospital Dr Negrin, 35007 Las Palmas, Spain;
| | - Gerardo L. Garcés
- Hospital Perpetuo Socorro, 35007 Las Palmas, Spain; (L.M.M.); (I.M.); (G.B.); (F.G.-F.)
- Departamento de Ciencias Médicas y Quirúrgicas, University of Las Palmas de Gran Canaria, 35016 Las Palmas, Spain
- Correspondence: ; Tel.: +34-696-471-915
| |
Collapse
|
5
|
Garcés GL, Martel O, Yánez A, Manchado-Herrera I, Motta LM. In Vitro Testing of 2 Adjustable-Loop Cortical Suspensory Fixation Systems Versus Interference Screw for Anterior Cruciate Ligament Reconstruction. Orthop J Sports Med 2021; 9:23259671211031652. [PMID: 35146030 PMCID: PMC8821986 DOI: 10.1177/23259671211031652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 03/24/2021] [Indexed: 11/23/2022] Open
Abstract
Background: It is not clear whether the mechanical strength of adjustable-loop suspension devices (ALDs) in anterior cruciate ligament (ACL) reconstruction is device dependent and if these constructs are different from those of an interference screw. Purpose: To compare the biomechanical differences of 2 types of ALDs versus an interference screw. Study Design: Controlled laboratory study. Methods: ACL reconstruction was performed on porcine femurs and bovine extensor tendons with 3 types of fixation devices: interference screw, UltraButton (UB) ALD, and TightRope (TR) ALD (n = 10 for each). In addition to specimen testing, isolated testing of the 2 ALDs was performed. The loading protocol consisted of 3 stages: preload (static 150 N load for 5 minutes), cyclic load (50-250 N at 1 Hz for 1000 cycles), and load to failure (crosshead speed 50 mm/min). Displacement at different cycles, ultimate failure load, yield load, stiffness, and failure mode were recorded. Results: In specimen testing, displacement of the ALDs at the 1000th cycle was similar (3.42 ± 1.34 mm for TR and 3.39 ± 0.92 mm for UB), but both were significantly lower than that of the interference screw (7.54 ± 3.18 mm) (P < .001 for both). The yield load of the UB (547 ± 173 N) was higher than that of the TR (420 ± 72 N) (P = .033) or the interference screw (386 ± 51 N; P = .013), with no significant difference between the latter 2. In isolated device testing, the ultimate failure load of the TR (862 ± 64 N) was significantly lower than that of the UB (1879 ± 126 N) (P < .001). Conclusion: Both ALDs showed significantly less displacement in cyclic loading at ultimate failure than the interference screw. The yield load of the UB was significantly higher than that of the other 2. The ultimate failure occurred at a significantly higher load for UB than it did for TR in isolated device testing. Clinical Relevance: Both UB and TR provided stronger fixation than an interference screw. Although difficult to assess, intrinsic differences in the mechanical properties of these ALDs may affect clinical outcomes.
Collapse
Affiliation(s)
- Gerardo L. Garcés
- Department of Medical and Surgical Sciences, University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Oscar Martel
- Department of Mechanical Engineering, University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Alejandro Yánez
- Department of Mechanical Engineering, University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | | | - Luci M. Motta
- University of Las Palmas de Gran Canaria, Las Palmas, Spain
| |
Collapse
|
6
|
Manchado-Herrera I, Motta LM, Blanco G, González J, Garcés GL. Anterior tibial translation and patient-reported outcomes after anterior cruciate ligament reconstruction with a tape locking screw: A 5-year follow-up study. Orthop Traumatol Surg Res 2021; 107:102790. [PMID: 33333269 DOI: 10.1016/j.otsr.2020.102790] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/22/2020] [Accepted: 06/01/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND The Tape Locking Screw system (TLS) is a recognised technique used in anterior cruciate ligament reconstruction (ACLR). However, only a few previous studies have reported associated outcomes, all of which had been examined over a short-term period. The aim of this study was to assess the time-dependent changes in the objective and patient-reported outcome measures (PROM) in a group of patients with anterior cruciate ligament deficiency who have been operated on with this technique. HYPOTHESIS Previously reported satisfactory short-term outcomes following TLS persist for several years after the operation. PATIENTS AND METHODS This study was a retrospective observational study including 26 patients, who were followed after unilateral ACLR with TLS. Anterior tibial translation (ATT) was measured in both knees using the KT-1000 arthrometer and two PROMs: International Knee Documentation Committee (IKDC) and Lysholm subjective form scores were examined preoperatively, 6 months postoperatively, and annually for 5 years thereafter in all patients. RESULTS One patient suffered a rupture of the graft, and one patient had a screw loosening. Two patients were lost for follow-up, so 22 patients were the final study group. Median (25-75%) ATT side-to-side differences between the injured and uninjured sides were 4 (3,5-4)mm preoperatively, 0,75 (0-1)mm 1 year postoperatively, and 0,75 (0-1)mm 5 years after the operation (P<0.001). Median (25-75%) IKDC scores were 44.25 (35.6-55.15), 92.55 (87.08-96.6), and 95.4 (90.8-97.7) points preoperatively and 1 year (P<0.001) and 5 years postoperatively, respectively. Median (25-75%) Lysholm scores were 52 (38.75-64.5), 95.5 (94.75-99.25), and 97.5 (95-99) points preoperatively and 1 year (P<0.001) and 5 years postoperatively, respectively. DISCUSSION ACLR with TLS might already achieve favourable outcomes 1 year postoperatively, when measured objectively (ATT) and with PROMs. These outcomes persist 5 year postoperatively. LEVEL OF EVIDENCE IV: retrospective cohort study.
Collapse
Affiliation(s)
- Ignacio Manchado-Herrera
- Hospital Perpetuo Socorro, Las Palmas, Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | - Luci M Motta
- Hospital Perpetuo Socorro, Las Palmas, Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain
| | | | - Jesús González
- Statistical Research Unit, Hospital Dr Negrin, Las Palmas, Spain
| | - Gerardo L Garcés
- Hospital Perpetuo Socorro, Las Palmas, Spain; University of Las Palmas de Gran Canaria, Las Palmas, Spain.
| |
Collapse
|
7
|
Gomes FM, Ramos IB, Motta LM, Miranda K, Santiago MF, de Souza W, Machado EA. Polyphosphate polymers during early embryogenesis of Periplaneta americana. J Insect Physiol 2008; 54:1459-1466. [PMID: 18773905 DOI: 10.1016/j.jinsphys.2008.07.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2008] [Revised: 07/25/2008] [Accepted: 07/30/2008] [Indexed: 05/26/2023]
Abstract
Inorganic polyphosphates (PolyP) are linear polymers of phosphate (Pi) residues linked by high-energy phosphoanhydride bonds. Despite a wide distribution, their role during insect embryogenesis has not been examined so far. In this study, we show the mobilization of PolyP polymers during the embryogenesis of the cockroach Periplaneta americana. PolyP was detected by enzymatic and fluorimetric assays and found to accumulate in two main sizes by agarose gel electrophoresis. Confocal microscopy showed their presence in small vesicles. In addition, X-ray microanalysis of small vesicles showed considerable amounts of calcium, sodium and magnesium, suggesting an association of PolyP with these elements. Variations of the free Ca+2, Pi and PolyP levels were observed during the first days of embryogenesis. Our results are consistent with the hypothesis that phosphate ions modulate PolyP variation and that PolyP hydrolysis result in increasing free Ca+2 levels. This is the first investigation of PolyP metabolism during embryogenesis of an insect and might shed light on the mechanisms involving Pi storage and homeostasis during this period. We suggest that PolyP, mainly stored in small vesicles, might be involved in the functional control of Ca+2 and Pi homeostasis during early embryogenesis of P. Americana.
Collapse
Affiliation(s)
- F M Gomes
- Laboratório de Entomologia Médica, Programa de Parasitologia e Biologia Celular, Instituto de Biofísica Carlos Chagas Filho, Universidade Federal do Rio de Janeiro, Cidade Universitária. Rio de Janeiro, 21941-590, RJ, Brazil
| | | | | | | | | | | | | |
Collapse
|