1
|
Burgués J, Doñate S, Esclapez MD, Saúco L, Marco S. Characterization of odour emissions in a wastewater treatment plant using a drone-based chemical sensor system. Sci Total Environ 2022; 846:157290. [PMID: 35839880 DOI: 10.1016/j.scitotenv.2022.157290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 07/04/2022] [Accepted: 07/07/2022] [Indexed: 06/15/2023]
Abstract
Conventionally, odours emitted by different sources present in wastewater treatment plants (WWTPs) are measured by dynamic olfactometry, where a human panel sniffs and analyzes air bags collected from the plant. Although the method is considered the gold standard, the process is costly, slow, and infrequent, which does not allow operators to quickly identify and respond to problems. To better monitor and map WWTP odour emissions, here we propose a small rotary-wing drone equipped with a lightweight (1.3-kg) electronic nose. The "sniffing drone" sucks in air via a ten-meter (33-foot) tube and delivers it to a sensor chamber where it is analyzed in real-time by an array of 21 gas sensors. From the sensor signals, machine learning (ML) algorithms predict the odour concentration that a human panel using the EN13725 methodology would report. To calibrate and validate the predictive models, the drone also carries a remotely controlled sampling device (compliant with EN13725:2022) to collect sample air in bags for post-flight dynamic olfactometry. The feasibility of the proposed system is assessed in a WWTP in Spain through several measurement campaigns covering diverse operating regimes of the plant and meteorological conditions. We demonstrate that training the ML algorithms with dynamic (transient) sensor signals measured in flight conditions leads to better performance than the traditional approach of using steady-state signals measured in the lab via controlled exposures to odour bags. The comparison of the electronic nose predictions with dynamic olfactometry measurements indicates a negligible bias between the two measurement techniques and 95 % limits of agreement within a factor of four. This apparently large disagreement, partly caused by the high uncertainty of olfactometric measurements (typically a factor of two), is more than offset by the immediacy of the predictions and the practical advantages of using a drone-based system.
Collapse
Affiliation(s)
- Javier Burgués
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain; Department of Electronics and Biomedical Engineering, Universitat de Barcelona, Marti i Franqués 1, 08028 Barcelona, Spain
| | - Silvia Doñate
- Depuración de Aguas del Mediterráneo (DAM), Avenida Benjamín Franklin 21, Parque Tecnológico, Paterna 46980, Spain
| | - María Deseada Esclapez
- Depuración de Aguas del Mediterráneo (DAM), Avenida Benjamín Franklin 21, Parque Tecnológico, Paterna 46980, Spain
| | - Lidia Saúco
- Depuración de Aguas del Mediterráneo (DAM), Avenida Benjamín Franklin 21, Parque Tecnológico, Paterna 46980, Spain
| | - Santiago Marco
- Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Baldiri Reixac 10-12, 08028 Barcelona, Spain; Department of Electronics and Biomedical Engineering, Universitat de Barcelona, Marti i Franqués 1, 08028 Barcelona, Spain.
| |
Collapse
|
2
|
Tudela I, Sáez V, Esclapez MD, Díez-García MI, Bonete P, González-García J. Simulation of the spatial distribution of the acoustic pressure in sonochemical reactors with numerical methods: a review. Ultrason Sonochem 2014; 21:909-919. [PMID: 24355287 DOI: 10.1016/j.ultsonch.2013.11.012] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Revised: 11/12/2013] [Accepted: 11/17/2013] [Indexed: 06/03/2023]
Abstract
Numerical methods for the calculation of the acoustic field inside sonoreactors have rapidly emerged in the last 15 years. This paper summarizes some of the most important works on this topic presented in the past, along with the diverse numerical works that have been published since then, reviewing the state of the art from a qualitative point of view. In this sense, we illustrate and discuss some of the models recently developed by the scientific community to deal with some of the complex events that take place in a sonochemical reactor such as the vibration of the reactor walls and the nonlinear phenomena inherent to the presence of ultrasonic cavitation. In addition, we point out some of the upcoming challenges that must be addressed in order to develop a reliable tool for the proper designing of efficient sonoreactors and the scale-up of sonochemical processes.
Collapse
Affiliation(s)
- Ignacio Tudela
- The Functional Materials Applied Research Group, Faculty of Health and Life Sciences, Coventry University, Priory Street, Coventry CV1 5FB, United Kingdom.
| | - Verónica Sáez
- Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica: Sonoelectroquímica y Bioelectroquímica, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | - María Deseada Esclapez
- Grupo de Fotoquímica y Electroquímica de Semiconductores, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | - María Isabel Díez-García
- Grupo de Fotoquímica y Electroquímica de Semiconductores, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | - Pedro Bonete
- Grupo de Fotoquímica y Electroquímica de Semiconductores, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | - José González-García
- Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica: Sonoelectroquímica y Bioelectroquímica, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| |
Collapse
|
3
|
Esclapez MD, Díez-García MI, Sàez V, Bonete P, González-García J. Electrochemical degradation of trichloroacetic acid in aqueous media: influence of the electrode material. Environ Technol 2013; 34:383-393. [PMID: 23530352 DOI: 10.1080/09593330.2012.696723] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The electrochemical degradation of trichloroacetic acid (TCAA) in water has been analysed through voltammetric studies with a rotating disc electrode and controlled-potential bulk electrolyses. The influence of the mass-transport conditions and initial concentration of TCAA for titanium, stainless steel and carbon electrodes has been studied. It is shown that the electrochemical reduction of TCAA takes place prior to the massive hydrogen evolution in the potential window for all electrode materials studied. The current efficiency is high (> 18%) compared with those normally reported in the literature, and the fractional conversion is above 50% for all the electrodes studied. Only dichloroacetic acid (DCAA) and chloride anions were routinely detected as reduction products for any of the electrodes, and reasonable values of mass balance error were obtained. Of the three materials studied, the titanium cathode gave the best results.
Collapse
Affiliation(s)
- M D Esclapez
- Grupo de Fotoquímica y Electroquímica de Semiconductores, Departamento de Química Física, Instituto Universitario de Electroquímica, Universidad de Alicante, Alicante, Spain
| | | | | | | | | |
Collapse
|
4
|
Esclapez MD, Díez-García MI, Sáez V, Tudela I, Pérez JM, González-García J, Bonete P. Spectroelectrochemical study of trichloroacetic acid reduction at copper electrodes in an aqueous sodium sulfate medium. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.05.133] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Sáez V, Esclapez MD, Frías-Ferrer AJ, Bonete P, Tudela I, Díez-García MI, González-García J. Lead dioxide film sonoelectrodeposition in acidic media: Preparation and performance of stable practical anodes. Ultrason Sonochem 2011; 18:873-880. [PMID: 21195010 DOI: 10.1016/j.ultsonch.2010.11.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2010] [Accepted: 11/26/2010] [Indexed: 05/30/2023]
Abstract
Practical lead dioxide anodes have been obtained by electrodeposition on glassy carbon and titanium substrates in the presence and in the absence of an ultrasound field. The films obtained by mechanical agitation on glassy carbon are strongly improved when the electrodeposition process is carried out with the ultrasound field, providing adherent deposits free from nodules and stress, but with pores appearing occasionally. These enhanced properties were not achieved by mechanical conditions, even when optimization of temperature, current density, additives and geometrical aspects was attempted. The best practical anodes were obtained by sonoelectrodeposition using specially treated titanium as substrate, providing comparable behavior to commercial electrodes.
Collapse
Affiliation(s)
- V Sáez
- Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica: Sonoelectroquimica y Bioelectroquimica, Dpto. de Química Física e Instituto de Electroquimíca, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | | | | | | | | | | | | |
Collapse
|
6
|
Sáez V, Esclapez MD, Bonete P, Walton DJ, Rehorek A, Louisnard O, González-García J. Sonochemical degradation of perchloroethylene: the influence of ultrasonic variables, and the identification of products. Ultrason Sonochem 2011; 18:104-113. [PMID: 20403718 DOI: 10.1016/j.ultsonch.2010.03.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Revised: 03/05/2010] [Accepted: 03/22/2010] [Indexed: 05/29/2023]
Abstract
Sonochemistry is a technique that offers promise for pollutant degradation, but earlier studies on various chlorinated substrates do not give a definitive view of the effectiveness of this methodology. We now report a thorough study of ultrasonic operational variables upon perchloroethylene (PCE) degradation in water (variables include ultrasonic frequency, power and system geometry as well as substrate concentration) and we attempt to close the mass balance where feasible. We obtained fractional conversions of >97% showing very effective loss of pollutant starting material, and give mechanistic proposals for the reaction pathway based on cavitational phenomena inducing pyrolytic and free radical processes. We note major products of Cl(-) and CO(2)/CO, and also trichloroethylene (TCE) and dichloroethylene (DCE) at ppm concentrations as reported earlier. The formation at very low (ppb) concentration of small halocompounds (CHCl(3), CCl(4)) and also of higher-mass species, such as pentachloropropene, hexachloroethane, is noteworthy. But of particular importance in our work is the discovery of significant quantities of chloroacetate derivatives at ppm concentrations. Although these compounds have been described as by-products with other techniques such as radiolysis or photochemistry, this is the first time that these products have been identified in the sonochemical treatment of PCE; this allows a much more effective account of the mass balance and may explain earlier inconsistencies. This reaction system is now better identified, but a corollary is that, because these haloacetates are themselves species of some toxicity, the use of ultrasound here may not sufficiently diminish wastewater toxicity.
Collapse
Affiliation(s)
- V Sáez
- Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica: Sonoelectroquímica y Bioelectroquímica, Departamento de Química Física e Instituto Universitario de Electroquímica, Universidad de Alicante, Ap. Correos 99, 03080 Alicante, Spain
| | | | | | | | | | | | | |
Collapse
|
7
|
Sáez V, Esclapez MD, Tudela I, Bonete P, Louisnard O, González-García J. 20 kHz sonoelectrochemical degradation of perchloroethylene in sodium sulfate aqueous media: influence of the operational variables in batch mode. J Hazard Mater 2010; 183:648-654. [PMID: 20705391 DOI: 10.1016/j.jhazmat.2010.07.074] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Revised: 07/15/2010] [Accepted: 07/16/2010] [Indexed: 05/29/2023]
Abstract
A preliminary study of the 20 kHz sonoelectrochemical degradation of perchloroethylene in aqueous sodium sulfate has been carried out using controlled current density degradation sonoelectrolyses in batch mode. An important improvement in the viability of the sonochemical process is achieved when the electrochemistry is implemented, but the improvement of the electrochemical treatment is lower when the 20 kHz ultrasound field is simultaneously used. A fractional conversion of 100% and degradation efficiency around 55% are obtained independently of the ultrasound power used. The current efficiency is also enhanced compared to the electrochemical treatment and a higher speciation is also detected; the main volatile compounds produced in the electrochemical and sonochemical treatment, trichloroethylene and dichloroethylene, are not only totally degraded, but also at shorter times than in the sonochemical or electrochemical treatments.
Collapse
Affiliation(s)
- Verónica Sáez
- Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica: Sonoelectroquímica y Bioelectroquímica, Ap. Correos 99, 03080 Alicante, Spain
| | | | | | | | | | | |
Collapse
|
8
|
Esclapez MD, Sáez V, Milán-Yáñez D, Tudela I, Louisnard O, González-García J. Sonoelectrochemical treatment of water polluted with trichloroacetic acid: from sonovoltammetry to pre-pilot plant scale. Ultrason Sonochem 2010; 17:1010-1020. [PMID: 20022544 DOI: 10.1016/j.ultsonch.2009.11.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Revised: 11/11/2009] [Accepted: 11/13/2009] [Indexed: 05/28/2023]
Abstract
The sonoelectrochemical treatment of aqueous solutions of trichloroacetic acid (TCAA) has been scaled-up from the voltammetric analysis to pre-pilot stage. The degradation in absence of ultrasound field has yield to a poor performance which has been improved in presence of ultrasound. The sonovoltametry study has provided the range of potentials and/or current densities to be used with the lowest current efficiency penalty. Sonoelectrolyses at batch scale (carried out with a horn-transducer 24 kHz positioned at about 3 cm from the surface of the electrode) achieved little improvement in the degradation. However, when a specifically designed sonoelectrochemical reactor (not optimized) was used during the scale-up, the presence of ultrasound field provided better results (fractional conversion 97%, degradation efficiency 26%, selectivity 0.92 and current efficiency 8%) at lower ultrasonic intensities and volumetric flow.
Collapse
Affiliation(s)
- M D Esclapez
- Departamento de Química Física, Universidad de Alicante, Alicante, Spain
| | | | | | | | | | | |
Collapse
|
9
|
González-García J, Esclapez MD, Bonete P, Hernández YV, Garretón LG, Sáez V. Current topics on sonoelectrochemistry. Ultrasonics 2010; 50:318-322. [PMID: 19853270 DOI: 10.1016/j.ultras.2009.09.022] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2009] [Revised: 09/20/2009] [Accepted: 09/20/2009] [Indexed: 05/28/2023]
Abstract
Sonoelectrochemistry is undergoing a reemerging activity in the last years with an increasing number of papers appearing in a wide range of peer review journals. Applied studies which cover environmental treatments, synthesis or characterization of nanostructures, polymeric materials synthesis, analytical procedures, films preparations, membrane preparations among other interesting applications have been reviewed. The revised fundamental analyses trying to elucidate the mechanism of the interactions between the ultrasound and electrical fields, are focused on test electrochemical processes, on the use of unconventional solvents and combination with other techniques. After the review of the achievements and faults of sonoelectrochemistry, future research lines are suggested.
Collapse
Affiliation(s)
- José González-García
- University of Alicante, Departamento de Química Física e Instituto Universitario de Electroquímica, Grupo de Nuevos Desarrollos Tecnológicos en Electroquímica, Sonoelectroquímica y Bioelectroquímica, Ap. Correos 99, 03080 Alicante, Spain.
| | | | | | | | | | | |
Collapse
|