1
|
Gelio MB, Zaniboni JF, Monteiro J, Besegato JF, Pereira JR, Buchaim RL, Kuga MC. Medium-term evaluation of the bond strength and dentin penetration of self-adhesive resin cements to root dentin. Aust Dent J 2023. [PMID: 37888911 DOI: 10.1111/adj.12988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2023] [Indexed: 10/28/2023]
Abstract
BACKGROUND Medium-term evaluate the bond strength and tag formation in root dentin using self-adhesive cements Maxcem Elite (MCE), Relyx U200 (RU2), SeT PP (SPP) and Megalink (MGL) compared to conventional cement Relyx ARC (ARC) for glass fibre post cementation. MATERIALS AND METHODS One hundred bovine incisors roots were endodontically treated and divided into 5 groups (n = 20) according to the cementation system: MCE, RU2, SPP, MGL and ARC. All cementation systems were evaluated at 24 h (1) and 12 months (2) after post cementation. Specimens from the cervical, middle and apical thirds of the root were submitted to push-out bond strength test and confocal laser microscopy to verify the dentin penetration. The adhesive failure mode was classified as adhesive, cohesive and mixed. Data were analysed by one-way ANOVA and Tukey tests (α = 5%). RESULTS ARC-1 and ARC-12 showed the highest bond strength (P < 0.05). ARC showed the greatest tag extension, regardless of the third (P < 0.05). The most frequent failure mode in the 24-h analysis was cohesive, regardless of the cement used. For the 12-month analysis, mixed failure was the most frequent. CONCLUSION Conventional cement (ARC) showed the highest bond strength and tag extension, regardless of the evaluation period. In all cementation systems, the bond strength decreased after 12 months. © 2023 Australian Dental Association.
Collapse
Affiliation(s)
- M B Gelio
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil
| | - J F Zaniboni
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil
| | - Jcc Monteiro
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil
| | - J F Besegato
- School of Dentistry (FAODO), Federal University of Mato Grosso do Sul (UFMS), Campo Grande, Mato Grosso, Brazil
| | - J R Pereira
- University of Southern Santa Catarina, Tubarão, Santa Catarina, Brazil
| | - R L Buchaim
- Department of Biological Sciences - Anatomy, Bauru School of Dentistry, Universidade de São Paulo - USP, São Paulo, Bauru, Brazil
| | - M C Kuga
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP), Araraquara, Brazil
| |
Collapse
|
2
|
Costa JLDSG, Gelio MB, Galvani LD, Besegato JF, Bordini EAF, Godoy EF, Vaz LG, Kuga MC. Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser. Dent Mater J 2023; 42:654-658. [PMID: 37460305 DOI: 10.4012/dmj.2023-017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10- 15- and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure.
Collapse
Affiliation(s)
| | - Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University -UNESP
| | - Lucas David Galvani
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University -UNESP
| | | | - Ester Alves Ferreira Bordini
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo -USP
| | | | - Luis Geraldo Vaz
- Department of Dental Materials and Prosthodontics, School of Dentistry, São Paulo State University -UNESP
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais -UFMG
| |
Collapse
|
3
|
Nogueira CHDP, Gelio MB, Besegato JF, Ramos ATPR, Fernández E, Kuga MC, Saad JRC. Effect of aging and cementation systems on the bond strength to root dentin after fiber post cementation. Braz Dent J 2023; 34:52-60. [PMID: 36888845 PMCID: PMC10027095 DOI: 10.1590/0103-6440202305082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 12/07/2022] [Indexed: 03/08/2023] Open
Abstract
This study evaluated the effect of aging and cementation of fiber posts using glass ionomer and resin cements on push-out bond strength, failure mode, and resin tag formation. One hundred and twenty bovine incisors were used. After post-space preparation, the specimens were randomly allocated into 12 groups (n = 10) according to the cementation system used: GC - GC Gold Label Luting & Lining); RL - RelyX Luting 2; MC - MaxCem Elite; RU - RelyX U200 and the aging periods (24 hours, 6 months, and 12 months). Slices from the cervical, middle, and apical thirds were obtained and analyzed by push-out bond strength test and confocal laser scanning microscopy. One-way ANOVA and Tukey's post-hoc test was used at a significance level of 5%. For the push-out bond strength test, no differences among GC, RU, and MC in the cervical and middle thirds were observed, regardless of the period of storage (P > 0.05). In the apical third, GC and RU showed similar bond strength but higher than other groups (P > 0.05). After 12 months, GC showed the highest bond strength (P < 0.05). Bond strength to post-space dentin decreased over time, regardless of the cementation system used. Cohesive failure was the most frequent, regardless of the period of storage, cementation system, and post-space third. Tag formation was similar among all groups. After 12 months, GC showed the highest bond strength values.
Collapse
Affiliation(s)
- Caio Henrique de Paula Nogueira
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Anna Thereza Peroba Rezende Ramos
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - Eduardo Fernández
- Department of Restorative Dentistry, University of Chile, Santiago,
Chile
- Institute of Biomedical Sciences, Autonomous University of Chile,
Providencia, Chile
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| | - José Roberto Cury Saad
- Department of Restorative Dentistry, School of Dentistry,
Araraquara, São Paulo State University - UNESP, Araraquara, São Paulo, Brazil
| |
Collapse
|
4
|
Manzoli TM, Costa JLDSG, Besegato JF, Gelio MB, Galvani LD, Bordini EAF, Kuga MC, Dantas AAR. Violet LED associated with high concentration hydrogen peroxide: Effects on bleaching efficacy, pH, and temperature. Photodiagnosis Photodyn Ther 2022; 40:103133. [PMID: 36162757 DOI: 10.1016/j.pdpdt.2022.103133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Revised: 09/13/2022] [Accepted: 09/21/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND This study aimed to evaluate the bleaching efficacy, pH, and temperature of 35% hydrogen peroxide (HP) gel used alone or associated with violet LED. METHODS Sixty bovine crowns were sectioned (5 × 5 × 2mm). After staining with black tea, the specimens were randomized into four groups (n = 10) according to the bleaching protocol: HP35R: 3 × 15 min 35% HP; HP35: 1 × 45 min 35% HP; HP35VR: 3 × 8min 35% HP + Violet LED; HP35V: 1 × 24 min + Violet LED. Two bleaching sessions were performed for all the groups. Color change was evaluated before, 24h after each session, 7 days and 15 days after the last session. The variables ∆E00 [CIEDE2000] and WID were used for color analysis. The pH variation (initial and final) and the temperature of the gel were recorded (n = 5). ANOVA two-way for repeated measures and Bonferroni post-test was used at a significance level of 5%. RESULTS HP35VR and HP35V the most noticeable color change(p < 0.05). The final values of pH were lower than the initial ones, but with no difference between the groups (p > 0.05). Groups HP35VR and HP35V showed an increase in temperature in relation to HP35R (p < 0.05). CONCLUSIONS Violet LED improved the bleaching efficacy of 35% HP in a time-saving manner without negatively affecting the pH and temperature of 35% HP. The renewal of HP did not influence the outcomes.
Collapse
Affiliation(s)
- Tatiane Miranda Manzoli
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Joatan Lucas de Sousa Gomes Costa
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Lucas David Galvani
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Ester Alves Ferreira Bordini
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo - USP, Alameda Dr. Octávio Pinheiro Brisolla, 9-75, ZIP Code 17012-901, Bauru, São Paulo, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| | - Andréa Abi Rached Dantas
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, 1680 Humaitá Street - 3rd floor, Centro, Mail Box: 331, ZIP Code 14801-903, Araraquara, São Paulo, Brazil.
| |
Collapse
|
5
|
Belizario LG, Piragine TL, Girotto AC, Gelio MB, Pereira JR, Fernandez E, Kuga MC. Effect of Different Irrigants on the Adhesive Interface and Influence on the Push Out Strength of Fiber Posts. Oper Dent 2022; 47:E211-E221. [PMID: 36121721 DOI: 10.2341/21-038-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/30/2022] [Indexed: 11/23/2022]
Abstract
PURPOSE The aim of this study was to evaluate the effects of a new irrigant solution on the post space cleaning and the adhesive resistance of fiber posts. METHODS AND MATERIALS Eighty roots of bovine teeth were randomly allocated into eight groups (n=10 for each group). Evaluations were performed in two different time points for each irrigant. The irrigants included a control group with distilled water (DW), 2.5% NaOCl and 17% EDTA (SH), 1% peracetic acid (PA), and 5% boric acid and 1% citric acid (EX). The time points were 24 hours (I-immediate) and 6 months (D-delayed). The push-out test was performed using a universal testing machine with a 5 kN load cell operating at a crosshead speed of 0.5 mm/minute. The dentinal cementation system was analyzed using a laser confocal microscope (LSM5; Zeiss, Jena, Germany), and incidence of residue on radicular dentin was evaluated by scanning electron microscopy (SEM). The incidence of residue was evaluated by the Kruskal-Wallis test and push-out bond strength and dentin penetrability were evaluated via a oneway analysis of variance (ANOVA) and Tukey tests (α=0.05). RESULTS The EX irrigation protocol demonstrated the lowest incidence of residue on the dentin surface (p<0.05), independently of the evaluated third. In the cervical and the middle post thirds, EXI, EXD, SHI, and SHD groups exhibited similar push-out bond strength values (p>0.05). EXI, EXD, PAI, and PAD exhibited the greatest dentinal penetrability of the cementation system in all the post thirds (p<0.05). CONCLUSIONS A solution containing 5% boric acid and 1% citric acid can be a promising irrigant for radicular post space cleaning. It has adequate potential for cleaning the dentin surface without interfering with the adhesive interface between the dentin and the cementation system.
Collapse
Affiliation(s)
- L G Belizario
- Laurie Garcia Belizario, DDS, MSc, PhD, Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, SP, Brazil; and St Humaitá, 1680 - Center, 14801-903, Araraquara - SP, Brazil
| | - T L Piragine
- Thais Leandrin Piragine, DDS, MSc, PhD, Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, SP, Brazil; and St Humaitá, 1680 - Center, 14801-903, Araraquara - SP, Brazil
| | - A C Girotto
- AC Girotto, DDS, MSc, PhD, Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, SP, Brazil; and St Humaitá, 1680 - Center, 14801-903, Araraquara - SP, Brazil
| | - M B Gelio
- Mariana Bela Gelio, DDS, MSc, Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, SP, Brazil; and St Humaitá, 1680 - Center, 14801-903, Araraquara - SP, Brazil
| | - J R Pereira
- Jefferson Ricardo Pereira, DDS, MSc, PhD, Department of Restorative Dentistry, School of Dentistry Chile, Chile
| | - E Fernandez
- *Eduardo Fernandez, DDS, PhD, Universidad de Chile , Facultad de Odontologia, Departamento de Odontologia Restauradora and Instituto de Ciencias Biomédicas, Universidad Autónoma de Chile
| | - M C Kuga
- Milton Kuga, DDS, MSc, PhD, Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, SP, Brazil; and St Humaitá, 1680 - Center, 14801-903, Araraquara - SP, Brazil
| |
Collapse
|
6
|
Gomes Costa JLDS, Besegato JF, Zaniboni JF, Vitória MS, Gelio MB, Kuga MC. Whitening efficacy of low concentration hydrogen peroxide photoactivated with blue or violet LED. Photodiagnosis Photodyn Ther 2022; 39:103028. [PMID: 35872355 DOI: 10.1016/j.pdpdt.2022.103028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/13/2022] [Accepted: 07/20/2022] [Indexed: 10/17/2022]
Abstract
BACKGROUND Bleaching protocols using low concentration hydrogen peroxide (HP) photoactivated with LED sources have been widely discussed. We evaluated the whitening efficacy of 15% HP photoactivated with blue or violet LED compared to 35% HP. METHODS Thirty bovine crowns were sectioned into 5 × 5 × 2mm specimens. After staining in black tea, the specimens were randomized into three groups (n=10): 35% HP, 15% HP + blue LED and 15% HP + violet LED. Two bleaching sessions were performed and the color assessment (∆L*, ∆a*, ∆b*, ∆Eab [CIELab], ∆E00 [CIEDE2000] and WID) was performed before, 24h after each session, 7 days and 1 month after the last session. Data were evaluated by two-way repeated measures ANOVA and Bonferroni post-test at a significance level of 5%. RESULTS All groups showed effective and similar results over 1 month of follow-up (p > 0.05), with only intragroup differences among the time intervals (p < 0.05). CONCLUSIONS The use of 15% HP photoactivated with blue or violet LED showed similar whitening efficacy compared to 35% HP. Thus, the association of low concentration bleaching gels with LED sources can provide a successful and less aggressive treatment in terms of color change.
Collapse
Affiliation(s)
| | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, SP, Brazil.
| | - Joissi Ferrari Zaniboni
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, SP, Brazil.
| | - Matheus Sousa Vitória
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, SP, Brazil.
| | - Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, SP, Brazil.
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, Araraquara, São Paulo State University - UNESP, Araraquara, SP, Brazil.
| |
Collapse
|
7
|
Gelio MB, Ramos ATPR, Zaniboni JF, Escalante-Otárola WG, Besegato JF, Kuga MC. Effect of irrigation protocols on chemical smear layer formation over the post-space dentin. Microsc Res Tech 2022; 85:3005-3013. [PMID: 35535716 DOI: 10.1002/jemt.24149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 04/10/2022] [Accepted: 05/01/2022] [Indexed: 11/12/2022]
Abstract
This study evaluated the effect of irrigation protocols using 95% ethanol (ET) or 1% peracetic acid (PA) prior the use of 2% chlorhexidine (CHX) compared to distilled water (DW) on the chemical smear layer (CSL) formation and incidence of open dentin tubules at the apical, medium, and cervical third of the post-space dentin. Scanning electron microscopy (SEM) and electron dispersive spectroscopy (EDS) images were used. Forty bovine roots were endodontically treated. After, post-space preparation was performed and the roots were randomized in four groups (n = 10) according to the irrigation protocol: DW, CHX, CHX-ET and CHX-PA. The chemical composition of CSL and the incidence of open dentin tubules at the post-space thirds were evaluated by EDS (500× magnification) and SEM (2000× magnification) images, respectively. Data from chemical composition of CSL were descriptively analyzed, while the incidence of open dentin tubules was evaluated by scores and submitted to Kruskal-Wallis and Dunn test (p = .05). Cl, Bi, and Si were the chemical elements most found over the dentin after the irrigation with CHX and CHX-ET. Moreover, CHX and CHX-ET showed the highest incidence of CSL (p < .05), but without difference between them (p > .05), regardless of the post-space third. DW and CHX-PA showed similar incidence of CSL (p > .05). No difference on the incidence of open dentin tubules was found for any irrigation protocol and post-space third (p > .05). The use of 1% PA prior the post-space irrigation with CHX decrease the incidence of CSL. RESEARCH HIGHLIGHTS: The post-space irrigation with chlorhexidine results in the formation of chemical smear layer. Ethanol is not capable to remove the chemical smear layer. Peracetic acid is more effective to remove the chemical smear layer.
Collapse
Affiliation(s)
- Mariana Bena Gelio
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, São Paulo, Brazil
| | | | - Joissi Ferrari Zaniboni
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, São Paulo, Brazil
| | | | - João Felipe Besegato
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, São Paulo, Brazil
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, São Paulo, Brazil
| |
Collapse
|