Kristiansen CH, Tetteroo PM, Dobrolinska MM, Lauritzen PM, Velthuis BK, Greuter MJW, Suchá D, de Jong PA, van der Werf NR. Halved contrast medium dose coronary dual-layer CT-angiography - phantom study of tube current and patient characteristics. Int J Cardiovasc Imaging 2024; 40:931-940. [PMID: 38386192 PMCID: PMC11052773 DOI: 10.1007/s10554-024-03062-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Accepted: 02/03/2024] [Indexed: 02/23/2024]
Abstract
Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.
Collapse
Affiliation(s)
- C H Kristiansen
- Department of Diagnostic Imaging and Intervention, Akershus University Hospital, Lørenskog, Norway
- Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
| | - P M Tetteroo
- Department of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.
| | - M M Dobrolinska
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Division of Cardiology and Structural Heart Diseases, Medical University of Silesia in Katowice, Katowice, Poland
| | - P M Lauritzen
- Department of Diagnostic Imaging and Intervention, Akershus University Hospital, Lørenskog, Norway
- Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway
- Department of Radiology & Nuclear Medicine, Oslo University Hospital, Oslo, Norway
| | - B K Velthuis
- Department of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - M J W Greuter
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - D Suchá
- Department of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - P A de Jong
- Department of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | | |
Collapse
|
2
|
Dobrolinska MM, Jukema RA, van Velzen SGM, van Diemen PA, Greuter MJW, Prakken NHJ, van der Werf NR, Raijmakers PG, Slart RHJA, Knaapen P, Isgum I, Danad I. The prognostic value of visual and automatic coronary calcium -scoring from low dose CT-[15O]-water PET. Eur Heart J Cardiovasc Imaging 2024:jeae081. [PMID: 38525588 DOI: 10.1093/ehjci/jeae081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 02/28/2024] [Accepted: 03/06/2024] [Indexed: 03/26/2024] Open
Abstract
PURPOSE Firstly, to validate automatically and visually scored coronary artery calcium (CAC) on low dose CT (LDCT) scans with a dedicated calcium scoring CT (CSCT) scan. Secondly, to assess the added value of CAC scored from LDCT scans acquired during [15O]-water-PET myocardial perfusion imaging (MPI) on prediction of major adverse cardiac events (MACE). METHODS 572 consecutive patients with suspected coronary artery disease, who underwent [15O]-water-PET MPI with LDCT and a dedicated CSCT scan were included. In the reference CSCT scans, manual CAC scoring was performed, while LDCT scans were scored visually and automatically using deep learning approach. Subsequently, based on CAC score results from CSCT and LDCT scans, each patient's scan was assigned to one out of five cardiovascular risk groups (0; 1-100; 101-400; 401-1000; >1000) and the agreement in risk group classification between CSCT and LDCT scans was investigated. MACE was defined as a composite of all-cause death, nonfatal myocardial infarction, coronary revascularization, and unstable angina. RESULTS The agreement in risk group classification between reference CSCT manual scoring and visual/automatic LDCT scoring from LDCT was 0.66 (95% CI: 0.62-0.70) and 0.58 (95% CI: 0.53-0.62), respectively. Based on visual and automatic CAC scoring from LDCT scans, patients with CAC>100 and CAC>400, respectively, were at increased risk of MACE, independently of ischemic information from the [15O]-water-PET scan. CONCLUSIONS There is a moderate agreement in risk classification between visual and automatic CAC scoring from LDCT and reference CSCT scans. Visual and automatic CAC scoring from LDCT scans improve identification of patients at higher risk of MACE.
Collapse
Affiliation(s)
- M M Dobrolinska
- Medical Imaging Center, Departments of Radiology, Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB Groningen, The Netherlands
| | - R A Jukema
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, the Netherlands
| | - S G M van Velzen
- Department of Biomedical Engineering and Physics, Amsterdam UMC location University of Amsterdam, the Netherlands
- Informatics Institute, University of Amsterdam, the Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
| | - P A van Diemen
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, the Netherlands
| | - M J W Greuter
- Medical Imaging Center, Departments of Radiology, Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB Groningen, The Netherlands
- Department of Robotics and Mechatronics, Faculty of Electrical Engineering, Mathematics & Computer Science, University of Twente, P.O. Box 217, 7500 AE Enschede, Netherlands
| | - N H J Prakken
- Medical Imaging Center, Departments of Radiology, Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB Groningen, The Netherlands
| | - N R van der Werf
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - P G Raijmakers
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117
| | - R H J A Slart
- Medical Imaging Center, Departments of Radiology, Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB Groningen, The Netherlands
- Department of Biomedical Photonic Imaging, Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| | - P Knaapen
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, the Netherlands
| | - I Isgum
- Department of Biomedical Engineering and Physics, Amsterdam UMC location University of Amsterdam, the Netherlands
- Informatics Institute, University of Amsterdam, the Netherlands
- Amsterdam Cardiovascular Sciences, Amsterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC location University of Amsterdam, the Netherlands
| | - I Danad
- Department of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
3
|
van der Werf NR, Rodesch PA, Si-Mohamed S, van Hamersvelt RW, Greuter MJW, Leiner T, Boussel L, Willemink MJ, Douek P. Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study. Eur Radiol 2022; 32:3447-3457. [PMID: 34997284 DOI: 10.1007/s00330-021-08421-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 08/31/2021] [Accepted: 10/17/2021] [Indexed: 12/19/2022]
Abstract
OBJECTIVE The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS • In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. • Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. • For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.
Collapse
Affiliation(s)
- N R van der Werf
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands. .,Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
| | - P A Rodesch
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - S Si-Mohamed
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - R W van Hamersvelt
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - M J W Greuter
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - T Leiner
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - L Boussel
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - M J Willemink
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - P Douek
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
4
|
van der Werf NR, Willemink MJ, Willems TP, Vliegenthart R, Greuter MJW, Leiner T. Influence of heart rate on coronary calcium scores: a multi-manufacturer phantom study. Int J Cardiovasc Imaging 2017; 34:959-966. [PMID: 29285727 DOI: 10.1007/s10554-017-1293-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 12/19/2017] [Indexed: 12/20/2022]
Abstract
To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60-75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1-CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.
Collapse
Affiliation(s)
- N R van der Werf
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
- Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.
- Department of Clinical Physics, Albert Schweitzer Hospital, Albert Schweitzerplaats 25, 3318 AT, Dordrecht, The Netherlands.
- Department of Radiology, University Medical Center Utrecht, E01.132, PO Box 85500, 3508 GA, Utrecht, The Netherlands.
| | - M J Willemink
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - T P Willems
- Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - R Vliegenthart
- Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - M J W Greuter
- Department of Radiology, Center for Medical Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - T Leiner
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| |
Collapse
|
5
|
van der Werf NR, Willemink MJ, Willems TP, Greuter MJW, Leiner T. Influence of iterative reconstruction on coronary calcium scores at multiple heart rates: a multivendor phantom study on state-of-the-art CT systems. Int J Cardiovasc Imaging 2017; 34:947-957. [DOI: 10.1007/s10554-017-1292-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 12/19/2017] [Indexed: 10/18/2022]
|