1
|
P KK, Chiteti SR, Aileni VK, Babji S, Blackwelder WC, Kumar A, Vagha J, Nayak U, Mitra M, D N, Kar S, Yadav S, Naidu S, Mahantshetti N, Khalatkar V, Mohapatra S, Purthi PK, Sharma P, Kannan A, Dhongade RK, Prasad SD, Ella R, Vadrevu KM. Phase III randomized clinical studies to evaluate the immunogenicity, lot-to-lot consistency, and safety of ROTAVAC® liquid formulations (ROTAVAC 5C & 5D) and non-inferiority comparisons with licensed ROTAVAC® (frozen formulation) in healthy infants. Hum Vaccin Immunother 2023; 19:2278346. [PMID: 37968237 PMCID: PMC10760372 DOI: 10.1080/21645515.2023.2278346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 10/28/2023] [Indexed: 11/17/2023] Open
Abstract
The WHO pre-qualified rotavirus vaccine, ROTAVAC®, is derived naturally from the neonatal 116E rotavirus strain, and stored at -20°C. As refrigerator storage is preferable, immunogenicity and safety of liquid formulations kept at 2-8°C, having excipients to stabilize the rotavirus, with or without buffers, were compared with ROTAVAC® in different clinical studies. Study-1, the pivotal trial for this entire product development work, was a randomized, single-blind trial with two operationally seamless phases: (i) an exploratory phase involving 675 infants in which two formulations, ROTAVAC 5C (LnHRV-1.5 mL and LnHRV-2.0 mL) containing buffer and excipients to stabilize the virus against gastric acidity and temperature, were compared with ROTAVAC®. As the immune response of ROTAVAC 5C (LnHRV-2.0 mL) was non-inferior to ROTAVAC®, it was selected for (ii) confirmatory phase, involving 1,302 infants randomized 1:1:1:1 to receive three lots of LnHRV-2.0 mL, or ROTAVAC®. Primary objectives were the evaluation of non-inferiority and lot-to-lot consistency. The secondary objectives were to assess the safety and interference with the concomitant pentavalent vaccine. As it was separately established that buffers are not required for ROTAVAC®, in Study-2, the safety and immunogenicity of ROTAVAC 5D® (with excipients) were compared with ROTAVAC® and lot-to-lot consistency was assessed in another study. All lots elicited consistent immune responses, did not interfere with UIP vaccines, and had reactogenicity similar to ROTAVAC®. ROTAVAC 5C and ROTAVAC 5D® were immunogenic and well tolerated as ROTAVAC®. ROTAVAC 5D® had comparable immunogenicity and safety profiles with ROTAVAC® and can be stored at 2-8°C, leading to WHO pre-qualification.Clinical Trials Registration: Clinical Trials Registry of India (CTRI): CTRI/2015/02/005577CTRI/2016/11/007481 and CTRI/2019/03/017934.
Collapse
Affiliation(s)
- Krishna Kumari P
- Medical Affairs Department, Bharat Biotech International Limited, Hyderabad, India
| | | | - Vinay K. Aileni
- Medical Affairs Department, Bharat Biotech International Limited, Hyderabad, India
| | - Sudhir Babji
- Division of Gastrointestinal Sciences, Christian Medical College, Vellore, India
| | | | - Ashok Kumar
- Department of Paediatrics, Banaras Hindu University, Varanasi, India
| | - Jayant Vagha
- Department of Paediatrics, Datta Megha Institute of Medical Sciences, Wardha, India
| | - Uma Nayak
- Department of Paediatrics, GMERS Medical College, Vadodara, India
| | - Monjori Mitra
- Department of Paediatrics, Institute of Child Health, Kolkata, India
| | - Narayanaappa D
- Department of Paediatrics, Jagadguru Shivarathreeshwara Medical College, Mysore, India
| | - Sonali Kar
- Department of Community Medicine, Kalinga Institute of Medical Sciences, Bhubaneswar, India
| | - Sangeeta Yadav
- Department of Paediatrics, Maulana Azad Medical College, New Delhi, India
| | - Swamy Naidu
- Department of Paediatrics, King George Hospital, Vishakapatnam, India
| | - Niranjan Mahantshetti
- Department of Paediatrics, Dr. Prabhakar Kore Medical College & Hospital, Belgaum, India
| | | | | | - P. K. Purthi
- Department of Paediatrics, Sri Ganga Ram Hospital, New Delhi, India
| | - Pawan Sharma
- Department of Paediatrics, Maharshi Hospital & Research Centre, Jaipur, India
| | - A. Kannan
- Department of Paediatrics, Meenakshi Mission Hospital, Chennai, India
| | | | - Sai D. Prasad
- Medical Affairs Department, Bharat Biotech International Limited, Hyderabad, India
| | - Raches Ella
- Medical Affairs Department, Bharat Biotech International Limited, Hyderabad, India
| | | |
Collapse
|
2
|
Abstract
Nappy rash is a common problem in infants due to their thinner skin, wetness, heat and friction under cloth nappy, fecal enzymes and alkaline urine. The disposable diapers containing Super Absorbent Material (SAM) reduce the incidence of nappy rash. SAM quickly absorbs urine and keeps the skin dry. Also disposable diapers prevent fecal contamination by absorbing the urine and containing stools.
Collapse
Affiliation(s)
- Namita Singh
- Department of Pediatrics, Sir Ganga Ram Hospital, New Delhi, India
| | | | | | | |
Collapse
|