1
|
Layer YC, Isaak A, Mesropyan N, Kupczyk PA, Luetkens JA, Dell T, Attenberger UI, Kuetting D. Image quality of abdominal photon-counting CT with reduced contrast media dose: Evaluation of reduced contrast media protocols during the COVID19 pandemic supply shortage. Heliyon 2024; 10:e28142. [PMID: 38533048 PMCID: PMC10963370 DOI: 10.1016/j.heliyon.2024.e28142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 02/28/2024] [Accepted: 03/12/2024] [Indexed: 03/28/2024] Open
Abstract
Rationale and objectives Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.
Collapse
Affiliation(s)
- Yannik C. Layer
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Patrick A. Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Julian A. Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Tatjana Dell
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Ulrike I. Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
2
|
Layer YC, Mesropyan N, Kupczyk PA, Luetkens JA, Isaak A, Dell T, Ernst BP, Attenberger UI, Kuetting D. Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT. Sci Rep 2024; 14:497. [PMID: 38177651 PMCID: PMC10766624 DOI: 10.1038/s41598-023-50926-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 12/28/2023] [Indexed: 01/06/2024] Open
Abstract
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
Collapse
Affiliation(s)
- Yannik C Layer
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Patrick A Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Tatjana Dell
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Benjamin P Ernst
- Department of Otorhinolaryngology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
3
|
Layer YC, Mesropyan N, Kupczyk PA, Luetkens JA, Isaak A, Dell T, Attenberger UI, Kuetting D. Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT. Sci Rep 2023; 13:8955. [PMID: 37268675 DOI: 10.1038/s41598-023-35989-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 05/26/2023] [Indexed: 06/04/2023] Open
Abstract
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.
Collapse
Affiliation(s)
- Yannik C Layer
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Patrick A Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Tatjana Dell
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
4
|
Handke NA, Ollig A, Attenberger UI, Luetkens JA, Faron A, Pieper CC, Schmeel FC, Kupczyk PA, Meyer C, Kuetting D. Percutaneous transhepatic biliary drainage: a retrospective single-center study of 372 patients. Acta Radiol 2022; 64:1322-1330. [PMID: 36128748 DOI: 10.1177/02841851221127809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Complication rates in percutaneous transhepatic biliary drainage (PTBD) are non-uniform and vary considerably. In addition, the impact of peri-procedural risk factors is under-investigated. PURPOSE To compare success and complication rates of PTBD in patients with and without accompanying technical risk factors. MATERIAL AND METHODS A single-center retrospective study was conducted from January 2004 to December 2016. Patients receiving PTBD due to biliary obstruction or biliary leakage were included. Technical risk factors (non-distended bile ducts, ascites, obesity, anasarca, non-compliance) were assessed. Complications were classified according to the Society of Interventional Radiology. RESULTS In total, 372 patients were included (57.3% men, 42.7% women; mean age = 66 years). Overall, 466 PTBDs were performed. Of the patients, 70.1% presented with malignancy and biliary obstruction; 26.8% had benign biliary obstruction; 3.1% had biliary leakage. Technical risk factors were reported in 57 (15.3%) patients. Overall technical success of initial PTBD was 98.7%, primary technical success was 97.9%. In patients with non-dilatated bile ducts, primary technical success was 68.2%. Overall complication rate was 15.0% (8.1% major complications, 6.9% minor complications). Neither major nor minor complications were more frequent in patients with technical risk factors (P > 0.05). In left-sided PTBD, hemorrhage was more frequent (P = 0.015). Patients with malignancy were significantly more affected by drainage-related complications (P = 0.004; odds ratio = 2.03). The mortality rate was 0.5% (n = 2). CONCLUSION PTBD is a safe and effective method for the treatment of biliary obstruction and biliary leaks. Complication rates are low, even in procedures with risk factors.
Collapse
Affiliation(s)
- Nikolaus A Handke
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | - Annika Ollig
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | | | - Julian A Luetkens
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | - Anton Faron
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | - Claus C Pieper
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | | | - Patrick A Kupczyk
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | - Carsten Meyer
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| | - Daniel Kuetting
- Department of Radiology, 9374University Hospital Bonn, Bonn, Germany
| |
Collapse
|
5
|
Kupczyk PA, Attenberger UI, Meyer C, Luetkens JA, Kuetting D. Pilot Animal Study on Robotic-Assisted Endovascular Visceral Interventions. Cardiovasc Intervent Radiol 2022; 45:1207-1213. [PMID: 35764819 PMCID: PMC9307548 DOI: 10.1007/s00270-022-03204-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 06/08/2022] [Indexed: 11/30/2022]
Abstract
Purpose To evaluate technical feasibility and safety of common endovascular visceral interventions using a vascular robotic platform through preclinical study. Material and Methods The CorPath GRX Robotic System (Corindus Inc, Waltham, Massachusetts) was tested in an anesthetized pig for its ability to navigate various commercially available devices in the abdominal vasculature and to perform routine endovascular visceral procedures. After manually placing a guiding catheter in the celiac trunk, several visceral branches were probed with microcatheters and -wires under robotic assistance, and embolization with liquids (lipiodol), detachable coils and plugs were performed. Furthermore, the origin of the celiac trunk was stented before accessing the left hypogastric artery for pelvic embolization. Results All procedures were performed with technical success and without any complications. Navigating the catheters and wires via the steering console proved intuitive. Coil, plug and stent deployment were exclusively controlled by remote with remarkable precision and stability. Conclusion Robotic-assisted visceral embolization and stenting as well as pelvic embolization using the CorPath GRX System is feasible and safe. Application of the platform in the abdominal vasculature is demonstrated for the first time. Considering the precision and the potential for reducing the operator’s radiation exposure, further research in this area is highly encouraged to enable translation into clinical practice.
Collapse
Affiliation(s)
- Patrick A Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany. .,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Carsten Meyer
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
6
|
Mesropyan N, Kupczyk PA, Dold L, Praktiknjo M, Chang J, Isaak A, Endler C, Kravchenko D, Bischoff LM, Sprinkart AM, Pieper CC, Kuetting D, Jansen C, Attenberger UI, Luetkens JA. Assessment of liver cirrhosis severity with extracellular volume fraction MRI. Sci Rep 2022; 12:9422. [PMID: 35676399 PMCID: PMC9177655 DOI: 10.1038/s41598-022-13340-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 05/23/2022] [Indexed: 11/23/2022] Open
Abstract
We aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child–Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed. Clinical scores of liver disease severity were calculated. One-way analysis of variance (ANOVA) followed by Tukey’s multiple comparison test, Spearman’s correlation coefficient, and receiver operating characteristic (ROC) analysis were used for statistical analysis. In cirrhotic patients, hepatic native T1 increased depending on Child–Pugh class (620.5 ± 78.9 ms (Child A) vs. 666.6 ± 73.4 ms (Child B) vs. 828.4 ± 91.2 ms (Child C), P < 0.001). ECV was higher in cirrhotic patients compared to the controls (40.1 ± 11.9% vs. 25.9 ± 4.5%, P < 0.001) and increased depending of Child–Pugh class (33.3 ± 6.0% (Child A) vs. 39.6 ± 4.9% (Child B) vs. 52.8 ± 1.2% (Child C), P < 0.001). ECV correlated with Child–Pugh score (r = 0.64, P < 0.001). ECV allowed differentiating between Child–Pugh classes A and B, and B and C with an AUC of 0.785 and 0.944 (P < 0.001, respectively). The diagnostic performance of ECV for differentiating between Child–Pugh classes A and B, and B and C was higher compared to hepatic native T1 (AUC: 0.651 and 0.910) and MELD score (AUC: 0.740 and 0.795) (P < 0.05, respectively). MRI-derived ECV correlated with Child–Pugh score and had a high diagnostic performance for the discrimination of different Child–Pugh classes. ECV might become a valuable non-invasive biomarker for the assessment of liver cirrhosis severity.
Collapse
|
7
|
Endler CH, Ginzburg D, Isaak A, Faron A, Mesropyan N, Kuetting D, Pieper CC, Kupczyk PA, Attenberger UI, Luetkens JA. Diagnostic Benefit of MRI for Exclusion of Ligamentous Injury in Patients with Lateral Atlantodental Interval Asymmetry at Initial Trauma CT. Radiology 2021; 300:633-640. [PMID: 34184931 DOI: 10.1148/radiol.2021204187] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Cervical spine CT is regularly performed to exclude cervical spine injury during the initial evaluation of trauma patients. Patients with asymmetry of the lateral atlantodental interval (LADI) often undergo subsequent MRI to rule out ligamentous injuries. The clinical relevance of an asymmetric LADI and the benefit of additional MRI remain unclear. Purpose To evaluate the diagnostic benefit of additional MRI in patients with blunt trauma who have asymmetry of the LADI and no other cervical injuries. Materials and Methods Patients who underwent cervical spine CT during initial trauma evaluation between March 2017 and August 2019 were retrospectively evaluated. Those who underwent subsequent MRI because of LADI asymmetry of 1 mm or greater with no other signs of cervical injury were identified and reevaluated by two readers blinded to clinical data and initial study reports regarding possible ligamentous injuries. Results Among 1553 patients, 146 (9%) had LADI asymmetry of 1 mm or greater. Of these, 46 patients (mean age ± standard deviation, 39 years ± 22; 28 men; median LADI asymmetry, 2.4 mm [interquartile range, 1.8-3.1 mm]) underwent supplementary MRI with no other signs of cervical injury at initial CT. Ten of the 46 patients (22%) showed cervical tenderness at clinical examination, and 36 patients (78%) were asymptomatic. In two of the 46 patients (4%), MRI revealed alar ligament injury; both of these patients showed LADI asymmetry greater than 3 mm, along with cervical tenderness at clinical examination, and underwent treatment for ligamentous injury. In 13 of the 46 patients (28%), signal intensity alterations of alar ligaments without signs of rupture were observed. Four of these 13 patients (31%) were subsequently treated for ligamentous injury despite being asymptomatic. Conclusion Subsequent MRI following CT of the cervical spine in trauma patients with lateral atlantodental interval asymmetry may have diagnostic benefit only in symptomatic patients. In asymptomatic patients without proven cervical injuries, subsequent MRI showed no diagnostic benefit and may even lead to overtreatment. © RSNA, 2021 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Christoph H Endler
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Daniel Ginzburg
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Alexander Isaak
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Anton Faron
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Narine Mesropyan
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Daniel Kuetting
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Claus C Pieper
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Patrick A Kupczyk
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Ulrike I Attenberger
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| | - Julian A Luetkens
- From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany (C.H.E., D.G., A.I., A.F., N.M., D.K., C.C.P., P.A.K., U.I.A., J.A.L.); and Quantitative Imaging Laboratory Bonn (QILaB), Bonn, Germany (C.H.E., A.I., A.F., N.M., D.K., P.A.K., J.A.L.)
| |
Collapse
|
8
|
Endler CHJ, Faron A, Isaak A, Katemann C, Mesropyan N, Kupczyk PA, Pieper CC, Kuetting D, Hadizadeh DR, Attenberger UI, Luetkens JA. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences. ROFO-FORTSCHR RONTG 2021; 193:813-821. [PMID: 33535259 DOI: 10.1055/a-1337-3351] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
PURPOSE Compressed sensing (CS) is a method to accelerate MRI acquisition by acquiring less data through undersampling of k-space. In this prospective study we aimed to evaluate whether a three-dimensional (3D) isotropic proton density-weighted fat saturated sequence (PDwFS) with CS can replace conventional multidirectional two-dimensional (2D) sequences at 1.5 Tesla. MATERIALS AND METHODS 20 patients (45.2 ± 20.2 years; 10 women) with suspected internal knee damage received a 3D PDwFS with CS acceleration factor 8 (acquisition time: 4:11 min) in addition to standard three-plane 2D PDwFS sequences (acquisition time: 4:05 min + 3:03 min + 4:46 min = 11:54 min) at 1.5 Tesla. Scores for homogeneity of fat saturation, image sharpness, and artifacts were rated by two board-certified radiologists on the basis of 5-point Likert scales. Based on these ratings, an overall image quality score was generated. Additionally, quantitative contrast ratios for the menisci (MEN), the anterior (ACL) and the posterior cruciate ligament (PCL) in comparison with the popliteus muscle were calculated. RESULTS The overall image quality was rated superior in 3D PDwFS compared to 2D PDwFS sequences (14.45 ± 0.83 vs. 12.85 ± 0.99; p < 0.01), particularly due to fewer artifacts (4.65 ± 0.67 vs. 3.65 ± 0.49; p < 0.01) and a more homogeneous fat saturation (4.95 ± 0.22 vs. 4.55 ± 0.51; p < 0.01). Scores for image sharpness were comparable (4.80 ± 0.41 vs. 4.65 ± 0.49; p = 0.30). Quantitative contrast ratios for all measured structures were superior in 3D PDwFS (MEN: p < 0.05; ACL: p = 0.06; PCL: p = 0.33). In one case a meniscal tear was only diagnosed using multiplanar reformation of 3D PDwFS, but it would have been missed on standard multiplanar 2D sequences. CONCLUSION An isotropic fat-saturated 3D PD sequence with CS enables fast and high-quality 3D imaging of the knee joint at 1.5 T and may replace conventional multiplanar 2D sequences. Besides faster image acquisition, the 3D sequence provides advantages in small structure imaging by multiplanar reformation. KEY POINTS · 3D PDwFS with compressed sensing enables knee imaging that is three times faster compared to multiplanar 2D sequences. · 3D PDwFS with compressed sensing provides high-quality knee imaging at 1.5 T. · Isotropic 3D sequences provide advantages in small structure imaging by using multiplanar reformations. CITATION FORMAT · Endler CH, Faron A, Isaak A et al. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences. Fortschr Röntgenstr 2021; 193: 813 - 821.
Collapse
Affiliation(s)
- Christoph H-J Endler
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Anton Faron
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Alexander Isaak
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | | | - Narine Mesropyan
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Patrick A Kupczyk
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Claus C Pieper
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Daniel Kuetting
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| | - Dariusch R Hadizadeh
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Ulrike I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany
| | - Julian A Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Germany.,Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Germany
| |
Collapse
|
9
|
Kupczyk PA, Mesropyan N, Isaak A, Endler C, Faron A, Kuetting D, Sprinkart AM, Mädler B, Thomas D, Attenberger UI, Luetkens JA. Quantitative MRI of the liver: Evaluation of extracellular volume fraction and other quantitative parameters in comparison to MR elastography for the assessment of hepatopathy. Magn Reson Imaging 2020; 77:7-13. [PMID: 33309923 DOI: 10.1016/j.mri.2020.12.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 11/27/2020] [Accepted: 12/06/2020] [Indexed: 12/22/2022]
Abstract
BACKGROUND Chronic liver diseases pose a major health problem worldwide, while common tests for diagnosis and monitoring of diffuse hepatopathy have considerable limitations. Preliminary data on the quantification of hepatic extracellular volume fraction (ECV) with magnetic resonance imaging (MRI) for non-invasive assessment of liver fibrosis are encouraging, with ECV having the potential to overcome several of these constraints. PURPOSE To clinically evaluate ECV provided by quantitative MRI for assessing the severity of liver disease. MATERIALS AND METHODS In this prospective study, multiparametric liver MRI, including T1 mapping and magnetic resonance elastography (MRE), was performed in subjects with and without hepatopathy between November 2018 and October 2019. T1, T2, T2*, proton density fat fraction and stiffness were extracted from parametric maps by regions of interest and ECV was calculated from T1 relaxometries. Serum markers of liver disease were obtained by clinical database research. For correlation analysis, Spearman rank correlation was used. ROC analysis of serum markers and quantitative MRI data for discrimination of liver cirrhosis was performed with MRE as reference standard. RESULTS 109 participants were enrolled (50.7 ± 16.1 years, 61 men). ECV, T1 and MRE correlated significantly with almost all serum markers of liver disease, with ECV showing the strongest associations (up to r = 0.67 with MELD, p < 0.01). ECV and T1 correlated with MRE (0.75 and 0.73, p < 0.01 each). ECV (AUC 0.89, cutoff 32.2%, sensitivity 85%, specificity 87%) and T1 mapping (AUC 0.85, cutoff 592.5 ms, sensitivity 83%, specificity 75%) featured good performances in detection of liver cirrhosis with only ECV performing significantly superior to model of end stage liver disease (MELD), AST/ALT ratio and international normalized ratio (p < 0.01, respectively). CONCLUSION Quantification of hepatic extracellular volume fraction with MRI is suitable for estimating the severity of liver disease when using MRE as the standard of reference. It represents a promising tool for non-invasive assessment of liver fibrosis and cirrhosis.
Collapse
Affiliation(s)
- P A Kupczyk
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany.
| | - N Mesropyan
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - A Isaak
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - C Endler
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - A Faron
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - D Kuetting
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - A M Sprinkart
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - B Mädler
- Philips Healthcare, Hamburg, Germany
| | - D Thomas
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - U I Attenberger
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| | - J A Luetkens
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Quantitative Imaging Lab Bonn (QILaB), Venusberg-Campus 1, 53127 Bonn, Germany
| |
Collapse
|
10
|
Kupczyk PA, Fischer S, Praktiknjo M, Stein J, Müller SC, Meyer C. [Life-threatening bleeding from ileal conduit venous varices in a patient with portal hypertension]. Urologe A 2018; 58:41-44. [PMID: 30539203 DOI: 10.1007/s00120-018-0824-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Life-threatening bleeding from portosystemic varices is a feared complication of portal hypertension. Particularly, varices in atypical locations-so-called ectopic varices-pose a challenge for diagnosis and therapy. In the present article, we describe the case of a patient with liver cirrhosis and recurrent bleeding from an ileal conduit resulting from peristomal varicosis. The difficult and hence delayed diagnosis led to a life-threatening hemorrhage that was successfully treated with interventional radiological variceal embolization and TIPS (transjugular intrahepatic portosystemic shunt) implantation.
Collapse
Affiliation(s)
- P A Kupczyk
- Radiologische Klinik, Universitätsklinikum Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Deutschland.
| | - S Fischer
- Radiologische Klinik, Universitätsklinikum Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Deutschland
| | - M Praktiknjo
- Medizinische Klinik und Poliklinik I, Universitätsklinikum Bonn, Bonn, Deutschland
| | - J Stein
- Klinik und Poliklinik für Urologie und Kinderurologie, Universitätsklinikum Bonn, Bonn, Deutschland
| | - S C Müller
- Klinik und Poliklinik für Urologie und Kinderurologie, Universitätsklinikum Bonn, Bonn, Deutschland
| | - C Meyer
- Radiologische Klinik, Universitätsklinikum Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Deutschland
| |
Collapse
|
11
|
Doerner J, Kupczyk PA, Wilsing M, Luetkens JA, Storm K, Fimmers R, Hickethier T, Eichhorn L, Naehle CP, Schild HH, Werner N, Nickenig G, Ghanem A. Cerebral white matter lesion burden is associated with the degree of aortic valve calcification and predicts peri-procedural cerebrovascular events in patients undergoing transcatheter aortic valve implantation (TAVI). Catheter Cardiovasc Interv 2017; 91:774-782. [PMID: 28547872 DOI: 10.1002/ccd.27122] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Revised: 04/01/2017] [Accepted: 04/23/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVES To investigate the impact of aortic valve calcification and brain morphology on acute peri-procedural cerebrovascular events (CVEs) in patients undergoing transcatheter aortic valve implantation (TAVI). BACKGROUND Aortic valve calcification and stenosis can be assessed with echocardiography. Cerebral magnetic resonance imaging (MRI) depicts and quantifies morphological signs of hypoperfusion and vascular embolism, which is of special interest in patients with severe aortic stenosis. Furthermore, subjects who undergo TAVI are prone to suffer of clinically silent peri-procedural CVEs. METHODS A total of 119 patients referred to TAVI were investigated for aortic valve calcification using trans-esophageal echocardiography. Cerebral MRI prior to and immediate after implantation was performed in all patients using a dedicated scan protocol. Prior to TAVI, brain morphology was characterized. Post TAVI, brains were investigated for the onset of acute peri-procedural CVEs using diffusion weighted imaging (DWI). RESULTS Seventy-eight patients (65.5%) revealed acute peri-procedural CVEs on MRI after TAVI with a favor of the left hemisphere (57.5%). The degree of valve calcification was associated with peri-procedural CVEs. Patients with a high WML burden had an increased risk for CVEs ((OR) 2.36 (95% CI: 1.09-5.15; P = 0.037)), especially when distributed periventricular ((OR: 3.27; 95% CI: 1.47-7.26; P = 0.0038)). CONCLUSION In patients undergoing TAVI, the degree of aortic valve calcification and periventricular WML burden were correlated with acute peri-procedural CVEs. Future studies are needed to evaluate their independent value for the long-term clinical outcome.
Collapse
Affiliation(s)
- Jonas Doerner
- Department of Radiology, University of Bonn, Bonn, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital of Cologne, Cologne, Germany
| | | | - Marius Wilsing
- Department of Cardiology, University Hospital of Bonn, Bonn, Germany
| | | | - Klaus Storm
- Department of Cardiology, University Hospital of Bonn, Bonn, Germany
| | - Rolf Fimmers
- Department of Medical Biometry, Informatics, and Epidemiology, University of Bonn, Bonn, Germany
| | - Tilman Hickethier
- Department of Diagnostic and Interventional Radiology, University Hospital of Cologne, Cologne, Germany
| | - Lars Eichhorn
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Bonn, Bonn, Germany
| | - Claas P Naehle
- Department of Radiology, University of Bonn, Bonn, Germany.,Division of Radiology and Nuclear Medicine, Kantonsspital St. Gallen, St. Gallen, Switzerland
| | - Hans H Schild
- Department of Radiology, University of Bonn, Bonn, Germany
| | - Nikos Werner
- Department of Cardiology, University Hospital of Bonn, Bonn, Germany
| | - Georg Nickenig
- Department of Cardiology, University Hospital of Bonn, Bonn, Germany
| | - Alexander Ghanem
- Department of Cardiology, University Hospital of Bonn, Bonn, Germany.,Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| |
Collapse
|
12
|
Kupczyk PA, Willinek WA, Hadizadeh DR, Traeber F, Gieseke J, Meyer C, Schild HH, Kukuk GM. Abdominal vasculature in dynamic contrast-enhanced liver MRI at 3.0T: an intraindividual comparative study using gadoxetate disodium and gadofosveset trisodium. Magn Reson Imaging 2015; 33:1258-1266. [PMID: 26271178 DOI: 10.1016/j.mri.2015.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Accepted: 08/05/2015] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To intraindividually compare gadoxetate disodium and gadofosveset trisodium regarding vessel contrast, image quality and vessel delineation in dynamic contrast-enhanced liver MRI at 3.0T. METHODS Twelve patients underwent 3.0T MRI twice (24 examinations) with a single dose of gadoxetate disodium and gadofosveset trisodium, respectively. Signal intensity in abdominal vessels and tissue was determined. Vessel-to-background ratio (VBR) was calculated for each vessel and dynamic phase. All images were evaluated by two radiologists regarding image quality, vessel delineation and anatomic variants or pathologies with digital subtraction angiography as the standard of reference. RESULTS Gadofosveset trisodium demonstrated a significantly higher VBR compared to gadoxetate disodium (arterial phase: 0.57±0.12 [SD] vs. 0.46±0.19; portal venous phase: 0.51±0.11 vs. 0.37±0.14; equilibrium phase: 0.48±0.10 vs. 0.31±0.13; p≤0.01). Image quality and vessel delineation were rated equal or better for gadofosveset trisodium in all cases. These differences were not significant for most vessel segments. All anatomic variants were correctly identified by both readers for both contrast agents. CONCLUSIONS Although gadofosveset trisodium provides a significantly higher vessel contrast at 3.0T, gadoxetate disodium is equivalent by qualitative measurements. Thus, gadoxetate-enhanced liver MRI at 3.0T enables reliable assessment of the upper abdominal vasculature with the additional benefit of hepatobiliary imaging.
Collapse
Affiliation(s)
- Patrick A Kupczyk
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Winfried A Willinek
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Dariusch R Hadizadeh
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Frank Traeber
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Juergen Gieseke
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Carsten Meyer
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Hans H Schild
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| | - Guido M Kukuk
- Department of Radiology - University of Bonn, Sigmund-Freud-Straße 25, 53127, Bonn, Germany.
| |
Collapse
|
13
|
Luetkens JA, Kupczyk PA, Doerner J, Fimmers R, Willinek WA, Schild HH, Kukuk GM. Respiratory motion artefacts in dynamic liver MRI: a comparison using gadoxetate disodium and gadobutrol. Eur Radiol 2015; 25:3207-13. [PMID: 25903709 DOI: 10.1007/s00330-015-3736-x] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 01/20/2015] [Accepted: 03/23/2015] [Indexed: 12/29/2022]
Abstract
OBJECTIVES Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol. METHODS Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons. RESULTS Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4%] vs. 7/460 [1.5%]; p = 0.341). CONCLUSIONS Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts. KEY POINTS • Gadobutrol and gadoxetate disodium showed comparable motion scores in dynamic phase imaging. • The incidence of severe motion artefacts was pronounced in arterial phase imaging. • Adverse respiratory side effects were not recorded in 115 examinations with gadoxetate disodium.
Collapse
Affiliation(s)
- Julian A Luetkens
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Patrick A Kupczyk
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Jonas Doerner
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Rolf Fimmers
- Department of Medical Biometry, Informatics, and Epidemiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Winfried A Willinek
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Hans H Schild
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany
| | - Guido M Kukuk
- Department of Radiology, University of Bonn, Sigmund-Freud-Str. 25, 53127, Bonn, Germany.
| |
Collapse
|