Baudo M, Sicouri S, Yamashita Y, Ridwan K, Kadri A, Goldman SM, Rodriguez R, Gnall EM, Coady PM, Reardon MJ, Gada H, Gray WA, Ramlawi B. Improved Hemodynamics with Self-Expanding Compared to Balloon Expandable Transcatheter Aortic Valve Implantation in Small Annulus Patients: A Propensity-Matched Analysis. Am J Cardiol 2024:S0002-9149(24)00264-9. [PMID: 38636627 DOI: 10.1016/j.amjcard.2024.03.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 02/28/2024] [Accepted: 03/30/2024] [Indexed: 04/20/2024]
Abstract
Patients with small aortic annuli (SAA) pose a challenge in aortic valve replacement patients due to potential for prosthesis-patient mismatch (PPM). The objective of this study was to compare clinical and hemodynamic outcomes of self-expandable valves (SEV) versus balloon-expandable valves (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance baseline characteristics. Bioprosthesis valve dysfunction (BVD) was based on modified Valve Academic Research Consortium 3 (VARC-3) criteria. A total of 1170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at CT scan and matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p<0.001), higher grades of mitral regurgitation (p=0.029), and lower ejection fraction (p<0.043) in BEV when compared to SEV. At follow-up, significant differences favoring the SEV group regarding BVD were observed (p=0.002), especially in terms of severe PPM (p=0.046), and at least moderate structural valve deterioration (p=0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients and PPM (including severe) compared to SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the two groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.
Collapse
Affiliation(s)
- Massimo Baudo
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, USA; Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA.
| | - Serge Sicouri
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, USA
| | - Yoshiyuki Yamashita
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, USA; Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Khalid Ridwan
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, USA
| | - Amer Kadri
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Scott M Goldman
- Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Roberto Rodriguez
- Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Eric M Gnall
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Paul M Coady
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Michael J Reardon
- Department of Cardiovascular Surgery, Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA
| | - Hemal Gada
- Structural Heart Program, University of Pittsburgh Medical Center Pinnacle Health, Harrisburg, Pennsylvania, USA
| | - William A Gray
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| | - Basel Ramlawi
- Department of Cardiac Surgery Research, Lankenau Institute for Medical Research, Main Line Health, Wynnewood, PA, USA; Department of Cardiac Surgery, Lankenau Heart Institute, Main Line Health, Wynnewood, PA, USA
| |
Collapse
|
2
|
Yamashita Y, Sicouri S, Dokollari A, Senzai M, Rodriguez R, Gnall EM, Coady PM, Jarrett H, Abramson SV, Hawthorne KM, Goldman SM, Gray WA, Ramlawi B. Impact of mitral stenosis on early and late outcomes of transcatheter aortic valve replacement for aortic stenosis: a single-center analysis. J Invasive Cardiol 2024. [PMID: 38422528 DOI: 10.25270/jic/23.00307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
OBJECTIVES To assess the impact of concomitant mitral stenosis (MS) on early and late outcomes of transcatheter aortic valve replacement (TAVR) for aortic stenosis. METHODS This study involved 952 patients undergoing TAVR for severe tricuspid aortic stenosis. The patients were classified into 3 groups: without MS, with progressive MS, and severe MS (mitral valve area ≤ 1.5 cm2). Clinical outcomes between these groups were compared. RESULTS The median age of the overall cohort was 82 years, and patients in the progressive (n = 49) and severe (n = 24) MS groups were more likely to be female than those in the no-MS group (n = 879). Periprocedural mortality rate was lowest in the no-MS group (1.8%) compared with the progressive (4.1%) and severe (4.2%) MS groups, which were not significantly different (P = .20). During 5 years of follow-up (median: 27, range: 0-72 months), there was no significant difference in all-cause mortality (log-rank P = .99), a composite of all-cause mortality or rehospitalization for heart failure (log-rank P = .84), or cardiovascular death (log-rank P = .57) between groups. Although crude analysis showed a significant difference in rehospitalization for heart failure in the severe MS group compared with the no-MS group (P = .049), the difference was not significant in the multivariate analysis (adjusted hazard ratio: 1.36 [95% CI, 0.66-2.80], P = .41). CONCLUSIONS TAVR can be safely performed in patients with severe tricuspid aortic stenosis and concomitant MS, with early and mid-term outcomes comparable to those in patients without MS.
Collapse
Affiliation(s)
- Yoshiyuki Yamashita
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA.
| | - Serge Sicouri
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Aleksander Dokollari
- Department of Cardiac Surgery, St. Boniface Hospital, University of Manitoba, Winnipeg, MB, Canada
| | - Mikiko Senzai
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Roberto Rodriguez
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Eric M Gnall
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Paul M Coady
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Harish Jarrett
- Department of Cardiovascular Disease, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Sandra V Abramson
- Department of Cardiovascular Disease, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Katie M Hawthorne
- Department of Cardiovascular Disease, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Scott M Goldman
- Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - William A Gray
- Department of Interventional Cardiology, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| | - Basel Ramlawi
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA
| |
Collapse
|
3
|
Memon S, Goldman S, Rodriguez R, Ramlawi B, Coady PM, Gnall EM. Alternative Application Technique for the MANTA Vascular Closure Device for Percutaneous Large-Bore Arterial Access Closure: The Fluoroscopic DOT Technique. J Endovasc Ther 2023; 30:885-891. [PMID: 35766367 DOI: 10.1177/15266028221105187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Vascular complications are a cause of increased morbidity and mortality when performing percutaneous procedures requiring large-bore arterial access. MANTA vascular closure device (VCD) is currently the only large-bore VCD using an intraluminal foot plate and an extraluminal collagen plug. The traditional depth locator approach might be compromised in; emergent cases without the required measurements, cases of hematoma formation, or other patient, procedure, or operator-specific variables. Furthermore, this technique can be used for postclosure in cases without the required measurement of depth. We describe vascular outcomes using fluoroscopy (fluoroscopic DOT technique) rather than traditional depth locator approach for vascular closure with the MANTA VCD. METHODS Fifty patients who underwent transcatheter aortic valve implantation (TAVI) were retrospectively analyzed using fluoroscopic DOT technique with 18F MANTA VCD between May and August 2021. All patients >18 years of age who qualified for transfemoral TAVI were included. Access was obtained with ultrasound guidance with vessel diameter of at least > 6 mm and free from anterior vessel wall calcification. Patient related factors and primary outcomes of access site bleeding and acute flow-limited limb ischemia requiring intervention were prospectively analyzed. Furthermore, 1 patient who failed hemostasis with suture-mediated VCD had successful hemostasis with fluoroscopic DOT technique as dry postclosure after balloon aortic valvuloplasty. RESULTS In total, 50 patients were analyzed with a mean age of 81 years and majority were male (56%). Majority had comorbidities of hypertension (88%) and hyperlipidemia (94%), 24% had peripheral arterial disease, 38% coronary artery disease, and 58% were former smokers. Importantly, 40% were obese with an average body mass index (BMI) of 29 kg/m2. There were no bleeding or ischemic limb complications post MANTA VCD deployment using the fluoroscopic DOT technique. Furthermore, none of the patients required peripheral intervention from index procedure to 1 month post verified during their 1-month post TAVR follow-up. CONCLUSION Fluoroscopic DOT technique using the MANTA VCD is highly reproducible and allows hemostasis in a predictable manner for procedures requiring large-bore arterial access in the absence of MANTA depth measurement.
Collapse
Affiliation(s)
- Sehrish Memon
- Division of Cardiovascular Diseases, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| | - Scott Goldman
- Division of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| | - Roberto Rodriguez
- Division of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| | - Basel Ramlawi
- Division of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| | - Paul M Coady
- Division of Cardiovascular Diseases, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| | - Eric M Gnall
- Division of Cardiovascular Diseases, Lankenau Medical Center, Lankenau Institute of Medical Research, Wynnewood, PA, USA
| |
Collapse
|
4
|
Sá MP, Van den Eynde J, Jacquemyn X, Erten O, Rodriguez R, Goldman S, Coady PM, Gnall E, Gray WA, Jarrett H, Abramson SV, Clavel MA, Pibarot P, Ramlawi B. Computed tomography-derived membranous septum length as predictor of conduction abnormalities and permanent pacemaker implantation after TAVI: A meta-analysis of observational studies. Catheter Cardiovasc Interv 2023; 101:1203-1213. [PMID: 37070459 DOI: 10.1002/ccd.30666] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 03/13/2023] [Accepted: 04/08/2023] [Indexed: 04/19/2023]
Abstract
BACKGROUND Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS Study-level meta-analysis of studies published by September 30, 2022. RESULTS Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.
Collapse
Affiliation(s)
- Michel Pompeu Sá
- Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | | | - Xander Jacquemyn
- Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
| | - Ozgun Erten
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| | - Roberto Rodriguez
- Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Scott Goldman
- Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Paul M Coady
- Department of Interventional Cardiology, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Eric Gnall
- Department of Interventional Cardiology, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - William A Gray
- Department of Interventional Cardiology, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Harish Jarrett
- Department of Cardiovascular Imaging, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Sandra V Abramson
- Department of Cardiovascular Imaging, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
| | - Marie-Annick Clavel
- Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec City, Québec, Canada
- Department of Medicine, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Philippe Pibarot
- Centre de Recherche de l'Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec City, Québec, Canada
- Department of Medicine, Faculty of Medicine, Université Laval, Québec City, Québec, Canada
| | - Basel Ramlawi
- Department of Cardiothoracic Surgery, Lankenau Medical Center, Lankenau Heart Institute, Main Line Health, Wynnewood, Pennsylvania, USA
- Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA
| |
Collapse
|
5
|
Maqsood K, Badri M, Burke JF, Saeed W, Mirrani G, Sarwar N, Kusick J, McGeehin FC, Coady PM, Sardar MR. Spontaneous coronary dissection presenting with reperfusion arrhythmia: A case report. ACTA ACUST UNITED AC 2013. [DOI: 10.4236/crcm.2013.23058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
6
|
Shapiro TA, Coady PM. Diagnostic testing of cardiac function. Occup Med 1997; 12:513-23. [PMID: 9298497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The electrocardiogram's value in detecting atrial abnormalities, ventricular hypertrophy, and myocardial injury is described, with attention to ambulatory monitoring and exercise stress testing. Perfusion imaging, assessment of resting cardiac function with echocardiography, and other techniques also are addressed.
Collapse
Affiliation(s)
- T A Shapiro
- Hospital of the University of Pennsylvania, Philadelphia, USA
| | | |
Collapse
|