1
|
Song GY, Zhao YW, Du GY, Chen Y, Wang MY, Teng SY, Luo T, Zhou Z, Niu GN, Zhao ZY, Lu ZN, Wu YJ. [Single center experience of transcatheter aortic valve replacement with a simplified operative protocol]. Zhonghua Xin Xue Guan Bing Za Zhi 2022; 50:563-569. [PMID: 35705465 DOI: 10.3760/cma.j.cn112148-20210728-00626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Objective: To summarize the single center experience of transcatheter aortic valve replacement (TAVR) with a simplified operative protocol. Methods: Consecutive patients who underwent transfemoral TAVR (TF-TAVR) from July 2020 to December 2020 in Fuwai Hospital were retrospectively analyzed. We compared the baseline characteristic, procedure information, 30-day follow-up outcomes of the patients who underwent TF-TAVR without the simplified operative protocol (routine group) or with the simplified operative protocol (simplified protocol group). Results: 93 patients were collected, 42 patients belonging to routine group, 51 patients belonging to simplified protocol group. In simplified protocol group, there were 51 patients planned to use ultrasound-guided femoral access puncture, procedure was successful in all 51 patients (100%). There were 49 patients planned to use the radial artery as the secondary access, procedure was successful in 45 patients (92%). There were 48 patients planned to use the strategy of avoidance of urinary catheter, this strategy was achieved in 35 patients (73%). There were 12 patients planned to use the left ventricular guidewire to pace, procedure was successful in 11 patients (92%). There were no differences in baseline characteristics, major clinical endpoints and 30-day follow-up outcomes between the two groups. Meanwhile, the procedure time ((62.5±17.9)min vs. (78.3±16.7)min, P<0.001), operation room time ((133.7±25.1)min vs. (159.2±42.6)min, P<0.001), X-ray exposure time ((17.2±6.5)min vs. (20.2±7.7)min, P=0.027) were significantly shorten in simplified protocol group compared with the routine group. Conclusion: Our study results indicate that the simplified operative protocol of TF-TAVR is as effective and safe as the routine operative protocol, meanwhile using the simplified operative protocol can significantly increase the operative efficiency of TF-TAVR.
Collapse
Affiliation(s)
- G Y Song
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y W Zhao
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - G Y Du
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y Chen
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - M Y Wang
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - S Y Teng
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - T Luo
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Z Zhou
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - G N Niu
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Z Y Zhao
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Z N Lu
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y J Wu
- Coronary Artery Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| |
Collapse
|
2
|
Song GY, Liu XM, Teng SY, Luo T, Wang MY, Wang YB, Zhou Z, Niu GN, Qian J, Wu YJ. [Left ventricular guidewire pacing during transcatheter aortic valve replacement]. Zhonghua Xin Xue Guan Bing Za Zhi 2021; 49:461-466. [PMID: 34034379 DOI: 10.3760/cma.j.cn112148-20210401-00294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the safety and efficacy of left ventricular guidewire pacing during transcatheter aortic valve replacement (TAVR). Methods: This is a retrospective study. Thirteen patients, who underwent TAVR with left ventricular guidewire pacing from October 2019 to December 2019 in Fuwai Hospital, were included. Clinical data and operational procedure data of the patients were collected. Changes in blood pressure and electrocardiogram were observed during operations. Ascending aorta angiography was performed to evaluate the regurgitation of aortic valve after valve implantion. The incidence of major adverse cardiac events during hospitalization and at 3-months after discharge was recorded. Results: There were 7 male and 6 female patients in this cohort,and age was (73.8±8.3) years old. Among the 13 patients, 9 were tricuspid aortic valves, 3 were bicuspid aortic valves, and 1 was degenerated bioprosthetic surgical aortic valve. TAVR were successfully performed in all of the 13 cases using pacing through the left ventricular guidewire. During balloon dilation, the blood pressure decreased to below 60 mmHg (1 mmHg=0.133 kPa) after 180 beats/min pacing, and the valve release process was smooth and the position was stable. The results of aortography showed that there was no regurgitation in 7 cases, mild regurgitation in 5 cases and moderate regurgitation in 1 case. Three patients required temporary pacing during the procedure due to complete heart block, among whom 1 patient was implanted with permanent pacemaker during hospitalization, and the other 2 patients recovered within 24 hours after operation. In another case, there was no significant change of electrocardiogram during the operation, and complete heart block occurred 10 days after the operation, and treated with permanent pacemaker. The other 10 patients began to carry out bedside activities and rehabilitation training 24 hours after operation. There was no death, myocardial infarction, stroke and other major adverse cardiac events during hospitalization and at 3-month follow-up after discharge. Conclusion: Left ventricular guidewire pacing is a safe and effective strategy for TAVR.
Collapse
Affiliation(s)
- G Y Song
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - X M Liu
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - S Y Teng
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - T Luo
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - M Y Wang
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y B Wang
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Z Zhou
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - G N Niu
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - J Qian
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y J Wu
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| |
Collapse
|
3
|
Wang MY, Song GY, Niu GN, Ye YQ, Wang YB, Luo T, Teng SY, Wu YJ. [Feasibility of single-stage stent implantation following rotational atherectomy combined with TAVR]. Zhonghua Xin Xue Guan Bing Za Zhi 2021; 49:66-70. [PMID: 33429489 DOI: 10.3760/cma.j.cn112148-20200226-00129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To explore the feasibility of the single-stage stent implantation following rotational atherectomy combined with transcatheter aortic valve replacement (TAVR) in treating patients with severe aortic stenosis(AS) and severe calcified coronary artery stenosis. Methods: Three patients who received single-stage stent implantation following rotational atherectomy combined with TAVR in Fuwai hospital from April to October 2019 were included in this retrospective analysis. Clinical and anatomical features (including echocardiography and aortic CT) of the patients were collected, efficacy and safety of this operation strategy were observed and 6 months follow up results were summarized. Results: Three patients (2 females, 66-80 years old) were included. The mean Society of Thoracic Surgeons (STS) risk score was 7.8%. The mean maximum velocity of aortic valve was 4.4 m/s, the mean transvalvular pressure gradient was 53.2 mmHg (1 mmHg=0.133 kPa), mean left ventricular ejection fraction (LVEF) was 48.6%. All three patients had severe calcified coronary artery stenosis: left anterior descending artery (LAD, n=2) and left main coronary artery (LM, n=1), requiring rotary grinding. The mean SYNTAX score was 20. All the procedures were performed through transfemoral access. After aortic valve crossing, all coronary lesions were successfully treated with stent implantation following rotational atherectomy, transfemoral TAVR was then immediately performed with a self-expandable Venus-A valve. One patient underwent"valve-in-valve"implantation due to the high-implantation position of the first valve. The procedures were completed without complications in all the three patients. The immediate effect was satisfactory. Echocardiography results showed that the mean maximum velocity of aortic valve was 2.1 m/s, mean gradient was 9.3 mmHg, and mean LVEF was 59% after the procedure. There was no death and revascularization during the 6 months follow-up. Conclusion: In patients with severe calcified coronary artery and severe AS with high risk of cardiac surgery, the single-stage stent implantation following rotational atherectomy combined with TAVR is feasible and results are satisfactory in this patient cohort.
Collapse
Affiliation(s)
- M Y Wang
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - G Y Song
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - G N Niu
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y Q Ye
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y B Wang
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - T Luo
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - S Y Teng
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Y J Wu
- Structure Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| |
Collapse
|
4
|
Wang MY, Song GY, Wang Y, Niu GN, Zhang Q, Zhou Z, Zhang H, Zhang WJ, Luo T, Teng SY, Yang YJ, Wu YJ. [Impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement in patients with native bicuspid aortic valve stenosis]. Zhonghua Xin Xue Guan Bing Za Zhi 2018; 46:629-634. [PMID: 30139014 DOI: 10.3760/cma.j.issn.0253-3758.2018.08.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement (TAVR) in bicuspid aortic valve patients. Methods: Clinical data of 40 patients with native bicuspid aortic valve stenosis who underwent TAVR using the self-expandable prosthesis (the Venus A-valve) from 2014 to 2017 in Fuwai Hospital was retrospectively analyzed. The patients were divided into non-deep implantation group (implant depth ≤10 mm by instant angiogram after implantation,29 cases) and deep implantation group (implant depth> 10 mm by instant angiogram after implantation,11 cases).Pre-procedural aortic root characteristics (e.g. calcification, angle and dimensions) were assessed by CT. The impact of aortic root morphology on the implantation depth and clinical outcomes were also evaluated. Results: The age was (75.1±5.9) years with equal representation from the raphe-type and non-raphe type (52.5%(21/40) and 47.5%(19/40)).The bigger aorta angle ((56.5±4.5)° vs. (47.4±9.4)°, P=0.004),more frequent mild-calcification (HU850, <200 mm(3)) or severe-calcification(HU850, >1 000 mm(3)) of aortic leaflets (7/11 vs. 4/29, P=0.006), as well as higher ratio of left ventricular outflow tract perimeter to annulus perimeter ((109.2±7.5)% vs. (101.5±6.5)%, P=0.004) were found in the deep implantation group compared to the non-deep implantation group. The new in-hospital onset of bundle-branchheart-block or atrioventricular block conduction disturbance rate was higher in the deep implantation group than in the non-deep implantation group (6/11 vs. 2/29, P=0.030).Left ventricular ejection fraction was similar between deep implantation group and non-deep implantation group at baseline((49.9±8.9)% vs. (55.8±10.4)%, P=0.117), and was significantly lower in the deep implantation group than in the non-deep implantation group at 30 days after implantation ((51.6±12.8)% vs. (60.9±8.1)%, P=0.020). Conclusion: Aortic root morphology of bicuspid aortic valve patients is associated with implantation depth of the prosthesis during TAVR, which affects the conduction system and left ventricular function during and post TAVR.
Collapse
Affiliation(s)
- M Y Wang
- Coronary Intervention Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Pei HJ, Teng SY, Luo T, Wu YJ, Yang YJ, Qiao SB, Xu B, Gao RL. [Safety and feasibility of sheathless transfemoral aortic valve implantation]. Zhonghua Xin Xue Guan Bing Za Zhi 2017; 45:782-785. [PMID: 29036977 DOI: 10.3760/cma.j.issn.0253-3758.2017.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Objective: To investigate the safety and feasibility of sheathless transfemoral aortic valve replacement (TAVR). Methods: In this prospective study, we enrolled 23 patients with severe aortic stenosis (AS) who were inoperable or at high-risk for surgical aortic valve replacement operation in Fuwai hospital From September 2012 to June 2015. Multislice spiral CT and angiography of femoral artery showed that all patients had minimal femoral artery diameters (<6.5 mm) and severe calcification which was not suitable for transfemoral TAVR through sheath. We attempted to apply the sheathless transfemoral TAVR using Venus-A prosthesis without sheath insertion, and procedure related complication during the procedure and hospital stay were observed. Results: The 6 mm×30 mm balloon was used for femoral artery predilation in 1 patient with iliofemoral artery stenosis before delivery system was transported. In the other 22 patients, the delivery system was transported directly. A total of 21 patients finished TAVR with transfemoral sheathless technique. In 2 patients, prosthesis was unable to fully expand after release due to severe valve calcification, and patients received urgent surgical aortic valve replacement. One patient had valve dislocation into the ascending aorta that was not related to the sheathless replacement technique, and delivery system and Venus-A valve were removed after femoral artery was opened surgically, and repeated sheathless TAVR implantation was performed and was successful. Moderate aortic regurgitation occurred in 2 patients immediately after procedure, and trace or mild aortic regurgitation was detected in rest of the patients. One patient had puncture site rupture and bleeding after procedure, and was successfully treated by balloon compression without blood transfusion. Complete atrioventricular block occurred in 3 patients within 24 hours after procedure and lasted after 48-72 hours, permanent pacemakers were implanted in these patients. Conclusion: The sheathless transfemoral technique in TAVR is safe and feasible in severe aortic stenosis patients with small access vessel diameter.
Collapse
Affiliation(s)
- H J Pei
- Coronary Heart Disease Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | | | | | | | | | | | | | | |
Collapse
|
6
|
He Z, Teng SY, Song GY, Gao HY, Hao J, Ding C, Pei HJ, Zhang EL, Chen LY, Wu YJ. Acute effects of catheter-based renal sympathetic denervation on hemodynamics after acute myocardial infarction in pigs. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht308.p2219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
7
|
Abstract
The immediate signal-transduction response of osteoblasts to acute trauma is poorly characterized. We have developed a simple in vitro model for osteoblast trauma to investigate aspects of the molecular mechanisms of wound healing in bone. Herein we report the specific, rapid, and transient phosphorylation of extracellular signal-regulated kinase (ERK) 1 and 2 in osteoblasts as a response to disruption ("wounding") of a confluent monolayer. The mitogen-activated protein kinase (MAPK) cascades of p38 and stress-activated protein kinase/c-jun N-terminal kinase (SAPK/JNK) were not activated by this perturbation. The response to wounding was equivalent to the activation of ERK by the addition of exogenous growth factors, and the perturbation-dependent phosphorylation of ERK can be suppressed by an inhibitor of heparin-binding growth factors. Conditioned media from wounded monolayers can induce the phosphorylation of ERK in unperturbed monolayers. Using immunohistochemistry, it was demonstrated that the cells with increased levels of phosphorylated ERK were not localized to the wound edges. These results indicate that ERK activation is the result of an autocrine/paracrine response by osteoblasts to trauma. We speculate that osteoblasts respond to trauma with the release of soluble factors as part of an autocrine/paracrine modulation of the wound-healing process in bone.
Collapse
Affiliation(s)
- R W Katz
- Division of Oral Biology, School of Dental and Oral Surgery, Columbia University, New York, NY 10032, USA.
| | | | | | | |
Collapse
|
8
|
Teng SY. [Determination of contents of glycosaminoglycans in temporomandibular joint discs in dogs]. Zhonghua Kou Qiang Yi Xue Za Zhi 1992; 27:342-4, 384-5. [PMID: 1307954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Glycosaminoglycans (GAGs) are one of the important components of articular cartilage. The present study had determined the contents of uronic acid, galactomine, glucosamine, and hexosamine of temporomandibular joint discs in 10 dogs by Bitter's carbozole reaction method and derivative spectrophotometry. The data indicated that the contents of these components in different bands of the disc are not significantly different and that the discs of dogs contained averagely 0.6%, 0.987%, 0.4% and 1.4% of uronic acid, galactomine, glucosamine, and hexosamine respectively. The data also suggested that the discs contained keratan sulfate and chondroitin sulfate in some degree. This study is significant for analysing TMJ disc functions and its biomechanical properties in the future.
Collapse
Affiliation(s)
- S Y Teng
- College of Stomatology, West China University of Medical Sciences, Chengdu
| |
Collapse
|