1
|
Welarathna S, Velautham S, Sarasanandarajah S. Towards the establishment of national diagnostic reference levels for abdomen, KUB, and lumbar spine x-ray examinations in Sri Lanka: a multi-centric study. J Radiol Prot 2024; 44:021506. [PMID: 38537259 DOI: 10.1088/1361-6498/ad3837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 03/26/2024] [Indexed: 04/06/2024]
Abstract
Diagnostic reference levels (DRLs) and achievable doses (ADs) provide guidance to optimise radiation doses for patients undergoing medical imaging procedures. This multi-centre study aimed to compare institutional DRLs (IDRLs) across hospitals, propose ADs and multi-centric DRLs (MCDRLs) for four common x-ray examinations in Sri Lanka, and assess the potential for dose reduction. A prospective cross-sectional study of 894 adult patients referred for abdomen anteroposterior (AP), kidney-ureter-bladder (KUB) AP, lumbar spine AP, and lumbar spine lateral (LAT) x-ray examinations was conducted. Patient demographic information (age, sex, weight, BMI) and exposure parameters (tube voltage, tube current-exposure time product) were collected. Patient dose indicators were measured in terms of kerma-area product (PKA) using a PKAmeter. IDRLs, ADs, and MCDRLs were calculated following the International Commission on Radiological Protection guidelines, with ADs and MCDRLs defined as the 50th and 75th percentiles of the median PKAdistributions, respectively. IDRL ranges varied considerably across hospitals: 1.42-2.42 Gy cm2for abdomen AP, 1.51-2.86 Gy cm2for KUB AP, 0.83-1.65 Gy cm2for lumbar spine AP, and 1.76-4.10 Gy cm2for lumbar spine LAT. The proposed ADs were 1.82 Gy cm2(abdomen AP), 2.03 Gy cm2(KUB AP), 1.27 Gy cm2(lumbar spine AP), and 2.21 Gy cm2(lumbar spine LAT). MCDRLs were 2.24 Gy cm2(abdomen AP), 2.40 Gy cm2(KUB AP), 1.43 Gy cm2(lumbar spine AP), and 2.38 Gy cm2(lumbar spine LAT). Substantial intra- and inter-hospital variations in PKAwere observed for all four examinations. Although ADs and MCDRLs in Sri Lanka were comparable to those in the existing literature, the identified intra- and inter-hospital variations underscore the need for dose reduction without compromising diagnostic information. Hospitals with high IDRLs are recommended to review and optimise their practices. These MCDRLs serve as preliminary national DRLs, guiding dose optimisation efforts by medical professionals and policymakers.
Collapse
Affiliation(s)
- Sachith Welarathna
- Department of Physics, University of Peradeniya, Peradeniya 20400, Sri Lanka
- Postgraduate Institute of Science, University of Peradeniya, Peradeniya 20400, Sri Lanka
| | - Sivakumar Velautham
- Department of Physics, University of Peradeniya, Peradeniya 20400, Sri Lanka
| | | |
Collapse
|
2
|
Wickramasinghe SU, Ramanathan V, Sarasanandarajah S, De Zoyza M, Paranamana R. Occupational dose measurement in interventional cardiology practice. Radiat Prot Dosimetry 2024:ncae072. [PMID: 38555495 DOI: 10.1093/rpd/ncae072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 02/27/2024] [Accepted: 03/07/2024] [Indexed: 04/02/2024]
Abstract
Ensuring the safety of healthcare workers in interventional cardiology necessitates effective monitoring of occupational radiation exposure. This study aims to assess the accuracy of the over-apron single dosimetric approach compared with double dosimetric methods and explore the relationship between under-apron and over-apron doses. This investigation showed that the prescribed annual dose constraint of 20 mSv year-1 was not exceeded by the maximum annual occupational doses determined by dosimetric algorithms, which were 0.13 ± 0.02, 0.15 ± 0.02 and 0.27 ± 0.04 mSv, respectively. The study demonstrated excellent statistically significant correlations among single and double dosimetric algorithms and between direct under-apron and over-apron doses. Consequently, single dosimetric algorithms could effectively estimate doses for double dosimetric algorithms, highlighting the limited added value of under-apron measurements. These findings significantly impact the practice of interventional cardiology in Sri Lanka, playing a crucial role in enhancing radiation protection measures.
Collapse
Affiliation(s)
| | - Vijitha Ramanathan
- Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka
| | - Sivananthan Sarasanandarajah
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
- School of Health and Biomedical Sciences, RMIT University, Melbourne, VIC, Australia
| | | | | |
Collapse
|
3
|
Wickramasinghe SU, Ramanathan V, Sarasanandarajah S. Assessment of dosimetric approaches in evaluating radiation exposure for interventional cardiologists in Sri Lanka. Radiol Phys Technol 2024; 17:258-268. [PMID: 38240885 DOI: 10.1007/s12194-023-00774-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 12/06/2023] [Accepted: 12/27/2023] [Indexed: 03/01/2024]
Abstract
Interventional cardiologists face significant radiation exposure during interventional cardiology procedures. Therefore, this study focuses on assessing radiation exposure among interventional cardiologists during their procedures. Specifically, it aims to determine the effectiveness of both single and double dosimeter methods in estimating annual occupational radiation doses. This research holds pioneering significance as it represents the very first study undertaken in Sri Lanka. Thirteen interventional cardiologists performed 486 interventional cardiology procedures over three months in three different healthcare institutes. Active Hp(10) dosimeters were placed to measure radiation exposure. Effective doses were calculated using single and double dosimetric algorithms. Annual occupational doses were assessed on an operator basis. Statistical analyses were conducted to assess algorithmic differences and dose variations using the Kruskal-Wallis test and linear regression. The highest annual occupational dose for each dosimetric algorithm received as 2.00 ± 0.24 mSv, 2.29 ± 0.48 mSv, 3.35 ± 0.71 mSv, and 2.64 ± 0.42 mSv, respectively, and remained below the recommended safety limit of 20 mSv/year. The Kruskal-Wallis test revealed no significant differences in the effective doses among double dosimetric algorithms, as well as between single and double dosimetric algorithms (p > 0.05). Linear regression showed strong correlations among various algorithms, demonstrating consistency. The findings of this study hold significant effects on interventional cardiology practice in Sri Lanka, enhancing radiation safety and monitoring.
Collapse
Affiliation(s)
- Sachini Udara Wickramasinghe
- Department of Radiography and Radiotherapy, Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka.
| | - Vijitha Ramanathan
- Department of Radiography and Radiotherapy, Faculty of Allied Health Sciences, General Sir John Kotelawala Defence University, Ratmalana, Sri Lanka
| | - Sivananthan Sarasanandarajah
- Department of Physical Sciences, Peter MacCallum Cancer Institute, Melbourne, Australia
- School of Health and Biomedical Sciences, RMIT University, Melbourne, Australia
| |
Collapse
|
4
|
Welarathna S, Velautham S, Sarasanandarajah S. Towards the establishment of national diagnostic reference levels for chest x-ray examinations in Sri Lanka: a multi-centric study. J Radiol Prot 2023; 43. [PMID: 37738966 DOI: 10.1088/1361-6498/acfc51] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 09/22/2023] [Indexed: 09/24/2023]
Abstract
The establishment of diagnostic reference levels (DRLs) is an effective tool for optimising radiation doses delivered to patients during medical imaging procedures. This study aimed to compare the institutional DRLs (IDRLs) and propose a multi-centric diagnostic reference level (MCDRL) for chest x-ray examinations in adult patients in Sri Lanka. A prospective cross-sectional study was conducted with 1091 adult patients across six major tertiary care hospitals. Data on patient characteristics, such as age, sex, weight, and body mass index, and exposure parameters, such as tube voltage (kVp) and the product of tube current and exposure time (mAs), were collected. Patient doses were measured in terms of kerma-area product (PKA) using a PKAmeter mounted on the collimator of the x-ray tube. IDRLs were computed for each hospital according to the International Commission on Radiological Protection guidelines, and the 75th percentile PKAwas used to propose the MCDRL. The relationship between patient weight and exposure parameters was examined using Spearman's rank correlation to investigate the radiographic practice among hospitals. Results showed that IDRLs varied from 0.10 to 0.26 Gy cm2. The proposed MCDRL was 0.23 Gy cm2, substantially higher than the recently published DRLs from other countries. The median kVp ranged from 95 to 104, while mAs ranged from 2.5 to 5.6. Large variations in the PKAand exposure parameters were observed within and among hospitals. The elevated PKAvalues observed in this study were mostly due to the use of high mAs in clinical practice. The weak correlation observed between patient weight and exposure parameters suggests the need to standardise examination protocols concerning patient size. The observed dose variations demonstrate the need for the establishment of national DRLs. Until then, the proposed MCDRL can be considered as the benchmark dose level for chest x-ray examinations in Sri Lanka.
Collapse
Affiliation(s)
- Sachith Welarathna
- Department of Physics, University of Peradeniya, Peradeniya 20400, Sri Lanka
- Postgraduate Institute of Science, University of Peradeniya, Peradeniya 20400, Sri Lanka
| | - Sivakumar Velautham
- Department of Physics, University of Peradeniya, Peradeniya 20400, Sri Lanka
| | | |
Collapse
|
5
|
Welarathna S, Velautham S, Wanninayake M, Sarasanandarajah S. Evaluation of patient doses for routine digital radiography procedures toward establishing an institutional diagnostic reference levels: A case study in Sri Lanka. J Appl Clin Med Phys 2022; 23:e13852. [PMID: 36448529 PMCID: PMC9797157 DOI: 10.1002/acm2.13852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 10/30/2022] [Accepted: 11/02/2022] [Indexed: 12/02/2022] Open
Abstract
The present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X-ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma-area product (KAP) of adult patients undergoing routine projection X-ray examinations. The median and the 75th percentile KAP values obtained were compared with that of the single institution KAP values reported from India and Greece. This descriptive cross-sectional study was conducted in a public hospital in Uva province, Sri Lanka, with 400 adult patients aged 18-87 years and weighing 58 ± 20 kg. The patient-specific information (age, sex, weight, and height) and corresponding exposure parameters (tube voltage and current-exposure time product) were obtained. The KAP values were measured, and descriptive statistics were utilized for data analysis. The median KAP values obtained were proposed as IDRLs. The IDRLs in Gy.cm2 were 0.23 for cervical spine anterior-posterior (AP), 0.19 for cervical spine lateral (LAT), 0.10 for chest posterior-anterior (PA), 0.06 for knee joint AP, 0.05 for knee joint LAT, 1.47 for KUB AP, 0.85 for lumbar spine AP, 1.97 for lumbar spine LAT, 0.29 for shoulder joint AP, 0.61 for skull PA, and 0.60 for skull LAT examinations. The maximum to minimum ratio of KAP values ranged from 2.4 for KUB AP to 6.3 for the cervical spine AP examinations. The median and the 75th percentile of most of the examinations were comparable to corresponding KAP values reported by the countries mentioned above, except for the skull PA and LAT examinations. Accordingly, interquartile ranges of exposure parameters are recommended for skull examinations to improve the optimization of patient doses.
Collapse
Affiliation(s)
- Sachith Welarathna
- Postgraduate Institute of ScienceUniversity of PeradeniyaPeradeniyaSri Lanka,Horizon CampusMalabeSri Lanka
| | | | - Mihira Wanninayake
- School of Health ScienceBritish College of Applied StudiesColomboSri Lanka
| | | |
Collapse
|
6
|
Wong JHD, Ng KH, Sarasanandarajah S. Survey of postgraduate medical physics programmes in the Asia-Oceania region. Phys Med 2019; 66:21-28. [PMID: 31546154 DOI: 10.1016/j.ejmp.2019.09.079] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 09/10/2019] [Accepted: 09/11/2019] [Indexed: 11/28/2022] Open
Abstract
The increased use of medical imaging and radiation therapies has resulted in a high demand for medical physicists. Although medical physics programmes are well established in advanced countries, the same cannot be said for many low- and medium-income countries. In some countries, there may be huge variations in the graduates' skill and quality, which pose a problem in ensuring patient safety, providing quality assurance in treatments, optimisation of protocols and standardisation of quality. It also makes any yet-to-be-established regional peer recognition efforts problematic. In order to understand the depth of this problem, a survey was carried out as part of the home-based assignment under the RAS 6088 IAEA programme. A large diversity in terms of course content, duration, clinical training and student profile could be observed across the Asia-Oceania universities surveyed. Out of 25 programmes, only six received recognition from professional bodies, and they were mostly in Australia and New Zealand. Hence, to ensure quality education, a regional curriculum model needs to be developed to harmonise standards. And there is still a long way to go towards standardizing medical physics education and clinical training in the region.
Collapse
Affiliation(s)
- Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
| | - Kwan Hoong Ng
- Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
| | - Sivananthan Sarasanandarajah
- Department of Physical Sciences, Peter Mac Callum Cancer Centre, Melbourne, Australia & School of Health and Biomedical Sciences, RMIT University, Melbourne, Australia and Ex- IAEA, Vienna, Austria.
| |
Collapse
|
7
|
Bawazeer O, Herath S, Sarasanandarajah S, Kron T, Dunn L, Deb P. A simple and efficient method to measure beam attenuation through a radiotherapy treatment couch and immobilization devices. Australas Phys Eng Sci Med 2019; 42:1183-1189. [PMID: 31452056 DOI: 10.1007/s13246-019-00789-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 08/09/2019] [Indexed: 11/29/2022]
Abstract
We propose a simple and efficient method to measure beam attenuation in one or two dimensions using an amorphous silicon electronic portal imaging device (a-Si EPID). The proposed method was validated against ionization chamber measurements. Beam attenuation through treatment couches (Varian Medical Systems) and immobilization devices (CIVCO Radiotherapy, USA) was examined. The dependency of beam attenuation on field size, photon energy, thickness of the couch, and the presence of a phantom were studied. Attenuation images were derived by computing the percentage difference between images obtained without and with a couch or immobilization devices determining the percentage of attenuation at the center and the mean attenuation. The beam attenuation measurements obtained with an a-Si EPID and an ionization chamber agreed to within ± 0.10 to 1.80%. No difference was noted between the center and mean of an attenuated image for a small field size of 5 × 5 cm2, whereas a large field size of 15 × 15 cm2 exhibited differences of up to 1.13%. For an 18 MV beam, the a-Si EPID required additional build-up material for accurate assessment of beam attenuation. The a-Si EPID could measure differences in beam attenuation through an image guided radiotherapy (IGRT) couch regardless of the variabilities in couch thickness. Interestingly, the addition of a phantom reduced the magnitude of attenuation by approximately 1.20% for a field size of 15 × 15 cm2. A simple method is proposed that provides the user with beam attenuation data in either 2D or 1D within a few minutes.
Collapse
Affiliation(s)
- Omemh Bawazeer
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia. .,Discipline of Sciences, Umm Al-Qura University, Mecca, Saudi Arabia.
| | - Sisira Herath
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Sivananthan Sarasanandarajah
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia.,Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.,Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Australia
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Australia.,Sir Peter MacCallum Cancer Institute, University of Melbourne, Melbourne, Australia
| | - Leon Dunn
- Epworth Radiation Oncology, Epworth Hospital, Melbourne, Australia
| | - Pradip Deb
- Discipline of Medical Radiations, RMIT University, Melbourne, Australia
| |
Collapse
|
8
|
Bawazeer O, Sarasanandarajah S, Herath S, Kron T, Deb P. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID. Med Phys 2016. [DOI: 10.1118/1.4956403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
9
|
zehtabian M, Faghihi R, Mosleh-Shirazi M, Shepherd J, Mohammadi M, Sarasanandarajah S, Higgs B. SU-E-J-120: A Phantom-Based Comparison of Lung Tumor Planning Target Volumes and Organs a Risk Dose Reduction Between 4D-CT and 3D-CT. Med Phys 2013. [DOI: 10.1118/1.4814332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
10
|
Kunnil J, Sarasanandarajah S, Chacko E, Reinisch L. Effect of washing on identification of Bacillus spores by principal-component analysis of fluorescence data. Appl Opt 2006; 45:3659-64. [PMID: 16708113 DOI: 10.1364/ao.45.003659] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
The fluorescence spectra of Bacillus spores are measured at excitation wavelengths of 280, 310, 340, 370, and 400 nm. When cluster analysis is used with the principal-component analysis, the Bacillus globigii spores can be distinguished from the other species of Bacillus spores (B. cereus, B. popilliae, and B. thuringiensis). To test how robust the identification process is with the fluorescence spectra, the B. globigii is obtained from three separate preparations in different laboratories. Furthermore the fluorescence is measured before and after washing and redrying the B. globigii spores. Using the cluster analysis of the first two or three principal components of the fluorescence spectra, one is able to distinguish B. globigii spores from the other species, independent of preparing or washing the spores.
Collapse
Affiliation(s)
- Joseph Kunnil
- Department of Physics and Astronomy, University of Canterbury, Christchurch, New Zealand
| | | | | | | |
Collapse
|
11
|
Kunnil J, Sarasanandarajah S, Chacko E, Reinisch L. Fluorescence quantum efficiency of dry Bacillus globigii spores. Opt Express 2005; 13:8969-8979. [PMID: 19498931 DOI: 10.1364/opex.13.008969] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Fluorescence spectroscopy has been used to measure fluorescence quantum efficiency (QE) of dried Bacillus spores (washed and unwashed) fixed to a quartz substrate. Fluorescence spectra and QE of anthracene in ethanol was used as the standard. We measured the absorption and fluorescence signal of the spores as a function of the number of spores. The absorption was measured from 600 nm to 250 nm using the reflectance in an integrating sphere. The fluorescence spectra were measured using excitation wavelengths at 280, 360 and 400 nm at room temperature. The absorption cross sections for the unwashed spores were 1.3 x 10-8, 8 x 10-9, and 5 x 10-9 mm2/spore at 280, 360 and 400 nm, respectively. The fluorescence QE was 0.13 +/- 0.03, 0.33 +/- 0.12 and 0.43 +/- 0.26 at 280, 360, and 400 nm, respectively. The QE decreased by a factor of 2, 4 and 4 at these same wavelengths after washing and redrying the spores.
Collapse
|
12
|
Sarasanandarajah S, Kunnil J, Bronk BV, Reinisch L. Two-dimensional multiwavelength fluorescence spectra of dipicolinic acid and calcium dipicolinate. Appl Opt 2005; 44:1182-1187. [PMID: 15765697 DOI: 10.1364/ao.44.001182] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Dipicolinic acid (DPA) and the Ca2+ complex of DPA (CaDPA) are major chemical components of bacterial spores. With fluorescence being considered for the detection and identification of spores, it is important to understand the optical properties of the major components of the spores. We report in some detail on the room-temperature fluorescence excitation and emission spectra of DPA and its calcium ion complex and provide a comparison of the excitation-emission spectrum in a dry, wet paste and aqueous form. DPA solutions have weak, if any, fluorescence, with increased fluorescence when the DPA is dry. After exposure to a broad source UV light of the DPA, wet or dry, we observe a large increase in fluorescence with a maximum intensity emission peak at around 440 nm for excitation light with a wavelength of around 360 nm. There is a slight blueshift in the absorption spectra of UV-exposed DPA from the unexposed DPA solution. CaDPA in solution shows a slight fluorescence with increased fluorescence in the dry form, and a substantial increase of fluorescence was observed after UV exposure with an emission peak of around 410 nm for excitation around 305 nm. The detailed excitation-emission spectra are necessary for better interpretation of the fluorescence spectra of bacterial spores where DPA is a major chemical component.
Collapse
|