1
|
Staal FH, Siang KNW, Brouwer CL, Janssen J, Budiharto TC, Haverkort DM, Hollmann B, Jacobs I, De Jong MA, van de Sande MA, Vanneste BG, De Jong IJ, Verzijlbergen JF, Langendijk JA, Smeenk RJ, Aluwini S. Pretrial Quality Assurance for Hypofractionated Salvage Radiation Therapy After Prostatectomy in the Multi-Institutional PERYTON-trial. Adv Radiat Oncol 2024; 9:101379. [PMID: 38405312 PMCID: PMC10885595 DOI: 10.1016/j.adro.2023.101379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 09/12/2023] [Indexed: 02/27/2024] Open
Abstract
Purpose The PERYTON trial is a multicenter randomized controlled trial that will investigate whether the treatment outcome of salvage external beam radiation therapy (sEBRT) will be improved with hypofractionated radiation therapy. A pretrial quality assurance (QA) program was undertaken to ensure protocol compliance within the PERYTON trial and to assess variation in sEBRT treatment protocols between the participating centers. Methods and Materials Completion of the QA program was mandatory for each participating center (N = 8) to start patient inclusion. The pretrial QA program included (1) a questionnaire on the center-specific sEBRT protocol, (2) a delineation exercise of the clinical target volume (CTV) and organs at risk, and (3) a treatment planning exercise. All contours were analyzed using the pairwise dice similarity coefficient (DSC) and the 50th and 95th percentile Hausdorff distance (HD50 and HD95, respectively). The submitted treatment plans were reviewed for protocol compliance. Results The results of the questionnaire showed that high-quality, state-of-the-art radiation therapy techniques were used in the participating centers and identified variations of the sEBRT protocols used concerning the position verification and preparation techniques. The submitted CTVs showed significant variation, with a range in volume of 29 cm3 to 167 cm3, a mean pairwise DSC of 0.52, and a mean HD50 and HD95 of 2.3 mm and 24.4 mm, respectively. Only in 1 center the treatment plan required adaptation before meeting all constraints of the PERYTON protocol. Conclusions The pretrial QA of the PERYTON trial demonstrated that high-quality, but variable, radiation techniques were used in the 8 participating centers. The treatment planning exercise confirmed that the dose constraints of the PERYTON protocol were feasible for all participating centers. The observed variation in CTV delineation led to agreement on a new (image-based) delineation guideline to be used by all participating centers within the PERYTON trial.
Collapse
Affiliation(s)
- Floor H.E. Staal
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| | - Kelvin Ng Wei Siang
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| | - Charlotte L. Brouwer
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| | - Jorinde Janssen
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| | - Tom C.G. Budiharto
- Department of Radiation Oncology, Catharina Hospital, Eindhoven, The Netherlands
| | | | - Birgit Hollmann
- Department of Radiation Oncology, HAGA Ziekenhuis, Den Haag, The Netherlands
| | - Inge Jacobs
- Zuidwest Radiotherapy Institute Vlissingen/Roosendaal, Vlissingen, The Netherlands
| | | | | | - Ben G.L. Vanneste
- Department of Radiation Oncology, MAASTRO Clinic, GROW—School for Oncology and Developmental Biology, Maastricht, The Netherlands
| | - Igle Jan De Jong
- Department of Urology, University Medical Centre Groningen, Groningen, The Netherlands
| | - J. Fred Verzijlbergen
- Department of Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Johannes A. Langendijk
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| | - Robert Jan Smeenk
- Department of Radiation Oncology, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Shafak Aluwini
- Department of Radiation Oncology, University Medical Centre Groningen, Groningen, The Netherlands
| |
Collapse
|