Sime FB, Wallis S, Jamieson C, Hills T, Gilchrist M, Santillo M, Seaton RA, Drummond F, Roberts J. Evaluation of the stability of temocillin in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy in accordance with the requirements of the UK NHS Yellow Cover Document. Eur J Hosp Pharm 2023; 30:e76-e81. [PMID: 35609967 PMCID: PMC10086727 DOI: 10.1136/ejhpharm-2022-003286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 05/03/2022] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVE To evaluate the stability of temocillin solution in two elastomeric infusion devices - Easypump II LT 270-27- S and Dosi-Fusor L25915-250D1 for OPAT administration during 14 days of 5°C±3°C fridge storage followed by 24 hour exposure at an in-use temperature of 32°C, when reconstituted with 0.3% citrate buffer at pH7. METHODS Stability testing was conducted in accordance with standard protocols in the UK National Health Service Yellow Cover Document (YCD). A stability indicating assay method was applied using a high-performance liquid chromatography (HPLC) system with a photodiode array detector. Low (500 mg/240 mL), intermediate (4000 mg/240 mL) and high (6000 mg/240 mL) temocillin concentrations were tested in triplicate devices with duplicate samples taken at 11 time points during fridge storage and subsequent in-use temperature exposure. RESULT The percentage of temocillin remaining after 14 days of fridge storage was greater than 97% in both devices and at all concentrations tested. During subsequent in-use temperature exposure, a 95% stability limit was achieved for 12 hours except for the high concentration (25 mg/mL) in the Dosi-Fusor device. It met this criterion for only 10 hours - the percent of temocillin remaining at 12 hours was 94.5%. However, for all devices and the doses tested, the degradation of temocillin was <9% at the end of 24 hours in-use temperature exposure. CONCLUSION Temocillin reconstituted with 0.3% citrate buffer at pH7 in elastomeric infusion devices can be stored in a fridge (2°C-8°C) for 14 days meeting the YCD acceptance criteria. Considering <5% degradation, the current data supports twice daily dosing of temocillin within the OPAT setting. In jurisdictions where a <10% degradation limit is acceptable, once daily dosing with 24-hour continuous infusion may be considered. Temocillin is a useful alternative to other broad-spectrum anti-Gram-negative agents currently utilised in the OPAT setting and supports the wider antimicrobial stewardship agenda.
Collapse
Affiliation(s)
- Fekade Bruck Sime
- University of Queensland Centre for Clinical Research, Faculty of Medicine,the University of Queensland, Herston, Queensland, Australia
| | - Steven Wallis
- University of Queensland Centre for Clinical Research, Faculty of Medicine,the University of Queensland, Herston, Queensland, Australia
| | - Conor Jamieson
- Pharmacy Department, Sandwell and West Birmingham Hospitals NHS Trust, Birmingham, West Midlands, UK
| | - Tim Hills
- Pharmacy Department and OPAT Service, Nottingham University Hospitals, Nottingham, UK, Bristol, UK
| | - Mark Gilchrist
- Department of Pharmacy/Infection, Imperial College Healthcare NHS Trust, London, UK
| | - Mark Santillo
- Quality Assurance, University Hospitals Plymouth NHS Trust, Plymouth, UK and University Hospitals Bristol and Weston NHS Trust, Bristol, UK, Bristol, UK
| | | | | | - Jason Roberts
- University of Queensland Centre for Clinical Research, Faculty of Medicine,the University of Queensland, Herston, Queensland, Australia
- Herston Infectious Diseases Institute (HeIDI), Metro North Health, Brisbane, Queensland, Australia
- Departments of Pharmacy and Intensive Care Medicine, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
- Division of Anaesthesiology Critical Care Emergency and Pain Medicine, Nîmes University Hospital, University of Montpellier, Nîmes, France
| |
Collapse
|