1
|
Brombal L, Arfelli F, Brun F, Di Trapani V, Endrizzi M, Menk RH, Perion P, Rigon L, Saccomano M, Tromba G, Olivo A. Edge-illumination spectral phase-contrast tomography. Phys Med Biol 2024; 69:075027. [PMID: 38471186 PMCID: PMC10991267 DOI: 10.1088/1361-6560/ad3328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/23/2024] [Accepted: 03/12/2024] [Indexed: 03/14/2024]
Abstract
Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62μm) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations. An example of a micro CT application (20μm voxel size) on an iodine-perfusedex vivomurine model is reported. The work demonstrates that spectral-phase contrast combines the advantages of spectral imaging, i.e. high-Zmaterial discrimination capability, and phase-contrast imaging, i.e. soft tissue sensitivity, yielding simultaneously mass density maps of water, calcium, and iodine with an accuracy of 1.1%, 3.5%, and 1.9% (root mean square errors), respectively. Results also show a 9-fold increase in the signal-to-noise ratio of the water channel when compared to standard spectral decomposition. The application to the murine model revealed the potential of the technique in the simultaneous 3D visualization of soft tissue, bone, and vasculature. While being implemented by using a broad spectrum (pink beam) at a synchrotron radiation facility (Elettra, Trieste, Italy), the proposed experimental setup can be readily translated to compact laboratory systems including conventional x-ray tubes.
Collapse
Affiliation(s)
- Luca Brombal
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Fulvia Arfelli
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Francesco Brun
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- Department of Engineering and Architecture, University of Trieste, Via A. Valerio 10, I-34127 Trieste, Italy
| | - Vittorio Di Trapani
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Marco Endrizzi
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, GWC1E 6BT, London, United Kingdom
| | - Ralf H Menk
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- Elettra-Sincrotrone Trieste S.C.p.A, I-34149 Basovizza Trieste, Italy
- Department of Computer and Electrical Engineering, Midsweden University, Holmgatan 10, Sundsvall, Sweden
| | - Paola Perion
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Luigi Rigon
- Department of Physics, University of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
- INFN Division of Trieste, Via A. Valerio 2, I-34127 Trieste, Italy
| | - Mara Saccomano
- Helmholtz Zentrum München, Helmholtz Pioneer Campus, Ingolstädter Landstraße 1, D-85764 Neuherberg, Germany
| | - Giuliana Tromba
- Elettra-Sincrotrone Trieste S.C.p.A, I-34149 Basovizza Trieste, Italy
| | - Alessandro Olivo
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, GWC1E 6BT, London, United Kingdom
| |
Collapse
|