1
|
Zhong X, Nickel MD, Kannengiesser SAR, Dale BM, Han F, Gao C, Shih SF, Dai Q, Curiel O, Tsao TC, Wu HH, Deshpande V. Accelerated free-breathing liver fat and R 2 * quantification using multi-echo stack-of-radial MRI with motion-resolved multidimensional regularized reconstruction: Initial retrospective evaluation. Magn Reson Med 2024. [PMID: 38650444 DOI: 10.1002/mrm.30117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 02/25/2024] [Accepted: 04/01/2024] [Indexed: 04/25/2024]
Abstract
PURPOSE To improve image quality, mitigate quantification biases and variations for free-breathing liver proton density fat fraction (PDFF) andR 2 * $$ {\mathrm{R}}_2^{\ast } $$ quantification accelerated by radial k-space undersampling. METHODS A free-breathing multi-echo stack-of-radial MRI method was developed with compressed sensing with multidimensional regularization. It was validated in motion phantoms with reference acquisitions without motion and in 11 subjects (6 patients with nonalcoholic fatty liver disease) with reference breath-hold Cartesian acquisitions. Images, PDFF, andR 2 * $$ {\mathrm{R}}_2^{\ast } $$ maps were reconstructed using different radial view k-space sampling factors and reconstruction settings. Results were compared with reference-standard results using Bland-Altman analysis. Using linear mixed-effects model fitting (p < 0.05 considered significant), mean and SD were evaluated for biases and variations of PDFF andR 2 * $$ {\mathrm{R}}_2^{\ast } $$ , respectively, and coefficient of variation on the first echo image was evaluated as a surrogate for image quality. RESULTS Using the empirically determined optimal sampling factor of 0.25 in the accelerated in vivo protocols, mean differences and limits of agreement for the proposed method were [-0.5; -33.6, 32.7] s-1 forR 2 * $$ {\mathrm{R}}_2^{\ast } $$ and [-1.0%; -5.8%, 3.8%] for PDFF, close to those of a previous self-gating method using fully sampled radial views: [-0.1; -27.1, 27.0] s-1 forR 2 * $$ {\mathrm{R}}_2^{\ast } $$ and [-0.4%; -4.5%, 3.7%] for PDFF. The proposed method had significantly lower coefficient of variation than other methods (p < 0.001). Effective acquisition time of 64 s or 59 s was achieved, compared with 171 s or 153 s for two baseline protocols with different radial views corresponding to sampling factor of 1.0. CONCLUSION This proposed method may allow accelerated free-breathing liver PDFF andR 2 * $$ {\mathrm{R}}_2^{\ast } $$ mapping with reduced biases and variations.
Collapse
Affiliation(s)
- Xiaodong Zhong
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Physics and Biology in Medicine Interdepartmental Program, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Bioengineering, Samueli School of Engineering, University of California Los Angeles, Los Angeles, California, USA
| | - Marcel D Nickel
- MR Application Predevelopment, Siemens Healthineers AG, Erlangen, Germany
| | | | - Brian M Dale
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Cary, North Carolina, USA
| | - Fei Han
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Los Angeles, California, USA
| | - Chang Gao
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Los Angeles, California, USA
| | - Shu-Fu Shih
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Bioengineering, Samueli School of Engineering, University of California Los Angeles, Los Angeles, California, USA
| | - Qing Dai
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Bioengineering, Samueli School of Engineering, University of California Los Angeles, Los Angeles, California, USA
| | - Omar Curiel
- Department of Mechanical and Aerospace Engineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Tsu-Chin Tsao
- Department of Mechanical and Aerospace Engineering, University of California Los Angeles, Los Angeles, CA, USA
| | - Holden H Wu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Physics and Biology in Medicine Interdepartmental Program, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Bioengineering, Samueli School of Engineering, University of California Los Angeles, Los Angeles, California, USA
| | - Vibhas Deshpande
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Austin, Texas, USA
| |
Collapse
|