1
|
Muñoz J, Oliver-De La Cruz J, Forte G, Pumera M. Graphene-based 3D-Printed nanocomposite bioelectronics for monitoring breast cancer cell adhesion. Biosens Bioelectron 2023; 226:115113. [PMID: 36764127 DOI: 10.1016/j.bios.2023.115113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 01/11/2023] [Accepted: 01/28/2023] [Indexed: 02/05/2023]
Abstract
This work examines the suitability of graphene-based 3D-printed nanocomposite bioelectronics as innovative systems to in situ monitor and evaluate both breast cancer cell adhesion and the chemosensitivity of anti-cancer drugs. With this aim, 3D-printed nanocomposite graphene electrodes (3D-nGEs) -made of a commercially available graphene/polylactic acid filament- have been covalently biofunctionalized with an extracellular matrix protein (i.e., fibronectin) by exploiting the carbon reactivity of 3D-nGEs. The specificity and selectivity of the developed electrochemical system to monitor breast cancer cell adhesion has been tested via electrochemical impedance spectroscopy (EIS). Importantly, the resulting 3D-printed bioelectronic system displayed excellent accuracy for the rapid screening of anti-cancer drugs, which exactly corresponded with the results achieved by the standard optical method, while having the advantage of employing a label-free approach. In light of the current state-of-the-art in the field, this proof-of-concept connects electronics to biological systems within 3D printing technology, providing the bases for the sustainable and cost-effective manufacturing of graphene-based 3D-printed nanocomposite bioelectronics to simulate in vivo microenvironments using in situ and real time electronic output signals.
Collapse
|
2
|
Muñoz J, Pumera M. 3D-Printed COVID-19 immunosensors with electronic readout. Chem Eng J 2021; 425:131433. [PMID: 34393616 PMCID: PMC8349461 DOI: 10.1016/j.cej.2021.131433] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 06/30/2021] [Accepted: 07/18/2021] [Indexed: 05/09/2023]
Abstract
3D printing technology has brought light in the fight against the COVID-19 global pandemic event through the decentralized and on-demand manufacture of different personal protective equipment and medical devices. Nonetheless, since this technology is still in an early stage, the use of 3D-printed electronic devices for antigen test developments is almost an unexplored field. Herein, a robust and general bottom-up biofunctionalization approach via surface engineering is reported aiming at providing the bases for the fabrication of the first 3D-printed COVID-19 immunosensor prototype with electronic readout. The 3D-printed COVID-19 immunosensor was constructed by covalently anchoring the COVID-19 recombinant protein on a 3D-printed graphene-based nanocomposite electrode surface. The electrical readout relies on impedimetrically monitoring changes at the electrode/electrolyte interface after interacting with the monoclonal COVID-19 antibody via competitive assay, fact that hinders the redox conversion of a benchmark redox marker. Overall, the developed 3D-printed system exhibits promising electroanalytical capabilities in both buffered and human serum samples, displaying an excellent linear response with a detection limit at trace levels (0.5 ± 0.1 μg·mL-1). Such achievements demonstrate advantage of light-of-speed distribution of 3D printing datafiles with localized point-of-care low-cost printing and bioelectronic devices to help contain the spread of emerging infectious diseases such as COVID-19. This technology is applicable to any post-COVID-19 SARS diseases.
Collapse
Affiliation(s)
- Jose Muñoz
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Brno 61600, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Brno 61600, Czech Republic
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, Taiwan
- 3D Printing & Innovation Hub, Department of Food Technology, Mendel University in Brno, Zemedelska 1, Brno CZ-613 00, Czech Republic
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| |
Collapse
|
3
|
Ataide VN, Rocha DP, de Siervo A, Paixão TRLC, Muñoz RAA, Angnes L. Additively manufactured carbon/black-integrated polylactic acid 3Dprintedsensor for simultaneous quantification of uric acid and zinc in sweat. Mikrochim Acta 2021; 188:388. [PMID: 34668076 DOI: 10.1007/s00604-021-05007-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 08/26/2021] [Indexed: 11/29/2022]
Abstract
For the first time the development of an electrochemical method for simultaneous quantification of Zn2+ and uric acid (UA) in sweat is described using an electrochemically treated 3D-printed working electrode. Sweat analysis can provide important information about metabolites that are valuable indicators of biological processes. Improved performance of the 3D-printed electrode was achieved after electrochemical treatment of its surface in an alkaline medium. This treatment promotes the PLA removal (insulating layer) and exposes carbon black (CB) conductive sites. The pH and the square-wave anodic stripping voltammetry technique were carefully adjusted to optimize the method. The peaks for Zn2+ and UA were well-defined at around - 1.1 V and + 0.45 V (vs. CB/PLA pseudo-reference), respectively, using the treated surface under optimized conditions. The calibration curve showed a linear range of 1 to 70 µg L-1 and 1 to 70 µmol L-1 for Zn2+ and UA, respectively. Relative standard deviation values were estimated as 4.8% (n = 10, 30 µg L-1) and 6.1% (n = 10, 30 µmol L-1) for Zn2+ and UA, respectively. The detection limits for Zn2+ and UA were 0.10 µg L-1 and 0.28 µmol L-1, respectively. Both species were determined simultaneously in real sweat samples, and the achieved recovery percentages were between 95 and 106% for Zn2+ and 82 and 108% for UA.
Collapse
Affiliation(s)
- Vanessa N Ataide
- Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP, 05508-000, Brazil
| | - Diego P Rocha
- Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP, 05508-000, Brazil.
| | - Abner de Siervo
- Institute of Physics "Gleb Wataghin", Applied Physics Department, State University of Campinas, Campinas, SP, 13083-859, Brazil
| | - Thiago R L C Paixão
- Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP, 05508-000, Brazil
| | - Rodrigo A A Muñoz
- Institute of Chemistry, Federal University of Uberlândia, Uberlândia, MG, 38400-902, Brazil
| | - Lucio Angnes
- Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, São Paulo, SP, 05508-000, Brazil
| |
Collapse
|
4
|
Muñoz J, Redondo E, Pumera M. Versatile Design of Functional Organic-Inorganic 3D-Printed (Opto)Electronic Interfaces with Custom Catalytic Activity. Small 2021; 17:e2103189. [PMID: 34510744 DOI: 10.1002/smll.202103189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 07/12/2021] [Indexed: 06/13/2023]
Abstract
The ability to combine organic and inorganic components in a single material represents a great step toward the development of advanced (opto)electronic systems. Nowadays, 3D-printing technology has generated a revolution in the rapid prototyping and low-cost fabrication of 3D-printed electronic devices. However, a main drawback when using 3D-printed transducers is the lack of robust functionalization methods for tuning their capabilities. Herein, a simple, general and robust in situ functionalization approach is reported to tailor the capabilities of 3D-printed nanocomposite carbon/polymer electrode (3D-nCE) surfaces with a battery of functional inorganic nanoparticles (FINPs), which are appealing active units for electronic, optical and catalytic applications. The versatility of the resulting functional organic-inorganic 3D-printed electronic interfaces is provided in different pivotal areas of electrochemistry, including i) electrocatalysis, ii) bio-electroanalysis, iii) energy (storage and conversion), and iv) photoelectrochemical applications. Overall, the synergism of combining the transducing characteristics of 3D-nCEs with the implanted tuning surface capabilities of FINPs leads to new/enhanced electrochemical performances when compared to their bare 3D-nCE counterparts. Accordingly, this work elucidates that FINPs have much to offer in the field of 3D-printing technology and provides the bases toward the green fabrication of functional organic-inorganic 3D-printed (opto)electronic interfaces with custom catalytic activity.
Collapse
Affiliation(s)
- Jose Muñoz
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Purkyňova 123, Brno, 61200, Czech Republic
| | - Edurne Redondo
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Purkyňova 123, Brno, 61200, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Purkyňova 123, Brno, 61200, Czech Republic
- 3D Printing & Innovation Hub, Department of Food Technology, Mendel University in Brno, Zemedelska 1/1665, Brno, 613 00, Czech Republic
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-Gu, Seoul, 03722, South Korea
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, 40402, Taiwan
| |
Collapse
|
5
|
Muñoz J, Redondo E, Pumera M. Bistable (Supra)molecular Switches on 3D-Printed Responsive Interfaces with Electrical Readout. ACS Appl Mater Interfaces 2021; 13:12649-12655. [PMID: 33305562 DOI: 10.1021/acsami.0c14487] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Molecular switching memories have gained great importance in recent years because of the current sharp increase in the production of consumer electronics. Herein, 3D-printed nanocomposite carbon electrodes (3D-nCEs) have been explored as unconventional responsive interfaces to electrically readout bistable molecular switches via electrochemical impedance spectroscopy as the output system. As a proof-of-concept, two different 3D-printed responsive interfaces have been devised using surface engineering for covalently anchoring (supra)molecular components that well-define two electrical states (on/off) driven by either electrical or optical stimuli. Accordingly, this work paves the way for the functionalization of 3D-nCEs through fundamental chemistry, opening up new horizons in unprecedented tailored 3D-printed responsive interfaces which could be utilized as potential (bio)sensors, (opto)electronic devices, or molecular logic gates.
Collapse
Affiliation(s)
- Jose Muñoz
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Brno 61600, Czech Republic
| | - Edurne Redondo
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Brno 61600, Czech Republic
| | - Martin Pumera
- Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology (CEITEC-BUT), Brno 61600, Czech Republic
- Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, Taiwan
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, Brno CZ-613 00, Czech Republic
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Korea
| |
Collapse
|
6
|
López Marzo AM, Mayorga-Martinez CC, Pumera M. 3D-printed graphene direct electron transfer enzyme biosensors. Biosens Bioelectron 2019; 151:111980. [PMID: 31999587 DOI: 10.1016/j.bios.2019.111980] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 12/17/2019] [Accepted: 12/19/2019] [Indexed: 01/26/2023]
Abstract
Three-dimensional (3D) printing technology offers attractive possibilities for many fields. In electrochemistry, 3D printing technology has been used to fabricate customized 3D-printed electrodes as a platform to develop bio/sensing, energy generation and storage devices. Here, we use a 3D-printed graphene/polylactic (PLA) electrode made by additive manufacturing technology and immobilize horseradish peroxidase (HRP) to create a direct electron transfer enzyme-based biosensors for hydrogen peroxide detection. Gold nanoparticles are included in the system to confirm and facilitate heterogeneous electron transfer. This work opens a new direction for the fabrication of third-generation electrochemical biosensors using 3D printing technology, with implications for applications in the environmental and biomedical fields.
Collapse
Affiliation(s)
- Adaris M López Marzo
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Carmen C Mayorga-Martinez
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic
| | - Martin Pumera
- Center for Advanced Functional Nanorobots, Department of Inorganic Chemistry, University of Chemistry and Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic; Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea; Department of Medical Research, China Medical University Hospital, China Medical University, No. 91 Hsueh-Shih Road, Taichung, Taiwan; Future Energy and Innovation Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, Brno, CZ-616 00, Czech Republic.
| |
Collapse
|