AlMokhatieb AA. Adjunctive use of Er, Cr: YSGG laser, Potassium titanyl Phosphate laser, and photosensitizer on extrusion bond strength of radicular dentin to bioceramic sealers.
Photodiagnosis Photodyn Ther 2022;
41:103205. [PMID:
36417971 DOI:
10.1016/j.pdpdt.2022.103205]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 11/13/2022] [Accepted: 11/18/2022] [Indexed: 11/21/2022]
Abstract
AIM
To assess the impact of adjunctive final root canal disinfection regime curcumin photosensitizer (CP) activated by Photodynamic therapy (PDT), Er, Cr: YSGG laser (ECL), and Potassium titanyl Phosphate (KTP) laser on the bond integrity of two endodontic Bioceramic (BC) sealers.
MATERIALS AND METHOD
Decoration of eighty human single-rooted teeth was performed up to a cementoenamel junction. After instrumentation, all samples were irrigated with 2.25% NaOCl solution followed by 17% EDTA. The specimens were divided arbitrarily into 8 groups (n = 10) based on the adjunctive final irrigation method used. Group 1 and 5 (Control): No adjunctive regime, cleaned using 2.25% NaOCl + 17% EDTA, group 2 and group 6: CP activated by PDT, Group 3 and Group 7 using ECL, Group 4 and Group 8: KTP laser. Following disinfection samples in groups 1, 2, 3, and 4 were obturated using Sankin apatite root canal sealer (SARS). Specimens in groups 5, 6, 7, and 8 were obturated using Pro-root endo sealer (PRES). Sectioning of samples was performed. The sectioned specimens were subjected to a compressive loading exerted via a steel plunger moving at a 0.5 mm/min crosshead speed till debonding. Means and standard deviations (SD) of EBS of BC sealer with the root canal dentin were assessed using one-way analysis of variance (ANOVA) and Post Hoc Tukey multiple comparison tests. The level of significance was measured at p = 0.05.
RESULTS
The coronal section of samples in group 5 (Na-E-PRES) exhibited the highest bond value. The lowest PBS was displayed by the middle third of specimens in group 6. Group 1 (Na-E-SARS), group 3 (Na-E-ECL-SARS), group 5 (Na-E-PRES), and group 7 (Na-E-ECL-PRES) exhibited comparable bond values (p>0.05). Whereas, group 2 (Na-E-PDT-SARS) and group 4 (Na-E-PTPL-SARS), group 6 (Na-E-PDT-PRES), and group 8 (Na-E-PTPL-PRES) were found to be comparable (p>0.05).
CONCLUSION
Adjunctive use of Er, Cr: YSGG laser displayed better extrusion bond strength with BC root canal sealer compared to CP activated by PDT and KTP laser. Bond strength is influenced by the type of irrigation.
Collapse