1
|
Takizawa T, Ikegami S, Uehara M, Kuraishi S, Oba H, Munakata R, Hatakenaka T, Kamanaka T, Miyaoka Y, Mimura T, Koseki M, Takahashi J. Surgical results for cervical spondylotic myelopathy with inconsistent between deep tendon reflex findings and magnetic resonance imaging findings. J Clin Neurosci 2023; 107:157-161. [PMID: 36376150 DOI: 10.1016/j.jocn.2022.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Revised: 10/23/2022] [Accepted: 11/05/2022] [Indexed: 11/13/2022]
Abstract
BACKGROUND To evaluate the surgical results of patients with cervical spondylotic myelopathy (CSM) with inconsistency between deep tendon reflex findings and cervical magnetic resonance imaging (MRI) findings and to analyze the differences between patients with good and poor surgical outcomes. METHODS We evaluated 50 subjects with CSM (30 males, 20 females; mean age: 70.4 years) who underwent posterior surgery and were followed for at least 1 year postoperatively. Matched CSM was defined as a consistent preoperative neurological pattern determined by deep tendon reflex and cervical MRI T2-weighted high-signal intramedullary area or stenosis in the most cranial compression levels. A lack of consistency was classified as unmatched CSM. Recovery rate (RR) according to Japanese Orthopaedic Association (JOA) scoring preoperatively and at 1 year postoperatively were compared between the groups. RESULTS The matched and unmatched CSM group included 27 subjects (13 males, 14 females; mean age: 68.2 years) and 23 subjects (17 males, 6 females; mean age: 72.8 years), respectively. RR was significantly higher in the matched CSM group (56.1 ± 3.7 % vs 36.8 ± 2.7 %; p = 0.002). Unmatched CSM was significantly associated with a lower RR independently of sex, patient age, surgical procedure, preoperative JOA score, diagnosis levels, and complication of diabetes. CONCLUSIONS Postoperative JOA score RR was significantly diminished among unmatched CSM patients comprising of 46% of cases. Some patients with unmatched CSM had multiple levels of spinal canal stenosis, foraminal stenosis, and peripheral neuropathy, suggesting that surgical results were poorer than those of matched CSM.
Collapse
Affiliation(s)
- Takashi Takizawa
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Shota Ikegami
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Masashi Uehara
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan.
| | - Shugo Kuraishi
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Hiroki Oba
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Ryo Munakata
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Terue Hatakenaka
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Takayuki Kamanaka
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Yoshinari Miyaoka
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Tetsuhiko Mimura
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| | - Michihiko Koseki
- Faculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| | - Jun Takahashi
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, Asahi 3-1-1, Matsumoto, Nagano 390-8621, Japan
| |
Collapse
|
2
|
Elasy AN, Nafea OE. Critical Hypermagnesemia in Preeclamptic Women Under a Magnesium Sulfate Regimen: Incidence and Associated Risk Factors. Biol Trace Elem Res 2022:10.1007/s12011-022-03479-x. [PMID: 36413336 DOI: 10.1007/s12011-022-03479-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 11/06/2022] [Indexed: 11/23/2022]
Abstract
Magnesium sulfate is used as prophylaxis and treatment of severe preeclampsia/eclampsia, albeit its safety and toxicity are a concern. We designed this study to estimate the incidence of critical hypermagnesemia in severely preeclamptic women under a magnesium sulfate regimen at 8 h following its administration and to identify the associated risk factors as the primary outcomes. Also, secondary outcomes were to compare baseline characteristics, laboratory findings, and maternal-neonatal complications stratified by the baseline serum magnesium (Mg2+) in those women, and to assess the degree of agreement between patellar reflex and serum Mg2+ concentration 8 h following magnesium sulfate administration. We conducted a retrospective study including severely preeclamptic women receiving magnesium sulfate from June 2016 to May 2021. We enrolled 429 women in the study. Two-hundred sixty-one (60.8%) of the included women developed critical hypermagnesemia. Preeclamptic women with high baseline serum Mg2+ concentration demonstrated significantly affected renal functions, hepatic transaminase activities, and low platelet count as well as more reported maternal complications compared to those with low baseline serum Mg2. Multivariable logistic regression revealed that a lower gestational age, a higher uric acid concentration, and a higher baseline serum Mg2+ concentration were independently associated with an increased risk of critical hypermagnesemia. The agreement between deep tendon reflex assessment and serum Mg2+ concentration was slight although not significant. The maternal-neonatal outcomes were non-significant in women with critical hypermagnesemia. More vigilant monitoring through assessment of both serum Mg2+ concentration and deep tendon reflex should be considered especially in high-risk women.
Collapse
Affiliation(s)
- Amina Nagy Elasy
- Department of Obstetrics and Gynecology, Faculty of Medicine, Zagazig University, Zagazig, 44519, Egypt
- Specialist Obstetrics and Gynecology, New Mowast Hospital, Salmiya, Kuwait
| | - Ola Elsayed Nafea
- Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Zagazig University, Zagazig, 44519, Egypt.
- Department of Clinical Pharmacy, College of Pharmacy, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia.
| |
Collapse
|
3
|
Kim YW. Clinical availability of the deep tendon reflex test using a novel apparatus in healthy subjects. J Phys Ther Sci 2015; 27:317-20. [PMID: 25729159 PMCID: PMC4339129 DOI: 10.1589/jpts.27.317] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 08/11/2014] [Indexed: 11/24/2022] Open
Abstract
[Purpose] The aim of this study was to investigate the clinical usefulness of a novel apparatus intended to improve the consistency and reliability of the deep tendon reflex (DTR) test. [Subjects] The participants included 50 healthy adults (25 male and 25 female) between 20 and 31 years of age who showed no knee abnormalities upon physical examination. [Methods] The intraclass correlation coefficient (ICC) was used to verify inter-rater reliability for two parameters examined in the DTR test using a newly designed apparatus. These parameters were the patellar reflex amplitude and first knee extension angle. Pearson's product correlation coefficient was then used to examine the correlation between these two parameters. [Results] The inter-rater reliability analysis showed a high correlation between the examiners for both DTR parameters (ICCs = 0.91-0.96). In addition, a significant positive correlation was observed between the two parameters (r = 0.91). [Conclusion] The results show that it is possible to use the novel apparatus described herein to obtain reliable results in the DTR test.
Collapse
Affiliation(s)
- Yong-Wook Kim
- Department of Physical Therapy, College of Medical Sciences, Jeonju University: 303 Cheonjam-ro, Wansan-gu, Jeonju, Jeonbuk-do 560-759, Republic of Korea
| |
Collapse
|