Grande G, Manno M, Alberghina N, Barbera C, Zulli C, Tontini GE, Pigò F, Conigliaro R. Quick, safe and effective repair of EUS-related duodenal perforation using over-the-scope clip system (with video).
Dig Liver Dis 2016;
48:1099-100. [PMID:
27211883 DOI:
10.1016/j.dld.2016.04.013]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2016] [Accepted: 04/19/2016] [Indexed: 02/06/2023]
Abstract
Duodenal perforation is a rare but potentially life-threating complication of bilio-pancreatic endoscopic-ultrasound (EUS) examination. Here we report a case of 90 yeas-old patient underwent to EUS with curvilinear ecoendoscope and complicated by duodenal wall perforation. As reported in our case, Over-the-scope clipping system represents a quick, safe and effective approach in order close the leak and prevent further complication.
Collapse