1
|
Lin Z, Shi C, Huang X, Tang C, Yuan Y. A Study on Damage of T800 Carbon Fiber/Epoxy Composites under In-Plane Shear Using Acoustic Emission and Digital Image Correlation. Polymers (Basel) 2023; 15:4319. [PMID: 37959999 PMCID: PMC10650694 DOI: 10.3390/polym15214319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 10/23/2023] [Accepted: 10/27/2023] [Indexed: 11/15/2023] Open
Abstract
In addition to measuring the strain, stress, and Young's modulus of materials through tension and compression, in-plane shear modulus measurement is also an important part of parameter testing of composites. Tensile testing of ±45° composite laminates is an economical and effective method for measuring in-plane shear strength. In this paper, the in-plane shear modulus of T800 carbon fiber/epoxy composites were measured through tensile tests of ±45° composite laminates, and acoustic emission (AE) was used to characterize the damage of laminates under in-plane shear loading. Factor analysis (FA) on acoustic emission parameters was performed and the reconstructed factor scores were clustered to obtain three damage patterns. Finally, the development and evolution of the three damage patterns were characterized based on the cumulative hits of acoustic emission. The maximum bearing capacity of the laminated plate is about 17.54 kN, and the average in-plane shear modulus is 5.42 GPa. The damage modes of laminates under in-plane shear behavior were divided into three types: matrix cracking, delamination and fiber/matrix interface debonding, and fiber fracture. The characteristic parameter analysis of AE showed that the damage energy under in-plane shear is relatively low, mostly below 2000 mV × ms, and the frequency is dispersed between 150-350 kHz.
Collapse
Affiliation(s)
- Zikai Lin
- Shenzhong Link Management Center, Zhongshan 528400, China
| | - Changheng Shi
- Faculty of Civil Engineering and Mechanics, Jiangsu University, Zhenjiang 212013, China;
| | - Xiaochu Huang
- Shenzhong Link Management Center, Zhongshan 528400, China
| | - Can Tang
- College of Civil Science and Engineering, Yangzhou University, Yangzhou 225127, China
| | - Ye Yuan
- School of Electrical and Information Engineering, Jiangsu University, Zhenjiang 212013, China
| |
Collapse
|
2
|
Yang Y, Chen H, Wu H. A generalized fuzzy clustering framework for incomplete data by integrating feature weighted and kernel learning. PeerJ Comput Sci 2023; 9:e1600. [PMID: 37869452 PMCID: PMC10588703 DOI: 10.7717/peerj-cs.1600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 08/28/2023] [Indexed: 10/24/2023]
Abstract
Missing data presents a challenge to clustering algorithms, as traditional methods tend to pad incomplete data first before clustering. To combine the two processes of padding and clustering and improve the clustering accuracy, a generalized fuzzy clustering framework is proposed based on optimal completion strategy (OCS) and nearest prototype strategy (NPS) with four improved algorithms developed. Feature weights are introduced to reduce outliers' influence on the cluster centers, and kernel functions are used to solve the linear indistinguishability problem. The proposed algorithms are evaluated regarding correct clustering rate, iteration number, and external evaluation indexes with nine datasets from the UCI (University of California, Irvine) Machine Learning Repository. The results of the experiment indicate that the clustering accuracy of the feature weighted kernel fuzzy C-means algorithm with NPS (NPS-WKFCM) and feature weighted kernel fuzzy C-means algorithm with OCS (OCS-WKFCM) under varying missing rates is superior to that of seven conventional algorithms. Experiments demonstrate that the enhanced algorithm proposed for clustering incomplete data is superior.
Collapse
Affiliation(s)
- Ying Yang
- College of Information and Intelligence, Hunan Agricultural University, Changsha, China
| | - Haoyu Chen
- New Energy College, Xi’an Shiyou University, Xi’an, China
| | - Haoshen Wu
- College of Management, Guangdong University of Technology, Guangzhou, China
| |
Collapse
|
3
|
Montaser E, Díez JL, Bondia J. Glucose Prediction under Variable-Length Time-Stamped Daily Events: A Seasonal Stochastic Local Modeling Framework. Sensors (Basel) 2021; 21:3188. [PMID: 34064325 PMCID: PMC8124701 DOI: 10.3390/s21093188] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 04/23/2021] [Accepted: 04/28/2021] [Indexed: 11/16/2022]
Abstract
Accurate glucose prediction along a long-enough time horizon is a key component for technology to improve type 1 diabetes treatment. Subjects with diabetes might benefit from supervision and control systems that accurately predict risks and trigger corrective actions early enough with improved mitigation. However, large intra-patient variability poses big challenges to glucose prediction. In previous works by the authors, clustering and local modeling techniques with seasonal stochastic models proved to be efficient, allowing for good glucose prediction accuracy for long prediction horizons. Continuous glucose monitoring (CGM) data were partitioned into fixed-length postprandial time subseries and clustered with Fuzzy C-Means to collect similar behaviors, enforcing seasonality at each cluster after subseries concatenation. Then, seasonal stochastic models were identified for each cluster and local predictions were integrated into a global prediction. However, free-living conditions do not support the fixed-length partition of CGM data since daily events duration is variable. In this work, a new algorithm is provided to overcome this constraint, allowing better coping with patient's variability under variable-length time-stamped daily events in supervision and control applications. Besides predicted glucose, two real-time indices are additionally provided-a crispness index, indicating good representation of current glucose behavior by a single model, and a normality index, allowing for the detection of an abnormal glucose behavior (unusual according to registered historical data). The framework is tested in a proof-of-concept in silico study with ten patients over four month training data and two independent two month validation datasets, with and without abnormal behaviors, from the distribution version of the UVA/Padova simulator extended with diverse sources of intra-patient variability.
Collapse
Affiliation(s)
- Eslam Montaser
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, s/n, 46022 València, Spain; (E.M.); (J.-L.D.)
| | - José-Luis Díez
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, s/n, 46022 València, Spain; (E.M.); (J.-L.D.)
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Jorge Bondia
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, s/n, 46022 València, Spain; (E.M.); (J.-L.D.)
- Centro de Investigación Biomédica en Red de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, 28029 Madrid, Spain
| |
Collapse
|
4
|
Abstract
Purpose: Accurate segmentation of retinal blood vessel is an important task in computer-aided diagnosis and surgery planning of diabetic retinopathy. Despite the high-resolution of photographs in fundus photography, the contrast between the blood vessels and the retinal background tends to be poor. Materials and Methods: In this proposed method, contrast-limited adaptive histogram equalization is used for noise cancellation and improving the local contrast of the image. By uniform distribution of gray values, it enhances the image and makes the hidden features more visible. The extraction of the retinal blood vessel depends on two levels of optimization. The first level is the extraction of blood vessels from the retinal image using Kirsch's templates. The second level is used to find the coarse vessels with the assistance of the unsupervised method of Fuzzy C-Means clustering. After segmentation, to remove the optic disc, the region-based active contour method is used. The proposed system is evaluated using DRIVE dataset with 40 images. Results: The performance of the proposed approach is comparable with state of the art techniques. The proposed technique outperforms the existing techniques by achieving an accuracy of 99.55%, sensitivity of 71.83%, and specificity of 99.86% in the experimental setup. Conclusion: The results show that this approach is a suitable alternative technique for the supervised method and it is support for similar fundus images dataset.
Collapse
Affiliation(s)
- T Jemima Jebaseeli
- Department of Computer Science and Engineering, Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, India
| | - C Anand Deva Durai
- Department of Computer Science and Engineering, King Khalid University, Abha, Saudi Arabia
| | - J Dinesh Peter
- Department of Computer Science and Engineering, Karunya Institute of Technology and Sciences, Coimbatore, Tamil Nadu, India
| |
Collapse
|
5
|
Dinov M, Leech R. Modeling Uncertainties in EEG Microstates: Analysis of Real and Imagined Motor Movements Using Probabilistic Clustering-Driven Training of Probabilistic Neural Networks. Front Hum Neurosci 2017; 11:534. [PMID: 29163110 PMCID: PMC5671986 DOI: 10.3389/fnhum.2017.00534] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 10/20/2017] [Indexed: 11/13/2022] Open
Abstract
Part of the process of EEG microstate estimation involves clustering EEG channel data at the global field power (GFP) maxima, very commonly using a modified K-means approach. Clustering has also been done deterministically, despite there being uncertainties in multiple stages of the microstate analysis, including the GFP peak definition, the clustering itself and in the post-clustering assignment of microstates back onto the EEG timecourse of interest. We perform a fully probabilistic microstate clustering and labeling, to account for these sources of uncertainty using the closest probabilistic analog to KM called Fuzzy C-means (FCM). We train softmax multi-layer perceptrons (MLPs) using the KM and FCM-inferred cluster assignments as target labels, to then allow for probabilistic labeling of the full EEG data instead of the usual correlation-based deterministic microstate label assignment typically used. We assess the merits of the probabilistic analysis vs. the deterministic approaches in EEG data recorded while participants perform real or imagined motor movements from a publicly available data set of 109 subjects. Though FCM group template maps that are almost topographically identical to KM were found, there is considerable uncertainty in the subsequent assignment of microstate labels. In general, imagined motor movements are less predictable on a time point-by-time point basis, possibly reflecting the more exploratory nature of the brain state during imagined, compared to during real motor movements. We find that some relationships may be more evident using FCM than using KM and propose that future microstate analysis should preferably be performed probabilistically rather than deterministically, especially in situations such as with brain computer interfaces, where both training and applying models of microstates need to account for uncertainty. Probabilistic neural network-driven microstate assignment has a number of advantages that we have discussed, which are likely to be further developed and exploited in future studies. In conclusion, probabilistic clustering and a probabilistic neural network-driven approach to microstate analysis is likely to better model and reveal details and the variability hidden in current deterministic and binarized microstate assignment and analyses.
Collapse
Affiliation(s)
- Martin Dinov
- Computational, Cognitive and Clinical Neuroimaging Laboratory, Division of Brain Sciences, The Centre for Restorative Neuroscience, Imperial College London, London, United Kingdom
| | - Robert Leech
- Computational, Cognitive and Clinical Neuroimaging Laboratory, Division of Brain Sciences, The Centre for Restorative Neuroscience, Imperial College London, London, United Kingdom
| |
Collapse
|
6
|
Kaya IE, Pehlivanlı AÇ, Sekizkardeş EG, Ibrikci T. PCA based clustering for brain tumor segmentation of T1w MRI images. Comput Methods Programs Biomed 2017; 140:19-28. [PMID: 28254075 DOI: 10.1016/j.cmpb.2016.11.011] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2016] [Revised: 10/10/2016] [Accepted: 11/23/2016] [Indexed: 06/06/2023]
Abstract
BACKGROUND AND OBJECTIVE Medical images are huge collections of information that are difficult to store and process consuming extensive computing time. Therefore, the reduction techniques are commonly used as a data pre-processing step to make the image data less complex so that a high-dimensional data can be identified by an appropriate low-dimensional representation. PCA is one of the most popular multivariate methods for data reduction. This paper is focused on T1-weighted MRI images clustering for brain tumor segmentation with dimension reduction by different common Principle Component Analysis (PCA) algorithms. Our primary aim is to present a comparison between different variations of PCA algorithms on MRIs for two cluster methods. METHODS Five most common PCA algorithms; namely the conventional PCA, Probabilistic Principal Component Analysis (PPCA), Expectation Maximization Based Principal Component Analysis (EM-PCA), Generalize Hebbian Algorithm (GHA), and Adaptive Principal Component Extraction (APEX) were applied to reduce dimensionality in advance of two clustering algorithms, K-Means and Fuzzy C-Means. In the study, the T1-weighted MRI images of the human brain with brain tumor were used for clustering. In addition to the original size of 512 lines and 512 pixels per line, three more different sizes, 256 × 256, 128 × 128 and 64 × 64, were included in the study to examine their effect on the methods. RESULTS The obtained results were compared in terms of both the reconstruction errors and the Euclidean distance errors among the clustered images containing the same number of principle components. CONCLUSION According to the findings, the PPCA obtained the best results among all others. Furthermore, the EM-PCA and the PPCA assisted K-Means algorithm to accomplish the best clustering performance in the majority as well as achieving significant results with both clustering algorithms for all size of T1w MRI images.
Collapse
Affiliation(s)
- Irem Ersöz Kaya
- Mersin University, Software Eng. Dept. 33440 Tarsus, Mersin, Turkey.
| | | | | | - Turgay Ibrikci
- Cukurova University, Electrical-Electronics Eng. Dept. 01330, Adana, Turkey.
| |
Collapse
|
7
|
Wang H, Feyes D, Mulvihill J, Oleinick N, Maclennan G, Fei B. Multiscale Fuzzy C-Means Image Classification for Multiple Weighted MR Images for the Assessment of Photodynamic Therapy in Mice. Proc SPIE Int Soc Opt Eng 2007; 6512. [PMID: 24386526 DOI: 10.1117/12.710188] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
We are investigating in vivo small animal imaging and analysis methods for the assessment of photodynamic therapy (PDT), an emerging therapeutic modality for cancer treatment. Multiple weighted MR images were acquired from tumor-bearing mice pre- and post-PDT and 24-hour after PDT. We developed an automatic image classification method to differentiate live, necrotic and intermediate tissues within the treated tumor on the MR images. We used a multiscale diffusion filter to process the MR images before classification. A multiscale fuzzy C-means (FCM) classification method was applied along the scales. The object function of the standard FCM was modified to allow multiscale classification processing where the result from a coarse scale is used to supervise the classification in the next scale. The multiscale fuzzy C-means (MFCM) method takes noise levels and partial volume effects into the classification processing. The method was validated by simulated MR images with various noise levels. For simulated data, the classification method achieved 96.0 ± 1.1% overlap ratio. For real mouse MR images, the classification results of the treated tumors were validated by histologic images. The overlap ratios were 85.6 ± 5.1%, 82.4 ± 7.8% and 80.5 ± 10.2% for the live, necrotic, and intermediate tissues, respectively. The MR imaging and the MFCM classification methods may provide a useful tool for the assessment of the tumor response to photodynamic therapy in vivo.
Collapse
Affiliation(s)
- Hesheng Wang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106
| | - Denise Feyes
- Department of Radiation Oncology, Case Western Reserve University, Cleveland, OH, 44106
| | - John Mulvihill
- Department of Radiation Oncology, Case Western Reserve University, Cleveland, OH, 44106
| | - Nancy Oleinick
- Department of Radiation Oncology, Case Western Reserve University, Cleveland, OH, 44106
| | - Gregory Maclennan
- Department of Pathology, Case Western Reserve University, Cleveland, OH, 44106
| | - Baowei Fei
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106 ; Department of Radiology Case Western Reserve University, Cleveland, OH, 44106
| |
Collapse
|