Mozingo JD, Akbari-Shandiz M, Van Straaten MG, Murthy NS, Schueler BA, Holmes DR, McCollough CH, Zhao KD. Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study. J Electromyogr Kinesiol 2022; 62:102350. [PMID: 31481296 PMCID: PMC7036020 DOI: 10.1016/j.jelekin.2019.08.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 07/12/2019] [Accepted: 08/19/2019] [Indexed: 02/03/2023] Open
Abstract
Scapula and humerus motion associated with common manual wheelchair tasks is hypothesized to reduce the subacromial space. However, previous work relied on either marker-based motion capture for kinematic measures, which is prone to skin-motion artifact; or ultrasound imaging for arthrokinematic measures, which are 2D and acquired in statically-held positions. The aim of this study was to use a fluoroscopy-based approach to accurately quantify glenohumeral kinematics during manual wheelchair use, and compare tasks for a subset of parameters theorized to be associated with mechanical impingement. Biplane images of the dominant shoulder were acquired during scapular plane elevation, propulsion, sideways lean, and weight-relief raise in ten manual wheelchair users with spinal cord injury. A computed tomography scan of the shoulder was obtained, and model-based tracking was used to quantify six-degree-of-freedom glenohumeral kinematics. Axial rotation and superior/inferior and anterior/posterior humeral head positions were characterized for full activity cycles and compared between tasks. The change in the subacromial space was also determined for the period of each task defined by maximal change in the aforementioned parameters. Propulsion, sideways lean, and weight-relief raise, but not scapular plane elevation, were marked by mean internal rotation (8.1°, 10.8°, 14.7°, -49.2° respectively). On average, the humeral head was most superiorly positioned during the weight-relief raise (1.6 ± 0.9 mm), but not significantly different from the sideways lean (0.8 ± 1.1 mm) (p = 0.191), and much of the task was characterized by inferior translation. Scaption was the only task without a defined period of superior translation on average. Pairwise comparisons revealed no significant differences between tasks for anterior/posterior position (task means range: 0.1-1.7 mm), but each task exhibited defined periods of anterior translation. There was not a consistent trend across tasks between internal rotation, superior translation, and anterior translation with reductions in the subacromial space. Further research is warranted to determine the likelihood of mechanical impingement during these tasks based on the measured task kinematics and reductions in the subacromial space.
Collapse
Affiliation(s)
- Joseph D. Mozingo
- Biomedical Engineering and Physiology Graduate Program,
Mayo Clinic Graduate School of Biomedical Sciences, Mayo Clinic, Rochester, MN,
USA,Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| | | | | | | | | | - David R. Holmes
- Department of Physiology and Biomedical Engineering, Mayo
Clinic, Rochester, MN, USA
| | | | - Kristin D. Zhao
- Department of Physical Medicine and Rehabilitation, Mayo
Clinic, Rochester, MN, USA
| |
Collapse
|
2
|
Mozingo JD, Akbari Shandiz M, Marquez FM, Schueler BA, Holmes DR 3rd, McCollough CH, Zhao KD. Validation of imaging-based quantification of glenohumeral joint kinematics using an unmodified clinical biplane fluoroscopy system. J Biomech 2018; 71:306-12. [PMID: 29478696 DOI: 10.1016/j.jbiomech.2018.02.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2017] [Revised: 02/01/2018] [Accepted: 02/04/2018] [Indexed: 11/23/2022]
Abstract
Model-based tracking, using CT and biplane fluoroscopy, allows highly accurate quantification of glenohumeral motion and changes in the subacromial space. Previous investigators have used custom-built biplane fluoroscopes designed specifically for kinematic applications, which are available at few institutions and require FDA approval prior to clinical use. The aim of this study was to demonstrate the utility of an off-the-shelf clinical biplane fluoroscope for kinematic applications by validating model-based tracking for measurement of glenohumeral motion using an unmodified clinical system. Biplane images of each shoulder of a cadaver torso were acquired at various joint positions and during simulated movements along anatomical planes of motion. The pose of each humerus and scapula was determined using model-based tracking and compared to a bead-based gold standard. Error due to a temporal-offset between corresponding biplane images, characteristic of clinical biplane systems, was determined by comparison of measured and known relative position of 2 bead clusters of a phantom that was imaged while moved throughout the fluoroscopy image volume. Model-based tracking had global kinematic mean absolute errors of 0.27 mm and 0.29° (static), and 0.22-0.32 mm and 0.12-0.45° (dynamic). Glenohumeral mean absolute errors were 0.39 mm and 0.45° (static), and 0.36-0.42 mm and 0.41-0.48° (dynamic). The temporal-offset was predicted to add errors of 0.06-0.85 mm and 0.05-0.28° for cadaveric trials for the speeds examined. For defined speeds, sub-millimeter and sub-degree kinematic accuracy and precision were achieved using an unmodified clinical biplane fluoroscope for quantification of glenohumeral motion.
Collapse
|