1
|
Dong H, Jiang Z, Chen Y, Han H, Zhou Y, Wang X, Xu M, Liu L. Ratiometric electrochemical determination of hydroxyl radical based on graphite paper modified with metal-organic frameworks and impregnated with salicylic acid. Mikrochim Acta 2024; 191:121. [PMID: 38308135 DOI: 10.1007/s00604-024-06202-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 01/08/2024] [Indexed: 02/04/2024]
Abstract
Hydroxyl radical (•OH) detection is pivotal in medicine, biochemistry and environmental chemistry. Yet, electrochemical method-specific detection is challenging because of hydroxyl radicals' high reactivity and short half-life. In this study, we aimed to modify the electrode surface with a specific recognition probe for •OH. To achieve this, we conducted a one-step hydrothermal process to fabricate a CoZnMOF bimetallic organic framework directly onto conductive graphite paper (Gp). Subsequently, we introduced salicylic acid (SA) and methylene blue (MB), which easily penetrated the pores of CoZnMOF. By selectively capturing •OH by SA and leveraging the electrochemical signal generated by the reaction product, we successfully developed an electrochemical sensor Gp/CoZnMOF/SA + MB. The prepared sensor exhibited a good linear relationship with •OH concentrations ranging from 1.25 to 1200 nM, with a detection limit of 0.2 nM. Additionally, the sensor demonstrated excellent reproducibility and accuracy due to the incorporation of an internal reference. It exhibited remarkable selectivity for •OH detection, unaffected by other electrochemically active substances. The establishment of this sensor provides a way to construct MOF-modified sensors for the selective detection of other reactive oxygen species (ROS), offering a valuable experimental basis for ROS-related disease research and environmental safety investigations.
Collapse
Affiliation(s)
- Hui Dong
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China.
| | - Zhenlong Jiang
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, People's Republic of China
| | - Yanan Chen
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China
| | - Huabo Han
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China.
| | - Yanli Zhou
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, People's Republic of China
| | - Xiaobing Wang
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, People's Republic of China.
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China
| | - Lantao Liu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China.
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, People's Republic of China.
| |
Collapse
|
2
|
Garima, Jindal S, Garg S, Matai I, Packirisamy G, Sachdev A. Dual-emission copper nanoclusters-based ratiometric fluorescent probe for intracellular detection of hydroxyl and superoxide anion species. Mikrochim Acta 2021; 188:13. [PMID: 33389152 DOI: 10.1007/s00604-020-04683-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 12/03/2020] [Indexed: 01/12/2023]
Abstract
A fluorescent nanoprobe based on copper nanoclusters (CuNCs) has been developed for ratiometric detection of hydroxyl radicals (•OH) and superoxide anion radicals (O2•-). Two differently luminescent CuNCs, namely cyan-emissive poly(methacrylic acid)-protected copper nanoclusters (PCuNCs) and orange-emissive bovine serum albumin-protected CuNCs (BCuNCs), were conjugated to obtain a hybrid, dual-emission nanoprobe (PCuNCs-BCuNCs) with the corresponding peaks at 445 nm and 652 nm at an excitation wavelength of 360 nm. In particular, the fluorescence peak at 445 nm gradually enhanced with the incremental addition of •OH and O2•-. However, the fluorescence emission at 652 nm was greatly quenched in the presence of •OH, while in case of O2•-, the fluorescence intensity remained constant. The differential response of the PCuNCs-BCuNCs towards •OH and O2•- formed the basis of ratiometric detection. Under optimal conditions, the PCuNCs-BCuNCs exhibited good sensitivity and linearity towards •OH and O2•- with limits of detection of 0.15 μM and 1.8 μM, respectively. Moreover, the nanoprobe exhibited high selectivity for •OH and O2•- over other potential ROS interferences. Besides, PCuNCs-BCuNCs were eventually applied for qualitative and quantitative ratiometric assessment of intracellular •OH and O2•- in L-132 cells. Therefore, this strategy unveils a new potential for copper nanocluster-based sensing of ROS.
Collapse
|
3
|
Zhang L, Chen L. Visual detection of melamine by using a ratiometric fluorescent probe consisting of a red emitting CdTe core and a green emitting CdTe shell coated with a molecularly imprinted polymer. Mikrochim Acta 2018; 185:135. [PMID: 29594750 DOI: 10.1007/s00604-017-2664-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Accepted: 12/31/2017] [Indexed: 10/18/2022]
Abstract
A composite ratiometric fluorescent probe is described for visual detection of melamine (MEL) in milk samples. It is based on the use of red emitting and green emitting CdTe quantum dots, and a mesoporous molecularly imprinted polymer. The red emitting QDs are embedded in the silica microsphere to serve as a core, and the green emitting QDs are coated on the surface of the silica microsphere as a shell. A molecularly imprinted polymer (MIP) with specific recognition sites for MEL was placed on the shell. If MEL is bound by the MIP, the green fluorescence is quenched due to hydrogen bond interaction. The red emission, in contrast, remains unchanged. Quenching leads to a change in the color of fluorescence from red-green to purely red. This effect allows for visual and instrumental detection of MEL. The mesoporous structure of the MIP reduces the mass transfer resistance and enhances the accessibility of sites for MEL. Response is linear in the 50-1000 ng mL-1 MEL concentration range, and the limit of detection is 13 ng mL-1. The fluorescent probe was successfully applied to the analysis of MEL-spiked milk samples and gave recoveries between 94.1 and 98.7%, with 3.6-5.1% relative standard deviations. Graphical abstract Schematic of the preparation and detection of the composite probe. The probe was applied for the selective recognition and visual detection of melamine (MEL).
Collapse
|