Braun P, Delgado R, Drago M, Fanti D, Fleury H, Hofmann J, Izopet J, Kühn S, Lombardi A, Mancon A, Marcos MA, Mileto D, Sauné K, O'Shea S, Pérez-Rivilla A, Ramble J, Trimoulet P, Vila J, Whittaker D, Artus A, Rhodes D. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay. J Clin Virol 2017; 92:75-82. [PMID: 28599228 DOI: 10.1016/j.jcv.2017.05.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 05/03/2017] [Accepted: 05/06/2017] [Indexed: 11/30/2022]
Abstract
BACKGROUND Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System.¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. STUDY DESIGN Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. RESULTS Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log10cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log10cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. CONCLUSIONS The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay.
Collapse
Affiliation(s)
- Patrick Braun
- Laboratory Dr. Knechten, Medical Center for HIV and Hepatitis, Aachen, Germany
| | - Rafael Delgado
- Microbiology Department, Hospital Universitario 12 de Octubre and Insituto de Investigation, Hospital 12 de Octubre (i+12) Madrid, Spain
| | - Monica Drago
- Clinical Chemistry and Microbiology Laboratories, Niguarda Ca' Granda Hospital, Milan, Italy
| | - Diana Fanti
- Clinical Chemistry and Microbiology Laboratories, Niguarda Ca' Granda Hospital, Milan, Italy
| | - Hervé Fleury
- Virology Department, Hôpital Pellegrin, CHU, Bordeaux, France
| | - Jörg Hofmann
- Virology Department, Labor Berlin - Charité Vivantes GmbH, Berlin, Germany
| | - Jacques Izopet
- Department of Virology, Federative Institute of Biology, CHU, Toulouse, France
| | - Sebastian Kühn
- Virology Department, Labor Berlin - Charité Vivantes GmbH, Berlin, Germany
| | - Alessandra Lombardi
- Clinical Microbiology, Virology and Bioemergence Diagnosis, L. Sacco University Hospital, Milan, Italy
| | - Alessandro Mancon
- Clinical Microbiology, Virology and Bioemergence Diagnosis, L. Sacco University Hospital, Milan, Italy
| | - Mª Angeles Marcos
- Department of Clinical Microbiology, Hospital Clinic, School of Medicine, University of Barcelona, Centre for International Health Research (CRESIB), Barcelona, Spain
| | - Davide Mileto
- Virology Department, Labor Berlin - Charité Vivantes GmbH, Berlin, Germany
| | - Karine Sauné
- Department of Virology, Federative Institute of Biology, CHU, Toulouse, France
| | - Siobhan O'Shea
- Viapath Analytics, Infection Sciences, Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom
| | - Alfredo Pérez-Rivilla
- Microbiology Department, Hospital Universitario 12 de Octubre and Insituto de Investigation, Hospital 12 de Octubre (i+12) Madrid, Spain
| | - John Ramble
- Viapath Analytics, Infection Sciences, Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom
| | | | - Jordi Vila
- Department of Clinical Microbiology, Hospital Clinic, School of Medicine, University of Barcelona, Centre for International Health Research (CRESIB), Barcelona, Spain
| | - Duncan Whittaker
- Laboratory Medicine Building, North Lane, Northern General Hospital, Sheffield, United Kingdom
| | - Alain Artus
- Beckman Coulter, Immunotech, 130 Ave Lattre de Tassigny, Marseille 13009, France
| | - Daniel Rhodes
- Beckman Coulter, Immunotech, 130 Ave Lattre de Tassigny, Marseille 13009, France.
| |
Collapse
|