Gupta A, Samdani S, Sharma S, Grover M, Soni S, Hada MS, Kumar A. Round Window Visibility in Cochlear Implantation : Pre-operative Prediction Using Various Radiological Parameters.
Indian J Otolaryngol Head Neck Surg 2024;
76:781-787. [PMID:
38440579 PMCID:
PMC10908965 DOI:
10.1007/s12070-023-04280-5]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 10/08/2023] [Indexed: 03/06/2024] Open
Abstract
Purpose
The round window approach has become the most preferred route for electrode insertion in cochlear implant surgery; however, it is not possible at times due to difficult round window membrane (RWM) visibility. Our study aims to investigate the relationship between preoperative radiological parameters and the surgical visibility of the RWM in Cochlear implant patients.
Methodology
A prospective cross-sectional study of 31 patients, age < 6 years, with bilateral severe to profound sensorineural hearing loss was conducted at a tertiary care hospital. The preoperative HRCT temporal bone scan was studied, and the parameters evaluated were facial nerve location, facial recess width, and RWM visibility prediction. All patients were operated on via the posterior tympanotomy. The surgical RWM visibility was done after optimal drilling of the posterior tympanotomy recess. The relationship between the radiological parameters and surgical visibility of RWM was evaluated.
Results
The difference in the facial nerve location as per the type of RWM was found to be significant (p value < 0.05). However, the facial recess width was not significantly associated with RWM visibility. The radiological prediction of RWM visibility by tracing the prediction line over RWM was significantly associated with intraoperative RWM visibility.
Conclusion
The goal to look for preoperative scans is to predict the ease or difficulty of RWM visibility during surgery. The difficult visualization of the RWM, can result in dire intraoperative consequences. A comprehensive understanding of preoperative radiological parameters, coupled with meticulous surgical planning, is crucial to address these challenges effectively by focusing on enhancing RWM visualization.
Collapse