1
|
Generali L, Veneri F, Forabosco E, Cavani F, Piergianni V, Sassatelli P, Checchi V, Pedullà E. Push-out bond strength and SEM fractographical analysis of hollow fibre posts used with self-adhesive resin cement: a pilot study. Odontology 2024; 112:158-168. [PMID: 37173534 DOI: 10.1007/s10266-023-00820-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
Detachment is the major cause of failure of endodontic fibre posts. Hollow posts have been recently introduced to overcome such issue. The primary aim of this pilot study was to compare the push-out bond strength of hollow posts and traditional solid posts. Eight round-shaped single-canal premolars extracted for periodontal reason were selected as sample and equally randomized into two groups: (i) traditional solid fibre posts-TECH21xop and ii) hollow fibre posts-TECHOLE. A dual-curing self-adhesive cement (new TECHCEM) was used for posts placement. Six horizontal sections-two from each portion of the root (coronal, middle and apical)-were obtained from each sample root, yielding a total of 24 sections for each group. Push-out test was performed on the sections and bond strength values were compared between groups and within each group. Scanning electron microscope (SEM) fractographical analysis was conducted on each section. Additional SEM and EDX analyses were performed on new samples of both posts, to assess fibres density and distribution, and the chemical composition of the fibres and the matrix. Hollow posts showed a significantly higher push-out bond strength (6.36 ± 1.22 MPa) than solid posts (3.64 ± 1.62 MPa). Among the three root portions of the same group, there was no significant difference in bond strength. In both groups, the most frequent type of fracture was a mixed adhesive failure with the cement covering 0 to 50% of the post perimeter. Hollow post fibres appear more similar in size and have a more homogeneous distribution, compared to solid posts. The two post types also have different chemical compositions.
Collapse
Affiliation(s)
- Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Largo del Pozzo, 71, 41124, Modena, Italy.
| | - Federica Veneri
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Largo del Pozzo, 71, 41124, Modena, Italy
- PhD Program in Clinical and Experimental Medicine, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Eleonora Forabosco
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Largo del Pozzo, 71, 41124, Modena, Italy
- PhD Program in Clinical and Experimental Medicine, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | - Francesco Cavani
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
| | | | | | - Vittorio Checchi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Largo del Pozzo, 71, 41124, Modena, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
2
|
Abstract
The purpose of this study was to assess the effect of pre-etching time and material on shear bond strength (SBS) of self-adhesive resin cements to eroded and sound enamel. Eroded enamel specimens were assigned into 5 groups (n=20 each) based on enamel surface treatment as follow: Group N, eroded enamel (without surface pre-treatment); Group PH15, 35% H3PO4 etching for 15 s; Group PH30, 35% H3PO4 etching for 30 s; Group L30, 20% lactic acid etching for 30 s and Group L60, 20% lactic acid etching for 60 s.Composite blocks were fabricated and cemented to enamel surfaces with one of two self-adhesive cements. Notched-edge SBS was assessed. Bond strength of self-adhesive cement to eroded enamel surface significantly enhanced following application of 20% lactic acid for 30 s.
Collapse
Affiliation(s)
- Samah Saker
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University
| | - Mutlu Özcan
- Dental Materials Unit, Center for Dental and Oral Medicine Clinic for Fixed and Removable Prosthodontics and Dental Materials Science
| | - Walid Al-Zordk
- Fixed Prosthodontics Department, Faculty of Dentistry, Mansoura University
| |
Collapse
|
3
|
Rohr N, Fischer J. Effect of aging and curing mode on the compressive and indirect tensile strength of resin composite cements. Head Face Med 2017; 13:22. [PMID: 29162139 PMCID: PMC5697404 DOI: 10.1186/s13005-017-0155-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 11/15/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Resin composite cements are used in dentistry to bond ceramic restorations to the tooth structure. In the oral cavity these cements are subjected to aging induced by masticatory and thermal stresses. Thermal cycling between 5 and 55 °C simulates the effect of varying temperatures in vitro. Purpose of this study was to compare indirect tensile to compressive strength of different cements before and after thermal cycling. The effect of the curing mode was additionally assessed. METHODS Indirect tensile strength and compressive strength of 7 dual-curing resin composite cements (Multilink Automix, Multilink SpeedCem, RelyX Ultimate, RelyX Unicem 2 Automix, Panavia V5, Panavia SA Plus, Harvard Implant semi-permanent) was measured. The specimens were either autopolymerized or light-cured (n = 10). The mechanical properties were assessed after 24 h water storage at 37 °C and after aging (20,000 thermo cycles) with previous 24 h water storage at 37 °C. RESULTS Indirect tensile strength ranged from 5.2 ± 0.8 to 55.3 ± 4.2 MPa, compressive strength from 35.8 ± 1.8 MPa to 343.8 ± 19.6 MPa. CONCLUSIONS Thermocyclic aging of 20,000 cycles can be considered a suitable method to simulate the degradation of indirect tensile strength but not compressive strength of resin composite cements. The effect of thermocycling and the curing mode on the resin composite cements is material dependent and cannot be generalized.
Collapse
Affiliation(s)
- Nadja Rohr
- Division of Materials Science and Engineering, Clinic for Reconstructive Dentistry and Temporomandibular Disorders, University Center for Dental Medicine, Hebelstrasse 3, CH-4056, Basel, Switzerland.
| | - Jens Fischer
- Division of Materials Science and Engineering, Clinic for Reconstructive Dentistry and Temporomandibular Disorders, University Center for Dental Medicine, Hebelstrasse 3, CH-4056, Basel, Switzerland
| |
Collapse
|
4
|
Lawaf S, Jalalian E, Roshan R, Azizi A. Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement. J Adv Prosthodont 2016; 8:404-410. [PMID: 27826391 PMCID: PMC5099133 DOI: 10.4047/jap.2016.8.5.404] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 07/20/2016] [Accepted: 08/08/2016] [Indexed: 12/02/2022] Open
Abstract
PURPOSE Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS The mean tensile bond strength was significantly higher in the GLUMA desensitizer group (230.63 ± 63.8 N) compared to the control group (164.45 ± 39.3 N) (P≤.012). CONCLUSION GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.
Collapse
Affiliation(s)
- Shirin Lawaf
- Prosthodontics Department. Islamic Azad University-Dental Branch, Teheran, Iran
| | - Ezatallah Jalalian
- Prosthodontics Department. Islamic Azad University-Dental Branch, Teheran, Iran
| | - Roshanak Roshan
- Prosthodontics Department. Islamic Azad University-Dental Branch, Teheran, Iran
| | - Arash Azizi
- Oral Medicine Department. Islamic Azad University-Dental Branch, Teheran, Iran
| |
Collapse
|
5
|
Turp V, Sen D, Tuncelli B, Ozcan M. Adhesion of 10-MDP containing resin cements to dentin with and without the etch-and-rinse technique. J Adv Prosthodont 2013; 5:226-33. [PMID: 24049562 PMCID: PMC3774935 DOI: 10.4047/jap.2013.5.3.226] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 07/16/2013] [Accepted: 08/07/2013] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS Human third molars (N=180) were randomly divided into 6 groups (n=30 per group). Conventional (Panavia F2.0, Kuraray-PAN) and self-adhesive resin cements (Clearfil SA, Kuraray-CSA) were bonded to dentin surfaces either after application of 3-step etch-and-rinse (35% H3PO4 + ED Primer) or two-step self-etch adhesive resin (Clearfil SE Bond). Specimens were subjected to shear bond strength test using the universal testing machine (0.5 mm/min). The failure types were analyzed using a stereomicroscope and quality of hybrid layer was observed under a scanning electron microscope. The data (MPa) were analyzed using two-way ANOVA and Tukey's tests (α=.05). RESULTS Overall, PAN adhesive cement showed significantly higher mean bond strength (12.5 ± 2.3 - 14.1 ± 2.4 MPa) than CSA cement (9.3 ± 1.4 - 13.9 ± 1.9 MPa) (P<.001). Adhesive failures were more frequent in CSA cement groups when used in conjunction with two-step self-adhesive (68%) or no adhesive at all (66%). Hybrid layer quality was inferior in CSA compared to PAN cement in all conditions. CONCLUSION In clinical situations where bonding to dentin substrate is crucial, both conventional and self-adhesive resin cements based on 10-MDP can benefit from etch-and-rinse technique to achieve better quality of adhesion in the early clinical period.
Collapse
Affiliation(s)
- Volkan Turp
- University of Istanbul, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | | | | | | |
Collapse
|