1
|
Wei H, Yoon JH, Jeon SK, Choi JW, Lee J, Kim JH, Nickel MD, Song B, Duan T, Lee JM. Enhancing gadoxetic acid-enhanced liver MRI: a synergistic approach with deep learning CAIPIRINHA- VIBE and optimized fat suppression techniques. Eur Radiol 2024:10.1007/s00330-024-10693-9. [PMID: 38492004 DOI: 10.1007/s00330-024-10693-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 02/02/2024] [Accepted: 02/18/2024] [Indexed: 03/18/2024]
Abstract
OBJECTIVE To investigate whether a deep learning (DL) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE) technique can improve image quality, lesion conspicuity, and lesion detection compared to a standard CAIPIRINHA-VIBE technique in gadoxetic acid-enhanced liver MRI. METHODS This retrospective single-center study included 168 patients who underwent gadoxetic acid-enhanced liver MRI at 3 T using both standard CAIPIRINHA-VIBE and DL CAIPIRINHA-VIBE techniques on pre-contrast and hepatobiliary phase (HBP) images. Additionally, high-resolution (HR) DL CAIPIRINHA-VIBE was obtained with 1-mm slice thickness on the HBP. Three abdominal radiologists independently assessed the image quality and lesion conspicuity of pre-contrast and HBP images. Statistical analyses involved the Wilcoxon signed-rank test for image quality assessment and the generalized estimation equation for lesion conspicuity and detection evaluation. RESULTS DL and HR-DL CAIPIRINHA-VIBE demonstrated significantly improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE (p < 0.001), with a shorter acquisition time (DL vs standard, 11 s vs 17 s). However, the former presented a more synthetic appearance (both p < 0.05). HR-DL CAIPIRINHA-VIBE showed superior lesion conspicuity to standard and DL CAIPIRINHA-VIBE on HBP images (p < 0.001). Moreover, HR-DL CAIPIRINHA-VIBE exhibited a significantly higher detection rate of small (< 2 cm) solid focal liver lesions (FLLs) on HBP images compared to standard CAIPIRINHA-VIBE (92.5% vs 87.4%; odds ratio = 1.83; p = 0.036). CONCLUSION DL and HR-DL CAIPIRINHA-VIBE achieved superior image quality compared to standard CAIPIRINHA-VIBE. Additionally, HR-DL CAIPIRINHA-VIBE improved the lesion conspicuity and detection of small solid FLLs. DL and HR-DL CAIPIRINHA-VIBE hold the potential clinical utility for gadoxetic acid-enhanced liver MRI. CLINICAL RELEVANCE STATEMENT DL and HR-DL CAIPIRINHA-VIBE hold promise as potential alternatives to standard CAIPIRINHA-VIBE in routine clinical liver MRI, improving the image quality and lesion conspicuity, enhancing the detection of small (< 2 cm) solid focal liver lesions, and reducing the acquisition time. KEY POINTS • DL and HR-DL CAIPIRINHA-VIBE demonstrated improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE, in addition to a shorter acquisition time. • DL and HR-DL CAIPIRINHA-VIBE yielded a more synthetic appearance than standard CAIPIRINHA-VIBE. • HR-DL CAIPIRINHA-VIBE showed improved lesion conspicuity than standard CAIPIRINHA-VIBE on HBP images, with a higher detection of small (< 2 cm) solid focal liver lesions.
Collapse
Affiliation(s)
- Hong Wei
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea
| | - Sun Kyung Jeon
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Jae Won Choi
- Department of Radiology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea
- Department of Radiology, Armed Forces Yangju Hospital, Yangju, 482863, Republic of Korea
| | - Jihyuk Lee
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Jae Hyun Kim
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Marcel Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, Henkestr. 127, 91052, Erlangen, Germany
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
- Department of Radiology, Sanya People's Hospital, Sanya, 572000, Hainan, China
| | - Ting Duan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea.
| |
Collapse
|
2
|
Watura C, Mitchell AWM, Fahy D, Houghton J, Kang S, Lee JC. T1- VIBE and STIR MRI of lumbar pars interarticularis injuries in elite athletes: fracture characterisation and potential prognostic indicators. Skeletal Radiol 2024; 53:489-497. [PMID: 37650925 DOI: 10.1007/s00256-023-04437-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVES To assess how pars interarticularis fracture characteristics on T1-VIBE and STIR MRI relate to healing and identify anatomical parameters that may impact healing. MATERIALS AND METHODS A retrospective review of an MRI series of lumbar pars interarticularis injuries in elite athletes over a 3-year period. Fracture configurations, signal intensities and anatomical parameters were recorded by two radiologists. Statistical analysis employed multilevel mixed-effects linear regressions, adjusted for repeated measures and baseline covariates. RESULTS Forty-seven lumbar pars interarticularis injuries among 31 athletes were assessed. On final scans for each athlete, 15% (7/47) injuries had worsened, 23% (11/47) remained stable, 43% (20/47) partially healed and 19% (9/47) healed completely. Healing times varied, quickest was 49 days for a chronic fracture in a footballer. Bone marrow oedema signal was highest in worsened fractures, followed by improved, and lowest in stable fractures. As healing progressed, T1-VIBE signal at the fracture line decreased. Bone marrow oedema and fracture line signal peaked at 90-120 days before decreasing until 210-240 days. Fractures with smaller dimensions, more vertical orientation and a longer superior articular facet beneath were significantly associated with better healing (p < 0.05). CONCLUSION Most diagnosed athletic pars interarticularis injuries improve. Normalising T1-VIBE signal at the fracture line is a novel measurable indicator of bony healing. Contrastingly, bone marrow oedema signal is higher in active fractures irrespective of healing or deterioration. Injuries initially perceived as worsening may be exhibiting the normal osteoclastic phase of healing. Better outcomes favour smaller, vertical fractures with a longer superior articular facet beneath.
Collapse
Affiliation(s)
| | | | - Damian Fahy
- Fortius Clinic, 17 Fitzhardinge Street, London, W1H 6EQ, UK
| | | | - Sujin Kang
- Research Department, Chelsea and Westminster Hospital NHS Foundation Trust, London, UK
| | - Justin C Lee
- Fortius Clinic, 17 Fitzhardinge Street, London, W1H 6EQ, UK
| |
Collapse
|
3
|
KV A, Arunachalam VK, Sherene H, Ethiraju V, Ranganathan R, SM G, Rajasekaran S, Mehta P, Cherian M. Comparison of Contrast-Enhanced 3D Imaging with 2D Imaging in the Evaluation of Perianal Fistula at 3T: A Prospective Observational Study. Indian J Radiol Imaging 2024; 34:95-102. [PMID: 38106872 PMCID: PMC10723969 DOI: 10.1055/s-0043-1775738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023] Open
Abstract
Introduction Perianal fistula and its recurrence is a challenging entity for surgeons. It is a well-establi1shed fact that magnetic resonance imaging (MRI) findings influence surgical procedures and reduce the rate of recurrence. In this study, we assessed the contrast-enhanced (CE) three dimensional T1 sequences [sampling perfection with application optimized contrast using different flip angle evolution (SPACE) and volumetric interpolated breath-hold examination (VIBE)] in a 3T MRI system to evaluate perianal fistulas and compared them with two-dimensional (2D) sequences. Materials and Methods Forty-four patients (mean age, 38.8 ± 15.3 [standard deviation]; 32 males, 12 females) with perianal fistula were included in this prospective study. The patients underwent conventional noncontrast, 2D sequences, diffusion-weighted imaging, followed by postcontrast, 2D T1 images in both axial and coronal planes, and 3D sequences at 3T. Acquisition times were recorded for each sequence. Each postcontrast sequence was evaluated in terms of image quality, presence of artifacts, fistula type, presence of an abscess, visibility, and number of internal orifices. The surgical findings were considered the gold standard. The imaging findings were compared with the surgical findings. Results In all three sequences, the fistula type and abscess were identified correctly in all patients. The sensitivity value for identification of ramifications utilizing CE 3D T1 VIBE sequence, CE 3D T1 SPACE, and CE 2D T1 images was 100, 86, and 36%, respectively. The number of internal orifices was identified by the CE 3D T1 VIBE and CE 3D T1 SPACE sequences in 100 and 92% of patients, respectively. CE 2D T1 images correctly identified internal orifices in 80% of patients. The overall scan time for each 3D sequence was shorter than for the combined postcontrast 2D sequences. Conclusion CE 3D T1 SPACE and CE 3D T1 VIBE sequences outperformed conventional CE 2D sequences in the evaluation of perianal fistulas in terms of visibility and the number of internal orifices with a shorter scanning time. Among the 3D sequences, CE 3D T1 VIBE is slightly superior to CE 3D T1 SPACE sequence.
Collapse
Affiliation(s)
- Abdulla KV
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | | | - Haleema Sherene
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Vijayakumaran Ethiraju
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Rupa Ranganathan
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Gowtham SM
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Sriman Rajasekaran
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Pankaj Mehta
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| | - Mathew Cherian
- Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India
| |
Collapse
|
4
|
Sanchez F, Tyrrell PN, Cheung P, Heyn C, Graham S, Poon I, Ung Y, Louie A, Tsao M, Oikonomou A. Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo. Cancer Imaging 2023; 23:17. [PMID: 36793094 PMCID: PMC9933280 DOI: 10.1186/s40644-023-00531-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 02/04/2023] [Indexed: 02/17/2023] Open
Abstract
BACKGROUND Although MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE, Volumetric interpolated breath-hold examination), ultrashort time echo (UTE) and T2 Fast Spin Echo (HASTE, Half fourier Single-shot Turbo spin-Echo). METHODS Patients underwent a lung MRI in a 3 T scanner as part of a prospective research project. A baseline Chest CT was obtained as part of their standard of care. Nodules were identified and measured on the baseline CT and categorized according to their density (solid and subsolid) and size (> 4 mm/ ≤ 4 mm). Nodules seen on the baseline CT were classified as present or absent on the different MRI sequences by two thoracic radiologists independently. Interobserver agreement was determined using the simple Kappa coefficient. Paired differences were compared using nonparametric Mann-Whitney U tests. The McNemar test was used to evaluate paired differences in nodule detection between MRI sequences. RESULTS Thirty-six patients were prospectively enrolled. One hundred forty-nine nodules (100 solid/49 subsolid) with mean size 10.8 mm (SD = 9.4) were included in the analysis. There was substantial interobserver agreement (k = 0.7, p = 0.05). Detection for all nodules, solid and subsolid nodules was respectively; UTE: 71.8%/71.0%/73.5%; VIBE: 61.6%/65%/55.1%; HASTE 72.4%/72.2%/72.7%. Detection rate was higher for nodules > 4 mm in all groups: UTE 90.2%/93.4%/85.4%, VIBE 78.4%/88.5%/63.4%, HASTE 89.4%/93.8%/83.8%. Detection of lesions ≤4 mm was low for all sequences. UTE and HASTE performed significantly better than VIBE for detection of all nodules and subsolid nodules (diff = 18.4 and 17.6%, p = < 0.01 and p = 0.03, respectively). There was no significant difference between UTE and HASTE. There were no significant differences amongst MRI sequences for solid nodules. CONCLUSIONS Lung MRI shows adequate performance for the detection of solid and subsolid pulmonary nodules larger than 4 mm and can serve as a promising radiation-free alternative to CT.
Collapse
Affiliation(s)
- Felipe Sanchez
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Pascal N. Tyrrell
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Department of Statistical Sciences, Institute of Medical Science, University of Toronto, 263 McCaul Street, Toronto, Ontario M5T 1WT Canada
| | - Patrick Cheung
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Chinthaka Heyn
- grid.17063.330000 0001 2157 2938Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Simon Graham
- grid.17063.330000 0001 2157 2938Physical Sciences Platform of Sunnybrook Research Institute, Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Ian Poon
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Yee Ung
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Alexander Louie
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - May Tsao
- grid.17063.330000 0001 2157 2938Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 Canada
| | - Anastasia Oikonomou
- Department of Medical Imaging, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario, M4N 3M5, Canada.
| |
Collapse
|
5
|
Maennlin S, Wessling D, Herrmann J, Almansour H, Nickel D, Kannengiesser S, Afat S, Gassenmaier S. Application of deep learning-based super-resolution to T1-weighted postcontrast gradient echo imaging of the chest. Radiol Med 2023; 128:184-90. [PMID: 36609662 DOI: 10.1007/s11547-022-01587-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 12/30/2022] [Indexed: 01/09/2023]
Abstract
OBJECTIVES A deep learning-based super-resolution for postcontrast volume-interpolated breath-hold examination (VIBE) of the chest was investigated in this study. Aim was to improve image quality, noise, artifacts and diagnostic confidence without change of acquisition parameters. MATERIALS AND METHODS Fifty patients who received VIBE postcontrast imaging of the chest at 1.5 T were included in this retrospective study. After acquisition of the standard VIBE (VIBES), a novel deep learning-based algorithm and a denoising algorithm were applied, resulting in enhanced images (VIBEDL). Two radiologists qualitatively evaluated both datasets independently, rating sharpness of soft tissue, vessels, bronchial structures, lymph nodes, artifacts, cardiac motion artifacts, noise levels and overall diagnostic confidence, using a Likert scale ranging from 1 to 4. In the presence of lung lesions, the largest lesion was rated regarding sharpness and diagnostic confidence using the same Likert scale as mentioned above. Additionally, the largest diameter of the lesion was measured. RESULTS The sharpness of soft tissue, vessels, bronchial structures and lymph nodes as well as the diagnostic confidence, the extent of artifacts, the extent of cardiac motion artifacts and noise levels were rated superior in VIBEDL (all P < 0.001). There was no significant difference in the diameter or the localization of the largest lung lesion in VIBEDL compared to VIBES. Lesion sharpness as well as detectability was rated significantly better by both readers with VIBEDL (both P < 0.001). CONCLUSION The application of a novel deep learning-based super-resolution approach in T1-weighted VIBE postcontrast imaging resulted in an improvement in image quality, noise levels and diagnostic confidence as well as in a shortened acquisition time.
Collapse
|
6
|
Abstract
PURPOSE With the advancement of extended endonasal approaches, the ability to surgically reach parasellar tumor extensions increase. The aim of the study was to propose an optimized imaging protocol for surgical guidance in the cavernous sinus (CS) for proper visualization structures at risk. METHODS Prospective case control analysis of 20 consecutive pituitary adenoma patients scheduled for endoscopic transnasal surgery. Assessment of the capability of three different MRI sequences (MPRAGE, VIBE, CISS) by 4 investigators to correctly visualize sellar and parasellar structures. Invasiveness and position of the normal pituitary gland were compared with the intraoperative findings. RESULTS The consensus between the 4 examiners to achieve the same results for all modalities was 40% for MPRAGE, 70% for VIBE and 60% for CISS sequences (p = 0.155). A consensus of Knosp Grade per patient was 80% for MPRAGE, 100% for VIBE and 90% for CISS (overall kappa 0.60). A higher Knosp Grade was found in MPRAGE sequences compared to the other sequences. Intraoperative status of invasiveness was correctly identified in 12/20 (60%) with MPRAGE, 19/20 (95%) with VIBE and 11/20 (55%) with CISS sequences. The position of the normal pituitary gland was most frequent evaluable in 15/20 (75%) and correctly identified in 12/15 (80%) cases. CONCLUSION Our data showed that VIBE sequences obtain the highest degree of consensus with intraoperative findings of invasiveness and position of the normal pituitary gland. VIBE sequences, due to their high spatial resolution and at the same time fast image acquisition could provide improved imaging for neuronavigation.
Collapse
Affiliation(s)
- Alexander Micko
- Department of Neurosurgery, Medical University of Vienna, Waehringer Guertel 18-20, 1097, Vienna, Austria
| | - Arthur Hosmann
- Department of Neurosurgery, Medical University of Vienna, Waehringer Guertel 18-20, 1097, Vienna, Austria
| | - Wolfgang Marik
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Sophie Bartsch
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Michael Weber
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Engelbert Knosp
- Department of Neurosurgery, Medical University of Vienna, Waehringer Guertel 18-20, 1097, Vienna, Austria
| | - Stefan Wolfsberger
- Department of Neurosurgery, Medical University of Vienna, Waehringer Guertel 18-20, 1097, Vienna, Austria.
| |
Collapse
|
7
|
Lang M, Silva D, Dai L, Kshettry VR, Woodard TD, Sindwani R, Recinos PF. Superiority of constructive interference in steady-state MRI sequencing over T1-weighted MRI sequencing for evaluating cavernous sinus invasion by pituitary macroadenomas. J Neurosurg 2018; 130:1-8. [PMID: 29570007 DOI: 10.3171/2017.9.jns171699] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2017] [Accepted: 09/11/2017] [Indexed: 11/06/2022]
Abstract
OBJECTIVEPreoperatively determining the extent of parasellar invasion of pituitary macroadenomas is useful for surgical planning and patient counseling. Here, the authors compared constructive interference in steady state (CISS), a T2-weighted gradient-echo MRI sequence, to volume-interpolated breath-hold examination (VIBE), a T1-weighted gradient-echo MRI sequence, for evaluation of cavernous sinus invasion (CSI) by pituitary macroadenomas.METHODSVIBE and CISS images of 98 patients with pituitary macroadenoma were retrospectively analyzed and graded using the modified Knosp classification. The Knosp grades were correlated to surgical findings of CSI, which were determined intraoperatively using 0° and 30° endoscopes. The predictive accuracies for CSI according to the Knosp grades derived from the CISS and VIBE images were compared using receiver operating characteristic (ROC) curves. Postoperative MRI was used to evaluate the gross-total resection (GTR) rates.RESULTSThe CSI rate by pituitary macroadenomas was 27.6% (27 of 98 cases). Of 196 assessments (left and right sides of 98 macroadenomas), 45 (23.0%) had different Knosp grades when scored using VIBE versus CISS images. For the VIBE images, 0% of Knosp grade 0, 4.5% of grade 1, 23.8% of grade 2, 42.1% of grade 3A, 100% of grade 3B, and 83.3% of grade 4 macroadenomas were found to have CSI intraoperatively. For the CISS images, 0% of Knosp grade 0, 2.1% of grade 1, 31.3% of grade 2, 56.3% of grade 3A, 100% of grade 3B, and 100% of grade 4 macroadenomas were found to have CSI intraoperatively. Two pituitary macroadenomas were classified as grade 4 on VIBE sequences but grades 3A and 2 on CISS sequences; CSI was not observed intraoperatively in both cases. The GTR rate was 64.3% and 60.0% for high-grade (3A, 3B, and 4) macroadenomas classified using VIBE and CISS sequences, respectively. The areas under the ROC curves were 0.94 and 0.97 for VIBE- and CISS-derived Knosp grades (p = 0.007), respectively.CONCLUSIONSKnosp grades determined using CISS sequence images are better correlated with intraoperative CSI than those determined using VIBE sequence images. CISS sequences may be valuable for the preoperative assessment of pituitary macroadenomas.
Collapse
Affiliation(s)
- Min Lang
- 1School of Medicine, Case Western Reserve University
- 3Department of Neurosurgery, Neurological Institute
| | - Danilo Silva
- 3Department of Neurosurgery, Neurological Institute
- 5Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| | - Lu Dai
- 2Cleveland Clinic Lerner College of Medicine, Case Western Reserve University, Cleveland Clinic
| | - Varun R Kshettry
- 2Cleveland Clinic Lerner College of Medicine, Case Western Reserve University, Cleveland Clinic
- 5Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| | - Troy D Woodard
- 3Department of Neurosurgery, Neurological Institute
- 5Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| | - Raj Sindwani
- 3Department of Neurosurgery, Neurological Institute
- 5Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| | - Pablo F Recinos
- 2Cleveland Clinic Lerner College of Medicine, Case Western Reserve University, Cleveland Clinic
- 5Section of Rhinology, Sinus, and Skull Base Surgery, Head and Neck Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
8
|
Deepho C, Watanabe H, Sakamoto J, Kurabayashi T. Mandibular canal visibility using a plain volumetric interpolated breath-hold examination sequence in MRI. Dentomaxillofac Radiol 2017; 47:20170245. [PMID: 28959898 DOI: 10.1259/dmfr.20170245] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To evaluate the validity of plain volumetric interpolated breath-hold examinations (VIBEs) for detecting the course of the mandibular canal, and to compare the results with contrast-enhanced (CE) VIBE images. METHODS From our imaging archives, we collected 28 cases taken with a VIBE sequence both before and after intravenous administration of gadolinium hydrate, and then two observers evaluated neurovascular bundle (NVB) visibility in the VIBE images. For the invisible NVB cases, we identified the invisible areas and analysed the causes of invisibility. For cases that also had corresponding CT thin slice images, we obtained a fusion image between MRI and CT, and investigated the relationship between the NVB in VIBE and the mandibular canal in CT images. RESULTS The visibility of the NVBs in plain VIBE was 89%, the same as on CE VIBE. There were three invisible cases in each plain and CE VIBE images. The invisible areas were premolar in three cases, and molar in one case, and the causes of the invisibility were a metallic artefact in one case and motion artefacts in the other two cases. CONCLUSIONS A plain VIBE can depict the NVB at the same rate as CE VIBE, and is suitable for detecting NVBs.
Collapse
Affiliation(s)
- Chutamas Deepho
- 1 Department of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan
| | - Hiroshi Watanabe
- 1 Department of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan
| | - Junichiro Sakamoto
- 1 Department of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tohru Kurabayashi
- 1 Department of Oral and Maxillofacial Radiology, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
9
|
Gottsegen CJ, Merkle AN, Bencardino JT, Gyftopoulos S. Advanced MRI Techniques of the Shoulder Joint: Current Applications in Clinical Practice. AJR Am J Roentgenol 2017; 209:544-51. [PMID: 28829170 DOI: 10.2214/AJR.17.17945] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE We are fortunate to live in a time when real advances in medicine are happening at an increasingly rapid pace. This is especially true in the field of radiology, and keeping abreast of these advances is one of the main challenges of clinical practice. Traditionally, cutting edge techniques in our field have been researched and validated at major academic medical centers before slowly making their way into the armamentarium of routine clinical practice. However, the improved ability to communicate and disseminate information in our modern age has facilitated more rapid implementation of new techniques to allow us to better serve our patients. CONCLUSION As such, this article aims to review the current standards for MRI of the shoulder used in routine practice. Furthermore, we will discuss some of the most recent advances in shoulder MRI, with particular emphasis on the applicability of an additional axial 3D T1-weighted FLASH sequence with Dixon-based water-fat separation in routine clinical practice that can be useful in characterizing several commonly encountered pathologic processes of the shoulder joint.
Collapse
|
10
|
Cho HH, Choi YH, Cheon JE, Lee SM, Kim WS, Kim IO, Paek M. Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence. AJR Am J Roentgenol 2016; 207:177-82. [PMID: 27070492 DOI: 10.2214/AJR.15.15617] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to compare free-breathing radially sampled 3D T1-weighted gradient-echo acquisitions (radial volumetric interpolated breath-hold examination [VIBE]) with a T1-weighted turbo spin-echo (TSE) sequence for contrast-enhanced spinal imaging of children with CNS tumors. MATERIALS AND METHODS Twenty-eight consecutively registered children with CNS tumors underwent evaluation of leptomeningeal seeding with 1.5-T MRI that included both radial VIBE and T1-weighted TSE sequences. For qualitative analysis, overall image quality; presence of motion, CSF flow, and radial artifacts; and lesion conspicuity were retrospectively assessed with scoring systems. The signal-intensity uniformity of each sequence was evaluated for quantitative comparison. The acquisition times for each sequence were compared. RESULTS Images obtained with the radial VIBE sequence had a higher overall image quality score than did T1-weighted TSE images (3.61 ± 0.73 vs 2.80 ± 0.69, p < 0.001) and lower motion artifact (0.82 ± 0.43 vs 1.29 ± 0.56, p = 0.001) and CSF flow artifact (0 vs 1.68 ± 0.67, p < 0.001) scores. Radial artifacts were found only on radial VIBE images (1.36 ± 0.31 vs 0, p < 0.001). In 13 patients with spinal seeding nodules, radial VIBE images showed greater lesion conspicuity than did T1-weighted TSE images (4.23 ± 0.52 vs 2.47 ± 0.57, p = 0.005). Radial VIBE images had diminished signal-intensity variation compared with T1-weighted TSE images in air, spine, and muscle (p < 0.01). The mean acquisition times were not significantly different between the two sequences (p = 0.117). CONCLUSION For pediatric spinal imaging, radial VIBE images had better image quality and lesion conspicuity and fewer CSF and respiratory motion artifacts than did T1-weighted TSE images in a similar acquisition time.
Collapse
|