Abstract
PURPOSE
To describe a surgical approach using intraoperative optical coherence tomography and endoscopy for successful Argus II retinal prosthesis system removal.
METHODS
Retrospective review of a patient undergoing Argus II explantation 8 months after initial implantation.
RESULTS
Successful explantation of the Argus II device was performed in this patient.
CONCLUSION
Explantation of the Argus II device can be a difficult surgery, and intraoperative optical coherence tomography and endoscopy can be used to help avoid potential complications.