Taniguchi H, Yoshimoto N, Okazaki K. Awareness of Stress Concentration Points for Prevention and Management of Periprosthetic Fractures Following Plate Installation Reinforcement: A Case Report. J Orthop Case Rep 2023; 13:63-68. [PMID: 37654770 PMCID: PMC10465749 DOI: 10.13107/jocr.2023.v13.i08.3818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/20/2023] [Indexed: 09/02/2023] Open
Abstract
Introduction In an aging society, the incidence of periprosthetic fractures will increase owing to the increasing number of patients undergoing joint replacement surgery. We experienced a case of recurrent periprosthetic fracture in a patient who had undergone ipsilateral hip bipolar hemiarthroplasty (BHA) and total knee arthroplasty. Based on our experience, we discuss the treatment strategy for periprosthetic fractures in patients at a high risk of fall. Case Report An 84-year-old woman, who had undergone total knee arthroplasty 9 years ago and ipsilateral hip BHA 2 years ago, sustained a knee condylar fracture (Su classification type III) due to fall. This knee periprosthetic fracture posed a challenge for osteosynthesis; therefore, revision total knee arthroplasty was performed using a hinge-type prosthesis. During this surgery, we installed a reinforcement plate on the femoral shaft to prevent fractures because of the short stem tip distance between the hip and knee prosthesis (53 mm). The procedure was successful, and the patient regained her walking ability. However, 6 months after surgery, the patient sustained a hip periprosthetic fracture (Vancouver type B2) due to a fall, despite precautionary plate installation. In case of hip stem insertion, the stress caused by fall is concentrated on the infratrochanteric region, as reflected in her fracture site. From a mechanical perspective, this fracture was not accidental. The plate reinforcement procedure may have been inadequate because the top of the plate was located at the infratrochanteric region. Conclusion Periprosthetic fractures may occur despite the installation of a plate for fracture prevention. With a total hip arthroplasty or hip BHA stem inserted, a fall could result in a subtrochanteric fracture.
Collapse
Affiliation(s)
- Hiroto Taniguchi
- Department of Orthopaedic Surgery, Yachiyo Medical Center, Tokyo Women’s Medical University, Chiba, Japan
| | - Nobuyuki Yoshimoto
- Department of Orthopaedic Surgery, Yachiyo Medical Center, Tokyo Women’s Medical University, Chiba, Japan
| | - Ken Okazaki
- Department of Orthopaedic Surgery, Tokyo Women’s Medical University, Tokyo, Japan
| |
Collapse
|
2
|
Mühling M, Sandriesser S, Glowalla C, Herrmann S, Augat P, Hungerer S. Risk of Interprosthetic Femur Fracture Is Associated with Implant Spacing-A Biomechanical Study. J Clin Med 2023; 12:jcm12093095. [PMID: 37176537 PMCID: PMC10179557 DOI: 10.3390/jcm12093095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/13/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
BACKGROUND Ipsilateral revision surgeries of total hip or knee arthroplasties due to periprosthetic fractures or implant loosening are becoming more frequent in aging populations. Implants in revision arthroplasty usually require long anchoring stems. Depending on the residual distance between two adjacent knee and hip implants, we assume that the risk of interprosthetic fractures increases with a reduction in the interprosthetic distance. The aim of the current study was to investigate the maximum strain within the femoral shaft between two ipsilateral implants tips. METHODS A simplified physical model consisting of synthetic bone tubes and metallic implant cylinders was constructed and the surface strains were measured using digital image correlation. The strain distribution on the femoral shaft was analyzed in 3-point- and 4-point-bending scenarios. The physical model was transferred to a finite element model to parametrically investigate the effects of the interprosthetic distance and the cortical thickness on maximum strain. Strain patterns for all parametric combinations were compared to the reference strain pattern of the bone without implants. RESULTS The presence of an implant reduced principal strain values but resulted in distinct strain peaks at the locations of the implant tips. A reduced interprosthetic distance and thinner cortices resulted in strain peaks of up to 180% compared to the reference. At low cortical thicknesses, the strain peaks increased exponentially with a decrease in the interprosthetic distance. An increasing cortical thickness reduced the peak strains at the implant tips. CONCLUSIONS A minimum interprosthetic distance of 10 mm seems to be crucial to avoid the accumulation of strain peaks caused by ipsilateral implant tips. Interprosthetic fracture management is more important in patients with reduced bone quality.
Collapse
Affiliation(s)
- Mischa Mühling
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
- Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
| | - Sabrina Sandriesser
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
- Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
| | - Claudio Glowalla
- Department of Arthroplasty, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
| | - Sven Herrmann
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
- Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
| | - Peter Augat
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
- Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
| | - Sven Hungerer
- Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
- Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria
- Department of Arthroplasty, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany
| |
Collapse
|
3
|
Marzano F, Pace V, Donantoni M, Petruccelli R, Ceccarini P, Caraffa A, Di Giacomo LM. A Novel Approach to Treat a Rare Case of Interprosthetic Humeral Fracture with Osteosynthesis and Combined Grafting: A Case Report and Review of the Literature. J Funct Morphol Kinesiol 2022; 7. [PMID: 36412756 DOI: 10.3390/jfmk7040094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/19/2022] [Accepted: 10/20/2022] [Indexed: 12/14/2022] Open
Abstract
Interprosthetic humeral fractures (IHFs) are severe injury patterns associated with surgical issues and contradictory results. The knowledge and literature on this topic are still lacking. A 76 year-old woman was treated for a fracture occurred between the shoulder and elbow stemmed prosthesis. Severe bone loss was associated with the fracture. Treatment: Open reduction, plate fixation, and bone grafting were considered. A xenograft (used as a mechanical strut medially), a synthetic graft associated with bone growth factors, and scaffolds improved the bone healing process. Satisfactory clinical and radiological outcomes were obtained. A scoping review of the literature was also performed by the authors. Only eight papers reported IHFs with a low level of evidence. In total, eight patients were treated; one paper that reported on biomechanical aspects using finite element analysis is discussed. Conservative treatment leads to non-union, and the surgical approach is the gold standard. The osteosynthesis technique associated with bone grafting leads to the best outcomes. The use of a xenograft mechanical strut, associated with synthetic biological bone grafting, led to complete bone union at 9 months follow-up. Larger cohorts, more standardised results, and multicentric studies are mandatory in order to improve and establish a management and treatment algorithm.
Collapse
|
4
|
Güngörürler M, Gürsan O, Havıtçıoğlu H. Computational analysis of the effects of interprosthetic distance on normal and reduced cortical thickness femur models. Proc Inst Mech Eng H 2021; 236:169-178. [PMID: 34425723 DOI: 10.1177/09544119211040998] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Distal femoral fractures associated with the femoral stem in a well-fixed hip arthroplasty pose a risk of an interprosthetic fracture, the treatment of which is known as difficult. To effectively prevent and treat IP fractures, biomechanical effects must be demonstrated. We defined eight variations of the interprosthetic distance ranging from 48 mm overlap to 128 mm gap. Femoral geometries with normal and reduced cortical thickness were modeled to evaluate the effects of cortical thickness. In addition to the intact model, a total of 16 finite element models were analyzed under physiological boundary conditions. Maximum and minimum principal strains on the lateral and medial cortex surfaces were always found to be greater in models with reduced cortical thickness than in normal femurs. The model with 48 mm overlapping interprosthetic distance produced the least peak strain and the model with 16 mm interprosthetic gap produced the greatest strain with both normal and reduced cortical thickness. The screw holes produced local strain concentrations and increased the peak strains on the cortex surfaces, especially close to the stem tip. Statistically, a significant correlation (R2 = 0.9483) was found between strain shielding and interprosthetic distance. Axial stiffness, interfragmentary shear motion, and maximum von-Mises stress on the distal plate showed a high correlation with the interprosthetic distance. It was concluded that the overlapping structures are superior to other fixations we analyzed in that they offer better mechanical stability and eliminates the local strain concentrations.
Collapse
Affiliation(s)
- Musa Güngörürler
- Department of Biomechanics, School of Medicine Health Science Institute, Dokuz Eylul University, Izmir, Turkey
| | - Onur Gürsan
- Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Turkey
| | - Hasan Havıtçıoğlu
- Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Turkey
| |
Collapse
|
5
|
Loucas M, Loucas R, Akhavan NS, Fries P, Dietrich M. Interprosthetic Femoral Fractures Surgical Treatment in Geriatric Patients. Geriatr Orthop Surg Rehabil 2021; 12:21514593211013790. [PMID: 34017616 PMCID: PMC8114290 DOI: 10.1177/21514593211013790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 04/05/2021] [Accepted: 04/06/2021] [Indexed: 11/16/2022] Open
Abstract
Background Total hip (THA) and total knee arthroplasty (TKA) are becoming an increasingly standard procedure in the whole world. In conjunction with an aging population and increased prevalence of osteoporosis, proper management of periprosthetic, and interprosthetic fractures is of great interest to orthopedic surgeons. This study aims to report the clinical and radiographic outcomes, complications and reoperations of IFFs in geriatric patients. Methods A retrospective single-institution case series study was conducted. Between 2011 and 2019, 83 patients underwent surgical treatment for periprosthetic femoral fractures. Thirteen fractures were identified as IFFs. Patient demographics and comorbidities were collected preoperatively, and fractures were classified with the Vancouver and AO unified classification system (AO-UCS). Results We included 12 patients (13 hips) with IFFs (AO-UCS type IV.3 B (2/13) type IV.3 C (3/13), type IV.3 D (8/13)). The average patient age was 86.54 (range, 79-89) years. There were 10 females and 2 males. Perioperative morbidity has been identified in 10 of the 12 patients, and the 3-month and 1-year mortality were reported in 2 and 3 patients, respectively. Cerclage cables were used in 9 of 12 patients. One of 12 patients showed a local complication, with no documented implant failure or revision. Patients achieved complete union and returned to their preoperative ambulatory status, and full weight-bearing at an average of 5 (range, 2 to 7) months later. Conclusion Management of IFF can be challenging because these fractures require extensive surgical expertise. Locking plate seems to be a valuable treatment option for geriatric patients with IFFs. Despite the complexity of this type of fracture, the overall complication and revision rate, as well as the radiographic outcome are good to excellent. Level of Evidence Level III, Therapeutic study.
Collapse
Affiliation(s)
- Marios Loucas
- Department of Orthopedic Surgery, Handsurgery and Traumatology at City Hospital Waid and Triemli, Zurich, Switzerland.,Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Rafael Loucas
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Nico Safa Akhavan
- Department of Orthopedic Surgery, Handsurgery and Traumatology at City Hospital Waid and Triemli, Zurich, Switzerland
| | - Patrick Fries
- Department of Orthopedic Surgery, Handsurgery and Traumatology at City Hospital Waid and Triemli, Zurich, Switzerland
| | - Michael Dietrich
- Department of Orthopedic Surgery, Handsurgery and Traumatology at City Hospital Waid and Triemli, Zurich, Switzerland
| |
Collapse
|
6
|
Abdelaziz H, Saleri S, Mau H, Sandiford NA, Lausmann C, Zahar A, Gehrke T, Haasper C, Citak M. Interprosthetic Femoral Sleeves in Revision Arthroplasty: A 20-Year Experience. J Arthroplasty 2019; 34:1423-1429. [PMID: 30904363 DOI: 10.1016/j.arth.2019.02.055] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 02/18/2019] [Accepted: 02/25/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Interprosthetic femoral fractures in patients with ipsilateral stemmed total hip arthroplasty (THA) and total knee arthroplasty (TKA) can be technically demanding to treat surgically. Nonunion and implant failure are among the main complications following fixation of interprosthetic femoral (IF) fractures. Total femoral arthroplasty (TFA) is associated with a high incidence of infection and instability. IF sleeves have been designed to avoid the disadvantages of these techniques and to provide a stable construct. The aim of this study was to present the results with this device from a single center. METHODS We reviewed 26 patients who underwent revision arthroplasty procedures, using custom-made cemented IF sleeves between 1997 and December 2017 in our institution. Two-part sleeves were used in 18 patients and one-part sleeves in 8 patients. The most common indication was an IF fracture (18 patients). Patients were monitored for postoperative complications, implant failure, and re-revision. The minimum follow-up of the survivors with nonrevised sleeves was 12 months. RESULTS Twenty-three patients were included for the final analysis. The mean survivorship of the IF sleeve was 4.6 years at latest follow-up (mean 48.5 months; range 12 to 156). The overall rate of complications was 47.8%. The rate of mechanical failure was 21.7%. Late infections occurred in 3 patients (13%). At the latest follow-up, the mean Harris Hip Score was 69.9 points (range 39 to 94), and the mean functional Knee Society Score was 42.5 points (range 0 to 90), with average knee flexion of 95° (range 90° to 100°). CONCLUSION The IF sleeve is a valid technique for the management of selected patients with IF fractures, particularly when a stable fracture fixation is not possible. Hip instability is not a concern, and functional improvement is achievable. Careful planning is required preoperatively to avoid mechanical failure.
Collapse
Affiliation(s)
- Hussein Abdelaziz
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Solmaz Saleri
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Hans Mau
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | | | - Christian Lausmann
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Akos Zahar
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Carl Haasper
- Department of Orthopaedic Surgery, AMEOS Klinikum Seepark Geestland, Geestland, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| |
Collapse
|