1
|
Qu L, Li J, Du Y, Yang L, Ren X, Liu L, Liu X, Li Y, Wei Q. Designing Triangular Silver Nanoplates with GSH/GSSG Surface Mixed States as Novel Nanoparticle-based Redox Mediators for Electrochemical Biosensing. ACS Appl Mater Interfaces 2022; 14:26271-26278. [PMID: 35622712 DOI: 10.1021/acsami.2c05869] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Herein, a dual signal-quenched electrochemical (EC) biosensing strategy utilizing surface-engineered trisodium citrate (TSC)-glutathione (GSH)/oxidized glutathione (GSSG)-capped triangular silver nanoplates (Tri-Ag NPsTSC-GSH/GSSG) as a novel nanoparticle-based redox mediator was explored for biomarker determination. In contrast with conventional redox mediators, Tri-Ag NPsTSC-GSH/GSSG provided more admirable EC performance along with a lower oxidation potential (∼0.14 V). Taking advantage of the split-type mode, the immune response in a 96-well microplate was independent from EC detection, which could effectively eliminate the biological interference and thereby greatly enhance the sensitivity. As for the surface engineering process of Tri-Ag NPs, it was composed of partial GSH replacement and the formation of the GSH/GSSG surface mixed state. Primarily, the signal response of Ag NPsTSC-GSH decreased due to the hindrance of GSH on electron transfer. Moreover, varying proportions of GSH/GSSG could further impede the oxidation process of Tri-Ag NPsTSC-GSH/GSSG and eventually realize efficient dual signal quenching of this system. Notably, the ZIF-67@MIL-88B-GOx nanocomposite as the label was applied for a cascade reaction system with GSH peroxidase-like activities to form the optimal GSH/GSSG proportion, causing sensitive changes in signal response with a range of different antigen concentrations. On this basis, the fabricated biosensor provided measurable outputs of aflatoxin B1 concentrations in a linear range of 0.0005-50 ng/mL with a low detection limit of 0.61 pg/mL (S/N = 3). All of the results indicated that the novel biosensor could be a promising analytical tool for future biomarker detection.
Collapse
Affiliation(s)
- Liu Qu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Jingshuai Li
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Yu Du
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection of Shandong Province, University of Jinan, Jinan 250022, P. R. China
| | - Lei Yang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Xiang Ren
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Lei Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Xuejing Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Yuyang Li
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| |
Collapse
|