1
|
Remote optogenetic control of the enteric nervous system and brain-gut axis in freely-behaving mice enabled by a wireless, battery-free optoelectronic device. Biosens Bioelectron 2024; 258:116298. [PMID: 38701537 DOI: 10.1016/j.bios.2024.116298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 04/03/2024] [Accepted: 04/14/2024] [Indexed: 05/05/2024]
Abstract
Wireless activation of the enteric nervous system (ENS) in freely moving animals with implantable optogenetic devices offers a unique and exciting opportunity to selectively control gastrointestinal (GI) transit in vivo, including the gut-brain axis. Programmed delivery of light to targeted locations in the GI-tract, however, poses many challenges not encountered within the central nervous system (CNS). We report here the development of a fully implantable, battery-free wireless device specifically designed for optogenetic control of the GI-tract, capable of generating sufficient light over large areas to robustly activate the ENS, potently inducing colonic motility ex vivo and increased propulsion in vivo. Use in in vivo studies reveals unique stimulation patterns that increase expulsion of colonic content, likely mediated in part by activation of an extrinsic brain-gut motor pathway, via pelvic nerves. This technology overcomes major limitations of conventional wireless optogenetic hardware designed for the CNS, providing targeted control of specific neurochemical classes of neurons in the ENS and brain-gut axis, for direct modulation of GI-transit and associated behaviours in freely moving animals.
Collapse
|
2
|
A wirelessly programmable, skin-integrated thermo-haptic stimulator system for virtual reality. Proc Natl Acad Sci U S A 2024; 121:e2404007121. [PMID: 38768347 DOI: 10.1073/pnas.2404007121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Accepted: 04/13/2024] [Indexed: 05/22/2024] Open
Abstract
Sensations of heat and touch produced by receptors in the skin are of essential importance for perceptions of the physical environment, with a particularly powerful role in interpersonal interactions. Advances in technologies for replicating these sensations in a programmable manner have the potential not only to enhance virtual/augmented reality environments but they also hold promise in medical applications for individuals with amputations or impaired sensory function. Engineering challenges are in achieving interfaces with precise spatial resolution, power-efficient operation, wide dynamic range, and fast temporal responses in both thermal and in physical modulation, with forms that can extend over large regions of the body. This paper introduces a wireless, skin-compatible interface for thermo-haptic modulation designed to address some of these challenges, with the ability to deliver programmable patterns of enhanced vibrational displacement and high-speed thermal stimulation. Experimental and computational investigations quantify the thermal and mechanical efficiency of a vertically stacked design layout in the thermo-haptic stimulators that also supports real-time, closed-loop control mechanisms. The platform is effective in conveying thermal and physical information through the skin, as demonstrated in the control of robotic prosthetics and in interactions with pressure/temperature-sensitive touch displays.
Collapse
|
3
|
A Miniaturized, Battery-Free, Wireless Wound Monitor That Predicts Wound Closure Rate Early. Adv Healthc Mater 2023; 12:e2301280. [PMID: 37407030 PMCID: PMC10766868 DOI: 10.1002/adhm.202301280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/27/2023] [Accepted: 06/29/2023] [Indexed: 07/07/2023]
Abstract
Diabetic foot ulcers are chronic wounds that affect millions and increase the risk of amputation and mortality, highlighting the critical need for their early detection. Recent demonstrations of wearable sensors enable real-time wound assessment, but they rely on bulky electronics, making them difficult to interface with wounds. Herein, a miniaturized, wireless, battery-free wound monitor that measures lactate in real-time and seamlessly integrates with bandages for conformal attachment to the wound bed is introduced. Lactate is selected due to its multifaceted role in initiating healing. Studies in healthy and diabetic mice reveal distinct lactate profiles for normal and impaired healing wounds. A mathematical model based on the sensor data predicts wound closure rate within the first 3 days post-injury with ≈76% accuracy, which increases to ≈83% when pH is included. These studies underscore the significance of monitoring biomarkers during the inflammation phase, which can offer several benefits, including short-term use of wound monitors and their easy removal, resulting in lower risks of injury and infection at the wound site. Improvements in prediction accuracy can be achieved by designing mathematical models that build on multiple wound parameters such as pro-inflammatory and metabolic markers. Achieving this goal will require designing multi-analyte wound monitors.
Collapse
|
4
|
Bioresorbable, wireless, and battery-free system for electrotherapy and impedance sensing at wound sites. SCIENCE ADVANCES 2023; 9:eade4687. [PMID: 36812305 PMCID: PMC9946359 DOI: 10.1126/sciadv.ade4687] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 01/20/2023] [Indexed: 05/29/2023]
Abstract
Chronic wounds, particularly those associated with diabetes mellitus, represent a growing threat to public health, with additional notable economic impacts. Inflammation associated with these wounds leads to abnormalities in endogenous electrical signals that impede the migration of keratinocytes needed to support the healing process. This observation motivates the treatment of chronic wounds with electrical stimulation therapy, but practical engineering challenges, difficulties in removing stimulation hardware from the wound site, and absence of means to monitor the healing process create barriers to widespread clinical use. Here, we demonstrate a miniaturized wireless, battery-free bioresorbable electrotherapy system that overcomes these challenges. Studies based on a splinted diabetic mouse wound model confirm the efficacy for accelerated wound closure by guiding epithelial migration, modulating inflammation, and promoting vasculogenesis. Changes in the impedance provide means for tracking the healing process. The results demonstrate a simple and effective platform for wound site electrotherapy.
Collapse
|
5
|
Remote control of muscle-driven miniature robots with battery-free wireless optoelectronics. Sci Robot 2023; 8:eadd1053. [PMID: 36652505 DOI: 10.1126/scirobotics.add1053] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Bioengineering approaches that combine living cellular components with three-dimensional scaffolds to generate motion can be used to develop a new generation of miniature robots. Integrating on-board electronics and remote control in these biological machines will enable various applications across engineering, biology, and medicine. Here, we present hybrid bioelectronic robots equipped with battery-free and microinorganic light-emitting diodes for wireless control and real-time communication. Centimeter-scale walking robots were computationally designed and optimized to host on-board optoelectronics with independent stimulation of multiple optogenetic skeletal muscles, achieving remote command of walking, turning, plowing, and transport functions both at individual and collective levels. This work paves the way toward a class of biohybrid machines able to combine biological actuation and sensing with on-board computing.
Collapse
|
6
|
Wireless implantable optical probe for continuous monitoring of oxygen saturation in flaps and organ grafts. Nat Commun 2022; 13:3009. [PMID: 35637230 PMCID: PMC9151749 DOI: 10.1038/s41467-022-30594-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 05/04/2022] [Indexed: 12/24/2022] Open
Abstract
Continuous, real-time monitoring of perfusion after microsurgical free tissue transfer or solid organ allotransplantation procedures can facilitate early diagnosis of and intervention for anastomotic thrombosis. Current technologies including Doppler systems, cutaneous O2-sensing probes, and fluorine magnetic resonance imaging methods are limited by their intermittent measurements, requirements for skilled personnel, indirect interfaces, and/or their tethered connections. This paper reports a wireless, miniaturized, minimally invasive near-infrared spectroscopic system designed for uninterrupted monitoring of local-tissue oxygenation. A bioresorbable barbed structure anchors the probe stably at implantation sites for a time period matched to the clinical need, with the ability for facile removal afterward. The probe connects to a skin-interfaced electronic module for wireless access to essential physiological parameters, including local tissue oxygenation, pulse oxygenation, and heart rate. In vitro tests and in vivo studies in porcine flap and kidney models demonstrate the ability of the system to continuously measure oxygenation with high accuracy and sensitivity. Although continuous monitoring of tissue oxygenation is critically important after tissue/organ graft procedures, current technologies have key limitations. Here, the authors develop a miniaturized, minimally invasive, self-anchoring optical probe and demonstrate continuous monitoring of oxygenation in porcine flap and organ models.
Collapse
|
7
|
Abstract
Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.
Collapse
|
8
|
Preparation and use of wireless reprogrammable multilateral optogenetic devices for behavioral neuroscience. Nat Protoc 2022; 17:1073-1096. [PMID: 35173306 PMCID: PMC9311268 DOI: 10.1038/s41596-021-00672-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 12/01/2021] [Indexed: 11/08/2022]
Abstract
Wireless battery-free optogenetic devices enable behavioral neuroscience studies in groups of animals with minimal interference to natural behavior. Real-time independent control of optogenetic stimulation through near-field communication dramatically expands the realm of applications of these devices in broad contexts of neuroscience research. Dissemination of these tools with advanced functionalities to the neuroscience community requires protocols for device manufacturing and experimental implementation. This protocol describes detailed procedures for fabrication, encapsulation and implantation of recently developed advanced wireless devices in head- and back-mounted forms. In addition, procedures for standard implementation of experimental systems in mice are provided. This protocol aims to facilitate the application of wireless optogenetic devices in advanced optogenetic experiments involving groups of freely moving rodents and complex environmental designs. The entire protocol lasts ~3-5 weeks.
Collapse
|
9
|
OUP accepted manuscript. Natl Sci Rev 2022; 9:nwac016. [PMID: 36196123 PMCID: PMC9522382 DOI: 10.1093/nsr/nwac016] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 12/06/2021] [Accepted: 01/27/2022] [Indexed: 11/13/2022] Open
|
10
|
DNA-Modified Plasmonic Sensor for the Direct Detection of Virus Biomarkers from the Blood. NANO LETTERS 2021; 21:7505-7511. [PMID: 34496209 DOI: 10.1021/acs.nanolett.1c01609] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The rapid spread of viral infections demands early detection strategies to minimize proliferation of the disease. Here, we demonstrate a plasmonic biosensor to detect Dengue virus, which was chosen as a model, via its nonstructural protein NS1 biomarker. The sensor is functionalized with a synthetic single-stranded DNA oligonucleotide and provides high affinity toward NS1 protein present in the virus genome. We demonstrate the detection of NS1 protein at a concentration of 0.1-10 μg/mL in bovine blood using an on-chip microfluidic plasma separator integrated with the plasmonic sensor which covers the clinical threshold of 0.6 μg/mL of high risk of developing Dengue hemorrhagic fever. The conceptual and practical demonstration shows the translation feasibility of these microfluidic optical biosensors for early detection of a wide range of viral infections, providing a rapid clinical diagnosis of infectious diseases directly from minimally processed biological samples at point of care locations.
Collapse
|
11
|
Wireless multilateral devices for optogenetic studies of individual and social behaviors. Nat Neurosci 2021; 24:1035-1045. [PMID: 33972800 PMCID: PMC8694284 DOI: 10.1038/s41593-021-00849-x] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 03/26/2021] [Indexed: 12/31/2022]
Abstract
Advanced technologies for controlled delivery of light to targeted locations in biological tissues are essential to neuroscience research that applies optogenetics in animal models. Fully implantable, miniaturized devices with wireless control and power-harvesting strategies offer an appealing set of attributes in this context, particularly for studies that are incompatible with conventional fiber-optic approaches or battery-powered head stages. Limited programmable control and narrow options in illumination profiles constrain the use of existing devices. The results reported here overcome these drawbacks via two platforms, both with real-time user programmability over multiple independent light sources, in head-mounted and back-mounted designs. Engineering studies of the optoelectronic and thermal properties of these systems define their capabilities and key design considerations. Neuroscience applications demonstrate that induction of interbrain neuronal synchrony in the medial prefrontal cortex shapes social interaction within groups of mice, highlighting the power of real-time subject-specific programmability of the wireless optogenetic platforms introduced here.
Collapse
|
12
|
Author Correction: Recent advances in neurotechnologies with broad potential for neuroscience research. Nat Neurosci 2021; 24:611. [PMID: 33564171 DOI: 10.1038/s41593-021-00813-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
13
|
Wireless, implantable catheter-type oximeter designed for cardiac oxygen saturation. SCIENCE ADVANCES 2021; 7:7/7/eabe0579. [PMID: 33568482 PMCID: PMC7875528 DOI: 10.1126/sciadv.abe0579] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 12/23/2020] [Indexed: 05/02/2023]
Abstract
Accurate, real-time monitoring of intravascular oxygen levels is important in tracking the cardiopulmonary health of patients after cardiothoracic surgery. Existing technologies use intravascular placement of glass fiber-optic catheters that pose risks of blood vessel damage, thrombosis, and infection. In addition, physical tethers to power supply systems and data acquisition hardware limit freedom of movement and add clutter to the intensive care unit. This report introduces a wireless, miniaturized, implantable optoelectronic catheter system incorporating optical components on the probe, encapsulated by soft biocompatible materials, as alternative technology that avoids these disadvantages. The absence of physical tethers and the flexible, biocompatible construction of the probe represent key defining features, resulting in a high-performance, patient-friendly implantable oximeter that can monitor localized tissue oxygenation, heart rate, and respiratory activity with wireless, real-time, continuous operation. In vitro and in vivo testing shows that this platform offers measurement accuracy and precision equivalent to those of existing clinical standards.
Collapse
|
14
|
Stretchable, dynamic covalent polymers for soft, long-lived bioresorbable electronic stimulators designed to facilitate neuromuscular regeneration. Nat Commun 2020; 11:5990. [PMID: 33239608 PMCID: PMC7688647 DOI: 10.1038/s41467-020-19660-6] [Citation(s) in RCA: 88] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 10/19/2020] [Indexed: 11/28/2022] Open
Abstract
Bioresorbable electronic stimulators are of rapidly growing interest as unusual therapeutic platforms, i.e., bioelectronic medicines, for treating disease states, accelerating wound healing processes and eliminating infections. Here, we present advanced materials that support operation in these systems over clinically relevant timeframes, ultimately bioresorbing harmlessly to benign products without residues, to eliminate the need for surgical extraction. Our findings overcome key challenges of bioresorbable electronic devices by realizing lifetimes that match clinical needs. The devices exploit a bioresorbable dynamic covalent polymer that facilitates tight bonding to itself and other surfaces, as a soft, elastic substrate and encapsulation coating for wireless electronic components. We describe the underlying features and chemical design considerations for this polymer, and the biocompatibility of its constituent materials. In devices with optimized, wireless designs, these polymers enable stable, long-lived operation as distal stimulators in a rat model of peripheral nerve injuries, thereby demonstrating the potential of programmable long-term electrical stimulation for maintaining muscle receptivity and enhancing functional recovery.
Collapse
|
15
|
Battery-free, lightweight, injectable microsystem for in vivo wireless pharmacology and optogenetics. Proc Natl Acad Sci U S A 2019; 116:21427-21437. [PMID: 31601737 PMCID: PMC6815115 DOI: 10.1073/pnas.1909850116] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Pharmacology and optogenetics are widely used in neuroscience research to study the central and peripheral nervous systems. While both approaches allow for sophisticated studies of neural circuitry, continued advances are, in part, hampered by technology limitations associated with requirements for physical tethers that connect external equipment to rigid probes inserted into delicate regions of the brain. The results can lead to tissue damage and alterations in behavioral tasks and natural movements, with additional difficulties in use for studies that involve social interactions and/or motions in complex 3-dimensional environments. These disadvantages are particularly pronounced in research that demands combined optogenetic and pharmacological functions in a single experiment. Here, we present a lightweight, wireless, battery-free injectable microsystem that combines soft microfluidic and microscale inorganic light-emitting diode probes for programmable pharmacology and optogenetics, designed to offer the features of drug refillability and adjustable flow rates, together with programmable control over the temporal profiles. The technology has potential for large-scale manufacturing and broad distribution to the neuroscience community, with capabilities in targeting specific neuronal populations in freely moving animals. In addition, the same platform can easily be adapted for a wide range of other types of passive or active electronic functions, including electrical stimulation.
Collapse
|
16
|
Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry. SCIENCE ADVANCES 2019; 5:eaaw0873. [PMID: 30873435 PMCID: PMC6408152 DOI: 10.1126/sciadv.aaw0873] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Accepted: 01/28/2019] [Indexed: 05/18/2023]
Abstract
Monitoring regional tissue oxygenation in animal models and potentially in human subjects can yield insights into the underlying mechanisms of local O2-mediated physiological processes and provide diagnostic and therapeutic guidance for relevant disease states. Existing technologies for tissue oxygenation assessments involve some combination of disadvantages in requirements for physical tethers, anesthetics, and special apparatus, often with confounding effects on the natural behaviors of test subjects. This work introduces an entirely wireless and fully implantable platform incorporating (i) microscale optoelectronics for continuous sensing of local hemoglobin dynamics and (ii) advanced designs in continuous, wireless power delivery and data output for tether-free operation. These features support in vivo, highly localized tissue oximetry at sites of interest, including deep brain regions of mice, on untethered, awake animal models. The results create many opportunities for studying various O2-mediated processes in naturally behaving subjects, with implications in biomedical research and clinical practice.
Collapse
|
17
|
Enzyme-Free Plasmonic Biosensor for Direct Detection of Neurotransmitter Dopamine from Whole Blood. NANO LETTERS 2019; 19:449-454. [PMID: 30525676 DOI: 10.1021/acs.nanolett.8b04253] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Complex biological fluids without pretreatment, separation, or purification impose stringent limitations on the practical deployment of label-free plasmonic biosensors for advanced assays needed in point of care applications. In this work, we present an enzyme-free plasmonic neurotransmitter dopamine biosensor integrated with a microfluidic plasma separator. This integrated device allows the in-line separation of plasma directly from the bloodstream and channels it to the active detection area, where inorganic cerium oxide nanoparticles function as local selective dopamine binding sites through strong surface redox reaction. A thorough understanding and engineering of the nanoparticles is carried out to maximize its dopamine sensitivity and selectivity. We obtain detection of dopamine at 100 fM concentration in simulated body fluid and 1 nM directly from blood without any prior sample preparation. The detection selectivity is found to be at least five-times higher compared to the common interfering species. This demonstration shows the feasibility of the practical implementation of the proposed plasmonic system in detection of variety of biomarkers directly from the complex biological fluids.
Collapse
|
18
|
Cavity-induced hybrid plasmon excitation for perfect infrared absorption. OPTICS LETTERS 2018; 43:6001-6004. [PMID: 30547990 DOI: 10.1364/ol.43.006001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 10/17/2018] [Indexed: 06/09/2023]
Abstract
Photonic microcavity coupling of a subwavelength hole-disk array, a two-element metal/dielectric composite structure with enhanced extraordinary transmission, leads to 100% coupling of incident light to the cavity system and subsequent absorption. This light-funneling process arises from the temporal and spatial coupling of the broadband localized surface plasmon resonance on the coupled hole-disk array and the photonic modes of the optical cavity, which induces spectral narrowing of the perfect absorption of light. A simple nanoimprint lithography-based large-area fabrication process paves the path towards practical implementation of plasmonic cavity-based devices and sensors.
Collapse
|
19
|
Multi-spectral frequency selective mid-infrared microbolometers. OPTICS EXPRESS 2018; 26:32931-32940. [PMID: 30645453 DOI: 10.1364/oe.26.032931] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Accepted: 11/07/2018] [Indexed: 06/09/2023]
Abstract
Frequency selective detection of low energy photons is a scientific challenge using natural materials. A hypothetical surface which functions like a light funnel with very low thermal mass in order to enhance photon collection and suppress background thermal noise is the ideal solution to address both low temperature and frequency selective detection limitations of present detection systems. Here, we present a cavity-coupled quasi-three dimensional plasmonic crystal which induces impedance matching to the free space giving rise to extraordinary transmission through the sub-wavelength aperture array like a "light funnel" in coupling low energy incident photons resulting in frequency selective perfect (~100%) absorption of the incident radiation and zero back reflection. The peak wavelength of absorption of the incident light is almost independent of the angle of incidence and remains within 20% of its maximum (100%) up to θi≤45˚. This perfect absorption results from the incident light-driven localized edge "micro-plasma" currents on the lossy metallic surfaces. The wide-angle light funneling is validated with experimental measurements. Further, a super-lattice based electronic biasing circuit converts the absorbed narrow linewidth (Δλ/λ0< 0.075) photon energy inside the sub-wavelength thick film (< λ/100) to voltage output with high signal to noise ratio close to the theoretical limit. Such artificial plasmonic surfaces enable flexible scaling of light funneling response to any wavelength range by simple dimensional changes paving the path towards room temperature frequency selective low energy photon detection.
Collapse
|
20
|
Covert infrared image encoding through imprinted plasmonic cavities. LIGHT: SCIENCE & APPLICATIONS 2018; 7:93. [PMID: 30479759 PMCID: PMC6249251 DOI: 10.1038/s41377-018-0095-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 11/03/2018] [Accepted: 11/03/2018] [Indexed: 05/25/2023]
Abstract
AbstractFunctional surfaces that can control light across the electromagnetic spectrum are highly desirable. Plasmonic nanostructures can assume this role by exhibiting dimension-tunable resonances that span multiple electromagnetic regimes. However, changing these structural parameters often impacts the higher-order resonances and spectral features in lower-wavelength domains. In this study, we discuss a cavity-coupled plasmonic system with resonances that are tunable across the 3–5 or 8–14 μm infrared bands while retaining near-invariant spectral properties in the visible domain. This result is accomplished by regime-dependent resonance mechanisms and their dependence on independent structural parameters. Through the identification and constraint of key parameters, we demonstrate multispectral data encoding, where images, viewable in the infrared spectral domain, appear as uniform areas of color in the visible domain—effectively hiding the information. Fabricated by large area nanoimprint lithography and compatible with flexible surfaces, the proposed system can produce multifunctional coatings for thermal management, camouflage, and anti-counterfeiting.
Collapse
|
21
|
Superchiral Light Generation on Degenerate Achiral Surfaces. PHYSICAL REVIEW LETTERS 2018; 120:137601. [PMID: 29694216 DOI: 10.1103/physrevlett.120.137601] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Indexed: 05/12/2023]
Abstract
A novel route of superchiral near-field generation is demonstrated based on geometrically achiral systems supporting degenerate and spatially superimposed plasmonic modes. Such systems generate a single-handed chiral near field with simultaneous zero far-field circular dichroism. The phenomenon is theoretically elucidated with a rotating dipole model, which predicts a uniform single-handed chiral near field that flips handedness solely by reversing the handedness of the source. This property allows detection of pure background free molecular chirality through near-field light-matter interaction, which is experimentally demonstrated in the precise identification of both handedness of a chiral molecule on a single substrate with about four orders of magnitude enhancement in detection sensitivity compared to its conventional volumetric counterpart.
Collapse
|
22
|
Hybrid cavity-coupled plasmonic biosensors for low concentration, label-free and selective biomolecular detection. OPTICS EXPRESS 2016; 24:25785-25796. [PMID: 27828513 DOI: 10.1364/oe.24.025785] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Simple optical techniques that can accurately and selectively identify organic and inorganic material in a reproducible manner are of paramount importance in biological sensing applications. In this work, we demonstrate that a nanoimprinted plasmonic pattern with locked-in dimensions supports sharp deterministic hybrid resonances when coupled with an optical cavity suitable for high sensitive surface detection. The surface sensing property of this hybrid system is quantified by precise atomic layer growth of aluminum oxide using the atomic layer deposition technique. The analyte specific sensing ability is demonstrated in the detection of two dissimilar analytes, inorganic amine-coated iron oxide nanoparticles and organic streptavidin protein. Femto to nanomolar detection limits were achieved with the proposed coupled plasmonic system based on the versatile and robust soft nanoimprinting technique, which promises practical low cost biosensors.
Collapse
|
23
|
Multi-spectral infrared spectroscopy for robust plastic identification. APPLIED OPTICS 2015; 54:7396-7405. [PMID: 26368777 DOI: 10.1364/ao.54.007396] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The identification and classification of plastics plays an important role in waste management and recycling processes. Present electrical and optical sorting techniques lack the required resolution for accurate identification in a high throughput manner for a diverse set of plastics commonly found in municipal waste. In this work a multi-spectral infrared spectroscopic technique is employed to construct a unique fingerprint library of 12 plastic resin groups that are commonly encountered in municipal waste. We test the proposed method in a blind plastic identification experiment, which shows excellent unbiased identification accuracy. This simple optical technique in combination with the multi-spectral library will enable high throughput and accurate detection of various plastics from recovered solid waste.
Collapse
|
24
|
Hybrid coupling mechanism in a system supporting high order diffraction, plasmonic, and cavity resonances. PHYSICAL REVIEW LETTERS 2014; 113:263902. [PMID: 25615336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Indexed: 06/04/2023]
Abstract
The interactions between plasmonic and photonic modes of a cavity-coupled plasmonic crystal are studied in diffraction and diffractionless regimes, which lead us to the understanding of coherent interactions between electron plasma, higher order cavity, and diffraction modes. The strong interaction between plasmonic and photonic modes is shown to enhance as well as suppress surface plasmon resonance based on cavity phase relation. Numerical and analytical approaches are developed to accurately explain the physics of the interactions evident in their characteristic dispersion graphs. Further experimental measurements confirm the theoretical predictions.
Collapse
|