1
|
Psychosocial factors, health behaviors and risk of cancer incidence: Testing interaction and effect modification in an individual participant data meta-analysis. Int J Cancer 2024; 154:1745-1759. [PMID: 38289012 DOI: 10.1002/ijc.34852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 11/30/2023] [Accepted: 12/04/2023] [Indexed: 03/14/2024]
Abstract
Depression, anxiety and other psychosocial factors are hypothesized to be involved in cancer development. We examined whether psychosocial factors interact with or modify the effects of health behaviors, such as smoking and alcohol use, in relation to cancer incidence. Two-stage individual participant data meta-analyses were performed based on 22 cohorts of the PSYchosocial factors and CAncer (PSY-CA) study. We examined nine psychosocial factors (depression diagnosis, depression symptoms, anxiety diagnosis, anxiety symptoms, perceived social support, loss events, general distress, neuroticism, relationship status), seven health behaviors/behavior-related factors (smoking, alcohol use, physical activity, body mass index, sedentary behavior, sleep quality, sleep duration) and seven cancer outcomes (overall cancer, smoking-related, alcohol-related, breast, lung, prostate, colorectal). Effects of the psychosocial factor, health behavior and their product term on cancer incidence were estimated using Cox regression. We pooled cohort-specific estimates using multivariate random-effects meta-analyses. Additive and multiplicative interaction/effect modification was examined. This study involved 437,827 participants, 36,961 incident cancer diagnoses, and 4,749,481 person years of follow-up. Out of 744 combinations of psychosocial factors, health behaviors, and cancer outcomes, we found no evidence of interaction. Effect modification was found for some combinations, but there were no clear patterns for any particular factors or outcomes involved. In this first large study to systematically examine potential interaction and effect modification, we found no evidence for psychosocial factors to interact with or modify health behaviors in relation to cancer incidence. The behavioral risk profile for cancer incidence is similar in people with and without psychosocial stress.
Collapse
|
2
|
Treatment and survival of patients diagnosed with high-risk HR+/HER2- breast cancer in the Netherlands: a population-based retrospective cohort study. ESMO Open 2024; 9:103008. [PMID: 38677006 PMCID: PMC11067336 DOI: 10.1016/j.esmoop.2024.103008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 02/21/2024] [Accepted: 03/03/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Several factors may increase the risk of recurrence of patients diagnosed with hormone receptor-positive human epidermal growth factor receptor 2-negative (HR+/HER2-) breast cancer (BC). We aim to determine the proportion of patients with high-risk HR+/HER2- BC within the total HR+/HER2- BC cohort and compare their systemic treatments and survival rates with those of patients with low- and intermediate-risk HR+/HER2- BC and triple-negative (TN) BC. PATIENTS AND METHODS Women diagnosed with nonmetastatic invasive HR+/HER2- BC and TNBC in the Netherlands between 2011 and 2019 were identified from the Netherlands Cancer Registry. Patients with HR+/HER2- BC were categorised according to risk profile, defined by nodal status, tumour size, and histological grade. High-risk HR+/HER2- BC was defined by either four or more positive lymph nodes or one to three positive lymph nodes with a tumour size of ≥5 cm or a histological grade 3 tumour. Overall survival (OS) and relative survival (RS) were calculated using the Kaplan-Meier and Pohar-Perme method. RESULTS In this study of 87 455 patients with HR+/HER2- BC, 44 078 (50%) patients were diagnosed with low risk, 28 452 (33%) with intermediate risk, and 11 285 (13%) with high-risk HR+/HER2- BC. In 3640 (4%) patients, the risk profile could not be defined. Endocrine therapy and chemotherapy were used in 38% and 7% of low-risk, 90% and 47% of intermediate-risk, and 94% and 73% of high-risk patients, respectively. The 10-year OS and RS rates were 84.1% [95% confidence interval (95% CI) 83.5% to 84.7%] and 98.7% (95% CI 97.3% to 99.4%) in low-risk, 75.1% (95% CI 74.2% to 76.0%) and 91.7% (95% CI 89.7% to 93.3%) in intermediate-risk, and 63.4% (95% CI 62.0% to 64.7%) and 72.3% (70.1% to 74.3%) in high-risk patients. The 10-year OS and RS rates of 12 689 patients with TNBC were 69.7% (95% CI 68.6% to 70.8%) and 79.1% (95% CI 77.0% to 80.9%), respectively. CONCLUSION The poor prognosis of patients with high-risk HR+/HER2- BC highlights the need for a better acknowledgement of this subgroup and supports ongoing clinical trials aimed at optimising systemic therapy.
Collapse
|
3
|
Long-term trends in incidence, characteristics and prognosis of screen-detected and interval cancers in women participating in the Dutch breast cancer screening programme. Br J Cancer 2024; 130:1561-1570. [PMID: 38467826 PMCID: PMC11059155 DOI: 10.1038/s41416-024-02633-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 02/18/2024] [Accepted: 02/20/2024] [Indexed: 03/13/2024] Open
Abstract
BACKGROUND No studies are available in which changes over time in characteristics and prognosis of patients with interval breast cancers (ICs) and screen-detected breast cancers (SDCs) have been compared. The aim was to study these trends between 1995 and 2018. METHODS All women with invasive SDCs (N = 4290) and ICs (N = 1352), diagnosed in a southern mammography screening region in the Netherlands, were included and followed until date of death or 31 December 2022. RESULTS The 5-year overall survival rate of women with SDCs increased from 91.4% for those diagnosed in 1995-1999 to 95.0% for those diagnosed in 2013-2018 (P < 0.001), and from 74.8 to 91.6% (P < 0.001) in the same periods for those with ICs. A similar trend was observed for the 10-year survival rates. After adjustment for changes in tumour characteristics, the hazard ratio (HR) for overall survival was 0.47 (95% confidence interval (CI): 0.38-0.59) for women with SDCs diagnosed in the period 2013-2018, compared to the women diagnosed in the period 1995-1999. For the women with ICs this HR was 0.27 (95% CI: 0.19-0.40). CONCLUSION The prognosis of women with ICs has improved rapidly since 1995 and is now almost similar to that of women with SDCs.
Collapse
|
4
|
The mediating role of health behaviors in the association between depression, anxiety and cancer incidence: an individual participant data meta-analysis. Psychol Med 2024:1-14. [PMID: 38680088 DOI: 10.1017/s0033291724000850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
BACKGROUND Although behavioral mechanisms in the association among depression, anxiety, and cancer are plausible, few studies have empirically studied mediation by health behaviors. We aimed to examine the mediating role of several health behaviors in the associations among depression, anxiety, and the incidence of various cancer types (overall, breast, prostate, lung, colorectal, smoking-related, and alcohol-related cancers). METHODS Two-stage individual participant data meta-analyses were performed based on 18 cohorts within the Psychosocial Factors and Cancer Incidence consortium that had a measure of depression or anxiety (N = 319 613, cancer incidence = 25 803). Health behaviors included smoking, physical inactivity, alcohol use, body mass index (BMI), sedentary behavior, and sleep duration and quality. In stage one, path-specific regression estimates were obtained in each cohort. In stage two, cohort-specific estimates were pooled using random-effects multivariate meta-analysis, and natural indirect effects (i.e. mediating effects) were calculated as hazard ratios (HRs). RESULTS Smoking (HRs range 1.04-1.10) and physical inactivity (HRs range 1.01-1.02) significantly mediated the associations among depression, anxiety, and lung cancer. Smoking was also a mediator for smoking-related cancers (HRs range 1.03-1.06). There was mediation by health behaviors, especially smoking, physical inactivity, alcohol use, and a higher BMI, in the associations among depression, anxiety, and overall cancer or other types of cancer, but effects were small (HRs generally below 1.01). CONCLUSIONS Smoking constitutes a mediating pathway linking depression and anxiety to lung cancer and smoking-related cancers. Our findings underline the importance of smoking cessation interventions for persons with depression or anxiety.
Collapse
|
5
|
Predictors of re-attendance at biennial screening mammography following a false positive referral: A study among women in the south of the Netherlands. Breast 2024; 74:103702. [PMID: 38447293 PMCID: PMC10924204 DOI: 10.1016/j.breast.2024.103702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 02/15/2024] [Accepted: 02/26/2024] [Indexed: 03/08/2024] Open
Abstract
AIM A false positive (FP) referral after screening mammography may influence a woman's likelihood to re-attend the screening program. The impact of having a FP result in the first or subsequent screening round on re-attendance after a FP result was investigated. In addition, we aimed to study differences in re-attendance rates between women who underwent non-invasive and invasive additional examinations as part of the diagnostic work-up following a FP referral. METHODS A consecutive series of 13,597 women with a FP referral following biennial screening mammography in the south of the Netherlands between 2009 and 2019 was included. RESULTS The screening re-attendance rate was 81.2% after a FP referral, and 91.3% when also including women who had clinical mammographic follow-up. Women who received a FP referral in the first screening round were less likely to re-attend the screening programme in the following three years, compared to those with a FP test in any subsequent round (odds ratio (OR): 0.59, 95%-confidence interval (CI): 0.51-0.69). Women with a FP referral who underwent invasive examinations after referral were less likely to re-attend the screening programme than those who only received additional imaging (OR, 0.48; 95% CI 0.36-0.64). CONCLUSION Women with a FP referral are less likely to re-attend the screening programme if this referral occurs at their first screening round or when they undergo invasive diagnostic workup. Hospitals and screening organizations should prioritize informing women about the importance of re-attending the programme following a FP referral.
Collapse
|
6
|
Prognostic value of histopathologic traits independent of stromal tumor-infiltrating lymphocyte levels in chemotherapy-naïve patients with triple-negative breast cancer. ESMO Open 2024; 9:102923. [PMID: 38452438 PMCID: PMC10937239 DOI: 10.1016/j.esmoop.2024.102923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 01/09/2024] [Accepted: 02/04/2024] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND In the absence of prognostic biomarkers, most patients with early-stage triple-negative breast cancer (eTNBC) are treated with combination chemotherapy. The identification of biomarkers to select patients for whom treatment de-escalation or escalation could be considered remains an unmet need. We evaluated the prognostic value of histopathologic traits in a unique cohort of young, (neo)adjuvant chemotherapy-naïve patients with early-stage (stage I or II), node-negative TNBC and long-term follow-up, in relation to stromal tumor-infiltrating lymphocytes (sTILs) for which the prognostic value was recently reported. MATERIALS AND METHODS We studied all 485 patients with node-negative eTNBC from the population-based PARADIGM cohort which selected women aged <40 years diagnosed between 1989 and 2000. None of the patients had received (neo)adjuvant chemotherapy according to standard practice at the time. Associations between histopathologic traits and breast cancer-specific survival (BCSS) were analyzed with Cox proportional hazard models. RESULTS With a median follow-up of 20.0 years, an independent prognostic value for BCSS was observed for lymphovascular invasion (LVI) [adjusted (adj.) hazard ratio (HR) 2.35, 95% confidence interval (CI) 1.49-3.69], fibrotic focus (adj. HR 1.61, 95% CI 1.09-2.37) and sTILs (per 10% increment adj. HR 0.75, 95% CI 0.69-0.82). In the sTILs <30% subgroup, the presence of LVI resulted in a higher cumulative incidence of breast cancer death (at 20 years, 58%; 95% CI 41% to 72%) compared with when LVI was absent (at 20 years, 32%; 95% CI 26% to 39%). In the ≥75% sTILs subgroup, the presence of LVI might be associated with poor survival (HR 11.45, 95% CI 0.71-182.36, two deaths). We confirm the lack of prognostic value of androgen receptor expression and human epidermal growth factor receptor 2 -low status. CONCLUSIONS sTILs, LVI and fibrotic focus provide independent prognostic information in young women with node-negative eTNBC. Our results are of importance for the selection of patients for de-escalation and escalation trials.
Collapse
|
7
|
Long-term outcomes of young, node-negative, chemotherapy-naïve, triple-negative breast cancer patients according to BRCA1 status. BMC Med 2024; 22:9. [PMID: 38191387 PMCID: PMC10775514 DOI: 10.1186/s12916-023-03233-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 12/15/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Due to the abundant usage of chemotherapy in young triple-negative breast cancer (TNBC) patients, the unbiased prognostic value of BRCA1-related biomarkers in this population remains unclear. In addition, whether BRCA1-related biomarkers modify the well-established prognostic value of stromal tumor-infiltrating lymphocytes (sTILs) is unknown. This study aimed to compare the outcomes of young, node-negative, chemotherapy-naïve TNBC patients according to BRCA1 status, taking sTILs into account. METHODS We included 485 Dutch women diagnosed with node-negative TNBC under age 40 between 1989 and 2000. During this period, these women were considered low-risk and did not receive chemotherapy. BRCA1 status, including pathogenic germline BRCA1 mutation (gBRCA1m), somatic BRCA1 mutation (sBRCA1m), and tumor BRCA1 promoter methylation (BRCA1-PM), was assessed using DNA from formalin-fixed paraffin-embedded tissue. sTILs were assessed according to the international guideline. Patients' outcomes were compared using Cox regression and competing risk models. RESULTS Among the 399 patients with BRCA1 status, 26.3% had a gBRCA1m, 5.3% had a sBRCA1m, 36.6% had tumor BRCA1-PM, and 31.8% had BRCA1-non-altered tumors. Compared to BRCA1-non-alteration, gBRCA1m was associated with worse overall survival (OS) from the fourth year after diagnosis (adjusted HR, 2.11; 95% CI, 1.18-3.75), and this association attenuated after adjustment for second primary tumors. Every 10% sTIL increment was associated with 16% higher OS (adjusted HR, 0.84; 95% CI, 0.78-0.90) in gBRCA1m, sBRCA1m, or BRCA1-non-altered patients and 31% higher OS in tumor BRCA1-PM patients. Among the 66 patients with tumor BRCA1-PM and ≥ 50% sTILs, we observed excellent 15-year OS (97.0%; 95% CI, 92.9-100%). Conversely, among the 61 patients with gBRCA1m and < 50% sTILs, we observed poor 15-year OS (50.8%; 95% CI, 39.7-65.0%). Furthermore, gBRCA1m was associated with higher (adjusted subdistribution HR, 4.04; 95% CI, 2.29-7.13) and tumor BRCA1-PM with lower (adjusted subdistribution HR, 0.42; 95% CI, 0.19-0.95) incidence of second primary tumors, compared to BRCA1-non-alteration. CONCLUSIONS Although both gBRCA1m and tumor BRCA1-PM alter BRCA1 gene transcription, they are associated with different outcomes in young, node-negative, chemotherapy-naïve TNBC patients. By combining sTILs and BRCA1 status for risk classification, we were able to identify potential subgroups in this population to intensify and optimize adjuvant treatment.
Collapse
|
8
|
External validation and clinical utility assessment of PREDICT breast cancer prognostic model in young, systemic treatment-naïve women with node-negative breast cancer. Eur J Cancer 2023; 195:113401. [PMID: 37925965 DOI: 10.1016/j.ejca.2023.113401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/19/2023] [Accepted: 10/19/2023] [Indexed: 11/07/2023]
Abstract
BACKGROUND The validity of the PREDICT breast cancer prognostic model is unclear for young patients without adjuvant systemic treatment. This study aimed to validate PREDICT and assess its clinical utility in young women with node-negative breast cancer who did not receive systemic treatment. METHODS We selected all women from the Netherlands Cancer Registry who were diagnosed with node-negative breast cancer under age 40 between 1989 and 2000, a period when adjuvant systemic treatment was not standard practice for women with node-negative disease. We evaluated the calibration and discrimination of PREDICT using the observed/expected (O/E) mortality ratio, and the area under the receiver operating characteristic curve (AUC), respectively. Additionally, we compared the potential clinical utility of PREDICT for selectively administering chemotherapy to the chemotherapy-to-all strategy using decision curve analysis at predefined thresholds. RESULTS A total of 2264 women with a median age at diagnosis of 36 years were included. Of them, 71.2% had estrogen receptor (ER)-positive tumors and 44.0% had grade 3 tumors. Median tumor size was 16 mm. PREDICT v2.2 underestimated 10-year all-cause mortality by 33% in all women (O/E ratio:1.33, 95%CI:1.22-1.43). Model discrimination was moderate overall (AUC10-year:0.65, 95%CI:0.62-0.68), and poor for women with ER-negative tumors (AUC10-year:0.56, 95%CI:0.51-0.62). Compared to the chemotherapy-to-all strategy, PREDICT only showed a slightly higher net benefit in women with ER-positive tumors, but not in women with ER-negative tumors. CONCLUSIONS PREDICT yields unreliable predictions for young women with node-negative breast cancer. Further model updates are needed before PREDICT can be routinely used in this patient subset.
Collapse
|
9
|
Trends in the pre-operative diagnosis and surgical management of axillary lymph node metastases in women with screen-detected breast cancer. Breast 2023; 72:103593. [PMID: 37890215 PMCID: PMC10624574 DOI: 10.1016/j.breast.2023.103593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 10/14/2023] [Accepted: 10/19/2023] [Indexed: 10/29/2023] Open
Abstract
AIM The aim of the current study was to investigate time-trends in pre-operative diagnosis and surgical treatment of axillary lymph node metastases in breast cancers detected at screening mammography. METHODS We included all women who underwent screening mammography in the South of the Netherlands between 2005 and 2020. During a follow-up period of at least two years, data on clinical radiological examinations, biopsy procedures and surgical interventions were obtained. The 15 years of inclusion were divided into five cohorts of three years each. RESULTS Of the 4049 women with invasive breast cancer, 22.1 % (896/4049) had axillary lymph node metastasis at pathology (ALN+). Percutaneous axillary biopsy was performed in 39.6 % (355/896) of these women, with the proportions of fine needle aspiration biopsy (FNAB) decreasing from 97.6 % (40/41) in 2005-2007 to 41.6 % (37/89) in 2017-2019 and core needle biopsy (CNB) rising from 2.4 % (1/41) in 2005-2007 to 58.4 % (52/89) in 2017-2019 (P < 0.001). Sensitivity of FNAB and CNB was comparable (77.4 % (188/243, 95%CI = 71%-82 %) versus 82.4 % (103/125), 95%CI = 74%-88 %) (P = 0.26). Pre-operative confirmation of ALN + by percutaneous biopsy ranged from 27.3 % (56/205) in 2011-2013 to 39.0 % (80/205) in 2017-2019, with no significant trend changes over time (P = 0.103). The proportion of ALN + women who underwent axillary lymph node dissection (ALND) decreased from 96.0 % (97/101) in 2005-2007 to 16.6 % (34/205) in 2017-2019 (P < 0.001). CONCLUSION Pre-operative confirmation of axillary lymph node metastasis by ultrasound-guided biopsy did not rise despite the increased use of CNB at the expense of less invasive FNAB. A significant reduction in ALND was observed through the years.
Collapse
|
10
|
Depression, anxiety, and the risk of cancer: An individual participant data meta-analysis. Cancer 2023; 129:3287-3299. [PMID: 37545248 DOI: 10.1002/cncr.34853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/16/2023] [Accepted: 04/07/2023] [Indexed: 08/08/2023]
Abstract
BACKGROUND Depression and anxiety have long been hypothesized to be related to an increased cancer risk. Despite the great amount of research that has been conducted, findings are inconclusive. To provide a stronger basis for addressing the associations between depression, anxiety, and the incidence of various cancer types (overall, breast, lung, prostate, colorectal, alcohol-related, and smoking-related cancers), individual participant data (IPD) meta-analyses were performed within the Psychosocial Factors and Cancer Incidence (PSY-CA) consortium. METHODS The PSY-CA consortium includes data from 18 cohorts with measures of depression or anxiety (up to N = 319,613; cancer incidences, 25,803; person-years of follow-up, 3,254,714). Both symptoms and a diagnosis of depression and anxiety were examined as predictors of future cancer risk. Two-stage IPD meta-analyses were run, first by using Cox regression models in each cohort (stage 1), and then by aggregating the results in random-effects meta-analyses (stage 2). RESULTS No associations were found between depression or anxiety and overall, breast, prostate, colorectal, and alcohol-related cancers. Depression and anxiety (symptoms and diagnoses) were associated with the incidence of lung cancer and smoking-related cancers (hazard ratios [HRs], 1.06-1.60). However, these associations were substantially attenuated when additionally adjusting for known risk factors including smoking, alcohol use, and body mass index (HRs, 1.04-1.23). CONCLUSIONS Depression and anxiety are not related to increased risk for most cancer outcomes, except for lung and smoking-related cancers. This study shows that key covariates are likely to explain the relationship between depression, anxiety, and lung and smoking-related cancers. PREREGISTRATION NUMBER: https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=157677.
Collapse
|
11
|
Clinical value of contralateral breast cancers detected by pre-operative MRI in patients diagnosed with DCIS: a population-based cohort study. Eur Radiol 2023; 33:2209-2217. [PMID: 36180645 PMCID: PMC9935702 DOI: 10.1007/s00330-022-09115-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 07/01/2022] [Accepted: 08/16/2022] [Indexed: 01/25/2023]
Abstract
OBJECTIVES For patients with ductal carcinoma in situ (DCIS), data about the impact of breast MRI at primary diagnosis on the incidence and characteristics of contralateral breast cancers are scarce. METHODS We selected all 8486 women diagnosed with primary DCIS in the Netherlands in 2011-2015 from the Netherlands Cancer Registry. The synchronous and metachronous detection of contralateral DCIS (cDCIS) and contralateral invasive breast cancer (cIBC) was assessed for patients who received an MRI upon diagnosis (MRI group) and for an age-matched control group without MRI. RESULTS Nineteen percent of patients received an MRI, of which 0.8% was diagnosed with synchronous cDCIS and 1.3% with synchronous cIBC not found by mammography. The 5-year cumulative incidence of synchronous plus metachronous cDCIS was higher for the MRI versus age-matched control group (2.0% versus 0.9%, p = 0.02) and similar for cIBC (3.5% versus 2.3%, p = 0.17). The increased incidence of cDCIS was observed in patients aged < 50 years (sHR = 4.22, 95% CI: 1.19-14.99), but not in patients aged 50-74 years (sHR = 0.89, 95% CI: 0.41-1.93). CONCLUSIONS MRI at primary DCIS diagnosis detected additional synchronous cDCIS and cIBC, and was associated with a higher rate of metachronous cDCIS without decreasing the rate of metachronous cIBC. This finding was most evident in younger patients. KEY POINTS • Magnetic resonance imaging at primary diagnosis of ductal carcinoma in situ detected an additional synchronous breast lesion in 2.1% of patients. • In patients aged younger than 50 years, the use of pre-operative MRI was associated with a fourfold increase in the incidence of a second contralateral DCIS without decreasing the incidence of metachronous invasive breast cancers up to 5 years after diagnosis. • In patients aged over 50 years, the use of pre-operative MRI did not result in a difference in the incidence of a second contralateral DCIS or metachronous invasive breast cancer.
Collapse
|
12
|
5-year adherence to adjuvant endocrine treatment in Dutch women with early stage breast cancer: A population-based database study (2006-2016). Breast Dis 2023; 42:331-339. [PMID: 37927248 DOI: 10.3233/bd-230024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
BACKGROUND Hormonal receptor (HR) positive breast tumors are common. Adjuvant hormonal therapy (AHT) with tamoxifen or Aromatase Inhibitors (AIs) is beneficial depending on the stage of the tumor. Despite the fact that AHT has been shown to improve survival and recurrence, Dutch adherence rates, which were mostly dependent on Tamoxifen prescriptions until 2006, plummeted from 80% after one year to 50% after five years. Nonadherence with AHT reduces its effectiveness. This research presents more recent adherence statistics (from 2006 to 2016), on a larger sample (7,996 vs 1,451), as well as factors that influence AHT adherence. In addition to tamoxifen data, AIs are now included. OBJECTIVE As low use of adjuvant endocrine therapy is a potentially important and modifiable risk factor for poor outcome, it is important to monitor the rate as an indicator of women's burden of disease and the direction of adherence trends. METHODS The Netherlands Cancer Registry (NCR) was used to find women with early-stage breast cancer who started AHT within a year of surgery and were linked to the PHARMO Database Network (n = 8,679). The Kaplan-Meier approach was used to measure AHT adherence five years after treatment was started, with a 60-day gap between refills as our primary outcome. Furthermore, the Medication Possession Rate (MPR) was determined using a cutoff of ≥80%. Analysis was performed on influential factors of adherence. RESULTS The proportion of persistent women declined over time to reach 46.6% at the end of the fifth year and 53.3% of the women had a MPR ≥80% during the fifth year. Older and being diagnosed in 2006-2010 were associated with AHT adherence. CONCLUSION Dutch 5-year AHT adherence appears to remain poor. Improving AHT adherence in HR+ breast cancer survivors is a critical medical need.
Collapse
|
13
|
Failure of stereotactic core needle biopsy in women recalled for suspicious calcifications at screening mammography: frequency, causes, and final outcome in a multi-institutional, observational follow-up study. Eur Radiol 2022; 32:7420-7429. [PMID: 35486173 DOI: 10.1007/s00330-022-08806-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 03/20/2022] [Accepted: 04/08/2022] [Indexed: 01/03/2023]
Abstract
OBJECTIVES We determined the failure rate of stereotactic core needle biopsy (SCNB) and its causes and final outcome in women recalled for calcifications at screening mammography. METHODS We included a consecutive series of 624,039 screens obtained in a Dutch screening region between January 2009 and July 2019. Radiology reports and pathology results were obtained of all recalled women during 2-year follow-up. RESULTS A total of 3495 women (19.6% of 17,809 recalls) were recalled for suspicious calcifications. SCNB was indicated in 2818 women, of whom 12 had incomplete follow-up and another 12 women refused biopsy. DCIS or invasive cancer was diagnosed in 880 of the remaining 2794 women (31.5%). SCNB failed in 62 women (2.2%, 36/2794). These failures were mainly due to a too posterior (n = 30) or too superficial location (n = 17) of the calcifications or calcifications too faint for biopsy (n = 13). Of these 62 women, 10 underwent surgical biopsy, yielding one DCIS (intermediate grade) and two invasive cancers (one intermediate grade and one high grade) and another two women were diagnosed with DCIS (both high grade) at follow-up. Thus, the malignancy rate after SCNB failure was 8.1% (5/62). Calcifications were depicted neither at SCNB specimen radiography nor at pathology in 16 women after (repeated) SCNB (0.6%, 31/2732). None of them proved to have breast cancer at 2-year follow-up. CONCLUSIONS The failure rate of SCNB for suspicious calcifications is low but close surveillance is warranted, as breast cancer may be present in up to 8% of these women. KEY POINTS • The failure rate of stereotactic core needle biopsy (SCNB) for calcifications recalled at screening mammography was 2.2%. • Failures were mainly due to calcifications that could not be reached by SCNB or calcifications too faint for biopsy. • The management after failed SCNB was various. At least, close surveillance with a low threshold for surgical biopsy is recommended as breast cancer may be present in up to 8% of women with SCNB failure.
Collapse
|
14
|
Risk of metachronous contralateral breast cancer in patients with primary invasive lobular breast cancer: Results from a nationwide cohort. Cancer Med 2022; 12:3123-3133. [PMID: 36127572 PMCID: PMC9939202 DOI: 10.1002/cam4.5235] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/12/2022] [Accepted: 08/31/2022] [Indexed: 11/11/2022] Open
Abstract
Lobular primary breast cancer (PBC) histology has been proposed as a risk factor for contralateral breast cancer (CBC), but results have been inconsistent. We investigated CBC risk and the impact of systemic therapy in lobular versus ductal PBC. Further, CBC characteristics following these histologic subtypes were explored. We selected 74,373 women diagnosed between 2003 and 2010 with stage I-III invasive PBC from the nationwide Netherlands Cancer Registry. We assessed absolute risk of CBC taking into account competing risks among those with lobular (n = 8903), lobular mixed with other types (n = 3512), versus ductal (n = 62,230) histology. Hazard ratios (HR) for CBC were estimated in a cause-specific Cox model, adjusting for age at PBC diagnosis, radiotherapy, chemotherapy and/or endocrine therapy. Multivariable HRs for CBC were 1.18 (95% CI: 1.04-1.33) for lobular and 1.37 (95% CI: 1.16-1.63) for lobular mixed versus ductal PBC. Ten-year cumulative CBC incidences in patients with lobular, lobular mixed versus ductal PBC were 3.2%, 3.6% versus 2.8% when treated with systemic therapy and 6.6%, 7.7% versus 5.6% in patients without systemic therapy, respectively. Metachronous CBCs were diagnosed in a less favourable stage in 19%, 26% and 23% and less favourable differentiation grade in 22%, 33% and 27% than the PBCs of patients with lobular, lobular mixed and ductal PBC, respectively. In conclusion, lobular and lobular mixed PBC histology are associated with modestly increased CBC risk. Personalised CBC risk assessment needs to consider PBC histology, including systemic treatment administration. The impact on prognosis of CBCs with unfavourable characteristics warrants further evaluation.
Collapse
|
15
|
De-escalation of radiotherapy after primary chemotherapy in cT1-2N1 breast cancer (RAPCHEM; BOOG 2010-03): 5-year follow-up results of a Dutch, prospective, registry study. Lancet Oncol 2022; 23:1201-1210. [PMID: 35952707 DOI: 10.1016/s1470-2045(22)00482-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 07/08/2022] [Accepted: 07/12/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Primary chemotherapy in breast cancer poses a dilemma with regard to adjuvant locoregional radiotherapy, as guidelines for locoregional radiotherapy were originally based on pathology results of primary surgery. We aimed to evaluate the oncological safety of de-escalated locoregional radiotherapy in patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to a predefined, consensus-based study guideline. METHODS In this prospective registry study (RAPCHEM, BOOG 2010-03), patients referred to one of 17 participating radiation oncology centres in the Netherlands between Jan 1, 2011, and Jan 1, 2015, with cT1-2N1 breast cancer (one to three suspicious nodes on imaging before primary chemotherapy, of which at least one had been pathologically confirmed), and who were treated with primary chemotherapy and surgery of the breast and axilla were included in the study. The study guideline comprised three risk groups for locoregional recurrence, with corresponding locoregional radiotherapy recommendations: no chest wall radiotherapy and no regional radiotherapy in the low-risk group, only local radiotherapy in the intermediate-risk group, and locoregional radiotherapy in the high-risk group. Radiotherapy consisted of a biologically equivalent dose of 25 fractions of 2 Gy, with or without a boost. During the study period, the generally applied radiotherapy technique in the Netherlands was forward-planned or inverse-planned intensity modulated radiotherapy. 5-year follow-up was assessed, taking into account adherence to the study guideline, with locoregional recurrence rate as primary endpoint. We hypothesised that 5-year locoregional recurrence rate would be less than 4% (upper-limit 95% CI 7·8%). This study was registered at ClinicalTrials.gov, NCT01279304, and is completed. FINDINGS 838 patients were eligible for 5-year follow-up analyses: 291 in the low-risk group, 370 in the intermediate-risk group, and 177 in the high-risk group. The 5-year locoregional recurrence rate in all patients was 2·2% (95% CI 1·4-3·4). The 5-year locoregional recurrence rate was 2·1% (0·9-4·3) in the low-risk group, 2·2% (1·0-4·1) in the intermediate-risk group, and 2·3% (0·8-5·5) in the high-risk group. If the study guideline was followed, the locoregional recurrence rate was 2·3% (0·8-5·3) for the low-risk group, 1·0% (0·2-3·4) for the intermediate-risk group, and 1·4% (0·3-4·5) for the high-risk group. INTERPRETATION In this study, the 5-year locoregional recurrence rate was less than 4%, which supports our hypothesis that it is oncologically safe to de-escalate locoregional radiotherapy based on locoregional recurrence risk, in selected patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to this predefined, consensus-based study guideline. FUNDING Dutch Cancer Society. TRANSLATION For the Dutch translation of the abstract see Supplementary Materials section.
Collapse
|
16
|
Prognostic Value of Stromal Tumor-Infiltrating Lymphocytes in Young, Node-Negative, Triple-Negative Breast Cancer Patients Who Did Not Receive (neo)Adjuvant Systemic Therapy. J Clin Oncol 2022; 40:2361-2374. [PMID: 35353548 PMCID: PMC9287283 DOI: 10.1200/jco.21.01536] [Citation(s) in RCA: 45] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
PURPOSE Triple-negative breast cancer (TNBC) is considered aggressive, and therefore, virtually all young patients with TNBC receive (neo)adjuvant chemotherapy. Increased stromal tumor-infiltrating lymphocytes (sTILs) have been associated with a favorable prognosis in TNBC. However, whether this association holds for patients who are node-negative (N0), young (< 40 years), and chemotherapy-naïve, and thus can be used for chemotherapy de-escalation strategies, is unknown. METHODS We selected all patients with N0 TNBC diagnosed between 1989 and 2000 from a Dutch population–based registry. Patients were age < 40 years at diagnosis and had not received (neo)adjuvant systemic therapy, as was standard practice at the time. Formalin-fixed paraffin-embedded blocks were retrieved (PALGA: Dutch Pathology Registry), and a pathology review including sTILs was performed. Patients were categorized according to sTILs (< 30%, 30%-75%, and ≥ 75%). Multivariable Cox regression was performed for overall survival, with or without sTILs as a covariate. Cumulative incidence of distant metastasis or death was analyzed in a competing risk model, with second primary tumors as competing risk. RESULTS sTILs were scored for 441 patients. High sTILs (≥ 75%; 21%) translated into an excellent prognosis with a 15-year cumulative incidence of a distant metastasis or death of only 2.1% (95% CI, 0 to 5.0), whereas low sTILs (< 30%; 52%) had an unfavorable prognosis with a 15-year cumulative incidence of a distant metastasis or death of 38.4% (32.1 to 44.6). In addition, every 10% increment of sTILs decreased the risk of death by 19% (adjusted hazard ratio: 0.81; 95% CI, 0.76 to 0.87), which are an independent predictor adding prognostic information to standard clinicopathologic variables (χ2 = 46.7, P < .001). CONCLUSION Chemotherapy-naïve, young patients with N0 TNBC with high sTILs (≥ 75%) have an excellent long-term prognosis. Therefore, sTILs should be considered for prospective clinical trials investigating (neo)adjuvant chemotherapy de-escalation strategies. Young cancer patients with TNBC and high sTILs have an excellent outcome, even without systemic treatment![]()
Collapse
|
17
|
Breast magnetic resonance imaging as a problem solving tool in women recalled at biennial screening mammography: A population-based study in the Netherlands. Breast 2021; 60:279-286. [PMID: 34823112 PMCID: PMC8628012 DOI: 10.1016/j.breast.2021.11.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 11/18/2021] [Accepted: 11/19/2021] [Indexed: 11/27/2022] Open
Abstract
Purpose Problem solving magnetic resonance imaging (MRI) is used to exclude malignancy in women with equivocal findings on conventional imaging. However, recommendations on its use for women recalled after screening are lacking. This study evaluates the impact of problem solving MRI on diagnostic workup among women recalled from the Dutch screening program, as well as time trends and inter-hospital variation in its use. Methods Women who were recalled at screening mammography in the South of the Netherlands (2008–2017) were included. Two-year follow-up data were collected. Diagnostic-workup and accuracy of problem solving MRI were evaluated and time trends and inter-hospital variation in its use were examined. Results In the study period 16,175 women were recalled, of whom 906 underwent problem solving MRI. Almost half of the women (45.4%) who underwent problem solving MRI were referred back to the screening program without further workup. The sensitivity, specificity, and positive and negative predictive values of problem solving MRI were 98.2%, 70.0%, 31.1%, and 99.6%, respectively. The percentage of recalled women receiving problem solving MRI fluctuated over time (4.7%–7.2%) and significantly varied among hospitals (2.2%–7.0%). Conclusion The use of problem solving MRI may exclude malignancy in recalled women. The use of problem solving MRI varied over time and among hospitals, which indicates the need for guidelines on problem solving MRI. Problem solving MRI did correctly refer back women to the screening program. The sensitivity and specificity of problem solving MRI were 98.2% and 70.0%. Positive and negative predictive values of problem solving MRI were 31.1% and 99.6%. By excluding malignancy, problem solving MRI may reduce invasive diagnostic workup.
Collapse
|
18
|
Nationwide registry study on trends in localization techniques and reoperation rates in non-palpable ductal carcinoma in situ and invasive breast cancer. Br J Surg 2021; 109:53-60. [PMID: 34642736 DOI: 10.1093/bjs/znab339] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 09/01/2021] [Indexed: 12/22/2022]
Abstract
BACKGROUND There is a transition from wire-guided localization (WGL) of non-palpable breast cancer to other localization techniques. Multiple prospective studies have sought to establish superior clinical outcomes for radioactive-seed localization (RSL), but consistent and congruent evidence is missing. METHODS In this study, female patients with breast cancer operated with breast-conserving surgery after tumour localization of a non-palpable breast cancer or ductal carcinoma in situ (DCIS) were included. The cohort was identified from the nationwide Netherlands Breast Cancer Audit conducted between 2013 and 2018. Trends in localization techniques were analysed. Univariable and multivariable analyses were performed to assess the association between the localization technique and the probability of a reoperation. RESULTS A total of 28 370 patients were included in the study cohort. The use of RSL increased from 15.7 to 61.1 per cent during the study years, while WGL decreased from 75.4 to 31.6 per cent. The localization technique used (RSL versus WGL) was not significantly associated with the odds of a reoperation, regardless of whether the lesion was DCIS (odds ratio 0.96 (95 per cent c.i. 0.89 to 1.03; P = 0.281)) or invasive breast cancer (OR 1.02 (95 per cent c.i. 0.96 to 1.10; P = 0.518)). CONCLUSION RSL is rapidly replacing WGL as the preoperative localization technique in breast surgery. This large nationwide registry study found no association between the type of localization technique and the odds of having a reoperation, thus confirming the results of previous prospective cohort studies.
Collapse
|
19
|
Psychosocial factors and cancer incidence (PSY-CA): Protocol for individual participant data meta-analyses. Brain Behav 2021; 11:e2340. [PMID: 34473425 PMCID: PMC8553309 DOI: 10.1002/brb3.2340] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 08/12/2021] [Indexed: 01/12/2023] Open
Abstract
OBJECTIVES Psychosocial factors have been hypothesized to increase the risk of cancer. This study aims (1) to test whether psychosocial factors (depression, anxiety, recent loss events, subjective social support, relationship status, general distress, and neuroticism) are associated with the incidence of any cancer (any, breast, lung, prostate, colorectal, smoking-related, and alcohol-related); (2) to test the interaction between psychosocial factors and factors related to cancer risk (smoking, alcohol use, weight, physical activity, sedentary behavior, sleep, age, sex, education, hormone replacement therapy, and menopausal status) with regard to the incidence of cancer; and (3) to test the mediating role of health behaviors (smoking, alcohol use, weight, physical activity, sedentary behavior, and sleep) in the relationship between psychosocial factors and the incidence of cancer. METHODS The psychosocial factors and cancer incidence (PSY-CA) consortium was established involving experts in the field of (psycho-)oncology, methodology, and epidemiology. Using data collected in 18 cohorts (N = 617,355), a preplanned two-stage individual participant data (IPD) meta-analysis is proposed. Standardized analyses will be conducted on harmonized datasets for each cohort (stage 1), and meta-analyses will be performed on the risk estimates (stage 2). CONCLUSION PSY-CA aims to elucidate the relationship between psychosocial factors and cancer risk by addressing several shortcomings of prior meta-analyses.
Collapse
|
20
|
Rate and predictors of nodal pathological complete response following neoadjuvant endocrine treatment in clinically biopsy-proven node-positive breast cancer patients. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2021; 47:1928-1933. [PMID: 34030918 DOI: 10.1016/j.ejso.2021.04.041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 04/10/2021] [Accepted: 04/28/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Data on effectiveness and optimal use of neoadjuvant endocrine therapy (NET) in clinically biopsy-proven node-positive breast cancer is lacking. This study examined the incidence of axillary pathological complete response (pCR) on NET in clinically biopsy-proven node-positive breast cancer patients. Secondary, patient and tumour characteristics, as well as the optimal duration of NET in relation to the occurrence of axillary pCR were investigated. MATERIAL AND METHODS Patients diagnosed with primary hormone receptor positive, HER2 negative breast cancer between 2014 and 2019, with at least one positive axillary lymph node (pathologically proven), treated with NET were selected from the Netherlands Cancer Registry. The incidence of axillary pCR in combination with patient, tumour and treatment characteristics was analysed. RESULTS In a population of 561 patients, an axillary pCR of 7.3% on NET was observed. Median length of treatment was 8.1 months in the patients without vs. 8.8 months in those with axillary pCR, with no statistically significant difference. A p-value <0.30 was found for age, histologic type, clinical tumour status, hormone receptor status and the type of NET in univariable analysis. After multivariable logistic regression analyses, none of these variables were independently associated with the likelihood of an axillary pCR. CONCLUSION The rate of axillary pCR after NET in HR + HER2-clinically biopsy-proven node-positive breast cancer patients is low. Factors independently associated with the likelihood of an axillary pCR could not be identified. More research is warranted regarding optimizing the duration of NET and the prognostic value of residual disease in the axilla after NET.
Collapse
|
21
|
ASO Visual Abstract: The Impact of Preoperative Breast MRI on Surgical Margin Status in Breast Cancer Patients Recalled at Biennial Screening Mammography: An Observational Cohort Study. Ann Surg Oncol 2021. [PMID: 33987760 DOI: 10.1245/s10434-021-10001-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
22
|
ASO Author Reflections: Impact of Preoperative MRI on Patients With Screen-Detected Invasive Breast Cancer Undergoing Breast-Conserving Surgery. Ann Surg Oncol 2021; 28:5939-5940. [PMID: 33843026 PMCID: PMC8460541 DOI: 10.1245/s10434-021-09936-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 03/17/2021] [Indexed: 11/18/2022]
|
23
|
The Impact of Preoperative Breast MRI on Surgical Margin Status in Breast Cancer Patients Recalled at Biennial Screening Mammography: An Observational Cohort Study. Ann Surg Oncol 2021; 28:5929-5938. [PMID: 33796997 PMCID: PMC8460561 DOI: 10.1245/s10434-021-09868-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 03/02/2021] [Indexed: 01/10/2023]
Abstract
Background This study aimed to examine the association between preoperative magnetic resonance imaging (MRI) and surgical margin involvement, as well as to determine the factors associated with positive resection margins in screen-detected breast cancer patients undergoing breast-conserving surgery (BCS). Methods Breast cancer patients eligible for BCS and diagnosed after biennial screening mammography in the south of The Netherlands (2008–2017) were retrospectively included. Missing values were imputed and multivariable regression analyses were performed to analyze whether preoperative MRI was related to margin involvement after BCS, as well as to examine what factors were associated with positive resection margins, defined as more than focally (>4 mm) involved. Results Overall, 2483 patients with invasive breast cancer were enrolled, of whom 123 (5.0%) had more than focally involved resection margins. In multivariable regression analyses, preoperative MRI was associated with a reduced risk of positive resection margins after BCS (adjusted odds ratio [OR] 0.56, 95% confidence interval [CI] 0.33–0.96). Lobular histology (adjusted OR 2.86, 95% CI 1.68–4.87), large tumor size (per millimeter increase, adjusted OR 1.05, 95% CI 1.03–1.07), high (>75%) mammographic density (adjusted OR 3.61, 95% CI 1.07–12.12), and the presence of microcalcifications (adjusted OR 4.45, 95% CI 2.69–7.37) and architectural distortions (adjusted OR 1.85, 95% CI 1.01–3.40) were independently associated with positive resection margins after BCS. Conclusions Preoperative MRI was associated with lower risk of positive resection margins in patients with invasive breast cancer eligible for BCS using multivariable analysis. Furthermore, specific mammographic characteristics and tumor characteristics were independently associated with positive resection margins after BCS.
Collapse
|
24
|
Repeat breast-conserving treatment of ipsilateral breast cancer recurrence: a nationwide survey amongst breast surgeons and radiation oncologists in the Netherlands. Breast Cancer Res Treat 2021; 187:499-514. [PMID: 33713244 PMCID: PMC8189996 DOI: 10.1007/s10549-021-06154-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 02/20/2021] [Indexed: 12/02/2022]
Abstract
Background In line with the paradigm to minimize surgical morbidity in patients with primary breast cancer, there is increasing evidence for the safety of a repeat breast-conserving treatment (BCT) of an ipsilateral breast tumour recurrence (IBTR) in selected patients. The conditions for the feasibility of a repeat BCT vary widely in literature. In clinical practice, many physicians have ongoing concerns about the oncological safety and possible toxicity of repeat BCT. Aim To investigate the attitude of Dutch breast surgeons and radiation oncologists towards repeat BCT and to report on their experiences with, objections against and perceived requirements to consider a repeat BCT in case of IBTR. Patients and methods An online survey consisting of a maximum of 26 open and multiple-choice questions about repeat BCT for IBTR was distributed amongst Dutch breast surgeons and radiation oncologists. Results Forty-nine surgeons representing 49% of Dutch hospitals and 20 radiation oncologists representing 70% of Dutch radiation oncology centres responded. A repeat BCT was considered feasible in selected cases by 28.7% of breast surgeons and 55% of radiation oncologists. The most important factors to consider a repeat BCT for both groups were the patient’s preference to preserve the breast and surgical feasibility of a second lumpectomy. Arguments against a repeat BCT were based on the perceived unacceptable toxicity and cosmesis of a second course of radiotherapy. The technique of preference for re-irradiation would be partial breast irradiation (PBI) according to all radiation oncologists. Differentiating between new primary tumours (NPT) and true recurrences (TR) was reported to be done by 57.1% of breast surgeons and 60% of radiation oncologists. The most important reason to differentiate between NPT and TR was to establish prognosis and to consider whether a repeat BCT would be feasible. Conclusion An increasing number of Dutch breast cancer specialists is considering a repeat BCT feasible in selected cases, at the patient’s preference and with partial breast re-irradiation.
Collapse
|
25
|
Trends in delayed breast cancer diagnosis after recall at screening mammography. Eur J Radiol 2021; 136:109517. [PMID: 33421886 DOI: 10.1016/j.ejrad.2020.109517] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 12/19/2020] [Accepted: 12/28/2020] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To determine the extent and characteristics of delay in breast cancer diagnosis in women recalled at screening mammography. METHODS We included a consecutive series of 817,656 screens of women who received biennial screening mammography in a Dutch breast cancer screening region between 1997 and 2016. During at least 3.5 years follow-up, radiological reports and biopsy reports were collected of all recalled women. The inclusion period was divided into four cohorts of four years each. We determined the number of screen-detected cancers and their characteristics, and assessed the proportion of recalled women who experienced a diagnostic delay of at least 4 months in breast cancer confirmation. RESULTS The proportion of recalled women who experienced diagnostic delay decreased from 7.5 % in 1997-2001 (47/623) to 3.0 % in 2012-2016 (67/2223, P < 0.001). The proportion of women with a delay of at least two years increased from 27.7 % (13/47) in 1997-2001 to 75.7 % (53/70) in 2012-2016 (P < 0.001). Cancers with a diagnostic delay > 2 years were more frequently invasive (P = 0.009) than cancers with a diagnostic delay of 4-24 months. The most frequent cause of diagnostic delays was incorrect radiological classifications by clinical radiologists (55.2 % overall) after recall. CONCLUSIONS The proportion of recalled women with a delayed breast cancer diagnosis has more than halved during two decades of screening mammography. Delays in breast cancer diagnosis are characterized by longer delay intervals, although the proportion of these delays among all screen-detected cancers has not increased. Preventing longer delays in breast cancer confirmation may help improve breast cancer survival.
Collapse
|
26
|
Comprehensive trends in incidence, treatment, survival and mortality of first primary invasive breast cancer stratified by age, stage and receptor subtype in the Netherlands between 1989 and 2017. Int J Cancer 2020; 148:2289-2303. [PMID: 33252836 PMCID: PMC8048677 DOI: 10.1002/ijc.33417] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/27/2020] [Accepted: 11/11/2020] [Indexed: 01/06/2023]
Abstract
Our study aimed to provide a comprehensive overview of trends in incidence, survival, mortality and treatment of first primary invasive breast cancer (BC), according to age, stage and receptor subtype in the Netherlands between 1989 and 2017. Data from all women diagnosed with first primary stage I to IV BC (N = 320 249) were obtained from the Netherlands Cancer Registry. BC mortality and general population data were retrieved from Statistics Netherlands. Age-standardised incidence and mortality rates were calculated with annual percentage change (APC) and average annual percentage change (AAPC) statistics. The relative survival (RS) was used as estimator for disease-specific survival. The BC incidence for all BC patients combined significantly increased until 2013 from 126 to 158 per 100 000 person-years, after which a declining trend was observed. Surgery became less extensive, but (neo-)adjuvant systemic treatments and their combinations were given more frequently. The RS improved for all age groups and for most stages and receptor subtypes, but remained stable for all subtypes since 2012 to 2013 and since 2000 to 2009 for Stage IV BC at 15 years of follow-up. Overall, the 5- and 10-year RS increased from 76.8% (95% confidence interval [CI]: 76.1, 77.4) and 55.9% (95% CI: 54.7, 57.1) in 1989 to 1999 to 91.0% (95% CI: 90.5, 91.5) and 82.9% (95% CI: 82.2, 83.5), respectively, in 2010 to 2016. BC mortality improved regardless of age and overall decreased from 57 to 35 per 100 000 person-years between 1989 and 2017. In conclusion, the BC incidence in the Netherlands has steadily increased since 1989, but the latest trends show promising declines. Survival improved markedly for most patients and the mortality decreased regardless of age.
Collapse
|
27
|
The effect of breast MRI on disease-free and overall survival in breast cancer patients: a retrospective population-based study. Breast Cancer Res Treat 2020; 184:951-963. [PMID: 32930928 PMCID: PMC7655574 DOI: 10.1007/s10549-020-05906-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 08/31/2020] [Indexed: 01/19/2023]
Abstract
Purpose To evaluate the effect of breast MRI on overall survival (OS) and disease-free survival (DFS) of patients with invasive breast cancer in the Netherlands. Methods We selected all women from the Netherlands Cancer Registry diagnosed with invasive breast cancer (a) between 2011 and 2013 for the OS-cohort and (b) in the first quarter of 2012 for the DFS-cohort. The study population was subdivided into an MRI and non-MRI group. In addition, subgroups were created according to breast cancer subtype: invasive carcinoma of no special type (NST) versus invasive lobular carcinoma (ILC). OS and DFS were compared between the MRI and non-MRI group using the Kaplan–Meier method and the log-rank test. Cox proportional hazard regression analysis was performed to estimate hazard ratios (HR) with a 95% confidence interval (CI). To account for missing data, multiple imputation was performed. Results Of the 31,756 patients included in the OS-cohort (70% non-MRI and 30% MRI), 27,752 (87%) were diagnosed with invasive carcinoma NST and 4004 (13%) with ILC. Of the 2464 patients included in the DFS-cohort (72% non-MRI and 28% MRI), 2161 (88%) were diagnosed with invasive carcinoma NST and 303 (12%) with ILC. The distribution of breast MRI use was significantly lower over different age categories, from 49.0% aged < 50 to 16.5% aged > 70. Multivariable Cox regression showed that breast MRI was not significantly associated with OS overall (HR 0.91, 95%-CI 0.74–1.11, p = 0.35), nor in the different histological subtypes. Multivariable Cox regression analysis showed that breast MRI was also not significantly associated with DFS (HR 1.16, 95%-CI 0.81–1.67), nor in the different histological subtypes. Conclusion Use of breast MRI was not significantly associated with an improved OS or DFS in patients treated with primary surgery. Electronic supplementary material The online version of this article (10.1007/s10549-020-05906-w) contains supplementary material, which is available to authorized users.
Collapse
|
28
|
Local staging of ipsilateral breast tumor recurrence: mammography, ultrasound, or MRI? Breast Cancer Res Treat 2020; 184:385-395. [PMID: 32770456 PMCID: PMC7599170 DOI: 10.1007/s10549-020-05850-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/30/2020] [Indexed: 01/09/2023]
Abstract
BACKGROUND Despite increasingly effective curative breast-conserving treatment (BCT) regimens for primary breast cancer, patients remain at risk for an ipsilateral breast tumor recurrence (IBTR). With increasing interest for repeat BCT in selected patients with IBTR, a reliable assessment of the size of IBTR is important for surgical planning. AIM The primary aim of this study is to establish the performance in size estimation of XMG, US, and breast MRI in patients with IBTR. The secondary aim is to compare the detection of multifocality and contralateral lesions between XMG and MRI. PATIENTS AND METHODS The sizes of IBTR on mammography (XMG), ultrasound (US), and magnetic resonance imaging (MRI) in 159 patients were compared to the sizes at final histopathology. The accuracy of the size estimates was addressed using Pearson's coefficient and Bland-Altman plots. Secondary outcomes were the detection of multifocality and contralateral lesions between XMG and MRI. RESULTS Both XMG and US significantly underestimated the tumor size by 3.5 and 4.8 mm, respectively, while MRI provided accurate tumor size estimation with a mean underestimation of 1.1 mm. The sensitivity for the detection of multifocality was significantly higher for MRI compared to XMG (25.5% vs. 5.5%). A contralateral malignancy was found in 4.4% of patients, and in 1.9%, it was detected by MRI only. CONCLUSION The addition of breast MRI to XMG and US in the preoperative workup of IBTR allows for more accurate size estimation. MRI provides a higher sensitivity for the detection of multifocality compared to XMG.
Collapse
|
29
|
Frequency and diagnostic outcome of bilateral recall at screening mammography. Int J Cancer 2020; 148:48-56. [PMID: 32621785 PMCID: PMC7689830 DOI: 10.1002/ijc.33187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 05/25/2020] [Accepted: 06/04/2020] [Indexed: 12/20/2022]
Abstract
Our study was performed to determine the frequency of recall for bilateral breast lesions at screening mammography and compare its outcome with respect to unilateral recall. We included 329 132 screening mammograms (34 889 initial screens and 294 243 subsequent screens) from a Dutch screening mammography program between January 2013 and January 2018. During a 2‐year follow‐up, we collected radiological data, pathology reports and surgical reports of all recalled women. At bilateral recall, the lesion with the highest Breast Imaging Reporting and Data System score was used as the index lesion when comparing screening mammography characteristics at bilateral vs unilateral recall. A total of 9806 women were recalled at screening (recall rate, 3.0%). Bilateral recall comprised 2.8% (271/9806) of all recalls. Biopsy was more frequently performed after bilateral recall than unilateral recall (54.6% [148/271] vs 44.1% [4201/9535], P < .001), yielding a lower positive predictive value (PPV) of biopsy after bilateral recall (42.6% vs 51.7%, P = .029). The PPV of recall was comparable for both groups (23.2% [63/271] vs 22.8% [2173/9535], P = .85). Invasive cancers after bilateral recall were larger than those diagnosed after unilateral recall (P = .02), but histological subtype, histologic grading, receptor status and proportions of lymph node positive cancers were comparable. Bilateral recall infrequently occurs at screening mammography. Biopsy is more frequently performed following bilateral recall, but the PPV of recall is similar for unilateral and bilateral recall. Invasive cancers of both groups show comparable pathological features except of a larger tumor size after bilateral recall. What's new? Data on bilateral breast cancer in a screened population is sparse, and information on bilateral recall is lacking. Based on more than 329,000 screening mammograms, our study shows that bilateral recall occurs infrequently at screening mammography, and that the majority of these recalls are false positives. Invasive cancer has comparable pathological features in bilateral and unilateral breast cancer patients, except larger tumour size after bilateral recall. Altogether, the results highlight the need for screening radiologists to pay vigorous attention to the contralateral breast after detecting a screening mammographic abnormality in order to facilitate a timely diagnosis of bilateral breast cancer.
Collapse
|
30
|
Delayed breast cancer diagnosis after repeated recall at biennial screening mammography: an observational follow-up study from the Netherlands. Br J Cancer 2020; 123:325-332. [PMID: 32390006 PMCID: PMC7374543 DOI: 10.1038/s41416-020-0870-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 04/03/2020] [Accepted: 04/15/2020] [Indexed: 02/08/2023] Open
Abstract
Background Delay in detection of breast cancer may worsen tumour characteristics, with progression of tumour size and a higher risk of metastatic lymph nodes. The purpose of this study was to investigate delayed breast cancer diagnosis after repeated recall for the same mammographic abnormality at screening. Methods This was a retrospective study performed in two cohorts of women enrolled in a mammography screening programme in the Netherlands. All women aged 50−75 who underwent biennial screening mammography either between January 1, 1997 and December 31, 2006 (cohort 1) or between January 1, 2007 and December 31, 2016 (cohort 2) were included. Results The cohorts showed no difference in proportions of women with delayed breast cancer diagnosis of at least 2 years (2.2% versus 2.8%, P = 0.29). Most delays were caused by incorrect BI-RADS classifications after recall (74.2%). An increase in mean tumour size was seen when comparing sizes at initial false-negative recall and at diagnosis of breast cancer (P < 0.001). Conclusions The proportion of women with a long delay in breast cancer confirmation following repeated recall at screening mammography has not decreased during 20 years of screening. These delays lead to larger tumour size at detection and may negatively influence prognosis.
Collapse
|
31
|
Multifocality in ipsilateral breast tumor recurrence - A study in ablative specimens. Eur J Surg Oncol 2020; 46:1471-1476. [PMID: 32402507 DOI: 10.1016/j.ejso.2020.04.035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 02/24/2020] [Accepted: 04/17/2020] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND The incidence and clinical significance of multifocality in ipsilateral breast tumor recurrence (IBTR) after breast-conserving therapy (BCT) are unclear. With growing interest in repeat BCT, this information has become of importance. This study aimed to gain insight in the incidence of multifocality in IBTR, to identify patient- and tumor-related predicting factors and to investigate the prognostic significance of multifocality. METHODS Two hundred and fifteen patients were included in this analysis. All had an IBTR after BCT and were treated by salvage mastectomy and appropriate adjuvant therapy. Predictive tumor- and patient-related factors for multifocality in IBTR were identified using X2 test and univariate logistic regression analyses. Prognostic outcomes were calculated using Kaplan Meier analysis and compared using the log rank test. RESULTS Multifocality was present in 50 (22.9%) of IBTR mastectomy specimens. Axillary positivity in IBTR was significantly associated with multifocality in IBTR. Chest wall re-recurrences occurred more often after multifocal IBTR (14% versus 7% after unifocal IBTR, p = 0.120). Regional re-recurrences did not differ significantly between unifocal and multifocal IBTR (8% vs. 6%, p = 0.773). Distant metastasis after salvage surgery occurred more frequently after multifocal IBTR (15% vs. 24%, p = 0.122). Overall survival was 132 months after unifocal IBTR and 112 months after multifocal IBTR (p = 0.197). CONCLUSION The prevalence of multifocality in IBTR is higher than in primary breast cancer. Axillary positivity in IBTR was associated with a multifocal IBTR. Chest wall re-recurrences and distant metastasis were, although not statistically significant, more prevalent after multifocal IBTR.
Collapse
|
32
|
Additional Breast Cancer Detection at Digital Screening Mammography through Quality Assurance Sessions between Technologists and Radiologists. Radiology 2020; 294:509-517. [DOI: 10.1148/radiol.2019191388] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
33
|
[Experiences with axillary reverse mapping]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2020; 164:D4222. [PMID: 32267646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Axillary reverse mapping (ARM) is a technique by which the lymphatic drainage system of the upper extremities is mapped, so that the lymph channels and glands can be preserved during axillary lymph node dissection (ALND). This can lead to less postoperative morbidity, such as lymphoedema. A randomised multicentre study showed that there are statistically significantly fewer post-operative symptoms if the lymph channels and glands of the upper extremities are spared with this technique. Despite the declining indication for an ALND, ARM can have added value for the patients who do have to undergo ALND.
Collapse
|
34
|
Radiotherapy after primary CHEMotherapy (RAPCHEM): Practice variation in a Dutch registration study (BOOG 2010-03). Radiother Oncol 2020; 145:201-208. [PMID: 32058873 DOI: 10.1016/j.radonc.2020.01.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 01/13/2020] [Accepted: 01/18/2020] [Indexed: 12/20/2022]
Abstract
BACKGROUND We conducted a prospective cohort study in the Netherlands (RAPCHEM: NCT01279304, BOOG 2010-03) in breast cancer (BC) patients treated with primary systemic therapy (PST), followed by surgery and post-operative radiation therapy (RT) according to a predefined consensus-based study-guideline (SG). The aim of the current analysis is to evaluate adherence to the SG. METHODS From January 2011 to January 2015, patients with cT1-2N1 BC treated in 17 Dutch RT Centres were included. Patients with four or more suspicious nodes at imaging were excluded. SG recommended whole breast RT for patients treated with breast conserving therapy. SG on loco(-regional) RT were defined for three risk groups based on the ypN status: (1) ypN0 (low-risk): RT breast and no RT after mastectomy; (2) ypN1 (intermediate-risk): RT breast or chest wall; (3) ypN2 (high-risk): RT breast or chest wall, including regional lymph nodes. RESULTS We included 848 patients: 292 in the low-risk group; 374 in the intermediate-risk group; 182 in the high-risk group. Overall, 64% of the patients was treated according to the SG; 11% received less RT than the predefined target volumes and 25% received more extensive RT than according to the SG. The largest variation was seen in the intermediate risk group, where only 54% was treated according to the SG. CONCLUSION Substantial deviation from the SG for post-operative RT was observed after PST, especially in patients with an intermediate-risk. Future analyses will evaluate outcome of these patients in relation to risk factors and the actual RT given.
Collapse
|
35
|
Recall and Outcome of Screen-detected Microcalcifications during 2 Decades of Mammography Screening in the Netherlands National Breast Screening Program. Radiology 2020; 294:528-537. [PMID: 31990268 DOI: 10.1148/radiol.2020191266] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Trends in the detection of suspicious microcalcifications at mammography screening and the yield of these lesions after recall are unknown. Purpose To determine trends in recall and outcome of screen-detected microcalcifications during 20 years of mammography screening. Materials and Methods The authors performed a retrospective analysis of a consecutive series of 817 656 screening examinations (January 1997 to January 2017) in a national breast screening program. In 2009-2010 (transition period), screen-film mammography (SFM) was gradually replaced by full-field digital mammography (FFDM). The recalls of suspicious microcalcifications from all radiology reports and pathologic outcome of recalled women with 2-year follow-up were analyzed. Screening outcome in the era of SFM (1997-2008), the transition period (2009-2010), and the era of FFDM (2011-2016) were compared. Trends over time and variations between the SFM and FFDM periods were expressed by using proportions with 95% confidence intervals (CIs). In cases where the analysis based on the CI confirmed clear periods (eg, before and after introduction of FFDM), pre- and postchange outcomes were compared by using χ2 tests. Results A total of 18 592 women (median age, 59 years; interquartile range, 14 years) were recalled at mammography screening, 3556 of whom had suspicious microcalcifications. The recall rate for microcalcifications increased from 0.1% in 1997-1998 to 0.5% in 2015-2016 (P < .001). This was temporally associated with the change from SFM to FFDM. The recalls yielding ductal carcinoma in situ (DCIS) increased from 0.3 per 1000 screening examinations with SFM to 1.1 per 1000 screening examinations with FFDM (P < .001), resulting in a decrease in the positive predictive value for recall for suspicious microcalcifications from 51% to 33% (P < .001). More than half of all DCIS lesions were high grade (52.6%; 393 of 747). The distribution of DCIS grades was stable during the 20-year screening period (P = .36). Conclusion The recall rate for suspicious microcalcifications at mammographic screening increased during the past 2 decades, whereas the ductal carcinoma in situ detection rate increased less rapidly, resulting in a lower positive predictive value for recall. © RSNA, 2020.
Collapse
|
36
|
Prognostic impact of repeat sentinel lymph node biopsy in patients with ipsilateral breast tumour recurrence. Br J Surg 2019; 106:574-585. [PMID: 30908615 DOI: 10.1002/bjs.11097] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 08/27/2018] [Accepted: 11/20/2018] [Indexed: 11/08/2022]
Abstract
BACKGROUND Ipsilateral breast tumour recurrence (IBTR) has an unfavourable prognosis, with a significant subsequent risk of distant recurrence. Repeat sentinel lymph node biopsy (rSLNB) has recently been demonstrated to be technically feasible and useful in tailoring adjuvant treatment plans in patients with IBTR. The prognostic impact of rSLNB in patients with IBTR remains unclear. This study analysed the risk of distant recurrence after IBTR, and evaluated the prognostic impact of rSLNB and other patient and tumour characteristics on distant recurrence-free survival. METHODS Data were obtained from the SNARB (Sentinel Node and Recurrent Breast Cancer) study. Cox proportional hazards analyses were performed to assess the prognostic effect of tumour, patient and treatment factors on distant recurrence-free survival. RESULTS Of the 515 included patients, 230 (44·7 per cent) had a tumour-negative rSLNB and 46 (8·9 per cent) a tumour-positive rSLNB. In 239 patients (46·4 per cent) the rSLNB procedure was unsuccessful. After a median follow-up of 5·1 years, 115 patients (22·3 per cent) had developed a recurrence. The overall 5-year distant recurrence-free survival rate was 84·2 (95 per cent c.i. 80·7 to 87·7) per cent. An interval of less than 2 years between primary breast cancer treatment and ipsilateral recurrence (P = 0·018), triple-negative IBTR (P = 0·045) and absence of adjuvant chemotherapy after IBTR (P = 0·010) were independently associated with poor distant recurrence-free survival. The association between the outcome of rSLNB and distant recurrence-free survival was not statistically significant (P = 0·682). CONCLUSION The outcome of rSLNB is not an important prognostic factor for distant recurrence, and its value as a staging tool in patients with IBTR seems disputable.
Collapse
|
37
|
Population-based study of the effect of preoperative breast MRI on the surgical management of ductal carcinoma in situ. Br J Surg 2019; 106:1488-1494. [PMID: 31386197 PMCID: PMC6790575 DOI: 10.1002/bjs.11299] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 02/22/2019] [Accepted: 06/02/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND Determinants of the use of breast MRI in patients with ductal carcinoma in situ (DCIS) in the Netherlands were studied, and whether using MRI influenced the rates of positive resection margins and mastectomies. METHODS All women aged less than 75 years, and diagnosed with DCIS between 2011 and 2015, were identified from the Netherlands Cancer Registry. Multivariable logistic regression analyses were performed, adjusting for incidence year, age, hospital type, DCIS grade and multifocality. RESULTS Breast MRI was performed in 2382 of 10 415 DCIS cases (22·9 per cent). In multivariable analysis, patients aged less than 50 years, those with high- or intermediate-grade DCIS and patients with multifocal disease were significantly more likely to have preoperative MRI. Patients undergoing MRI were more likely to have a mastectomy, either as first surgical treatment or following breast-conserving surgery (BCS) in the event of positive margins (odds ratio (OR) 2·11, 95 per cent c.i. 1·91 to 2·33). The risk of positive surgical margins after BCS was similar for those with versus without MRI. The secondary mastectomy rate after BCS was higher in patients who had MRI, especially in women aged less than 50 years (OR 1·94, 1·31 to 2·89). All findings were similar for low- and intermediate/high-grade DCIS. CONCLUSION Adding MRI to conventional breast imaging did not improve surgical outcome in patients diagnosed with primary DCIS. The likelihood of undergoing a mastectomy was twice as high in the MRI group, and no reduction in the risk of margin involvement was observed after BCS.
Collapse
|
38
|
A patient- and assessor-blinded randomized controlled trial of axillary reverse mapping (ARM) in patients with early breast cancer. EUROPEAN JOURNAL OF SURGICAL ONCOLOGY 2019; 46:59-64. [PMID: 31402072 DOI: 10.1016/j.ejso.2019.08.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/01/2019] [Accepted: 08/04/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND Axillary lymph node dissection (ALND) in breast cancer patients is infamous for its accompanying morbidity. Selective preservation of upper extremity lymphatic drainage and accompanying lymph nodes crossing the axillary basin - currently resected during a standard ALND - has been proposed as a valuable surgical refinement. METHODS Peroperative Axillary Reversed Mapping (ARM) was used for selective preservation of upper extremity lymphatic drainage. A multicentre patient- and assessor-blinded randomized study was performed in clinical node negative, sentinel node positive early breast cancer patients. Patients were randomized to undergo either standard-ALND or ARM-ALND. Primary outcome was the presence of surgery-related lymphedema at six, 12 and 24 months post-operatively. Secondary outcomes included patient reported and objective signs and symptoms of lymphedema, pain, paraesthesia, numbness, loss of shoulder mobility, quality of life and axillary recurrence risk. RESULTS No significant differences were found between both groups using the water displacement method with respect to measured lymphedema. ARM-ALND resulted in less reported complaints of lymphedema at six, 12 and 24 months postoperatively (p < 0.05). No axillary recurrence was found in both groups. CONCLUSIONS In contrast to results of volumetric measurement, patient reported outcomes support selective sparing of the upper extremity lymphatic drainage using ARM as valuable surgical refinement in case of ALND in clinically node negative, sentinel node positive early breast cancer. If completion ALND in clinically node negative, sentinel node positive early breast cancer is considered, selective sparing of upper extremity axillary lymphatics by implementing ARM should be carried out in order to reduce morbidity.
Collapse
|
39
|
Utility of diagnostic breast excision biopsies during two decades of screening mammography. Breast 2019; 46:157-162. [DOI: 10.1016/j.breast.2019.05.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 05/28/2019] [Accepted: 05/31/2019] [Indexed: 01/19/2023] Open
|
40
|
Predicting the extent of nodal involvement for node positive breast cancer patients: Development and validation of a novel tool. J Surg Oncol 2019; 120:578-586. [PMID: 31338839 PMCID: PMC6771524 DOI: 10.1002/jso.25644] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 07/10/2019] [Indexed: 12/22/2022]
Abstract
Background This study aimed to develop an easy to use prediction model to predict the risk of having a total of 1 to 2, ≥3, or ≥4 positive axillary lymph nodes (LNs), for patients with sentinel lymph node (SLN) positive breast cancer. Methods Data of 911 SLN positive breast cancer patients were used for model development. The model was validated externally in an independent population of 180 patients with SLN positive breast cancer. Results Final pathology after ALND showed additional positive LN for 259 (28%) of the patients. A total of 726 (81%) out of 911 patients had a total of 1 to 2 positive nodes, whereas 175 (19%) had ≥3 positive LNs. The model included three predictors: the tumor size (in mm), the presence of a negative SLN, and the size of the SLN metastases (in mm). At external validation, the model showed a good discriminative ability (area under the curve = 0.82; 95% confidence interval = 0.74‐0.90) and good calibration over the full range of predicted probabilities. Conclusion This new and validated model predicts the extent of nodal involvement in node‐positive breast cancer and will be useful for counseling patients regarding their personalized axillary treatment.
Collapse
|
41
|
Trends in frequency and outcome of high-risk breast lesions at core needle biopsy in women recalled at biennial screening mammography, a multiinstitutional study. Int J Cancer 2019; 145:2720-2727. [PMID: 31001821 PMCID: PMC6766874 DOI: 10.1002/ijc.32353] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 03/21/2019] [Accepted: 04/11/2019] [Indexed: 11/18/2022]
Abstract
Between January 1, 2011, and December 31, 2016, we studied the incidence, management and outcome of high‐risk breast lesions in a consecutive series of 376,519 screens of women who received biennial screening mammography. During the 6‐year period covered by the study, the proportion of women who underwent core needle biopsy (CNB) after recall remained fairly stable, ranging from 39.2% to 48.1% (mean: 44.2%, 5,212/11,783), whereas the proportion of high‐risk lesions at CNB (i.e., flat epithelial atypia, atypical ductal hyperplasia, lobular carcinoma in situ and papillary lesions) gradually increased from 3.2% (25/775) in 2011 to 9.5% (86/901) in 2016 (p < 0.001). The mean proportion of high‐risk lesions at CNB that were subsequently treated with diagnostic surgical excision was 51.4% (169/329) and varied between 41.0% and 64.3% through the years, but the excision rate for high‐risk lesions per 1,000 screens and per 100 recalls increased from 0.25 (2011) to 0.70 (2016; p < 0.001) and from 0.81 (2011) to 2.50 (2016; p < 0.001), respectively. The proportion of all diagnostic surgical excisions showing in situ or invasive breast cancer was 29.0% (49/169) and varied from 22.2% (8/36) in 2014 to 38.5% (5/13) in 2011. In conclusion, the proportion of high‐risk lesions at CNB tripled in a 6‐year period, with a concomitant increased excision rate for these lesions. As the proportion of surgical excisions showing in situ or invasive breast cancer did not increase, a rising number of screened women underwent invasive surgical excision with benign outcome. What's new? Screening mammography aims to catch breast cancer early to reduce associated morbidity and mortality. Women with suspect findings at mammography frequently are recalled for further testing with core needle biopsy (CNB). In this investigation, the proportion of high‐risk lesions detected at CNB was found to have tripled among women in the Netherlands who underwent mammographic screening between 2011 and 2016. This increase was accompanied by an increase in lesion excision rates. Of excised lesions, little more than 14% proved to be malignant at two‐year follow‐up. The remainder of lesions exhibited benign pathology, suggesting that many women underwent potentially unnecessary surgery.
Collapse
|
42
|
Screening for distant metastases in patients with ipsilateral breast tumor recurrence: the impact of different imaging modalities on distant recurrence-free interval. Breast Cancer Res Treat 2019; 175:419-428. [PMID: 30955183 PMCID: PMC6533220 DOI: 10.1007/s10549-019-05205-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 03/15/2019] [Indexed: 02/07/2023]
Abstract
Purpose In patients with ipsilateral breast tumor recurrence (IBTR), the detection of distant disease determines whether the intention of the treatment is curative or palliative. Therefore, adequate preoperative staging is imperative for optimal treatment planning. The aim of this study is to evaluate the impact of conventional imaging techniques, including chest X-ray and/or CT thorax-(abdomen), liver ultrasonography(US), and skeletal scintigraphy, on the distant recurrence-free interval (DRFI) in patients with IBTR, and to compare conventional imaging with 18F-FDG PET-CT or no imaging at all. Methods This study was exclusively based on the information available at time of diagnoses of IBTR. To adjust for differences in baseline characteristics between the three imaging groups, a propensity score (PS) weighted method was used. Results Of the 495 patients included in the study, 229 (46.3%) were staged with conventional imaging, 89 patients (19.8%) were staged with 18F-FDG PET-CT, and in 168 of the patients (33.9%) no imaging was used (N = 168). After a follow-up of approximately 5 years, 14.5% of all patients developed a distant recurrence as first event after IBTR. After adjusting for the PS weights, the Cox regression analyses showed that the different staging methods had no significant impact on the DRFI. Conclusions This study showed a wide variation in the use of imaging modalities for staging IBTR patients in the Netherlands. After using PS weighting, no statistically significant impact of the different imaging modalities on DRFI was shown. Based on these results, it is not possible to recommend staging for distant metastases using 18F-FDG PET-CT over conventional imaging techniques. Electronic supplementary material The online version of this article (10.1007/s10549-019-05205-z) contains supplementary material, which is available to authorized users.
Collapse
|
43
|
Low Risk of Development of a Regional Recurrence After an Unsuccessful Repeat Sentinel Lymph Node Biopsy in Patients with Ipsilateral Breast Tumor Recurrence. Ann Surg Oncol 2019; 26:2417-2427. [PMID: 30850903 DOI: 10.1245/s10434-019-07272-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Indexed: 11/18/2022]
Abstract
BACKGROUND Unlike sentinel lymph node biopsy (SLNB) in the primary setting, the repeat SLNB (rSLNB) in patients with ipsilateral breast tumor recurrence (IBTR) is challenging, because it is difficult to visualize and/or harvest a sentinel lymph node in every patient. Regional treatments options and safety in terms of regional disease control after such an unsuccessful rSLNB remain unclear. This study assesses factors associated with the performance of axillary lymph node dissection (ALND) after unsuccessful rSLNB and evaluates the occurrence of regional recurrences. METHODS Data were obtained from the Sentinel Node and Recurrent Breast Cancer (SNARB) study. In 239 patients, the rSLNB was unsuccessful, of whom 60 patients underwent ipsilateral ALND. RESULTS A shorter time interval between primary treatment and IBTR, and a primary negative SLNB were significantly associated with a higher probability to be treated with ALND after unsuccessful rSLNB (P < 0.001). The 5-year regional-recurrence rate was 0.0% in the ALND group compared with 3.7% in the group treated without ALND (P = 0.113). Of the 179 patients treated without ALND, after a median follow-up of 5.1 years (range 0.3-13.2), 7 (3.9%) developed a regional recurrence as first event after unsuccessful rSLNB. None of the seven recurrences occurred in the ipsilateral axilla. Univariable analysis showed no factors associated with regional recurrence as first event after unsuccessful rSLNB (P > 0.05). CONCLUSIONS The present study demonstrates that the risk of regional recurrence in patients with an IBTR and an unsuccessful rSLNB is negligible, irrespective of the use of ALND. This suggests that there is no need for additional treatment of the axilla after an unsuccessful rSLNB.
Collapse
|
44
|
Abstract P4-09-07: Higher risk of metachronous contralateral breast cancer in patients with invasive lobular breast cancer. Cancer Res 2019. [DOI: 10.1158/1538-7445.sabcs18-p4-09-07] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Background: Risk of metachronous contralateral breast cancer (CBC) is an important health issue in primary breast cancer (PBC) survivors. Individualized CBC risk prediction can help identify patients at high or low risk who may or may not benefit from additional surveillance and treatment. For lobular PBC, inconsistent results have been reported on an association with increased risk of CBC. We investigated CBC risk in lobular versus ductal PBC using a large nationwide dataset and taking into account age at PBC and (neo-)adjuvant systemic therapy effects.
Patients and Methods: We selected women diagnosed between 2003 and 2010 with early invasive lobular, lobular mixed with other types, or ductal PBC from the Netherlands Cancer Registry. Categorical and continuous characteristics between the 3 groups were compared using the chi-square statistics and the Kruskal-Wallis test, respectively. Competing risk analyses were applied to determine CBC incidence. Multivariable subdistribution hazard ratios (SHRs) were adjusted for primary tumor stage, age at PBC diagnosis, radiotherapy, (neo-)adjuvant chemotherapy and endocrine therapy.
Results: We selected 74,373 women aged >18 years with lobular (n=8,903), lobular mixed (n=3,512), and ductal (n=62,230) PBC. Women with lobular PBC were older at diagnosis than women with lobular mixed or ductal PBC (61 vs. 58 vs. 58 years, respectively), more often had ER-positive PBC (95.7% vs. 94.1% vs. 79.6%) and were more often systemically treated with only endocrine therapy (30.7% vs. 24.9% vs. 19.7%), while less often treated with only chemotherapy (4.2% vs. 5.3% vs. 15.4%).
Ten-year cumulative CBC incidences in women with lobular, lobular mixed or ductal PBC were 3.2%, 3.6% and 2.8% when treated with systemic therapy (chemotherapy and/or endocrine therapy) and 6.6%, 7.7% and 5.6% without systemic therapy, respectively. Multivariable SHRs were 1.19 (95% CI: 1.05-1.34) for lobular and 1.39 (95% CI: 1.17-1.65) for lobular mixed versus ductal PBC; for women <50 years, risk differences were larger: 1.60 (95% CI: 1.26-2.05) and 1.43 (95% CI: 1.00-2.06), respectively.
Conclusion: Lobular histology and lobular mixed histology are independent risk factors for CBC development, and should be considered as prognostic factors when refining CBC risk prediction models.
Citation Format: Akdeniz D, Kramer I, van Deurzen CH, Schaapveld M, Westenend PJ, Voogd AC, Jager A, Steyerberg EW, Sleijfer S, Schmidt MK, Hooning MJ. Higher risk of metachronous contralateral breast cancer in patients with invasive lobular breast cancer [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr P4-09-07.
Collapse
|
45
|
Repeat breast-conserving therapy for ipsilateral breast cancer recurrence: A systematic review. Eur J Surg Oncol 2019; 45:1317-1327. [PMID: 30795956 DOI: 10.1016/j.ejso.2019.02.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Revised: 01/27/2019] [Accepted: 02/06/2019] [Indexed: 12/23/2022] Open
Abstract
The standard of care for patients with an ipsilateral breast tumour recurrence (IBTR) after breast-conserving therapy (BCT) is a salvage mastectomy. However, there is growing interest in the feasibility of repeat BCT for these patients. This systematic review contains the latest insights on BCT options for patients with an IBTR after initial BCT. A PubMed literature search was performed for articles on BCT options for IBTR after primary lumpectomy followed by radiotherapy. Weighted estimates were calculated for 5- and 10-year local control, distant metastasis-free and overall survival rates. Secondary outcomes were toxicity, cosmesis and quality of life. In total, 34 studies were eligible for analysis, of which 5 reported on repeat breast-conserving surgery (BCS) alone, 10 with mixed populations (BCS ± RT and/or mastectomy), 18 on repeat BCS followed by re-irradiation (whole-breast or partial) and one on quality of life. The weighted estimates for 5-year overall survival for repeat BCS and repeat BCS followed by reirradiation were 77% and 87%, respectively. Five-year local control was 76% for repeat BCS alone and 89% for repeat BCS followed by re-irradiation. Grade III-IV toxicity rates after re-irradiation varied from 0 to 21%, whereas the cosmesis was excellent-good in 29-100% of patients and unacceptable in 0-18%. Repeat BCS followed by re-irradiation, with either whole breast or partial breast re-irradiation, seems a feasible alternative to mastectomy in case of IBTR, in selected patients. Toxicity rates are low and the cosmetic outcome is good, but the size and follow-up of the published patient series is limited.
Collapse
|
46
|
Frequency and characteristics of additionally detected ipsilateral breast lesions following recall at screening mammography. Breast 2018; 42:94-101. [PMID: 30216838 DOI: 10.1016/j.breast.2018.08.104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 08/22/2018] [Accepted: 08/28/2018] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To determine the frequency and outcome of additionally detected ipsilateral breast abnormalities following recall at screening mammography. METHODS AND MATERIALS We included a consecutive series of 130,338 screening mammograms obtained between January 1, 2014 and January 1, 2016. During 2-year follow-up, clinical data were collected of all recalls. Women with a bilateral recall (115) and women recalled for multiple lesions in one breast (165) were excluded from the analyses. Screening outcome parameters were determined for recalled women with or without evaluation of additional ipsilateral breast abnormalities following recall. RESULTS A total of 3995 women were recalled (recall rate, 3.1%). In 258 (6.4%) of these women, another lesion was detected in the ipsilateral breast than the one for which she had been recalled. Biopsy was more frequently performed of additionally detected ipsilateral lesions than of recalled lesions (55.8% (144/258)) versus 39.7% (1375/3457), (p < 0.001)). The proportion of malignancy in recalled lesions and additionally detected lesions was comparable (21.5% (743/3457) versus 19.0% (49/258), p = 0.34). Of all 144 biopsies of additionally detected ipsilateral lesions, 9 revealed a synchronous tumour in addition to a malignant recalled lesion, and 33 biopsies revealed multicentric or multifocal tumours. In 5 women, the recalled lesion turned out to be benign, whereas the additional lesion in a different quadrant was malignant at biopsy. A total of 97 biopsies showed benign findings. CONCLUSION A substantial proportion of women are analyzed for additional ipsilateral breast lesions following recall. These lesions are more frequently biopsied than recalled lesions, but have a comparable probability of being malignant. The majority of additionally detected cancerous lesions are part of multifocal or multicentric malignancies.
Collapse
|
47
|
The rationale for and long-term outcome of incomplete axillary staging in elderly women with primary breast cancer. Eur J Surg Oncol 2018; 44:1714-1719. [PMID: 30082177 DOI: 10.1016/j.ejso.2018.07.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Revised: 06/26/2018] [Accepted: 07/08/2018] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND The proportion of elderly women diagnosed with breast cancer is rising. Standard treatment, including axillary staging, is often not given to these patients. This study aimed to investigate reasons to omit any surgical axillary staging or to refrain from completion axillary lymph node dissection (cALND) after positive-sentinel lymph node biopsy (SLNB); so-called "incomplete staging". Furthermore, the impact of incomplete staging on regional control and survival in patients aged 75 or older was evaluated. METHODS A retrospective cohort study was conducted including all primary breast cancer patients aged 75 or older, diagnosed between 2001 and 2008, and documented by the Netherlands Cancer Registry (NCR). Patients with incomplete staging were compared to patients with complete axillary staging. Survival analyses were used to determine the risk of local, regional and distant recurrence and overall survival. RESULTS In total, 1467 of 2116 (69%) patients were considered eligible, of whom 258 (17.2%) had incomplete axillary staging. For 93 patients, diagnosed in 6 of the 10 hospitals in the NCR-area, examination of clinical records revealed that age, comorbidities and patient preferences were the main reason for omitting complete axillary staging. The 10-year axillary recurrence rate in these 93 patients was 5.2% (95% CI, 0.03-10.1). Of the 77 patients who had died, 64 (83%) died of non-breast-cancer-related causes. No significant difference in overall survival was observed between patients with or without complete axillary staging. CONCLUSION This study demonstrates that the omission of complete axillary staging is common in selected elderly breast cancer patients with ≥2 comorbidities, with no apparent impact on regional control and 10-year overall survival.
Collapse
|
48
|
Impact of the second reader on screening outcome at blinded double reading of digital screening mammograms. Br J Cancer 2018; 119:503-507. [PMID: 30038325 PMCID: PMC6134129 DOI: 10.1038/s41416-018-0195-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 06/27/2018] [Accepted: 07/04/2018] [Indexed: 11/12/2022] Open
Abstract
Background To determine the impact of the second reader on screening outcome at blinded double reading of digital screening mammograms. Methods We included a consecutive series of 99,013 digital screening mammograms, obtained between July 2013 and January 2015 and double read in a blinded fashion. During 2-year follow-up, we collected radiology, surgery and pathology reports of recalled women. Results Single reading resulted in 2928 recalls and 616 screen-detected cancers (SDCs). The second reader recalled another 612 women, resulting in 82 additional SDCs. Addition of the second reader increased the recall rate (3.0% to 3.6%, p < 0.001), cancer detection rate (6.2–7.0 per 1000 screens, p < 0.001) and false positive recall rate (24.4–28.7 per 1000 screens, p < 0.001). Positive predictive value of recall (21.0% vs. 19.7%, p = 0.20) and of biopsy (52.1% vs. 50.9%, p = 0.56) were comparable for single reading and blinded double reading. Tumour characteristics were comparable for cancers detected by the first reader and cancers additionally detected by the second reader, except of a more favourable tumour grade in the latter group. Conclusions At blinded double reading, the second reader significantly increases the cancer detection rate, at the expense of an increased recall rate and false positive recall rate.
Collapse
|
49
|
Predicting breast and axillary response after neoadjuvant treatment for breast cancer: The role of histology vs receptor status. Breast J 2018; 24:894-901. [DOI: 10.1111/tbj.13085] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 10/21/2017] [Accepted: 10/31/2017] [Indexed: 11/28/2022]
|
50
|
Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography. Eur Radiol 2018; 29:337-344. [PMID: 29943181 DOI: 10.1007/s00330-018-5586-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Accepted: 06/04/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To analyse which mammographic and tumour characteristics led to concordant versus discordant recalls at blinded double reading to further optimise our breast cancer screening programme. METHODS We included a consecutive series of 99,013 screening mammograms obtained between July 2013 and January 2015. All mammograms were double read in a blinded fashion. Discordant readings were routinely recalled without consensus or arbitration. During the 2-year follow-up, relevant data of the recalled women were collected. We compared mammographic characteristics, screening outcome and tumour characteristics between concordant and discordant recalls. RESULTS There were 2,543 concordant recalls (71.4%) and 997 discordant recalls (28.0%). The positive predictive value of a concordant recall was significantly higher (23.5% vs. 10.0%, p < 0.001). The proportion of BI-RADS 0 was significantly higher in the discordant recall group (75.7% vs. 56.3%, p < 0.001). Discordant recalls were more often an asymmetry or architectural distortion (21.8% vs. 13.2% and 9.3% vs. 6.5%, respectively, p < 0.001). There were no differences in the distribution of DCIS and invasive cancers and tumour characteristics were comparable for the two groups, except for a more favourable tumour grade in the discordant recall group (54.7% vs. 39.9% grade I tumours, p = 0.022). CONCLUSIONS Screen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall. The higher proportion of asymmetries and architectural distortions in this group provide a possible target for improving screening programmes by additional training of screening radiologists and the implementation of digital breast tomosynthesis. KEY POINTS • With blinded double reading of screening mammograms, screen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall. • The proportions of asymmetries and architectural distortions are higher in case of a discordant reading. • Possible improvement strategies could target additional training of screening radiologists and the implementation of digital breast tomosynthesis in breast cancer screening programmes.
Collapse
|