The international reference system for beta-particle emitting radionuclides: Validation through the pilot study CCRI(II)-P1.Co-60. Appl Radiat Isot 2023; 200:110945. [PMID: 37515859 DOI: 10.1016/j.apradiso.2023.110945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/14/2023] [Accepted: 07/13/2023] [Indexed: 07/31/2023]
Abstract
The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.
Collapse
|
2
|
Measurement of the absolute gamma emission intensities from the decay of Th-229 in equilibrium with progeny. Appl Radiat Isot 2020; 166:109323. [PMID: 32795698 DOI: 10.1016/j.apradiso.2020.109323] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 07/02/2020] [Accepted: 07/05/2020] [Indexed: 10/23/2022]
Abstract
There are few long-lived radionuclides yielding high intensity gamma-rays emission with energies ranging from 100 keV to 500 keV that can be applied as radioactive gamma standard to calibrate HPGe detectors. Furthermore, this energy range represents the main emitted energies of the majority of radionuclides used in nuclear medicine. The Brazilian National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) has attempted to identify radionuclides that have the potential to be used as a calibration source due to their long half-life as well as their emission spectrum. Hence, LNMRI promotes standardization studies of gamma-emitting radionuclides that meet these criteria on order to disseminate them. Thorium-229, with its well-defined energies and relatively high intensities, is one such candidate radionuclide for the energy and full-energy peak efficiency calibration of high-purity gamma spectrometers. Thorium-229 was standardized by the method of 4παβ(LS)-γ(NaI(Tl)) live timed anticoincidence counting. The emission intensities of gamma-rays associated with the decay of 229Th have been determined by HPGe gamma ray spectrometry with accuracy and precision. The results are in agreement with current literature data.
Collapse
|
3
|
Metabolic Syndrome and Cognitive Function: Cross-Sectional Study on Community-Dwelling Non-Demented Older Adults in Japan. J Nutr Health Aging 2020; 24:878-882. [PMID: 33009539 DOI: 10.1007/s12603-020-1412-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
AIM This is a cross-sectional study of relation between metabolic syndrome and cognitive function in community-dwelling non-demented older adults in Japan. We examine the effect of metabolic syndrome and its components on global cognitive function. We also aim to clarify differences of specific cognitive domains between the subjects with and without metabolic syndrome. METHODS We studied 2150 subjects aged between 60 and 90 years whose scores on mini mental state examination (MMSE) were over 23 points. We analyzed difference in MMSE scores between the subjects with and without metabolic syndrome. Logistic regression analysis was performed with MMSE score as the dependent variable and metabolic syndrome components as the independent variable adjusted with age. We also examined differences in attention, logical memory, and verbal and category fluency between the subjects with and without metabolic syndrome. RESULTS MMSE scores were not significantly different between subjects with and without metabolic syndrome. In logistic regression analysis, the score of MMSE was significantly negatively associated with triglycerides in males and significantly negatively associated with abdominal circumference in females. Subjects with metabolic syndrome showed significantly lower performance of attention tasks compared to subjects without metabolic syndrome. CONCLUSIONS Our results suggest that in community-dwelling non-demented Japanese older adults, attention but not global cognitive function may be impaired by metabolic syndrome. Inverted association between some components of metabolic syndrome and global cognitive function indicate necessity of further studies on the relation between undernutrition and cognitive function.
Collapse
|
4
|
Results of an international comparison of activity measurements of 68Ge. Appl Radiat Isot 2018; 134:385-390. [PMID: 29248210 PMCID: PMC10996930 DOI: 10.1016/j.apradiso.2017.10.052] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2017] [Revised: 10/30/2017] [Accepted: 10/30/2017] [Indexed: 11/25/2022]
Abstract
An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)β-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.
Collapse
|
5
|
Standardization of 106 Ru/Rh by live-timed anticoincidence counting and gamma emission determination. Appl Radiat Isot 2017; 122:37-40. [DOI: 10.1016/j.apradiso.2017.01.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Revised: 01/03/2017] [Accepted: 01/11/2017] [Indexed: 11/26/2022]
|
6
|
Absolute standardization of the impurity 121 Te associated to the production of the radiopharmaceutical 123 I. Appl Radiat Isot 2016; 109:389-392. [DOI: 10.1016/j.apradiso.2015.12.056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2015] [Accepted: 12/28/2015] [Indexed: 10/22/2022]
|
7
|
Traceability from governmental producers of radiopharmaceuticals in measuring (18)F in Brazil. Appl Radiat Isot 2015; 109:236-241. [PMID: 26688362 DOI: 10.1016/j.apradiso.2015.11.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Accepted: 11/20/2015] [Indexed: 11/16/2022]
Abstract
Since the inception of its proficiency test program to evaluate radionuclide measurement in hospitals and clinics, the National Metrology Laboratory of Ionizing Radiation-LNMRI, that represents Brazilian National Metrology Institute (NMI) for ionizing radiation has expanded its measurement and calibration capability. Requirements from the National Health Surveillance Agency from Ministry of Health (ANVISA), to producers of radiopharmaceuticals provided an opportunity to improve the full traceability chain to the highest level. Fluorodeoxyglucose (FDG-(18)F) is the only radiopharmaceutical simultaneously produced by all Brazilian radiopharmaceutical production centers (RPCs). By running this proficiency test, LNMRI began to provide them with the required traceability. For evaluation, the ratio of RPC to reference value results and ISO/IEC17043:2010 criteria were used. The reference value established as calibration factor on the secondary standard ionization chamber was obtained from three absolute measurements systems, and routinely confirmed in each round of proficiency test by CIEMAT/NIST liquid scintillation counting. The γ-emitting impurities were checked using a High-Purity Germanium (HPGe) detector. The results show that Brazilian RPCs are in accordance with (accuracy within ±10%) the Brazilian standard for evaluation of measurements with radionuclide calibrators (CNEN NN 3.05., 2013). Nevertheless, the RPCs should improve the methodology of uncertainty estimates, essential when using the statistical criteria of ISO/IEC 17043 standard, in addition to improving accuracy to levels consistent with their position in the national traceability chain.
Collapse
|
8
|
Comparison of 99mTc activity measurements at LNMRI using SIRTI of the BIPM, a new instrument for comparing short-lived radionuclides. J Radioanal Nucl Chem 2015. [DOI: 10.1007/s10967-015-4317-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Calibration of ionization chamber for ¹⁸F and ⁶⁸Ga. Appl Radiat Isot 2014; 87:188-91. [PMID: 24361323 DOI: 10.1016/j.apradiso.2013.11.137] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 11/23/2013] [Indexed: 11/25/2022]
Abstract
In order to maintain the results of primary activity standardizations carried out in 2011 the LNMRI has determined the calibration factors for a pressurized 4π-ionization chamber for the nuclides (18)F and (68)Ga. This ionization chamber is coupled to a 6517A Keithley electrometer which is controlled by a homemade LabVIEW program. This paper will describe the main issues related to the calibration of an ionization chamber system for positron emitters and short half-life radionuclides such as timing, current measurement, background, decay, and (226)Ra check source measurements.
Collapse
|
10
|
Calibration of the LNMRI Secondary Standard Ionization Chamber for 131I capsules used in nuclear medicine. J Radioanal Nucl Chem 2012. [DOI: 10.1007/s10967-012-1660-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
11
|
Fatores de correção volumétrica na medição de atividade de 99mTc e 123I em calibradores de radionuclídeos. Radiol Bras 2012. [DOI: 10.1590/s0100-39842012000200006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJETIVO: Determinar os fatores de correção para a variação volumétrica dos radiofármacos contidos em recipientes de diferentes geometrias. Comparar a influência desses fatores na determinação da atividade de 99mTc e 123I utilizando dois tipos de calibradores: um com câmara de ionização e outro com detector Geiger-Müller (G-M). Avaliar o desempenho de calibradores de alguns serviços de medicina nuclear em medição de atividade de 99mTc e 123I. MATERIAIS E MÉTODOS: Foram utilizados oito calibradores, frascos de vidro 10R, seringas de plástico de 3 e 5 mL e soluções de 99mTc e 123I. Os fatores de correção foram determinados a partir das medições práticas da variação da leitura do calibrador com a variação do volume da solução no recipiente. O desempenho foi avaliado em relação ao critério de aceitação de ±10% de exatidão exigida pela norma brasileira. RESULTADOS: A variação da resposta do calibrador com a variação do volume do frasco foi bem maior no calibrador que utiliza G-M. Ela também foi maior para 123I do que para 99mTc. CONCLUSÃO: Os resultados confirmam que a resposta dos calibradores depende do volume contido nos recipientes. Essa dependência é mais crítica para os calibradores equipados com detector G-M e para 123I quando comparado com 99mTc.
Collapse
|
12
|
Standardization of 65Zn by sum-peak method. Appl Radiat Isot 2012; 70:2087-90. [PMID: 22425414 DOI: 10.1016/j.apradiso.2012.02.065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Accepted: 02/19/2012] [Indexed: 10/28/2022]
Abstract
A commercial solution of (65)Zn was standardized by the sum peak-method using a planar HPGe detector. The activity results were compared with measurements made with a well type 4πγ ionization chamber, which is traceable to BIPM.RI (II)-K2.Zn-65 key-comparison performed in 2002. The sum-peak value was 42.79 kBq/g and the ionization chamber value was 42.74 kBq/g both at the reference date. The uncertainty obtained in the sum peak standardization was 0.25% (k=1), and in the ionization chamber was 0.85% (k=1). The results showed that sum-peak method can be used in (65)Zn standardization and this method is easier, simpler and more practical than others methods.
Collapse
|
13
|
Standardization of (166m)Ho and 243Am/239Np by live-timed anti-coincidence counting with extending dead time. Appl Radiat Isot 2012; 70:2056-9. [PMID: 22417696 DOI: 10.1016/j.apradiso.2012.02.059] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Accepted: 02/19/2012] [Indexed: 10/28/2022]
Abstract
The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil acquired (166m)Ho and (243)Am/(239)Np solutions from commercial suppliers in order to realize primary standardization and therefore reducing the associated uncertainties. The method used in the standardization was the live-timed 4πβ(LS)-γ(ΝaI(Tl)) anticoincidence counting. The live-timed anticoincidence system is operated since 2006 in LNMRI and is composed of two MTR2 modules donated by Laboratoire National Henri Becquerel (LNE-LNHB)/France. The data acquisition system uses a homemade LabView program and an Excel file for calculus. These systems have been used for primary standardization at LNMRI for many radionuclides and recently took part in the (124)Sb and (177)Lu International Key Comparisons with good performance.
Collapse
|
14
|
Abstract
The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil participated in the last (57)Co activity measurement comparison organized by IAEA, in 2008. This was made in order to realize primary standardization of this radionuclide and to reduce the measuring uncertainties in the laboratory. Additionally, one sample with 2.6g was taken from the IAEA master solution of (57)Co and was prepared to be used in the measurement of the radionuclide's half-life in an ionization chamber system. The (57)Co half-life was measured to be 271.82 (17) days.
Collapse
|
15
|
|
16
|
|
17
|
Abstract
OBJETIVO: Avaliar o desempenho dos calibradores de radionuclídeos de 55 serviços de medicina nuclear brasileiros em medição de atividade de radiofármaco contendo 99Tc m. Testes de proficiência foram aplicados em 63 resultados originados do programa de comparação promovido pelo Laboratório Nacional de Metrologia das Radiações Ionizantes do Instituto de Radioproteção e Dosimetria. MATERIAIS E MÉTODOS: O desempenho foi avaliado em relação ao critério de aceitação de ±10% de exatidão exigido pela norma brasileira e também aos critérios estabelecidos pela ISO/IEC Guide 43-1, e classificado como "aceitável" ou "não aceitável". Amostras de 99Tc m usadas nas comparações foram fornecidas por alguns dos participantes e calibradas no Laboratório Nacional de Metrologia das Radiações Ionizantes para determinar o valor de referência da atividade. RESULTADOS: Esta comparação com o 99Tc m mostrou que o desempenho aceitável atendendo à exigência da norma regulatória foi de 82,5%, enquanto pelos critérios estabelecidos pela norma ISO/IEC 43-1 foi de 81,0%. Por outro lado, calibradores de radionuclídeos com detector Geiger-Müller apresentaram desempenho inferior quando comparados com os dotados com câmara de ionização. CONCLU-SÃO: Nesta comparação, a avaliação do desempenho baseada nos critérios da ISO/IEC 43-1, os quais são aplicados a laboratórios analíticos, apesar de serem mais restritivas, foi bastante consistente com o critério de exatidão exigido pela norma nacional.
Collapse
|
18
|
|
19
|
Primary activity standardization of (57)Co by sum-peak method. Appl Radiat Isot 2009; 67:1887-91. [PMID: 19505830 DOI: 10.1016/j.apradiso.2009.05.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2008] [Revised: 04/24/2009] [Accepted: 05/12/2009] [Indexed: 11/29/2022]
Abstract
The sum-peak method was applied to standardize a (57)Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.
Collapse
|
20
|
|
21
|
Standardization of 241Am, 124Sb and 131I by live-timed anti-coincidence counting with extending dead time. Appl Radiat Isot 2008; 66:886-9. [DOI: 10.1016/j.apradiso.2008.02.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
22
|
Proficiency tests in the determination of activity of radionuclides in radiopharmaceutical products measured by nuclear medicine services in 8 years of comparison programmes in Brazil. Appl Radiat Isot 2008; 66:981-7. [DOI: 10.1016/j.apradiso.2008.02.045] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
23
|
Standardization of 67Ga, 51Cr and 55Fe by live-timed anti-coincidence counting with extending dead time. Appl Radiat Isot 2008; 66:231-5. [PMID: 17904854 DOI: 10.1016/j.apradiso.2007.08.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2007] [Revised: 08/17/2007] [Accepted: 08/20/2007] [Indexed: 11/23/2022]
Abstract
In this work, the activity standardization of 51Cr, 55Fe and 67Ga by live-timed anti-coincidence counting with extending dead time is described. The difficulties of the method, the uncertainties of the results of the measurements and the comparison of these results with others measurement methods are discussed.
Collapse
|
24
|
Abstract
The Nuclear Medicine Services (NMS) in Brazil routinely use dose calibrators to measure the activity of solutions containing radiopharmaceuticals. These solutions are administered to patients with the intention to diagnose or treat illnesses. However, for optimal results, the activity of these radiopharmaceuticals must be determined as accurately as possible. The National Laboratory for Ionizing Radiation Metrology (LNMRI) led, since 1998, a comparison program for activity measurements of radiopharmaceuticals administered to patients in the NMS with the purpose promoting quality control. This program has been carried out successfully in Rio de Janeiro, but there is a need to implement it around the country. This can be resolved through the implementation of a network of regional laboratories at various locations throughout the national territory. Currently, such a network is active at a second site, located in Brasília, covering the needs of the Center-West Region, and at a third site, located in Porto Alegre, in the South Region. This work presents the results of comparisons for the radiopharmaceuticals nuclides 131I and 99Tcm and proves that the implementation of a radionuclide metrology network is feasible and viable.
Collapse
|
25
|
Abstract
The absolute 4pi-betagamma coincidence counting has been used to measure the activity concentrations of 54Mn and 203Hg, and the Sum-Peak method was used for 125I. 54Mn and 125I radionuclides have been part of international key-comparisons coordinated by the Bureau International des Poids et Measures (BIPM) in 2003/2004, while 203Hg is part of the traceability programme of the National Laboratory for Ionizing Radiation Metrology (LNMRI)/Brazil. Three different detectors were used for the Sum-Peak method: 3''x3'' NaI(Tl) and 5''x5'' well NaI(Tl) scintillation detectors and a planar germanium detector. Direct measurements were made of the photon emission probabilities of the 35.5-, 834.8- and 279.2-keV gamma-rays of 125I, 54Mn and 203Hg to give values of (0.0667+/-0.0014), (0.9997+/-0.0055) and (0.8161+/-0.0005), respectively. The half-lives of 203Hg and 54Mn were also determined by means of a 4pigamma ionization chamber (203Hg) and by the reference source method using a HPGe detector (54Mn) to give values of (46.639+/-0.023) days and (312.1+/-0.9) days, respectively.
Collapse
|
26
|
Activity characterization of 192Ir brachytherapy wires. J Radioanal Nucl Chem 2006. [DOI: 10.1007/s10967-006-0385-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
27
|
Determination of disintegration rates and γ-ray emission probabilities of 65Zn and 241Am. Appl Radiat Isot 2005; 63:107-13. [PMID: 15866455 DOI: 10.1016/j.apradiso.2005.01.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2004] [Revised: 01/21/2005] [Accepted: 01/31/2005] [Indexed: 10/25/2022]
Abstract
Radioactive solutions of (65)Zn and (241)Am were standardized within the frame of the CCRI (II)/BIPM key comparisons carried out recently in 2003. The activity concentrations (in Bqg(-1)) were determined using the 4pi(proportional counter)-gamma coincidence counting method with efficiency extrapolation. Liquid scintillation methods were also used for (241)Am activity determination. The 1115.5 keV of (65)Zn and the 26.35 and 59.54 keV of (241)Am gamma-ray emission probabilities were determined as 0.4971, 0.0206 and 0.3587, respectively, using a planar germanium detector. The associated relative uncertainties were 0.33%, 1.56% and 0.47%, respectively.
Collapse
|
28
|
Abstract
32P and 204Tl solutions were standardized within the frame of the international key comparisons organized by bureau international des poids et mesures, in 2002. The activity concentration of 32P was measured by counting solid sources in a 4pibeta proportional gas flow counter and by liquid scintillation counting. The self-absorption in solid sources for 4pibeta counting and the presence of 33P as an impurity were evaluated. The combined standard uncertainty for 32P was 0.59% in the 4pibeta counting and 0.38% in the liquid scintillation counting. Liquid scintillation counting was used to measure the activity concentration of 204Tl with combined standard uncertainty of 0.35%.
Collapse
|
29
|
Abstract
Since 1998, the National Laboratory for Ionizing Radiation Metrology has lead an intercomparison program for activity measurements of radiopharmaceuticals administered to patients in the Nuclear Medicine Services (NMS) with the purpose of promoting the quality control. In this work, intercomparison results with the radionuclides 67Ga, 123I, 99mTc and 201Tl from the beginning of the program to the present will be presented establishing as a consequence, the radionuclide calibrators' traceability used by the participants. The analysis of the results showed that 68% were within the limits of +/-10% required by the Brazilian Regulatory Authority that demands this accuracy band for the radiopharmaceutical measurements in the NMS. The results also demonstrate an improvement in the measurement quality that this program has provided since its beginning.
Collapse
|
30
|
Abstract
Efficiency calibration curves for germanium detectors are usually established by using a large number of standard gamma-ray sources of specific radionuclides, that decay with few gamma-rays, or radionuclides with complex decay schemes, such as 133Ba or 152Eu. But these multi-gamma radionuclides cannot be used alone, because the gamma-rays of high intensity are irregularly distributed across the energy spectrum. 166mHo is a more suitable single source for such calibrations, because this radionuclide decays by beta(-)emission to the excited states of 166Er with the subsequent emission of about 20 strong and well distributed gamma-rays ever the energy range 50-1000 keV. Moreover, with a relatively long half-life (1200 yr) and characteristic X-rays between 40 and 50 keV, this nuclide is a good standard for the calibration of germanium detectors. The X- and gamma-ray emission probabilities of their main lines need to be known with good accuracy in order to resolve the discrepancies found in the literature. A combination of 4pi beta-gamma coincidence and X- and gamma-ray spectrometric techniques have been used to determine 50 photon emission probabilities.
Collapse
|
31
|
Abstract
In order to obtain information on the accuracy of activity measurements in Brazilian hospitals, several intercomparison exercises have been organized since 1998. The first exercise consisted of two intercomparison runs of 131I and 99mTc and had the participation of 21 hospitals localized in Rio de Janeiro city and surroundings. The second, with 131I (47 hospitals) and 123I (12 hospitals), had the participation of hospitals localized in the whole country. The results were analyzed under the statistical point of view and conformity to the norms of Regulatory Authority. These results have shown that such exercises are necessary to improve the quality of the measurements and to identify those instruments that are producing incorrect values.
Collapse
|
32
|
Abstract
A solution of 152Eu was absolutely standardized by the 4pi beta (PPC)-gamma (HPGe) coincidence counting method as part of an intercomparison program coordinated by Bureau International des Poids et Mesures. The measured activity has been used to determine the calibration factor of the LNMRI reference ionization chamber for 152Eu. The half-life of 152Eu was also determined by means of a 4pi gamma ionization chamber to be (4963.6+/-15.3) days, and compared with others published values.
Collapse
|
33
|
Abstract
A solution of 169Yb was absolutely standardized by the 4pi(EC,X)-gamma coincidence counting method and the result was used to obtain direct measurements of gamma-ray emission probabilities with a coaxial HPGe detector. The empirical relation proposed by (Vaño, F., Gonzalez, L., Gaeta R., Gonzalez, J.A., 1975. An empirical function which relates the slope of the Ge efficiency curves and the active volume Nucl. Instr. Meth. 123, 573) was tested using the gamma spectral response above 200 keV. The half-life of 169Yb was also measured with a 4pi gamma ionization chamber.
Collapse
|
34
|
Abstract
This work outlines the quality assurance program for the activity measurements of the most used radionuclides at Brazilian Nuclear Medicine Services (NMS). The program aims to guarantee that the patient is given the correct prescribed amount of activity in diagnostic or therapeutic applications. This accurate administration depends upon proper use and calibration of the activity meters by the NMS. Underestimation of administered activity in diagnostic practices could delay correct diagnosis disturbing the value of the investigation. On the other hand, the overestimation would be worse, mainly in therapeutic applications, because an unnecessarily high absorbed dose would be delivered to the patient. The preliminary results of intercomparison for 131I and 99mTc showed that many activity meters used at NMS's present problems giving results up to 41% greater than the reference values determined at the National Metrology Laboratory for Ionizing Radiation (LNMRI) which is recognized as the Brazilian authorized metrology laboratory for ionizing radiation. These results have demonstrated that the NMS should improve the accuracy of the activity measurements of the radionuclides administered to the patients and establish the traceability to the national standards of measurements. These standards are based on a pressurized well-type ionization chamber installed at LNMRI and calibrated with reference sources standardized by absolute methods. The protocol of the intercomparison and recommendations made in order to minimize errors in measuring procedures are described and results are discussed.
Collapse
|
35
|
Abstract
How 352 Japanese university students regard web-site information was investigated by two kinds of survey. Application of correspondence analysis and cluster analysis to the questionnaire responses to the web-site advertisement showed students regarded a web-site as a new alien medium which is different from current media. Students regarded web-sites as simply complicated, intellectual, and impermanent, or not memorable. Students got precise information from web-sites but they did not use it in making decisions to purchase goods.