1
|
Identification of heavily glycated proteoforms by hydrophilic-interaction liquid chromatography and native size-exclusion chromatography - High-resolution mass spectrometry. Anal Chim Acta 2024; 1304:342543. [PMID: 38637052 DOI: 10.1016/j.aca.2024.342543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 03/20/2024] [Accepted: 03/25/2024] [Indexed: 04/20/2024]
Abstract
BACKGROUND The non-enzymatic glycation of proteins and their advanced glycation end products (AGEs) are associated with protein transformations such as in the development of diseases and biopharmaceutical storage. The characterization of heavily glycated proteins at the intact level is of high interest as it allows to describe co-occurring protein modifications. However, the high heterogeneity of glycated protein makes this process challenging, and novel methods are required to accomplish this. RESULTS In this study, we investigated two novel LC-HRMS methods to study glycated reference proteins at the intact protein level: low-flow hydrophilic-interaction liquid chromatography (HILIC) and native size-exclusion chromatography (SEC). Model proteins were exposed to conditions that favored extensive glycation and the formation of AGEs. After glycation, complicated MS spectra were observed, along with a sharply reduced signal response, possibly due to protein denaturation and the formation of aggregates. When using HILIC-MS, the glycated forms of the proteins could be resolved based on the number of reducing monosaccharides. Moreover, some positional glycated isomers were separated. The SEC-MS method under non-denaturing conditions provided insights into glycated aggregates but offered only a limited separation of glycated species based on molar mass. Overall, more than 25 different types of species were observed in both methods, differing in molar mass by 14-162 Da. 19 of these species have not been previously reported. SIGNIFICANCE The proposed strategies show great potential to characterize highly glycated intact proteins from native and denaturing perspectives and provide new opportunities for fast clinical diagnoses and investigating glycation-related diseases.
Collapse
|
2
|
Characterization of Complex Proteoform Mixtures by Online Nanoflow Ion-Exchange Chromatography-Native Mass Spectrometry. Anal Chem 2024. [PMID: 38771719 DOI: 10.1021/acs.analchem.4c01760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2024]
Abstract
The characterization of proteins and complexes in biological systems is essential to establish their critical properties and to understand their unique functions in a plethora of bioprocesses. However, it is highly difficult to analyze low levels of intact proteins in their native states (especially those exceeding 30 kDa) with liquid chromatography (LC)-mass spectrometry (MS). Herein, we describe for the first time the use of nanoflow ion-exchange chromatography directly coupled with native MS to resolve mixtures of intact proteins. Reference proteins and protein complexes with molecular weights between 10 and 150 kDa and a model cell lysate were separated using a salt-mediated pH gradient method with volatile additives. The method allowed for low detection limits (0.22 pmol of monoclonal antibodies), while proteins presented nondenatured MS (low number of charges and limited charge state distributions), and the oligomeric state of the complexes analyzed was mostly kept. Excellent chromatographic separations including the resolution of different proteoforms of large proteins (>140 kDa) and a peak capacity of 82 in a 30 min gradient were obtained. The proposed setup and workflows show great potential for analyzing diverse proteoforms in native top-down proteomics, opening unprecedented opportunities for clinical studies and other sample-limited applications.
Collapse
|
3
|
Comprehensive Two-Dimensional Liquid Chromatography-High-Resolution Mass Spectrometry for Complex Protein Digest Analysis Using Parallel Gradients. Anal Chem 2024. [PMID: 38758734 DOI: 10.1021/acs.analchem.4c02172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2024]
Abstract
Despite the high gain in peak capacity, online comprehensive two-dimensional liquid chromatography coupled with high-resolution mass spectrometry (LC × LC-HRMS) has not yet been widely applied to the analysis of complex protein digests. One reason is the method's reduced sensitivity which can be linked to the high flow rates of the second separation dimension (2D). This results in higher dilution factors and the need for flow splitters to couple to ESI-MS. This study reports proof-of-principle results of the development of an RPLC × RPLC-HRMS method using parallel gradients (2D flow rate of 0.7 mL min-1) and its comparison to shifted gradient methods (2D of 1.4 mL min-1) for the analysis of complex digests using HRMS (QExactive-Plus MS). Shifted and parallel gradients resulted in high surface coverage (SC) and effective peak capacity (SC of 0.6226 and 0.7439 and effective peak capacity of 779 and 757 in 60 min). When applied to a cell line digest sample, parallel gradients allowed higher sensitivity (e.g., average MS intensity increased by a factor of 3), allowing for a higher number of identifications (e.g., about 2600 vs 3900 peptides). In addition, reducing the modulation time to 10 s significantly increased the number of MS/MS events that could be performed. When compared to a 1D-RPLC method, parallel RPLC × RPLC-HRMS methods offered a higher separation performance (FHWH from 0.12 to 0.018 min) with limited sensitivity losses resulting in an increase of analyte identifications (e.g., about 6000 vs 7000 peptides and 1500 vs 1990 proteins).
Collapse
|
4
|
Online multimethod platform for comprehensive characterization of monoclonal antibodies in cell culture fluid from a single sample injection - Intact protein workflow. Anal Chim Acta 2024; 1287:342074. [PMID: 38182339 DOI: 10.1016/j.aca.2023.342074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/23/2023] [Accepted: 11/25/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Therapeutic monoclonal antibodies (mAbs) comprise a large structural variability with respect to charge, size and post-translational modifications. These critical quality attributes (CQAs) need to be assessed during and after the production of mAbs. This normally requires off-line purification and sample preparation as well as several chromatographic selectivities, which makes the whole process time-consuming and error-prone. To improve on this, we developed an integrated and automated multi-dimensional analytical platform for the simultaneous assessment of multiple CQAs of mAbs in cell culture fluid (CCF) from upstream processes. RESULTS The on-line system allows mAb characterization at the intact level, combining protein A affinity chromatography (ProtA) with size-exclusion, ion-exchange, and reversed-phase liquid chromatographic modes with UV and mass spectrometric detection. Multiple heart cuts of a single mAb elution band from ProtA are stored in 20-μL loops and successively sent to the multimethod options in the second dimension. ProtA loading and elution conditions and their compatibility with second-dimension LC modes were studied and optimized. Subsequently, heart-cutting and valve-switching schemes were investigated to achieve effective and reproducible analyses. The applicability of the developed workflow was demonstrated by the direct analysis (i.e. not requiring off-line sample preparation) of a therapeutic mAb in CCF, obtaining useful information on accurate molecular mass, glycosylation, and charge and size variants of the mAb product at the same time and in just over 1 h. SIGNIFICANCE The developed multidimensional platform is the first system that allows for multiple fractions from a single ProtA band to be characterized using different chromatographic selectivities in a single run allowing direct correlation between CQAs. The performance of the system is comparable to established off-line methods, fully compatible with upstream process samples, and provides a significant time-reduction of the characterization procedure.
Collapse
|
5
|
Sample transformation in online separations: how chemical conversion advances analytical technology. Chem Commun (Camb) 2023; 60:36-50. [PMID: 38053451 PMCID: PMC10729587 DOI: 10.1039/d3cc03599a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/13/2023] [Indexed: 12/07/2023]
Abstract
While the advent of modern analytical technology has allowed scientists to determine the complexity of mixtures, it also spurred the demand to understand these sophisticated mixtures better. Chemical transformation can be used to provide insights into properties of complex samples such as degradation pathways or molecular heterogeneity that are otherwise unaccessible. In this article, we explore how sample transformation is exploited across different application fields to empower analytical methods. Transformation mechanisms include molecular-weight reduction, controlled degradation, and derivatization. Both offline and online transformation methods have been explored. The covered studies show that sample transformation facilitates faster reactions (e.g. several hours to minutes), reduces sample complexity, unlocks new sample dimensions (e.g. functional groups), provides correlations between multiple sample dimensions, and improves detectability. The article highlights the state-of-the-art and future prospects, focusing in particular on the characterization of protein and nucleic-acid therapeutics, nanoparticles, synthetic polymers, and small molecules.
Collapse
|
6
|
Corrigendum to "Micro-flow size-exclusion chromatography for enhanced native mass spectrometry of proteins and protein complexes" [Anal. Chim. Acta 1266 (2023) 341324]. Anal Chim Acta 2023; 1276:341603. [PMID: 37573097 DOI: 10.1016/j.aca.2023.341603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/14/2023]
|
7
|
Micro-flow size-exclusion chromatography for enhanced native mass spectrometry of proteins and protein complexes. Anal Chim Acta 2023; 1266:341324. [PMID: 37244657 DOI: 10.1016/j.aca.2023.341324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 03/29/2023] [Accepted: 05/03/2023] [Indexed: 05/29/2023]
Abstract
Size-exclusion chromatography (SEC) employing aqueous mobile phases with volatile salts at neutral pH combined with native mass spectrometry (nMS) is a valuable tool to characterize proteins and protein aggregates in their native state. However, the liquid-phase conditions (high salt concentrations) frequently used in SEC-nMS hinder the analysis of labile protein complexes in the gas phase, necessitating higher desolvation-gas flow and source temperature, leading to protein fragmentation/dissociation. To overcome this issue, we investigated narrow SEC columns (1.0 mm internal diameter, I.D.) operated at 15-μL/min flow rates and their coupling to nMS for the characterization of proteins, protein complexes and higher-order structures (HOS). The reduced flow rate resulted in a significant increase in the protein-ionization efficiency, facilitating the detection of low-abundant impurities and HOS up to 230 kDa (i.e., the upper limit of the Orbitrap-MS instrument used). More-efficient solvent evaporation and lower desolvation energies allowed for softer ionization conditions (e.g., lower gas temperatures), ensuring little or no structural alterations of proteins and their HOS during transfer into the gas phase. Furthermore, ionization suppression by eluent salts was decreased, permitting the use of volatile-salt concentrations up to 400 mM. Band broadening and loss of resolution resulting from the introduction of injection volumes exceeding 3% of the column volume could be circumvented by incorporating an online trap-column containing a mixed-bed ion-exchange (IEX) material. The online IEX-based solid-phase extraction (SPE) or "trap-and-elute" set-up provided on-column focusing (sample preconcentration). This allowed the injection of large sample volumes on the 1-mm I.D. SEC column without compromising the separation. The enhanced sensitivity attained by the micro-flow SEC-MS, along with the on-column focusing achieved by the IEX precolumn, provided picogram detection limits for proteins.
Collapse
|
8
|
A high-performance electrochemical biosensor using an engineered urate oxidase. Chem Commun (Camb) 2023. [PMID: 37285304 DOI: 10.1039/d3cc01869e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We constructed a high-performance biosensor for detecting uric acid by immobilizing an engineered urate oxidase on gold nanoparticles deposited on a carbon-glass electrode. This biosensor showed a low limit-of-detection (9.16 nM), a high sensitivity (14 μA/μM), a wide range of linearity (50 nM-1 mM), and more than 28 days lifetime.
Collapse
|
9
|
Online Hydrophilic Interaction Chromatography (HILIC) Enhanced Top-Down Mass Spectrometry Characterization of the SARS-CoV-2 Spike Receptor-Binding Domain. Anal Chem 2022; 94:5909-5917. [PMID: 35380435 PMCID: PMC9003935 DOI: 10.1021/acs.analchem.2c00139] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 03/25/2022] [Indexed: 12/13/2022]
Abstract
SARS-CoV-2 cellular infection is mediated by the heavily glycosylated spike protein. Recombinant versions of the spike protein and the receptor-binding domain (RBD) are necessary for seropositivity assays and can potentially serve as vaccines against viral infection. RBD plays key roles in the spike protein's structure and function, and thus, comprehensive characterization of recombinant RBD is critically important for biopharmaceutical applications. Liquid chromatography coupled to mass spectrometry has been widely used to characterize post-translational modifications in proteins, including glycosylation. Most studies of RBDs were performed at the proteolytic peptide (bottom-up proteomics) or released glycan level because of the technical challenges in resolving highly heterogeneous glycans at the intact protein level. Herein, we evaluated several online separation techniques: (1) C2 reverse-phase liquid chromatography (RPLC), (2) capillary zone electrophoresis (CZE), and (3) acrylamide-based monolithic hydrophilic interaction chromatography (HILIC) to separate intact recombinant RBDs with varying combinations of glycosylations (glycoforms) for top-down mass spectrometry (MS). Within the conditions we explored, the HILIC method was superior to RPLC and CZE at separating RBD glycoforms, which differ significantly in neutral glycan groups. In addition, our top-down analysis readily captured unexpected modifications (e.g., cysteinylation and N-terminal sequence variation) and low abundance, heavily glycosylated proteoforms that may be missed by using glycopeptide data alone. The HILIC top-down MS platform holds great potential in resolving heterogeneous glycoproteins for facile comparison of biosimilars in quality control applications.
Collapse
|
10
|
Poly(acrylamide- co- N, N'-methylenebisacrylamide) Monoliths for High-Peak-Capacity Hydrophilic-Interaction Chromatography-High-Resolution Mass Spectrometry of Intact Proteins at Low Trifluoroacetic Acid Content. Anal Chem 2021; 93:16000-16007. [PMID: 34807576 PMCID: PMC8655738 DOI: 10.1021/acs.analchem.1c03473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
![]()
In this study, we
optimized a polymerization mixture to synthesize
poly(acrylamide-co-N,N′-methylenebisacrylamide) monolithic stationary phases for
hydrophilic-interaction chromatography (HILIC) of intact proteins.
Thermal polymerization was performed, and the effects of varying the
amount of cross-linker and the porogen composition on the separation
performance of the resulting columns were studied. The homogeneity
of the structure and the different porosities were examined through
scanning electron microscopy (SEM). Further characterization of the
monolithic structure revealed a permeable (Kf between 2.5 × 10–15 and 1.40 ×
10–13 m2) and polar stationary phase
suitable for HILIC. The HILIC separation performance of the different
columns was assessed using gradient separation of a sample containing
four intact proteins, with the best performing stationary phase exhibiting
a peak capacity of 51 in a gradient of 25 min. Polyacrylamide-based
materials were compared with a silica-based particulate amide phase
(2.7 μm core–shell particles). The monolith has no residual
silanol sites and, therefore, fewer sites for ion-exchange interactions
with proteins. Thus, it required lower concentrations of ion-pair
reagent in HILIC of intact proteins. When using 0.1% of trifluoroacetic
acid (TFA), the peak capacities of the two columns were similar (30
and 34 for the monolithic and packed column, respectively). However,
when decreasing the concentration of TFA to 0.005%, the monolithic
column maintained similar separation performance and selectivity (peak
capacity 23), whereas the packed column showed greatly reduced performance
(peak capacity 12), lower selectivity, and inability to elute all
four reference proteins. Finally, using a mobile phase containing
0.1% formic acid and 0.005% TFA, the HILIC separation on the monolithic
column was successfully hyphenated with high-resolution mass spectrometry.
Detection sensitivity for protein and glycoproteins was increased
and the amount of adducts formed was decreased in comparison with
separations performed at 0.1% TFA.
Collapse
|
11
|
Fast determination of functionality-type × molecular-weight distribution of propoxylates with varying numbers of hydroxyl end-groups using gradient-normal-phase liquid chromatography × ultra-high pressure size-exclusion chromatography. J Chromatogr A 2021; 1659:462644. [PMID: 34739964 DOI: 10.1016/j.chroma.2021.462644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/16/2021] [Accepted: 10/21/2021] [Indexed: 10/20/2022]
Abstract
Understanding the relation between chemical characteristics and properties of synthetic polymers is one of the challenges faced by analytical chemists in industry. This is a complex task, as polymers are not synthesized as single molecule, but are populations of chemically similar compounds with distributions over several properties. The latter include, for example, molecular weight, nature of end-groups (functionality), and chemical composition. In this paper, comprehensive two-dimensional liquid chromatography was used to determine the combined functionality-type and molecular-weight distributions of hydroxy‑functionalized propoxylates. Propoxylates derived from different initiators (one up to eight terminal hydroxyl groups) were separated in the first dimension using a gradient normal-phase LC separation (NPLC). In the second dimension ultra-high pressure size-exclusion chromatography separation (UHPSEC), further speciating distributions based on molecular size. The developed NPLC × SEC method with evaporative light-scattering detection can be used for the fast screening (< 30 min) of mutually dependent functionality-type and molecular-weight distributions of unknown propoxylates.
Collapse
|
12
|
MS-Based Allotype-Specific Analysis of Polyclonal IgG-Fc N-Glycosylation. Front Immunol 2020; 11:2049. [PMID: 32973813 PMCID: PMC7472933 DOI: 10.3389/fimmu.2020.02049] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/28/2020] [Indexed: 12/18/2022] Open
Abstract
Current approaches to study glycosylation of polyclonal human immunoglobulins G (IgG) usually imply protein digestion or glycan release. While these approaches allow in-depth characterization, they also result in a loss of valuable information regarding certain subclasses, allotypes and co-occuring post-translational modifications (PTMs). Unfortunately, the high variability of polyclonal IgGs makes their intact mass spectrometry (MS) analysis extremely challenging. We propose here a middle-up strategy for the analysis of the intact fragment crystallizable (Fc) region of human plasma IgGs, with the aim of acquiring integrated information of the N-glycosylation and other PTMs of subclasses and allotypes. Human plasma IgG was isolated using Fc-specific beads followed by an on-bead C H 2 domain digestion with the enzyme IdeS. The obtained mixture of Fc subunits was analyzed by capillary electrophoresis (CE) and hydrophilic interaction liquid chromatography (HILIC) hyphenated with MS. CE-MS provided separation of different IgG-subclasses and allotypes, while HILIC-MS allowed resolution of the different glycoforms and their oxidized variants. The orthogonality of these techniques was key to reliably assign Fc allotypes. Five individual donors were analyzed using this approach. Heterozygosis was observed in all the analyzed donors resulting in a total of 12 allotypes identified. The assignments were further confirmed using recombinant monoclonal IgG allotypes as standards. While the glycosylation patterns were similar within allotypes of the same subclass, clear differences were observed between IgG subclasses and donors, highlighting the relevance of the proposed approach. In a single analysis, glycosylation levels specific for each allotype, relative abundances of subclasses and information on co-occurring modifications are obtained. This middle-up method represents an important step toward a comprehensive analysis of immunoglobulin G-Fc variants.
Collapse
|
13
|
Confinement of Monolithic Stationary Phases in Targeted Regions of 3D-Printed Titanium Devices Using Thermal Polymerization. Anal Chem 2020; 92:2589-2596. [PMID: 31876153 PMCID: PMC7003155 DOI: 10.1021/acs.analchem.9b04298] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Accepted: 12/26/2019] [Indexed: 01/28/2023]
Abstract
In this study, we have prepared thermally initiated polymeric monolithic stationary phases within discrete regions of 3D-printed titanium devices. The devices were created with controllable hot and cold regions. The monolithic stationary phases were first locally created in capillaries inserted into the channels of the titanium devices. The homogeneity of the monolith structure and the interface length were studied by scanning a capacitively coupled conductivity contactless detector (C4D) along the length of the capillary. Homogeneous monolithic structures could be obtained within a titanium device equipped with a hot and cold jacket connected to two water baths. The confinement method was optimized in capillaries. The sharpest interfaces (between monolith and empty channel) were obtained with the hot region maintained at 70 °C and the cold region at 4 or 10 °C, with the latter temperature yielding better repeatability. The optimized conditions were used to create monoliths bound directly to the walls of the titanium channels. The fabricated monoliths were successfully used to separate a mixture of four intact proteins using reversed-phase liquid chromatography. Further chromatographic characterization showed a permeability (Kf) of ∼4 × 10-15 m2 and a total porosity of 60%.
Collapse
|
14
|
Increasing the Separation Capacity of Intact Histone Proteoforms Chromatography Coupling Online Weak Cation Exchange-HILIC to Reversed Phase LC UVPD-HRMS. J Proteome Res 2018; 17:3791-3800. [PMID: 30226781 PMCID: PMC6220366 DOI: 10.1021/acs.jproteome.8b00458] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
![]()
Top-down proteomics is an emerging
analytical strategy to characterize
combinatorial protein post-translational modifications (PTMs). However,
sample complexity and small mass differences between chemically closely
related proteoforms often limit the resolution attainable by separations
employing a single liquid chromatographic (LC) principle. In particular,
for ultramodified proteins like histones, extensive and time-consuming
fractionation is needed to achieve deep proteoform coverage. Herein,
we present the first online nanoflow comprehensive two-dimensional
liquid chromatography (nLC×LC) platform top-down mass spectrometry
analysis of histone proteoforms. The described two-dimensional LC
system combines weak cation exchange chromatography under hydrophilic
interaction LC conditions (i.e., charge- and hydrophilicity-based
separation) with reversed phase liquid chromatography (i.e., hydrophobicity-based
separation). The two independent chemical selectivities were run at
nanoflows (300 nL/min) and coupled online with high-resolution mass
spectrometry employing ultraviolet photodissociation (UVPD-HRMS).
The nLC×LC workflow increased the number of intact protein masses
observable relative to one-dimensional approaches and allowed characterization
of hundreds of proteoforms starting from limited sample quantities
(∼1.5 μg).
Collapse
|
15
|
Abstract
![]()
Recent
progress in top-down proteomics has driven the demand for
chromatographic methods compatible with mass spectrometry (MS) that
can separate intact proteins. Hydrophilic interaction liquid chromatography
(HILIC) has recently shown good potential for the characterization
of glycoforms of intact proteins. In the present study, we demonstrate
that HILIC can separate a wide range of proteins exhibiting orthogonal
selectivity with respect to reversed-phase LC (RPLC). However, the
application of HILIC to the analysis of low abundance proteins (e.g.,
in proteomics analysis) is hampered by low volume loadability, hindering
down-scaling of the method to column diameters below 2.1 mm. Moreover,
HILIC-MS sensitivity is decreased due to ion suppression from the
trifluoroacetic acid (TFA) often used as the ion-pair agent to improve
the selectivity and efficiency in the analysis of glycoproteins. Here,
we introduce a capillary-based HILIC-MS method that overcomes these
problems. Our method uses RPLC trap-columns to load and inject the
sample, circumventing issues of protein solubility and volume loadability
in capillary columns (200 μm ID). The low flow rates and use
of a dopant gas in the electrospray interface improve protein-ionization
efficiencies and reduce suppression by TFA. Overall, this allows the
separation and detection of small protein quantities (down to 5 ng
injected on column) as indicated by the analysis of a mixture of model
proteins. The potential of the new capillary HILIC-MS is demonstrated
by the analysis of a complex cell lysate.
Collapse
|
16
|
Optimizing separations in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2017; 41:68-98. [PMID: 29027363 PMCID: PMC5814945 DOI: 10.1002/jssc.201700863] [Citation(s) in RCA: 139] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 09/21/2017] [Accepted: 09/21/2017] [Indexed: 12/16/2022]
Abstract
Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations.
Collapse
|
17
|
Reducing Dilution and Analysis Time in Online Comprehensive Two-Dimensional Liquid Chromatography by Active Modulation. Anal Chem 2016; 88:1785-93. [PMID: 26709410 PMCID: PMC5373567 DOI: 10.1021/acs.analchem.5b04051] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 12/28/2015] [Indexed: 12/19/2022]
Abstract
Online comprehensive two-dimensional liquid chromatography (LC × LC) offers ways to achieve high-performance separations in terms of peak capacity (exceeding 1000) and additional selectivity to realize applications that cannot be addressed with one-dimensional chromatography (1D-LC). However, the greater resolving power of LC × LC comes at the price of higher dilutions (thus, reduced sensitivity) and, often, long analysis times (>100 min). The need to preserve the separation attained in the first dimension ((1)D) causes greater dilution for LC × LC, in comparison with 1D-LC, and long analysis times to sample the (1)D with an adequate number of second dimension separations. A way to significantly reduce these downsides is to introduce a concentration step between the two chromatographic dimensions. In this work we present a possible active-modulation approach to concentrate the fractions of (1)D effluent. A typical LC × LC system is used with the addition of a dilution flow to decrease the strength of the (1)D effluent and a modulation unit that uses trap columns. The potential of this approach is demonstrated for the separation of tristyrylphenol ethoxylate phosphate surfactants, using a combination of hydrophilic interaction and reversed-phase liquid chromatography. The modified LC × LC system enabled us to halve the analysis time necessary to obtain a similar degree of separation efficiency with respect to UHPLC based LC × LC and of 5 times with respect to HPLC instrumentation (40 compared with 80 and 200 min, respectively), while at the same time reducing dilution (DF of 142, 299, and 1529, respectively) and solvent consumption per analysis (78, 120, and 800 mL, respectively).
Collapse
|
18
|
Comprehensive Two-Dimensional Liquid Chromatography with Stationary-Phase-Assisted Modulation Coupled to High-Resolution Mass Spectrometry Applied to Proteome Analysis of Saccharomyces cerevisiae. Anal Chem 2015; 87:5387-94. [DOI: 10.1021/acs.analchem.5b00708] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
19
|
Single-Step Ugi Multicomponent Reaction for the Synthesis of Phosphopeptidomimetics. J Org Chem 2013; 78:10077-87. [DOI: 10.1021/jo401372x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|