1
|
Injury, illness, and emotion: A review of the motivational continuum from trauma through recovery from an ecological perspective. Brain Behav Immun Health 2023; 27:100586. [PMID: 36655055 PMCID: PMC9841046 DOI: 10.1016/j.bbih.2022.100586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 12/15/2022] [Accepted: 12/29/2022] [Indexed: 01/06/2023] Open
Abstract
Image 1.
Collapse
|
2
|
Snapshot volumetric imaging with engineered point-spread functions. OPTICS EXPRESS 2022; 30:33490-33501. [PMID: 36242384 DOI: 10.1364/oe.465113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 08/11/2022] [Indexed: 06/16/2023]
Abstract
The biological world involves intracellular and intercellular interactions that occur at high speed, at multiple scales and in three dimensions. Acquiring 3D images, however, typically requires a compromise in either spatial or temporal resolution compared to 2D imaging. Conventional 2D fluorescence imaging provides high spatial resolution but requires plane-by-plane imaging of volumes. Conversely, snapshot methods such as light-field microscopy allow video-rate imaging, but at the cost of spatial resolution. Here we introduce 3D engineered point-spread function microscopy (3D-EPM), enabling snapshot imaging of real-world 3D extended biological structures while retaining the native resolution of the microscope in space and time. Our new computational recovery strategy is the key to volumetrically reconstructing arbitrary 3D structures from the information encapsulated in 2D raw EPM images. We validate our technique on both point-like and extended samples, and demonstrate its power by imaging the intracellular motion of chloroplasts undergoing cyclosis in a sample of Egeria densa. Our technique represents a generalised computational methodology for 3D image recovery which is readily adapted to a diverse range of existing microscopy platforms and engineered point-spread functions. We therefore expect it to find broad applicability in the study of rapid biological dynamics in 3D.
Collapse
|
3
|
High-speed multi-objective Fourier ptychographic microscopy. OPTICS EXPRESS 2022; 30:29189-29205. [PMID: 36299099 DOI: 10.1364/oe.466075] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 07/11/2022] [Indexed: 06/16/2023]
Abstract
The ability of a microscope to rapidly acquire wide-field, high-resolution images is limited by both the optical performance of the microscope objective and the bandwidth of the detector. The use of multiple detectors can increase electronic-acquisition bandwidth, but the use of multiple parallel objectives is problematic since phase coherence is required across the multiple apertures. We report a new synthetic-aperture microscopy technique based on Fourier ptychography, where both the illumination and image-space numerical apertures are synthesized, using a spherical array of low-power microscope objectives that focus images onto mutually incoherent detectors. Phase coherence across apertures is achieved by capturing diffracted fields during angular illumination and using ptychographic reconstruction to synthesize wide-field, high-resolution, amplitude and phase images. Compared to conventional Fourier ptychography, the use of multiple objectives reduces image acquisition times by increasing the area for sampling the diffracted field. We demonstrate the proposed scaleable architecture with a nine-objective microscope that generates an 89-megapixel, 1.1 µm resolution image nine-times faster than can be achieved with a single-objective Fourier-ptychographic microscope. New calibration procedures and reconstruction algorithms enable the use of low-cost 3D-printed components for longitudinal biological sample imaging. Our technique offers a route to high-speed, gigapixel microscopy, for example, imaging the dynamics of large numbers of cells at scales ranging from sub-micron to centimetre, with an enhanced possibility to capture rare phenomena.
Collapse
|
4
|
Addressing phase-curvature in Fourier ptychography. OPTICS EXPRESS 2022; 30:22421-22434. [PMID: 36224940 DOI: 10.1364/oe.458657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 05/11/2022] [Indexed: 06/16/2023]
Abstract
In Fourier ptychography, multiple low resolution images are captured and subsequently combined computationally into a high-resolution, large-field of view micrograph. A theoretical image-formation model based on the assumption of plane-wave illumination from various directions is commonly used, to stitch together the captured information into a high synthetic aperture. The underlying far-field (Fraunhofer) diffraction assumption connects the source, sample, and pupil planes by Fourier transforms. While computationally simple, this assumption neglects phase-curvature due to non-planar illumination from point sources as well as phase-curvature from finite-conjugate microscopes (e.g., using a single-lens for image-formation). We describe a simple, efficient, and accurate extension of Fourier ptychography by embedding the effect of phase-curvature into the underlying forward model. With the improved forward model proposed here, quantitative phase reconstruction is possible even for wide fields-of-views and without the need of image segmentation. Lastly, the proposed method is computationally efficient, requiring only two multiplications: prior and following the reconstruction.
Collapse
|
5
|
Changes in Oxygenation Levels During Moderate Altitude Simulation (Hypoxia-Induced): A Pilot Study Investigating the Impact of Skin Pigmentation in Pulse Oximetry. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1395:391-396. [PMID: 36527668 DOI: 10.1007/978-3-031-14190-4_64] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The current COVID-19 pandemic has shown us that the pulse oximeter is a key medical device for monitoring blood-oxygen levels non-invasively in patients with chronic or acute illness. It has also emphasised limitations in accuracy for individuals with darker skin pigmentation, calling for new methods to provide better measurements. The aim of our study is to identify the impact of skin pigmentation on pulse oximeter measurements. We also explored the benefits of a multi-wavelength approach with an induced change of arterial oxygen saturation. A total of 20 healthy volunteers were recruited. We used time domain diffuse reflectance spectroscopy (TDDRS) from a broad band light source, collecting spectra from the index finger along with three different pulse oximeters used simultaneously for monitoring purposes. Five acute hypoxic events were induced by administering 11% FiO2, produced by a Hypoxico altitude training system, for 120 sec through a face mask with a one-way valve. Our multi-wavelength approach revealed a correlation between the signature of skin pigmentation and the dynamic range of oxygen saturation measurements. Principal component analysis (PCA) showed separation between a range of different pigmented volunteers (PC1 = 56.00%) and oxygen saturation (PC2 = 22.99%). This emphasises the need to take into account skin pigmentation in oximeter measurements. This preliminary study serves to validate the need to better understand the impact of skin pigmentation absorption on optical readings in pulse oximeters. Multi-wavelength approaches have the potential to enable robust and accurate measurements across diverse populations.
Collapse
|
6
|
Trans-scleral Illumination - The Future of Retinal Imaging? EPJ WEB OF CONFERENCES 2022. [DOI: 10.1051/epjconf/202226602007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
We report how illumination of the retina through the sclera enables the recording of high-contrast reflectance and fluorescence images of the retina, free of the cornea and lens glare and autofluoresence that degrades images recorded using traditional illumination through the pupil.
Collapse
|
7
|
Integrated neuroimmune processing of threat, injury, and illness: An ecological framework mapping social alienation onto lifetime health vulnerability. Brain Behav Immun Health 2021; 18:100349. [PMID: 34723222 PMCID: PMC8531850 DOI: 10.1016/j.bbih.2021.100349] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 09/17/2021] [Indexed: 11/23/2022] Open
Abstract
Social alienation is a pre-eminent ecological threat for humans. In clinical and social care settings its impact is acknowledged in conditions as diverse as severe mood disturbance, chronic pain, and metabolic non-communicable diseases. An integrated psychoneuroimmune perspective shows how threat, injury, healing, and recovery follow through as a continuous process, but accepted cultural and clinical paradigms separating mental from physical illness provide little common ground on which to analyse and apply this continuum in practice. By reviewing the ecological relationships between emotional threat, tissue dyshomeostasis and injury, infection, pain, and mood this article explores not only how primeval somatic responses underpin the evolutionary foundations of depression and somatisation, but also links them to escalating physical non-communicable disease through archived socioeconomic adversity (allostatic load). Social alienation (in the absence of trauma) may prime and activate this ancient repertoire in which sensitised responses lay the foundation for persistent maladaptive states of aversive sensory misinterpretation, behavioural avoidance, anhedonia, and neuroinflammation presenting as widespread non-nociceptive pain, non-pain somatisation, and severe depression. The ecological perspective illuminates perverse clinical presentations, shows how some approaches to care may facilitate self-reinforcement in maladaptive syndromes, and offers pointers for inclusive rehabilitative clinical and social care.
Collapse
|
8
|
Publisher Correction: Holistic Monte-Carlo optical modelling of biological imaging. Sci Rep 2020; 10:11440. [PMID: 32632216 PMCID: PMC7338541 DOI: 10.1038/s41598-020-68533-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
9
|
Multi-aperture imaging for flat cameras. OPTICS LETTERS 2020; 45:6182-6185. [PMID: 33186945 DOI: 10.1364/ol.405702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 10/02/2020] [Indexed: 06/11/2023]
Abstract
Imaging with high angular resolution requires large apertures and long focal lengths. This has prevented the integration of telephoto lenses into thin devices such as modern mobile phones. We report a camera module employing multiple rotated rectangular apertures and folding of the optical system into the plane of the camera, enabling an order-of-magnitude reduction in depth compared to traditional telephoto lenses. Multiple images are fused in the frequency domain to yield a single high-resolution image equivalent to that yielded by a single circular aperture. The diameter of this equivalent aperture may be several times wider than the depth of the camera module. We propose two architectures and present illustrative optical designs to demonstrate the concept. Simulations of raytraced image acquisition and computational image reconstruction demonstrate the potential for high-quality, high-resolution imaging from thin, flat lens modules.
Collapse
|
10
|
Transcriptional repression of PTEN in neural cells using CRISPR/dCas9 epigenetic editing. Sci Rep 2020; 10:11393. [PMID: 32647121 PMCID: PMC7347541 DOI: 10.1038/s41598-020-68257-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Accepted: 06/19/2020] [Indexed: 12/11/2022] Open
Abstract
After damage to the adult mammalian central nervous system (CNS), surviving neurons have limited capacity to regenerate and restore functional connectivity. Conditional genetic deletion of PTEN results in robust CNS axon regrowth, while PTEN repression with short hairpin RNA (shRNA) improves regeneration but to a lesser extent, likely due to suboptimal PTEN mRNA knockdown using this approach. Here we employed the CRISPR/dCas9 system to repress PTEN transcription in neural cells. We targeted the PTEN proximal promoter and 5' untranslated region with dCas9 fused to the repressor protein Krüppel-associated box (KRAB). dCas9-KRAB delivered in a lentiviral vector with one CRISPR guide RNA (gRNA) achieved potent and specific PTEN repression in human cell line models and neural cells derived from human iPSCs, and induced histone (H)3 methylation and deacetylation at the PTEN promoter. The dCas9-KRAB system outperformed a combination of four shRNAs targeting the PTEN transcript, a construct previously used in CNS injury models. The CRISPR system also worked more effectively than shRNAs for Pten repression in rat neural crest-derived PC-12 cells, and enhanced neurite outgrowth after nerve growth factor stimulation. PTEN silencing with CRISPR/dCas9 epigenetic editing may provide a new option for promoting axon regeneration and functional recovery after CNS trauma.
Collapse
|
11
|
Computational Optical Sensing and Imaging: feature issue introduction. OPTICS EXPRESS 2020; 28:18131-18134. [PMID: 32680013 DOI: 10.1364/oe.397510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Indexed: 06/11/2023]
Abstract
This Feature Issue includes 19 articles that highlight advances in the field of Computational Optical Sensing and Imaging. Many of the articles were presented at the 2019 OSA Topical Meeting on Computational Optical Sensing and Imaging held in Munich, Germany, on June 24-27. Articles featured in the issue cover a broad array of topics ranging from imaging through scattering media, imaging round corners and compressive imaging to machine learning for recovery of images.
Collapse
|
12
|
Twin-Airy Point-Spread Function for Extended-Volume Particle Localization. PHYSICAL REVIEW LETTERS 2020; 124:198104. [PMID: 32469536 DOI: 10.1103/physrevlett.124.198104] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2019] [Revised: 11/11/2019] [Accepted: 04/08/2020] [Indexed: 06/11/2023]
Abstract
The localization of point sources in optical microscopy enables nm-precision imaging of single-molecules and biological dynamics. We report a new method of localization microscopy using twin Airy beams that yields precise 3D localization with the key advantages of extended depth range, higher optical throughput, and potential for imaging higher emitter densities than are possible using other techniques. A precision of better than 30 nm was achieved over a depth range in excess of 7 μm using a 60×, 1.4 NA objective. An illustrative application to extended-depth-range blood-flow imaging in a live zebrafish is also demonstrated.
Collapse
|
13
|
Nimodipine Reduces Dysfunction and Demyelination in Models of Multiple Sclerosis. Ann Neurol 2020; 88:123-136. [PMID: 32293054 PMCID: PMC7737229 DOI: 10.1002/ana.25749] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 04/13/2020] [Accepted: 04/13/2020] [Indexed: 12/22/2022]
Abstract
Objective Treatment of relapses in multiple sclerosis (MS) has not advanced beyond steroid use, which reduces acute loss of function, but has little effect on residual disability. Acute loss of function in an MS model (experimental autoimmune encephalomyelitis [EAE]) is partly due to central nervous system (CNS) hypoxia, and function can promptly improve upon breathing oxygen. Here, we investigate the cause of the hypoxia and whether it is due to a deficit in oxygen supply arising from impaired vascular perfusion. We also explore whether the CNS‐selective vasodilating agent, nimodipine, may provide a therapy to restore function, and protect from demyelination in 2 MS models. Methods A variety of methods have been used to measure basic cardiovascular physiology, spinal oxygenation, mitochondrial function, and tissue perfusion in EAE. Results We report that the tissue hypoxia in EAE is associated with a profound hypoperfusion of the inflamed spinal cord. Treatment with nimodipine restores spinal oxygenation and can rapidly improve function. Nimodipine therapy also reduces demyelination in both EAE and a model of the early MS lesion. Interpretation Loss of function in EAE, and demyelination in EAE, and the model of the early MS lesion, seem to be due, at least in part, to tissue hypoxia due to local spinal hypoperfusion. Therapy to improve blood flow not only protects neurological function but also reduces demyelination. We conclude that nimodipine could be repurposed to offer substantial clinical benefit in MS. ANN NEUROL 2020 ANN NEUROL 2020;88:123–136
Collapse
|
14
|
Fourier ptychography: current applications and future promises. OPTICS EXPRESS 2020; 28:9603-9630. [PMID: 32225565 DOI: 10.1364/oe.386168] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 01/30/2020] [Indexed: 05/18/2023]
Abstract
Traditional imaging systems exhibit a well-known trade-off between the resolution and the field of view of their captured images. Typical cameras and microscopes can either "zoom in" and image at high-resolution, or they can "zoom out" to see a larger area at lower resolution, but can rarely achieve both effects simultaneously. In this review, we present details about a relatively new procedure termed Fourier ptychography (FP), which addresses the above trade-off to produce gigapixel-scale images without requiring any moving parts. To accomplish this, FP captures multiple low-resolution, large field-of-view images and computationally combines them in the Fourier domain into a high-resolution, large field-of-view result. Here, we present details about the various implementations of FP and highlight its demonstrated advantages to date, such as aberration recovery, phase imaging, and 3D tomographic reconstruction, to name a few. After providing some basics about FP, we list important details for successful experimental implementation, discuss its relationship with other computational imaging techniques, and point to the latest advances in the field while highlighting persisting challenges.
Collapse
|
15
|
Discussion on: Effects of ohio's opioid prescribing limit for the geriatric minimally injured trauma patient. Am J Surg 2020; 219:404-405. [PMID: 32199529 DOI: 10.1016/j.amjsurg.2020.02.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
16
|
Remote sensing of blood oxygenation using red-eye pupil reflection. Physiol Meas 2019; 40:12NT01. [PMID: 31805541 DOI: 10.1088/1361-6579/ab5f3b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To develop a technique for remote sensing of systemic blood oxygenation using red-eye pupil reflection. APPROACH The ratio of the intensities of light from the bright pupil reflections at oxygen sensitive and isosbestic wavelengths is shown to be sensitive to the oxygenation of blood in the eye. A conventional retinal camera, fitted with an image-replicating imaging spectrometer, was used at standoff range to record snapshot spectral images of the face and eyes at eight different wavelengths. In our pilot study we measured optical-density ratios (ODRs) of pupil reflections at wavelengths of 780 nm and 800 nm, simultaneous with pulse oximetry, for ten healthy human subjects under conditions of normoxia and mild hypoxia (15% oxygen). The low absorption at these infrared wavelengths localises the sensing to the choroid. We propose that this can be used for as a proxy for systemic oximetry. MAIN RESULTS A significant reduction (P < 0.001) in ODR of the pupil images was observed during hypoxia and returned to baseline on resumption of normoxia. We demonstrate that measurement of the choroidal ODR can be used to detect changes in blood oxygenation that correlate positively with pulse oximetry and with a noise-equivalent oximetry precision of 0.5%. SIGNIFICANCE We describe a new method to remotely and non-invasively sense the oxygen saturation of choroidal blood. The methodology provides a proxy for remote sensing of cerebral and systemic blood oxygenation. We demonstrate the technique at short range but it has potential for systemic oximetry at large standoff ranges.
Collapse
|
17
|
Holistic Monte-Carlo optical modelling of biological imaging. Sci Rep 2019; 9:15832. [PMID: 31676825 PMCID: PMC6825179 DOI: 10.1038/s41598-019-51850-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Accepted: 10/01/2019] [Indexed: 01/15/2023] Open
Abstract
The invention and advancement of biological microscopy depends critically on an ability to accurately simulate imaging of complex biological structures embedded within complex scattering media. Unfortunately no technique exists for rigorous simulation of the complete imaging process, including the source, instrument, sample and detector. Monte-Carlo modelling is the gold standard for the modelling of light propagation in tissue, but is somewhat laborious to implement and does not incorporate the rejection of scattered light by the microscope. On the other hand microscopes may be rigorously and rapidly modelled using commercial ray-tracing software, but excluding the interaction with the biological sample. We report a hybrid Monte-Carlo optical ray-tracing technique for modelling of complete imaging systems of arbitrary complexity. We make the software available to enable user-friendly and rigorous virtual prototyping of biological microscopy of arbitrary complexity involving light scattering, fluorescence, polarised light propagation, diffraction and coherence. Examples are presented for the modelling and optimisation of representative imaging of neural cells using light-sheet and micro-endoscopic fluorescence microscopy and imaging of retinal vasculature using confocal and non-confocal scanning-laser ophthalmoscopes.
Collapse
|
18
|
Phase and amplitude imaging with quantum correlations through Fourier Ptychography. Sci Rep 2019; 9:10445. [PMID: 31320691 PMCID: PMC6639395 DOI: 10.1038/s41598-019-46273-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 06/21/2019] [Indexed: 11/09/2022] Open
Abstract
Extracting as much information as possible about an object when probing with a limited number of photons is an important goal with applications from biology and security to metrology. Imaging with a few photons is a challenging task as the detector noise and stray light are then predominant, which precludes the use of conventional imaging methods. Quantum correlations between photon pairs has been exploited in a so called ‘heralded imaging scheme’ to eliminate this problem. However these implementations have so-far been limited to intensity imaging and the crucial phase information is lost in these methods. In this work, we propose a novel quantum-correlation enabled Fourier Ptychography technique, to capture high-resolution amplitude and phase images with a few photons. This is enabled by the heralding of single photons combined with Fourier ptychographic reconstruction. We provide experimental validation and discuss the advantages of our technique that include the possibility of reaching a higher signal to noise ratio and non-scanning Fourier Ptychographic acquisition.
Collapse
|
19
|
Computational optical sensing and imaging: introduction. APPLIED OPTICS 2019; 58:COS1-COS2. [PMID: 30874226 DOI: 10.1364/ao.58.00cos1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Indexed: 06/09/2023]
Abstract
The OSA Topical Meeting on Computational Optical Sensing and Imaging (COSI) was held June 25-June 28, 2018 in Orlando, Florida, USA, as part of the Imaging and Applied Optics Congress. In this feature issue, we present several papers that cover the techniques, topics, and advancements in the field presented at the COSI meeting highlighting the integration of opto-electric measurement and computational processing.
Collapse
|
20
|
High-speed extended-volume blood flow measurement using engineered point-spread function. BIOMEDICAL OPTICS EXPRESS 2018; 9:6444-6454. [PMID: 31065441 PMCID: PMC6490974 DOI: 10.1364/boe.9.006444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Accepted: 09/25/2018] [Indexed: 06/09/2023]
Abstract
Experimental characterization of blood flow in living organisms is crucial for understanding the development and function of cardiovascular systems, but there has been no technique reported for snapshot imaging of thick samples in large volumes with high precision. We have combined computational microscopy and the diffraction-free, self-bending property of Airy-beams to track fluorescent beads with sub-micron precision through an extended axial range (up to 600 μm) within the flowing blood of 3 days post-fertilization (dpf) zebrafish embryos. The spatial trajectories of the tracer beads within flowing blood were recorded during transit through both cardinal and intersegmental vessels, and the trajectories were found to be consistent with the segmentation of the vasculature recorded using selective-plane illumination microscopy (SPIM). This method provides sufficiently precise spatial and temporal measurement of 3D blood flow that has the potential for directly probing key biomechanical quantities such as wall shear stress, as well as exploring the fluidic repercussions of cardiovascular diseases. Although we demonstrate the technique for blood flow, the ten-fold better enhancement in the depth range offers improvements in a wide range of applications of high-speed precision measurement of fluid flow, from microfluidics through measurement of cell dynamics to macroscopic aerosol characterizations.
Collapse
|
21
|
Computational localization microscopy with extended axial range. OPTICS EXPRESS 2018; 26:7563-7577. [PMID: 29609310 DOI: 10.1364/oe.26.007563] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Accepted: 02/15/2018] [Indexed: 06/08/2023]
Abstract
A new single-aperture 3D particle-localization and tracking technique is presented that demonstrates an increase in depth range by more than an order of magnitude without compromising optical resolution and throughput. We exploit the extended depth range and depth-dependent translation of an Airy-beam PSF for 3D localization over an extended volume in a single snapshot. The technique is applicable to all bright-field and fluorescence modalities for particle localization and tracking, ranging from super-resolution microscopy through to the tracking of fluorescent beads and endogenous particles within cells. We demonstrate and validate its application to real-time 3D velocity imaging of fluid flow in capillaries using fluorescent tracer beads. An axial localization precision of 50 nm was obtained over a depth range of 120μm using a 0.4NA, 20× microscope objective. We believe this to be the highest ratio of axial range-to-precision reported to date.
Collapse
|
22
|
Combined high contrast and wide field of view in the scanning laser ophthalmoscope through dual detection of light paths. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-10. [PMID: 29098812 DOI: 10.1117/1.jbo.22.11.116002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Accepted: 10/11/2017] [Indexed: 06/07/2023]
Abstract
We demonstrate a multimode detection system in a scanning laser ophthalmoscope (SLO) that enables simultaneous operation in confocal, indirect, and direct modes to permit an agile trade between image contrast and optical sensitivity across the retinal field of view to optimize the overall imaging performance, enabling increased contrast in very wide-field operation. We demonstrate the method on a wide-field SLO employing a hybrid pinhole at its image plane, to yield a twofold increase in vasculature contrast in the central retina compared to its conventional direct mode while retaining high-quality imaging across a wide field of the retina, of up to 200 deg and 20 μm on-axis resolution.
Collapse
|
23
|
Implantation of Collagen Iv/Poly(2-Hydroxyethyl Methacrylate) Hydrogels Containing Schwann Cells into the Lesioned Rat Optic Tract. Cell Transplant 2017; 7:381-91. [PMID: 9710307 DOI: 10.1177/096368979800700406] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Poly (2-hydroxyethylmethacrylate) (PolyHEMA) hydrogels, when combined with extracellular matrix molecules and infiltrated with cultured Schwann cells, have the capability to induce CNS axonal regrowth after injury. We have further investigated these PolyHEMA hydrogels and their potential to bridge CNS injury sites. Collagen IV-impregnated hydrogels containing Schwann cells were implanted into the lesioned optic tract in 14 rats. On examination 2–4 months later, there was good adherence between the implants and CNS tissue, and large numbers of viable Schwann cells (S100+, GFAP+, Laminin+, and LNGFR+) were seen within the hydrogel matrices. Immunohistochemical analysis showed that the collagen IV-impregnated PolyHEMA hydrogels preferentially supported the transplanted Schwann cells and not host glial cells such as astrocytes (GFAP+) or oligodendroglia (CAII+). Macrophages (ED1+) were also seen within the sponge structure. Eighty-three percent of the implanted hydrogels contained RT97+ axons within their trabecular networks. Regrowing axons were associated with the transplanted Schwann cells and not with the small number of infiltrating astrocytes. RT97+ axons were traced up to 510 μm from the nearest host neuropil. These axons were sometimes myelinated by the transplanted Schwann cells and expressed the peripheral myelin marker Po+. WGA/HRP-labeled retinal axons were seen within transplanted hydrogel sponges, with 40% of the cases growing for distances up to 350–450 μm within the polymer network. The data indicate that impregnating PolyHEMA sponges with collagen IV can modify the host glial reaction and support the survival of transplanted Schwann cells. This study thus provides new information on how biomaterials could be used to modify and bridge CNS injury sites.
Collapse
|
24
|
Multispectral oximetry of murine tendon microvasculature with inflammation. BIOMEDICAL OPTICS EXPRESS 2017; 8:2896-2905. [PMID: 28663914 PMCID: PMC5480437 DOI: 10.1364/boe.8.002896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 04/13/2017] [Accepted: 04/24/2017] [Indexed: 06/07/2023]
Abstract
We report a novel multispectral imaging technique for localised measurement of vascular oxygen saturation (SO2) in vivo. Annular back-illumination is generated using a Schwarzchild-design reflective objective. Analysis of multispectral data is performed using a calibration-free oximetry algorithm. This technique is applied to oximetry in mice to measure SO2 in microvasculature supplying inflamed tendon tissue in the hind leg. Average SO2 for controls was 94.8 ± 7.0 % (N = 6), and 84.0 ± 13.5 % for mice with inflamed tendon tissue (N = 6). We believe this to be the first localised measurement of hypoxia in tendon microvasculature due to inflammation. Quantification of localised SO2 is important for the study of inflammatory diseases such as rheumatoid arthritis, where hypoxia is thought to play a role in pathogenesis.
Collapse
|
25
|
Abstract
The application of neurotrophic factors as a therapy to improve morphological and behavioral outcomes after experimental spinal cord injury (SCI) has been the focus of many studies. These studies vary markedly in the type of neurotrophic factor that is delivered, the mode of administration, and the location, timing, and duration of the treatment. Generally, the majority of studies have had significant success if neurotrophic factors are applied in or close to the lesion site during the acute or the subacute phase after SCI. Comparatively fewer studies have administered neurotrophic factors in order to directly target the somata of injured neurons. The mode of delivery varies between acute injection of recombinant proteins, subacute or chronic delivery using a variety of strategies including osmotic minipumps, cell-mediated delivery, delivery using polymer release vehicles or supporting bridges of some sort, or the use of gene therapy to modify neurons, glial cells, or precursor/stem cells. In this brief review, we summarize the state of play of many of the therapies using these factors, most of which have been undertaken in rodent models of SCI.
Collapse
|
26
|
A multispectral microscope for in vivo oximetry of rat dorsal spinal cord vasculature. Physiol Meas 2016; 38:205-218. [PMID: 28001129 DOI: 10.1088/1361-6579/aa5527] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Quantification of blood oxygen saturation (SO2) in vivo is essential for understanding the pathogenesis of diseases in which hypoxia is thought to play a role, including inflammatory disorders such as multiple sclerosis (MS) and rheumatoid arthritis (RA). We describe a low-cost multispectral microscope and oximetry technique for calibration-free absolute oximetry of surgically exposed blood vessels in vivo. We imaged the vasculature of the dorsal spinal cord in healthy rats, and varied inspired oxygen (FiO2) in order to evaluate the sensitivity of the imaging system to changes in SO2. The venous SO2 was calculated as 67.8 ± 10.4% (average ± standard deviation), increasing to 83.1 ± 11.6% under hyperoxic conditions (100% FiO2) and returning to 67.4 ± 10.9% for a second normoxic period; the venous SO2 was 50.9 ± 15.5% and 29.2 ± 24.6% during subsequent hypoxic states (18% and 15% FiO2 respectively). We discuss the design and performance of our multispectral imaging system, and the future scope for extending this oximetry technique to quantification of hypoxia in inflamed tissue.
Collapse
|
27
|
In vivo oximetry of human bulbar conjunctival and episcleral microvasculature using snapshot multispectral imaging. Exp Eye Res 2016; 149:48-58. [PMID: 27317046 DOI: 10.1016/j.exer.2016.06.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Revised: 05/11/2016] [Accepted: 06/13/2016] [Indexed: 10/21/2022]
Abstract
Multispectral imaging (MSI) is a well-established technique for non-invasive oximetry of retinal blood vessels, which has contributed to the understanding of a variety of retinal conditions, including glaucoma, diabetes, vessel occlusion, and retinal auto-regulation. We report the first study to use snapshot multi-spectral imaging (SMSI) for oximetry of the bulbar conjunctival and episcleral microvasculature in the anterior segment of the eye. We report the oxygen dynamics of the bulbar conjunctival and episcleral microvasculature at normoxia and at acute mild hypoxia conditions. A retinal-fundus camera fitted with a custom Image-Replicating Imaging Spectrometer was used to image the bulbar conjunctival and episcleral microvasculature in ten healthy human subjects at normoxia (21% Fraction of Inspired Oxygen [FiO2]) and acute mild hypoxia (15% FiO2) conditions. Eyelid closure was used to control oxygen diffusion between ambient air and the sclera surface. Four subjects were imaged for 30 seconds immediately following eyelid opening. Vessel diameter and Optical Density Ratio (ODR: a direct proxy for oxygen saturation) of vessels was computed automatically. Oximetry capability was validated using a simple phantom that mimicked the scleral vasculature. Acute mild hypoxia resulted in a decrease in blood oxygen saturation (SO2) (i.e. an increase in ODR) when compared with normoxia in both bulbar conjunctival (p < 0.001) and episcleral vessels (p = 0.03). Average episcleral diameter increased from 78.9 ± 8.7 μm (mean ± standard deviation) at normoxia to 97.6 ± 14.3 μm at hypoxia (p = 0.02). Diameters of bulbar conjunctival vessels showed no significant change from 80.1 ± 7.6 μm at normoxia to 80.6 ± 7.0 μm at hypoxia (p = 0.89). When exposed to ambient air, hypoxic bulbar conjunctival vessels rapidly reoxygenated due to oxygen diffusion from ambient air. Reoxygenation occured in an exponential manner, and SO2 reached normoxia baseline levels. The average ½ time to full reoxygenation was 3.4 ± 1.4 s. As a consequence of oxygen diffusion, bulbar conjunctival vessels will be highly oxygenated (i.e. close to 100% SO2) when exposed to ambient air. Episcleral vessels were not observed to undergo any significant oxygen diffusion, instead behaving similarly to pulse oximetry measurements. This is the first study to the image oxygen dynamics of bulbar conjunctival and episcleral microvasculature, and consequently, the first study to directly observe the rapid reoxygenation of hypoxic bulbar conjunctival vessels when exposed to ambient air. Oximetry of bulbar conjunctival vessels could potentially provide insight into conditions where oxygen dynamics of the microvasculature are not fully understood, such as diabetes, sickle-cell diseases, and dry-eye syndrome. Oximetry in the bulbar conjunctival and episcleral microvasculature could be complimentary or alternative to retinal oximetry.
Collapse
|
28
|
Abstract
Foveated imaging, such as that evolved by biological systems to provide high angular resolution with a reduced space-bandwidth product, also offers advantages for man-made task-specific imaging. Foveated imaging systems using exclusively optical distortion are complex, bulky, and high cost, however. We demonstrate foveated imaging using a planar array of identical cameras combined with a prism array and superresolution reconstruction of a mosaicked image with a foveal variation in angular resolution of 5.9:1 and a quadrupling of the field of view. The combination of low-cost, mass-produced cameras and optics with computational image recovery offers enhanced capability of achieving large foveal ratios from compact, low-cost imaging systems.
Collapse
|
29
|
Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging. JOURNAL OF MODERN OPTICS 2015; 62:1828-1838. [PMID: 26740737 PMCID: PMC4685623 DOI: 10.1080/09500340.2015.1045309] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Accepted: 04/20/2015] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985,2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a [Formula: see text] external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.
Collapse
|
30
|
Clinically Unsuspected Prion Disease Among Patients With Dementia Diagnoses in an Alzheimer's Disease Database. Am J Alzheimers Dis Other Demen 2015; 30:752-5. [PMID: 26320231 DOI: 10.1177/1533317515602218] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Brain tissue analysis is necessary to confirm prion diseases. Clinically unsuspected cases may be identified through neuropathologic testing. METHODS National Alzheimer's Coordinating Center (NACC) Minimum and Neuropathologic Data Set for 1984 to 2005 were reviewed. Eligible patients had dementia, underwent autopsy, had available neuropathologic data, belonged to a currently funded Alzheimer's Disease Center (ADC), and were coded as having an Alzheimer's disease clinical diagnosis or a nonprion disease etiology. For the eligible patients with neuropathology indicating prion disease, further clinical information, collected from the reporting ADC, determined whether prion disease was considered before autopsy. RESULTS Of 6000 eligible patients in the NACC database, 7 (0.12%) were clinically unsuspected but autopsy-confirmed prion disease cases. CONCLUSION The proportion of patients with dementia with clinically unrecognized but autopsy-confirmed prion disease was small. Besides confirming clinically suspected cases, neuropathology is useful to identify unsuspected clinically atypical cases of prion disease.
Collapse
|
31
|
Compact multi-aperture imaging with high angular resolution. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2015; 32:411-419. [PMID: 26366652 DOI: 10.1364/josaa.32.000411] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Previous reports have demonstrated that it is possible to emulate the imaging function of a single conventional lens with an N×N array of identical lenslets to provide an N-fold reduction in imaging-system track length. This approach limits the application to low-resolution imaging. We highlight how using an array of dissimilar lenslets, with an array width that can be much wider than the detector array, high-resolution super-resolved imaging is possible. We illustrate this approach with a ray-traced design and optimization of a long-wave infrared system employing a 3×3 array of freeform lenslets to provide a fourfold reduction in track length compared to a baseline system. Simulations of image recovery show that recovered image quality is comparable to that of the baseline system.
Collapse
|
32
|
Development of a cell-based treatment for long-term neurotrophin expression and spiral ganglion neuron survival. Neuroscience 2014; 277:690-9. [PMID: 25088914 DOI: 10.1016/j.neuroscience.2014.07.044] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 06/13/2014] [Accepted: 07/18/2014] [Indexed: 12/13/2022]
Abstract
Spiral ganglion neurons (SGNs), the target cells of the cochlear implant, undergo gradual degeneration following loss of the sensory epithelium in deafness. The preservation of a viable population of SGNs in deafness can be achieved in animal models with exogenous application of neurotrophins such as brain-derived neurotrophic factor (BDNF) and neurotrophin-3. For translation into clinical application, a suitable delivery strategy that provides ongoing neurotrophic support and promotes long-term SGN survival is required. Cell-based neurotrophin treatment has the potential to meet the specific requirements for clinical application, and we have previously reported that Schwann cells genetically modified to express BDNF can support SGN survival in deafness for 4 weeks. This study aimed to investigate various parameters important for the development of a long-term cell-based neurotrophin treatment to support SGN survival. Specifically, we investigated different (i) cell types, (ii) gene transfer methods and (iii) neurotrophins, in order to determine which variables may provide long-term neurotrophin expression and which, therefore, may be the most effective for supporting long-term SGN survival in vivo. We found that fibroblasts that were nucleofected to express BDNF provided the most sustained neurotrophin expression, with ongoing BDNF expression for at least 30 weeks. In addition, the secreted neurotrophin was biologically active and elicited survival effects on SGNs in vitro. Nucleofected fibroblasts may therefore represent a method for safe, long-term delivery of neurotrophins to the deafened cochlea to support SGN survival in deafness.
Collapse
|
33
|
Abstract
The angular resolution of many commercial imaging systems is limited, not by diffraction or optical aberrations, but by pixilation effects. Multiaperture imaging has previously demonstrated the potential for super-resolution (SR) imaging using a lenslet array and single detector array. We describe the practical demonstration of SR imaging using an array of 25 independent commercial-off-the-shelf cameras. This technique demonstrates the potential for increasing the angular resolution toward the diffraction limit, but without the limit on angular resolution imposed by the use of a single detector array.
Collapse
|
34
|
Light path-length distributions within the retina. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:36008. [PMID: 24615644 DOI: 10.1117/1.jbo.19.3.036008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2013] [Accepted: 02/03/2014] [Indexed: 06/03/2023]
Abstract
A Monte Carlo simulation of light propagation through the retina has been developed to understand the path-length distributions within the retinal vessel. For full-field illumination, the path-length distribution within the vessel comprises directly backscattered light and light that has passed once or twice through the vessel. The origins of these light path-length distributions can be better understood by investigating different combinations of single-point illumination and detection positions. Perhaps the most significant observation is that illumination at the edges of the vessel, rather than over the whole field of view, and detection directly above the vessel capture only the light that has taken a single pass through the vessel. This path-length distribution is tightly constrained around the diameter of the vessel and can potentially provide enhancements for oxygen saturation imaging. The method could be practically implemented using an offset-pinhole confocal imaging system or structured light illumination.
Collapse
|
35
|
Assessment of Acute Mild Hypoxia on Retinal Oxygen Saturation Using Snapshot Retinal Oximetry. ACTA ACUST UNITED AC 2013; 54:7538-43. [DOI: 10.1167/iovs.13-12624] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
36
|
Abstract
Substantial research effort in the spinal cord injury (SCI) field is directed towards reduction of secondary injury changes and enhancement of tissue sparing. However, pathway repair after complete transections, large lesions, or after chronic injury may require the implantation of some form of oriented bridging structure to restore tissue continuity across a trauma zone. These matrices or scaffolds should be biocompatible and create an environment that facilitates tissue growth and vascularization, and allow axons to regenerate through and beyond the implant in order to reconnect with "normal" tissue distal to the injury. The myelination of regrown axons is another important requirement. In this chapter, we describe recent advances in biomaterial technology designed to provide a terrain for regenerating axons to grow across the site of injury and/or create an environment for endogenous repair. Many different types of scaffold are under investigation; they can be biodegradable or nondegradable, natural or synthetic. Scaffolds can be designed to incorporate immobilized signaling molecules and/or used as devices for controlled release of therapeutic agents, including growth factors. These bridging structures can also be infiltrated with specific cell types deemed suitable for spinal cord repair.
Collapse
|
37
|
Holistic optical-digital hybrid-imaging design: wide-field reflective imaging. APPLIED OPTICS 2013; 52:3931-3936. [PMID: 23759840 DOI: 10.1364/ao.52.003931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2012] [Accepted: 04/26/2013] [Indexed: 06/02/2023]
Abstract
Reflective imaging systems are typically limited to small field angles in order to avoid overly large obscurations or off-axis aberrations. Reflective optics are often preferred in astronomy due to the associated lower weight and cost, as well as the absence of chromatic aberrations. Although these advantages are compelling, off-axis aberrations typically limit the field of view to a few degrees, while many imaging applications require a considerably larger useful field of view. A hybrid optical-digital design could alleviate the issues associated with wide-field reflective optics by exploiting the larger design freedom inherent in such systems. In this paper we demonstrate how a holistic design approach can enable reflective imaging systems with a consistently sharp image across a wide field of view.
Collapse
|
38
|
|
39
|
Regrowth of axons within Schwann cell-filled polycarbonate tubes implanted into the damaged optic tract and cerebral cortex of rats. Restor Neurol Neurosci 2012; 6:221-37. [PMID: 21551752 DOI: 10.3233/rnn-1994-6306] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The efficacy of Schwann cell-filled polycarbonate tubes as a bridging substrate for regrowing axons following lesions of the rat optic tract or cerebral cortex has been assessed after short (11-31 days) or long (82-119 days) survival times. Tubes were impregnated with Iaminin and poly-L-lysine, soaked in basic FGF and filled with Schwann cells. They were implanted into optic tract lesions in 34 rats aged 15-21 days and into cortical lesion cavities in 3 adult rats. Gelfoam soaked in basic FGF and Schwann cell conditioned medium was placed over the tubes. In one group of rats, axon regrowth into implants was assessed using neurofilament antibody RT97; antibodies to proteolipid protein, Po, Iaminin, the low-affinity nerve growth factor receptor (NGFr), S-100 and EDI were also used to study myelination and the cellular content of the tubes. In a second group of rats, anterograde tracing techniques were used to specifically identify host retinal axons within the implanted polymers. After long survival times, the relationships between regrown axons and cells inside the tubes were also examined ultrastructurally. In all implants examined immunohistochemically at short survival times, large numbers of RT97+ axons were found throughout the tubes, usually in association with Iaminin+, NGFr+ Schwann cells. At longer survival times, viable Schwann cells were still present, but tubes contained fewer axons and less cellular material. This material often formed a cord (200-250 μm thick) which extended the length of the implant. In the second group of rats, labelled retinal axons were found in 11 of the 16 implants that were attached to the dLGN. Axons regrew up to 1 mm but did not reach the distal (tectal) end of the implants. Interestingly, there was no evidence of myelinogenesis by either implanted Schwann cells or by host-derived oligodendroglia which had migrated into the tubes. Oligodendroglia were usually encircled by processes, many of which originated from Schwann cells, suggesting that the grafted cells may have been involved in isolating the central glia. The data show that Schwann cell-filled polycarbonate tubes provided a favourable milieu for axonal regeneration in the short term; however over time there was a decrease in the cellular and fibre content of the tubes. After intracranial implantation, an additional supporting matrix inside the polycarbonate tubes may aid in providing an environment conducive to the long term maintenance of regenerated retinal and other axons.
Collapse
|
40
|
Multichanneled finite-conjugate imaging. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2012; 29:921-927. [PMID: 22673423 DOI: 10.1364/josaa.29.000921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Multichanneled imaging systems rely on nonredundant images recorded by an array of low-resolution imagers to enable construction of a high-resolution image. We show how the varying degree of redundancy associated with imaging throughout the imaged volume effects image quality. Using ray-traced image simulations and a metric used as a proxy for human perception, we show that robust recovery of high-resolution images can be obtained by avoiding excessive redundancy and that this is a felicitous consequence of typical manufacturing tolerances.
Collapse
|
41
|
Validation of Human Whole Blood Oximetry, Using a Hyperspectral Fundus Camera with a Model Eye. ACTA ACUST UNITED AC 2011; 52:2851-9. [DOI: 10.1167/iovs.10-6217] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
42
|
Abstract
We describe the achromatization of Wollaston prisms to reduce the angular dispersion in the splitting angle. Analytical theory and ray-tracing modeling is presented. In an example application, a sixfold reduction in dispersion is achieved for wavelengths in the region 400 nm to 1.7 μm. Experimental proof of concept is demonstrated, and in an example application, the spectral dispersion of extended images recorded through cascaded Wollaston prisms is shown to be reduced by an order of magnitude.
Collapse
|
43
|
Experimental demonstration of hybrid imaging for miniaturization of an optical zoom lens with a single moving element. OPTICS LETTERS 2011; 36:969-971. [PMID: 21403745 DOI: 10.1364/ol.36.000969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We experimentally demonstrate a miniaturized zoom lens with a single moving element based on the concepts and analysis described in Opt. Express 17, 6118 (2009). We show that the implementation of either a cubic or a generalized cubic phase-modulation function makes miniaturization possible in addition to providing extended-depth-of-field imaging. We present recovered images for zoom lenses employing both phase-modulation functions and conclude that the generalized-cubic-phase function yields higher image quality without the artifacts present for the pure-cubic-phase function.
Collapse
|
44
|
Parametric blind-deconvolution algorithm to remove image artifacts in hybrid imaging systems. OPTICS EXPRESS 2010; 18:18035-18040. [PMID: 20721189 DOI: 10.1364/oe.18.018035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Hybrid imaging systems employing cubic phase modulation in the pupil-plane enable significantly increased depth of field, but artifacts in the recovered images are a major problem. We present a parametric blind-deconvolution algorithm, based on minimization of the high-frequency content of the restored image that enables recovery of artifact-free images for a wide range of defocus. We show that the algorithm enables robust matching of the image recovery kernel with the optical point-spread function to enable, for the first time, optimally low noise levels in recovered images.
Collapse
|
45
|
Analysis of depth-of-focus of synthetic aperture antenna arrays. OPTICS LETTERS 2010; 35:2046-2048. [PMID: 20548381 DOI: 10.1364/ol.35.002046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Interferometric synthetic aperture arrays (SAA) can be refocused at any range via digital processing of the raw data, called the visibility function. Such systems are sensitive, however, to ranging errors in digital refocusing. They, therefore, exhibit a limited depth of focus, because these errors are equivalent to introducing defocus in the system. We derive an analytical expression for the Strehl ratio of synthetic aperture arrays, which accounts for both the antenna voltage pattern and the focal shift factor encountered in imaging systems with a low Fresnel number. Assessment of the depth of focus of short-range imaging arrays is allowed and is illustrated for common array designs.
Collapse
|
46
|
Experimental demonstration of continuously variable optical encoding in a hybrid imaging system. OPTICS LETTERS 2010; 35:2100-2102. [PMID: 20548399 DOI: 10.1364/ol.35.002100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We demonstrate an experimental method to obtain a continuously variable hybrid imaging system that uses two generalized cubic phase masks, to enable real-time optimization of the trade between extended depth-of-field and noise gain. We obtain point-spread functions as a function of the rotation angle and show an example of optimization based on recovered image quality.
Collapse
|
47
|
Fidelity optimization for aberration-tolerant hybrid imaging systems. OPTICS EXPRESS 2010; 18:9220-9228. [PMID: 20588769 DOI: 10.1364/oe.18.009220] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Several phase-modulation functions have been reported to decrease the aberration variance of the modulation-transfer-function (MTF) in aberration-tolerant hybrid imaging systems. The choice of this phase-modulation function is crucial for optimization of the overall system performance. To prevent a significant loss in signal-to-noise ratio, it is common to enforce restorability constraints on the MTF, requiring trade of aberration-tolerance and noise-gain. Instead of optimizing specific MTF characteristics, we directly minimize the expected imaging-error of the joint design. This method is used to compare commonly used phase-modulation functions: the antisymmetric generalized cubic polynomial and fourth-degree rotational symmetric phase-modulation. The analysis shows how optimal imaging performance is obtained using moderate phase-modulation, and more importantly, the relative merits of the above functions.
Collapse
|
48
|
Image artifacts in hybrid imaging systems with a cubic phase mask. OPTICS EXPRESS 2010; 18:8207-8212. [PMID: 20588666 DOI: 10.1364/oe.18.008207] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We present the first analytical analysis of image artifacts in defocused hybrid imaging systems that employ a cubic phase-modulation function. We show that defocus artifacts have the form of image replications and are caused by a net phase modulation of the optical transfer function. Both numerical simulations and experimental images are presented that exhibit replication artifacts that are compatible with the analytical expressions.
Collapse
|
49
|
Novel phage peptides attenuate beta amyloid-42 catalysed hydrogen peroxide production and associated neurotoxicity. Neurobiol Aging 2010; 31:203-14. [PMID: 18472186 DOI: 10.1016/j.neurobiolaging.2008.03.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2007] [Revised: 03/17/2008] [Accepted: 03/26/2008] [Indexed: 11/19/2022]
Abstract
Amyloid-beta (Abeta) peptides play a central role in the pathogenesis of Alzheimer's disease. There is accumulating evidence that supports the notion that the toxicity associated with human Abeta (both 40 and 42) is dependent on its superoxide dismutase (SOD)-like activity. We developed a novel screening method involving phage display technology to identify novel peptides capable of inhibiting Abeta's neurotoxicity. Two random peptide libraries containing 6-mer and 15-mer peptide inserts were used and resulted in the identification of 25 peptides that bound human Abeta (40 or 42). Here, we show that two of the three most enriched peptides obtained significantly reduced Abeta42's SOD-like activity. A 15-mer peptide reduced Abeta42 neurotoxicity in a dose-dependent manner as evidenced by a reduction in LDH release. These findings were confirmed in the independent MTT assay. Furthermore, comparative analysis of the 15-mer peptide with Clioquinol, a known inhibitor of Abeta's metal-mediated redox activity, showed the 15-mer peptide to be equipotent to this metal chelator, under the same experimental conditions. These agents represent novel peptides that selectively target and neutralise Abeta-induced neurotoxicity and thus provide promising leads for rational drug development.
Collapse
|
50
|
Abstract
We describe the use of wavefront coding for the mitigation of optical aberrations in a thermal imaging system. Diffraction-limited imaging is demonstrated with a simple singlet which enables an approximate halving in length and mass of the optical system compared to an equivalent two-element lens.
Collapse
|