Mata VE, Passos SRL, Hökerberg YHM, Berardinelli GM, dos Santos MAB, Fukuoka LVB, Maciel ACFSR, dos Santos Rodrigues CD, da Silva Santos A, de Vasconcellos Carvalhaes de Oliveira R. Precisão e confiabilidade de um teste imuno-cromatográfico rápido NS1 para diagnóstico DENV-1 no ponto de atendimento e no laboratório.
BMC Infect Dis 2017;
17:594. [PMID:
28851293 PMCID:
PMC5576130 DOI:
10.1186/s12879-017-2679-z]
[Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 08/10/2017] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND
Rapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic.
METHODS
Cross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI).
RESULTS
At 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0-84.1) and specificity (Sp) was 87.0% (95% CI: 66.4-97.2). Sn in serum/laboratory was 82% (95% CI: 74.1-88.6) and Sp 100% (95% CI: 85.8-100). Positive likelihood ratio was 5.9 (95% CI: 2.0-17.0) for whole blood/POC and 19.8 (95% CI: 2.9-135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74-0.93) or different observers (k = 0.81, 95% CI: 0.72-0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%.
CONCLUSIONS
NS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen.
TRIAL REGISTRATION
UTN U1111-1145-9451 .
Collapse