1
|
Efficacy and safety of the Spiration Valve System™ for the treatment of severe emphysema in patients with Alpha-1 antitrypsin deficiency (EMPROVE). Respir Med 2024; 224:107565. [PMID: 38364975 DOI: 10.1016/j.rmed.2024.107565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 02/09/2024] [Accepted: 02/11/2024] [Indexed: 02/18/2024]
Abstract
OBJECTIVES Alpha-1 antitrypsin deficiency (AATD) is a hereditary condition associated with emphysema. This study analyzed the efficacy and safety of Spiration Valve System TM (SVS) among AATD patients with severe emphysema. METHODS This multicenter prospective study included 20 patients demonstrating AATD as assessed by quantitative levels of AAT and genotype containing two ZZ alleles. Most diseased lobe based on high resolution computed tomography was selected for treatment with endobronchial SVS. The change from baseline in forced expiratory volume in 1 s (FEV1) at 6 months (Primary outcome) and at 12 months, quality-of-life (QoL) measured by St. George's Respiratory Questionnaire (SGRQ) as health status, dyspnea scale measured by mMRC, Chronic obstructive pulmonary disease (COPD) Assessment Test (CAT), 36-item Short Form Health Survey (SF-36) physical component summary (PCS) and safety were assessed. RESULTS Lung function (FEV1) significantly improved at 6 months (P = 0.02); but did not reach statistical significance at 12 months (P = 0.22). Significant improvement was observed in dyspnea (at all time points), QoL measures (3, 6, and 12 months), CAT score and PCS of SF-36 (1, 3 and 6 months). Response rates based on minimal clinically important difference reached 50-80% for all variables. Overall, 4.4 valves/patient were used to isolate the target lobe, with a mean procedure time of 20.3 min. Serious adverse events included COPD exacerbations (5%), pneumonia (10%), pneumothorax (15%) and death (5%), occurring within first three months. CONCLUSION SVS endobronchial valve treatment showed improvement in lung function, dyspnea, and QoL in AATD patients with severe emphysema.
Collapse
|
2
|
Sustained Clinical Benefits of Spiration Valve System in Patients with Severe Emphysema: 24-Month Follow-Up of EMPROVE. Ann Am Thorac Soc 2024; 21:251-260. [PMID: 37948704 PMCID: PMC10848907 DOI: 10.1513/annalsats.202306-520oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Accepted: 11/10/2023] [Indexed: 11/12/2023] Open
Abstract
Rationale: Follow-up of patients with emphysema treated with endobronchial valves is limited to 3-12 months after treatment in prior reports. To date, no comparative data exist between treatment and control subjects with a longer follow-up. Objectives: To assess the durability of the Spiration Valve System (SVS) in patients with severe heterogeneous emphysema over a 24-month period. Methods: EMPROVE, a multicenter randomized controlled trial, presents a rigorous comparison between treatment and control groups for up to 24 months. Lung function, respiratory symptoms, and quality-of-life (QOL) measures were assessed. Results: A significant improvement in forced expiratory volume in 1 second was maintained at 24 months in the SVS treatment group versus the control group. Similarly, significant improvements were maintained in several QOL measures, including the St. George's Respiratory Questionnaire and the COPD Assessment Test. Patients in the SVS treatment group experienced significantly less dyspnea than those in the control group, as indicated by the modified Medical Research Council dyspnea scale score. Adverse events at 24 months did not significantly differ between the SVS treatment and control groups. Acute chronic obstructive pulmonary disease exacerbation rates in the SVS treatment and control groups were 13.7% (14 of 102) and 15.6% (7 of 45), respectively. Pneumothorax rates in the SVS treatment and control groups were 1.0% (1 of 102) and 0.0% (0 of 45), respectively. Conclusions: SVS treatment resulted in statistically significant and clinically meaningful durable improvements in lung function, respiratory symptoms, and QOL, as well as a statistically significant reduction in dyspnea, for at least 24 months while maintaining an acceptable safety profile. Clinical trial registered with www.clinicaltrials.gov (NCT01812447).
Collapse
|
3
|
Transbronchial Lung Cryobiopsy and Surgical Lung Biopsy: A Prospective Multi-Centre Agreement Clinical Trial (CAN-ICE). Am J Respir Crit Care Med 2023; 207:1612-1619. [PMID: 36796092 DOI: 10.1164/rccm.202209-1812oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Accepted: 02/16/2023] [Indexed: 02/18/2023] Open
Abstract
Rationale: Transbronchial cryobiopsy (TBCB) for the diagnosis of interstitial lung disease (ILD) has shown promising results, but prospective studies with matched surgical lung biopsy (SLB) have yielded conflicting results. Objectives: We aimed to assess within- and between-center diagnostic agreement between TBCB and SLB at both the histopathologic and multidisciplinary discussion (MDD) levels in patients with diffuse ILD. Methods: In a multicenter prospective study, we performed matched TBCB and SLB in patients referred for SLB. After a blinded review by three pulmonary pathologists, all cases were reviewed by three independent ILD teams in an MDD. MDD was performed first with TBCB, then with SLB in a second session. Within-center and between-center diagnostic agreement was evaluated using percentages and correlation coefficients. Measurements and Main Results: Twenty patients were recruited and underwent contemporaneous TBCB and SLB. Within-center diagnostic agreement between TBCB-MDD and SLB-MDD was reached in 37 of the 60 (61.7%) paired observations, resulting in a Cohen's κ value of 0.46 (95% confidence interval [CI], 0.29-0.63). Diagnostic agreement increased among high-confidence or definitive diagnoses on TBCB-MDD (21 of 29 [72.4%]), but not significantly, and was more likely among cases with SLB-MDD diagnoses of idiopathic pulmonary fibrosis than fibrotic hypersensitivity pneumonitis (13 of 16 [81.2%] vs. 16 of 31 [51.6%]; P = 0.047). Between-center agreement for cases was markedly higher for SLB-MDD (κ = 0.71 [95% CI, 0.52-0.89]) than TBCB-MDD (κ = 0.29 [95% CI, 0.09-0.49]). Conclusions: This study demonstrated moderate TBCB-MDD and SLB-MDD diagnostic agreement for ILD, while between-center agreement was fair for TBCB-MDD and substantial for SLB-MDD. Clinical trial registered with www.clinicaltrials.gov (NCT02235779).
Collapse
|
4
|
Improving Lung Function in Severe Heterogenous Emphysema with the Spiration Valve System (EMPROVE). A Multicenter, Open-Label Randomized Controlled Clinical Trial. Am J Respir Crit Care Med 2020; 200:1354-1362. [PMID: 31365298 PMCID: PMC6884033 DOI: 10.1164/rccm.201902-0383oc] [Citation(s) in RCA: 90] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Rationale: Less invasive, nonsurgical approaches are needed to treat severe emphysema. Objectives: To evaluate the effectiveness and safety of the Spiration Valve System (SVS) versus optimal medical management. Methods: In this multicenter, open-label, randomized, controlled trial, subjects aged 40 years or older with severe, heterogeneous emphysema were randomized 2:1 to SVS with medical management (treatment) or medical management alone (control). Measurements and Main Results: The primary efficacy outcome was the difference in mean FEV1 from baseline to 6 months. Secondary effectiveness outcomes included: difference in FEV1 responder rates, target lobe volume reduction, hyperinflation, health status, dyspnea, and exercise capacity. The primary safety outcome was the incidence of composite thoracic serious adverse events. All analyses were conducted by determining the 95% Bayesian credible intervals (BCIs) for the difference between treatment and control arms. Between October 2013 and May 2017, 172 participants (53.5% male; mean age, 67.4 yr) were randomized to treatment (n = 113) or control (n = 59). Mean FEV1 showed statistically significant improvements between the treatment and control groups—between-group difference at 6 and 12 months, respectively, of 0.101 L (95% BCI, 0.060–0.141) and 0.099 L (95% BCI, 0.048–0.151). At 6 months, the treatment group had statistically significant improvements in all secondary endpoints except 6-minute-walk distance. Composite thoracic serious adverse event incidence through 6 months was greater in the treatment group (31.0% vs. 11.9%), primarily due to a 12.4% incidence of serious pneumothorax. Conclusions: In patients with severe heterogeneous emphysema, the SVS shows significant improvement in multiple efficacy outcomes, with an acceptable safety profile. Clinical trial registered with www.clinicaltrials.gov (NCT01812447).
Collapse
|
5
|
A Rare Complication: Development of an Aspergilloma after Endobronchial Coil Placement in a COPD Patient. Respiration 2019; 99:423-425. [PMID: 31622972 DOI: 10.1159/000503363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 09/14/2019] [Indexed: 11/19/2022] Open
Abstract
Endobronchial coils are a relatively novel endoscopic lung volume reduction modality that aims to increase functional capacity in chronic obstructive pulmonary disease (COPD) patients. Two major trials have studied the safety and efficacy of this therapy, but long-term safety has not been studied. Adverse events reported are mainly periprocedural pneumothoraces and early bacterial infectious complications. We report the case of a patient with severe emphysema (Global Initiative for Chronic Obstructive Lung Disease stage IV COPD) who developed endobronchial coil-associated aspergillomas 3 years after coil placement.
Collapse
|
6
|
P.390Pulmonary function in patients with Duchenne muscular dystrophy from the STRIDE registry and the CINRG natural history study: a matched cohort analysis. Neuromuscul Disord 2019. [DOI: 10.1016/j.nmd.2019.06.552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
7
|
Simplified Criteria Using Pleural Fluid Cholesterol and Lactate Dehydrogenase to Distinguish between Exudative and Transudative Pleural Effusions. Respiration 2019; 98:48-54. [PMID: 30826806 DOI: 10.1159/000496396] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 12/19/2018] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND An important part of the investigation of pleural effusion is the identification of markers that help separate exudate from transudate. OBJECTIVES The purposes of this study were to compare the accuracy of published and new sets of criteria to distinguish between exudative and transudative pleural effusions, and to determine whether serum biochemical analysis is necessary. METHODS An externally validated cohort study was performed. Pleural effusions were determined to be transudative or exudative on the basis of an assessment of the medical record by two clinicians blinded to biochemical results. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the receiver operating characteristic curve were determined for each proposed combination of criteria. RESULTS Pleural fluid analysis was available for 311 thoracenteses in the main cohort and for 112 thoracenteses in the validation cohort. The best sensitivity (97% [95% CI 94-99]) and negative likelihood ratio (0.04 [95% CI 0.02-0.08]) for identifying exudative effusions were observed with criteria combining pleural fluid lactate dehydrogenase greater than 0.6 the upper limit of normal serum lactate dehydrogenase and pleural fluid cholesterol greater than 1.04 mmol/L (40 mg/dL). The overall diagnostic accuracy was similar to Light's criteria. Findings were similar in the validation cohort. CONCLUSIONS Our proposed criteria using simultaneously pleural fluid lactate dehydrogenase and pleural fluid cholesterol can identify an exudate with a sensitivity and an overall diagnostic accuracy similar to Light's criteria. It avoids simultaneous blood sampling, thus reducing patient discomfort and potential costs.
Collapse
|
8
|
Predictors of Response to Endobronchial Coil Therapy in Patients With Advanced Emphysema. Chest 2019; 155:928-937. [PMID: 30797746 DOI: 10.1016/j.chest.2019.02.012] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 01/16/2019] [Accepted: 02/01/2019] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND The Lung Volume Reduction Coil Treatment in Patients With Emphysema (RENEW) trial reported improvements in quality of life, pulmonary function, and exercise performance following endobronchial coil treatment. OBJECTIVES The purpose of this post hoc analysis was to identify baseline predictors, including quantitative CT measures, that identify patients most likely to significantly benefit from endobronchial coil therapy. METHODS Quantitative CT analysis by an independent radiology laboratory and a qualitative evaluation by five blinded experts of the baseline thoracic CT imaging were performed. Univariate and multivariate logistic regression analyses were performed to elucidate characteristics associated with clinical response. RESULTS In total, 125 patients underwent coil treatment and had evaluable 12-month follow-up results. Of these, 78 patients received treatment of lobes with the highest emphysematous destruction determined by quantitative CT analysis (quantitative visual match [QVM]+), and 47 received treatment in at least one lobe that was not the most destroyed (QVM-). From the 78 patients with QVM+ treatment, a subgroup of 50 patients (64%) was identified with baseline residual volume > 200% predicted, emphysema score > 20% low attenuation area, and absence of airway disease. In this subgroup, greater lobar residual volume reduction in the treated lobes was achieved, which was associated with significant mean ± SE improvement in FEV1 (15.2 ± 3.1%), St. George's Respiratory Questionnaire (-12 ± 2 points), and residual volume (-0.57 ± 0.13 L). DISCUSSION This post hoc analysis found that both significant hyperinflation (residual volume ≥ 200% predicted) and CT analysis are critical for patient selection and treatment planning for endobronchial coil therapy. Quantitative CT analysis is important to identify optimal lobar treatment and to exclude patients with insufficient emphysema (< 20% low attenuation area), whereas visual assessment identifies patients with signs of airway disease associated with worse outcomes. TRIAL REGISTRY ClinicalTrials.gov; No.: NCT01608490; URL: www.clinicaltrials.gov.
Collapse
|
9
|
DMD CLINICAL THERAPIES I. Neuromuscul Disord 2018. [DOI: 10.1016/j.nmd.2018.06.140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Abstract
Hemoptysis is a frequent manifestation of a wide variety of diseases, with mild to life-threatening presentations. The diagnostic workup and the management of severe hemoptysis are often challenging. Advances in endoscopic techniques have led to different new therapeutic approaches. Cold saline, vasoconstrictive and antifibrinolytic agents, oxidized regenerated cellulose, biocompatible glue, laser photocoagulation, argon plasma coagulation, and endobronchial stents and valves are amongst the tools available to the bronchoscopist. In this article, we review the evidence regarding the definition, etiology, diagnostic modalities, and treatment of severe hemoptysis in the modern era with emphasis on bronchoscopic techniques.
Collapse
|
11
|
Outcomes of a Canadian Cohort of Subjects Treated With Lung Volume Reduction Coils: Analysis From the Renew Study. Chest 2017. [DOI: 10.1016/j.chest.2017.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
12
|
|
13
|
Influence of trainee involvement on procedural characteristics for linear endobronchial ultrasound. Thorac Cancer 2017; 8:517-522. [PMID: 28731576 PMCID: PMC5582462 DOI: 10.1111/1759-7714.12481] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 06/14/2017] [Accepted: 06/17/2017] [Indexed: 12/25/2022] Open
Abstract
Background Linear endobronchial ultrasound (EBUS) is a safe and effective method for the diagnostic sampling of mediastinal lymph nodes. However, there is a learning curve associated with the procedure and operator experience influences diagnostic yield. We sought to determine if trainee involvement during EBUS influences procedural characteristics, complication rate, and diagnostic yield. Methods We performed a retrospective analysis of 220 subjects who underwent an EBUS procedure at our center from December 2012 to June 2013. Procedures were performed by six different interventional pulmonologists with substantial experience with EBUS or by a trainee under their direct supervision. Procedural characteristics and complications were recorded. Diagnostic yield and specimen adequacy were compared between groups. Results EBUS was performed in 220 patients with a trainee involved (n = 116) or by staff physician alone (n = 104). Patient characteristics, and the number and size of lymph node stations sampled were similar. EBUS duration was longer (16.0 vs. 13.7 minutes; P = 0.002) and the total dose of lidocaine used was higher (322.3 vs. 304.2 mg; P = 0.045) when a trainee was involved. The rate of adequate specimens sampled was comparable between the groups (92.0 vs. 92.0%; P = 0.60). Diagnostic yield was lower when a trainee was involved in the EBUS procedure (52.6 vs. 68.3%; P = 0.02). Conclusion Trainee involvement significantly increased EBUS duration and the dose of local anesthesia used for the procedure. Diagnostic yield was lower when a trainee was involved. Factors accounting for this difference in yield, despite adequate samples being obtained, warrant further investigation.
Collapse
|
14
|
Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study. Open Respir Med J 2017; 10:79-85. [PMID: 28144366 PMCID: PMC5220169 DOI: 10.2174/1874306401610010079] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 11/10/2016] [Accepted: 11/14/2016] [Indexed: 11/22/2022] Open
Abstract
Background: Sampling of peripheral pulmonary nodules with radial endobronchial ultrasound (p-EBUS) increases diagnostic yield of bronchoscopy. However, diagnostic yield is influenced by numerous factors. Objective: We evaluated the use of SpyGlass, a one millimeter diameter optic fiber, to obtain images of the distal mucosa and of pulmonary lesions detected with p-EBUS to determine if visual aspect of the distal mucosa was predictive of diagnosis. Methods: We prospectively recruited subjects investigated for peripheral nodules. Bronchoscopy was performed and p-EBUS was used to locate the lesion through a guide sheath. The Spyglass fiber was introduced in the sheath to obtain images of the distal bronchial mucosa. Tissue sampling was subsequently done. Results: Fifteen patients were enrolled in the study. A final diagnosis of malignancy was confirmed in 80%. All lesions could be located using p-EBUS (100%). Diagnostic sensitivity for p-EBUS was 58.3%. Distal mucosa could be imaged with SpyGlass in 14/15 patients (93.3%). Mucosal appearance was described as abnormal in 7 out of the 15 subjects. Mean SpyGlass procedure time was 6.5 minutes. No direct complication was reported. Conclusion: Spyglass can be used in combination with p-EBUS to obtain images of the distal bronchial mucosa and peripheral pulmonary nodules. More patients will be needed to confirm whether mucosal appearance can be predictive of malignancy.
Collapse
|
15
|
Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration. Chest 2016; 150:255. [DOI: 10.1016/j.chest.2016.03.063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Accepted: 03/29/2016] [Indexed: 01/12/2023] Open
|
16
|
Effect of Endobronchial Coils vs Usual Care on Exercise Tolerance in Patients With Severe Emphysema: The RENEW Randomized Clinical Trial. JAMA 2016; 315:2178-89. [PMID: 27179849 DOI: 10.1001/jama.2016.6261] [Citation(s) in RCA: 168] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
IMPORTANCE Preliminary clinical trials have demonstrated that endobronchial coils compress emphysematous lung tissue and may improve lung function, exercise tolerance, and symptoms in patients with emphysema and severe lung hyperinflation. OBJECTIVE To determine the effectiveness and safety of endobronchial coil treatment. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial conducted among 315 patients with emphysema and severe air trapping recruited from 21 North American and 5 European sites from December 2012 through November 2015. INTERVENTIONS Participants were randomly assigned to continue usual care alone (guideline based, including pulmonary rehabilitation and bronchodilators; n = 157) vs usual care plus bilateral coil treatment (n = 158) involving 2 sequential procedures 4 months apart in which 10 to 14 coils were bronchoscopically placed in a single lobe of each lung. MAIN OUTCOMES AND MEASURES The primary effectiveness outcome was difference in absolute change in 6-minute-walk distance between baseline and 12 months (minimal clinically important difference [MCID], 25 m). Secondary end points included the difference between groups in 6-minute walk distance responder rate, absolute change in quality of life using the St George's Respiratory Questionnaire (MCID, 4) and change in forced expiratory volume in the first second (FEV1; MCID, 10%). The primary safety analysis compared the proportion of participants experiencing at least 1 of 7 prespecified major complications. RESULTS Among 315 participants (mean age, 64 years; 52% women), 90% completed the 12-month follow-up. Median change in 6-minute walk distance at 12 months was 10.3 m with coil treatment vs -7.6 m with usual care, with a between-group difference of 14.6 m (Hodges-Lehmann 97.5% CI, 0.4 m to ∞; 1-sided P = .02). Improvement of at least 25 m occurred in 40.0% of patients in the coil group vs 26.9% with usual care (odds ratio, 1.8 [97.5% CI, 1.1 to ∞]; unadjusted between-group difference, 11.8% [97.5% CI, 1.0% to ∞]; 1-sided P = .01). The between-group difference in median change in FEV1 was 7.0% (97.5% CI, 3.4% to ∞; 1-sided P < .001), and the between-group St George's Respiratory Questionnaire score improved -8.9 points (97.5% CI, -∞ to -6.3 points; 1-sided P < .001), each favoring the coil group. Major complications (including pneumonia requiring hospitalization and other potentially life-threatening or fatal events) occurred in 34.8% of coil participants vs 19.1% of usual care (P = .002). Other serious adverse events including pneumonia (20% coil vs 4.5% usual care) and pneumothorax (9.7% vs 0.6%, respectively) occurred more frequently in the coil group. CONCLUSIONS AND RELEVANCE Among patients with emphysema and severe hyperinflation treated for 12 months, the use of endobronchial coils compared with usual care resulted in an improvement in median exercise tolerance that was modest and of uncertain clinical importance, with a higher likelihood of major complications. Further follow-up is needed to assess long-term effects on health outcomes. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01608490.
Collapse
|
17
|
Implantation of a Self-Expandable Metallic Y-Stent to Treat Tracheobronchial Stenosis: North American Clinical Experience. Chest 2015. [DOI: 10.1378/chest.2265622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
18
|
Impact of Fluoroscopy on the Diagnostic Yield of Radial EBUS Probe for Peripheral Pulmonary Lesions: A Randomized Trial. Chest 2015. [DOI: 10.1378/chest.2257975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
19
|
Diagnostic yield of non-guided flexible bronchoscopy for peripheral pulmonary neoplasia. Thorac Cancer 2015; 6:517-23. [PMID: 26273409 PMCID: PMC4511332 DOI: 10.1111/1759-7714.12223] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2014] [Accepted: 12/07/2014] [Indexed: 12/26/2022] Open
Abstract
Background The role of conventional bronchoscopy for peripheral pulmonary neoplasia remains controversial. We aimed to assess the diagnostic yield and the added value of non-guided bronchial aspiration, bronchoalveolar lavage (BAL), and brushing for the diagnosis of pulmonary neoplasia not visible endoscopically. Methods We retrospectively assessed 207 consecutive patients with a final diagnosis of peripheral lung malignancy who underwent bronchoscopy with non-guided aspiration, brushing, and BAL as their initial evaluation. The influence of clinical and radiological factors on diagnostic yield was assessed using univariate logistic regression analyses. Results The overall sensitivity of non-guided bronchoscopy was 25.6%, whereas sensitivities for bronchial aspiration, BAL, and brushing were 14.2%, 11.6%, and 16.5%, respectively. Younger age, larger lesion, central/intermediate distance from the hilum, presence of a bronchus sign, and higher standardized uptake value (SUV) on positron emission tomography scan were predictors of a higher diagnostic yield. Conversely, forced expiratory volume in one second, fellow implication in the procedure, and tumor histology did not influence sensitivity. The overall sensitivity of bronshoscopy was >40% for tumors >4 cm, located in the central/intermediate thirds of the lung, showing a bronchus sign, with an SUV >12 or occurring in patients <50 years of age. Conversely, the sensitivity was <10% for tumors <2 cm, located peripherally or with an SUV <4. Conclusion Neoplasia characteristics may help targeting situations in which conventional bronchoscopy could be used as the initial diagnostic procedure when advanced techniques are unavailable. However, advanced diagnostic tools should probably be proposed as the initial modality for the diagnosis of peripheral malignant lesions when available.
Collapse
|
20
|
Influence of Trainee Involvement on Procedure Characteristics and Diagnostic Yield for Linear Endobronchial Ultrasound. Chest 2014. [DOI: 10.1378/chest.1994352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
21
|
Diagnostic utility of peripheral endobronchial ultrasound with electromagnetic navigation bronchoscopy in peripheral lung nodules. Respirology 2014; 18:784-9. [PMID: 23521707 DOI: 10.1111/resp.12085] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Revised: 10/22/2012] [Accepted: 11/13/2012] [Indexed: 02/04/2023]
Abstract
BACKGROUND AND OBJECTIVE This study aimed to investigate the diagnostic utility of peripheral endobronchial ultrasound (pEBUS) followed by as-needed electromagnetic navigation bronchoscopy (ENB) for sampling peripheral lung nodules. METHODS The study was a single-arm, prospective cohort study of patients with peripheral lung nodules. Peripheral lung lesion localization was initially performed using a pEBUS probe with guide sheath. If localization failed with pEBUS alone, ENB was used to help identify the lesion. Transbronchial biopsy, bronchial brush, transbronchial needle aspiration and bronchial washings were performed. RESULTS Sixty patients were enrolled with average lesion size of 27 mm and mean pleural distance of 20 mm. Lesions were found with pEBUS alone in 75% of cases. The addition of ENB improved lesion localization to 93%. However, diagnostic yield for pEBUS alone and pEBUS with ENB were 43% and 50%, respectively. Factors predicting need for ENB use included smaller lesion size and absence of an air bronchus sign on computed tomography. CONCLUSIONS ENB improves localization of lung lesions after unsuccessful pEBUS but is often not sufficient to ensure confirmation of a specific diagnosis. Technical improvements in sampling methods could improve the diagnostic yield.
Collapse
|
22
|
Bronchoscopic treatments for emphysema. Rev Mal Respir 2011; 28:e108-14. [DOI: 10.1016/j.rmr.2009.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2009] [Accepted: 09/07/2009] [Indexed: 11/27/2022]
|
23
|
Bronchoscopic Approach to the Peripheral Lung Nodule - An Alternative Approach Using Sequential Peripheral Endobronchial Ultrasonography and Electromagnetic Navigation Bronchoscopy. Chest 2011. [DOI: 10.1378/chest.1117699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
24
|
|
25
|
Electrically switching transverse modes in high power THz quantum cascade lasers. OPTICS EXPRESS 2010; 18:10036-10048. [PMID: 20588857 DOI: 10.1364/oe.18.010036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The design and fabrication of a high power THz quantum cascade laser (QCL), with electrically controllable transverse mode is presented. The switching of the beam pattern results in dynamic beam switching using a symmetric side current injection scheme. The angular-resolved L-I curves measurements, near-field and far-field patterns and angular-resolved lasing spectra are presented. The measurement results confirm that the quasi-TM(01) transverse mode lases first and dominates the lasing operation at lower current injection, while the quasi-TM(00) mode lases at a higher threshold current density and becomes dominant at high current injection. The near-field and far-field measurements confirm that the lasing THz beam is maneuvered by 25 degrees in emission angle, when the current density changes from 1.9 kA/cm(2) to 2.3 kA/cm(2). A two-dimension (2D) current and mode calculation provides a simple model to explain the behavior of each mode under different bias conditions.
Collapse
|
26
|
Cryptogenic Hemoptysis in Chronic Obstructive Pulmonary Disease: Characteristics and Outcome. Respiration 2010; 80:387-92. [DOI: 10.1159/000264921] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2009] [Accepted: 09/22/2009] [Indexed: 11/19/2022] Open
|
27
|
|
28
|
Failure of omega-3 polyunsaturated fatty acids in prevention of migraine: a double-blind study versus placebo. Cephalalgia 2001; 21:818-22. [PMID: 11737007 DOI: 10.1046/j.1468-2982.2001.218240.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Omega-3 polyunsaturated fatty acids (OPFA) have beneficial effects on inflammatory reactions and production of cytokines. They decrease the release of 5HT by platelets and possess vasorelaxant activity. This led them to be tried in the prophylactic treatment of migraine. After 4 weeks of a single-blind placebo run-in period, patients were randomized and treated in double-blind condition by placebo or OPFA 6 g a day for 16 weeks, followed by a 4-week placebo run-out period. The intention to treat population included 196 patients. Those who received all four treatment periods included 96 patients taking OPFA and 87 taking placebo. The primary efficacy analysis was the number of migraine attacks during the last 4 weeks of treatment. During this period, the mean number of attacks was 1.20 +/- 1.40 in the OPFA group and 1.26 +/- 1.11 in the placebo group (NS). The total number of attacks during the 4-month period of the study was significantly different between groups: 7.05 in the placebo group, 5.95 in the OPFA group (P = 0.036). Mean intensity, mean duration of the attacks and rescue medication use, were not significantly different between the two groups. Except for a significant difference against OPFA for eructations, the tolerance was satisfying. Despite a run-in placebo period of 1 month, a very strong placebo effect was observed in this trial: 45% reduction of the attacks between run-in and 4-month treatment period (55% in the OPFA group, P = 0.058). Finally, this large study did not confirm two previous studies based on a small number of patients.
Collapse
|
29
|
|
30
|
|
31
|
|
32
|
Resonances in the differential electron excitation cross section of bound states of krypton in the autoionization region. ACTA ACUST UNITED AC 2001. [DOI: 10.1088/0022-3700/9/11/018] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
33
|
|
34
|
Oscillator strengths of Kr I electronic transitions measured by electron spectrometry. ACTA ACUST UNITED AC 2001. [DOI: 10.1088/0022-3700/9/14/010] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
[Treatment of migraine attacks]. PATHOLOGIE-BIOLOGIE 2000; 48:679-89. [PMID: 11072648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
The authors have presented a review of the main controlled studies on drug treatment for the management of migraine attacks: non-steroidal anti-inflammatory drugs (NSAIDs), rye ergot derivatives, and the recently commercialized triptan group of drugs. An overview is provided of their specific properties, indications and contraindications, and their respective use in the treatment of migraine headaches.
Collapse
|
36
|
3433 Oxidating stress and age-related macular degeneration (ARMD). Vision Res 1995. [DOI: 10.1016/0042-6989(95)90343-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
37
|
Phase coherence and trajectory trapping around one or two independently controllable antidots in quantum wires. PHYSICAL REVIEW. B, CONDENSED MATTER 1995; 51:11213-11216. [PMID: 9977845 DOI: 10.1103/physrevb.51.11213] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
38
|
[A case of disseminated Encephalitozoon intestinalis microsporidiosis in an AIDS patient in Nîmes]. BULLETIN DE LA SOCIETE DE PATHOLOGIE EXOTIQUE (1990) 1995; 88:229-33. [PMID: 8646012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The pathogene's role importance of the microsporidia in nature is considerable. The human being, easily in contact, presents clinical manifestations only with some of them and in a very occasional manner. The increased frequency of the immunodepression has permitted to describe recently a new protozoon, Encephalitozoon intestinalis (alias Septata intestinalis) of the family of the Glugeidae and the human illness of which it is the agent. This parasitose is interesting to be presented because of its rarity and its circulation to organs far from one another. The diagnostic has been done thanks to the only optic microscope and confirmed from its visible efficacity of one cure of albendazole. The pyrimethamine could present a relative efficiency on a relapse of the sinusitis.
Collapse
|
39
|
Design optimization of multilayer nonlinear antiresonant waveguides for blue - green surface normal second-harmonic generation. OPTICS LETTERS 1993; 18:2005. [PMID: 19829473 DOI: 10.1364/ol.18.002005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
40
|
Fluoroquinolones in the Management of Joint-Prosthesis Infection. Drugs 1993. [DOI: 10.2165/00003495-199300453-00204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
41
|
[Prescription of bromides, or how to avoid bromide salts toxicity]. Presse Med 1991; 20:1005-6. [PMID: 1829211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
|
42
|
[Bumetanide as replacement therapy in furosemide-induced vasculitis]. Presse Med 1990; 19:1504-5. [PMID: 2146658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
43
|
Pneumocystis carinii infection of bone marrow in patients with malignant lymphoma and acquired immunodeficiency syndrome. Original report of three cases. ARCHIVES OF INTERNAL MEDICINE 1990; 150:450-2. [PMID: 2302020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Pneumocystis carinii (PC) pneumonia was reported with increased frequency in patients presenting with acquired immunodeficiency syndrome (AIDS) or in patients receiving immunosuppressive chemotherapy for hemopathies. Extrapulmonary dissemination of PC is rare. In this study, three patients had PC infection of the bone marrow. Two of them presented with malignant lymphoma that had apparent immunosuppression, and the third patient presented with AIDS. In all three cases, such an infection was observed before or concomittantly with PC pneumonia. A bone marrow biopsy, bone marrow aspirate, or both can be useful, readily available tools for the diagnosis of a PC infection and especially its dissemination in patients with malignant lymphoma after intensive treatment or in patients with AIDS. The appreciation of such a dissemination may have some implications in the treatment of PC infection.
Collapse
|
44
|
[Acute necrotic-hemorrhagic pancreatitis caused by Asiatic distomiasis]. Presse Med 1986; 15:1100-1. [PMID: 2942894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
45
|
|
46
|
Abstract
The kinetics of absorption of intraperitoneally administered insulin were studied in nine uraemic insulin-dependent diabetics undergoing continuous ambulatory peritoneal dialysis (CAPD). In each of three studies 20 U of regular insulin was directly injected as a bolus into the peritoneal cavity through an indwelling Tenckhoff catheter. In two procedures the insulin injection was followed by the instillation of either 2 litres of 1.5% dextrose dialysates or 2 litres of 4.5% dextrose dialysate. In the third 20 ml of saline was used to flush the tubing. Plasma free insulin values rose more rapidly and reached significantly higher concentrations (55.6 +/- 18.8 mU/l) when the insulin had been injected into an empty peritoneal cavity than when it was followed by dialysate. These differences were observed despite the fact that most of the insulin injected was retained by the patients. Since the plasma insulin values did not differ after instillations of dialysate containing 1.5% and 4.5% dextrose, the osmolality of the dialysate seemed not to affect insulin absorption, and the dilution of the insulin probably delayed its transfer through the peritoneum. These findings suggest that insulin given intraperitoneally to patients undergoing CAPD will be most effective if it is given into an empty peritoneal cavity at least 30 minutes before the dialysate is instilled.
Collapse
|
47
|
Correlation between the nature and amount of carbohydrate in meal intake and insulin delivery by the artificial pancreas in 24 insulin-dependent diabetics. Diabetes 1981; 30:101-5. [PMID: 7009264 DOI: 10.2337/diab.30.2.101] [Citation(s) in RCA: 32] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
We have studied the effects of mixed meals and dextrose intake on blood glucose and insulin delivery by the artificial pancreas in 24 insulin-dependent diabetics. A group of 12 patients had 3 mixed meals containing at random 20, 40, and 60 g of complex carbohydrate along with protein and fat; another group of 12 diabetics, comparable in weight, age, and duration of diabetes, received at random 20, 40, and 60 g of dextrose. Dextrose ingestion led to a higher initial blood glucose increase than did the mixed meal, but the duration of blood glucose increase lasted significantly longer after the mixed meal than after the dextrose load. The areas under the curves of hyperglycemia were not significantly different. There was a high (but not linear) correlation between the total amount of insulin delivered in order to restore initial blood glucose values and the amount of CHO consumed. There was no correlation with age, body weight, duration of diabetes, nor with the nature and order of administration of the CHO load; 5.1 +/- 1.6 to 13.7 +/- 2.1 units of insulin were needed for a period of 94 +/- 11 to 132 +/- 11 min. It is suggested that some of the data obtained in this study might be useful in the programming of an open-loop insulin infusion system.
Collapse
|
48
|
[New technics of insulin adminstration: experience of the Hotel-Dieu]. JOURNEES ANNUELLES DE DIABETOLOGIE DE L'HOTEL-DIEU 1980:47-58. [PMID: 6995676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
49
|
|
50
|
Abstract
A study was performed to estimate the absorption kinetics of insulin infused subcutaneously. Four insulin-dependent diabetic subjects had their insulin pumped through a subcutaneously implanted fine polyethylene catheter at a constant rate of 5.0 +/- 0.3 ml/h but at two different insulin concentrations: 218 mU/ml between meals, and 2400 mU/ml at the start of breakfast, lunch, and dinner (lasting 20, 30, and 30 min, respectively). The amount (40 U/day) and distribution of insulin delivered was identical in the four patients in order to facilitate comparison between the subjects. No attempt was made to normalize their blood glucose during the study period. A study of the kinetics of insulin absorption was made by assaying plasma insulin levels; lack of plasma anti-insulin antibodies was verified; plasma C-peptide levels were measured and were far below values observed in the fed state in nondiabetic patients. The mean maximum insulin level reached after switching from low to high concentration insulin was observed 87 +/- 2 min after breakfast, 117 +/- 22 min after lunch, and 125 +/- 20 min after dinner. Differences observed are not significant. These values are similar to those observed after subcutaneous injection of 40 U/ml Regular insulin as a single bolus. After switching from high to low concentration, plasma insulin levels did not return to their basal values before the third or fourth hour. Subcutaneous insulin infusion could be a safe and easy way of insulin administration in an open-loop system; however, this method does not seem to be suitable for a closed-loop system.
Collapse
|