1
|
Directional Optical Coherence Tomography Imaging of Macular Pathology. Retina 2024:00006982-990000000-00635. [PMID: 38564762 DOI: 10.1097/iae.0000000000004105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 02/22/2024] [Indexed: 04/04/2024]
Abstract
PURPOSE To survey the impact of directional reflectivity on structures within optical coherence tomography (OCT) images in retinal pathology. METHODS Sets of commercial OCT images taken from multiple pupil positions were analyzed. These Directional OCT (D-OCT) sets revealed directionally reflective structures within the retina. After ensuring sufficient image quality, resulting hybrid and composite images were characterized by assessing the Henle Fiber Layer (HFL), Outer Nuclear Layer (ONL), Ellipsoid Zone (EZ), and Interdigitation Zone (IZ). Additionally, hybrid images were reviewed for novel directionally reflective pathological features. RESULTS Cross-sectional D-OCT image sets were obtained in 75 eyes of 58 subjects having a broad range of retinal pathologies. All cases showed improved visualization of the ONL/Henle fiber layer interface, and ONL thinning was therefore more apparent in several cases. The EZ and IZ also demonstrated attenuation where a geometric impact of underlying pathology affected their orientation. Misdirected photoreceptors were also noted as a consistent direction-dependent change in EZ reflectivity between regions of normal and absent EZ. CONCLUSION D-OCT enhances the understanding of retinal anatomy and pathology. This optical contrast yields more accurate identification of retinal structures and possible imaging biomarkers for photoreceptor-related pathology.
Collapse
|
2
|
Alignment, calibration, and validation of an adaptive optics scanning laser ophthalmoscope for high-resolution human foveal imaging. APPLIED OPTICS 2024; 63:730-742. [PMID: 38294386 PMCID: PMC11062499 DOI: 10.1364/ao.504283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 12/26/2023] [Indexed: 02/01/2024]
Abstract
In prior art, advances in adaptive optics scanning laser ophthalmoscope (AOSLO) technology have enabled cones in the human fovea to be resolved in healthy eyes with normal vision and low to moderate refractive errors, providing new insight into human foveal anatomy, visual perception, and retinal degenerative diseases. These high-resolution ophthalmoscopes require careful alignment of each optical subsystem to ensure diffraction-limited imaging performance, which is necessary for resolving the smallest foveal cones. This paper presents a systematic and rigorous methodology for building, aligning, calibrating, and testing an AOSLO designed for imaging the cone mosaic of the central fovea in humans with cellular resolution. This methodology uses a two-stage alignment procedure and thorough system testing to achieve diffraction-limited performance. Results from retinal imaging of healthy human subjects under 30 years of age with refractive errors of less than 3.5 diopters using either 680 nm or 840 nm light show that the system can resolve cones at the very center of the fovea, the region where the cones are smallest and most densely packed.
Collapse
|
3
|
Retraction Note: Eye tracking: empirical foundations for a minimal reporting guideline. Behav Res Methods 2024; 56:511-512. [PMID: 37973712 PMCID: PMC10794474 DOI: 10.3758/s13428-023-02285-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
|
4
|
Contributed Session II: Bringing color into focus: Dynamic accommodation responses to polychromatic stimuli. J Vis 2023; 23:76. [PMID: 38109572 DOI: 10.1167/jov.23.15.76] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023] Open
Abstract
As humans look around the environment, the crystalline lens inside the eye changes optical power to bring retinal images into focus. This visuomotor response is called accommodation. For a given accommodative state, light at only one wavelength can be in focus because the eye contains significant chromatic aberration. We examined how the visual system weights different wavelengths for focusing polychromatic stimuli, especially those with peaks at more than one wavelength. With an autorefractor, we continuously measured human accommodative responses (at 30 Hz) to stimuli comprising various mixtures of short- and long-wavelength content. In a series of trials, seven human observers viewed a three-letter word stimulus spanning 1.5° (24 arcmins per letter) against a black background on an AMOLED display for seven seconds. The optical distance of the screen was varied using a focus-adjustable lens. Halfway through the trial, the stimulus underwent a step change in optical distance (±0.75, 1.00, or 1.50 diopters). Simultaneously, the color of the stimulus changed. Accommodative responses for each subject were analyzed with nested descriptive models, including a color-free model, a weighted-averaging model, and a color-switching model. The results show that stimulus color significantly influences the dynamic accommodative response, and that long wavelengths influence the response more than short wavelengths, even when their luminance is the same.
Collapse
|
5
|
Contributed Session II: The relationship between temporal summation at detection threshold and fixational eye movements. J Vis 2023; 23:75. [PMID: 38109573 DOI: 10.1167/jov.23.15.75] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023] Open
Abstract
We studied the relationship between the threshold temporal summation of increment pulses and fixational eye-movements. Six participants completed a 2AFC increment detection task. Stimuli were 0.16 x 2.2 arcmin increments of 543 nm light presented via an AOSLO with a 60 Hz frame rate. Stimuli for temporal integration were two single frame presentations with a 16 ms (consecutive frames), 33 ms, 100 ms, or 300 ms inter-stimulus interval (ISI). Data were also collected for increments presented on a single frame. Stimuli were presented in either world-fixed coordinates (natural retinal image motion) or were stabilised on the retina. There were large differences in overall sensitivity across individuals, but the time-course of performance change with ISI was similar across participants. Thresholds for ISI=33 ms were close to performance with two consecutive frames, suggesting complete summation of light energy; whereas thresholds for ISI=300 ms were closer to the single-frame case, suggesting limited summation; and thresholds for ISI=100 ms were intermediate, suggesting residual summation. The effect of ISI on threshold was similar for stabilised stimuli and natural viewing, but there was a small trend towards lower thresholds for stabilised stimuli at short ISI and vice-versa at long ISI. We plan to present our results in the context of an ideal observer calculation that may clarify how the initial visual encoding, including temporal summation within cones, shapes performance.
Collapse
|
6
|
Poster Session I: Does stimulus image quality affect fixational eye movement characteristics? J Vis 2023; 23:43. [PMID: 38109605 DOI: 10.1167/jov.23.15.43] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023] Open
Abstract
Drift has been found to be inversely related to visual acuity (higher diffusion constants for observers with lower visual acuity; Clark et. al, 2022). However, it is not clear if this reflects long-term tuning to ocular characteristics, or a more dynamic adjustment to image quality. To test this, fixational eye movements were measured using an AOSLO and stimuli were presented through the imaging system at 30 Hz. Image quality was altered by simulating aberrations. Five participants completed a tumbling E task under three conditions: no aberration, the participant's natural aberration, and 0.25 D defocus. A 1.2 arcmin gap width E was presented as a 543 nm increment on the 840 nm imaging light for 750 ms. Conditions were randomly interleaved, and feedback was given on each trial. As expected, performance was highest with no aberration, followed by the observer's natural aberration and was worst for defocus. However, drift characteristics (bivariate contour ellipse area, BCEA, and diffusion constant) did not vary, suggesting that on a trial-to-trial basis drift was not tuned to stimulus quality. To test whether drift might be tuned over time, two participants repeated the experiment in ordered blocks of trials. There were differences in BCEA between ordered and randomised trials, but these were not consistent between participants. We will present an analysis of the differences found between individuals in terms of the optical aberrations present in their eye.
Collapse
|
7
|
Boosting 2-photon vision with adaptive optics. J Vis 2023; 23:4. [PMID: 37801322 PMCID: PMC10561787 DOI: 10.1167/jov.23.12.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Accepted: 09/05/2023] [Indexed: 10/07/2023] Open
Abstract
The 2-photon effect in vision occurs when two photons of the same wavelength are absorbed by cone photopigment in the retina and create a visual sensation matching the appearance of light close to half their wavelength. This effect is especially salient for infrared light, where humans are mostly insensitive to 1-photon isomerizations and thus any perception is dominated by 2-photon isomerizations. This phenomenon can be made more readily visible using short-pulsed lasers, which increase the likelihood of 2-photon excitation by making photon arrivals at the retina more concentrated in time. Adaptive optics provides another avenue for enhancing the 2-photon effect by focusing light more tightly at the retina, thereby increasing the spatial concentration of incident photons. This article makes three contributions. First, we demonstrate through color-matching experiments that an adaptive optics correction can provide a 25-fold increase in the luminance of the 2-photon effect-a boost equivalent to reducing pulse width by 96%. Second, we provide image-based evidence that the 2-photon effect occurs at the photoreceptor level. Third, we use our results to compute the specifications for a system that could utilize 2-photon vision and adaptive optics to image and stimulate the retina using a single infrared wavelength and reach luminance levels comparable to conventional displays.
Collapse
|
8
|
Contributed Session I: Towards General Video Percepts Cone-by-Cone. J Vis 2023; 23:8. [PMID: 37733570 DOI: 10.1167/jov.23.11.8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023] Open
Abstract
We aim to reprogram visual perception through an Adaptive Optics Scanning Laser Ophthalmoscope (AOSLO) Display, using a GPU renderer that rasterizes a target color image or video into cone-by-cone single-wavelength laser light pulses ("microdoses"). We imaged and tracked at ~ 2° eccentricity a 0.9° x 0.9° field of view of the retina in 840 nm. Stimulated in 543 nm, all resolved, spectrally classified cones receive microdoses of varying intensities. The renderer updates for each AOSLO frame (30 frames / sec) an underlying stimulation image buffer, encoding a desired color percept pattern that takes into account the cone locations, cone spectral sensitivity to the 543 nm stimulation light, and the corresponding color percept pixel values. Within one frame, the buffer gets pixelated strip-by-strip at 1 kHz into actual world-fixed microdose intensity values, each centered on a cone within that strip at that instant. The resulting frame of microdoses visually occupies the whole raster view. We showed multiple color percepts to a cone-classified subject, with logging data. The subject saw spatially-varying colors, e.g. a red box moving on a green canvas - these percepts validated the accuracy of the prototype. These initial prototyping experiments allude to the potential of presenting general percepts to a cone-classified subject, at cone-level accuracy in a fully programmable way. The technology allows us to probe neural plasticity and towards generation of novel percepts.
Collapse
|
9
|
Poster Session: Eliciting Color Percepts over Extended Fields through Cone-by-Cone Stimulation. J Vis 2023; 23:46. [PMID: 37733532 DOI: 10.1167/jov.23.11.46] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023] Open
Abstract
Purpose Human color vision is informed by the relative activations of the long-, medium-, and short-wavelength sensitive cones. We have developed a display that can produce a variety of color sensations using only a single wavelength of light, by programming the activity levels of the three cone types at population scales. Methods With an Adaptive Optics Scanning Laser Ophthalmoscope, we image the retina at 840 nm over a 0.9° x 0.9° field and track the eye's fixational motion in order to deliver discrete microdoses of 543 nm light to ~2500 individual cones per frame. Using each cone type's spectral sensitivity to 543 nm, we can recapitulate the relative activations consistent with colors that are distinct from the stimulating laser, resulting in percepts of uniform colored squares that appear stable in the world. Results Using stimulation from only 543 nm light, we can elicit color percepts ranging from green to red-orange in 2 subjects who have cone spectral types classified in a region of their retina. Additionally, we find through color matching data that the distinct color percepts are lost for intentional misdeliveries that exceed 30% of the cone diameter in both subjects. Conclusions These results demonstrate our system's ability to track the retina at high speed, stimulate with cone-level precision, and generate color percepts by directly programming the activity of the human cone mosaic. These technical capabilities provide a novel platform for studying color vision.
Collapse
|
10
|
Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway. Invest Ophthalmol Vis Sci 2023; 64:17. [PMID: 37459066 PMCID: PMC10362924 DOI: 10.1167/iovs.64.10.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/20/2023] Open
Abstract
Purpose To measure photoreceptor packing density and S-cone spatial resolution as a function of retinal eccentricity in patients with enhanced S-cone syndrome (ESCS) and to discuss the possible mechanisms supporting their supernormal S-cone acuity. Methods We used an adaptive optics scanning laser ophthalmoscope (AOSLO) to characterize photoreceptor packing. A custom non-AO display channel was used to measure L/M- and S-cone-mediated visual acuity during AOSLO imaging. Acuity measurements were obtained using a four-alternative, forced-choice, tumbling E paradigm along the temporal meridian between the fovea and 4° eccentricity in five of six patients and in seven control subjects. L/M acuity was tested by presenting long-pass-filtered optotypes on a black background, excluding wavelengths to which S-cones are sensitive. S-cone isolation was achieved using a two-color, blue-on-yellow chromatic adaptation method that was validated on three control subjects. Results Inter-cone spacing measurements revealed a near-uniform cone density profile (ranging from 0.9-1.5 arcmin spacing) throughout the macula in ESCS. For comparison, normal cone density decreases by a factor of 14 from the fovea to 6°. Cone spacing of ESCS subjects was higher than normal in the fovea and subnormal beyond 2°. Compared to the control subjects (n = 7), S-cone-mediated acuities in patients with ESCS were normal near the fovea and became increasingly supernormal with retinal eccentricity. Beyond 2°, S-cone acuities were superior to L/M-cone-mediated acuity in the ESCS cohort, a reversal of the trend observed in normal retinas. Conclusions Higher than normal parafoveal cone densities (presumably dominated by S-cones) confer better than normal S-cone-mediated acuity in ESCS subjects.
Collapse
|
11
|
Cone Structure and Function in RPGR- and USH2A-Associated Retinal Degeneration. Am J Ophthalmol 2023; 250:1-11. [PMID: 36646238 PMCID: PMC10308738 DOI: 10.1016/j.ajo.2023.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 01/08/2023] [Accepted: 01/09/2023] [Indexed: 01/15/2023]
Abstract
PURPOSE To compare cone structure and function between RPGR- and USH2A-associated retinal degeneration. DESIGN Retrospective, observational, cross-sectional study. METHODS This multicenter study included 13 eyes (9 participants) with RPGR-related X-linked retinitis pigmentosa (RPGR), 15 eyes (10 participants) with USH2A-related Usher syndrome type 2 (USH2), 16 eyes (9 participants) with USH2A-related autosomal recessive retinitis pigmentosa (ARRP), and 7 normal eyes (6 participants). Structural measures included cone spacing and density from adaptive optics scanning laser ophthalmoscopy and photoreceptor inner segment (IS), outer segment (OS), and outer nuclear layer (ONL) thickness from optical coherence tomography (OCT) images. OCT angiography images were used to study choriocapillaris flow deficit percent (CCFD). Cone function was assessed by fundus-guided microperimetry. Measures were compared at designated regions using analysis of variance with pairwise comparisons among disease groups, adjusted for disease duration and eccentricity. RESULTS OCT segmentation revealed shorter OS and IS, with reduced ONL thickness in RPGR compared to normal (OS: P < .001, IS: P = .001, ONL: P = .005), USH2 (OS: P = .01, IS: P = .03, ONL: P = .03), or ARRP (OS: P = .001, ONL: P = .03). Increased cone spacing was observed in both RPGR (P = .03) and USH2 compared with normal (P = .048). The mean CCFD in RPGR was greater than in USH2 (P = .02). Microperimetry demonstrated below-normal regional sensitivity in RPGR (P = .004), USH2 (P = .02), and ARRP (P = .009), without significant intergroup differences. CONCLUSIONS Outer retinal structure and choriocapillaris perfusion were more abnormal in RPGR- than USH2A-related retinal degenerations, whereas there were no significant differences in below-normal regional sensitivity between each rod-cone degeneration associated with variants in these 2 genes expressed at the photoreceptor-connecting cilium.
Collapse
|
12
|
It's not easy seeing green: The veridical perception of small spots. J Vis 2023; 23:2. [PMID: 37133838 PMCID: PMC10166115 DOI: 10.1167/jov.23.5.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 03/26/2023] [Indexed: 05/04/2023] Open
Abstract
When single cones are stimulated with spots of 543-nm light presented against a white background, subjects report percepts that vary between predominately red, white, and green. However, light of the same spectral composition viewed over a large field under normal viewing conditions looks invariably green and highly saturated. It remains unknown what stimulus parameters are most important for governing the color appearance in the transition between these two extreme cases. The current study varied the size, intensity and retinal motion of stimuli presented in an adaptive optics scanning laser ophthalmoscope. Stimuli were either stabilized on target locations or allowed to drift across the retina with the eye's natural motion. Increasing both stimulus size and intensity led to higher likelihoods that monochromatic spots of light were perceived as green, whereas only higher intensities led to increases in perceived saturation. The data also show an interaction between size and intensity, suggesting that the balance between magnocellular and parvocellular activation may be critical factors for color perception. Surprisingly, under the range of conditions tested, color appearance did not depend on whether stimuli were stabilized. Sequential activation of many cones does not appear to drive hue and saturation perception as effectively as simultaneous activation of many cones.
Collapse
|
13
|
Case Report: Multimodal, Longitudinal Assessment of Retinal Structure and Function following Laser Retinal Injury. Optom Vis Sci 2023; 100:281-288. [PMID: 36856552 PMCID: PMC10133204 DOI: 10.1097/opx.0000000000002004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023] Open
Abstract
SIGNIFICANCE This case report demonstrates the use of novel imaging techniques and functional tests to longitudinally evaluate retinal structure and function after laser retinal injury. The structural and functional prognosis could be predicted with clinical findings, high-resolution retinal imaging, and functional testing. PURPOSE We present a laser retinal injury case in which an adaptive optics scanning laser ophthalmoscope and adaptive optics-based psychophysics were used to examine and monitor retinal structure and function after accidental exposure to a 1-W infrared laser beam. CASE REPORT A 23-year-old patient was unwittingly exposed to a 1-W, 852-nm continuous-wave laser at work as they noticed a small central blurry spot in the right eye. An initial eye examination was done 1 day after exposure, and the right eye's acuity was 20/25 -2 . Posterior segment evaluation revealed disrupted outer retina near the right eye's fovea. Adaptive optics imaging 2 weeks after the exposure revealed a 0.50 × 0.75° elliptical area with irregular borders and abnormal cone reflectivity just below the fovea. Starting at 1-month follow-up, structural recovery was observed on optical coherence tomography (OCT). Subsequent adaptive optics imaging showed significant recovery of cone reflectivity. Importantly, adaptive optics microperimetry showed measurable detection thresholds at all affected retinal locations at 6 months. By 10 months, all sites exhibited normal sensitivities. CONCLUSIONS Retinal structure and function from laser injury can be visualized and measured with OCT, adaptive optics imaging, and psychophysics. An intact Bruch's membrane on OCT and measurable retinal sensitivity by adaptive optics microperimetry may serve as good biomarkers for retinal recovery.
Collapse
|
14
|
Evolution of adaptive optics retinal imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:1307-1338. [PMID: 36950228 PMCID: PMC10026580 DOI: 10.1364/boe.485371] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 02/02/2023] [Indexed: 05/02/2023]
Abstract
This review describes the progress that has been achieved since adaptive optics (AO) was incorporated into the ophthalmoscope a quarter of a century ago, transforming our ability to image the retina at a cellular spatial scale inside the living eye. The review starts with a comprehensive tabulation of AO papers in the field and then describes the technological advances that have occurred, notably through combining AO with other imaging modalities including confocal, fluorescence, phase contrast, and optical coherence tomography. These advances have made possible many scientific discoveries from the first maps of the topography of the trichromatic cone mosaic to exquisitely sensitive measures of optical and structural changes in photoreceptors in response to light. The future evolution of this technology is poised to offer an increasing array of tools to measure and monitor in vivo retinal structure and function with improved resolution and control.
Collapse
|
15
|
The visual benefits of correcting longitudinal and transverse chromatic aberration. J Vis 2023; 23:3. [PMID: 36729421 PMCID: PMC9907370 DOI: 10.1167/jov.23.2.3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
We describe a system-the Binocular Varichrome and Accommodation Measurement System-that can be used to measure and correct the eye's longitudinal and transverse chromatic aberration (LCA and TCA) and to perform vision tests with custom corrections. We used the system to investigate how LCA and TCA affect visual performance. Specifically, we studied the effects of LCA and TCA on visual acuity, contrast sensitivity, and chromostereopsis. LCA exhibited inter subject variability but followed expected trends compared with previous reports. TCA at the fovea was variable between individuals but with a tendency for the shift at shorter wavelengths to be more temporalward in the visual field in each eye. We found that TCA was generally greater when LCA was corrected. For visual acuity, we found that a measurable benefit was realized only with both LCA and TCA correction unless the TCA was low. For contrast sensitivity, we found that the best sensitivity to a 10-cycle/degree polychromatic grating was attained when LCA and TCA were corrected. Finally, we found that the primary cause of chromostereopsis is the TCA of the eyes.
Collapse
|
16
|
FIAT: A Device for Objective, Optical Measures of Accommodation in Phakic and Pseudophakic Eyes. Transl Vis Sci Technol 2023; 12:9. [PMID: 36607622 PMCID: PMC9836010 DOI: 10.1167/tvst.12.1.9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Purpose To present FIAT, a novel optical instrument and analysis package that is designed to elicit and optically record accommodation in human eyes. Methods FIAT employs a Shack-Hartmann wavefront sensor and a retro-illumination pupil camera that records from a single eye at video rates. It is effective at eliciting accommodation by offering the subject a full-field binocular view of an alternating distant target and a near-eye display. FIAT analysis software computes wave aberrations for each video frame over full- or subpupil sizes and computes accommodative dynamics and accommodative range. Results The system is validated by showing accurate refraction measurements in model eyes and human eyes with trial lenses. Robust accommodative responses are shown for young eyes, and a lack of accommodative response is shown for a known presbyopes. Accommodative stimulus-response curves from five phakic subjects over a range of ages show expected results. Results from two individuals with monofocal intraocular lenses are shown. Conclusions FIAT is an effective instrument for making accurate, objective measures of accommodation in phakic and pseudophakic eyes. Translational Relevance We present a device that can play an important role in the development and testing of accommodating intraocular lenses.
Collapse
|
17
|
Author Response: Radial and Tangential Retinal Magnifications as Functions of Visual Field Angle Across Spherical, Oblate, and Prolate Retinal Profiles. Transl Vis Sci Technol 2023; 12:8. [PMID: 36602813 PMCID: PMC9832725 DOI: 10.1167/tvst.12.1.8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
18
|
Enhanced S-cone Syndrome, a Mini-review. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1415:189-194. [PMID: 37440033 DOI: 10.1007/978-3-031-27681-1_28] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/14/2023]
Abstract
Enhanced S-cone Syndrome (ESCS) is an autosomal recessive inherited retinal disease mostly associated with disease-causing variants in the NR2E3 gene. During retinal development in ESCS, rod photoreceptor precursors are misdirected to form photoreceptors similar to short-wavelength cones, or S-cones. Compared to a normal human retina, patients with ESCS have no rods and significantly increased numbers of S-cones. Night blindness is the main visual symptom, and visual acuity and color vision can be normal at early disease stages. Histology of donor eyes and adaptive optics imaging revealed increased S-cone density outside of the fovea compared to normal. Visual function testing reveals absent rod function and abnormally enhanced sensitivity to short-wavelength light. Unlike most retinal degenerative diseases, ESCS results in a gain in S-cone photoreceptor function. Research involving ESCS could improve understanding of this rare retinal condition and also shed light on the role of NR2E3 expression in photoreceptor survival.
Collapse
|
19
|
Abstract
In this paper, we present a review of how the various aspects of any study using an eye tracker (such as the instrument, methodology, environment, participant, etc.) affect the quality of the recorded eye-tracking data and the obtained eye-movement and gaze measures. We take this review to represent the empirical foundation for reporting guidelines of any study involving an eye tracker. We compare this empirical foundation to five existing reporting guidelines and to a database of 207 published eye-tracking studies. We find that reporting guidelines vary substantially and do not match with actual reporting practices. We end by deriving a minimal, flexible reporting guideline based on empirical research (Section "An empirically based minimal reporting guideline").
Collapse
|
20
|
Characterizing cone spectral classification by optoretinography. BIOMEDICAL OPTICS EXPRESS 2022; 13:6574-6594. [PMID: 36589563 PMCID: PMC9774847 DOI: 10.1364/boe.473608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 05/02/2023]
Abstract
Light propagation in photoreceptor outer segments is affected by photopigment absorption and the phototransduction amplification cascade. Photopigment absorption has been studied using retinal densitometry, while recently, optoretinography (ORG) has provided an avenue to probe changes in outer segment optical path length due to phototransduction. With adaptive optics (AO), both densitometry and ORG have been used for cone spectral classification based on the differential bleaching signatures of the three cone types. Here, we characterize cone classification by ORG, implemented in an AO line-scan optical coherence tomography (OCT), and compare it against densitometry. The cone mosaics of five color normal subjects were classified using ORG showing high probability (∼0.99), low error (<0.22%), high test-retest reliability (∼97%), and short imaging durations (< 1 hour). Of these, the cone spectral assignments in two subjects were compared against AO-scanning laser opthalmoscope densitometry. High agreement (mean: 91%) was observed between the two modalities in these two subjects, with measurements conducted 6-7 years apart. Overall, ORG benefits from higher sensitivity and dynamic range to probe cone photopigments compared to densitometry, and thus provides greater fidelity for cone spectral classification.
Collapse
|
21
|
Retinal imaging using adaptive optics optical coherence tomography with fast and accurate real-time tracking. BIOMEDICAL OPTICS EXPRESS 2022; 13:5909-5925. [PMID: 36733754 PMCID: PMC9872892 DOI: 10.1364/boe.467634] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/11/2022] [Accepted: 10/04/2022] [Indexed: 05/02/2023]
Abstract
One of the main obstacles in high-resolution 3-D retinal imaging is eye motion, which causes blur and distortion artifacts that require extensive post-processing to be corrected. Here, an adaptive optics optical coherence tomography (AOOCT) system with real-time active eye motion correction is presented. Correction of ocular aberrations and of retinal motion is provided by an adaptive optics scanning laser ophthalmoscope (AOSLO) that is optically and electronically combined with the AOOCT system. We describe the system design and quantify its performance. The AOOCT system features an independent focus adjustment that allows focusing on different retinal layers while maintaining the AOSLO focus on the photoreceptor mosaic for high fidelity active motion correction. The use of a high-quality reference frame for eye tracking increases revisitation accuracy between successive imaging sessions, allowing to collect several volumes from the same area. This system enables spatially targeted retinal imaging as well as volume averaging over multiple imaging sessions with minimal correction of motion in post processing.
Collapse
|
22
|
Radial and Tangential Retinal Magnifications as Functions of Visual Field Angle Across Spherical, Oblate, and Prolate Retinal Profiles. Transl Vis Sci Technol 2022; 11:10. [PMID: 36121677 PMCID: PMC9503314 DOI: 10.1167/tvst.11.9.10] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To provide a tool for calculating radial and tangential retinal magnifications as functions of field angle and retinal shape and to articulate patterns of magnification across the retina for monocular and binocular combinations of prolate-, oblate-, and spherical-shaped retinas. Methods Formulae were derived to calculate radial and tangential retinal magnifications (mm/deg) from field angle (degrees), retinal asphericity (unitless conic constant), retinal vertex radius of curvature (mm), and nodal point position (mm). Monocular retinal magnifications were determined for eyes with prolate, spherical, and oblate retinas as functions of field angle. Bilateral differences in magnifications were examined for combinations of those eyes. Results Retinal shape substantially affects magnification profiles even for eyes with the same axial length. Greatest magnification changes across a retina and between eyes, as well as greatest increase in radial-tangential differences (distortion), occur with prolate retinas. Binocular magnification differences were smallest for oblate retinas. Nodal points anterior to the vertex center of curvature and oblate asphericity both cause field-dependent reductions in magnification relative to the fovea (barrel distortion), whereas nodal points posterior to vertex center of curvature and prolate asphericity cause the opposite (pincushion distortion). Retinal magnification differences due to eye shape are much greater than aniseikonia thresholds and chromatic differences in magnification. A spreadsheet tool implements the magnification calculations. Conclusions Local retinal magnifications as functions of field angle have substantial effects on objective applications (imaging retinal anatomy) and subjective experiences (aniseikonia) and quantify an ocular property that differs across eye shapes and refractive errors. Translational Relevance Methods are provided to customize the calculation of radial and tangential magnifications across the retina for individual eyes, which will bolster the multifactorial study of the effects of foveal and peripheral optics across eye shapes and refractive errors.
Collapse
|
23
|
Contributed Session III: The benefits of naturally moving over stabilized stimuli for acuity increase with longer presentation times. J Vis 2022. [DOI: 10.1167/jov.22.3.33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
24
|
Characterizing Fixational Eye Motion Variance Over Time as Recorded by the Tracking Scanning Laser Ophthalmoscope. Transl Vis Sci Technol 2022; 11:35. [PMID: 35201339 PMCID: PMC8883154 DOI: 10.1167/tvst.11.2.35] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). Methods We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. Results Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). Conclusions The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.
Collapse
|
25
|
Abstract
Purpose To characterize the structure and function of patches of dysflective cones in the foveal region of subjects with normal vision and no known pathology. Dysflective cones are cones that have little or no reflective properties in optical coherence tomography (OCT) or adaptive optics scanning laser ophthalmoscope (AOSLO) images yet exhibit measurable function. Methods AOSLO images were surveyed for the presence of hyporeflective cone patches, and subjects were brought back for imaging to determine the changes in the hyporeflective region. Adaptive optics microperimetry (AOMP) was used to assess the function of hyporeflective patches in four subjects to determine that they did, in fact, contain dysflective cones. AOMP utilized a stimulus size of less than 1 arcmin to measure thresholds inside and outside the hyporeflective region. Results Nineteen out of 47 individuals retrospectively reviewed had one or more regions with hyporeflective cone patches in one or both eyes. Ten subjects with hyporeflective cone patches were brought back for imaging. Seven of the 10 had resolved at follow up, and in three subjects new hyporeflective patches appeared in a different location. All AOMP-measured subjects had measurable function in the dysflective cone region. Three out of four subjects showed no difference in light sensitivity in the dysflective region compared to adjacent areas, and one subject showed a 3× reduction in sensitivity in the area. Conclusions Patches of dysflective cone have been identified in subjects with normal vision and no known pathology, and we have observed instances where dysflective cones in these subjects regain normal reflective properties.
Collapse
|
26
|
Abstract
Due to the dramatic difference in spatial resolution between the central fovea and the surrounding retinal regions, accurate fixation on important objects is critical for humans. It is known that the preferred retinal location (PRL) for fixation of healthy human observers rarely coincides with the retinal location with the highest cone density. It is not currently known, however, whether the PRL is consistent within an observer or is subject to fluctuations and, moreover, whether observers' subjective fixation location coincides with the PRL. We studied whether the PRL changes between days. We used an adaptive optics scanning laser ophthalmoscope to project a Maltese cross fixation target on an observer's retina and continuously imaged the exact retinal location of the target. We found that observers consistently use the same PRL across days, regardless of how much the PRL is displaced from the cone density peak location. We then showed observers small stimuli near the visual field location on which they fixated, and the observers judged whether or not the stimuli appeared in fixation. Observers' precision in this task approached that of fixation itself. Observers based their judgment on both the visual scene coordinates and the retinal location of the stimuli. We conclude that the PRL in a normally functioning visual system is fixed, and observers use it as a reference point in judging stimulus locations.
Collapse
|
27
|
Abstract
Human fixational eye movements are so small and precise that high-speed, accurate tools are needed to fully reveal their properties and functional roles. Where the fixated image lands on the retina and how it moves for different levels of visually demanding tasks is the subject of the current study. An Adaptive Optics Scanning Laser Ophthalmoscope (AOSLO) was used to image, track and present a variety of fixation targets (Maltese cross, disk, concentric circles, Vernier and tumbling-E letter) to healthy subjects. During these different passive (static) or active (discriminating) tasks under natural eye motion, the landing position of the target on the retina was tracked in space and time over the retinal image directly with high spatial (<1 arcmin) and temporal (960 Hz) resolution. We computed both the eye motion and the exact trajectory of the fixated target's motion over the retina. We confirmed that compared to passive tasks, active tasks elicited a partial inhibition of microsaccades, leading to longer drift periods compensated by larger corrective saccades. Consequently, the overall fixation stability during active tasks was on average 57% larger than during passive tasks. The preferred retinal locus of fixation was the same for each task and did not coincide with the location of the peak cone density.
Collapse
|
28
|
ABUNDANCE AND MULTIMODAL VISIBILITY OF SOFT DRUSEN IN EARLY AGE-RELATED MACULAR DEGENERATION: A Clinicopathologic Correlation. Retina 2021; 40:1644-1648. [PMID: 32568988 DOI: 10.1097/iae.0000000000002893] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To determine the abundance and multimodal visibility of drusen and basal linear deposit (BLinD) in early age-related macular degeneration. METHODS A 69-year-old white man was imaged by color fundus photography and red free photography, fundus autofluorescence, and optical coherence tomography. From en face images, we determined the drusen field, drusen area, and equivalent diameters of individual drusen. From high-resolution light-microscopic histology (6 months after the last clinic visit), we determined the area of drusen, BLinD, and pre-BLinD in a subretinal pigment epithelium-basal lamina lipid field. RESULTS In right and left eyes, respectively, BLinD covered 40% and 46% of the lipid field, versus 21% and 14% covered by drusen. The lipid field was covered 60% to 61% by Drusen + BLinD and 65% to 72% by BLinD + pre-BLinD. In the left eye, the drusen area on color fundus photography (0.18 mm) and red free (0.28 mm) was smaller than the drusen area on histology (1.16 mm). Among drusen confirmed by optical coherence tomography, 55.1% and 56.6% were observed on red free and fundus autofluorescence, respectively. CONCLUSION Basal linear deposit covered 1.9 and 3.4-fold more fundus area than soft drusen, silently increasing progression risk. Improved visualization of BLinD and readouts of the retinal pigment epithelium health over lipid will assist population surveillance, early detection, and trial outcome measures.
Collapse
|
29
|
Abstract
The focusing response of the human eye — accommodation — exhibits errors known as lags and leads. Lags occur when the stimulus is near and the eye appears to focus farther than the stimulus. Leads occur with far stimuli where the eye appears to focus nearer than the stimulus. We used objective and subjective measures simultaneously to determine where the eye is best focused. The objective measures were made with a wavefront sensor and an autorefractor, both of which analyze light reflected from the retina. These measures exhibited typical accommodative errors, mostly lags. The subjective measure was visual acuity, which of course depends not only on the eye's optics but also on photoreception and neural processing of the retinal image. The subjective measure revealed much smaller errors. Acuity was maximized at or very close to the distance of the accommodative stimulus. Thus, accommodation is accurate in terms of maximizing visual performance.
Collapse
|
30
|
Identification of the functional PRL for fine visual tasks. J Vis 2020. [DOI: 10.1167/jov.20.11.1406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
31
|
The optoretinogram reveals the primary steps of phototransduction in the living human eye. SCIENCE ADVANCES 2020; 6:6/37/eabc1124. [PMID: 32917686 PMCID: PMC9222118 DOI: 10.1126/sciadv.abc1124] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/24/2020] [Indexed: 05/05/2023]
Abstract
Photoreceptors initiate vision by converting photons to electrical activity. The onset of the phototransduction cascade is marked by the isomerization of photopigments upon light capture. We revealed that the onset of phototransduction is accompanied by a rapid (<5 ms), nanometer-scale electromechanical deformation in individual human cone photoreceptors. Characterizing this biophysical phenomenon associated with phototransduction in vivo was enabled by high-speed phase-resolved optical coherence tomography in a line-field configuration that allowed sufficient spatiotemporal resolution to visualize the nanometer/millisecond-scale light-induced shape change in photoreceptors. The deformation was explained as the optical manifestation of electrical activity, caused due to rapid charge displacement following isomerization, resulting in changes of electrical potential and surface tension within the photoreceptor disc membranes. These all-optical recordings of light-induced activity in the human retina constitute an optoretinogram and hold remarkable potential to reveal the biophysical correlates of neural activity in health and disease.
Collapse
|
32
|
Comparing Cone Structure and Function in RHO- and RPGR-Associated Retinitis Pigmentosa. Invest Ophthalmol Vis Sci 2020; 61:42. [PMID: 32343782 PMCID: PMC7401955 DOI: 10.1167/iovs.61.4.42] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Purpose To study cone structure and function in patients with retinitis pigmentosa (RP) owing to mutations in rhodopsin (RHO), expressed in rod outer segments, and mutations in the RP-GTPase regulator (RPGR) gene, expressed in the connecting cilium of rods and cones. Methods Four eyes of 4 patients with RHO mutations, 5 eyes of 5 patients with RPGR mutations, and 4 eyes of 4 normal subjects were studied. Cone structure was studied with confocal and split-detector adaptive optics scanning laser ophthalmoscopy (AOSLO) and spectral-domain optical coherence tomography. Retinal function was measured using a 543-nm AOSLO-mediated adaptive optics microperimetry (AOMP) stimulus. The ratio of sensitivity to cone density was compared between groups using the Wilcoxon rank-sum test. Results AOMP sensitivity/cone density in patients with RPGR mutations was significantly lower than normal (P< 0.001) and lower than patients with RHO mutations (P< 0.015), whereas patients with RHO mutations were similar to normal (P> 0.9). Conclusions Retinal sensitivity/cone density was lower in patients with RPGR mutations than normal and lower than patients with RHO mutations, perhaps because cones express RPGR and degenerate primarily, whereas cones in eyes with RHO mutations die secondary to rod degeneration. High-resolution microperimetry can reveal differences in cone degeneration in patients with different forms of RP.
Collapse
|
33
|
Abstract
A mathematical model and a possible neural mechanism are proposed to account for how fixational drift motion in the retina confers a benefit for the discrimination of high-acuity targets. We show that by simultaneously estimating object shape and eye motion, neurons in visual cortex can compute a higher quality representation of an object by averaging out non-uniformities in the retinal sampling lattice. The model proposes that this is accomplished by two separate populations of cortical neurons - one providing a representation of object shape and another representing eye position or motion - which are coupled through specific multiplicative connections. Combined with recent experimental findings, our model suggests that the visual system may utilize principles not unlike those used in computational imaging for achieving "super-resolution" via camera motion.
Collapse
|
34
|
Wide-vergence, multi-spectral adaptive optics scanning laser ophthalmoscope with diffraction-limited illumination and collection. BIOMEDICAL OPTICS EXPRESS 2020; 11:1617-1632. [PMID: 32206432 PMCID: PMC7075605 DOI: 10.1364/boe.384229] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/11/2020] [Accepted: 02/15/2020] [Indexed: 05/06/2023]
Abstract
Visualizing and assessing the function of microscopic retinal structures in the human eye is a challenging task that has been greatly facilitated by ophthalmic adaptive optics (AO). Yet, as AO imaging systems advance in functionality by employing multiple spectral channels and larger vergence ranges, achieving optimal resolution and signal-to-noise ratios (SNR) becomes difficult and is often compromised. While current-generation AO retinal imaging systems have demonstrated excellent, near diffraction-limited imaging performance over wide vergence and spectral ranges, a full theoretical and experimental analysis of an AOSLO that includes both the light delivery and collection optics has not been done, and neither has the effects of extending wavefront correction from one wavelength to imaging performance in different spectral channels. Here, we report a methodology and system design for simultaneously achieving diffraction-limited performance in both the illumination and collection paths for a wide-vergence, multi-spectral AO scanning laser ophthalmoscope (SLO) over a 1.2 diopter vergence range while correcting the wavefront in a separate wavelength. To validate the design, an AOSLO was constructed to have three imaging channels spanning different wavelength ranges (543 ± 11 nm, 680 ± 11 nm, and 840 ± 6 nm, respectively) and one near-infrared wavefront sensing channel (940 ± 5 nm). The AOSLO optics and their alignment were determined via simulations in optical and optomechanical design software and then experimentally verified by measuring the AOSLO's illumination and collection point spread functions (PSF) for each channel using a phase retrieval technique. The collection efficiency was then measured for each channel as a function of confocal pinhole size when imaging a model eye achieving near-theoretical performance. Imaging results from healthy human adult volunteers demonstrate the system's ability to resolve the foveal cone mosaic in all three imaging channels despite a wide spectral separation between the wavefront sensing and imaging channels.
Collapse
|
35
|
Abstract
The study of fixational eye motion has implications for the neural and computational underpinnings of vision. One component of fixational eye motion is tremor, a high-frequency oscillatory jitter reported to be anywhere from ∼11-60 arcseconds in amplitude. In order to isolate the effects of tremor on the retinal image directly and in the absence of optical blur, high-frequency, high-resolution eye traces were collected in six subjects from videos recorded with an adaptive optics scanning laser ophthalmoscope. Videos were acquired while subjects engaged in an active fixation task where they fixated on a tumbling E stimulus and reported changes in its orientation. Spectral analysis was conducted on periods of ocular drift, with all drifts being concatenated together after removal of saccades from the trace. The resultant amplitude spectra showed a slight deviation from the traditional 1/f nature of optical drift in the frequency range of 50-100 Hz, which is indicative of tremor. However, this deviation rarely exceeded 1 arcsecond and the consequent standard deviation of retinal image motion over the tremor band (50-100 Hz) was just over 5 arcseconds. Given such a small amplitude, it is unlikely tremor will contribute in any meaningful way to the visual percept.
Collapse
|
36
|
Cone Structure Persists Beyond Margins of Short-Wavelength Autofluorescence in Choroideremia. Invest Ophthalmol Vis Sci 2020; 60:4931-4942. [PMID: 31770433 PMCID: PMC6879190 DOI: 10.1167/iovs.19-27979] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose We studied the relationship between structure and function of the choriocapillaris (CC), retinal pigment epithelium (RPE), and photoreceptors in patients with choroideremia (CHM). Methods Six CHM patients (12 eyes) and four normal subjects (six eyes) were studied with fundus-guided microperimetry, confocal and nonconfocal adaptive optics scanning laser ophthalmoscopy (AOSLO), near-infrared and color fundus photos, short wavelength fundus autofluorescence (SW-AF), and swept-source optical coherence tomography (SS-OCT) and angiography (SS-OCTA) images. Cone spacing was represented using Z-scores (standard deviations from the mean at that eccentricity). CC flow voids were defined using a threshold of 1 SD below the normal mean. Results Cone spacing Z-scores were not significantly correlated with distance from the borders of preserved RPE, determined using either the SS-OCT or SW-AF scans. Cone spacing Z-scores were significantly correlated with CC flow voids and retinal sensitivity. Flow voids were abnormal in regions of preserved RPE and increased progressively from within -2° of the preserved area to +2° beyond the border. Visual sensitivity decreased as CC flow voids increased approaching and beyond the border of preserved structure. Conclusions In CHM, cone spacing Z-scores correlated with CC flow voids, and were negatively correlated with retinal sensitivity, suggesting cone degeneration accompanied reduced CC perfusion. Functional cones were found outside the presumed borders of preserved outer-retina/RPE as defined by SW-AF, but not outside the borders determined by SS-OCT. The use of SW-AF to identify the border of preserved structures may underestimate regions with cells that may be amenable to treatment.
Collapse
|
37
|
Cone Spacing Correlates With Retinal Thickness and Microperimetry in Patients With Inherited Retinal Degenerations. Invest Ophthalmol Vis Sci 2019; 60:1234-1243. [PMID: 30924848 PMCID: PMC6440525 DOI: 10.1167/iovs.18-25688] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine whether high-resolution retinal imaging measures of macular structure correlate with visual function over 36 months in retinal degeneration (RD) patients and normal subjects. Methods Twenty-six eyes of 16 RD patients and 16 eyes of 8 normal subjects were studied at baseline; 15 eyes (14 RD) and 11 eyes (6 normal) were studied 36 months later. Adaptive Optics Scanning Laser Ophthalmoscopy (AOSLO) was used to identify regions of interest (ROIs) with unambiguous cones at baseline to measure cone spacing. AOSLO images were aligned with spectral-domain optical coherence tomography (SD-OCT) and fundus-guided microperimetry results to correlate structure and function at the ROIs. SD-OCT images were segmented to measure inner segment (IS) and outer segment (OS) thickness. Correlations between cone spacing, IS and OS thickness and sensitivity were assessed using Spearman correlation coefficient ρ with bootstrap analyses clustered by person. Results Cone spacing (ρ = 0.57, P < 0.001) and macular sensitivity (ρ = 0.19, P = 0.14) were significantly correlated with eccentricity in patients. Controlling for eccentricity, cone spacing Z-scores were inversely correlated with IS (ρ = −0.29, P = 0.002) and OS thickness (ρ = −0.39, P < 0.001) in RD patients only, and with sensitivity in normal subjects (ρ = −0.22, P < 0.001) and RD patients (ρ = −0.38, P < 0.001). After 36 months, cone spacing increased (P < 0.001) and macular sensitivity decreased (P = 0.007) compared to baseline in RD patients. Conclusions Cone spacing increased and macular sensitivity declined significantly in RD patients over 36 months. High resolution images of cone structure correlated with retinal sensitivity, and may be appropriate outcome measures for clinical trials in RD.
Collapse
|
38
|
Human foveal cone photoreceptor topography and its dependence on eye length. eLife 2019; 8:47148. [PMID: 31348002 PMCID: PMC6660219 DOI: 10.7554/elife.47148] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 07/08/2019] [Indexed: 01/07/2023] Open
Abstract
We provide the first measures of foveal cone density as a function of axial length in living eyes and discuss the physical and visual implications of our findings. We used a new generation Adaptive Optics Scanning Laser Ophthalmoscope to image cones at and near the fovea in 28 eyes of 16 subjects. Cone density and other metrics were computed in units of visual angle and linear retinal units. The foveal cone mosaic in longer eyes is expanded at the fovea, but not in proportion to eye length. Despite retinal stretching (decrease in cones/mm2), myopes generally have a higher angular sampling density (increase in cones/deg2) in and around the fovea compared to emmetropes, offering the potential for better visual acuity. Reports of deficits in best-corrected foveal vision in myopes compared to emmetropes cannot be explained by increased spacing between photoreceptors caused by retinal stretching during myopic progression. The human eye has many different parts that enable sight. The retina is the light sensitive tissue at the back of the eye, and it contains the fovea, the region that provides the clearest vision. Light must be focused on the retina to create images, a feat achieved by the transparent parts at the front of the eye called the cornea and lens. These parts of the eye are called the optics. Between birth and adulthood, significant changes take place in the eye. Most noticeably, the distance between the optics and the fovea grows by about seven millimeters. Cells called cone photoreceptors, which provide light sensitivity, migrate and pack into the fovea. Finally, the eye’s optics adjust to maintain a sharp focus. At the same time, the brain is learning how to process inputs from the eyes to generate mental images that realistically correspond to the physical world around it. The development of the eye is fascinating in its complexity, but for more and more people, the process does not go as expected. Specifically, a growing proportion of the population has eyes that are too long. This means that, for light reflected by far away objects, the eye’s optics form an image in front of the retina instead of on it. As a result, images of distant objects cannot be seen clearly, a condition known as myopia or nearsightedness. Researchers have also discovered that nearsighted people see less clearly than those who do not use glasses, even when given a sharp image to examine at close range. It has been hypothesized that these deficits result from stretching of the retina as the eye becomes bigger. Until recently, testing this hypothesis by looking at cone photoreceptors directly in the eye was impossible. This is because the optics of all eyes have small imperfections that distort the light passing through them, including any light used to take high resolution microscopic images of the fovea. This hurdle can be overcome using adaptive optics, which means adding a deformable mirror to the instrument being used to image the eye that can adjust to correct the distortion. Wang et al. use a new generation Adaptive Optics Scanning Laser Ophthalmoscope to check the density of cones at the fovea in relation to the size of the eye. They show that although the center of the fovea has fewer cones when the eye is bigger, this effect is more than offset because the longer eye increases magnification. So, if a near-sighted person wearing contacts and someone who does not need glasses stood side-by-side admiring the full moon, the near-sighted person would most likely have more cones sampling the image and should therefore have a higher resolution view. These findings rule out reductions in the density of cone photoreceptors as the cause or effect of visual deficits associated with near-sightedness, adding to the understanding of this common condition.
Collapse
|
39
|
Abstract
The human retina contains three classes of cone photoreceptors each sensitive to different portions of the visual spectrum: long (L), medium (M) and short (S) wavelengths. Color information is computed by downstream neurons that compare relative activity across the three cone types. How cone signals are combined at a cellular scale has been more difficult to resolve. This is especially true near the fovea, where spectrally-opponent neurons in the parvocellular pathway draw excitatory input from a single cone and thus even the smallest stimulus projected through natural optics will engage multiple color-signaling neurons. We used an adaptive optics microstimulator to target individual and pairs of cones with light. Consistent with prior work, we found that color percepts elicited from individual cones were predicted by their spectral sensitivity, although there was considerable variability even between cones within the same spectral class. The appearance of spots targeted at two cones were predicted by an average of their individual activations. However, two cones of the same subclass elicited percepts that were systematically more saturated than predicted by an average. Together, these observations suggest both spectral opponency and prior experience influence the appearance of small spots.
Collapse
|
40
|
Predicting the appearance of light targeted to spectrally identified cones. J Vis 2019. [DOI: 10.1167/19.8.13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
41
|
Loss of Foveal Cone Structure Precedes Loss of Visual Acuity in Patients With Rod-Cone Degeneration. Invest Ophthalmol Vis Sci 2019; 60:3187-3196. [PMID: 31335944 PMCID: PMC6657704 DOI: 10.1167/iovs.18-26245] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Accepted: 06/13/2019] [Indexed: 11/24/2022] Open
Abstract
Purpose To assess the relationship between cone spacing and visual acuity in eyes with rod-cone degeneration (RCD) followed longitudinally. Methods High-resolution images of the retina were obtained using adaptive optics scanning laser ophthalmoscopy from 13 eyes of nine RCD patients and 13 eyes of eight healthy subjects at two sessions separated by 10 or more months (mean 765 days, range 311-1935 days). Cone spacing Z-score measured as close as possible (average <0.25°) to the preferred retinal locus was compared with visual acuity (letters read on the Early Treatment of Diabetic Retinopathy Study [ETDRS] chart and logMAR) and foveal sensitivity. Results Cone spacing was significantly correlated with ETDRS letters read (ρ = -0.47, 95%CI -0.67 to -0.24), logMAR (ρ = 0.46, 95%CI 0.24 to 0.66), and foveal sensitivity (ρ = -0.30, 95%CI -0.52 to -0.018). There was a small but significant increase in mean cone spacing Z-score during follow-up of +0.97 (95%CI 0.57 to 1.4) in RCD patients, but not in healthy eyes, and there was no significant change in any measure of visual acuity. Conclusions Cone spacing was correlated with visual acuity and foveal sensitivity. In RCD patients, cone spacing increased during follow-up, while visual acuity did not change significantly. Cone spacing Z-score may be a more sensitive measure of cone loss at the fovea than visual acuity in patients with RCD.
Collapse
|
42
|
Binocular cross-correlation analyses of the effects of high-order aberrations on the stereoacuity of eyes with keratoconus. J Vis 2019; 19:12. [PMID: 31185094 PMCID: PMC6559754 DOI: 10.1167/19.6.12] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Stereoacuity losses are induced by increased magnitudes and interocular differences in high-order aberrations (HOAs). This study used keratoconus as a model to investigate the impact of HOAs on disparity processing and stereoacuity. HOAs and stereoacuity were quantified in subjects with keratoconus (n = 21) with HOAs uncorrected (wearing spectacles) or minimized (wearing rigid gas-permeable contact lenses) and in control subjects without keratoconus (n = 5) for 6-mm pupil diameters. Disparity signal quality was estimated using metrics derived from binocular cross-correlation functions of stereo pairs convolved with point-spread functions from these HOAs. Metrics computed for all subjects were compared with stereoacuities. The effects of contrast losses and phase shifts on disparity signal quality were studied independently by manipulating the amplitude and phase components of optical transfer functions. The magnitudes, orientations, interocular relationships in magnitude, and shape of the point-spread function affected the cross-correlation metrics that determine disparity signal quality. Stereoacuity covaries strongly with cross-correlation metrics and moderately with image-quality metrics. Both phase distortions and contrast losses due to HOAs significantly influence computations of binocular disparity. HOA-induced stereoacuity reductions are attributable to disparity blur and noise from image properties that reduce the height and kurtosis of the peak stimulus disparity match of the cross-correlation. Phase distortions and contrast losses due to HOAs are both partly responsible for the greater stereoacuity losses seen with spectacles compared to rigid gas-permeable contact lenses in keratoconus.
Collapse
|
43
|
Noninvasive imaging of the tree shrew eye: Wavefront analysis and retinal imaging with correlative histology. Exp Eye Res 2019; 185:107683. [PMID: 31158381 DOI: 10.1016/j.exer.2019.05.023] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 05/21/2019] [Accepted: 05/28/2019] [Indexed: 02/08/2023]
Abstract
Tree shrews are small mammals with excellent vision and are closely related to primates. They have been used extensively as a model for studying refractive development, myopia, and central visual processing and are becoming an important model for vision research. Their cone dominant retina (∼95% cones) provides a potential avenue to create new damage/disease models of human macular pathology and to monitor progression or treatment response. To continue the development of the tree shrew as an animal model, we provide here the first measurements of higher order aberrations along with adaptive optics scanning light ophthalmoscopy (AOSLO) images of the photoreceptor mosaic in the tree shrew retina. To compare intra-animal in vivo and ex vivo cone density measurements, the AOSLO images were matched to whole-mount immunofluorescence microscopy. Analysis of the tree shrew wavefront indicated that the optics are well-matched to the sampling of the cone mosaic and is consistent with the suggestion that juvenile tree shrews are nearly emmetropic (slightly hyperopic). Compared with in vivo measurements, consistently higher cone density was measured ex vivo, likely due to tissue shrinkage during histological processing. Tree shrews also possess massive mitochondria ("megamitochondria") in their cone inner segments, providing a natural model to assess how mitochondrial size affects in vivo retinal imagery. Intra-animal in vivo and ex vivo axial distance measurements were made in the outer retina with optical coherence tomography (OCT) and transmission electron microscopy (TEM), respectively, to determine the origin of sub-cellular cone reflectivity seen on OCT. These results demonstrate that these megamitochondria create an additional hyper-reflective outer retinal reflective band in OCT images. The ability to use noninvasive retinal imaging in tree shrews supports development of this species as a model of cone disorders.
Collapse
|
44
|
Abstract
Purpose To compare cone spacing and choriocapillaris (CC) perfusion adjacent to geographic atrophy (GA) in patients with age-related macular degeneration (AMD) and age-similar normal eyes. Methods Subjects were imaged using adaptive optics scanning laser ophthalmoscopy (AOSLO), fundus autofluorescence (FAF), and swept-source optical coherence tomography angiography. The GA border was identified using FAF images; CC flow void was analyzed in 1° regions extending from the GA border. A grader masked to CC perfusion selected regions of interest (ROIs) with unambiguous cone mosaics in AOSLO images. At each ROI, cone spacing and CC flow void were converted to Z-scores (standard deviations from the mean of 12 normal eyes aged 50 to 81 years for cone spacing, and 60 normal eyes age 51 to 88 years for CC flow void). Results Excluding regions of GA and drusen, CC flow void in eight eyes of six patients with AMD was significantly greater than in four age-similar normal eyes (exact permutation test, P = 0.024). CC flow void was negatively correlated with distance from the GA margin (r = -0.35; 95% confidence interval [CI], -0.53 to -0.12). Increased cone spacing was significantly correlated with CC flow void (r = 0.33; 95% CI, 0.12 to 0.59). Cone spacing was increased in 39% of ROIs, while CC flow void was increased in 96% of ROIs. Conclusions In eyes with GA due to AMD, CC hypoperfusion was significantly correlated with, and more extensive than, cone photoreceptor loss. The results suggest that reduced CC perfusion contributes to the development of GA.
Collapse
|
45
|
Abstract
Organisms are faced with the challenge of making inferences about the physical world from incomplete incoming sensory information. One strategy to combat ambiguity in this process is to combine new information with prior experiences. We investigated the strategy of combining these information sources in color vision. Single cones in human subjects were stimulated and the associated percepts were recorded. Subjects rated each flash for brightness, hue, and saturation. Brightness ratings were proportional to stimulus intensity. Saturation was independent of intensity, but varied between cones. Hue, in contrast, was assigned in a stereotyped manner that was predicted by cone type. These experiments revealed that, near the fovea, long and middle wavelength sensitive cones produce sensations that can be reliably distinguished on the basis of hue, but not saturation or brightness. Taken together, these observations implicate the high-resolution, color-opponent parvocellular pathway in this low-level visual task.
Collapse
|
46
|
Transverse chromatic offsets with pupil displacements in the human eye: sources of variability and methods for real-time correction. BIOMEDICAL OPTICS EXPRESS 2019; 10:1691-1706. [PMID: 31061763 PMCID: PMC6484992 DOI: 10.1364/boe.10.001691] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 02/25/2019] [Accepted: 02/26/2019] [Indexed: 05/16/2023]
Abstract
Tracking SLO systems equipped to perform retinally targeted stimulus delivery typically use near-IR wavelengths for retinal imaging and eye tracking and visible wavelengths for stimulation. The lateral offsets between wavelengths caused by transverse chromatic aberration (TCA) must be carefully corrected in order to deliver targeted stimuli to the correct location on the retina. However, both the magnitude and direction of the TCA offset is dependent on the position of the eye's pupil relative to the incoming beam, and thus can change dynamically within an experimental session without proper control of the pupil position. The goals of this study were twofold: 1) To assess sources of variability in TCA alignments as a function of pupil displacements in an SLO and 2) To demonstrate a novel method for real-time correction of chromatic offsets. To summarize, we found substantial between- and within-subject variability in TCA in the presence of monochromatic aberrations. When adaptive optics was used to fully correct for monochromatic aberrations, variability both within and between observers was minimized. In a second experiment, we demonstrate that pupil tracking can be used to update stimulus delivery in the SLO in real time to correct for variability in chromatic offsets with pupil displacements.
Collapse
|
47
|
Relationship Between Foveal Cone Structure and Visual Acuity Measured With Adaptive Optics Scanning Laser Ophthalmoscopy in Retinal Degeneration. Invest Ophthalmol Vis Sci 2019; 59:3385-3393. [PMID: 30025078 PMCID: PMC6038831 DOI: 10.1167/iovs.17-23708] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Purpose To evaluate foveal function in patients with inherited retinal degenerations (IRD) by measuring visual acuity (VA) after correction of higher-order aberrations. Methods Adaptive optics scanning laser ophthalmoscopy (AOSLO) was used to image cones in 4 healthy subjects and 15 patients with IRD. The 840-nm scanning laser delivered an "E" optotype to measure AOSLO-mediated VA (AOSLO-VA). Cone spacing was measured at the preferred retinal locus by two independent graders and the percentage of cones below the average density of 47 age-similar healthy subjects was computed. Cone spacing was correlated with best-corrected VA measured with the Early Treatment of Diabetic Retinopathy Study protocol (ETDRS-VA), AOSLO-VA, and foveal sensitivity. Results ETDRS-VA significantly correlated with AOSLO-VA (ρ = 0.79, 95% confidence interval [CI] 0.5-0.9). Cone spacing correlated with AOSLO-VA (ρ = 0.54, 95% CI 0.02-0.7), and negatively correlated with ETDRS letters read (ρ = -0.64, 95% CI -0.8 to -0.2). AOSLO-VA remained ≥20/20 until cones decreased to 40.2% (CI 31.1-45.5) below normal. Similarly, ETDRS-VA remained ≥20/20 until cones were 42.0% (95% CI 36.5-46.1) below normal. Cone spacing z scores negatively correlated with foveal sensitivity (ρ = -0.79, 95% CI -0.9 to -0.4) and foveal sensitivity was ≥35 dB until cones were 43.1% (95% CI 39.3-46.6) below average. Conclusions VA and foveal cone spacing were weakly correlated until cones were reduced by 40% to 43% below normal. The relationship suggests that VA is an insensitive measure of foveal cone survival; cone spacing may be a more sensitive measure of cone loss.
Collapse
|
48
|
Abstract
Choroideremia (CHM) is associated with progressive degeneration of the retinal pigment epithelium (RPE), choriocapillaris (CC), and photoreceptors. As animal models of CHM are lacking, most information about cell survival has come from imaging affected patients. This chapter discusses a combination of imaging techniques, including fundus-guided microperimetry, confocal and non-confocal adaptive optics scanning laser ophthalmoscopy (AOSLO), fundus autofluorescence (FAF), and swept-source optical coherence tomography angiography (SS-OCTA) to analyze macular sensitivity, cone photoreceptor outer and inner segment structure, RPE structure, and CC perfusion, respectively. Combined imaging modalities such as those described here can provide sensitive measures of monitoring retinal structure and function in patients with CHM.
Collapse
|
49
|
Abstract
Retinal imaging has advanced to enable noninvasive in vivo visualization of macular photoreceptors with cellular resolution. Images of retinal structure are best interpreted in the context of visual function, but clinical measures of visual function lack resolution on the scale of individual cells. Combined with cross-sectional measures of retinal structure acquired with optical coherence tomography (OCT), macular photoreceptor function can be evaluated using visual acuity and fundus-guided microperimetry, but the resolution of these measures is limited to relatively large retinal areas. By incorporating adaptive optics correction of aberrations in light entering and exiting the pupil, individual photoreceptors can be visualized and stimulated to assess structure and function. Discrepancy between structural images and visual function can shed light on the origin of visible features and their relation to visual function. Dysflective cones, cones with abnormal waveguiding properties on confocal adaptive optics scanning laser ophthalmoscopy (AOSLO) images and measurable function, provide insight into the visual significance of features in retinal images and may facilitate identification of patients who could benefit from therapies.
Collapse
|
50
|
Versatile multi-detector scheme for adaptive optics scanning laser ophthalmoscopy. BIOMEDICAL OPTICS EXPRESS 2018; 9:5477-5488. [PMID: 30460141 PMCID: PMC6238903 DOI: 10.1364/boe.9.005477] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 09/25/2018] [Accepted: 09/28/2018] [Indexed: 05/18/2023]
Abstract
Adaptive optics scanning laser ophthalmoscopy (AOSLO) is a powerful tool for imaging the retina at high spatial and temporal resolution. In this paper, we present a multi-detector scheme for AOSLO which has two main configurations: pixel reassignment and offset aperture imaging. In this detection scheme, the single element detector of the standard AOSLO is replaced by a fiber bundle which couples the detected light into multiple detectors. The pixel reassignment configuration enables high resolution imaging with an increased light collection. The increase in signal-to-noise ratio (SNR) from this configuration can improve the accuracy of motion registration techniques. The offset aperture imaging configuration enhances the detection of multiply scattered light, which improves the contrast of retinal vasculature and inner retinal layers similar to methods such as nonconfocal split-detector imaging and multi-offset aperture imaging.
Collapse
|