1
|
Mind the gap-missing device on the shelf? Retrospective experience with 5/7 Occlutech duct Occluder. Acta Paediatr 2024; 113:812-817. [PMID: 38149770 DOI: 10.1111/apa.17082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/08/2023] [Accepted: 12/08/2023] [Indexed: 12/28/2023]
Abstract
AIM To describe our initial experience with the indications and results of the 5/7 Occlutech® duct Occluder (ODO, Occlutech International AB, Helsingborg, Sweden). A small incremental increase in occluder sizes is of utmost importance for successful outcomes, especially in smaller patients in whom protrusion of the distal disk towards the aorta should be minimised. METHODS Retrospective study of all patients undergoing PDA closure with the 5/7 ODO in three institutions since 2018. RESULTS The 5/7 ODO was used in 18 patients with median age and weight at the time of the procedure of 17.5 months (interquartile range 25th to 75th percentile 8 months- 4.4 years) and 13.6 kg (interquartile range 25th to 75th percentile 6.4-22.5 kg) respectively. All cases were successful. There were no cases of device embolisation, haemolysis, or flow disturbance of the LPA or the aorta. CONCLUSIONS This small retrospective study demonstrated an excellent outcome of transcatheter PDA closure with the 5/7 ODO. The device is a beneficial complement to the existing sizes of PDA devices, filling the gap between the 4/6 and 6/8 ODO and avoiding protrusion of a larger disk in the aortic isthmus.
Collapse
|
2
|
Implantation of atrial flow regulator devices in patients with congenital heart disease and children with severe pulmonary hypertension or cardiomyopathy-an international multicenter case series. Front Cardiovasc Med 2024; 10:1332395. [PMID: 38288053 PMCID: PMC10822980 DOI: 10.3389/fcvm.2023.1332395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 12/22/2023] [Indexed: 01/31/2024] Open
Abstract
Background The Occlutech Atrial Flow Regulator (AFR) is a self-expandable double-disc nitinol device with a central fenestration. Its use has been approved in the adult population with heart failure and described for pulmonary hypertension (PH). Only case reports and small series have been published about its use in the paediatric population and for congenital heart disease (CHD). Objectives The authors sought to investigate the feasibility, safety, and short-term follow-up of AFR implantation in patients with CHD or children with PH or cardiomyopathy. Methods This is a multicenter retrospective study involving 10 centers worldwide. Patients of any age with CHD or patients aged < 18 years with PH or cardiomyopathy needing AFR implantation were included. Results A total of 40 patients underwent AFR implantation. The median age of the population at the time of the procedure was 58.5 months (IQR: 31.5-142.5) and the median weight was 17 kg (IQR: 10-46). A total of 26 (65.0%) patients had CHD, nine (22.5%) children, a cardiomyopathy, and five (12.5%), a structurally normal heart. The implantation success rate was 100%. There were two early and one late device thrombosis. Two patients (5.0%) with dilated cardiomyopathy on extracorporeal membrane oxygenator (ECMO) died during the hospital stay. At a median follow-up of 330 days (IQR: 125-593), 37 (92.5%) patients were alive. At follow-up, 20 patients improved their New York Heart Association (NYHA) class, 12 patients did not change their NYHA class, and one patient with idiopathic PH worsened. Conclusions AFR implantation in patients with CHD and children with severe PH or cardiomyopathy is promising and seems to have beneficial effects at short-term follow-up.
Collapse
|
3
|
The Transcatheter Closure of Patent Ductus Arteriosus in Extremely Low-Birth-Weight Infants: Technique and Results. J Cardiovasc Dev Dis 2023; 10:476. [PMID: 38132644 PMCID: PMC10744056 DOI: 10.3390/jcdd10120476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/22/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023] Open
Abstract
Persistent patent ductus arteriosus is a very common condition in preterm infants. Although there is no management agreed by consensus, despite numerous randomized controlled trials, hemodynamically significant patent ductus arteriosus increases morbidity and mortality in these vulnerable patients. Medical treatment is usually offered as first-line therapy, although it carries a limited success rate and potential severe adverse events. In recent years, transcatheter patent ductus arteriosus closure has fast developed and become widely accepted as a safe and efficient alternative to surgical ductal ligation in extremely low birth weight infants >700 g, using most often the dedicated Amplatzer Piccolo Occluder device. This article aims to provide an appraisal of the patients' selection process, and a step-by-step description of the procedure as well as a comprehensive review of its outcomes.
Collapse
|
4
|
Segmental and global longitudinal strain differences between Kawasaki disease and multi-system inflammatory syndrome in children. Cardiol Young 2023; 33:1177-1183. [PMID: 35919031 DOI: 10.1017/s1047951122002414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Multi-system inflammatory syndrome in children and Kawasaki disease have overlapping clinical features but comparative echocardiographic studies are lacking. METHODS We reviewed echocardiography findings of all multi-system inflammatory syndrome cases between 1st April and 31st July, 2020 and typical Kawasaki disease patients with coronary arteries abnormalities consecutively followed between 1st October, 2016 and June 30th, 2019. RESULTS We included 40 multi-system inflammatory syndrome children (25 males, 62.5%) and 45 Kawasaki disease patients (31 males, 68.9%) at a mean age of 6.4 years old and 8 years old, respectively. Four out of 40 multi-system inflammatory syndrome children had coronary arteries abnormalities. Left ventricle ejection fraction was normal in both groups. Global longitudinal strain was normal although Kawasaki disease group had significantly lower values (-20.0 versus -21.7%; p = 0.02). Basal segments were the most affected in Kawasaki disease patients with significant differences in the basal anterior, anterolateral, and anteroseptal strain: -18.2 versus -23.0% (p = 0.002), -16.7 versus -22.0% (p < 0.001), -16.7 versus -19.5% (p = 0.034), respectively. The basal anterolateral and anteroseptal segments in Kawasaki disease patients were the only ones with an absolute reduction of longitudinal strain (-16.7% both) consistent with the greater left main coronary involvement in this cohort. CONCLUSIONS Our findings are consistent with the transient cardiac involvement in multi-system inflammatory syndrome, as opposed to the subtle and chronic myocardial involvement in Kawasaki disease children with coronary arteries abnormalities. We speculate that the mechanism of cardiac impairment in the few multi-system inflammatory syndrome children with reduced global longitudinal strain is not related to coronary arteries abnormalities.
Collapse
|
5
|
Characterization of cardiac involvement in children with LMNA-related muscular dystrophy. Front Cell Dev Biol 2023; 11:1142937. [PMID: 36968203 PMCID: PMC10036759 DOI: 10.3389/fcell.2023.1142937] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 02/27/2023] [Indexed: 03/12/2023] Open
Abstract
Introduction: LMNA-related muscular dystrophy is a rare entity that produce "laminopathies" such as Emery-Dreifuss muscular dystrophy (EDMD), limb-girdle muscular dystrophy type 1B (LGMD1B), and LMNA-related congenital muscular dystrophy (L-CMD). Heart failure, malignant arrhythmias, and sudden death may occur. No consensus exists on cardiovascular management in pediatric laminopathies. The aim was to perform an exhaustive cardiologic follow-up in pediatric patients diagnosed with LMNA-related muscular dystrophy. Methods: Baseline cardiac work-up consisted of clinical assessment, transthoracic Doppler echocardiography, 12-lead electrocardiogram, electrophysiological study, and implantation of a long-term implantable cardiac loop recorder (ILR). Results: We enrolled twenty-eight pediatric patients diagnosed with EDMD (13 patients), L-CMD (11 patients), LGMD1B (2 patients), and LMNA-related mild weakness (2 patients). Follow-up showed dilated cardiomyopathy (DCM) in six patients and malignant arrhythmias in five (four concomitant with DCM) detected by the ILR that required implantable cardioverter defibrillator (ICD) implantation. Malignant arrhythmias were detected in 20% of our cohort and early-onset EDMD showed worse cardiac prognosis. Discussion: Patients diagnosed with early-onset EDMD are at higher risk of DCM, while potentially life-threatening arrhythmias without DCM appear earlier in L-CMD patients. Early onset neurologic symptoms could be related with worse cardiac prognosis. Specific clinical guidelines for children are needed to prevent sudden death.
Collapse
|
6
|
Feasibility, safety, and efficacy of Atrial Flow Regulator in children under 10 kg. Catheter Cardiovasc Interv 2023; 101:396-400. [PMID: 36617379 DOI: 10.1002/ccd.30536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 12/15/2022] [Accepted: 12/24/2022] [Indexed: 01/09/2023]
Abstract
INTRODUCTION The Atrial Flow Regulator (AFR) is a new self-expandable percutaneous-delivered fenestrated device providing an interatrial shunt. Its use in pediatric population has been reported in failing Fontan, pulmonary hypertension, or in patients with cardiomyopathy and venoarterial extracorporeal membrane oxygenator (ECMO) support. Its use in small children under 10 kg has not been reported. METHODS We report the initial single center experience of the AFR implantation in children below 10 kg. RESULTS Four children underwent AFR implantation. Patients' age and weight ranged between 9 and 22 months and 5-8.7 kgs. Indications were to unload the left atrium during ECMO support for end-stage cardiomyopathy and to enlarge a restrictive interatrial shunt in two other patients with complex congenital heart diseases. Devices implanted were AFR-6 and AFR-8. Delivery sheaths used via venous femoral access were undersized and ranged from 9 to 11 Fr. Devices were successfully implanted and provided unrestrictive interatrial shunt in all cases. One child developed a nonocclusive thrombus in the inferior vena cava which resolved within 1 month. Clinical improvement and femoral vein patency were observed in all cases. CONCLUSION AFR implantation is feasible in selected children under 10 kg. The AFR can be safely deployed through sheaths that are 1-2 Fr smaller than the recommended manufacturer size. More studies are needed to confirm safety and efficacy of the device in selected pediatric patients.
Collapse
|
7
|
Pathogenesis, immunology, and immune-targeted management of the multisystem inflammatory syndrome in children (MIS-C) or pediatric inflammatory multisystem syndrome (PIMS): EAACI Position Paper. Pediatr Allergy Immunol 2023; 34:e13900. [PMID: 36705045 DOI: 10.1111/pai.13900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Accepted: 12/05/2022] [Indexed: 01/06/2023]
Abstract
Multisystem inflammatory syndrome in children (MIS-C) is a rare, but severe complication of coronavirus disease 2019 (COVID-19). It develops approximately 4 weeks after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and involves hyperinflammation with multisystem injury, commonly progressing to shock. The exact pathomechanism of MIS-C is not known, but immunological dysregulation leading to cytokine storm plays a central role. In response to the emergence of MIS-C, the European Academy of Allergy and Clinical Immunology (EAACI) established a task force (TF) within the Immunology Section in May 2021. With the use of an online Delphi process, TF formulated clinical statements regarding immunological background of MIS-C, diagnosis, treatment, follow-up, and the role of COVID-19 vaccinations. MIS-C case definition is broad, and diagnosis is made based on clinical presentation. The immunological mechanism leading to MIS-C is unclear and depends on activating multiple pathways leading to hyperinflammation. Current management of MIS-C relies on supportive care in combination with immunosuppressive and/or immunomodulatory agents. The most frequently used agents are systemic steroids and intravenous immunoglobulin. Despite good overall short-term outcome, MIS-C patients should be followed-up at regular intervals after discharge, focusing on cardiac disease, organ damage, and inflammatory activity. COVID-19 vaccination is a safe and effective measure to prevent MIS-C. In anticipation of further research, we propose a convenient and clinically practical algorithm for managing MIS-C developed by the Immunology Section of the EAACI.
Collapse
|
8
|
Transcatheter closure of large perimembranous ventricular septal defects with inlet to outlet extension with the Amplatzer Vascular Plug-II. Cardiol Young 2022; 33:1-5. [PMID: 36468549 DOI: 10.1017/s1047951122003407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Transcatheter closure of perimembranous ventricular septal defect is an alternative to surgery in selected small to medium defects with a reasonable distance between the defect and the aortic or tricuspid valves. Surgical closure is generally preferred for large defects with an inlet to outlet extension, aortic malalignment, or deficient aortic rim. We report two successful cases of percutaneous closure of large perimembranous ventricular septal defects with inlet to outlet extension using an Amplatzer Vascular Plug-II via a retrograde approach. Transcatheter closure of large perimembranous ventricular septal defect with inlet to outlet extension is feasible and facilitated by the characteristics of the Amplatzer Vascular Plug-II device and the specific implantation technique.
Collapse
|
9
|
Vicarious excretion of contrast material in a neonate. Arch Dis Child Fetal Neonatal Ed 2022; 107:335. [PMID: 33514632 DOI: 10.1136/archdischild-2020-321302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 01/06/2021] [Accepted: 01/10/2021] [Indexed: 11/03/2022]
|
10
|
Transcatheter closure of tubular patent ductus arteriosus using muscular ventricular septal defect devices in infants and small children with congestive heart failure. Arch Cardiovasc Dis 2022; 115:134-141. [DOI: 10.1016/j.acvd.2022.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 01/12/2022] [Accepted: 01/13/2022] [Indexed: 11/29/2022]
|
11
|
Outcome After Transcatheter Pulmonary Valve Replacement: Are We Focusing on the Long Term Now? J Am Coll Cardiol 2022; 79:33-34. [PMID: 34991786 DOI: 10.1016/j.jacc.2021.10.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 10/18/2021] [Indexed: 11/18/2022]
|
12
|
Myocardial deformation assessed by CMR in children after multisystem inflammatory syndrome (MIS-C). Int J Cardiol 2022; 346:105-106. [PMID: 34798209 DOI: 10.1016/j.ijcard.2021.11.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/24/2021] [Accepted: 11/15/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Short-term sequelae of Multisystem Inflammatory Syndrome in Children (MIS-C), recently published by our institution, showed rapid improvement of the cardiac abnormalities within a few weeks after the onset of the disease. However, subtle residual abnormalities, affecting mainly the myocardial interstitium, were shown in some of the patients. The current study aimed to assess myocardial deformation with CMR shortly after MIS-C. METHODS Sixty children were included into the study; 30 following MIS-C (onset-to-scan mean 27 days, SD 11) and 30 controls. Strain values were compared between patients and controls and additionally to published paediatric normal CMR values. U-Mann Whitney test was used for comparison of the myocardial deformation between patients and controls. RESULTS Median age of the patients was 9.0 years (range 0.99-14.4) and controls 9.8 years (range 4.7-14.9). All conventional CMR parameters in patients were in normal range. Strain values were significantly lower in patients than in controls. When compared to published centile graphs, radial and circumferential global strain was within 2.5th and 97.5th centile in all patients. Eleven patients had global longitudinal strain between 2.5th centile and 50th centile, 1 patient was below 2.5th centile and all the others above 50th centile. Only 3 controls had global longitudinal strain between 2.5th centile and 50th centile, all other had higher strain. CONCLUSIONS This study demonstrates that myocardial deformation indices measured by CMR are within normal range in the vast majority of the patients within a few weeks after the onset of MIS-C. However, when compared to healthy controls, all strain parameters were lower in patients.
Collapse
|
13
|
Transcatheter Closure of a Secundum Atrial Septal Defect with Deficient Aortic Rim Through the Left Internal Jugular Vein in a Child with Situs Inversus and Interrupted Inferior Vena Cava: Device's Choice Matters. Pediatr Cardiol 2021; 42:1879-1881. [PMID: 34561725 DOI: 10.1007/s00246-021-02708-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Accepted: 08/17/2021] [Indexed: 11/30/2022]
Abstract
Percutaneous closure of secundum atrial septal defect (sASD) in children with interrupted inferior vena cava is challenging, especially in case of deficient aortic rim. Trans-jugular access is generally preferred in this scenario. Patients with situs inversus and sASD also carry technical difficulties for transcatheter closure because of the orientation of the atrial septum. We report a successful case of percutaneous closure of a sASD with deficient aortic rim using an occlutech figulla flex II ASD device through the left internal jugular vein in a child with situs inversus, dextrocardia, and interrupted IVC. This case was facilitated by the absence of left-sided hub of the Occlutech device to provide stable opening of the device into the left atrium, whereas the ball-connection of the delivery system allowed an angle of almost 180 degrees between the device and the atrial septum.
Collapse
|
14
|
Case report of a Gore-Tex TCPC conduit dissection causing severe stenosis. Eur Heart J Case Rep 2021; 5:ytab377. [PMID: 34746637 PMCID: PMC8567081 DOI: 10.1093/ehjcr/ytab377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/07/2021] [Accepted: 09/14/2021] [Indexed: 11/13/2022]
Abstract
Background The patient is a 15-year-old male with situs inversus, dextrocardia, bilateral superior caval veins, atrioventricular discordance with a single outlet, large perimembranous ventricular septal defect, aortic override, pulmonary atresia, and right aortic arch. The complex anatomy with a Ventricular Septal Defect (VSD) distant from the aorta (unsuitable for baffling to the aorta) meant he was unsuitable for biventricular repair and proceeded down a univentricular palliation pathway. Case summary Post-total cavopulmonary connection his clinical course was uneventful until the age of 5 when he developed fatigability with desaturation. An accessory hepatic vein was surgically banded with improved saturations and exercise tolerance. At the age of 15, cardiovascular magnetic resonance (CMR) was performed to investigate borderline saturations and as workup for transition to adult services. Cardiovascular magnetic resonance and cardiac computed tomography (CT) imaging demonstrated an eccentric thrombus causing stenosis of the extracardiac conduit and a thrombus outside of the lumen contained by the thin outer membrane of the Gore-Tex conduit. Collateralization suggested this was longstanding. Cardiac catheterization demonstrated a 4 mm × 6 mm stenosis at the junction of the conduit with the pulmonary arteries. The region was successfully balloon dilated and stented with a 34 mm-long Cheatham Platinum stent, with no complications. Discussion To date, this is the first documented case of a dissecting thrombus of a Gore-Tex graft in the literature. This case emphasizes the need for anticoagulation and serial cross-sectional imaging (CT or CMR) in Fontan patients with prosthetic grafts throughout a patients’ lifetime.
Collapse
|
15
|
The Cheatham-Platinum 10-zig: First stent dedicated for adult congenital interventions? INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE 2021. [DOI: 10.1016/j.ijcchd.2021.100125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
16
|
Short-Term sequelae of Multisystem Inflammatory Syndrome in Children Assessed by CMR. JACC Cardiovasc Imaging 2021; 14:1666-1667. [PMID: 33744139 DOI: 10.1016/j.jcmg.2021.01.035] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 01/14/2021] [Accepted: 01/27/2021] [Indexed: 11/24/2022]
|
17
|
Segmental and global longitudinal strain differences between children with paediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 pandemic and Kawasaki disease. Eur Heart J Cardiovasc Imaging 2021. [PMCID: PMC7929042 DOI: 10.1093/ehjci/jeaa356.186] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Funding Acknowledgements Type of funding sources: None. Introduction The paediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 (PIMS-TS) and Kawasaki disease (KD) have overlapping features. This study aimed to describe the strain segmental analysis among both entities. Methods Retrospective review of strain segmental analysis within 4 weeks of presentation of symptoms among children diagnosed with PIMS-TS between April and June 2020 and a historic cohort of typical KD from the Royal Brompton Hospital, London. Results We included 33 PIMS-TS patients (23 males, 69.7%) at a mean age of 8 ± 4,9 years old and 45 KD patients (31 males, 68,9%) at a mean age of 5,8 ± 4,5 years old. PIMS-TS patients were older at presentation (p = 0.038). Left ventricle ejection fraction (LVEF) was normal in both groups (63,3% vs 63,5%; p= 0,89), 4/33 PIMS-TS children (12,1%) had coronary arteries abnormalities (CAA), whereas 100% of KD cohort had CAA. Both groups had a normal global longitudinal strain (GLS),but in PIMS-TS it was significantly reduced compared to the KD group (-20% vs -22%; p = 0,008). Basal segments were the most affected in PIMS-TS with significant difference in the basal anterior and anterolateral strain compared to KD (respectively -18,2% vs -23,4%; p < 0,001 and - 16,7% vs -22,7%; p < 0,001). PIMS-TS had a greater anterior, anterolateral and posterior segments involvement with a significant reduction in the anterolateral mid-wall longitudinal strain (-18,3% vs -22%; p = 0,002). Apical segments were less involved, with significant difference only in the septal and inferior apical strain (respectively p = 0.001 and p = 0,032). Conclusions These preliminary data showed that after 4 weeks from the onset of symptoms, all PIMS-TS patients had a normal LVEF but they had a significant reduction in GLS and different segmental involvement compared to KD cohort. We hypothesize that these findings may be related to direct myocardial damage in PIMS-TS rather than caused by coronaries perfusion abnormalities. Abstract Figure. Bull"s eye ![]()
Collapse
|
18
|
Multisystem Inflammatory Syndrome in Children: An International Survey. Pediatrics 2021; 147:peds.2020-024554. [PMID: 33234669 DOI: 10.1542/peds.2020-024554] [Citation(s) in RCA: 90] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/19/2020] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To describe presentation, hospital course, and predictors of bad outcome in multisystem inflammatory syndrome in children (MIS-C). METHODS Retrospective data review of a case series of children meeting the published definition for MIS-C who were discharged or died between March 1, 2020, and June 15, 2020, from 33 participating European, Asian, and American hospitals. Data were collected through a Web-based survey and included clinical, laboratory, electrocardiographic, and echocardiographic findings and treatment management. RESULTS We included 183 patients with MIS-C: male sex, 109 (59.6%); mean age 7.0 ± 4.7 years; Black race, 56 (30.6%); obesity, 48 (26.2%). Overall, 114 of 183 (62.3%) had evidence of severe acute respiratory syndrome coronavirus 2 infection. All presented with fever, 117 of 183 (63.9%) with gastrointestinal symptoms, and 79 of 183 (43.2%) with shock, which was associated with Black race, higher inflammation, and imaging abnormalities. Twenty-seven patients (14.7%) fulfilled criteria for Kawasaki disease. These patients were younger and had no shock and fewer gastrointestinal, cardiorespiratory, and neurologic symptoms. The remaining 77 patients (49.3%) had mainly fever and inflammation. Inotropic support, mechanical ventilation, and extracorporeal membrane oxygenation were indicated in 72 (39.3%), 43 (23.5%), and 4 (2.2%) patients, respectively. A shorter duration of symptoms before admission was found to be associated with poor patient outcome and for extracorporeal membrane oxygenation and/or death, with 72.3% (95% confidence interval: 0.56-0.90; P = .006) increased risk per day reduction and 63.3% (95% confidence interval: 0.47-0.82; P < .0001) increased risk per day reduction respectively. CONCLUSIONS In this case series, children with MIS-C presented with a wide clinical spectrum, including Kawasaki disease-like, life-threatening shock and milder forms with mainly fever and inflammation. A shorter duration of symptoms before admission was associated with a worse outcome.
Collapse
|
19
|
Implantation of an Atrial Flow Regulator in a Child on Venoarterial Extracorporeal Membrane Oxygenator as a Bridge to Heart Transplant: A Case Report. J Card Fail 2020; 27:364-367. [PMID: 33242607 DOI: 10.1016/j.cardfail.2020.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Revised: 10/21/2020] [Accepted: 11/16/2020] [Indexed: 11/19/2022]
Abstract
BACKGROUND Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization. CASE PRESENTATION We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted. CONCLUSIONS This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.
Collapse
|
20
|
Abstract
Background During the SARS-CoV2 pandemic, there has been increase in hyperinflammatory presentation in previously healthy children with a variety of cardiac manifestations. Our objective is to describe the cardiac manifestations found in an international cohort of 55 pediatric cases with multi-system inflammatory syndrome (MIS-C) during the SARS-CoV2 pandemic. Methods and Results We reviewed data on previously healthy pediatric patients (≤18 years) with structurally normal hearts who presented at hospitals in the United States, United Kingdom, Spain and Pakistan with MIS-C and had consultation with a pediatric cardiologist. Data collected included demographics, clinical presentation, laboratory values, electrocardiographic abnormalities, echocardiographic findings and initial therapies. A total of 55 patients presented with MIS-C. Thirty-five patients (64%) had evidence of decreased left ventricular function, 17 (31%) had valvulitis, 12 (22%) with pericardial effusion and 11 (20%) with coronary abnormalities. Twenty-seven (49%) required ICU admission and 24 (44%) had evidence of shock. Eleven patients (20%) fulfilled complete Kawasaki disease criteria and had lower NT pro-BNP, D-dimer and ferritin levels compared with those who did not fulfill criteria. Electrophysiologic abnormalities occurred in 6 patients and included complete atrioventricular (AV) block, transient AV block and ventricular tachycardia. Conclusions We describe the first international cohort of pediatric patients with MIS-C during the SARS-CoV2 pandemic with a range of cardiac manifestations. This paper brings awareness and alertness to the global medical community to recognize these children during the pandemic and understand the need for early cardiology evaluation and follow-up.
Collapse
|
21
|
More than 3 decades quest for the ideal device to close ventricular septal defects. Int J Cardiol 2020; 310:64-66. [PMID: 32331907 DOI: 10.1016/j.ijcard.2020.04.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 04/03/2020] [Indexed: 11/17/2022]
|
22
|
Transcatheter Closure of Patent Ductus Arteriosus in Infants With Weight Under 1,500 Grams. Front Pediatr 2020; 8:558256. [PMID: 33072674 PMCID: PMC7536298 DOI: 10.3389/fped.2020.558256] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 08/24/2020] [Indexed: 11/23/2022] Open
Abstract
Persistent patent ductus arteriosus (PDA) is very common in preterm infants, especially in extremely preterm infants. Despite significant advances in management of these vulnerable infants, there has been no consensus on management of PDA-when should we treat, who should we treat, how should we treat and in fact there is no agreement on how we should define a hemodynamically significant PDA. Medical management with non-steroidal anti-inflammatory drugs (NSAIDs) remains the first line of therapy with moderate success rate in closing the PDA. Paracetamol has been reported to be a safe and equally effective medical therapy for closure of PDA. However, additional studies on its long-term safety and efficacy in extremely low birth weight infants are needed before paracetamol can be recommended as standard treatment for a PDA in preterm infants. Surgical ligation of PDA is not without an increased risk of mortality and co-morbidities. Recently, there has been a significant interest in percutaneous transcatheter closure of PDA in preterm infants, including extremely low birth weight infants. Transcatheter PDA closure in preterm ELBW infants is technically feasible with high PDA occlusion success rates and acceptable complication rates as compared to surgical ligation. Many centers have reported promising early- and mid-term follow-up results. However, they need to be further tested in the prospective well-designed studies and randomized controlled trials comparing the results and outcomes of this technique with current treatment strategies including medical treatment before they can be used as the new standard of care for PDA closure in extremely low birth weight infants.
Collapse
|
23
|
Cone reconstruction is feasible in babies under 2 kg of weight. Interact Cardiovasc Thorac Surg 2019; 29:652-653. [PMID: 31161220 DOI: 10.1093/icvts/ivz134] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 04/24/2019] [Accepted: 05/04/2019] [Indexed: 11/15/2022] Open
Abstract
Symptomatic neonates with Ebstein anomaly present with intractable heart failure. We present the first successful cone reconstruction in an ex 30 + 4-week premature below 2 kg with a favourable outcome.
Collapse
|
24
|
Transapical Mitral Melody Valve-in-Valve Implantation in a Child: An Interesting Alternative for Failing Melody Valve. JACC Cardiovasc Interv 2019; 12:e137-e138. [PMID: 31377271 DOI: 10.1016/j.jcin.2019.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 05/23/2019] [Accepted: 06/04/2019] [Indexed: 11/29/2022]
|
25
|
Umbilical artery catheter, aortic dissection, carotid cannulation, and pseudoaneurysm in a neonate: A tale of propagating pathology. Ann Pediatr Cardiol 2019; 13:87-90. [PMID: 32030043 PMCID: PMC6979014 DOI: 10.4103/apc.apc_67_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 06/01/2019] [Indexed: 11/04/2022] Open
Abstract
Arterial dissections are uncommon in neonates. Complications include thrombosis, bleeding, dissection, aneurysm and pseudoaneurysm. We report an unusual case of multisite pathology (dissection and pseudoaneurysm) following common vascular interventions. A term neonate with antenatal diagnosis of congenital heart block secondary to maternal lupus deteriorated clinically at 5 days of life. He was found to have an abdominal aortic thrombus secondary to abdominal aortic dissection, following umbilical arterial catheter placement. Attempted percutaneous treatment was complicated by dissection of the left common carotid artery and formation of a large pseudoaneurysm. Neonatal lupus is associated with weakened vessel wall which may be vulnerable to injury from line placement and endovascular interventions. Various options are available to manage arterial dissection, thrombus, and pseudoaneurysm, but consequences of these options need to be carefully weighed to minimize further complications.
Collapse
|
26
|
Transcatheter closure of a large para-annular leak using a vascular plug following Cone repair of the tricuspid valve. Eur Heart J Cardiovasc Imaging 2019; 20:369. [PMID: 30629154 DOI: 10.1093/ehjci/jey198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
27
|
The Role of Echocardiography in Neonates and Pediatric Patients on Extracorporeal Membrane Oxygenation. Front Pediatr 2018; 6:297. [PMID: 30416991 PMCID: PMC6212474 DOI: 10.3389/fped.2018.00297] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 09/21/2018] [Indexed: 11/13/2022] Open
Abstract
Indications for extracorporeal membrane oxygenation (ECMO) and extracorporeal cardiopulmonary resuscitation (ECPR) are expanding, and echocardiography is a tool of utmost importance to assess safety, effectiveness and readiness for circuit initiation and separation. Echocardiography is key to anticipating complications and improving outcomes. Understanding the patient's as well as the ECMO circuit's anatomy and physiology is crucial prior to any ECMO echocardiographic evaluation. It is also vital to acknowledge that the utility of echocardiography in ECMO patients is not limited to the evaluation of cardiac function, and that clinical decisions should not be made exclusively upon echocardiographic findings. Though echocardiography has specific indications and applications, it also has limitations, characterized as: prior to and during cannulation, throughout the ECMO run, upon separation and after separation from the circuit. The use of specific and consistent echocardiographic protocols for patients on ECMO is recommended.
Collapse
|
28
|
Mannose-binding lectin-deficient genotypes as a risk factor of pneumococcal meningitis in infants. PLoS One 2017; 12:e0178377. [PMID: 28562692 PMCID: PMC5451051 DOI: 10.1371/journal.pone.0178377] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2017] [Accepted: 05/11/2017] [Indexed: 12/24/2022] Open
Abstract
Objectives The objective of this study was to evaluate to evaluate the role of mannose-binding-lectin deficient genotypes in pneumococcal meningitis (PM) in children. Methods We performed a 16-year retrospective study (January 2001 to March 2016) including patients ≤ 18 years with PM. Variables including attack rate of pneumococcal serotype (high or low invasive capacity) and MBL2 genotypes associated with low serum MBL levels were recorded. Results Forty-eight patients were included in the study. Median age was 18.5 months and 17/48 episodes (35.4%) occurred in children ≤ 12 months old. Serotypes with high-invasive disease potential were identified in 15/48 episodes (31.2%). MBL2 deficient genotypes accounted for 18.8% (9/48). Children ≤ 12 months old had a 7-fold risk (95% CI: 1.6–29.9; p < 0.01) of having a MBL2 deficient genotype in comparison to those > 12 months old. A sub-analysis of patients by age group revealed significant proportions of carriers of MBL2 deficient genotypes among those ≤ 12 months old with PM caused by opportunistic serotypes (54.5%), admitted to the PICU (Pediatric Intensive Care Unit) (46.7%) and of White ethnicity (35.7%). These proportions were significantly higher than in older children (all p<0.05). Conclusions Our results suggest that differences in MBL2 genotype in children ≤12 months old affects susceptibility to PM, and it may have an important role in the episodes caused by non-high invasive disease potential serotypes.
Collapse
|
29
|
Patent Ductus Arteriosus Banding for Circular Shunting After Pulmonary Valvuloplasty. World J Pediatr Congenit Heart Surg 2016; 8:643-645. [PMID: 27647342 DOI: 10.1177/2150135116655122] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We report two cases of newborns with critical pulmonary stenosis having intact ventricular septum, who underwent pulmonary valve balloon valvuloplasty followed by banding of a patent ductus arteriosus. Transcatheter pulmonary valvuloplasty was performed one week after delivery. Following the procedure, both developed "circular shunting" as a consequence of left-to-right ductal flow and pulmonary regurgitation. This in turn caused increased blood flow into a dysfunctional right ventricle and low systemic cardiac output syndrome. The PDA banding was performed urgently as a rescue measure in order to restore systemic flow while still maintaining some duct-dependent pulmonary blood flow. This approach resolved the circular shunting. Outcome was favorable in both the patients.
Collapse
|