1
|
Marschner CA, Zhang L, Schwarze V, Völckers W, Froelich MF, von Münchhausen N, Schnitzer ML, Geyer T, Fabritius MP, Rübenthaler J, Clevert DA. The diagnostic value of contrast-enhanced ultrasound (CEUS) for assessing hepatocellular carcinoma compared to histopathology; a retrospective single-center analysis of 119 patients1. Clin Hemorheol Microcirc 2021; 76:453-458. [PMID: 33216017 DOI: 10.3233/ch-209221] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND HCC as the 6th most common tumor entity with the fourth highest mortality and an increasing prevalence especially due to today's lifestyle acquires a high attention in the clinical setting. Beside CECT and CEMRI, CEUS depicts a dynamic, low-risk and radiation free imaging method that finds its use mainly in screening and active surveillance programs. PURPOSE The aim of the retrospective study was to evaluate the diagnostic value of CEUS in correlation to pathologic findings. MATERIALS AND METHODS Between 2004 and 2018 a total number of 119 patients were included in this retrospective single-center study. Every patient underwent CEUS in addition to a native B-mode and Color-Doppler scan. After given informed consent SonoVue® (Bracco, Milan, Italy), a second-generation blood-pool agent, was used as contrast medium. Every examination was performed and interpreted by a single experienced radiologist (EFSUMB level 3). A low mechanical index (MI) of <0,2 was chosen to obtain a good imaging quality. RESULTS All 119 included patients received CEUS followed by a liver biopsy for inter-modality comparison. In correlation to the pathology results, CEUS showed a diagnostic sensitivity of 96,6%, a specificity of 63,9%, a PPV of 86,7% and a NPV of 88,5% by detecting liver lesions suspicious for HCC. According to the Cohen's Kappa coefficient (k = 0,659) CEUS shows a strong inter-modality agreement in comparison to the histopathological finding. CONCLUSION With a high sensitivity and a strong cross-modality comparability to histopathology, the CEUS is highly effective in the detection of suspicious HCC lesions.
Collapse
Affiliation(s)
- C A Marschner
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - L Zhang
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - V Schwarze
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - W Völckers
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - M F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany
| | - N von Münchhausen
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany
| | - M L Schnitzer
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - T Geyer
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - M P Fabritius
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - D-A Clevert
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
2
|
Apfelbeck M, Tritschler S, Clevert DA, Buchner A, Chaloupka M, Kretschmer A, Herlemann A, Stief C, Schlenker B. Postoperative change in Gleason score of prostate cancer in fusion targeted biopsy: a matched pair analysis. Scand J Urol 2020; 55:27-32. [PMID: 33380254 DOI: 10.1080/21681805.2020.1849390] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE To evaluate if MRI/ultrasound fusion based targeted biopsy (FBx) leads to a reduced rate of change in Gleason score (GS) compared to prostatectomy specimen. METHODS The histopathological findings of the biopsy of the prostate and the radical prostatectomy (RP) specimen of 210 patients who were referred to our hospital between 2012 and 2017 were compared retrospectively in this study. One hundred and five patients who underwent FBx combined with ultrasound-guided 12-core biopsy of the prostate (SBx) were matched with 105 patients who underwent SBx only. This study evaluated the rate of up- or downgrading in the RP specimen in both groups and compared the results via matched pair analysis. RESULTS Concordance in Gleason grade group (GGG) was found in 52/105 patients (49.5%) in SBx and in 49/105 patients (46.7%) with FBx (p = 0.679). The rate of downgrading was statistically significant (p = 0.014) and was higher in the FBx group (14/105 patients, 13.3%) than in the SBx group (4/105 patients, 3.8%). A higher rate of upgrading was seen in SBx (49/105 patients; 46.7%) compared to FBx (42/105 patients; 40%), with no statistical significance (p = 0.331). The change in GGG from biopsy to final pathology in patients with GGG 1 and 2 at biopsy level was not statistically significant (p = 0.168). CONCLUSION FBx does not decrease the rate of upgrading between biopsy and final pathology in RP specimens. Our results indicate that FBx tends to overestimate the final GGG compared to SBx.
Collapse
Affiliation(s)
- M Apfelbeck
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - S Tritschler
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany.,Department of Urology, Loretto Hospital, Freiburg, Germany
| | - D-A Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound-Center, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - A Buchner
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Chaloupka
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - A Kretschmer
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - A Herlemann
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - C Stief
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| | - B Schlenker
- Department of Urology, LMU Klinikum, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
3
|
Schwarze V, Marschner C, Völckers W, de Figueiredo GN, Rübenthaler J, Clevert DA. The diagnostic performance of contrast-enhanced ultrasound (CEUS) for evaluating hepatocellular carcinoma (HCC) juxtaposed to MRI findings; a retrospective single-center analysis of 292 patients. Clin Hemorheol Microcirc 2020; 76:155-160. [PMID: 32925017 DOI: 10.3233/ch-209213] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND HCC is the most frequent primary liver cancer entity. Major risk factors comprise chronic HBC and HCV infections, ALD or NAFLD. Apart from the anamnesis, the clinical examination and serologic analysis, an essential part of the diagnostic HCC work-up is due to imaging findings from sonography, CT or MRI scans. HCC lesions feature a distinct vascularization pattern: hyperenhancement during early arterial and hypoenhancement/wash-out during portal venous or delayed phases. CEUS facilitates dynamic assessment of microperfusion patterns of suspicious liver lesions. PURPOSE The purpose of the present retrospective single-center study was to determine the diagnostic value of CEUS for assessing HCC by comparison with findings from MRI scans. MATERIALS AND METHODS Between 2004-2018 292 patients with suspicious liver lesions underwent CEUS and MRI. All patients underwent native B-mode, Color Doppler and CEUS after given informed consent. The applied contrast agent was a second-generation blood pool agent (SonoVue®, Bracco, Milan, Italy). Every CEUS examination was performed and interpreted by a single experienced radiologist (EFSUMB Level 3). RESULTS CEUS was performed on all included patients without occurrence of any adverse effects. CEUS showed a sensitivity of 96%, a specificity of 91%, a PPV of 95% and a NPV of 94% for analyzing HCC in comparison with MRI as the diagnostic gold standard. CONCLUSION With a distinguished safety profile CEUS shows a high diagnostic accuracy in assessing HCC compared to corresponding results from MRI scans.
Collapse
Affiliation(s)
- V Schwarze
- Department of Radiology, University Hospital LMU, Munich, Germany
| | - C Marschner
- Department of Radiology, University Hospital LMU, Munich, Germany
| | - W Völckers
- Department of Radiology, University Hospital LMU, Munich, Germany
| | | | - J Rübenthaler
- Department of Radiology, University Hospital LMU, Munich, Germany
| | - D-A Clevert
- Department of Radiology, University Hospital LMU, Munich, Germany
| |
Collapse
|
4
|
Abstract
BACKGROUND Point-of-care ultrasound (POCUS) of the lung in patients with COVID-19 plays a key role in the emergency room and intensive care unit. Lung ultrasound is able to depict typical pulmonary findings of COVID-19 and is therefore suitable for diagnosis and follow-up of these patients. CLINICAL/METHODOLOGICAL ISSUE Lung ultrasound in COVID-19 patients in the emergency room and intensive care unit. STANDARD RADIOLOGICAL METHODS Computed tomography (low-dose CT) and X‑ray of the lung. METHODOLOGICAL INNOVATIONS Lung ultrasound in COVID-19 patients. RECOMMENDATIONS Lung ultrasound in patients with COVID-19 offers similar performance as CT and is superior when compared to X‑ray in evaluating pneumonia and acute respiratory distress syndrome (ARDS). Lung ultrasound plays an important role in the emergency room and intensive care unit. POCUS reduces exposure to radiation, therapy delays, and minimizes transport of high-risk patients. Differential diagnoses can also be clarified.
Collapse
Affiliation(s)
- M Schmid
- Klinik für Gastroenterologie, Pneumologie, Internistische Akut- und Intensivmedizin, München Klinik Harlaching, Sanatoriumsplatz 2, München, 81545, Deutschland
| | - F Escher
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschallzentrum, Klinikum der Ludwig-Maximilians-Universität München, Campus Großhadern, Marchioninistraße 15, 81377, München, Deutschland
| | - D-A Clevert
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschallzentrum, Klinikum der Ludwig-Maximilians-Universität München, Campus Großhadern, Marchioninistraße 15, 81377, München, Deutschland.
| |
Collapse
|
5
|
Schwarze V, Marschner C, de Figueiredo GN, Rübenthaler J, Clevert DA. Contrast-enhanced ultrasound (CEUS) in the diagnostic evaluation of popliteal artery aneurysms, a single-center study. Clin Hemorheol Microcirc 2020; 76:191-197. [PMID: 32925018 DOI: 10.3233/ch-209214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Popliteal artery aneurysms (PAA) are the most common peripheral artery aneurysms. Most common cause is arteriosclerosis. Acute thromboembolic limb ischemia and rupture of the PAA depict severe complications. Diagnostic tools for identifying PAAs are (Doppler) ultrasound, CT/MR angiography and DSA. PURPOSE The aim of the present retrospective single-center study is to assess the application and safety of CEUS for assessing untreated and treated PAAs. MATERIALS AND METHODS 13 patients were included in this study on whom CEUS was performed between 2007-2016. CEUS examinations were performed and interpreted by an experienced single radiologist (EFSUMB Level 3). RESULTS CEUS allowed for the detection of PAAs in all cases. CEUS allowed for detection of partial thrombosis of PAA in 7/8 of untreated patients, proper exclusion of PAA upon femoro-popliteal bypass in 3 patients, incomplete exclusion of PAA upon femoro-popliteal bypass in 1 patient and ruling out of in-stent stenosis in 1 patient. CONCLUSION CEUS is a useful and safe tool for in real-time evaluation of PAAs in the pre-/post-treatment status. In addition to conventional (Doppler) ultrasound and as an alternative tool to more elaborate imaging modalities, CEUS might be integrated in the future diagnostic work-up and follow-up of PAA patients.
Collapse
Affiliation(s)
- V Schwarze
- Department of Radiology, University Hospital LMU, Munich, Germany
| | - C Marschner
- Department of Radiology, University Hospital LMU, Munich, Germany
| | | | - J Rübenthaler
- Department of Radiology, University Hospital LMU, Munich, Germany
| | - D-A Clevert
- Department of Radiology, University Hospital LMU, Munich, Germany
| |
Collapse
|
6
|
Abstract
BACKGROUND Motorsport karting has developed into a professional international competition. Kart racing poses a unique set of physiologic challenges for athletes who compete in this sport. Until today no major study has evaluated the physical and cardiac challenge in professional kart racing. OBJECTIVE The aim for this study was to measure and analyze heart rate and cardiac rhythm by a mobile, smartphone based ECG (s-patch) on professional kart-race-drivers during actual karting races through annual seasons to test the hypotheses that high g-force and stress could trigger cardiac arrhythmia. MATERIAL AND METHODS ECG-data from kart-drivers were acquired during local races, the ADAC Kart-Masters (KZ2), the German Kart Championship (DSKC) and the European Championship Senior CIK-FIA-Serie and analyzed in this observational study. In total, free practice, qualifying practice and 32 races were assessed during the kart season 2019. Data were interpreted by two independent experienced physicians. RESULTS The average heart rate (HR) during a selected German Kart Championship (DSKC) race in Genk (Belgium) was 169 beats min-1. The longest R-R interval was 0.72 sec. The average HR during a selected European Championship CIK-FIA-race in Lonato (Italy) was 160 beats min-1. The longest R-R interval was 0.74 sec. The average HR during a selected ADAC Kart-Masters (KZ2) races in Wackersdorf (Germany) was 147 beats min-1. The longest R-R interval was 0.86 sec. In total 32 races could be recorded successful. No couplets or bigeminy cycles were detected. In one other kart racer a supraventricular extrasystole and a ventricular extrasystole was detected. Interestingly, kart-drivers were found to have sinustachycardia throughout the races most likely triggered by emotional and physiological stress during speeding. CONCLUSION Professional kart racing drivers had sinustachycardia with heart rates up to 193 beats min-1 during races. This is most likely attributed to a considerably high emotional and physiological stress affecting the cardiovascular system. Episodes of tachycardia positively correlated with mean speed. In the warm-up lap the heart rate was significantly lower in comparison to the race, suggesting that faster driving speed would induce greater cardiovascular stress to professional drivers during actual races. The experimental results showed that the proposed S-patch system provided a good ECG signal quality with accurate measurements even during the kart race and could detect the ECG features of the race in real time. The cardiac interpretation software performs well and is a useful tool to assist clinicians.
Collapse
Affiliation(s)
- D Puhr-Westerheide
- Department of Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich, Munich, Germany
| | - T Kostbade
- Kart Racing Team, Kartshop Ampfing, Ampfing, Germany
| | - D-A Clevert
- Department of Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich, Munich, Germany
| |
Collapse
|
7
|
Mittlmeier LM, Unterrainer M, Todica A, Clevert DA, Cyran CC, Schmoeckel E, Rodler S, Bartenstein P, Stief CG, Ilhan H, Staehler M. Advanced Molecular Imaging in Histologically Verified Metanephric Adenoma. Urology 2020; 140:e10-e11. [PMID: 32171695 DOI: 10.1016/j.urology.2020.02.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 02/22/2020] [Accepted: 02/25/2020] [Indexed: 10/24/2022]
Abstract
Metanephric adenoma (MA) describes a rare renal tumor and is generally considered a benign lesion. However, there are cases with regional lymphogenic and distant metastases. Noninvasive diagnosis of MA using conventional imaging remains challenging. Here, we describe a case of histologically verified MA with additional advanced molecular imaging consisting of 18F-PSMA-1007 PET/CT, 99mTc-Sestamibi SPECT and contrast-enhanced ultrasound.
Collapse
Affiliation(s)
- L M Mittlmeier
- Department of Urology, University Hospital, LMU Munich, Munich, Germany; Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
| | - M Unterrainer
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
| | - A Todica
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
| | - D A Clevert
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - C C Cyran
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - E Schmoeckel
- Institute of Pathology, University Hospital, LMU Munich, Munich, Germany
| | - S Rodler
- Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - P Bartenstein
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
| | - C G Stief
- Department of Urology, University Hospital, LMU Munich, Munich, Germany
| | - H Ilhan
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany
| | - M Staehler
- Department of Urology, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
8
|
Negrão de Figueiredo G, Mueller-Peltzer K, Schwarze V, Zhang L, Rübenthaler J, Clevert DA. Performance of contrast-enhanced ultrasound (CEUS) compared to MRI in the diagnostic of gallbladder diseases. Clin Hemorheol Microcirc 2020; 73:85-93. [PMID: 31561332 DOI: 10.3233/ch-199202] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND Conventional ultrasound and MRI are very important techniques for the detection of gallbladder alterations. In the past years, studies showed that the additional use of contrast media to the conventional ultrasound allows the early depiction of pathological microvessels and their flow elucidating suspect findings stipulating the prompt therapy approach. OBJECTIVE The study aims to evaluate the performance of CEUS in gallbladder diseases and compare it to MR imaging using histopathological findings as a gold standard. MATERIAL AND METHODS The retrospective mono-center study analysed 18 patients with gallbladder alterations between 2009 and 2017. All patients underwent CEUS and MRI examinations and all results were confirmed in the pathology. CEUS images were performed and interpreted by a single experienced physician. RESULTS CEUS imaging results compared to MR imaging of the gallbladder demonstrated a sensitivity of 100%, specificity of 93%, a positive predictive value of 67% and a negative predictive value of 100%. CONCLUSION CEUS enables the depiction and characterization of important vascularization's patterns facilitating the early differentiation between malignant and benign findings. In this study, CEUS displayed a better diagnostic accuracy than MRI proving to be a valuable additional tool to the established imaging modalities.
Collapse
Affiliation(s)
- G Negrão de Figueiredo
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - K Mueller-Peltzer
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - V Schwarze
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - L Zhang
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - D A Clevert
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
9
|
Jokisch F, Buchner A, Schulz GB, Grimm T, Weinhold P, Pfitzinger PL, Chaloupka M, Stief CG, Schlenker B, Clevert DA. Prospective evaluation of 4-D contrast-enhanced-ultrasound (CEUS) imaging in bladder tumors. Clin Hemorheol Microcirc 2019; 74:1-12. [PMID: 31743990 DOI: 10.3233/ch-199231] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
PURPOSE The evaluation of the potential clinical benefit of four-dimensional ultrasound (4D-US) in the assessment of bladder cancer (BC). MATERIAL AND METHODS 20 patients with indication for cystoscopy for suspicion of bladder cancer were prospectively included in this study. All patients underwent two-dimensional ultrasound (2D-US), contrast enhanced ultrasound (CEUS) and real-time four-dimensional ultrasound (4D-US). All acquisitions were compared to each other in regard to image quality. This assessment was done using a 6 point scale (1 = best). All patients underwent subsequently cystoscopy with resection of the tumor (TURB), due a histopathological analysis was possible. RESULTS All examinations were performed successfully and no patient had to be excluded from the study. Patients acceptance of 4D-US was consistently good. No adverse events occurred. Image quality of real time 4D-US (score: 1.27±0.46) was significantly superior (p < 0.001) to both, conventional 2D-US (score: 2.33±0.62) and also to 2D-CEUS (score: 2.00±0.53). In terms of tumor detection no superiority was evident for 4D-US compared to 2D-US or in utilization of CEUS (sensitivity = 0.89; specificity = 1.00; positive predictive value = 1.00; negative predictive value = 0.50; AUC = 0.944; (95% CI: 07.43-0.998)). CONCLUSION The assessment of bladder cancer using real time 4D-US is feasible and improves the image quality and therefore also the precise anatomical consistency of intravesical tumor masses.
Collapse
Affiliation(s)
- F Jokisch
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - A Buchner
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - G B Schulz
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - T Grimm
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - P Weinhold
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - P L Pfitzinger
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Chaloupka
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - C G Stief
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - B Schlenker
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - D-A Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound-Center, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
10
|
Abstract
BACKGROUND The incidence of small renal masses has been rising over the last few decades. At the same time, mortality of renal cell carcinoma (RCC) is decreasing. These trends can be explained by the availability of improved therapeutic measures and the good prognosis of small renal masses (SRM) turning out to be histopathologically benign or of low malignancy in many cases. OBJECTIVES The aim of this article is to present epidemiology and diagnostic assessment of SRM. MATERIALS AND METHODS Statistics, basic research, guidelines. RESULTS The incidence of SRM is rising due to the widespread use of imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and contrast-enhanced ultrasound (CEUS). Sensitivity is excellent for CEUS and for CECT in the characterization of SRM, while good specificity values can be reached by MRI. For characterization of complex cystic renal masses, CEUS has good diagnostic accuracy. CONCLUSIONS Due to improved diagnostic possibilities, SRMs can be diagnosed in early asymptomatic stages. As SRM have a good prognosis and often are of low malignancy therapy, options should be carefully considered; especially in older patients, active surveillance should considered.
Collapse
Affiliation(s)
- B K Ziegelmüller
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland.
| | - A Spek
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - B Szabados
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - J Casuscelli
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - D-A Clevert
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - M Staehler
- Urologische Klinik und Poliklinik, Klinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| |
Collapse
|
11
|
Abstract
CLINICAL/METHODICAL ISSUE Focal liver lesions are commonly seen during routine ultrasound examinations. STANDARD RADIOLOGICAL METHODS With native ultrasound there are lesions that cannot be sufficiently characterized. In these cases additional imaging might be necessary. METHODICAL INNOVATIONS With contrast-enhanced ultrasound (CEUS), focal liver lesions can be characterized with high diagnostic accuracy. After the ultrasound contrast agent has been injected into a peripheral vein, the examiner saves video loops of the arterial, portal venous and late contrast phases. Combing the findings of native and contrast-enhanced ultrasound allows not only assessment of the etiology as benign or malignant but also detailed characterization of the focal liver lesion in most cases. PERFORMANCE Using CEUS, focal liver lesions can be characterized with a sensitivity of over 95% and a specificity of about 83%. ACHIEVEMENTS The advantages of CEUS include that there is no radiation exposure and that the ultrasound contrast agent has no effects on the function of the liver, kidneys or the thyroid gland. The main limiting factors for CEUS are bowel gas and obesity of the patient. PRACTICAL RECOMMENDATIONS CEUS can visualize micro- and macrovascularization of benign focal liver lesions in real time. It is a useful imaging modality in unclear cases.
Collapse
Affiliation(s)
- K Müller-Peltzer
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland.
| | - J Rübenthaler
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - G Negrao de Figueiredo
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - D A Clevert
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum der Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| |
Collapse
|
12
|
Abstract
CLINICAL/METHODICAL ISSUE Cystic renal lesions are common incidental findings in radiological imaging and they should be adequately examined to be able to characterize them as benign or malignant. STANDARD RADIOLOGICAL METHODS It is not always possible to sufficiently characterize cystic renal lesion solely using native B‑mode sonography and color-Doppler sonography. METHODICAL INNOVATIONS Using contrast-enhanced ultrasound (CEUS), it is possible to dynamically evaluate the perfusion of cystic renal lesions and to characterize the potential malignancy of these lesions using the Bosniak classification in order to give recommendations regarding further work-up. CEUS can also be used in patients with contraindications for other radiological imaging modalities as it uses a contrast agent with almost no side effects. PERFORMANCE Using CEUS, cystic renal lesions can be reliably characterized with a diagnostic accuracy greater than 90%. ACHIEVEMENTS CEUS is a useful method in diagnosing and characterizing unclear cystic renal lesions and should always be considered as a viable diagnostic tool. PRACTICAL RECOMMENDATIONS CEUS should always be performed in initially unclear cases and is a useful additional tool for the diagnosis and characterization of unclear cystic renal lesions.
Collapse
Affiliation(s)
- J Rübenthaler
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland.
| | - K Mueller-Peltzer
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - G Negrão de Figueiredo
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - E Gresser
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| | - D A Clevert
- Klinik und Poliklinik für Radiologie, Interdisziplinäres Ultraschall-Zentrum, Universitätsklinikum, Ludwig-Maximilians-Universität München, Marchioninistr. 15, 81377, München, Deutschland
| |
Collapse
|
13
|
Negrão de Figueiredo G, Mueller-Peltzer K, Zengel P, Armbruster M, Rübenthaler J, Clevert DA. Contrast-enhanced ultrasound (CEUS) and gallbladder diseases - A retrospective mono-center analysis of imaging findings with histopathological correlation. Clin Hemorheol Microcirc 2019; 71:151-158. [PMID: 30584127 DOI: 10.3233/ch-189405] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND Radiologic imaging, especially ultrasound has an important role in the assessment of gallbladder alteration. Contrast-enhanced ultrasound (CEUS) is an easy and fast imaging technique that overcomes the limitations of greyscale ultrasonography. It is a safe tool that can be used as an additional imaging modality in order to elucidate and differentiate gallbladder pathological findings. OBJECTIVE The aim of this retrospective study analysis is to assess the diagnostic performance of CEUS in gallbladder alterations and compare the results to the histopathological findings. METHODS A total of 17 patients between 2009 and 2017 with uncertain gallbladder appearance were retrospectively analysed. A single experienced physician with more than fifteen years' experience performed CEUS examinations by applying a second-generation blood pool agent (SonoVue®, Bracco, Milan, Italy). Archived images were interpreted by the same physician and compared to the histopathological findings. RESULTS CEUS results, when correlated to the respectively pathologic findings, presented a sensitivity of 100%, a specificity of 100%, a positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 100%. All patients were successfully examined without any adverse reaction. CONCLUSION In conclusion, the excellent results in this study acknowledged that CEUS is a feasible alternative tool to differentiate gallbladder pathologic alterations.
Collapse
Affiliation(s)
- G Negrão de Figueiredo
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - K Mueller-Peltzer
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - P Zengel
- Department of Otorhinolaryngology, Head and Neck Surgery, Ludwig-Maximilians-Universität München, Munich, Germany
| | - M Armbruster
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| | - D A Clevert
- Department of Radiology, Interdisciplinary Ultrasound-Center Ludwig-Maximilians-University of Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
14
|
Schlenker B, Apfelbeck M, Armbruster M, Chaloupka M, Stief CG, Clevert DA. Comparison of PIRADS 3 lesions with histopathological findings after MRI-fusion targeted biopsy of the prostate in a real world-setting. Clin Hemorheol Microcirc 2019; 71:165-170. [PMID: 30562897 DOI: 10.3233/ch-189407] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
INTRODUCTION We aimed to evaluate whether PIRADS 3 lesions in multiparametric MRI (mpMRI) represent a significant risk of prostate cancer (PCa) in a real-world setting of different referring radiologic institutes. MATERIALS AND METHODS Between May 2015 and October 2017, a total of 408 patients were referred to our clinic for MRI-ultrasound fusion targeted biopsy of the prostate (FusPbx) due to suspected prostate cancer. In all patients, preoperatively an mpMRI of the prostate was performed by altogether 62 different radiologic institutes. Prostate lesions were classified according to the PIRADS system. A PIRADS 3 lesion was diagnosed in 41 patients. FusPbx was performed transrectally using a Philips EPIQ 7 (Philips Medical Systems, Bothell, WA) scanner with plane wise fusion of ultrasound and MRI image data. In addition to FusPbx in each patient a randomized 12-core transrectal ultrasound guided biopsy (USPbx) was performed. RESULTS Mean PSA Level was 9.5 ng/ml (range: 1- 26 ng/ml), mean patients age was 66.1 years (48.6- 80.4). In 11/41 patients (26.8%) prostate cancer was diagnosed by FusPbx of the PIRADS 3 lesion. In the target lesion PCa was classified as Gleason Score 3+3 in 5 patients, as 3+4 in 3, 4+3 in 1, 4+4 in 1 and 4+5 in 1 patient. In patients with negative FusPbx USPbx revealed PCa in another 7 patients (17.1%). In 5 of these GS 3+3 PCa was found, in another 2 patients GS 3+4 PCa. CONCLUSIONS PIRADS 3 lesion indicates an equivocal likelihood of significant prostate cancer. In our series the overall PCa detection rate was 26.8% and 14.6% for clinically significant cancer in PIRADS 3 lesions. This evokes the question, if PIRADS 3 lesions could be surveilled only. The findings should be confirmed in a larger series.
Collapse
Affiliation(s)
- B Schlenker
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Apfelbeck
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Armbruster
- Department of Clinical Radiology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Chaloupka
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - C G Stief
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - D-A Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound-Center, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
15
|
Schlenker B, Apfelbeck M, Buchner A, Stief C, Clevert DA. MRI-TRUS fusion biopsy of the prostate: Quality of image fusion in a clinical setting. Clin Hemorheol Microcirc 2019; 70:433-440. [PMID: 30347605 DOI: 10.3233/ch-189308] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Prostate cancer (PCa) is one of the most common malignancies in men. The diagnostic standard to confirm prostate cancer is the transrectal ultrasound-guided biopsy. However, this procedure is associated with the underdetection of clinically significant prostate cancer and therefore needs to be improved. In the last years MRI fusion based targeted biopsy gained importance as consequence. In this study, we evaluated the quality of MRI ultrasound image fusion and evaluated factors influencing the image fusion quality. This was done by comparing fusion quality with the histopathological findings in the defined MRI target on the one hand and the PIRADS score on the other hand. MATERIALS AND METHODS Single arm study including patients with elevated prostate specific antigen (PSA) and a multiparametric MRI showing a suspicious lesion underwent a MRI fusion targeted biopsy at our institution. MRI fusion targeted biopsy and an additional 12-core transrectal ultrasound (TRUS) guided biopsy was performed using the Philips Percunav device (Philips Medical Systems, Bothell, WA). The fusion accuracy was rated by two experienced clinicians (1 radiologist, 18 years of experience, 1 urologist, 5 years of experience) using a five-point rank scale (1 = best) and comparing the result with the histological findings in the target and the PIRADS score. RESULTS The detection rate of clinically significant cancer (Gleason 7a or greater) by MRI-ultrasound fusion targeted biopsy was 58.6% (17/29) compared to 50% (19/38) in the standard transrectal ultrasound-guided approach. PCa was found in 36.4% (4/11 patients) of patients with a PIRADS 3 lesion, in 57.7% (15/26 patients) of patients with a PIRADS 4 lesion. In 76.9% (10/13 patients) of patients with a PIRADS 5 lesion PCa was diagnosed. No statistical significance was found comparing the quality of registration either with the PIRADS (p = 0.7873) nor with the Gleason score (p = 0.4376). The study is limited by the small number of patients. CONCLUSIONS MRI fusion based targeted biopsy improves the identification of clinical significant cancer. The Gleason score of detected PCa is not influenced by the quality of fusion.
Collapse
Affiliation(s)
- B Schlenker
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - M Apfelbeck
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - A Buchner
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - C Stief
- Department of Urology, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| | - D-A Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound-Center, University Hospital Grosshadern, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
16
|
Mueller-Peltzer K, Negrão de Figueiredo G, Fischereder M, Habicht A, Rübenthaler J, Clevert DA. Vascular rejection in renal transplant: Diagnostic value of contrast-enhanced ultrasound (CEUS) compared to biopsy. Clin Hemorheol Microcirc 2018; 69:77-82. [PMID: 29630540 DOI: 10.3233/ch-189115] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND Despite of the more potent immunosuppressive medication, vascular rejection is still a major issue after renal transplantation. Renal biopsy is the gold standard diagnostic to evaluate acute and chronic allograft rejection. As it is an invasive diagnostic there is the risk of complications like haematoma, arteriovenous fistulas, active bleeding or infection. Contrast-enhanced ultrasound is a non-invasive imaging modality that allows visualising renal transplant perfusion. OBJECTIVE To analyse the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) compared to biopsy as gold standard in diagnosing vascular rejection in renal transplant patients. METHODS A total of 57 renal transplant recipients with poor renal allograft function with initial diagnostic imaging between 2006 and 2017 were included in the study. Clinical data and imaging studies were analysed retrospectively. The diagnostic accuracy of CEUS in diagnosing vascular rejection of the renal transplant was compared to renal biopsy as gold standard. Out of 57 patients 7 patients showed signs of vascular rejection in biopsy. In 6 out of these 7 patients CEUS described irregularities in renal perfusion suspicious of vascular rejection. RESULTS CEUS showed a sensitivity of 85.7%, a specificity of 100%, a positive predictive value (PPV) of 100%, and a negative predictive value (NPV) of 98.0%. CONCLUSIONS CEUS is a safe, non-nephrotoxic imaging modality for the initial imaging of renal transplant recipients with elevated kidney function parameters suspicious of vascular rejection. Compared to renal biopsy as gold standard CEUS shows a high specificity and PPV in detecting signs of vascular rejection. Since sub-types of vascular rejection with cellular and humoral components with greater risk for allograft loss have been described renal biopsy is inevitable in these cases.
Collapse
Affiliation(s)
- K Mueller-Peltzer
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - G Negrão de Figueiredo
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - M Fischereder
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - A Habicht
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - D-A Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
17
|
Mueller-Peltzer K, Negrão de Figueiredo G, Fischereder M, Habicht A, Rübenthaler J, Clevert DA. Contrast-enhanced ultrasound (CEUS) as a new technique to characterize suspected renal transplant malignancies in renal transplant patients in comparison to standard imaging modalities. Clin Hemorheol Microcirc 2018; 69:69-75. [PMID: 29630539 DOI: 10.3233/ch-189114] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Renal transplant patients have a higher risk for malignancies of the renal transplant. In most cases suspected renal malignancies will be detected during the regular ultrasound follow-up and will require cross-sectional imaging to rule out a malignant aetiology. But it is well known that contrast agents for computed tomography or magnetic resonance imaging are critical in patients with limited renal function. OBJECTIVE This study aims to compare the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and gold standard imaging modalities in characterizing suspected renal transplant malignancies in renal transplant patients. METHODS A total of 22 renal transplant patients who underwent one or more CEUS examinations and at least one standard imaging modality (CT or MRI) between 2005 and 2017 were included. Patient ages ranged from 28.2 years to 74.6 (mean age 55.7 years; SD±13.0 years). CEUS of 22 patients was correlated with a standard imaging modality, CT (15 out of 22) or MRI (7 out of 22), serving as gold standard. RESULTS CEUS showed a sensitivity of 100%, a specificity of 94.4%, a positive predictive value (PPV) of 80%, and a negative predictive value (NPV) of 100%. CONCLUSIONS CEUS is an eligible method to help characterizing suspected renal malignancies in renal transplant patients compared to the well-established imaging modalities CT and MRI. As an imaging modality with no nephrotoxic effects CEUS can be used repeatedly even in patients with limited renal function.
Collapse
Affiliation(s)
- K Mueller-Peltzer
- Department of Radiology, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| | - G Negrão de Figueiredo
- Department of Radiology, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| | - M Fischereder
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| | - A Habicht
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| | - D-A Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich-Grosshadern Campus, Munich, Germany
| |
Collapse
|
18
|
Mueller-Peltzer K, Rübenthaler J, Fischereder M, Habicht A, Reiser M, Clevert DA. The diagnostic value of contrast-enhanced ultrasound (CEUS) as a new technique for imaging of vascular complications in renal transplants compared to standard imaging modalities. Clin Hemorheol Microcirc 2018; 67:407-413. [PMID: 28885208 DOI: 10.3233/ch-179221] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND Vascular complications in renal transplant patients are a well-known issue in post transplant patient care. If malfunctioning of the renal transplant is suspected to be caused by vascular complications an early diagnosis and therapy is required to maintain the renal transplant. Computed tomography (CT), digital substraction angiography (DSA) and radioisotope renography are the gold standard imaging modalities to diagnose vascular complications. OBJECTIVE To analyse the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) in comparison to the standard imaging modalities CT, DSA and radioisotope renography in the diagnosis of vascular complications in renal transplant patients. METHODS A total of 33 renal transplant recipients with elevated kidney function parameters with initial diagnostic imaging between 2006 and 2017 were included in the study. The imaging studies and clinical data were analysed retrospectively. The diagnostic accuracy of CEUS was compared to CT, DSA and renal scintigraphy respectively which are classified as gold standard for diagnosis of vascular complications in renal transplant patients. Out of 23 patients 15 patients showed vascular complications in CT, DSA or radioisotope renography and in 15 out of 15 patients CEUS detected the vascular complication. RESULTS CEUS showed a sensitivity of 100%, a specificity of 66.7%, a positive predictive value (PPV) of 71.4%, and a negative predictive value (NPV) of 100%. CONCLUSIONS CEUS is a non-nephrotoxic and safe method for the initial imaging of vascular complications in renal transplant recipients. Compared to the gold standard imaging modalities CT, DSA and radioisotope renography CEUS shows a high sensitivity and NPV in detecting vascular complications. In cases with suspected stenosis of the transplant renal artery additional DSA might be needed.
Collapse
Affiliation(s)
- K Mueller-Peltzer
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - J Rübenthaler
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - M Fischereder
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - A Habicht
- Department of Internal Medicine IV, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - M Reiser
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| | - D-A Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich - Grosshadern Campus, Munich, Germany
| |
Collapse
|
19
|
Mumm JN, Clevert DA, Ziegelmüller B. [Unclear renal masses in ultrasound]. MMW Fortschr Med 2018; 160:48-50. [PMID: 29556996 DOI: 10.1007/s15006-018-0291-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Affiliation(s)
- Jan-Niclas Mumm
- Urologische Klinik und Poliklinik, LMU München, Campus Großhadern, Marchioninistr. 15, D-81377, München, Deutschland.
| | - D A Clevert
- Klinik für Radiologie, LMU München, München, Deutschland
| | | |
Collapse
|
20
|
Rübenthaler J, Paprottka KJ, Hameister E, Hoffmann K, Joiko N, Reiser M, Rjosk-Dendorfer R, Clevert DA. Contrast-enhanced ultrasound (CEUS) prediction of focal liver lesions in patients after liver transplantation in comparison to histopathology results. Clin Hemorheol Microcirc 2018; 66:303-310. [PMID: 28527201 DOI: 10.3233/ch-179104] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE To investigate the value of contrast-enhanced ultrasound (CEUS) in histologic prediction of focal liver lesions after liver transplantation. MATERIALS AND METHODS 10 focal liver lesions in 10 patients after liver transplantation were scanned using CEUS and the CEUS results were compared with the histopathological results. RESULTS Among 10 focal liver lesions, 7 proofed to be histopathological benign and 3 lesions proofed to be histopathological malignant. All lesions (100%) were correctly report as benign or malignant in the report of the CEUS examination. CONCLUSION CEUS can be helpful in the differentiation of benign and malignant focal liver lesions in patients after liver transplantation and can be used in clinical management of focal liver lesions.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K J Paprottka
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - E Hameister
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K Hoffmann
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - N Joiko
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - R Rjosk-Dendorfer
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| |
Collapse
|
21
|
Rübenthaler J, Paprottka KJ, Hameister E, Hoffmann K, Joiko N, Reiser M, Rjosk-Dendorfer D, Clevert DA. Diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in monitoring vascular complications in patients after liver transplantation - diagnostic performance compared with histopathological results. Clin Hemorheol Microcirc 2018; 66:311-316. [PMID: 28527202 DOI: 10.3233/ch-179105] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
PURPOSE To analyse the diagnostic performance of contrast-enhanced ultrasound (CEUS) in patients with vascular complications and transplant rejection compared to histopathological results. MATERIALS AND METHODS Our study consisted of 45 retrospectively analysed patients that underwent liver transplantations between January 1993 and December 2015 and developed post-transplant vascular complications with transplant rejection. CEUS examinations took place between September 2006 and December 2015. CEUS findings were correlated with histopathological results. RESULTS CEUS showed a sensitivity of 61.5%, a specificity of 100.0%, a positive predictive value (PPV) of 100.0% and a negative predictive value (NPV) of 86,5% in the detection of vascular complications with post-transplant rejection. 5 examinations were reported as normal whereas the histopathological result showed a transplant rejection (false-negative). CONCLUSION CEUS might be a useful additional non-invasive technique for the assessment of vascular complications with post-transplant rejection in patients after liver transplantation.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K J Paprottka
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - E Hameister
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K Hoffmann
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - N Joiko
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - D Rjosk-Dendorfer
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| |
Collapse
|
22
|
Rübenthaler J, Paprottka K, D'Anastasi M, Reiser M, Clevert DA. Diagnosis of perinephric retroperitoneal lymphangioma supported by contrast-enhanced ultrasound (CEUS). Clin Hemorheol Microcirc 2017; 65:43-47. [PMID: 27716656 DOI: 10.3233/ch-169000] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Lymphangiomas are a rare condition, which are characterized by multiple cystic lesions of a single or multiple organs that are thought to originate from intrauterine atypically distended and connected lymphatic tissue. We describe a case of a 56 years old woman with the final diagnosis of a perinephric lymphangioma. With the use of contrast-enhanced ultrasound (CEUS) it was possible to add valuable diagnostic information regarding the extent of the lymphangioma to surrounding tissue without the necessity to use additional ionizing radiation or nephrotoxic contrast agents.
Collapse
|
23
|
Abstract
New clinical and technological advances in the field of magnetic resonance imaging (MRI) and targeted image-guided biopsy techniques have significantly improved the detection, localization and staging as well as active surveillance of prostate cancer in recent years. Multiparametric MRI (mpMRI) is currently the main imaging technique for the detection, characterization and diagnostics of metastasizing prostate cancer and is of high diagnostic importance for local staging within the framework of the detection of prostate cancer.
Collapse
Affiliation(s)
- D Nörenberg
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland.
| | - O Solyanik
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland
| | - B Schlenker
- Urologische Klinik und Poliklinik, Klinikum der Universität München, Campus Großhadern, München, Deutschland
| | - G Magistro
- Urologische Klinik und Poliklinik, Klinikum der Universität München, Campus Großhadern, München, Deutschland
| | - B Ertl-Wagner
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland
| | - D A Clevert
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland
| | - C Stief
- Urologische Klinik und Poliklinik, Klinikum der Universität München, Campus Großhadern, München, Deutschland
| | - M F Reiser
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland
| | - M D'Anastasi
- Institut für Klinische Radiologie, Klinikum der Universität München, Campus Großhadern, Marchioninistrasse 15, 81377, München, Deutschland
| |
Collapse
|
24
|
Rübenthaler J, Paprottka KJ, Marcon J, Reiser M, Clevert DA. MRI and contrast enhanced ultrasound (CEUS) image fusion of renal lesions. Clin Hemorheol Microcirc 2017; 64:457-466. [PMID: 27886003 DOI: 10.3233/ch-168116] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Ultrasound is a common and established imaging method for the initial characterization of renal lesions. The widespread used Bosniak classification (I-IV) classifies renal lesions in five individual groups using contrast-enhanced computer tomography (CE-CT), magnetic resonance imaging (MRI) and/or contrast-enhanced ultrasound (CEUS) imaging criteria. For complex pathologies, CEUS/MRI image fusion is a novel imaging technique for the differentiation of benign and malignant renal lesions. Compared to CE-CT and MRI alone, ultrasound image fusion offers the additional possibility of being a real-time imaging technique that can be used together with other cross-sectional imaging techniques.This article describes the newest possibilities of image fusion with CEUS and MRI in detection and characterization of unclear renal lesions.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - K J Paprottka
- Department of Clinical Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - J Marcon
- Department of Urology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Interdisciplinary Ultrasound Center, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| |
Collapse
|
25
|
Rübenthaler J, Paprottka KJ, Hameister E, Hoffmann K, Joiko N, Reiser M, Clevert DA. Malignancies after liver transplantation: Value of contrast-enhanced ultrasound (CEUS). Clin Hemorheol Microcirc 2017; 64:467-473. [PMID: 27935549 DOI: 10.3233/ch-168117] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PURPOSE To evaluate the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and computed tomography (CT) in the diagnosis of malignancies after liver transplantation. MATERIALS AND METHODS A total of 23 patients with suspicious liver masses after liver transplantation with initial imaging series between September 2006 and September 2015 were statistically analysed. CEUS and CT were compared in their diagnosis of malignancy with CT being the gold standard. Out of 23 patients 9 patients showed malignant masses in CT, which could also be detected in 7 out 9 of cases using CEUS. RESULTS CEUS showed a sensitivity of 77.8%, a specificity of 100.0%, a positive predictive value (PPV) of 100.0% and a negative predictive value (NPV) of 87,5% in comparison with CT being the gold standard. In 2 cases CT showed a malignancy, contrary to the CEUS examination that was reported as normal. CONCLUSION CEUS seems to be an alternative option for the evaluation of malignant masses in liver transplant patients. CEUS shows a high specificity and PPV in the detection of malignant liver masses.
Collapse
|
26
|
Rübenthaler J, Paprottka K, Marcon J, Hameister E, Hoffmann K, Joiko N, Reiser M, Clevert DA. Comparison of magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS) in the evaluation of unclear solid renal lesions. Clin Hemorheol Microcirc 2017; 64:757-763. [PMID: 27767985 DOI: 10.3233/ch-168034] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
PURPOSE To compare the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) in the evaluation of unclear renal lesions to the histopathological outcome. MATERIALS AND METHODS A total of 36 patients with a single unclear solid renal lesion with initial imaging studies between 2005 and 2015 were included. CEUS and MRI were used for determining malignancy or benignancy and initial findings were correlated with the histopathological outcome. Out of the 36 renal masses a total of 28 lesions were malignant (77.8%) and 8 were found to be benign (22.2%). Diagnostic accuracy was testes by using the histopathological diagnosis as the gold standard. RESULTS CEUS showed a sensitivity of 96.4%, a specificity of 100.0%, a positive predictive value (PPV) of 100.0% and a negative predictive value (NPV) of 88,9%. MRI showed a sensitivity of 96.4%, a specificity of 75.0%, a PPV of 93.1% and a NPV of 85.7%. Out of the 28 malignant lesions a total of 18 clear cell renal carcinomas, 6 papillary renal cell carcinomas and 4 other malignant lesions, e.g. metastases, were diagnosed. Out of the 8 benign lesions a total 3 angiomyolipomas, 2 oncocytomas, 1 benign renal cyst and 2 other benign lesions, e.g. renal adenomas were diagnosed. Using CEUS, 1 lesion was falsely identified as benign. Using MRI, 2 lesions were falsely identified as benign and 1 lesion was falsely identified as malignant. CONCLUSION CEUS is an useful method which can be additionally used to clinically differentiate between malignant and benign renal lesions. CEUS shows a comparable sensitivity, specificity, PPV and NPV to MRI. In daily clinical routine, patients with contraindications for other imaging modalities can particularly benefit using this method.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K Paprottka
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - J Marcon
- Department of Urology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - E Hameister
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - K Hoffmann
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - N Joiko
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Munich, Germany
| |
Collapse
|
27
|
Reimann R, Rübenthaler J, Hristova P, Staehler M, Reiser M, Clevert DA. Characterization of histological subtypes of clear cell renal cell carcinoma using contrast-enhanced ultrasound (CEUS). Clin Hemorheol Microcirc 2017; 63:77-87. [PMID: 26484711 DOI: 10.3233/ch-152009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
INTRODUCTION The aim of this study was to analyze the histological subtypes of clear cell renal cell carcinoma (RCC) examined by means of contrast-enhanced ultrasound (CEUS) and a second generation blood pool agent (SonoVue®, Bracco, Milan, Italy) during the pre-operative phase. MATERIALS AND METHODS 29 patients with histologically proven subtypes of clear cell RCC were examined. A total of three patients were diagnosed with highly differentiated clear cell RCC, 21 out of 29 cases with moderately differentiated clear cell RCC and five out of 29 patients had insufficiently differentiated clear cell RCC. An experienced radiologist examined the patients with CEUS. The following parameters were analyzed: maximum signal intensity (PEAK), time elapsed until PEAK is reached (MTT), local blood flow (RBF), area under the time intensity curve (AUC) and the signal intensity (SI) during the course of time. For the groups all comparisons are made based on healthy renal parenchyma. RESULTS In the clear cell RCC significant differences (significance level p < 0.05) between cancerous tissue and the healthy renal parenchyma were noticed in all four parameters. Therefore, the clear cell RCC stands out due to its reduced blood volume. However, it reached the PEAK reading relatively rapidly and its signal intensity was always lower than that of the healthy renal parenchyma. In the arterial phase retarded absorption of the contrast agent was observed, followed by fast washing out of the contrast agent bubbles.In all three histological subgroups no significant differences were noticed in PEAK and SI. However, the diagrams showed the possible bias, that the group of the insufficiently differentiated clear cell RCC had the highest PEAK-value and the highest signal intensity when compared with highly and moderately differentiated clear cell RCC. CONCLUSION Our study suggests that CEUS may be an additional tool for non-invasive characterisation and differentiation of the three histological subtypes of clear cell RCC. Furthermore, it seems to have an additional diagnostic value in daily clinical.
Collapse
Affiliation(s)
- R Reimann
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - P Hristova
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - M Staehler
- Department of Urology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| |
Collapse
|
28
|
Zimmermann H, Rübenthaler J, Rjosk-Dendorfer D, Helck A, Reimann R, Reiser M, Clevert DA. Comparison of portable ultrasound system and high end ultrasound system in detection of endoleaks. Clin Hemorheol Microcirc 2017; 63:99-111. [PMID: 26484713 DOI: 10.3233/ch-152011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE To compare the value of a portable ultrasound system and a high end ultrasound system in detection of endoleaks after EVAR. MATERIAL AND METHODS In this retrospective study, a cohort of 25 patients underwent both standard examination using a portable ultrasound system (Philips VISIQ) and a second examination using a high end ultrasound system (Philips EPIQ 7). The examination included B-mode and color Doppler in detection of endoleaks. Additional the maximum diameter of the aneurysm was measured in two planes (right-left and ventral-dorsal). The gold standard was contrast-enhanced ultrasound (CEUS) in detection of endoleaks. RESULTS 25 patients were included in the study. Patients were predominantly male (n = 23) with an average age of 73,30±7.82 years (range 54-85). Diameters of the treated aneurysms were in the right-left plane 5,32±1.88 cm and ventral-dorsal 4,99±1.78 cm using the high end system. Diameters of the treated aneurysms were in the right-left plane 5,30±1.82 cm and ventral-dorsal 4,87±1.74 cm using portable ultrasound system. In 80% of the cases CEUS could detect an endoleak. Whereas the high end system could detect in B-mode 40% and color Doppler 45% of the cases an endoleak. The portable system could detect in B-mode 30% and in color Doppler 35% of the cases an endoleak. On both systems in B-mode a false positive endoleak was found on the same patient. All high flow endoleaks, which needed intervention, could be detected on all systems. CONCLUSION The high end ultrasound system does not seem to have an additional advantage in the measurement of the aneurysm diameter. Due to a higher resolution, more endoleaks could be detected in B-mode and color Doppler by using the high end system. The presence of small endoleaks could only be detected by using contrast enhanced ultrasound on an high end ultrasound system. High flow endoleaks could be reliable seen on both systems.
Collapse
|
29
|
Rübenthaler J, Reimann R, Hristova P, Staehler M, Reiser M, Clevert DA. Parametric imaging of clear cell and papillary renal cell carcinoma using contrast-enhanced ultrasound (CEUS). Clin Hemorheol Microcirc 2017; 63:89-97. [PMID: 26484712 DOI: 10.3233/ch-152010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
PURPOSE The aim of this study was to analyse clear cell and papillary renal cell carcinoma (RCC) examined with contrast-enhanced ultrasound (CEUS) and a second generation blood pool agent (SonoVue®, Bracco, Milan, Italy) before clinical intervention. MATERIALS AND METHODS A total of 41 patients with histologically proven subtypes of RCC were examined. 29 patients had a clear cell RCC and 12 patients showed a papillary RCC. Average size in the clear cell RCC group was 6.07 cm and 1.88 cm in the papillary RCC group. An experienced radiologist examined all patients with CEUS. The following parameters were analysed: maximum signal intensity (PEAK), time elapsed until PEAK is reached (MTT), local blood flow (RBF), area under the time intensity curve (AUC) and the signal intensity (SI) during the course of time. For both groups all comparisons were made based on healthy renal parenchyma. RESULTS In the clear cell RCC significant differences (significance level p < 0.05) between cancerous tissue and the healthy renal parenchyma were noticed in all four parameters. The clear cell RCC showed a significant reduced blood volume. It reached the PEAK reading relatively rapidly and its signal intensity was always lower than that of the healthy renal parenchyma. In the arterial phase retarded absorption of the contrast agent was observed, followed by fast washing out of the contrast agent bubbles.In the papillary RCC group, significant findings as to PEAK and RBF as well as a slightly significant difference as to AUC were recorded. The papillary RCC had a lower blood supply and reached its PEAK reading later. Its signal intensity was also reduced. The signal intensity of papillary NCC was significantly lower compared with clear cell RCC; absorption and washing out of the contrast agent was delayed. CONCLUSION CEUS seems to be an useful additional method to clinically differentiate between clear cell and papillary RCC. In daily clinical use, patients with contraindication for other imaging methods, especially the magnetic resonance imaging, might particularly benefit from this method.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - R Reimann
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - P Hristova
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - M Staehler
- Department of Urology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Grosshadern Campus, Marchioninistr., Munich, Germany
| |
Collapse
|
30
|
Witt M, Frielinghausen J, Mueller R, Mueller F, Proft F, Schulze-Koops H, Grunke M, Clevert DA. Evaluation of a Novel Semi-Automated Ultrasound System for the Detection of Synovitis: A Prospective Study involving 45 Patients with Rheumatoid Arthritis. Ultrasound Int Open 2016; 2:E117-E123. [PMID: 27921093 DOI: 10.1055/s-0042-115774] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2016] [Accepted: 08/04/2016] [Indexed: 10/21/2022] Open
Abstract
Background: Arthrosonography has proven to be more sensitive and reliable for the detection of synovitis than clinical examination, but a comprehensive examination of small joints is time-consuming. The automated breast volume scanner (ABVS) has been developed to allow automatic and reproducible series of consecutive B-mode pictures of the female breast. Objectives: To analyze the comparability of ABVS and conventional manual ultrasonography (mUS) for the detection of synovitis in hands and feet of patients with rheumatoid arthritis (RA). Methods: 45 patients with early and established active rheumatoid arthritis were recruited for this trial. All subjects were assessed clinically and by manual (Esaote MyLab70) and automated ultrasound (ACUSON S2000™ ABVS). The wrists, the metacarpophalangeal and proximal interphalangeal joints of the hands and the metatarsophalangeal joints of the feet were examined. Results: A total of 2 340 joint aspects were examined with both methods. ABVS detected 291 grade 1, 124 grade 2, 100 grade 3 cases of synovitis (515 in total) compared to 267, 180 and 145 cases of synovitis (592 in total) with mUS. 242 erosions and 52 cases of tenosynovitis were found by ABVS compared to 244 erosions and 99 cases of tenosynovitis found by mUS. Kappa coefficients for the agreement between both methods ranged from 0.51 in PIP joints to 0.71 in MCP joints. The correlations with clinical parameters as well as interrater agreements were comparable for both ultrasound methods. Conclusion: Based on the results, ABVS seems to be a promising technology for the comprehensive and time-saving assessment of synovitis in RA.
Collapse
Affiliation(s)
- M Witt
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - J Frielinghausen
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - R Mueller
- Division of Rheumatology, Kantonsspital St. Gallen, St. Gallen, Switzerland
| | - F Mueller
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - F Proft
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - H Schulze-Koops
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - M Grunke
- Division of Rheumatology, Med. Klinik und Poliklinik IV, University of Munich, Munich, Germany
| | - D-A Clevert
- Department of Clinical Radiology, University of Munich, Munich, Germany
| |
Collapse
|
31
|
Abstract
CLINICAL/METHODICAL ISSUE For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. METHODICAL INNOVATIONS Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. PERFORMANCE With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. ACHIEVEMENTS Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. PRACTICAL RECOMMENDATIONS In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.
Collapse
Affiliation(s)
- E M Jung
- Institut für Röntgendiagnostik, Universitätsklinikum Regensburg (UKR), Regensburg, Deutschland
| | - D-A Clevert
- Institut für Klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Campus Großhadern, Marchioninistr. 15, 81377, München, Deutschland.
| |
Collapse
|
32
|
Paprottka PM, Zengel P, Cyran CC, Paprottka KJ, Ingrisch M, Nikolaou K, Reiser MF, Clevert DA. Evaluation of multimodality imaging using image fusion with MRI and CEUS in an experimental animal model. Clin Hemorheol Microcirc 2016; 61:143-50. [PMID: 26519228 DOI: 10.3233/ch-151986] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
PURPOSE To evaluate the diagnostic benefits of multimodality imaging using image fusion with magnetic-resonance-imaging (MRI) and contrast-enhanced-ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model for the assessment of tissue hemodynamics and morphology. MATERIAL AND METHODS Human hypopharynx-carcinoma-cells were injected subcutaneously into the left flank of 15 female athymic nude rats. After 10 daysof subcutaneous tumor growth, CEUS and MRI measurements were performed using a high-end-ultrasound-system and 3-T-MRI. After successful point-to-point or plan registration, the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologists using a subjective 5-point scale. RESULTS CEUS and MRI are well-known techniques for the assessment of tissue hemodynamics (score: mean 3.8 ± 0.4 SD and score 3.8 ± 0.4 SD). Real-time image fusion of MRI and CEUS yielded a significant (p < 0.001) improvement in score (score 4.8 ± 0.4 SD). Reliable detection of small necrotic areas was possible in all animals with necrotic tumors. No significant intraobserver and interobserver variability was detected (kappa coefficient = +1). CONCLUSION Image fusion of MRI and CEUS gives a significant improvement for reliable differentiation between different tumor tissue areas and simplifies investigations by showing the morphology as well as surrounding macro-/microvascularization.
Collapse
Affiliation(s)
- P M Paprottka
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - P Zengel
- Institute for Ear, Nose and Throat Medicine, Munich, Germany
| | - C C Cyran
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - K J Paprottka
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - M Ingrisch
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - K Nikolaou
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - M F Reiser
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| | - D A Clevert
- Institute for Clinical Radiology, Ludwig Maximilian University Hospital, Munich, Germany
| |
Collapse
|
33
|
Rübenthaler J, Bogner F, Reiser M, Clevert DA. Contrast-Enhanced Ultrasound (CEUS) of the Kidneys by Using the Bosniak Classification. Ultraschall Med 2016; 37:234-251. [PMID: 27058636 DOI: 10.1055/s-0042-104646] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Ultrasound is the most used interdisciplinary non-ionizing imaging technique in clinical routine. Therefore, ultrasound has a special value in the diagnosis and monitoring of cystic renal lesions, which can be classified as non-complicated or complicated and by means of occurrence as solitary or multifocal lesions. The Bosniak classification (I-IV) classifies renal cysts in 5 different categories with the help of ultrasound and computed tomography image criteria and is used for decisions of further clinical treatment. Additionally to normal native B-mode sonography, several new methods are in clinical use to improve diagnostic accuracy of unclear cases. Contrast enhanced ultrasound and MRI/CT are able to find and characterize difficult pathologies. This review explains the most important pathologies of cystic lesions of the kidney and stresses the different imaging methods of native B-mode sonography and the new techniques of contrast enhanced ultrasound.
Collapse
Affiliation(s)
- J Rübenthaler
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Großhadern Campus, Munich, Germany
| | - F Bogner
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Großhadern Campus, Munich, Germany
| | - M Reiser
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Großhadern Campus, Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, Ludwig-Maximilians-University of Munich-Großhadern Campus, Munich, Germany
| |
Collapse
|
34
|
Paprottka PM, Zengel P, Cyran CC, Ingrisch M, Nikolaou K, Reiser MF, Clevert DA. Evaluation of multimodality imaging using image fusion with ultrasound tissue elasticity imaging in an experimental animal model. Clin Hemorheol Microcirc 2016; 57:101-10. [PMID: 24577380 DOI: 10.3233/ch-141821] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. METHOD AND MATERIALS Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. RESULTS In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. CONCLUSION The comparison of ultrasound tissue elasticity imaging enables a secure differentiation between different tumor tissue areas in comparison to image fusion with MRI in our small study group. Therefore ultrasound tissue elasticity imaging might be used for fast detection of tumor response in the future whereas conventional grey scale imaging alone could not provide the additional information. By using standard, contrast-enhanced MRI images for reliable and reproducible slice positioning, the strongly user-dependent limitation of ultrasound tissue elasticity imaging may be overcome, especially for a comparison between baseline and follow-up measurements.
Collapse
Affiliation(s)
- P M Paprottka
- Department of Clinical Radiology, University of Munich, Munich, Germany
| | - P Zengel
- Institute for Ear, Nose and Throat Medicine, University of Munich, Munich, Germany
| | - C C Cyran
- Department of Clinical Radiology, University of Munich, Munich, Germany
| | - M Ingrisch
- Department of Clinical Radiology, University of Munich, Munich, Germany
| | - K Nikolaou
- Department of Clinical Radiology, University of Munich, Munich, Germany
| | - M F Reiser
- Department of Clinical Radiology, University of Munich, Munich, Germany
| | - D A Clevert
- Department of Clinical Radiology, University of Munich, Munich, Germany
| |
Collapse
|
35
|
Strobl FF, D'Anastasi M, Hinzpeter R, Franke PS, Trumm CG, Waggershauser T, Staehler M, Clevert DA, Reiser M, Graser A, Paprottka PM. Renal Pseudoaneurysms and Arteriovenous Fistulas as a Complication of Nephron-Sparing Partial Nephrectomy: Technical and Functional Outcomes of Patients Treated With Selective Microcoil Embolization During a Ten-Year Period. ROFO-FORTSCHR RONTG 2016; 188:188-94. [PMID: 26756934 DOI: 10.1055/s-0041-110136] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
PURPOSE The aim of this study was to evaluate the clinical and functional outcomes in patients who underwent selective interventional embolization of renal pseudoaneurysms or arteriovenous fistulas at our center. MATERIALS AND METHODS Our retrospective analysis included all consecutive patients who received selective transcatheter embolization of renal pseudoaneurysms or arteriovenous fistulas after partial nephrectomy in our department from January, 2003 to September, 2013. The technical and clinical success rate and functional outcome of every procedure was collected and analyzed. Furthermore, the change in renal parenchymal volume before and after embolization was determined in a subgroup. RESULTS A total of 1425 patients underwent partial nephrectomy at our hospital. Of these, 39 (2.7 %) were identified with a pseudoaneurysm or an arteriovenous fistula after partial nephrectomy. The diagnosis of the vascular lesions was made by means of biphasic CT or CEUS. Technical success by means of selective microcoil embolization was achieved in all 39 patients (100 %). Clinical success, defined as no need for further operation or nephrectomy during follow-up, was achieved in 35 of 39 patients (85.7 %). Renal function, as measured by eGFR before and after the intervention, did not change significantly. However, a mean loss of parenchymal volume of 25.2 % was observed in a subgroup. No major or minor complications were attributable to the embolization procedure. CONCLUSION Transcatheter embolization is a promising method for treating vascular complications which may occur after partial nephrectomy. We confirm the high success rate of this technique while discussing renal functional outcomes and potential safety aspects. KEY POINTS Arterial pseudoaneurysms and arteriovenous fistulas are rare but severe complications after partial nephrectomy. Selective microcoil embolization is a safe and effective kidney-preserving procedure for treating these complications. Embolization leads to a significant loss of renal parenchymal volume but not to a loss of renal function.
Collapse
Affiliation(s)
- F F Strobl
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - M D'Anastasi
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - R Hinzpeter
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - P S Franke
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - C G Trumm
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - T Waggershauser
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - M Staehler
- Department of Urology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - D A Clevert
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - M Reiser
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - A Graser
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - P M Paprottka
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| |
Collapse
|
36
|
Rübenthaler J, Lutz J, Reiser M, Clevert DA. [Title Page - Paraganglioma of the Head and Neck: Follow-Up of Interventional Procedures with CEUS]. Ultraschall Med 2015; 36:541-543. [PMID: 26841712 DOI: 10.1055/s-0035-1552392] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
37
|
Abstract
Accurate identification of the location of carcinoma in the prostate is essential for long-term therapeutic success, in particular for minimally invasive procedures. In recent years many new positive study results for prostate imaging have been reported which must be compared and evaluated and previous conservative assessments may need to be re-evaluated. In addition, combinations of different imaging techniques are increasingly being used in daily clinical routine. Due to technical advancements in sonographic imaging, such as elastography and contrast-enhanced ultrasound (CEUS), the detection rate of prostate cancer can be increased. An overview of the different imaging modalities and current literature are presented in this article.
Collapse
Affiliation(s)
- B Schlenker
- Urologische Klinik und Poliklinik des Klinikums der Universität München, Marchioninistraße 15, 81377, München, Deutschland,
| | | | | |
Collapse
|
38
|
Zimmermann H, Reiser M, Meimarakis G, Paprottka P, Clevert DA. [New Applications and Indications for Contrast-Enhanced Sonography in Endovascular Aortic Repair]. Zentralbl Chir 2015. [PMID: 26212620 DOI: 10.1055/s-0035-1546147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
After edovascular repair of infrarenal aortic aneurysms (EVAR) endoleaks may occur necessitating further therapy. Therefore a reliable method for follow-up imaging after EVAR for detection and control of endoleaks is of high importance. Contrast-enhanced sonography (CEUS) does not require the application of nephrotoxid contrast media and does not stress the patient. CEUS is increasingly used and enables a quick, non-invasive follow-up examination for patient after EVAR. In addition, interventions as therapy for endoleaks may be executed using ultrasound. Initial experience with CEUS-guided aortic stenting shows that the amount of contrast media as well as X-ray time may be reduced.
Collapse
Affiliation(s)
- H Zimmermann
- Institut für klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Deutschland
| | - M Reiser
- Institut für klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Deutschland
| | - G Meimarakis
- Abteilung für Gefäßchirurgie, Klinikum der Ludwig-Maximilians-Universität München, Deutschland
| | - P Paprottka
- Institut für klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Deutschland
| | - D A Clevert
- Institut für klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Deutschland
| |
Collapse
|
39
|
Rjosk-Dendorfer D, Reu S, Deak Z, Hetterich H, Kolben T, Reiser M, Clevert DA. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma. Clin Hemorheol Microcirc 2015; 58:115-25. [PMID: 25227197 DOI: 10.3233/ch-141884] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. MATERIALS AND METHODS From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (<2.0 cm or ≥2.0 cm). Two readers assessed sonoelastographic findings at 12.5 MHz using the tsukuba elasticity score and results of Doppler sonography using a score of 0, 1 or 2, depending on the degree of perfusion. RESULTS Among the 16 examined lesions 3 showed a round shape, 9 were ovoid and in 4 cases a macrolobulated appearance could be seen. No significant differences concerning Tsukuba-score depending on various shapes of fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). CONCLUSION The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.
Collapse
Affiliation(s)
- D Rjosk-Dendorfer
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - S Reu
- Institute of Pathology, Ludwig-Maximilians-University, Munich, Germany
| | - Z Deak
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - H Hetterich
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - T Kolben
- Department of Gynecology and Obstetrics, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - M Reiser
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| | - D A Clevert
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich, Germany
| |
Collapse
|
40
|
Trottmann M, Marcon J, Mai V, D'Anastasi M, Becker A, Stief C, Reiser M, Clevert DA. Characterization of splenogonadal fusion by contrast-enhanced ultrasound (CEUS) and elastography. Ultraschall Med 2015; 36:97-100. [PMID: 26060855 DOI: 10.1055/s-0034-1369759] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
41
|
Clevert DA, Gürtler VM, Meimarakis G, D'Anastasi M, Weidenhagen R, Reiser MF, Becker CR. Classification of endoleaks in the follow-up after EVAR using the time-to-peak of the contrast agent in CEUS examinations. Clin Hemorheol Microcirc 2014; 55:183-91. [PMID: 23455839 DOI: 10.3233/ch-131701] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the feasibility of the classification of endoleaks following endovascular aortic aneurysm repair using the time-to-peak of the contrast agent in CEUS examinations. MATERIAL AND METHODS In this retrospective study, a cohort of 171 patients with a total of 489 CEUS follow-up examinations after EVAR were included. In 254 of the 489 examinations, an endoleak was seen and the time-to-peak was measured in seconds. Existence of an endoleak was confirmed by CT as the gold standard. RESULTS We evaluated 254 CEUS video sequences showing an endoleak out of a total of 489 examinations. Kruskal-Wallis test revealed with p = 0.001 differences between the single endoleak types based on the time to peak. Correction after Bonferroni showed significant differences between type Ia compared to Ib and to IIa over inferior mesenteric artery (IMA) and IIa over lumbar artery (LA). There are also disparities between type Ib and type IIa IMA and type III, furthermore between type IIa IMA compared to IIa LA and type III as well as type IIa LA matched to type III. CONCLUSION CEUS is an important method for the follow-up after EVAR. The time-to-peak does not seem to be a useful additional feature in classifying endoleaks, although there are differences between the time-to-peak of the single endoleak types and it is possible to make an order of the different endoleak types referring to the mean values.
Collapse
Affiliation(s)
- D A Clevert
- Department for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich-Grosshadern, Munich, Germany
| | | | | | | | | | | | | |
Collapse
|
42
|
Abstract
CLINICAL/METHODICAL ISSUE Optimization of ultrasound guided interventional procedures of the liver and kidneys using new imaging methods. STANDARD RADIOLOGICAL METHODS Punctures, biopsies, drainage, intraoperative ultrasound, fusion, embolization in correlation with ultrasound and other imaging methods. METHODICAL INNOVATIONS Real-time-sonography, contrast-enhanced ultrasound (CEUS) and fusion for planning, monitoring and postinterventional control. PERFORMANCE The use of CEUS enables better detection, characterization and execution of interventional procedures. Fusion facilitates detection. ACHIEVEMENTS The CEUS procedure is superior for detection and characterization of smaller lesions in comparison to the B scan. Fusion enables the performance of difficult interventional procedures. PRACTICAL RECOMMENDATIONS The B scan is the standard imaging method but CEUS and fusion could be helpful for smaller lesions.
Collapse
Affiliation(s)
- D-A Clevert
- Institut für Klinische Radiologie, Klinikum der Ludwigs-Maximilian-Universität München, Campus Großhadern, München, Deutschland
| | | |
Collapse
|
43
|
Clevert DA. Kontrastmittelverstärkter Ultraschall im Follow-up nach endovaskulärer Stentversorgung des infrarenalen Bauchaortenaneurysmas. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
44
|
Clevert DA. Elastografie der Leber, ein neuer Weg der Diagnostik. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
45
|
Jung EM, Clevert DA. Bildfusion und Volumennavigation US/CEUS mti CT/MRT/PET. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
46
|
Clevert DA. CEUS in der vaskulären Diagnostik und bei Gefäßinterventionen. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
47
|
Zengel P, Schrötzlmair F, Reichel C, Paprottka P, Clevert DA. Sonography: the leading diagnostic tool for diseases of the salivary glands. Semin Ultrasound CT MR 2014; 34:196-203. [PMID: 23768886 DOI: 10.1053/j.sult.2012.11.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Ultrasound examination is the imaging procedure with the best predictive diagnostic capability for the salivary glands. Due to the salivary glands' relatively superficial anatomical location, clear boundary from surrounding tissue and comparatively typical echogenicity, therefore sonography is ideal for diagnosis. In addition, the technical advances in recent years, including higher resolution, color Doppler sonography, contrast-enhanced ultrasound, elastography, and tissue harmonic have lead to an improvement in diagnostic accuracy of sonography further resulting in an expansion of the range of indications. Sonography allows detection of obstructive salivary gland diseases such as stenosis or sialolithiasis, as well as sialadenosis such as Sjögren syndrome. Ultrasound examination alone is sufficient to diagnose benign tumors. However, in the case of malignant tumors, computer tomography or MRI may be also required, especially to determine the question of infiltration of the skull base.
Collapse
Affiliation(s)
- P Zengel
- Department of Otorhinolaryngology, Head and Neck Surgery, Grosshadern Medical Center, Ludwig Maximilians University of Munich, Germany.
| | | | | | | | | |
Collapse
|
48
|
Abstract
If a renal mass is suspected on clinical examination or ultrasound the finding has to be confirmed by cross-sectional imaging. Methods that are used include multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Also contrast-enhanced ultrasound has been successfully implemented in renal imaging and now plays a major role in the differentiation of benign from malignant renal masses. In expert hands it can be used to show very faint vascularization and subtle enhancement. The MDCT technique benefits from the recently introduced dual energy technology that allows superior characterization of renal masses in a single-phase examination, thereby greatly reducing radiation exposure. For young patients and persons allergic to iodine MRI should be used and it provides excellent soft tissue contrast and visualizes contrast enhancement kinetics in multiphase examinations.This article aims at giving a comprehensive overview of these different imaging modalities, their clinical indications and contraindications, as well as a description of imaging findings of various renal masses.
Collapse
Affiliation(s)
- D-A Clevert
- Institut für Klinische Radiologie, Klinikum der Universität München, Marchioninistraße 15, 81377 München, Deutschland
| | | | | | | | | |
Collapse
|
49
|
Trumm CG, Stahl R, Peller M, Clevert DA, Huber A, Reiser MF, Matzko M. [MRI for monitoring of high intensity focused ultrasound: current developments]. Radiologe 2013; 53:1001-8. [PMID: 24170287 DOI: 10.1007/s00117-012-2463-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
With respect to monitoring of high intensity focused ultrasound (HIFU), synonym focused ultrasound (FUS) treatment, magnetic resonance imaging (MRI) is characterized by several advantageous properties: the precise definition and morphological characterization of the target area (before and after the intervention), the real-time visualization of the treatment effect by thermal imaging (during the intervention) and in the sense of a stereotactic system, the 3-dimensional localization of the target lesion, planning of the target volume and assessment of the achieved ablation volume (before and during the intervention). Non-enhanced T2-weighted multislice MR images are acquired for planning of the intervention. For temperature monitoring (comprising thermometry and thermodosimetry), the temperature-dependent shift of proton resonance frequency (PRFS) is most frequently employed. This method is independent of the treated tissue type or thermally induced tissue changes and facilitates a relative measurement of the temperature change based on a reference value. Future MRI applications include diffusion-weighted MRI (DWI-MRI; for the intrainterventional estimation of treatment efficacy), dynamic contrast-enhanced MRI (DCE-MRI, for the prediction of the potential and assessment of the treatment effect achieved) and motion-corrected temperature monitoring (referenceless and multibaseline thermometry).
Collapse
Affiliation(s)
- C G Trumm
- Institut für Klinische Radiologie, Klinikum der Ludwig-Maximilians-Universität München, Campus Großhadern, Marchioninistr. 15, 81377, München, Deutschland,
| | | | | | | | | | | | | |
Collapse
|
50
|
Paprottka PM, Ingrisch M, Koelln A, Zengel P, Cyran CC, Nikolaou K, Reiser MF, Clevert DA. Comparison of consecutive bolus tracking and flash replenishment measurements for the assessment of tissue hemodynamics using contrast-enhanced ultrasound (CEUS) in an experimental human squamous cell carcinoma model. Clin Hemorheol Microcirc 2013; 52:107-14. [PMID: 22960296 DOI: 10.3233/ch-2012-1588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate "bolus-tracking" (BT) and "flash-replenishment" (FR) for the assessment of tissue hemodynamics by contrast-enhanced ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model. Since the underlying tissue is the same, strong correlations between parameter outcomes of both techniques are expected. METHODS AND MATERIALS Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 18 female athymic-nude-rats. After 10 days of subcutaneous tumour growth, bolus tracking and flash-replenishment measurements were performed consecutively in the same imaging plane in each rat after bolus-injection of SonoVue via the lateral tail vein using a high-end ultrasound system with a 15 MHz probe. Video-sequences were analysed with dedicated software (VueBox®, Bracco-Suisse®). From BT measurements, the parameters peak enhancement (PEBT), wash-in area-under-the-curve (Wi-AUCBT), mean transit time (MTTBT), wash-in-rate (WiRBT) and perfusion-index (Wi-PIBT) were derived; FR yielded estimates of relative-blood-volume (rBVFR), mean transit time MTTFR, relative blood flow rBFFR and wash-in rate Wi-RFR. RESULTS In all rats, BT and FR measurements could be completed successfully. Highly significant correlations were observed between rBVFR and PEBT, rBVFR and Wi-AUCBT, rBVFR and MTTBT, rBVFR and WiPIBT, MTTFR and MTTBT, rBFFR and PEBT, rBFFR and Wi-AUCBT, rBFFR and WiRBT, rBFFR and WiPIBT, WiRFR and PEBT, WiRFR and Wi-AUCBT, WiRFR and WiRBT and WiRFR and WiPIBT. CONCLUSION Whereas bolus tracking can be used in a wide range of modalities including CEUS, CT and MR, FR as a technique for the assessment of tissue hemodynamics is unique to CEUS. Although BT and FR yield different parameters, the underlying tissue hemodynamics are equal. In this work, we were able to demonstrate strong correlations between different parameters of both modalities in a small-animal-tumor-model, indicating that flash-replenishment is a valid alternative to the more established bolus-tracking technique. Although the lack of absolute, quantitative parameters hinders a direct comparison of both modalities, FR and BT should both be suitable for a relative comparison, e.g. between baseline and follow-up examinations.
Collapse
Affiliation(s)
- P M Paprottka
- Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Munich, Germany.
| | | | | | | | | | | | | | | |
Collapse
|