1
|
Marcazzan S, Braz Carvalho MJ, Nguyen NT, Strangmann J, Slotta-Huspenina J, Tenditnaya A, Tschurtschenthaler M, Rieder J, Proaño-Vasco A, Ntziachristos V, Steiger K, Gorpas D, Quante M, Kossatz S. PARP1-targeted fluorescence molecular endoscopy as novel tool for early detection of esophageal dysplasia and adenocarcinoma. J Exp Clin Cancer Res 2024; 43:53. [PMID: 38383387 PMCID: PMC10880256 DOI: 10.1186/s13046-024-02963-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 01/22/2024] [Indexed: 02/23/2024] Open
Abstract
BACKGROUND Esophageal cancer is one of the 10 most common cancers worldwide and its incidence is dramatically increasing. Despite some improvements, the current surveillance protocol with white light endoscopy and random untargeted biopsies collection (Seattle protocol) fails to diagnose dysplastic and cancerous lesions in up to 50% of patients. Therefore, new endoscopic imaging technologies in combination with tumor-specific molecular probes are needed to improve early detection. Herein, we investigated the use of the fluorescent Poly (ADP-ribose) Polymerase 1 (PARP1)-inhibitor PARPi-FL for early detection of dysplastic lesions in patient-derived organoids and transgenic mouse models, which closely mimic the transformation from non-malignant Barrett's Esophagus (BE) to invasive esophageal adenocarcinoma (EAC). METHODS We determined PARP1 expression via immunohistochemistry (IHC) in human biospecimens and mouse tissues. We also assessed PARPi-FL uptake in patient- and mouse-derived organoids. Following intravenous injection of 75 nmol PARPi-FL/mouse in L2-IL1B (n = 4) and L2-IL1B/IL8Tg mice (n = 12), we conducted fluorescence molecular endoscopy (FME) and/or imaged whole excised stomachs to assess PARPi-FL accumulation in dysplastic lesions. L2-IL1B/IL8Tg mice (n = 3) and wild-type (WT) mice (n = 2) without PARPi-FL injection served as controls. The imaging results were validated by confocal microscopy and IHC of excised tissues. RESULTS IHC on patient and murine tissue revealed similar patterns of increasing PARP1 expression in presence of dysplasia and cancer. In human and murine organoids, PARPi-FL localized to PARP1-expressing epithelial cell nuclei after 10 min of incubation. Injection of PARPi-FL in transgenic mouse models of BE resulted in the successful detection of lesions via FME, with a mean target-to-background ratio > 2 independently from the disease stage. The localization of PARPi-FL in the lesions was confirmed by imaging of the excised stomachs and confocal microscopy. Without PARPi-FL injection, identification of lesions via FME in transgenic mice was not possible. CONCLUSION PARPi-FL imaging is a promising approach for clinically needed improved detection of dysplastic and malignant EAC lesions in patients with BE. Since PARPi-FL is currently evaluated in a phase 2 clinical trial for oral cancer detection after topical application, clinical translation for early detection of dysplasia and EAC in BE patients via FME screening appears feasible.
Collapse
Affiliation(s)
- Sabrina Marcazzan
- II. Medizinische Klinik, TUM School of Medicine and Health, Klinikum Rechts der Isar at Technical University of Munich, Munich, 81675, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
- Clinical Radiology, Medical School OWL, Bielefeld University, Bielefeld, 33615, Germany
| | - Marcos J Braz Carvalho
- II. Medizinische Klinik, TUM School of Medicine and Health, Klinikum Rechts der Isar at Technical University of Munich, Munich, 81675, Germany
| | - Nghia T Nguyen
- Department of Nuclear Medicine, TUM School of Medicine and Health, Klinikum Rechts der Isar at Technical University of Munich, Munich, 81675, Germany
- Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
| | - Julia Strangmann
- Department of Medicine II (Gastroenterology, Hepatology, Endocrinology, and Infectious Diseases), Freiburg University Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, 79106, Germany
| | - Julia Slotta-Huspenina
- Institute of Pathology, TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
| | - Anna Tenditnaya
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
| | - Markus Tschurtschenthaler
- Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
- Division of Translational Cancer Research, German Cancer Research Center (DKFZ) and German Cancer Consortium (DKTK), Heidelberg, 69120, Germany
- Chair of Translational Cancer Research and Institute of Experimental Cancer Therapy, TUM School of Medicine and Health, Klinikum rechts der Isar at Technical University of Munich, Munich, 81675, Germany
| | - Jonas Rieder
- Department of Medicine II (Gastroenterology, Hepatology, Endocrinology, and Infectious Diseases), Freiburg University Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, 79106, Germany
| | - Andrea Proaño-Vasco
- Department of Medicine II (Gastroenterology, Hepatology, Endocrinology, and Infectious Diseases), Freiburg University Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, 79106, Germany
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
| | - Katja Steiger
- Institute of Pathology, TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
- Comparative Experimental Pathology (CEP) and IBioTUM tissue biobank, TUM School of Medicine and Health, Technical University of Munich, München, 81675, Germany
| | - Dimitris Gorpas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, 85764 Neuherberg, Germany and Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany
| | - Michael Quante
- Department of Medicine II (Gastroenterology, Hepatology, Endocrinology, and Infectious Diseases), Freiburg University Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, 79106, Germany.
| | - Susanne Kossatz
- Department of Nuclear Medicine, TUM School of Medicine and Health, Klinikum Rechts der Isar at Technical University of Munich, Munich, 81675, Germany.
- Central Institute for Translational Cancer Research (TranslaTUM), TUM School of Medicine and Health, Technical University of Munich, Munich, 81675, Germany.
- Department of Chemistry, TUM School of Natural Sciences, Technical University of Munich, Munich, 85748, Germany.
| |
Collapse
|
2
|
Arias A, Anastasopoulou M, Gorpas D, Ntziachristos V. Using reflectometry to minimize the dependence of fluorescence intensity on optical absorption and scattering. Biomed Opt Express 2023; 14:5499-5511. [PMID: 37854563 PMCID: PMC10581795 DOI: 10.1364/boe.496599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 09/11/2023] [Indexed: 10/20/2023]
Abstract
The total diffuse reflectance RT and the effective attenuation coefficient µeff of an optically diffuse medium map uniquely onto its absorption and reduced scattering coefficients. Using this premise, we developed a methodology where RT and the slope of the logarithmic spatially resolved reflectance, a quantity related to µeff, are the inputs of a look-up table to correct the dependence of fluorescent signals on the media's optical properties. This methodology does not require an estimation of the medium's optical property, avoiding elaborate simulations and their errors to offer accurate and fast corrections. The experimental demonstration of our method yielded a mean relative error in fluorophore concentrations of less than 4% over a wide range of optical property variations. We discuss how the method developed can be employed to improve image fidelity and fluorochrome quantification in fluorescence molecular imaging clinical applications.
Collapse
Affiliation(s)
- Augusto Arias
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, 81675, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, 85764, Germany
| | - Maria Anastasopoulou
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, 81675, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, 85764, Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, 81675, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, 85764, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, Munich, 81675, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, 85764, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, 81675, Germany
| |
Collapse
|
3
|
Sikkenk DJ, Sterkenburg AJ, Schmidt I, Gorpas D, Nagengast WB, Consten ECJ. Detection of Tumour-Targeted IRDye800CW Tracer with Commercially Available Laparoscopic Surgical Systems. Diagnostics (Basel) 2023; 13:diagnostics13091591. [PMID: 37174982 PMCID: PMC10178288 DOI: 10.3390/diagnostics13091591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/22/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023] Open
Abstract
(1) Introduction: Near-infrared fluorescence (NIRF) combined with tumour-targeted tracers, such as bevacizumab-800CW, could aid surgical decision-making. This study explored the use of IRDye800CW, conjugated to bevacizumab, with four commercially available NIRF laparoscopes optimised for indocyanine green (ICG). (2) Methods: A (lymph node) phantom was made from a calibration device for NIRF and tissue-mimicking material. Serial dilutions of bevacizumab-800CW were made and ICG functioned as a reference. System settings, working distance, and thickness of tissue-mimicking material were varied to assess visibility of the fluorescence signal and tissue penetration. Tests were performed with four laparoscopes: VISERA ELITE II, Olympus; IMAGE1 S™ 4U Rubina, KARL STORZ; ENDOCAM Logic 4K platform, Richard Wolf; da Vinci Xi, Intuitive Surgical. (3) Results: The lowest visible bevacizumab-800CW concentration ranged between 13-850 nM (8-512 times diluted stock solution) for all laparoscopes, but the tracer was not visible through 0.8 cm of tissue in all systems. In contrast, ICG was still visible at a concentration of 0.4 nM (16,384 times diluted) and through 1.6-2.4 cm of tissue. Visibility and tissue penetration generally improved with a reduced working distance and manually adjusted system settings. (4) Conclusion: Depending on the application, bevacizumab-800CW might be sufficiently visible with current laparoscopes, but optimisation would widen applicability of tumour-targeted IRDye800CW tracers.
Collapse
Affiliation(s)
- Daan J Sikkenk
- Department of Surgery, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
- Department of Surgery, Meander Medical Centre, Maatweg 3, 3813 TZ Amersfoort, The Netherlands
| | - Andrea J Sterkenburg
- Department of Gastroenterology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| | - Iris Schmidt
- Department of Gastroenterology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| | - Dimitris Gorpas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München (GmbH), Ingolstädter Landstraße 1, D-85764 Neuherberg, Germany
- Chair of Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Ismaninger Straße 22, D-81675 Munich, Germany
| | - Wouter B Nagengast
- Department of Gastroenterology, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
| | - Esther C J Consten
- Department of Surgery, University Medical Centre Groningen, University of Groningen, Hanzeplein 1, 9713 GZ Groningen, The Netherlands
- Department of Surgery, Meander Medical Centre, Maatweg 3, 3813 TZ Amersfoort, The Netherlands
| |
Collapse
|
4
|
Rauschendorfer P, Wissmeyer G, Jaffer FA, Gorpas D, Ntziachristos V. Accounting for blood attenuation in intravascular near-infrared fluorescence-ultrasound imaging using a fluorophore-coated guidewire. J Biomed Opt 2023; 28:046001. [PMID: 37035030 PMCID: PMC10073749 DOI: 10.1117/1.jbo.28.4.046001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 03/20/2023] [Indexed: 05/18/2023]
Abstract
Significance Intravascular near-infrared fluorescence (NIRF) imaging aims to improve the inspection of vascular pathology using fluorescent agents with specificity to vascular disease biomarkers. The method has been developed to operate in tandem with an anatomical modality, such as intravascular ultrasound (IVUS), and complements anatomical readings with pathophysiological contrast, enhancing the information obtained from the hybrid examination. Aim However, attenuation of NIRF signals by blood challenges NIRF quantification. We propose a new method for attenuation correction in NIRF intravascular imaging based on a fluorophore-coated guidewire that is used as a reference for the fluorescence measurement and provides a real-time measurement of blood attenuation during the NIRF examination. Approach We examine the performance of the method in a porcine coronary artery ex vivo and phantoms using a 3.2F NIRF-IVUS catheter. Results We demonstrate marked improvement over uncorrected signals of up to 4.5-fold and errors of < 11 % for target signals acquired at distances up to 1 mm from the catheter system employed. Conclusions The method offers a potential means of improving the accuracy of intravascular NIRF imaging under in vivo conditions.
Collapse
Affiliation(s)
- Philipp Rauschendorfer
- Technical University of Munich, Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
| | - Georg Wissmeyer
- Massachusetts General Hospital, Cardiovascular Research Center, Cardiology Division, Boston, Massachusetts, United States
| | - Farouc A. Jaffer
- Massachusetts General Hospital, Cardiovascular Research Center, Cardiology Division, Boston, Massachusetts, United States
- Massachusetts General Hospital, Wellman Center for Photomedicine, Boston, Massachusetts, United States
| | - Dimitris Gorpas
- Technical University of Munich, Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
| | - Vasilis Ntziachristos
- Technical University of Munich, Chair of Biological Imaging at the Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Munich, Germany
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
- Address all correspondence to Vasilis Ntziachristos,
| |
Collapse
|
5
|
Gabriels RY, van Heijst LE, Hooghiemstra WTR, van der Waaij AM, Kats-Ugurlu G, Karrenbeld A, Robinson DJ, Tenditnaya A, Ntziachristos V, Gorpas D, Nagengast WB. Detection of early esophageal neoplastic Barrett lesions with quantified fluorescence molecular endoscopy using cetuximab-800CW. J Nucl Med 2023; 64:803-808. [PMID: 36604181 DOI: 10.2967/jnumed.122.264656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 12/06/2022] [Accepted: 12/06/2022] [Indexed: 01/06/2023] Open
Abstract
Esophageal adenocarcinoma (EAC) causes 6 % of cancer-related deaths worldwide. Near-infrared fluorescence molecular endoscopy (NIR-FME) uses a tracer that targets overexpressed proteins. In this study we aim to investigate the feasibility of an epidermal growth factor receptor (EGFR) targeted tracer, cetuximab-800CW, to improve detection of early-stage EAC. Methods: We validated EGFR expression in 73 esophageal tissue sections. Subsequently, we topically administered cetuximab-800CW and performed high-definition white-light endoscopy (HD-WLE), narrow band imaging (NBI) and NIR-FME in fifteen patients with Barrett's esophagus (BE). Intrinsic fluorescence values were quantified using multi-diameter single fiber reflectance (MDSFR) and single-fiber fluorescence (SFF) spectroscopy. Back-table imaging, histopathological examination and EGFR immunohistochemistry on biopsies collected during NIR-FME procedures were performed and compared to in vivo imaging results. Results: Immunohistochemical pre-analysis showed high EGFR expression in 67% of dysplastic tissue sections. NIR-FME visualized all 12 HD-WLE visible lesions and 5 HD-WLE invisible dysplastic lesions, with increased fluorescence signal in visible dysplastic BE lesions compared to non-dysplastic BE as shown by MDSFR/SFF, reflecting a target-to-background ratio (TBR) of 1.5. Invisible dysplastic lesions also showed increased fluorescence with a TBR of 1.67. Immunohistochemistry analysis showed EGFR overexpression in 16 out of 17 (94%) dysplastic BE lesions, which all showed fluorescence signal. Conclusion: This study has shown that NIR-FME using cetuximab-800CW can improve detection of dysplastic lesions missed by HD-WLE and NBI.
Collapse
Affiliation(s)
- Ruben Y Gabriels
- Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Lisanne E van Heijst
- Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Wouter T R Hooghiemstra
- Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Anne M van der Waaij
- Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Gursah Kats-Ugurlu
- Department of Pathology and Medical Biology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Arend Karrenbeld
- Department of Pathology and Medical Biology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| | - Dominic J Robinson
- Center for Optic Diagnostics and Therapy, Otolaryngology, Erasmus University Medical Center, Rotterdam, Netherlands, Netherlands
| | - Anna Tenditnaya
- Technical University of Munich, Central Institute for Translational Cancer Research (TranslaTUM), Germany
| | - Vasilis Ntziachristos
- Technical University of Munich, Central Institute for Translational Cancer Research (TranslaTUM), Germany
| | - Dimitris Gorpas
- Technical University of Munich, Central Institute for Translational Cancer Research (TranslaTUM), Germany
| | - Wouter B Nagengast
- Department of Gastroenterology and Hepatology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands, Netherlands
| |
Collapse
|
6
|
Seguchi M, Aytekin A, Lenz T, Nicol P, Klosterman GR, Beele A, Sabic E, Utsch L, Alyaqoob A, Gorpas D, Ntziachristos V, Jaffer FA, Rauschendorfer P, Joner M. Intravascular molecular imaging: translating pathophysiology of atherosclerosis into human disease conditions. Eur Heart J Cardiovasc Imaging 2022; 24:e1-e16. [PMID: 36002376 DOI: 10.1093/ehjci/jeac163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 07/31/2022] [Indexed: 12/25/2022] Open
Abstract
Progression of atherosclerotic plaque in coronary arteries is characterized by complex cellular and non-cellular molecular interactions. Within recent years, atherosclerosis has been recognized as inflammation-driven disease condition, where progressive stages are characterized by morphological changes in plaque composition but also relevant molecular processes resulting in increased plaque vulnerability. While existing intravascular imaging modalities are able to resolve key morphological features during plaque progression, they lack capability to characterize the molecular profile of advanced atherosclerotic plaque. Because hybrid imaging modalities may provide incremental information related to plaque biology, they are expected to provide synergistic effects in detecting high risk patients and lesions. The aim of this article is to review existing literature on intravascular molecular imaging approaches, and to provide clinically oriented proposals of their application. In addition, we assembled an overview of future developments in this field geared towards detection of patients at risk for cardiovascular events.
Collapse
Affiliation(s)
- Masaru Seguchi
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Alp Aytekin
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Tobias Lenz
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Philipp Nicol
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Grace R Klosterman
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Alicia Beele
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Emina Sabic
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Léa Utsch
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Aseel Alyaqoob
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging and TranslaTUM, Technical University of Munich, Munich 80333, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum München GmbH, Neuherberg 85764, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging and TranslaTUM, Technical University of Munich, Munich 80333, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum München GmbH, Neuherberg 85764, Germany.,Deutsches Zentrum für Herz- und Kreislauf-Forschung (DZHK) e.V. (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich 80336, Germany
| | - Farouc A Jaffer
- Cardiovascular Research Center, Cardiology Division, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Philipp Rauschendorfer
- Chair of Biological Imaging and TranslaTUM, Technical University of Munich, Munich 80333, Germany.,Institute of Biological and Medical Imaging, Helmholtz Zentrum München GmbH, Neuherberg 85764, Germany.,Deutsches Zentrum für Herz- und Kreislauf-Forschung (DZHK) e.V. (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich 80336, Germany
| | - Michael Joner
- Klinik für Herz- und Kreislauferkrankungen, Deutsches Herzzentrum München, Technical University Munich, Munich 80636, Germany.,Deutsches Zentrum für Herz- und Kreislauf-Forschung (DZHK) e.V. (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich 80336, Germany
| |
Collapse
|
7
|
Gorpas D, Wabnitz H, Pfefer TJ. Special Section Guest Editorial: Tissue Phantoms to Advance Biomedical Optical Systems. J Biomed Opt 2022; 27:074701. [PMID: 35752879 PMCID: PMC9234512 DOI: 10.1117/1.jbo.27.7.074701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The editorial introduces the JBO Special Section on Tissue Phantoms to Advance Biomedical Optical Systems.
Collapse
Affiliation(s)
- Dimitris Gorpas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Technical University of Munich, Chair of Biological Imaging, Munich, Germany
| | - Heidrun Wabnitz
- Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
| | - T Joshua Pfefer
- Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
8
|
Zhao X, Gabriëls RY, Hooghiemstra WTR, Koller M, Meersma GJ, Buist-Homan M, Visser L, Robinson DJ, Tenditnaya A, Gorpas D, Ntziachristos V, Karrenbeld A, Kats-Ugurlu G, Fehrmann RSN, Nagengast WB. Validation of Novel Molecular Imaging Targets Identified by Functional Genomic mRNA Profiling to Detect Dysplasia in Barrett's Esophagus. Cancers (Basel) 2022; 14:cancers14102462. [PMID: 35626066 PMCID: PMC9139936 DOI: 10.3390/cancers14102462] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 05/06/2022] [Accepted: 05/13/2022] [Indexed: 02/01/2023] Open
Abstract
Barrett’s esophagus (BE) is the precursor of esophageal adenocarcinoma (EAC). Dysplastic BE (DBE) has a higher progression risk to EAC compared to non-dysplastic BE (NDBE). However, the miss rates for the endoscopic detection of DBE remain high. Fluorescence molecular endoscopy (FME) can detect DBE and mucosal EAC by highlighting the tumor-specific expression of proteins. This study aimed to identify target proteins suitable for FME. Publicly available RNA expression profiles of EAC and NDBE were corrected by functional genomic mRNA (FGmRNA) profiling. Following a class comparison between FGmRNA profiles of EAC and NDBE, predicted, significantly upregulated genes in EAC were prioritized by a literature search. Protein expression of prioritized genes was validated by immunohistochemistry (IHC) on DBE and NDBE tissues. Near-infrared fluorescent tracers targeting the proteins were developed and evaluated ex vivo on fresh human specimens. In total, 1976 overexpressed genes were identified in EAC (n = 64) compared to NDBE (n = 66) at RNA level. Prioritization and IHC validation revealed SPARC, SULF1, PKCι, and DDR1 (all p < 0.0001) as the most attractive imaging protein targets for DBE detection. Newly developed tracers SULF1-800CW and SPARC-800CW both showed higher fluorescence intensity in DBE tissue compared to paired non-dysplastic tissue. This study identified SPARC, SULF1, PKCι, and DDR1 as promising targets for FME to differentiate DBE from NDBE tissue, for which SULF1-800CW and SPARC-800CW were successfully ex vivo evaluated. Clinical studies should further validate these findings.
Collapse
Affiliation(s)
- Xiaojuan Zhao
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
- Cancer Research Center Groningen, Department of Medical Oncology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands;
| | - Ruben Y. Gabriëls
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
| | - Wouter T. R. Hooghiemstra
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
- Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
| | - Marjory Koller
- Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands;
| | - Gert Jan Meersma
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
- Cancer Research Center Groningen, Department of Medical Oncology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands;
| | - Manon Buist-Homan
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
- Department of Laboratory Medicine, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
| | - Lydia Visser
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.V.); (A.K.); (G.K.-U.)
| | - Dominic J. Robinson
- Center for Optic Diagnostics and Therapy, Erasmus University Medical Center, 3015 GD Rotterdam, The Netherlands;
| | - Anna Tenditnaya
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 80333 Munich, Germany; (A.T.); (D.G.); (V.N.)
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München (GmbH), 85764 Neuherberg, Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 80333 Munich, Germany; (A.T.); (D.G.); (V.N.)
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München (GmbH), 85764 Neuherberg, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine, Technical University of Munich, 80333 Munich, Germany; (A.T.); (D.G.); (V.N.)
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München (GmbH), 85764 Neuherberg, Germany
| | - Arend Karrenbeld
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.V.); (A.K.); (G.K.-U.)
| | - Gursah Kats-Ugurlu
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.V.); (A.K.); (G.K.-U.)
| | - Rudolf S. N. Fehrmann
- Cancer Research Center Groningen, Department of Medical Oncology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands;
| | - Wouter B. Nagengast
- Department of Gastroenterology and Hepatology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (X.Z.); (R.Y.G.); (W.T.R.H.); (G.J.M.); (M.B.-H.)
- Correspondence: ; Tel.: +31-(50)-361-6161
| |
Collapse
|
9
|
Sterkenburg AJ, Hooghiemstra WTR, Schmidt I, Ntziachristos V, Nagengast WB, Gorpas D. Standardization and implementation of fluorescence molecular endoscopy in the clinic. J Biomed Opt 2022; 27:JBO-210302SS-PERR. [PMID: 35170264 PMCID: PMC8847121 DOI: 10.1117/1.jbo.27.7.074704] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 01/19/2022] [Indexed: 05/26/2023]
Abstract
SIGNIFICANCE Near-infrared fluorescence molecular endoscopy (NIR-FME) is an innovative technique allowing for in vivo visualization of molecular processes in hollow organs. Despite its potential for clinical translation, NIR-FME still faces challenges, for example, the lack of consensus in performing quality control and standardization of procedures and systems. This may hamper the clinical approval of the technology by authorities and its acceptance by endoscopists. Until now, several clinical trials using NIR-FME have been performed. However, most of these trials had different study designs, making comparison difficult. AIM We describe the need for standardization in NIR-FME, provide a pathway for setting up a standardized clinical study, and describe future perspectives for NIR-FME. Body: Standardization is challenging due to many parameters. Invariable parameters refer to the hardware specifications. Variable parameters refer to movement or tissue optical properties. Phantoms can be of aid when defining the influence of these variables or when standardizing a procedure. CONCLUSION There is a need for standardization in NIR-FME and hurdles still need to be overcome before a widespread clinical implementation of NIR-FME can be realized. When these hurdles are overcome, clinical outcomes can be compared and systems can be benchmarked, enabling clinical implementation.
Collapse
Affiliation(s)
- Andrea J. Sterkenburg
- University of Groningen, University Medical Center Groningen, Department of Gastroenterology and Hepatology, Groningen, The Netherlands
| | - Wouter T. R. Hooghiemstra
- University of Groningen, University Medical Center Groningen, Department of Gastroenterology and Hepatology, Groningen, The Netherlands
| | - Iris Schmidt
- University of Groningen, University Medical Center Groningen, Department of Gastroenterology and Hepatology, Groningen, The Netherlands
| | - Vasilis Ntziachristos
- Technical University of Munich, School of Medicine, Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), Munich, Germany
- Helmholtz Zentrum München (GmbH), Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Wouter B. Nagengast
- University of Groningen, University Medical Center Groningen, Department of Gastroenterology and Hepatology, Groningen, The Netherlands
| | - Dimitris Gorpas
- Technical University of Munich, School of Medicine, Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), Munich, Germany
- Helmholtz Zentrum München (GmbH), Institute of Biological and Medical Imaging, Neuherberg, Germany
| |
Collapse
|
10
|
Marcazzan S, Braz Carvalho MJ, Konrad M, Strangmann J, Tenditnaya A, Baumeister T, Schmid RM, Wester HJ, Ntziachristos V, Gorpas D, Wang TC, Schottelius M, Quante M. CXCR4 peptide-based fluorescence endoscopy in a mouse model of Barrett's esophagus. EJNMMI Res 2022; 12:2. [PMID: 35006394 PMCID: PMC8748556 DOI: 10.1186/s13550-021-00875-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 12/24/2021] [Indexed: 12/14/2022] Open
Abstract
Background Near-infrared (NIR) fluorescence imaging has been emerging as a promising strategy to overcome the high number of early esophageal adenocarcinomas missed by white light endoscopy and random biopsy collection. We performed a preclinical assessment of fluorescence imaging and endoscopy using a novel CXCR4-targeted fluorescent peptide ligand in the L2-IL1B mouse model of Barrett’s esophagus. Methods Six L2-IL1B mice with advanced stage of disease (12–16 months old) were injected with the CXCR4-targeted, Sulfo-Cy5-labeled peptide (MK007), and ex vivo wide-field imaging of the whole stomach was performed 4 h after injection. Before ex vivo imaging, fluorescence endoscopy was performed in three L2-IL1B mice (12–14 months old) by a novel imaging system with two L2-IL1B mice used as negative controls. Results Ex vivo imaging and endoscopy in L2-IL1B mice showed that the CXCR4-targeted MK007 accumulated mostly in the dysplastic lesions with a mean target-to-background ratio > 2. The detection of the Sulfo-Cy5 signal in dysplastic lesions and its co-localization with CXCR4 stained cells by confocal microscopy further confirmed the imaging results. Conclusions This preliminary preclinical study shows that CXCR4-targeted fluorescence endoscopy using MK007 can detect dysplastic lesions in a mouse model of Barrett’s esophagus. Further investigations are needed to assess its use in the clinical setting. Supplementary Information The online version contains supplementary material available at 10.1186/s13550-021-00875-7.
Collapse
Affiliation(s)
- Sabrina Marcazzan
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany.,Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany.,Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany.,Christian Doppler Laboratory for Viral Immunotherapy of Cancer, Medical University of Innsbruck, Peter-Mayr-Straße 4b, 6020, Innsbruck, Austria
| | - Marcos J Braz Carvalho
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany
| | - Matthias Konrad
- Institut für Pharmazeutische Radiochemie, Technische Universität München, Munich, Germany
| | - Julia Strangmann
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany.,Innere Medizin II, Universitätsklinik Freiburg, Universität Freiburg, Freiburg im Breisgau, Germany
| | - Anna Tenditnaya
- Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany.,Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Theresa Baumeister
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany
| | - Roland M Schmid
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany
| | - Hans-Jürgen Wester
- Institut für Pharmazeutische Radiochemie, Technische Universität München, Munich, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany.,Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany.,Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Timothy C Wang
- Division of Digestive and Liver Diseases, Columbia University Irving Medical Center, New York, NY, USA
| | - Margret Schottelius
- Institut für Pharmazeutische Radiochemie, Technische Universität München, Munich, Germany.,Translational Radiopharmaceutical Sciences, Departments of Nuclear Medicine and Oncology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Michael Quante
- II Medizinische Klinik, Klinikum rechts der isar, Technische Universität München, Munich, Germany. .,Innere Medizin II, Universitätsklinik Freiburg, Universität Freiburg, Freiburg im Breisgau, Germany.
| |
Collapse
|
11
|
Fang HY, Stangl S, Marcazzan S, Carvalho MJB, Baumeister T, Anand A, Strangmann J, Huspenina JS, Wang TC, Schmid RM, Feith M, Friess H, Ntziachristos V, Multhoff G, Gorpas D, Quante M. Targeted Hsp70 fluorescence molecular endoscopy detects dysplasia in Barrett's esophagus. Eur J Nucl Med Mol Imaging 2022; 49:2049-2063. [PMID: 34882260 PMCID: PMC9016004 DOI: 10.1007/s00259-021-05582-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 10/03/2021] [Indexed: 01/21/2023]
Abstract
PURPOSE The incidence of esophageal adenocarcinoma (EAC) has been increasing for decades without significant improvements in treatment. Barrett's esophagus (BE) is best established risk factor for EAC, but current surveillance with random biopsies cannot predict progression to cancer in most BE patients due to the low sensitivity and specificity of high-definition white light endoscopy. METHODS Here, we evaluated the membrane-bound highly specific Hsp70-specific contrast agent Tumor-Penetrating Peptide (Hsp70-TPP) in guided fluorescence molecular endoscopy biopsy. RESULTS Hsp70 was significantly overexpressed as determined by IHC in dysplasia and EAC compared with non-dysplastic BE in patient samples (n = 12) and in high-grade dysplastic lesions in a transgenic (L2-IL1b) mouse model of BE. In time-lapse microscopy, Hsp70-TPP was rapidly taken up and internalized by human BE dysplastic patient-derived organoids. Flexible fluorescence endoscopy of the BE mouse model allowed a specific detection of Hsp70-TPP-Cy5.5 that corresponded closely with the degree of dysplasia but not BE. Ex vivo application of Hsp70-TPP-Cy5.5 to freshly resected whole human EAC specimens revealed a high (> 4) tumor-to-background ratio and a specific detection of previously undetected tumor infiltrations. CONCLUSION In summary, these findings suggest that Hsp70-targeted imaging using fluorescently labeled TPP peptide may improve tumor surveillance in BE patients.
Collapse
Affiliation(s)
- Hsin-Yu Fang
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Stefan Stangl
- Department of Radiation Oncology and Central Institute for Translational Cancer Research, (TranslaTUM), Technische Universität München, Munich, Germany
| | - Sabrina Marcazzan
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany ,Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany; Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Marcos J. Braz Carvalho
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Theresa Baumeister
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Akanksha Anand
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Julia Strangmann
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany ,Innere Medizin II, Universitätsklinik Freiburg, Universität Freiburg, Freiburg im Breisgau, Germany
| | | | - Timothy C. Wang
- Department of Medicine, Columbia University Irving Medical Center, New York, NY USA
| | - Roland M. Schmid
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Marcus Feith
- Chirurgische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Helmut Friess
- Chirurgische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany; Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Gabriele Multhoff
- Department of Radiation Oncology and Central Institute for Translational Cancer Research, (TranslaTUM), Technische Universität München, Munich, Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging, School of Medicine, Technische Universität München, Munich, Germany; Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Michael Quante
- II Medizinische Klinik, Klinikum Rechts Der Isar, Technische Universität München, Munich, Germany ,Innere Medizin II, Universitätsklinik Freiburg, Universität Freiburg, Freiburg im Breisgau, Germany
| |
Collapse
|
12
|
Liu N, O'Connor P, Gujrati V, Gorpas D, Glasl S, Blutke A, Walch A, Kleigrewe K, Sattler M, Plettenburg O, Ntziachristos V. Facile Synthesis of a Croconaine-Based Nanoformulation for Optoacoustic Imaging and Photothermal Therapy. Adv Healthc Mater 2021; 10:e2002115. [PMID: 33738974 DOI: 10.1002/adhm.202002115] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 02/05/2021] [Indexed: 12/13/2022]
Abstract
Near-infrared (NIR) light absorbing theranostic agents can integrate optoacoustic imaging and photothermal therapy for effective personalized precision medicine. However, most of these agents face the challenges of unstable optical properties, material-associated toxicity, and nonbiodegradability, all of which limit their biomedical application. Several croconaine-based organic agents able to overcome some of these limitations have been recently reported, but these suffer from complicated multistep synthesis protocols. Herein, the use of CR760, a croconaine dye with excellent optical properties, is reported for nanoparticle formulation and subsequent optoacoustic imaging and photothermal therapy. Importantly, CR760 can be conveniently prepared in a single step from commercially available materials. Furthermore, CR760 can be covalently attached, via a polyethylene glycol linker, to the αv β3 integrin ligand c(RGDyC), resulting in self-assembled nanoparticles (NPs) with cancer-targeting capability. Such CR760RGD-NPs exhibit strong NIR absorption, high photostability, high optoacoustic generation efficiency, and active tumor-targeting, making them ideal candidates for optoacoustic imaging. Due to favorable electron transfer, CR760RGD-NPs display a 45.37% photothermal conversion efficiency thereby rendering them additionally useful for photothermal therapy. Targeted tumor elimination, biosafety, and biocompatibility are demonstrated in a 4T1 murine breast tumor model. This work points to the use of CR760RGD-NPs as a promising nanoagent for NIR-based cancer phototheranostics.
Collapse
Affiliation(s)
- Nian Liu
- Chair of Biological Imaging Center for Translational Cancer Research (TranslaTUM) Technical University of Munich Munich 81675 Germany
- Institute of Biological and Medical Imaging Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Patrick O'Connor
- Institute of Medicinal Chemistry Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
- Institute of Structural Biology Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Vipul Gujrati
- Chair of Biological Imaging Center for Translational Cancer Research (TranslaTUM) Technical University of Munich Munich 81675 Germany
- Institute of Biological and Medical Imaging Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Dimitris Gorpas
- Chair of Biological Imaging Center for Translational Cancer Research (TranslaTUM) Technical University of Munich Munich 81675 Germany
- Institute of Biological and Medical Imaging Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Sarah Glasl
- Institute of Biological and Medical Imaging Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Andreas Blutke
- Research Unit Analytical Pathology Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Axel Walch
- Research Unit Analytical Pathology Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| | - Karin Kleigrewe
- Bavarian Center for Biomolecular Mass Spectrometry (BayBioMS) Technical University of Munich Freising 85354 Germany
| | - Michael Sattler
- Institute of Structural Biology Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
- Bavarian NMR Center and Center for Integrated Protein Science Munich Technical University of Munich Garching 85747 Germany
| | - Oliver Plettenburg
- Institute of Medicinal Chemistry Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
- Center for Biomolecular Research Institute of Organic Chemistry Leibniz Universität Hannover Hannover 30167 Germany
| | - Vasilis Ntziachristos
- Chair of Biological Imaging Center for Translational Cancer Research (TranslaTUM) Technical University of Munich Munich 81675 Germany
- Institute of Biological and Medical Imaging Helmholtz Zentrum München (GmbH) Neuherberg 85764 Germany
| |
Collapse
|
13
|
Gorpas D, Ntziachristos V, Tian J. Principles and Practice of Intraoperative Fluorescence Imaging. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00009-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
14
|
Varasteh Z, De Rose F, Mohanta S, Li Y, Zhang X, Miritsch B, Scafetta G, Yin C, Sager HB, Glasl S, Gorpas D, Habenicht AJ, Ntziachristos V, Weber WA, Bartolazzi A, Schwaiger M, D'Alessandria C. Imaging atherosclerotic plaques by targeting Galectin-3 and activated macrophages using ( 89Zr)-DFO- Galectin3-F(ab') 2 mAb. Am J Cancer Res 2021; 11:1864-1876. [PMID: 33408786 PMCID: PMC7778602 DOI: 10.7150/thno.50247] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Accepted: 11/11/2020] [Indexed: 12/12/2022] Open
Abstract
Rationale: The high expression of Galectin-3 (Gal3) in macrophages of atherosclerotic plaques suggests its participation in atherosclerosis pathogenesis, and raises the possibility to use it as a target to image disease severity in vivo. Here, we explored the feasibility of tracking atherosclerosis by targeting Gal3 expression in plaques of apolipoprotein E knockout (ApoE-KO) mice via PET imaging. Methods: Targeting of Gal3 in M0-, M1- and M2 (M2a/M2c)-polarized macrophages was assessed in vitro using a Gal3-F(ab')2 mAb labeled with AlexaFluor®488 and 89Zr- desferrioxamine-thioureyl-phenyl-isothiocyanate (DFO). To visualize plaques in vivo, ApoE-KO mice were injected i.v. with 89Zr-DFO-Gal3-F(ab')2 mAb and imaged via PET/CT 48 h post injection. Whole length aortas harvested from euthanized mice were processed for Sudan-IV staining, autoradiography, and immunostaining for Gal3, CD68 and α-SMA expression. To confirm accumulation of the tracer in plaques, ApoE-KO mice were injected i.v. with Cy5.5-Gal3-F(ab')2 mAb, euthanized 48 h post injection, followed by cryosections of the body and acquisition of fluorescent images. To explore the clinical potential of this imaging modality, immunostaining for Gal3, CD68 and α-SMA expression were carried out in human plaques. Single cell RNA sequencing (scRNA-Seq) analyses were performed to measure LGALS3 (i.e. a synonym for Gal3) gene expression in each macrophage of several subtypes present in murine or human plaques. Results: Preferential binding to M2 macrophages was observed with both AlexaFluor®488-Gal3-F(ab')2 and 89Zr-DFO-Gal3-F(ab')2 mAbs. Focal and specific 89Zr-DFO-Gal3-F(ab')2 mAb uptake was detected in plaques of ApoE-KO mice by PET/CT. Autoradiography and immunohistochemical analyses of aortas confirmed the expression of Gal3 within plaques mainly in macrophages. Moreover, a specific fluorescent signal was visualized within the lesions of vascular structures burdened by plaques in mice. Gal3 expression in human plaques showed similar Gal3 expression patterns when compared to their murine counterparts. Conclusions: Our data reveal that 89Zr-DFO-Gal3-F(ab')2 mAb PET/CT is a potentially novel tool to image atherosclerotic plaques at different stages of development, allowing knowledge-based tailored individual intervention in clinically significant disease.
Collapse
|
15
|
Aime S, Amirshaghaghi A, Angel PM, Ardenkjaer-Larsen JH, Atreya R, Awe S, Badea CT, Beekman FJ, Biade S, Borden MA, Brunsing RL, Chandrasekharan P, Chang JB, Chen F, Chen JW, Chen X, Cheng Z, Cheng Z, Cherin E, Clinthorne NH, Cohen J, Colson C, Conolly S, Contag CH, Cutler CS, Dayton PA, Devoogdt N, Dina O, Drake RR, Dubsky S, Ducongé F, Fellows BD, Foster FS, Francis KP, Fung BK, Gambhir SS, Gao R, Giovenzana GB, Goodwill P, Goorden MC, Gorpas D, Grimm J, Groll AN, Hargus S, Harmsen S, He S, Hensley D, Hutton BF, Huynh Q, Iagaru A, Josephson L, Jurisson SS, Keselman P, Kircher MF, Kokate T, Konkle J, Korsen JA, Krasniqi A, Laniyonu A, Levin CS, Lewis MR, Lewis JS, Liu G, Liu Y, Looger LL, Lu K, Lu Y, Lucignani G, Lyons SK, Maina T, Martelli C, Matheson AM, Mempel TR, Meng LJ, Moradi F, Nagle VL, Neurath MF, Nicolson F, Nie L, Ntziachristos V, Orendorff R, Ottobrini L, Ouyang Y, Paez Segala MG, Parraga G, Perez-Liva M, Pratt EC, Rao J, Rath T, Rodriguez E, Rosenthal EL, Ross BD, Saayujya C, Saritas EU, Scott DA, Sheth VR, Slagle C, Tamura R, Tavitian B, Tay ZW, Terreno E, Thakur M, Thompson C, Tian J, Travagin F, Tsourkas A, Tully KM, Usmani SM, VanBrocklin HF, van Keulen S, van Zijl PC, Walmer RW, Wang C, Wang J, Wang LV, Xavier C, Yao J, Yu EY, Zheng X, Zheng B, Zhou XY. Contributors. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.01002-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
16
|
Suprano A, Giordani T, Gianani I, Spagnolo N, Pinker K, Kupferman J, Arnon S, Klemm U, Gorpas D, Ntziachristos V, Sciarrino F. Propagation of structured light through tissue-mimicking phantoms. Opt Express 2020; 28:35427-35437. [PMID: 33379657 DOI: 10.1364/oe.402467] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Accepted: 10/03/2020] [Indexed: 06/12/2023]
Abstract
Optical interrogation of tissues is broadly considered in biomedical applications. Nevertheless, light scattering by tissue limits the resolution and accuracy achieved when investigating sub-surface tissue features. Light carrying optical angular momentum or complex polarization profiles, offers different propagation characteristics through scattering media compared to light with unstructured beam profiles. Here we discuss the behaviour of structured light scattered by tissue-mimicking phantoms. We study the spatial and the polarization profile of the scattered modes as a function of a range of optical parameters of the phantoms, with varying scattering and absorption coefficients and of different lengths. These results show the non-trivial trade-off between the advantages of structured light profiles and mode broadening, stimulating further investigations in this direction.
Collapse
|
17
|
Ruiz AJ, Wu M, LaRochelle EPM, Gorpas D, Ntziachristos V, Pfefer TJ, Pogue BW. Indocyanine green matching phantom for fluorescence-guided surgery imaging system characterization and performance assessment. J Biomed Opt 2020; 25:1-15. [PMID: 32441066 PMCID: PMC7240319 DOI: 10.1117/1.jbo.25.5.056003] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Accepted: 05/11/2020] [Indexed: 05/13/2023]
Abstract
SIGNIFICANCE Expanded use of fluorescence-guided surgery with devices approved for use with indocyanine green (ICG) has led to a range of commercial systems available. There is a compelling need to be able to independently characterize system performance and allow for cross-system comparisons. AIM The goal of this work is to expand on previous proposed fluorescence imaging standard designs to develop a long-term stable phantom that spectrally matches ICG characteristics and utilizes 3D printing technology for incorporating tissue-equivalent materials. APPROACH A batch of test targets was created to assess ICG concentration sensitivity in the 0.3- to 1000-nM range, tissue-equivalent depth sensitivity down to 6 mm, and spatial resolution with a USAF test chart. Comparisons were completed with a range of systems that have significantly different imaging capabilities and applications, including the Li-Cor® Odyssey, Li-Cor® Pearl, PerkinElmer® Solaris, and Stryker® Spy Elite. RESULTS Imaging of the ICG-matching phantoms with all four commercially available systems showed the ability to benchmark system performance and allow for cross-system comparisons. The fluorescence tests were able to assess differences in the detectable concentrations of ICG with sensitivity differences >10× for preclinical and clinical systems. Furthermore, the tests successfully assessed system differences in the depth-signal decay rate, as well as resolution performance and image artifacts. The manufacturing variations, photostability, and mechanical design of the tests showed promise in providing long-term stable standards for fluorescence imaging. CONCLUSIONS The presented ICG-matching phantom provides a major step toward standardizing performance characterization and cross-system comparisons for devices approved for use with ICG. The developed hybrid manufacturing platform can incorporate long-term stable fluorescing agents with 3D printed tissue-equivalent material. Further, long-term testing of the phantom and refinements to the manufacturing process are necessary for future implementation as a widely adopted fluorescence imaging standard.
Collapse
Affiliation(s)
- Alberto J. Ruiz
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Address all correspondence to Alberto J. Ruiz, E-mail: ; Brian W. Pogue, E-mail:
| | - Mindy Wu
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
| | | | - Dimitris Gorpas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Munich, Germany
- Technical University Munich, Helmholtz Zentrum Munich, Munich, Germany
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Munich, Germany
- Technical University Munich, Helmholtz Zentrum Munich, Munich, Germany
| | - T. Joshua Pfefer
- U.S. Food and Drug Administration, Center for Devices and Radiological Health, Rockville, Maryland, United States
| | - Brian W. Pogue
- Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
- Geisel School of Medicine, Department of Surgery, Hanover, New Hampshire, United States
- Address all correspondence to Alberto J. Ruiz, E-mail: ; Brian W. Pogue, E-mail:
| |
Collapse
|
18
|
Rogalla S, Flisikowski K, Gorpas D, Mayer AT, Flisikowska T, Mandella MJ, Ma X, Casey KM, Felt SA, Saur D, Ntziachristos V, Schnieke A, Contag CH, Gambhir SS, Harmsen S. Biodegradable fluorescent nanoparticles for endoscopic detection of colorectal carcinogenesis. Adv Funct Mater 2019; 29:1904992. [PMID: 33041743 PMCID: PMC7546531 DOI: 10.1002/adfm.201904992] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Early and comprehensive endoscopic detection of colonic dysplasia - the most clinically significant precursor lesion to colorectal adenocarcinoma - provides an opportunity for timely, minimally-invasive intervention to prevent malignant transformation. Here, the development and evaluation of biodegradable near-infrared fluorescent silica nanoparticles (FSN) is described that have the potential to improve adenoma detection during fluorescence-assisted white-light colonoscopic surveillance in rodent and human-scale models of colorectal carcinogenesis. FSNs are biodegradable (t1/2 of 2.7 weeks), well-tolerated, and enable detection and delineation of adenomas as small as 0.5 mm2 with high tumor-to-background ratios. Furthermore, in the human-scale, APC 1311/+ porcine model, the clinical feasibility and benefit of using FSN-guided detection of colorectal adenomas using video-rate fluorescence-assisted white-light endoscopy is demonstrated. Since nanoparticles of similar size (e.g., 100-150-nm) or composition (i.e., silica, silica/gold hybrid) have already been successfully translated to the clinic, and, clinical fluorescent/white light endoscopy systems are becoming more readily available, there is a viable path towards clinical translation of the proposed strategy for early colorectal cancer detection and prevention in high-risk patients.
Collapse
Affiliation(s)
- Stephan Rogalla
- Molecular Imaging Program at Stanford University (MIPS), Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA
- Department of Medicine (Gastroenterology & Hepatology), Stanford University School of Medicine, Stanford, CA 94305, USA
| | - Krzysztof Flisikowski
- Chair of Livestock Biotechnology, Technische Universität München, Liesel-Beckmann Str. 1, D-85354 Freising, Germany
| | - Dimitris Gorpas
- Helmholtz Zentrum München, German Researcg Center for Environmental Health, Institute of Biological and Medical Imaging, Ingolstädter Landstr. 1, D-85764, Neuherberg, Germany
- Chair of Biological Imaging, TranslaTUM, Technische Universität München, Einsteinstr. 25, 81675, München, Germany
| | - Aaron T. Mayer
- Molecular Imaging Program at Stanford University (MIPS), Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA
- Department of Bioengineering, Department of Materials Science & Engineering, Stanford University, Stanford, CA 94305, USA
| | - Tatiana Flisikowska
- Chair of Livestock Biotechnology, Technische Universität München, Liesel-Beckmann Str. 1, D-85354 Freising, Germany
| | - Michael J. Mandella
- Molecular Imaging Program at Stanford University (MIPS), Department of Radiology, Stanford University School of Medicine, Stanford, CA 94305, USA
- Institute for Quantitative Health Science and Engineering, Department of Biomedical Engineering, Michigan State University, 775 Woodlot Dr., East Lansing, MI 48824, USA
| | - Xiaopeng Ma
- Helmholtz Zentrum München, German Researcg Center for Environmental Health, Institute of Biological and Medical Imaging, Ingolstädter Landstr. 1, D-85764, Neuherberg, Germany
- Chair of Biological Imaging, TranslaTUM, Technische Universität München, Einsteinstr. 25, 81675, München, Germany
| | - Kerriann M. Casey
- Department of Comparative Medicine, Stanford University School of Medicine, Stanford, CA 94305, USA
| | - Stephen A. Felt
- Department of Comparative Medicine, Stanford University School of Medicine, Stanford, CA 94305, USA
| | - Dieter Saur
- Department of Internal Medicine II, Klinikum Rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, München, Germany
| | - Vasilis Ntziachristos
- Helmholtz Zentrum München, German Researcg Center for Environmental Health, Institute of Biological and Medical Imaging, Ingolstädter Landstr. 1, D-85764, Neuherberg, Germany
- Chair of Biological Imaging, TranslaTUM, Technische Universität München, Einsteinstr. 25, 81675, München, Germany
| | - Angelika Schnieke
- Chair of Livestock Biotechnology, Technische Universität München, Liesel-Beckmann Str. 1, D-85354 Freising, Germany
| | - Christopher H. Contag
- Corresponding Authors: Prof. C. H. Contag , Prof. S. S. Gambhir , and Dr. S. Harmsen
| | - Sanjiv S. Gambhir
- Corresponding Authors: Prof. C. H. Contag , Prof. S. S. Gambhir , and Dr. S. Harmsen
| | - Stefan Harmsen
- Corresponding Authors: Prof. C. H. Contag , Prof. S. S. Gambhir , and Dr. S. Harmsen
| |
Collapse
|
19
|
Gorpas D, Koch M, Anastasopoulou M, Bozhko D, Klemm U, Nieberler M, Ntziachristos V. Multi-Parametric Standardization of Fluorescence Imaging Systems Based on a Composite Phantom. IEEE Trans Biomed Eng 2019; 67:185-192. [PMID: 30990172 DOI: 10.1109/tbme.2019.2910733] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Fluorescence molecular imaging (FMI) has emerged as a promising tool for surgical guidance in oncology, with one of the few remaining challenges being the ability to offer quality control and data referencing. This paper investigates the use of a novel composite phantom to correct and benchmark FMI systems. METHODS This paper extends on previous work by describing a phantom design that can provide a more complete assessment of FMI systems through quantification of dynamic range and determination of spatial illumination patterns for both reflectance and fluorescence imaging. Various performance metrics are combined into a robust and descriptive "system benchmarking score," enabling not only the comprehensive comparison of different systems, but also for the first time, correction of the acquired data. RESULTS We show that systems developed for targeted fluorescence imaging can achieve benchmarking scores of up to 70%, while clinically available systems optimized for indocyanine green are limited to 50%, mostly due to greater leakage of ambient and excitation illumination and lower resolution. The image uniformity can also be approximated and employed for image flat-fielding, an important milestone toward data referencing. In addition, we demonstrate composite phantom use in assessing the performance of a surgical microscope and of a raster-scan imaging system. CONCLUSION Our results suggest that the new phantom has the potential to support high-fidelity FMI through benchmarking and image correction. SIGNIFICANCE Standardization of the FMI is a necessary process for establishing good imaging practices in clinical environments and for enabling high-fidelity imaging across patients and multi-center imaging studies.
Collapse
|
20
|
Wang H, Willershäuser M, Karlas A, Gorpas D, Reber J, Ntziachristos V, Maurer S, Fromme T, Li Y, Klingenspor M. A dual Ucp1 reporter mouse model for imaging and quantitation of brown and brite fat recruitment. Mol Metab 2019; 20:14-27. [PMID: 30580967 PMCID: PMC6358570 DOI: 10.1016/j.molmet.2018.11.009] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 11/21/2018] [Accepted: 11/23/2018] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES Brown adipose tissue (BAT) dissipates nutritional energy as heat through uncoupling protein 1 (UCP1). The discovery of functional BAT in healthy adult humans has promoted the search for pharmacological interventions to recruit and activate brown fat as a treatment of obesity and diabetes type II. These efforts require in vivo models to compare the efficacy of novel compounds in a relevant physiological context. METHODS We generated a knock-in mouse line expressing firefly luciferase and near-infrared red florescent protein (iRFP713) driven by the regulatory elements of the endogenous Ucp1 gene. RESULTS Our detailed characterization revealed that firefly luciferase activity faithfully reports endogenous Ucp1 gene expression in response to physiological and pharmacological stimuli. The iRFP713 fluorescence signal was detected in the interscapular BAT region of cold-exposed reporter mice in an allele-dosage dependent manner. Using this reporter mouse model, we detected a higher browning capacity in female peri-ovarian white adipose tissue compared to male epididymal WAT, which we further corroborated by molecular and morphological features. In situ imaging detected a strong luciferase activity signal in a previously unappreciated adipose tissue depot adjunct to the femoral muscle, now adopted as femoral brown adipose tissue. In addition, screening cultured adipocytes by bioluminescence imaging identified the selective Salt-Inducible Kinase inhibitor, HG-9-91-01, to increase Ucp1 gene expression and mitochondrial respiration in brown and brite adipocytes. CONCLUSIONS In our mouse model, firefly luciferase activity serves as a bona fide reporter for dynamic regulation of Ucp1. In addition, by means of iRFP713 we are able to monitor Ucp1 expression in a non-invasive fashion.
Collapse
Affiliation(s)
- Hui Wang
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany
| | - Monja Willershäuser
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany
| | - Angelos Karlas
- Chair for Biological Imaging, Technical University of Munich, Troger Str. 9, 81675 München, Germany
| | - Dimitris Gorpas
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Ingolstädter Landstr.1, 85764 Neuherberg, Germany; Chair for Biological Imaging, Technical University of Munich, Troger Str. 9, 81675 München, Germany
| | - Josefine Reber
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Ingolstädter Landstr.1, 85764 Neuherberg, Germany
| | - Vasilis Ntziachristos
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Ingolstädter Landstr.1, 85764 Neuherberg, Germany; Chair for Biological Imaging, Technical University of Munich, Troger Str. 9, 81675 München, Germany
| | - Stefanie Maurer
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany
| | - Tobias Fromme
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany
| | - Yongguo Li
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany
| | - Martin Klingenspor
- EKFZ - Else Kröner-Fresenius Zentrum for Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany; Chair for Molecular Nutritional Medicine, Technical University of Munich, Gregor-Mendel-Str. 2, 85354 Freising, Germany.
| |
Collapse
|
21
|
Napp J, Markus MA, Heck JG, Dullin C, Möbius W, Gorpas D, Feldmann C, Alves F. Therapeutic Fluorescent Hybrid Nanoparticles for Traceable Delivery of Glucocorticoids to Inflammatory Sites. Am J Cancer Res 2018; 8:6367-6383. [PMID: 30613305 PMCID: PMC6299685 DOI: 10.7150/thno.28324] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Accepted: 10/19/2018] [Indexed: 01/15/2023] Open
Abstract
Treatment of inflammatory disorders with glucocorticoids (GCs) is often accompanied by severe adverse effects. Application of GCs via nanoparticles (NPs), especially those using simple formulations, could possibly improve their delivery to sites of inflammation and therefore their efficacy, minimising the required dose and thus reducing side effects. Here, we present the evaluation of NPs composed of GC betamethasone phosphate (BMP) and the fluorescent dye DY-647 (BMP-IOH-NPs) for improved treatment of inflammation with simultaneous in vivo monitoring of NP delivery. Methods: BMP-IOH-NP uptake by MH-S macrophages was analysed by fluorescence and electron microscopy. Lipopolysaccharide (LPS)-stimulated cells were treated for 48 h with BMP-IOH-NPs (1×10-5-1×10-9 M), BMP or dexamethasone (Dexa). Drug efficacy was assessed by measurement of interleukin 6. Mice with Zymosan-A-induced paw inflammation were intraperitoneally treated with BMP-IOH-NPs (10 mg/kg) and mice with ovalbumin (OVA)-induced allergic airway inflammation (AAI) were treated intranasally with BMP-IOH-NPs, BMP or Dexa (each 2.5 mg/kg). Efficacy was assessed in vivo by paw volume measurements with µCT and ex vivo by measurement of paw weight for Zymosan-A-treated mice, or in the AAI model by in vivo x-ray-based lung function assessment and by cell counts in the bronchoalveolar lavage (BAL) fluid and histology. Delivery of BMP-IOH-NPs to the lungs of AAI mice was monitored by in vivo optical imaging and by fluorescence microscopy. Results: Uptake of BMP-IOH-NPs by MH-S cells was observed during the first 10 min of incubation, with the NP load increasing over time. The anti-inflammatory effect of BMP-IOH-NPs in vitro was dose dependent and higher than that of Dexa or free BMP, confirming efficient release of the drug. In vivo, Zymosan-A-induced paw inflammation was significantly reduced in mice treated with BMP-IOH-NPs. AAI mice that received BMP-IOH-NPs or Dexa but not BMP revealed significantly decreased eosinophil numbers in BALs and reduced immune cell infiltration in lungs. Correspondingly, lung function parameters, which were strongly affected in non-treated AAI mice, were unaffected in AAI mice treated with BMP-IOH-NPs and resembled those of healthy animals. Accumulation of BMP-IOH-NPs within the lungs of AAI mice was detectable by optical imaging for at least 4 h in vivo, where they were preferentially taken up by peribronchial and alveolar M2 macrophages. Conclusion: Our results show that BMP-IOH-NPs can effectively be applied in therapy of inflammatory diseases with at least equal efficacy as the gold standard Dexa, while their delivery can be simultaneously tracked in vivo by fluorescence imaging. BMP-IOH-NPs thus have the potential to reach clinical applications.
Collapse
|
22
|
Bozhko D, Karlas A, Gorpas D, Ntziachristos V. Optoacoustic sensing of hematocrit to improve the accuracy of hybrid fluorescence-ultrasound intravascular imaging. J Biophotonics 2018; 11:e201700255. [PMID: 29341467 DOI: 10.1002/jbio.201700255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 01/12/2018] [Indexed: 06/07/2023]
Abstract
Hybrid intravascular fluorescence-ultrasound imaging is emerging for reading anatomical and biological information in vivo. By operating through blood, intravascular near-infrared fluorescence (NIRF) detection is affected by hemoglobin attenuation. Improved quantification has been demonstrated with methods that correct for the attenuation of the optical signal as it propagates through blood. These methods assume an attenuation coefficient for blood and measure the distance between detector and the vessel wall by observing the intravascular ultrasound images. Assumptions behind the attenuation employed in correction models may reduce the accuracy of these methods. Herein, we explore a novel approach to dynamically estimate optical absorption by using optoacoustic (photoacoustic) measurements. Adaptive correction is based on a trimodal intravascular catheter that integrates fluorescence, ultrasound and optoacoustic measurements. Using the novel catheter, we show how optoacoustic measurements can determine variations of blood absorption, leading to accurate quantification of the detected NIRF signals at different hematocrit values.
Collapse
Affiliation(s)
- Dmitry Bozhko
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| | - Angelos Karlas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| | - Dimitris Gorpas
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| |
Collapse
|
23
|
Gorpas D, Davari P, Bec J, Fung MA, Marcu L, Farwell DG, Fazel N. Time-resolved fluorescence spectroscopy for the diagnosis of oral lichen planus. Clin Exp Dermatol 2018; 43:546-552. [DOI: 10.1111/ced.13404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/25/2017] [Indexed: 11/29/2022]
Affiliation(s)
- D. Gorpas
- Department of Biomedical Engineering; University of California-Davis; Davis CA USA
- Institute of Biological and Medical Imaging; Helmholtz Zentrum München; Neuherberg Germany
| | - P. Davari
- Department of Dermatology; Davis Medical Center; University of California-Davis; Sacramento CA USA
| | - J. Bec
- Department of Biomedical Engineering; University of California-Davis; Davis CA USA
| | - M. A. Fung
- Department of Dermatology; Davis Medical Center; University of California-Davis; Sacramento CA USA
| | - L. Marcu
- Department of Biomedical Engineering; University of California-Davis; Davis CA USA
| | - D. G. Farwell
- Department of Otolaryngology-Head and Neck Surgery; Davis Medical Center; University of California-Davis; Sacramento CA USA
| | - N. Fazel
- Department of Dermatology; Davis Medical Center; University of California-Davis; Sacramento CA USA
| |
Collapse
|
24
|
Phipps JE, Gorpas D, Unger J, Darrow M, Bold RJ, Marcu L. Automated detection of breast cancer in resected specimens with fluorescence lifetime imaging. Phys Med Biol 2017; 63:015003. [PMID: 29099721 PMCID: PMC7485302 DOI: 10.1088/1361-6560/aa983a] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Re-excision rates for breast cancer lumpectomy procedures are currently nearly 25% due to surgeons relying on inaccurate or incomplete methods of evaluating specimen margins. The objective of this study was to determine if cancer could be automatically detected in breast specimens from mastectomy and lumpectomy procedures by a classification algorithm that incorporated parameters derived from fluorescence lifetime imaging (FLIm). This study generated a database of co-registered histologic sections and FLIm data from breast cancer specimens (N = 20) and a support vector machine (SVM) classification algorithm able to automatically detect cancerous, fibrous, and adipose breast tissue. Classification accuracies were greater than 97% for automated detection of cancerous, fibrous, and adipose tissue from breast cancer specimens. The classification worked equally well for specimens scanned by hand or with a mechanical stage, demonstrating that the system could be used during surgery or on excised specimens. The ability of this technique to simply discriminate between cancerous and normal breast tissue, in particular to distinguish fibrous breast tissue from tumor, which is notoriously challenging for optical techniques, leads to the conclusion that FLIm has great potential to assess breast cancer margins. Identification of positive margins before waiting for complete histologic analysis could significantly reduce breast cancer re-excision rates.
Collapse
Affiliation(s)
- Jennifer E. Phipps
- University of California, Davis, Biomedical Engineering Department, 1 Shields Ave, Davis CA 95616
| | - Dimitris Gorpas
- University of California, Davis, Biomedical Engineering Department, 1 Shields Ave, Davis CA 95616
| | - Jakob Unger
- University of California, Davis, Biomedical Engineering Department, 1 Shields Ave, Davis CA 95616
| | - Morgan Darrow
- University of California Davis Health System, Department of Pathology and Laboratory Medicine
| | - Richard J. Bold
- University of California Davis Health System, Department of Surgery
| | - Laura Marcu
- University of California, Davis, Biomedical Engineering Department, 1 Shields Ave, Davis CA 95616
| |
Collapse
|
25
|
Fereidouni F, Gorpas D, Ma D, Fatakdawala H, Marcu L. Rapid fluorescence lifetime estimation with modified phasor approach and Laguerre deconvolution: a comparative study. Methods Appl Fluoresc 2017; 5:035003. [PMID: 28644150 PMCID: PMC6043162 DOI: 10.1088/2050-6120/aa7b62] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Fluorescence lifetime imaging has been shown to serve as a valuable tool for interrogating and diagnosis of biological tissue at a mesoscopic level. The ability to analyze fluorescence decay curves to extract lifetime values in real-time is crucial for clinical translation and applications such as tumor margin delineation or intracoronary imaging of atherosclerotic plaques. In this work, we compare the performance of two popular non-parametric (fit-free) methods for determining lifetime values from fluorescence decays in real-time-the Phasor approach and Laguerre deconvolution. We demonstrate results from simulated and experimental data to compare the accuracy and speed of both methods and their dependence on noise and model parameters.
Collapse
Affiliation(s)
- Farzad Fereidouni
- Department of Pathology and Laboratory Medicine, 4400 V Street, CA 95817, United States of America
| | | | | | | | | |
Collapse
|
26
|
Bec J, Phipps JE, Gorpas D, Ma D, Fatakdawala H, Margulies KB, Southard JA, Marcu L. In vivo label-free structural and biochemical imaging of coronary arteries using an integrated ultrasound and multispectral fluorescence lifetime catheter system. Sci Rep 2017; 7:8960. [PMID: 28827758 PMCID: PMC5566546 DOI: 10.1038/s41598-017-08056-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Accepted: 07/03/2017] [Indexed: 11/09/2022] Open
Abstract
Existing clinical intravascular imaging modalities are not capable of accurate detection of critical plaque pathophysiology in the coronary arteries. This study reports the first intravascular catheter combining intravascular ultrasound (IVUS) with multispectral fluorescence lifetime imaging (FLIm) that enables label-free simultaneous assessment of morphological and biochemical features of coronary vessels in vivo. A 3.7 Fr catheter with a fiber-optic channel was constructed based on a 40 MHz clinical IVUS catheter. The ability to safely acquire co-registered FLIm-IVUS data in vivo using Dextran40 solution flushing was demonstrated in swine coronary arteries. FLIm parameters from the arterial wall were consistent with the emission of fluorophores present in healthy arterial wall (collagen, elastin). Additionally, structural and biochemical features from atherosclerotic lesions were acquired in ex vivo human coronary samples and corroborated with histological findings. Current results show that FLIm parameters linked to the amount of structural proteins (e.g. collagen, elastin) and lipids (e.g. foam cells, extracellular lipids) in the first 200 μm of the intima provide important biochemical information that can supplement IVUS data for a comprehensive assessment of plaques pathophysiology. The unique FLIm-IVUS system evaluated here has the potential to provide a comprehensive insight into atherosclerotic lesion formation, diagnostics and response to therapy.
Collapse
Affiliation(s)
- Julien Bec
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA
| | - Jennifer E Phipps
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA
| | - Dimitris Gorpas
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA.,Institute of Biological and Medical Imaging, Helmholtz Zentrum, München, Germany
| | - Dinglong Ma
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA
| | - Hussain Fatakdawala
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA.,Abbott, Sylmar, CA, USA
| | - Kenneth B Margulies
- Cardiovascular Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, 19104, PA, USA
| | - Jeffrey A Southard
- UC Davis Health System, Division of Cardiovascular Medicine, University of California Davis, Sacramento, 95817, CA, USA
| | - Laura Marcu
- Department of Biomedical Engineering, University of California Davis, Davis, 95616, CA, USA.
| |
Collapse
|
27
|
Gorpas D, Koch M, Anastasopoulou M, Klemm U, Ntziachristos V. Benchmarking of fluorescence cameras through the use of a composite phantom. J Biomed Opt 2017; 22:16009. [PMID: 28301638 DOI: 10.1117/1.jbo.22.1.016009] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Accepted: 12/23/2016] [Indexed: 05/03/2023]
Abstract
Fluorescence molecular imaging (FMI) has shown potential to detect and delineate cancer during surgery or diagnostic endoscopy. Recent progress on imaging systems has allowed sensitive detection of fluorescent agents even in video rate mode. However, lack of standardization in fluorescence imaging challenges the clinical application of FMI, since the use of different systems may lead to different results from a given study, even when using the same fluorescent agent. In this work, we investigate the use of a composite fluorescence phantom, employed as an FMI standard, to offer a comprehensive method for validation and standardization of the performance of different imaging systems. To exclude user interaction, all phantom features are automatically extracted from the acquired epi-illumination color and fluorescence images, using appropriately constructed templates. These features are then employed to characterize the performance and compare different cameras to each other. The proposed method could serve as a framework toward the calibration and benchmarking of FMI systems, to facilitate their clinical translation.
Collapse
Affiliation(s)
- Dimitris Gorpas
- Technical University Munich, Chair for Biological Imaging, Arcisstrasse 21, Munich D-80333, GermanybHelmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstrasse 1, Neuherberg D-85764, Germany
| | - Maximilian Koch
- Technical University Munich, Chair for Biological Imaging, Arcisstrasse 21, Munich D-80333, GermanybHelmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstrasse 1, Neuherberg D-85764, Germany
| | - Maria Anastasopoulou
- Technical University Munich, Chair for Biological Imaging, Arcisstrasse 21, Munich D-80333, GermanybHelmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstrasse 1, Neuherberg D-85764, Germany
| | - Uwe Klemm
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstrasse 1, Neuherberg D-85764, Germany
| | - Vasilis Ntziachristos
- Technical University Munich, Chair for Biological Imaging, Arcisstrasse 21, Munich D-80333, GermanybHelmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstrasse 1, Neuherberg D-85764, Germany
| |
Collapse
|
28
|
Anastasopoulou M, Koch M, Gorpas D, Karlas A, Klemm U, Garcia-Allende PB, Ntziachristos V. Comprehensive phantom for interventional fluorescence molecular imaging. J Biomed Opt 2016; 21:091309. [PMID: 27304578 DOI: 10.1117/1.jbo.21.9.091309] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2016] [Accepted: 05/23/2016] [Indexed: 05/03/2023]
Abstract
Fluorescence imaging has been considered for over a half-century as a modality that could assist surgical guidance and visualization. The administration of fluorescent molecules with sensitivity to disease biomarkers and their imaging using a fluorescence camera can outline pathophysiological parameters of tissue invisible to the human eye during operation. The advent of fluorescent agents that target specific cellular responses and molecular pathways of disease has facilitated the intraoperative identification of cancer with improved sensitivity and specificity over nonspecific fluorescent dyes that only outline the vascular system and enhanced permeability effects. With these new abilities come unique requirements for developing phantoms to calibrate imaging systems and algorithms. We briefly review herein progress with fluorescence phantoms employed to validate fluorescence imaging systems and results. We identify current limitations and discuss the level of phantom complexity that may be required for developing a universal strategy for fluorescence imaging calibration. Finally, we present a phantom design that could be used as a tool for interlaboratory system performance evaluation.
Collapse
Affiliation(s)
- Maria Anastasopoulou
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| | - Maximilian Koch
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| | - Dimitris Gorpas
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| | - Angelos Karlas
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| | - Uwe Klemm
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 Germany
| | - Pilar Beatriz Garcia-Allende
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| | - Vasilis Ntziachristos
- Helmholtz Zentrum München, Institute for Biological and Medical Imaging, Ingolstädter Landstraße 1, Neuherberg D-85764 GermanybTechnical University Munich, Chair for Biological Imaging, Arcisstraße 21, Munich D-80333, Germany
| |
Collapse
|
29
|
Gorpas D, Ma D, Bec J, Yankelevich DR, Marcu L. Real-Time Visualization of Tissue Surface Biochemical Features Derived From Fluorescence Lifetime Measurements. IEEE Trans Med Imaging 2016; 35:1802-11. [PMID: 26890641 PMCID: PMC5131727 DOI: 10.1109/tmi.2016.2530621] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Fiber based fluorescence lifetime imaging has shown great potential for intraoperative diagnosis and guidance of surgical procedures. Here we describe a novel method addressing a significant challenge for the practical implementation of this technique, i.e., the real-time display of the quantified biochemical or functional tissue properties superimposed on the interrogated area. Specifically, an aiming beam (450 nm) generated by a continuous-wave laser beam was merged with the pulsed fluorescence excitation light in a single delivery/collection fiber and then imaged and segmented using a color-based algorithm. We demonstrate that this approach enables continuous delineation of the interrogated location and dynamic augmentation of the acquired frames with the corresponding fluorescence decay parameters. The method was evaluated on a fluorescence phantom and fresh tissue samples. Current results demonstrate that 34 frames per second can be achieved for augmenting videos of 640 × 512 pixels resolution. Also we show that the spatial resolution of the fluorescence lifetime map depends on the tissue optical properties, the scanning speed, and the frame rate. The dice similarity coefficient between the fluorescence phantom and the reconstructed maps was estimated to be as high as 93%. The reported method could become a valuable tool for augmenting the surgeon's field of view with diagnostic information derived from the analysis of fluorescence lifetime data in real-time using handheld, automated, or endoscopic scanning systems. Current method provides also a means for maintaining the tissue light exposure within safety limits. This study provides a framework for using an aiming beam with other point spectroscopy applications.
Collapse
Affiliation(s)
- Dimitris Gorpas
- Department of Biomedical Engineering, University of California Davis, CA 95616 USA
| | - Dinglong Ma
- Department of Biomedical Engineering, University of California Davis, CA 95616 USA
| | - Julien Bec
- Department of Biomedical Engineering, University of California Davis, CA 95616 USA
| | - Diego R. Yankelevich
- Department of Biomedical Engineering and with the Department of Electrical and Computer Engineering, University of California Davis, CA 95616 USA
| | - Laura Marcu
- Department of Biomedical Engineering, University of California Davis, CA 95616 USA
| |
Collapse
|
30
|
Fatakdawala H, Gorpas D, Bishop JW, Bec J, Ma D, Southard JA, Margulies KB, Marcu L. Fluorescence Lifetime Imaging Combined with Conventional Intravascular Ultrasound for Enhanced Assessment of Atherosclerotic Plaques: an Ex Vivo Study in Human Coronary Arteries. J Cardiovasc Transl Res 2015; 8:253-63. [PMID: 25931307 PMCID: PMC4473095 DOI: 10.1007/s12265-015-9627-3] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Accepted: 04/15/2015] [Indexed: 11/16/2022]
Abstract
This study evaluates the ability of label-free fluorescence lifetime imaging (FLIm) to complement intravascular ultrasound (IVUS) for concurrent visualization of human coronary vessel composition, structure, and pathology. Co-registered FLIm and IVUS data from 16 coronary segments were correlated to eight distinct pathological features including thin-cap fibroatheroma (TCFA). The sensitivity, specificity, and positive predictive value for combined FLIm-IVUS (89, 99, 89 %) were better than FLIm (70, 98, 88 %) and IVUS (45, 94, 62 %) alone in distinguishing between pathologies. FLIm can assess compositional changes in luminal surface through variations in fluorescence lifetime values (<3.5 ns for lipid-rich areas; >4 ns for collagen-rich areas) enabling detection of macrophages in fibrous caps (sensitivity, 86 %) and distinguishing between relatively stable thick-cap fibroatheromas and rupture-prone TCFA (sensitivity, 80 %) amongst other features. Current results demonstrate the potential of FLIm-IVUS as a new intravascular method for improved evaluation of plaques that may subsequently aid in guiding coronary intervention.
Collapse
Affiliation(s)
- Hussain Fatakdawala
- Department of Biomedical Engineering, University of California Davis, 451 E. Health Sciences Drive, Davis, CA, 95616, USA
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Ma D, Bec J, Gorpas D, Yankelevich D, Marcu L. Technique for real-time tissue characterization based on scanning multispectral fluorescence lifetime spectroscopy (ms-TRFS). Biomed Opt Express 2015; 6:987-1002. [PMID: 25798320 PMCID: PMC4361450 DOI: 10.1364/boe.6.000987] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 02/19/2015] [Accepted: 02/20/2015] [Indexed: 05/20/2023]
Abstract
We report a novel technique for continuous acquisition, processing and display of fluorescence lifetimes enabling real-time tissue diagnosis through a single hand held or biopsy fiber-optic probe. A scanning multispectral time-resolved fluorescence spectroscopy (ms-TRFS) with self-adjustable photon detection range was developed to account for the dynamic changes of fluorescence intensity typically encountered in clinical application. A fast algorithm was implemented in the ms-TRFS software platform, providing up to 15 Hz continuous display of fluorescence lifetime values. Potential applications of this technique, including biopsy guidance, and surgical margins delineation were demonstrated in proof-of-concept experiments. Current results showed accurate display of fluorescence lifetimes values and discrimination of distinct fluorescence markers and tissue types in real-time (< 100 ms per data point).
Collapse
Affiliation(s)
- Dinglong Ma
- Department of Biomedical Engineering, University of California, Davis, 451 Health Science Dr., Davis, CA 95616
USA
| | - Julien Bec
- Department of Biomedical Engineering, University of California, Davis, 451 Health Science Dr., Davis, CA 95616
USA
| | - Dimitris Gorpas
- Department of Biomedical Engineering, University of California, Davis, 451 Health Science Dr., Davis, CA 95616
USA
| | - Diego Yankelevich
- Department of Biomedical Engineering, University of California, Davis, 451 Health Science Dr., Davis, CA 95616
USA
- Department of Electrical and Computer Engineering, University of California, Davis, One Shields Ave., Davis, CA 95616
USA
| | - Laura Marcu
- Department of Biomedical Engineering, University of California, Davis, 451 Health Science Dr., Davis, CA 95616
USA
| |
Collapse
|
32
|
Gorpas D, Fatakdawala H, Bec J, Ma D, Yankelevich DR, Qi J, Marcu L. Fluorescence lifetime imaging and intravascular ultrasound: co-registration study using ex vivo human coronaries. IEEE Trans Med Imaging 2015; 34:156-66. [PMID: 25163056 PMCID: PMC4428614 DOI: 10.1109/tmi.2014.2350491] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Fluorescence lifetime imaging (FLIM) has demonstrated potential for robust assessment of atherosclerotic plaques biochemical composition and for complementing conventional intravascular ultrasound (IVUS), which provides information on plaque morphology. The success of such a bi-modal imaging modality depends on accurate segmentation of the IVUS images and proper angular registration between these two modalities. This paper reports a novel IVUS segmentation methodology addressing this issue. The image preprocessing consisted of denoising, using the Wiener filter, followed by image smoothing, implemented through the application of the alternating sequential filter on the edge separability metric images. Extraction of the lumen/intima and media/adventitia boundaries was achieved by tracing the gray-scale peaks over the A-lines of the IVUS preprocessed images. Cubic spline interpolation, in both cross-sectional and longitudinal directions, ensured boundary smoothness and continuity. The detection of the guide-wire artifact in both modalities is used for angular registration. Intraluminal studies were conducted in 13 ex vivo segments of human coronaries. The IVUS segmentation accuracy was assessed against independent manual tracings, providing 91.82% sensitivity and 97.55% specificity. The proposed methodology makes the bi-modal FLIM and IVUS approach feasible for comprehensive intravascular diagnosis by providing co-registered biochemical and morphological information of atherosclerotic plaques.
Collapse
Affiliation(s)
- Dimitris Gorpas
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| | - Hussain Fatakdawala
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| | - Julien Bec
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| | - Dinglong Ma
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| | - Diego R. Yankelevich
- Department of Biomedical Engineering and the Department of Electrical and Computer Engineering, University of California, Davis, CA 95616 USA
| | - Jinyi Qi
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| | - Laura Marcu
- Department of Biomedical Engineering, University of California, Davis, CA 95616 USA
| |
Collapse
|
33
|
Ma D, Bec J, Yankelevich DR, Gorpas D, Fatakdawala H, Marcu L. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications. J Biomed Opt 2014; 19:066004. [PMID: 24898604 PMCID: PMC4045254 DOI: 10.1117/1.jbo.19.6.066004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 05/05/2014] [Accepted: 05/06/2014] [Indexed: 05/24/2023]
Abstract
We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures.
Collapse
Affiliation(s)
- Dinglong Ma
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
| | - Julien Bec
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
| | - Diego R. Yankelevich
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
- University of California, Department of Electrical Engineering, 3101 Kemper Hall, Davis, California 95616
| | - Dimitris Gorpas
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
| | - Hussain Fatakdawala
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
| | - Laura Marcu
- University of California, Department of Biomedical Engineering, 451 Health Sciences Drive, Davis, California 95616
| |
Collapse
|
34
|
Gorpas D, Andersson-Engels S. Evaluation of a radiative transfer equation and diffusion approximation hybrid forward solver for fluorescence molecular imaging. J Biomed Opt 2012. [PMID: 23208221 DOI: 10.1117/1.jbo.17.12.126010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The solution of the forward problem in fluorescence molecular imaging strongly influences the successful convergence of the fluorophore reconstruction. The most common approach to meeting this problem has been to apply the diffusion approximation. However, this model is a first-order angular approximation of the radiative transfer equation, and thus is subject to some well-known limitations. This manuscript proposes a methodology that confronts these limitations by applying the radiative transfer equation in spatial regions in which the diffusion approximation gives decreased accuracy. The explicit integro differential equations that formulate this model were solved by applying the Galerkin finite element approximation. The required spatial discretization of the investigated domain was implemented through the Delaunay triangulation, while the azimuthal discretization scheme was used for the angular space. This model has been evaluated on two simulation geometries and the results were compared with results from an independent Monte Carlo method and the radiative transfer equation by calculating the absolute values of the relative errors between these models. The results show that the proposed forward solver can approximate the radiative transfer equation and the Monte Carlo method with better than 95% accuracy, while the accuracy of the diffusion approximation is approximately 10% lower.
Collapse
Affiliation(s)
- Dimitris Gorpas
- Information Technologies Institute, Centre of Research and Technology-Hellas, P.O. Box 60361, GR-570 01, Thessaloniki, Greece.
| | | |
Collapse
|
35
|
Gorpas D, Yova D, Politopoulos K. A priori fluorophore distribution estimation in fluorescence imaging through application of a segmentation process and a data fitting technique. Comput Med Imaging Graph 2010; 34:435-45. [DOI: 10.1016/j.compmedimag.2009.12.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2009] [Revised: 11/25/2009] [Accepted: 12/09/2009] [Indexed: 11/27/2022]
|
36
|
Gorpas D, Politopoulos K, Yova D. A binocular machine vision system for three-dimensional surface measurement of small objects. Comput Med Imaging Graph 2007; 31:625-37. [PMID: 17881188 DOI: 10.1016/j.compmedimag.2007.07.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2006] [Revised: 07/11/2007] [Accepted: 07/16/2007] [Indexed: 10/22/2022]
Abstract
Rendering three-dimensional information of a scene from optical measurements is very important for a wide variety of applications. However, computer vision advancements have not yet achieved the accurate three-dimensional reconstruction of objects smaller than 1 cm diameter. This paper describes the development of a novel volumetric method for small objects, using a binocular machine vision system. The achieved precision is high, providing a standard deviation of 0.04 mm. The robustness, of the system, issues from the lab prototype imaging system with the crucial z-axis movement without the need of further calibration and the fully automated volumetric algorithms.
Collapse
Affiliation(s)
- Dimitris Gorpas
- National Technical University of Athens, School of Electrical and Computer Engineering, Laboratory of Biomedical Optics and Applied Biophysics, 9 Iroon Polutexneiou Street, Zografou Campus, 157 73 Zografou, Greece.
| | | | | |
Collapse
|