1
|
Brunt AM, Haviland JS, Wheatley DA, Sydenham MA, Bloomfield DJ, Chan C, Cleator S, Coles CE, Donovan E, Fleming H, Glynn D, Goodman A, Griffin S, Hopwood P, Kirby AM, Kirwan CC, Nabi Z, Patel J, Sawyer E, Somaiah N, Syndikus I, Venables K, Yarnold JR, Bliss JM. One versus three weeks hypofractionated whole breast radiotherapy for early breast cancer treatment: the FAST-Forward phase III RCT. Health Technol Assess 2023; 27:1-176. [PMID: 37991196 PMCID: PMC11017153 DOI: 10.3310/wwbf1044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023] Open
Abstract
Background FAST-Forward aimed to identify a 5-fraction schedule of adjuvant radiotherapy delivered in 1 week that was non-inferior in terms of local cancer control and as safe as the standard 15-fraction regimen after primary surgery for early breast cancer. Published acute toxicity and 5-year results are presented here with other aspects of the trial. Design Multicentre phase III non-inferiority trial. Patients with invasive carcinoma of the breast (pT1-3pN0-1M0) after breast conservation surgery or mastectomy randomised (1 : 1 : 1) to 40 Gy in 15 fractions (3 weeks), 27 Gy or 26 Gy in 5 fractions (1 week) whole breast/chest wall (Main Trial). Primary endpoint was ipsilateral breast tumour relapse; assuming 2% 5-year incidence for 40 Gy, non-inferiority pre-defined as < 1.6% excess for 5-fraction schedules (critical hazard ratio = 1.81). Normal tissue effects were assessed independently by clinicians, patients and photographs. Sub-studies Two acute skin toxicity sub-studies were undertaken to confirm safety of the test schedules. Primary endpoint was proportion of patients with grade ≥ 3 acute breast skin toxicity at any time from the start of radiotherapy to 4 weeks after completion. Nodal Sub-Study patients had breast/chest wall plus axillary radiotherapy testing the same three schedules, reduced to the 40 and 26 Gy groups on amendment, with the primary endpoint of 5-year patient-reported arm/hand swelling. Limitations A sequential hypofractionated or simultaneous integrated boost has not been studied. Participants Ninety-seven UK centres recruited 4096 patients (1361:40 Gy, 1367:27 Gy, 1368:26 Gy) into the Main Trial from November 2011 to June 2014. The Nodal Sub-Study recruited an additional 469 patients from 50 UK centres. One hundred and ninety and 162 Main Trial patients were included in the acute toxicity sub-studies. Results Acute toxicity sub-studies evaluable patients: (1) acute grade 3 Radiation Therapy Oncology Group toxicity reported in 40 Gy/15 fractions 6/44 (13.6%); 27 Gy/5 fractions 5/51 (9.8%); 26 Gy/5 fractions 3/52 (5.8%). (2) Grade 3 common toxicity criteria for adverse effects toxicity reported for one patient. At 71-month median follow-up in the Main Trial, 79 ipsilateral breast tumour relapse events (40 Gy: 31, 27 Gy: 27, 26 Gy: 21); hazard ratios (95% confidence interval) versus 40 Gy were 27 Gy: 0.86 (0.51 to 1.44), 26 Gy: 0.67 (0.38 to 1.16). With 2.1% (1.4 to 3.1) 5-year incidence ipsilateral breast tumour relapse after 40 Gy, estimated absolute differences versus 40 Gy (non-inferiority test) were -0.3% (-1.0-0.9) for 27 Gy (p = 0.0022) and -0.7% (-1.3-0.3) for 26 Gy (p = 0.00019). Five-year prevalence of any clinician-assessed moderate/marked breast normal tissue effects was 40 Gy: 98/986 (9.9%), 27 Gy: 155/1005 (15.4%), 26 Gy: 121/1020 (11.9%). Across all clinician assessments from 1 to 5 years, odds ratios versus 40 Gy were 1.55 (1.32 to 1.83; p < 0.0001) for 27 Gy and 1.12 (0.94-1.34; p = 0.20) for 26 Gy. Patient and photographic assessments showed higher normal tissue effects risk for 27 Gy versus 40 Gy but not for 26 Gy. Nodal Sub-Study reported no arm/hand swelling in 80% and 77% in 40 Gy and 26 Gy at baseline, and 73% and 76% at 24 months. The prevalence of moderate/marked arm/hand swelling at 24 months was 10% versus 7% for 40 Gy compared with 26 Gy. Interpretation Five-year local tumour incidence and normal tissue effects prevalence show 26 Gy in 5 fractions in 1 week is a safe and effective alternative to 40 Gy in 15 fractions for patients prescribed adjuvant local radiotherapy after primary surgery for early-stage breast cancer. Future work Ten-year Main Trial follow-up is essential. Inclusion in hypofractionation meta-analysis ongoing. A future hypofractionated boost trial is strongly supported. Trial registration FAST-Forward was sponsored by The Institute of Cancer Research and was registered as ISRCTN19906132. Funding This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 09/01/47) and is published in full in Health Technology Assessment; Vol. 27, No. 25. See the NIHR Funding and Awards website for further award information.
Collapse
|
2
|
De-Colle C, Kirby A, Russell N, Shaitelman S, Currey A, Donovan E, Hahn E, Han K, Anandadas C, Mahmood F, Lorenzen E, van den Bongard D, Groot Koerkamp M, Houweling A, Nachbar M, Thorwarth D, Zips D. Adaptive radiotherapy for breast cancer. Clin Transl Radiat Oncol 2023; 39:100564. [PMID: 36632056 PMCID: PMC9826896 DOI: 10.1016/j.ctro.2022.100564] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 12/07/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
Research in the field of local and locoregional breast cancer radiotherapy aims to maintain excellent oncological outcomes while reducing treatment-related toxicity. Adaptive radiotherapy (ART) considers variations in target and organs at risk (OARs) anatomy occurring during the treatment course and integrates these in re-optimized treatment plans. Exploiting ART routinely in clinic may result in smaller target volumes and better OAR sparing, which may lead to reduction of acute as well as late toxicities. In this review MR-guided and CT-guided ART for breast cancer patients according to different clinical scenarios (neoadjuvant and adjuvant partial breast irradiation, whole breast, chest wall and regional nodal irradiation) are reviewed and their advantages as well as challenging aspects discussed.
Collapse
|
3
|
Rishi A, Albuquerque K, Donovan E, Jhingran A, Beriwal S, Glaser S, Fernandez D, Ahmed K, Montejo M. Definitive High-Dose Radiotherapy for Primary Vulvar Cancer: The DRIVE Multicenter Cohort Study. Int J Radiat Oncol Biol Phys 2022. [DOI: 10.1016/j.ijrobp.2022.07.597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
4
|
Rowbottom B, Galhardo A, Donovan E, Gameiro S. Feasibility randomized controlled trial of a self-guided online intervention to promote psychosocial adjustment to unmet parenthood goals. Hum Reprod 2022; 37:2412-2425. [PMID: 36001052 PMCID: PMC9527459 DOI: 10.1093/humrep/deac168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 06/30/2022] [Indexed: 12/03/2022] Open
Abstract
STUDY QUESTION Is it feasible to implement and evaluate an online self-guided psychosocial intervention for people with an unmet parenthood goal (UPG), aimed to improve well-being, in an online randomized controlled trial (RCT)? SUMMARY ANSWER The evaluation of an online bilingual self-guided psychosocial intervention for people with a UPG is feasible, reflected by high demand, good acceptability, good adaptation and promise of efficacy, but minor adjustments to the intervention and study design of the RCT should be made to enhance practicality. WHAT IS KNOWN ALREADY Self-identifying as having a UPG, defined as being unable to have children or as many as desired, is associated with impaired well-being and mental health. Practice guidelines and regulatory bodies have highlighted the need to address the lack of evidence-based support for this population. It is unknown if MyJourney (www.myjourney.pt), the first online self-guided intervention for people with UPGs, can be implemented and evaluated in an RCT. STUDY DESIGN, SIZE, DURATION To evaluate the feasibility of MyJourney, we conducted a registered, two-arm, parallel group, non-blinded feasibility RCT, with a 1:1 computer-generated randomized allocation and embedded qualitative process evaluation. Participants were included between November 2020 and March 2021. Assessments were made before randomization (T1), 10 weeks (T2) and 6 months after (T3, intervention group only). Participants allocated to the intervention group received an email to access MyJourney immediately after randomization. Participants in the waitlist control group were given access to MyJourney after completing the 10-week assessment (T2). PARTICIPANTS/MATERIALS, SETTING, METHODS Participants were recruited via social media advertising of MyJourney and its feasibility study. People who self-identified as having a UPG could click on a link to participate, and of these 235 were randomized. Outcome measures related to demand, acceptability, implementation, practicality, adaptation and limited efficacy were assessed via online surveys. The primary outcome in limited efficacy testing was hedonic well-being, measured with the World Health Organisation Wellbeing Index (WHO-5). MAIN RESULTS AND THE ROLE OF CHANCE Participation and retention rates were 58.3%, 31.7% (T2) and 45.2% (T3, intervention group only), respectively. Of participants invited to register with MyJourney, 91 (76.5%) set up an account, 51 (47.2%) completed the first Step of MyJourney, 12 (11.1%) completed six Steps (sufficient dose) and 6 (5.6%) completed all Steps within the 10-week recommended period. Acceptability ranged from 2.79 (successful at supporting) to 4.42 (easy to understand) on a 1 (not at all) to 5 (extremely acceptable) scale. Average time to complete sufficient dose was 15.6 h (SD = 18.15) and to complete all Steps was 12.4 h (SD = 18.15), with no differences found for participants using MyJourney in Portuguese and English. Modified intention-to-treat analysis showed a moderate increase in well-being from T1 to T2 in the intervention group (ηp2 = 0.156, mean difference (MD) = 9.300 (2.285, 16.315)) and no changes in the control group (ηp2 = 0.000, MD = 0.047 (−3.265, 3.358)). Participants in the process evaluation reported MyJourney was needed and answered their needs for support (reflecting high demand and acceptability), the recommended period to engage with MyJourney was short, and their engagement was influenced by multiple factors, including personal (e.g. lack of time) and MyJourney related (e.g. reminders). LIMITATIONS, REASONS FOR CAUTION Participants were mostly white, well-educated, employed, childless women. Non-blinded allocation, use of self-reported questionnaire assessments and high attrition in the intervention group could have triggered bias favourable to positive evaluations of MyJourney and resulted in low power to detect T2 to T3 changes in limited efficacy outcomes. WIDER IMPLICATIONS OF THE FINDINGS MyJourney can proceed to efficacy testing, but future work should eliminate barriers for engagement and explore strategies to maximize adherence. Entities wanting to support people with UPGs now have a freely accessible and promising resource that can be further tested and evaluated in different settings. STUDY FUNDING/COMPETING INTEREST(S) MyJourney’s development was funded by the charity Portuguese Fertility Association, Cardiff University and University of Coimbra (CINEICC). Dr S.G. reports consultancy fees from Ferring Pharmaceuticals A/S, speaker fees from Access Fertility, SONA-Pharm LLC, Meridiano Congress International and Gedeon Richter and grants from Merck Serono Ltd. Bethan Rowbottom holds a PhD scholarship funded by the School of Psychology, Cardiff University. The other authors have no conflicts of interest. TRIAL REGISTRATION NUMBER Clinical Trials.gov NCT04850482.
Collapse
|
5
|
Wheatley D, Haviland J, Patel J, Sydenham M, Alhasso A, Chan C, Cleator S, Coles C, Donovan E, Kirby A, Kirwan C, Nabi Z, Sawyer E, Somaiah N, Syndikus I, Venables K, Yarnold J, Brunt A, Bliss J. OC-0101 First results of FAST-Forward phase 3 RCT nodal substudy: 3-year normal tissue effects. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)02477-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
6
|
Donovan E, Albuquerque K, Mantz C, Beriwal S, Keller A, Chen H, Lo S, Leung E. The Role of Stereotactic Body Radiotherapy (SBRT) in Oligometastatic and Oligoprogressive Gynecologic Malignancies: A Multi-Institutional Pooled Analysis. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
7
|
Leung E, Gladwish A, Davidson M, Taggar A, Barnes E, Donovan E, Gien L, Covens A, Vicus D, Kupets R, Han K, Velker V, Mendez L, MacKay H, Cheung P, Loblaw D, D'Souza D. Stereotactic Pelvic Adjuvant Radiation Therapy in Cancers of the Uterus (SPARTACUS): A Multicenter Prospective Trial Evaluating Acute Toxicities and Patient Reported Outcomes. Int J Radiat Oncol Biol Phys 2021. [DOI: 10.1016/j.ijrobp.2021.07.072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Cozma AI, Martell K, Ravi A, Barnes E, Donovan E, Paudel M, Leung E, Taggar A. Relationship of Urethral Dose and Genitourinary Toxicity Among Patients Receiving Vaginal High Dose Rate Interstitial Brachytherapy. Clin Oncol (R Coll Radiol) 2021; 33:773-779. [PMID: 34092463 DOI: 10.1016/j.clon.2021.05.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Revised: 03/11/2021] [Accepted: 05/17/2021] [Indexed: 11/16/2022]
Abstract
AIMS Interstitial brachytherapy (ISBT) plays an important role in the management of locally advanced gynaecological malignancies. However, the relationship between urinary toxicity and dose to the urethra is not well understood. We sought to evaluate the correlation between urethral dose and the incidence of genitourinary complications among patients undergoing vaginal high dose rate ISBT. MATERIALS AND METHODS Eighty-three patients treated with ISBT between August 2014 and April 2018 were retrospectively reviewed. CTCAE version 5.0 was used to grade toxicity. Individual treatment plans were evaluated to collect dose parameters. Urethral contours were added to the structure sets using a uniform 1 cm diameter brush and minimum doses to the hottest 0.1, 0.2 and 0.5 cm3 (D0.1cm3, D0.2cm3 and D0.5cm3) of the urethra were obtained. Total (ISBT ± external beam radiotherapy) equivalent doses in 2 Gy fractions (EQD2) received by the targets and organs at risk were calculated. Numerical counts (%) and medians (interquartile range) were used to characterise the data. Fisher's exact and the Mann-Whitney-Wilcox tests were used as appropriate. Receiver operator curve analysis was used to define the urethral threshold dose that correlated to genitourinary toxicity. RESULTS The median age and follow-up times were 67 years (59-75) and 25 months (16-37), respectively. Patients had predominantly primary endometrial (49%) and vaginal (37%) cancer, with four (5%) patients with metastatic rectal cancer to the vagina. Twenty-four of 79 (30%) patients experienced acute genitourinary toxicity and 34 of 71 (48%) experienced late genitourinary toxicity. In both analyses, the median urethral dose was significantly higher among those with toxicity. Receiver operator curve analysis indicated that D0.1cm3, D0.2cm3 and D0.5cm3 of the urethra were associated with the development of toxicity at doses >78, >71 and >62 Gy, respectively. CONCLUSION Urethral dose seems to predict genitourinary toxicity in ISBT of vaginal tumours. Further study with an expanded cohort and longer follow-up is warranted.
Collapse
|
9
|
Ranger A, Dunlop A, Grimwood A, Durie E, Donovan E, Havilland J, Harris E, McNair H, Kirby AM. Voluntary versus ABC breath-hold in the context of VMAT for breast and locoregional lymph node radiotherapy including the internal mammary chain. Clin Transl Radiat Oncol 2021; 27:164-168. [PMID: 33681483 PMCID: PMC7918266 DOI: 10.1016/j.ctro.2021.02.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 01/07/2021] [Accepted: 02/07/2021] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABC™, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus. METHOD Patients with breast cancer requiring pan regional lymph node VMAT +/- wax bolus in breath-hold were CT scanned in vDIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1-7 and the other for fractions 8-15. Daily cone beam computed tomography (CBCT) was performed and registered to planning-CT using bony anatomy. Within-patient comparisons of mean daily chest wall position were made using a paired t-test. Population, systematic (∑) and random errors (α) were estimated. Intrafraction reproducibility was assessed by comparing chest wall position and diaphragm movement between consecutive breath holds on CBCT. RESULTS 16 patients were recruited. All completed treatment with both techniques (9 patients with wax bolus, 7 patients without). CBCT derived ∑ were 2.1-6.4 mm (ABC_DIBH) and 2.1-4.9 mm (vDIBH), α were 1.7-2.6 mm (ABC_DIBH) and 2.2-2.7 mm (vDIBH) and mean daily chest wall displacements (MD) were 0.0-1.5 mm (ABC_DIBH) and -0.1-1.6 vDIBH (all p non-significant). Chest wall and diaphragm position was equivalent between consecutive breath holds in ABC and vDIBH (median difference 1.0 mm and 0.8 mm respectively, non p significant) demonstrating equivalent intrafraction reproducibility. CONCLUSION This study demonstrates that a simple voluntary breath hold technique is feasible in combination with VMAT (+/- bolus) and is as reproducible as ABC_DIBH with VMAT for the irradiation of the breast and axillary and IMC lymph nodes in breast cancer patients.
Collapse
|
10
|
Donovan E, Cheung P, Erler D, Davidson M, Sahgal A, Chung H, Poon I, Taggar A, Barnes E, Jerzak K, Gien L, Leung E. Stereotactic Ablative Radiotherapy (SABR) in Oligometastatic and Oligoprogressive Gynecologic Cancers: Clinical Outcomes of a Single Institution Analysis. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.1389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Donovan E, Pond G, Seow H, Ellis P, Swaminath A. Cardiac Morbidity Following Radical Thoracic Chemoradiotherapy for Locally Advanced Lung Cancer: A Population-Based Cohort Study. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.1243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Donovan E, Xie F, Chu W, Louie A, Kapoor A, Siva S, Swaminath A. Cost-Effectiveness of Radiofrequency Ablation (RFA) Versus Stereotactic Body Radiotherapy (SBRT) in the Treatment of Localized Renal Cell Carcinoma. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.2430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
13
|
Safavi A, Elzibak A, Donovan E, Detsky J, Louie A. Radiotherapy in Patients With Cardiovascular Implantable Electronic Devices: A Survey of Multi-Disciplinary Radiation Oncology Professionals. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
14
|
Leung E, D'Alimonte L, Taggar A, Barnes E, Donovan E, Barbera L, Ravi A. Integrated Intraoperative MRI-Guided Brachytherapy for Cervical Cancer: An Institutional Experience of Treatment Workflow, Planning and Patient Toxicities. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.1538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
Brunt AM, Haviland JS, Sydenham M, Agrawal RK, Algurafi H, Alhasso A, Barrett-Lee P, Bliss P, Bloomfield D, Bowen J, Donovan E, Goodman A, Harnett A, Hogg M, Kumar S, Passant H, Quigley M, Sherwin L, Stewart A, Syndikus I, Tremlett J, Tsang Y, Venables K, Wheatley D, Bliss JM, Yarnold JR. Ten-Year Results of FAST: A Randomized Controlled Trial of 5-Fraction Whole-Breast Radiotherapy for Early Breast Cancer. J Clin Oncol 2020; 38:3261-3272. [PMID: 32663119 PMCID: PMC7526720 DOI: 10.1200/jco.19.02750] [Citation(s) in RCA: 150] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/19/2020] [Indexed: 11/30/2022] Open
Abstract
PURPOSE Previous studies of hypofractionated adjuvant whole-breast radiotherapy for early breast cancer established a 15- or 16-fraction (fr) regimen as standard. The FAST Trial (CRUKE/04/015) evaluated normal tissue effects (NTE) and disease outcomes after 5-fr regimens. Ten-year results are presented. METHODS Women ≥ 50 years of age with low-risk invasive breast carcinoma (pT1-2 pN0) were randomly assigned to 50 Gy/25 fr (5 weeks) or 30 or 28.5 Gy in 5 once-weekly fr of 6.0 or 5.7 Gy. The primary end point was change in photographic breast appearance at 2 and 5 years; secondary end points were physician assessments of NTE and local tumor control. Odds ratios (ORs) from longitudinal analyses compared regimens. RESULTS A total of 915 women were recruited from 18 UK centers (2004-2007). Five-year photographs were available for 615/862 (71%) eligible patients. ORs for change in photographic breast appearance were 1.64 (95% CI, 1.08 to 2.49; P = .019) for 30 Gy and 1.10 (95% CI, 0.70 to 1.71; P = .686) for 28.5 Gy versus 50 Gy. α/β estimate for photographic end point was 2.7 Gy (95% CI, 1.5 to 3.9 Gy), giving a 5-fr schedule of 28 Gy (95% CI, 26 to 30 Gy) estimated to be isoeffective with 50 Gy/25 fr. ORs for any moderate/marked physician-assessed breast NTE (shrinkage, induration, telangiectasia, edema) were 2.12 (95% CI, 1.55 to 2.89; P < .001) for 30 Gy and 1.22 (95% CI, 0.87 to 1.72; P = .248) for 28.5 Gy versus 50 Gy. With 9.9 years median follow-up, 11 ipsilateral breast cancer events (50 Gy: 3; 30 Gy: 4; 28.5 Gy: 4) and 96 deaths (50 Gy: 30; 30 Gy: 33; 28.5 Gy: 33) have occurred. CONCLUSION At 10 years, there was no significant difference in NTE rates after 28.5 Gy/5 fr compared with 50 Gy/25 fr, but NTE were higher after 30 Gy/5 fr. Results confirm the published 3-year findings that a once-weekly 5-fr schedule of whole-breast radiotherapy can be identified that appears to be radiobiologically comparable for NTE to a conventionally fractionated regimen.
Collapse
|
16
|
Voruganti IS, Donovan E, Walker-Dilks C, Swaminath A. Chest wall toxicity after stereotactic radiation in early lung cancer: a systematic review. Curr Oncol 2020; 27:179-189. [PMID: 32905234 PMCID: PMC7467794 DOI: 10.3747/co.27.5959] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Background Radiation-induced chest wall pain (cwp) and rib fracture (rf) are late adverse effects after stereotactic body radiation therapy (sbrt) for stage i non-small-cell lung cancer (nsclc); however, the literature about their incidence and risk factors shows variability. We performed a systematic review to determine the pooled incidence of cwp and rf in the relevant population. Methods A literature search using the prisma (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines considered English publications in medline and embase from January 1996 to August 2017. Abstracts were screened, followed by full-text review and data extraction. Results The database searches identified 547 records. Twenty-eight publications comprising 3892 patients met the inclusion criteria. Median reported ages and follow-up durations fell into the ranges 67-82 years and 12-84 months. Prescriptions fell into the range of 40-70 Gy in 3-10 fractions. Despite study heterogeneity, the pooled incidences of cwp and rf were estimated to be 8.94% and 5.27% respectively. Nineteen studies reported cwp grade: 58 of 308 patients (18.8%) experienced grades 3-4 cwp (no grade 5 events reported). Thirteen studies reported rf grade: grades 3-4 rf were observed in 9 of 113 patients (7.96%). A high chest wall V30 was an important predictor of cwp and rf. Conclusions In patients with stage i nsclc, rates of cwp and rf after sbrt are low; however, tumour location, accurate toxicity reporting, and dose-fractionation schemes might alter those rates. Prospective correlation with dosimetry and quality of life assessment will further improve the understanding of cwp and rf after sbrt.
Collapse
|
17
|
Dautovich ND, Dzierzewski J, Sabet S, Soto P, Donovan E, Kleva C. 0313 Is Healthy Sleep Possible for Professional Firefighters? A Comparison of “On-Duty” and “Off-Duty” Sleep Quantity and Quality. Sleep 2020. [DOI: 10.1093/sleep/zsaa056.310] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Healthy sleep is vital for firefighter safety, health, wellness, and for public well-being. However, professional firefighters experience disturbed sleep at disproportionately high rates. The current study investigated whether firefighters can obtain healthy sleep by identifying (1) differences in sleep while “on-duty” and “off-duty” and (2) risk factors for poor sleep.
Methods
Professional firefighters in Richmond, Virginia’s Department of Fire and Emergency Services (N=268), reported their sleep using the Pittsburgh Sleep Quality Index (PSQI) both on- and off-duty. Good and poor sleepers were identified using the PSQI global score cutoff of 5. Demographic and STOP-BANG questionnaires were also completed.
Results
Using a repeated measures MANOVA, on-duty sleep was significantly worse compared to off-duty sleep across PSQI component and global scores F(7, 253)=45.24 p<.001, η²=.56. On-duty, 76.1% of firefighters were classified as poor sleepers compared to 42.9% off-duty. 34.7% were reclassified as good sleepers or stayed good sleepers (22.4%) when off-duty. A sizeable minority experienced consistently poor sleep while on- and off-duty (41.4%), and a small number reported worse sleep when off-duty (1.5%). More night calls and poorer self-rated mental health predicted worse on-duty sleep (p<.001) and poorer self-rated mental health predicted worse off-duty sleep (p<.001).
Conclusion
Healthy sleep is possible for professional firefighters. Almost a quarter of the sample was classified as “good sleepers” on-duty and over half were classified as “good sleepers” off-duty. Nonetheless, sleep on-duty was significantly worse overall, with over a third of the sample experiencing consistently poor sleep. When working a 24-hour variable shift schedule, it appears that poor sleep may “carryover” from on-duty to off-duty. Poorer self-rated mental health and more night calls were identified as risk factors. Further research is needed to probe risk and protective factors within this population.
Support
N/A
Collapse
|
18
|
Peng J, Donovan E, Ellis P, Pond G, Swaminath A. A Comparison of Radiation Techniques in Patients Treated with Concurrent Chemoradiation for Stage III Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys 2019. [DOI: 10.1016/j.ijrobp.2019.06.2427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
19
|
Ranger A, Dunlop A, Donovan E, Harris E, DeSouza N, McNair H, Kirby A. EP-1323 HeartSpare Plus: A comparison of the feasibility and acute toxicity of internal mammary chain RT. Radiother Oncol 2019. [DOI: 10.1016/s0167-8140(19)31743-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
20
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
21
|
Angelopoulos V, Cruce P, Drozdov A, Grimes EW, Hatzigeorgiu N, King DA, Larson D, Lewis JW, McTiernan JM, Roberts DA, Russell CL, Hori T, Kasahara Y, Kumamoto A, Matsuoka A, Miyashita Y, Miyoshi Y, Shinohara I, Teramoto M, Faden JB, Halford AJ, McCarthy M, Millan RM, Sample JG, Smith DM, Woodger LA, Masson A, Narock AA, Asamura K, Chang TF, Chiang CY, Kazama Y, Keika K, Matsuda S, Segawa T, Seki K, Shoji M, Tam SWY, Umemura N, Wang BJ, Wang SY, Redmon R, Rodriguez JV, Singer HJ, Vandegriff J, Abe S, Nose M, Shinbori A, Tanaka YM, UeNo S, Andersson L, Dunn P, Fowler C, Halekas JS, Hara T, Harada Y, Lee CO, Lillis R, Mitchell DL, Argall MR, Bromund K, Burch JL, Cohen IJ, Galloy M, Giles B, Jaynes AN, Le Contel O, Oka M, Phan TD, Walsh BM, Westlake J, Wilder FD, Bale SD, Livi R, Pulupa M, Whittlesey P, DeWolfe A, Harter B, Lucas E, Auster U, Bonnell JW, Cully CM, Donovan E, Ergun RE, Frey HU, Jackel B, Keiling A, Korth H, McFadden JP, Nishimura Y, Plaschke F, Robert P, Turner DL, Weygand JM, Candey RM, Johnson RC, Kovalick T, Liu MH, McGuire RE, Breneman A, Kersten K, Schroeder P. The Space Physics Environment Data Analysis System (SPEDAS). SPACE SCIENCE REVIEWS 2019; 215:9. [PMID: 30880847 PMCID: PMC6380193 DOI: 10.1007/s11214-018-0576-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 12/29/2018] [Indexed: 05/31/2023]
Abstract
With the advent of the Heliophysics/Geospace System Observatory (H/GSO), a complement of multi-spacecraft missions and ground-based observatories to study the space environment, data retrieval, analysis, and visualization of space physics data can be daunting. The Space Physics Environment Data Analysis System (SPEDAS), a grass-roots software development platform (www.spedas.org), is now officially supported by NASA Heliophysics as part of its data environment infrastructure. It serves more than a dozen space missions and ground observatories and can integrate the full complement of past and upcoming space physics missions with minimal resources, following clear, simple, and well-proven guidelines. Free, modular and configurable to the needs of individual missions, it works in both command-line (ideal for experienced users) and Graphical User Interface (GUI) mode (reducing the learning curve for first-time users). Both options have "crib-sheets," user-command sequences in ASCII format that can facilitate record-and-repeat actions, especially for complex operations and plotting. Crib-sheets enhance scientific interactions, as users can move rapidly and accurately from exchanges of technical information on data processing to efficient discussions regarding data interpretation and science. SPEDAS can readily query and ingest all International Solar Terrestrial Physics (ISTP)-compatible products from the Space Physics Data Facility (SPDF), enabling access to a vast collection of historic and current mission data. The planned incorporation of Heliophysics Application Programmer's Interface (HAPI) standards will facilitate data ingestion from distributed datasets that adhere to these standards. Although SPEDAS is currently Interactive Data Language (IDL)-based (and interfaces to Java-based tools such as Autoplot), efforts are under-way to expand it further to work with python (first as an interface tool and potentially even receiving an under-the-hood replacement). We review the SPEDAS development history, goals, and current implementation. We explain its "modes of use" with examples geared for users and outline its technical implementation and requirements with software developers in mind. We also describe SPEDAS personnel and software management, interfaces with other organizations, resources and support structure available to the community, and future development plans. ELECTRONIC SUPPLEMENTARY MATERIAL The online version of this article (10.1007/s11214-018-0576-4) contains supplementary material, which is available to authorized users.
Collapse
|
22
|
Ranger A, Dunlop A, Shah P, Amin K, Henderson D, Bartlett FR, Knowles C, Brigden B, Lacey C, Donovan E, Harris E, Kirby AM. Evaluation of a Novel Field-placement Algorithm for Locoregional Breast Cancer Radiotherapy Including the Internal Mammary Chain. Clin Oncol (R Coll Radiol) 2019; 31:25-33. [PMID: 30078523 DOI: 10.1016/j.clon.2018.06.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Revised: 06/18/2018] [Accepted: 06/25/2018] [Indexed: 10/28/2022]
Abstract
AIMS Irradiation of the internal mammary chain (IMC) is increasing following recently published data, but the need for formal delineation of lymph node volumes is slowing implementation in some healthcare settings. A field-placement algorithm for irradiating locoregional lymph nodes including the IMC could reduce the resource impact of introducing irradiation of the IMC. This study describes the development and evaluation of such an algorithm. MATERIALS AND METHODS An algorithm was developed in which six points representing lymph node clinical target volume borders (based on European Society for Radiotherapy and Oncology consensus nodal contouring guidelines) were placed on computed tomography-defined anatomical landmarks and used to place tangential and nodal fields. Single-centre testing in 20 cases assessed the success of the algorithm in covering planning target volumes (PTVs) and adequately sparing organs at risk. Plans derived using the points algorithm were also compared with plans generated following formal delineation of nodal PTVs, using the Wilcoxon signed rank test. Timing data for point placement were collected. Multicentre testing using the same methods was then carried out to establish whether the technique was transferable to other centres. RESULTS Single-centre testing showed that 95% of cases met the nodal PTV coverage dose constraints (binomial probability confidence interval 75.1-99.9%) with no statistically significant reduction in mean heart dose or ipsilateral lung V17Gy associated with formal nodal delineation. In multicentre testing, 69% of cases met nodal PTV dose constraints and there was a statistically significant difference in IMC PTV coverage using the points algorithm when compared with formally delineated nodal volumes (P < 0.01). However, there was no difference in axillary level 1-4 PTV coverage (P = 0.11) with all cases meeting target volume constraints. CONCLUSIONS The optimal strategy for breast and locoregional lymph node radiotherapy is target volume delineation. However, use of this novel points-based field-placement algorithm results in dosimetrically acceptable plans without the need for formal lymph node contouring in a single-centre setting and for the breast and level 1-4 axilla in a multicentre setting. Further quality assurance measures are needed to enable implementation of the algorithm for irradiation of the IMC in a multicentre setting.
Collapse
|
23
|
Moquet J, Higueras M, Donovan E, Boyle S, Barnard S, Bricknell C, Sun M, Gothard L, O’Brien G, Cruz-Garcia L, Badie C, Ainsbury E, Somaiah N. Dicentric Dose Estimates for Patients Undergoing Radiotherapy in the RTGene Study to Assess Blood Dosimetric Models and the New Bayesian Method for Gradient Exposure. Radiat Res 2018; 190:596-604. [PMID: 30234457 PMCID: PMC6426678 DOI: 10.1667/rr15116.1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The RTGene study was focused on the development and validation of new transcriptional biomarkers for prediction of individual radiotherapy patient responses to ionizing radiation. In parallel, for validation purposes, this study incorporated conventional biomarkers of radiation exposure, including the dicentric assay. Peripheral blood samples were taken with ethical approval and informed consent from a total of 20 patients undergoing external beam radiotherapy for breast, lung, gastrointestinal or genitourinary tumors. For the dicentric assay, two samples were taken from each patient: prior to radiotherapy and before the final fraction. Blood samples were set up using standard methods for the dicentric assay. All the baseline samples had dicentric frequencies consistent with the expected background for the normal population. For blood taken before the final fraction, all the samples displayed distributions of aberrations, which are indicative of partial-body exposures. Whole-body and partial-body cytogenetic doses were calculated with reference to a 250-kVp X-ray calibration curve and then compared to the dose to blood derived using two newly developed blood dosimetric models. Initial comparisons indicated that the relationship between these measures of dose appear very promising, with a correlation of 0.88 (P = 0.001). A new Bayesian zero-inflated Poisson finite mixture method was applied to the dicentric data, and partial-body dose estimates showed no significant difference (P > 0.999) from those calculated by the contaminated Poisson technique. The next step will be further development and validation in a larger patient group.
Collapse
|
24
|
Voruganti I, Donovan E, Walker C, Swaminath A. Systematic Review of the Incidence of Chest Wall Toxicity Following Stereotactic Body Radiation Therapy for Early Stage Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.07.1909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
25
|
Donovan E, Dhesy-Thind S, Swaminath A, Leong D, Voruganti S, Sussman J, Wright J, Okawara G, Dokainish H, Pond G, Fraser G, Kavsak P, Sagar S. Does Modern Mediastinal Irradiation Cause Acute Subclinical Cardiac Toxicity? The Final Results of the MEDICATE Study (Mediastinal Irradiation and Cardio-Toxic Effects). Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.06.231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
26
|
Shahi J, Peng J, Donovan E, Wong R, Tsakiridis T, Quan K, Swaminath A. Outcomes of Stereotactic Body Radiation Therapy for Abdominopelvic Oligometastases. Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.07.406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
27
|
Cruz-Garcia L, O’Brien G, Donovan E, Gothard L, Boyle S, Laval A, Testard I, Ponge L, Woźniak G, Miszczyk L, Candéias SM, Ainsbury E, Widlak P, Somaiah N, Badie C. Influence of Confounding Factors on Radiation Dose Estimation Using In Vivo Validated Transcriptional Biomarkers. HEALTH PHYSICS 2018; 115:90-101. [PMID: 29787434 PMCID: PMC5967635 DOI: 10.1097/hp.0000000000000844] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
For triage purposes following a nuclear accident, blood-based gene expression biomarkers can provide rapid dose estimates for a large number of individuals. Ionizing-radiation-responsive genes are regulated through the DNA damage-response pathway, which includes activation of multiple transcription factors. Modulators of this pathway could potentially affect the response of these biomarkers and consequently compromise accurate dose estimation calculations. In the present study, four potential confounding factors were selected: cancer condition, sex, simulated bacterial infection (lipopolysaccharide), and curcumin, an anti-inflammatory/antioxidant agent. Their potential influence on the transcriptional response to radiation of the genes CCNG1 and PHPT1, two biomarkers of radiation exposure ex vivo, was assessed. First, both CCNG1 and PHPT1 were detected in vivo in blood samples from radiotherapy patients and as such were validated as biomarkers of exposure. Importantly, their basal expression level was slightly but significantly affected in vivo by patients' cancer condition. Moreover, lipopolysaccharide stimulation of blood irradiated ex vivo led to a significant modification of CCNG1 and PHPT1 transcriptional response in a dose- and time-dependent manner with opposite regulatory effects. Curcumin also affected CCNG1 and PHPT1 transcriptional response counteracting some of the radiation induction. No differences were observed based on sex. Dose estimations calculated using linear regression were affected by lipopolysaccharide and curcumin. In conclusion, several confounding factors tested in this study can indeed modulate the transcriptional response of CCNG1 and PHPT1 and consequently can affect radiation exposure dose estimations but not to a level which should prevent the biomarkers' use for triage purposes.
Collapse
|
28
|
Ranger A, Dunlop A, Hutchinson K, Convery H, Maclennan MK, Chantler H, Twyman N, Rose C, McQuaid D, Amos RA, Griffin C, deSouza NM, Donovan E, Harris E, Coles CE, Kirby A. A Dosimetric Comparison of Breast Radiotherapy Techniques to Treat Locoregional Lymph Nodes Including the Internal Mammary Chain. Clin Oncol (R Coll Radiol) 2018; 30:346-353. [PMID: 29483041 DOI: 10.1016/j.clon.2018.01.017] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 01/02/2018] [Accepted: 01/03/2018] [Indexed: 10/17/2022]
Abstract
AIMS Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). MATERIALS AND METHODS In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. RESULTS One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). CONCLUSIONS Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics.
Collapse
|
29
|
Edmunds DM, Gothard L, Khabra K, Kirby A, Madhale P, McNair H, Roberts D, Tang KK, Symonds‐Tayler R, Tahavori F, Wells K, Donovan E. Low-cost Kinect Version 2 imaging system for breath hold monitoring and gating: Proof of concept study for breast cancer VMAT radiotherapy. J Appl Clin Med Phys 2018; 19:71-78. [PMID: 29536664 PMCID: PMC5978957 DOI: 10.1002/acm2.12286] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 11/12/2017] [Accepted: 01/09/2018] [Indexed: 11/30/2022] Open
Abstract
Voluntary inspiration breath hold (VIBH) for left breast cancer patients has been shown to be a safe and effective method of reducing radiation dose to the heart. Currently, VIBH protocol compliance is monitored visually. In this work, we establish whether it is possible to gate the delivery of radiation from an Elekta linac using the Microsoft Kinect version 2 (Kinect v2) depth sensor to measure a patient breathing signal. This would allow contactless monitoring during VMAT treatment, as an alternative to equipment-assisted methods such as active breathing control (ABC). Breathing traces were acquired from six left breast radiotherapy patients during VIBH. We developed a gating interface to an Elekta linac, using the depth signal from a Kinect v2 to control radiation delivery to a programmable motion platform following patient breathing patterns. Radiation dose to a moving phantom with gating was verified using point dose measurements and a Delta4 verification phantom. 60 breathing traces were obtained with an acquisition success rate of 100%. Point dose measurements for gated deliveries to a moving phantom agreed to within 0.5% of ungated delivery to a static phantom using both a conventional and VMAT treatment plan. Dose measurements with the verification phantom showed that there was a median dose difference of better than 0.5% and a mean (3% 3 mm) gamma index of 92.6% for gated deliveries when using static phantom data as a reference. It is possible to use a Kinect v2 device to monitor voluntary breath hold protocol compliance in a cohort of left breast radiotherapy patients. Furthermore, it is possible to use the signal from a Kinect v2 to gate an Elekta linac to deliver radiation only during the peak inhale VIBH phase.
Collapse
|
30
|
Wang H, Donovan E, Nisbet A, Alobaidli S, Phillips I, Ezhil V, Webster P, Ferreira M, Evans P. PO-0970: Robustness of Texture as a Biomarker in Radiomics Applications. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)31280-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
31
|
Ranger A, Perotti C, Dunlop A, Donovan E, McNair H, Harris E, Kirby A. EP-1283: Lung sparing techniques for internal mammary chain radiotherapy in right breast cancer patients. Radiother Oncol 2018. [DOI: 10.1016/s0167-8140(18)31593-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
32
|
O'Brien G, Cruz-Garcia L, Majewski M, Grepl J, Abend M, Port M, Tichý A, Sirak I, Malkova A, Donovan E, Gothard L, Boyle S, Somaiah N, Ainsbury E, Ponge L, Slosarek K, Miszczyk L, Widlak P, Green E, Patel N, Kudari M, Gleeson F, Vinnikov V, Starenkiy V, Artiukh S, Vasyliev L, Zaman A, Badie C. FDXR is a biomarker of radiation exposure in vivo. Sci Rep 2018; 8:684. [PMID: 29330481 PMCID: PMC5766591 DOI: 10.1038/s41598-017-19043-w] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 12/20/2017] [Indexed: 11/29/2022] Open
Abstract
Previous investigations in gene expression changes in blood after radiation exposure have highlighted its potential to provide biomarkers of exposure. Here, FDXR transcriptional changes in blood were investigated in humans undergoing a range of external radiation exposure procedures covering several orders of magnitude (cardiac fluoroscopy, diagnostic computed tomography (CT)) and treatments (total body and local radiotherapy). Moreover, a method was developed to assess the dose to the blood using physical exposure parameters. FDXR expression was significantly up-regulated 24 hr after radiotherapy in most patients and continuously during the fractionated treatment. Significance was reached even after diagnostic CT 2 hours post-exposure. We further showed that no significant differences in expression were found between ex vivo and in vivo samples from the same patients. Moreover, potential confounding factors such as gender, infection status and anti-oxidants only affect moderately FDXR transcription. Finally, we provided a first in vivo dose-response showing dose-dependency even for very low doses or partial body exposure showing good correlation between physically and biologically assessed doses. In conclusion, we report the remarkable responsiveness of FDXR to ionising radiation at the transcriptional level which, when measured in the right time window, provides accurate in vivo dose estimates.
Collapse
|
33
|
Qu M, Velker V, Leung E, Kwon J, Elshaikh M, Kong I, Logie N, Mendez L, van der Putten L, Donovan E, Munkarah A, Wiebe E, Louie A, D'Souza D. Improved Disease Control With Adjuvant Therapy for Stage IA Serous and Clear Cell Uterine Cancer: A Pooled Multi-institutional Analysis. Int J Radiat Oncol Biol Phys 2017. [DOI: 10.1016/j.ijrobp.2017.06.563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
34
|
Kovochich M, Fung ES, Donovan E, Unice KM, Paustenbach DJ, Finley BL. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions. J Biomed Mater Res B Appl Biomater 2017; 106:986-996. [PMID: 28480531 DOI: 10.1002/jbm.b.33902] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 03/14/2017] [Accepted: 04/03/2017] [Indexed: 12/12/2022]
Abstract
Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (<100 nm) to submicron (<1000 nm) size range, whereas edge-loading conditions generated particles that ranged from <100 nm up to 3000-6000 nm in size. Particles isolated from normal wear were primarily chromium (98.5%) and round to oval in shape. Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018.
Collapse
|
35
|
Ranger A, Dunlop A, Maclennan M, Donovan E, Harris E, Brigden B, Knowles C, Carr K, Henegan E, Francis J, Bartlett F, Somiah N, Locke I, Coles C, Kirby A. OC-0452: Evaluation of a novel field placement algorithm for tangential internal mammary chain radiotherapy. Radiother Oncol 2017. [DOI: 10.1016/s0167-8140(17)30894-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
36
|
Donovan E, Timotin E, Farrell T, Donde B, Puksa S, Sur R. Endobronchial brachytherapy for metastasis from extrapulmonary malignancies as an effective treatment for palliation of symptoms. Brachytherapy 2017; 16:630-638. [PMID: 28202343 DOI: 10.1016/j.brachy.2017.01.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 12/20/2016] [Accepted: 01/09/2017] [Indexed: 02/07/2023]
Abstract
PURPOSE Endobronchial metastasis (EBM) originating from primary cancers outside the lung is rare. External beam radiotherapy is often attempted for control of symptoms with variable effectiveness and retreatment is challenging if symptoms recur. There is limited documentation of high-dose-rate brachytherapy for EBM in the literature. METHODS AND MATERIALS A prospective database was created from 2006 to 2015. Patients with EBM who received high-dose-rate brachytherapy were included. Cough, dyspnea, chest pain, and hemoptysis were assessed and graded (0-4) at the time of initial consult and in followup. Symptom-free survival and re-expansion were assessed. RESULTS Thirty-five patients with EBM were identified. Most patients received three fractions of 700 cGy, and 17 patients had prior external beam radiotherapy. Median symptom-free and overall survival were 67 and 117 days. After brachytherapy, improvement in cough was documented in 75.0%, hemoptysis in 76.4%, dyspnea in 60.0% for a median of 3-6 months. Of the 22 patients who had subsequent chest imaging, re-expansion was documented in 32%. There were no significant toxicities reported. CONCLUSIONS Brachytherapy appears effective in achieving durable symptom control of cough hemoptysis, and dyspnea in patients with EBM and should be considered routinely for palliation where available. Further studies are required to better characterize expected symptom improvement, lung re-expansion rates, and efficacy in comparison with other local treatments.
Collapse
|
37
|
Landeg SJ, Kirby AM, Lee SF, Bartlett F, Titmarsh K, Donovan E, Griffin CL, Gothard L, Locke I, McNair HA. A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy. Br J Radiol 2016; 89:20160288. [PMID: 27710100 PMCID: PMC5604906 DOI: 10.1259/bjr.20160288] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 09/22/2016] [Accepted: 09/29/2016] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVE The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. METHODS In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σsetup) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. RESULTS 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σsetup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. CONCLUSION UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial.
Collapse
|
38
|
Winans B, Tvermoes BE, Unice KM, Kovochich M, Fung ES, Christian WV, Donovan E, Finley BL, Kimber I, Paustenbach DJ. Data on the histological and immune cell response in the popliteal lymph node in mice following exposure to metal particles and ions. Data Brief 2016; 9:388-97. [PMID: 27689127 PMCID: PMC5035236 DOI: 10.1016/j.dib.2016.08.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 08/17/2016] [Accepted: 08/22/2016] [Indexed: 11/26/2022] Open
Abstract
Hip implants containing cobalt–chromium (CoCr) have been used for over 80 years. In patients with metal-on-metal (MoM) hip implants, it has been suggested that wear debris particles may contribute to metal sensitization in some individuals, leading to adverse reactions. This article presents data from a study in which the popliteal lymph node assay (PLNA) was used to assess immune responses in mice treated with chromium-oxide (Cr2O3) particles, metal salts (CoCl2, CrCl3, and NiCl2) or Cr2O3 particles with metal salts (“A preliminary evaluation of immune stimulation following exposure to metal particles and ions using the mouse popliteal lymph node assay” (B.E. Tvermoes, K.M. Unice, B. Winans, M. Kovochich, E.S. Fung, W.V. Christian, E. Donovan, B.L. Finley, B.L. Kimber, I. Kimber, D.J. Paustenbach, 2016) [1]). Data are presented on (1) the chemical characterization of TiO2 particles (used as a particle control), (2) clinical observations in mice treated with Cr2O3 particles, metal salts or Cr2O3 particles with metal salts, (3) PLN weight and weight index (WI) in mice treated with Cr2O3 particles, metal salts or Cr2O3 particles with metal salts, (4) histological changes in PLNs of mice treated with Cr2O3 particles, metal salts or Cr2O3 particles with metal salts, (5) percentages of immune cells in the PLNs of mice treated with Cr2O3 particles, metal salts or Cr2O3 particles with metal salts, and (6) percentages of proliferating cells in the PLNs of mice treated with Cr2O3 particles, metal salts or Cr2O3 particles with metal salts.
Collapse
|
39
|
Edmunds D, Donovan E. SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy. Med Phys 2016. [DOI: 10.1118/1.4957111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
40
|
Landeg S, Kirby A, Lee S, Bartlett F, Donovan E, Locke I, Gothard L, Boyle S, Titmarsh K, Griffin C, McNair H. PO-0782: Breast radiotherapy: invisible tattoos for external references (The BRITER study). Radiother Oncol 2015. [DOI: 10.1016/s0167-8140(15)40774-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
41
|
Forsyth C, Fazakerley AN, Rae IJ, J Watt CE, Murphy K, Wild JA, Karlsson T, Mutel R, Owen CJ, Ergun R, Masson A, Berthomier M, Donovan E, Frey HU, Matzka J, Stolle C, Zhang Y. In situ spatiotemporal measurements of the detailed azimuthal substructure of the substorm current wedge. JOURNAL OF GEOPHYSICAL RESEARCH. SPACE PHYSICS 2014; 119:927-946. [PMID: 26167439 PMCID: PMC4497475 DOI: 10.1002/2013ja019302] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Accepted: 01/13/2014] [Indexed: 06/01/2023]
Abstract
UNLABELLED The substorm current wedge (SCW) is a fundamental component of geomagnetic substorms. Models tend to describe the SCW as a simple line current flowing into the ionosphere toward dawn and out of the ionosphere toward dusk, linked by a westward electrojet. We use multispacecraft observations from perigee passes of the Cluster 1 and 4 spacecraft during a substorm on 15 January 2010, in conjunction with ground-based observations, to examine the spatial structuring and temporal variability of the SCW. At this time, the spacecraft traveled east-west azimuthally above the auroral region. We show that the SCW has significant azimuthal substructure on scales of 100 km at altitudes of 4000-7000 km. We identify 26 individual current sheets in the Cluster 4 data and 34 individual current sheets in the Cluster 1 data, with Cluster 1 passing through the SCW 120-240 s after Cluster 4 at 1300-2000 km higher altitude. Both spacecraft observed large-scale regions of net upward and downward field-aligned current, consistent with the large-scale characteristics of the SCW, although sheets of oppositely directed currents were observed within both regions. We show that the majority of these current sheets were closely aligned to a north-south direction, in contrast to the expected east-west orientation of the preonset aurora. Comparing our results with observations of the field-aligned current associated with bursty bulk flows (BBFs), we conclude that significant questions remain for the explanation of SCW structuring by BBF-driven "wedgelets." Our results therefore represent constraints on future modeling and theoretical frameworks on the generation of the SCW. KEY POINTS The substorm current wedge (SCW) has significant azimuthal structureCurrent sheets within the SCW are north-south alignedThe substructure of the SCW raises questions for the proposed wedgelet scenario.
Collapse
|
42
|
Coles CE, Donovan E, Haviland J, Yarnold J. Intensity-modulated Radiotherapy for the Treatment of Breast Cancer. Clin Oncol (R Coll Radiol) 2013; 25:215. [PMID: 23207073 DOI: 10.1016/j.clon.2012.11.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2012] [Accepted: 11/06/2012] [Indexed: 10/27/2022]
|
43
|
Ge YS, Zhou XZ, Liang J, Raeder J, Gilson ML, Donovan E, Angelopoulos V, Runov A. Dipolarization fronts and associated auroral activities: 1. Conjugate observations and perspectives from global MHD simulations. ACTA ACUST UNITED AC 2012. [DOI: 10.1029/2012ja017676] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
44
|
Nishimura Y, Lyons LR, Kikuchi T, Angelopoulos V, Donovan E, Mende S, Chi PJ, Nagatsuma T. Formation of substorm Pi2: A coherent response to auroral streamers and currents. ACTA ACUST UNITED AC 2012. [DOI: 10.1029/2012ja017889] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
45
|
Donovan E, Sahmel J, Scott P, Paustenbach D. Response to a letter to the Editor by Dr. David Egilman and Mr. John Schilling regarding the article by Donovan et al. (2011). Crit Rev Toxicol 2012; 42:173-183. [PMID: 26479716 DOI: 10.3109/10408444.2011.644506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
46
|
Agrawal RK, Alhasso A, Barrett-Lee PJ, Bliss JM, Bliss P, Bloomfield D, Bowen J, Brunt AM, Donovan E, Emson M, Goodman A, Harnett A, Haviland JS, Kaggwa R, Morden JP, Robinson A, Simmons S, Stewart A, Sydenham MA, Syndikus I, Tremlett J, Tsang Y, Wheatley D, Venables K, Yarnold JR. First results of the randomised UK FAST Trial of radiotherapy hypofractionation for treatment of early breast cancer (CRUKE/04/015). Radiother Oncol 2011; 100:93-100. [PMID: 21752481 DOI: 10.1016/j.radonc.2011.06.026] [Citation(s) in RCA: 172] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2011] [Revised: 06/10/2011] [Accepted: 06/11/2011] [Indexed: 12/24/2022]
Abstract
BACKGROUND AND PURPOSE Randomised trials testing 15- or 16-fraction regimens of adjuvant radiotherapy in women with early breast cancer have reported favourable outcomes compared with standard fractionation. To evaluate hypofractionation further, two 5-fraction schedules delivering 1 fraction per week have been tested against a 25-fraction regimen. MATERIALS AND METHODS Women aged ⩾50years with node negative early breast cancer were randomly assigned after microscopic complete tumour resection to 50Gy in 25 fractions versus 28.5 or 30Gy in 5 once-weekly fractions of 5.7 or 6.0Gy, respectively, to the whole breast. The primary endpoint was 2-year change in photographic breast appearance. RESULTS Nine hundred and fifteen women were recruited from 2004 to 2007. Seven hundred and twenty-nine patients had 2-year photographic assessments. Risk ratios for mild/marked change were 1.70 (95% CI 1.26-2.29, p<0.001) for 30Gy and 1.15 (0.82-1.60, p=0.489) for 28.5Gy versus 50Gy. Three-year rates of physician-assessed moderate/marked adverse effects in the breast were 17.3% (13.3-22.3%, p<0.001) for 30Gy and 11.1% (7.9-15.6%, p=0.18) for 28.5Gy compared with 9.5% (6.5-13.7%) after 50Gy. With a median follow-up in survivors of 37.3months, 2 local tumour relapses and 23 deaths have occurred. CONCLUSIONS At 3years median follow-up, 28.5Gy in 5 fractions is comparable to 50Gy in 25 fractions, and significantly milder than 30Gy in 5 fractions, in terms of adverse effects in the breast.
Collapse
|
47
|
|
48
|
Trouncer R, Thomas M, Blasiak-Wal I, Donovan E. A Simple Planning Software Model to Account for Linac Couch Attenuation. Clin Oncol (R Coll Radiol) 2011. [DOI: 10.1016/j.clon.2011.01.494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
49
|
Kubyshkina M, Sergeev V, Tsyganenko N, Angelopoulos V, Runov A, Donovan E, Singer H, Auster U, Baumjohann W. Time-dependent magnetospheric configuration and breakup mapping during a substorm. ACTA ACUST UNITED AC 2011. [DOI: 10.1029/2010ja015882] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
50
|
Morioka A, Miyoshi Y, Miyashita Y, Kasaba Y, Misawa H, Tsuchiya F, Kataoka R, Kadokura A, Mukai T, Yumoto K, Menietti DJ, Parks G, Liou K, Honary F, Donovan E. Two-step evolution of auroral acceleration at substorm onset. ACTA ACUST UNITED AC 2010. [DOI: 10.1029/2010ja015361] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|